Complete Product Range

Becker Pumps Corp.


100 East Ascot Lane
Cuyahoga Falls, Ohio 44223-3768

Ph.: 330-928-9966
Fx.: 330-928-7065
Toll free: 888-633-1083

www.beckerpumps.com
info@beckerpumps.com
BECKER VACUUM PUMPS, COMPRESSORS, REGENERATIVE BLOWERS,
RADIAL BLOWERS, ROTARY SCREW PUMPS, and CENTRAL SYSTEMS

Becker's USA headquarters


in Cuyahoga Falls, Ohio

WHY BECKER?
EXPERIENCE
Becker, founded in 1885, has been Low pressure oil-less compres-
making vacuum pumps longer than sors, for operation to 25 PSIG.
most other pump manufacturers Single and two stage regenera-
currently on the market. We were tive blowers, with or without
the first to develop several tech- variable speed control. Oil-less,
nologies that are today's standards. of course.
It is on this experience from which Central vacuum systems in both
we draw when applying the correct 100% oil-less and oil-flooded
product for your application. designs. General industrial, and
industry-specific designs for
FLEXIBILITY medical/surgical, waste anesthet-
Look no Becker manufactures vacuum
pumps in a number of basic
ic gas disposal, and router table
hold down are available.
further than designs that can fit your needs
exactly. No longer do you have to HIGH QUALITY
Becker for settle for a pump that is a compro- Becker is ISO 9001 certified, the
the solution mise. Our product line includes:
100% Oil-less vacuum pumps,
highest international quality level
attainable. In addition, all Becker
to your capable of operation to 27" HgV,
depending on model.
pumps are CE compliant.

problems Oil-flooded vacuum pumps, for SALES and SERVICE


operation to 29.83 in. HgV (2 Becker has a nationwide network
torr abs.) with the SA version, of sales offices and service cen-
or 29.9 in. HgV (0.4 torr abs.) ters. Chances are, we have some-
with the F version. one near you.
Combined pressure/vacuum
pumps, capable of operation to You need to look no further than
9 PSIG and 18" HgVsimulta- Becker for the solution to your
neously! problems.
Rotary Vane Oil-less Vacuum Pumps

100% Oil-less operation


Quiet
Cool operation
Long vane life
Inlet filters included
Discharge silencers
Direct drive
Vacuum regulators included
Minimal maintenance
Continuous duty rated

CFM Max. Cont. Wt.


MODEL Open Flow Vacuum (in. Hg) HP/kW (lbs.)
VT 4.4 2.8 25.5 0.3/0.22 15

DRY
VT 4.8 5.6 25.5 0.56/0.45 24
VT 4.10 7.1 25 0.6/0.45 35
VT 4.16 11 25 0.94/0.7 50
VT 4.25 K 18 25 1.2/0.9 57
VT 4.40 K 28 25 2/1.5 85
KVT 3.60 39 27 3/2.2 151
KVT 3.80 48 27 5/3.6 178
KVT 3.100 69 27 5/3.6 230
KVT 3.140 95 22 7.5/5.6 320
VTLF 200 130 25 7.5/5.6 865
VTLF 250 SK 173 25 10/7.5 865
VTLF 400 280 22.5 18/13.2 1090
VTLF 500 SK 353 22.5 24/18 1100

4
Rotary Vane Oil-less Compressors

100% Oil-less operation


Quiet
Cool operation
Aftercooler included (K models)
Direct drive
Long vane life
Inlet filter standard
Pressure regulator included
Minimal maintenance
Continuous duty rated

CFM Max. Cont. Wt.


MODEL Open Flow Pressure (PSIG) HP/kW (lbs.)
DT 4.4 2.8 15 0.3/0.22 15

DRY
DT 4.8 5.6 15 0.56/0.45 24
DT 4.10 7.1 15 0.6/0.45 35
DT 4.16 11 15 0.94/0.7 52
DT 4.25 K 18 15 1.75/1.3 68
DT 4.40 K 28 15 2.9/2.2 70
KDT 3.60 39 22 5/3.6 191
KDT 3.80 48 22 7.5/5.6 265
KDT 3.100 69 22 10/7.5 323
KDT 3.140 95 22 12/9 368
DTLF 200 130 25 15/11.2 902
DTLF 250 173 25 20/15 902
DTLF 400 280 25 30/22 1265
DTLF 500 353 25 48/36 1320
Variair Rotary Vane Vacuum Pumps

Patented intelligent variable speed controller


100% Oil-less operation
Quiet
Compact
Extended vane life
5:2 flow ratio
Integrated inlet filters
Minimal maintenance
Maintains constant pressure

DRY
CFM Range Max. Vacuum Wt.
MODEL* Open Flow (In. Hg) HP/kW (lbs.)
VAU VT 4.40/0-400 1228 25 ** 93
VAU KVT 3.100/0-400 2969 27 ** 232
VAU KVT 3.140/0-400 4095 22 ** 260
VAU VTLF 250/0-400 73173 25 ** 765
* Models are voltage specific. Contact factory for availability.
** Contact factory for details

6
Variair Rotary Vane Compressors

Patented intelligent variable speed controller


100% Oil-less operation
Quiet
Extended vane life
Compact
5:2 flow ratio
Integrated inlet filters
Maintains constant pressure
Minimal maintenance

DRY
CFM Range Max. Pressure Wt.
MODEL* Open Flow (PSIG) HP/kW (lbs.)
VAU DT 4.40/0-400 1228 15 ** 108
VAU KDT 3.80/0-400 2048 22 ** 197
VAU KDT 3.140/0-400 4095
73173 2522 10.2/7.5
** 325
772
VAU DTLF 250/0-400 73173 25 ** 920
* Models are voltage specific. Contact factory for availability.
** Contact factory for details
Rotary Vane Oil-less Combined Vacuum & Pressure Pumps

100% Oil-less operation


Quiet
Direct drive
No need to purchase separate pumps for vacuum and pres-
sure for the same application.
Adjust vacuum flow and pressure flow simultaneously with
the ability to adjust either without loss of performance.
Separate inlet filters for each port
Vacuum and pressure regulators included
Minimal maintenance

CFM Max. Vac. Max. Pr. Wt.


MODEL Open Flow (In. Hg)* (PSIG)* HP/kW (lbs.)
T 4.16 DS 11 18 9 0.9/0.7 53

DRY
T 4.25 DSK 18 18 9 1.7/1.3 77
T 4.40 DSK 28 18 9 2.7/2 99
DVT 3.60 39 18 9 5/3.6 175
DVT 3.80 48 18 9 5/3.6 240
DVT 3.100 69 18 9 7.5/5.5 306
DVT 3.140 95 18 9 10/7.5 392
DVTLF 250 SK 173 15 7 15/11 902

Dual Vacuum with Pressure


DVT 3.80 R 48 15/12 9 5/3.6 241
DVT 3.100 R 69 15/12 9 7.5/5.5 306
DVT 3.140 R 95 15/12 9 10/7.5 393
* Maximum vacuum and pressure when operated simultaneously. Contact factory for other conditions.

8
Rotary Vane Oil-Flooded Vacuum Pumps

Vacuum to 29.9 in. Hg (0.4 Torr)


Quiet
Highly efficient
Compact
Direct drive
Semi-synthetic oil standard
Gas ballast optional
Cool running
Multi-stage oil separation system99.9+% efficient

CFM Ultimate Pressure Wt.


MODEL Open Flow (Torr/In. Hg*) HP/kW (lbs.)
U 3.6 SA 4.6 2/29.84 0.4/0.3 33
U 4.20 12.4 0.7/29.9 0.9/0.7 44
U 4.40 28.8 0.7/29.9 2.4/1.8 84
U 4.70 SA 49 2/29.84 3/2.2 119
U 4.70 F 49 0.4/29.9 3/2.2 119
U 4.100 SA 71 2/29.84 5/3.6 170
U 4.100 F 71 0.4/29.9 5/3.6 170
U 4.165 SA 113 2/29.84 5/3.6 302
3.6 SAF
U 4.165 11
113 18 0.4/29.9 9 0.9/0.25
5/3.6 53
302
U 4.190 SA 129 2/29.84 7.5/5.5 371
U 4.190 F 129 0.4/29.9 7.5/5.5 371
U 4.250 SA 168 2/29.84 10/7.5 415
U 4.250 F 168 0.4/29.9 10/7.5 415
U 4.400 SA 290 2/29.84 15/11 1125
U 4.400 F 290 0.4/29.9 15/11 1125
U 4.630 250
DVTLF SA SK 440
173 18 2/29.84 9 25/18.7
15/11 1300
x
U 4.630 250
DVTLF F SK 440
173 18 0.4/29.9 9 25/18.7
15/11 1300
x
* Based on standard barometric pressure of 29.92 in. Hg
Regenerative Single Stage Blowers for Vacuum

100% Oil-less operation


Quiet
Compact
High performance
Integrated inlet filter (7 & 8 series)
Integrated vacuum relief valve (7 & 8 series)
Contact-less
Minimal maintenance
Convertible to two stage operation

CFM Max. Vacuum Wt.


MODEL Open Flow (In. H2O) HP*/kW (lbs.)
SV 5.90/1 55 45 0.6/0.45 29

DRY
SV 8.130/1 86 90 0.9/0.7 60
SV 8.160/1 100 68 2.4/1.8 60
SV 8.190/1 128 112 3/2.2 75
SV 5.250/1 148 61 2.4/1.8 86
SV 5.300/1 232 142 8.8/6.6 196
SV 7.330/1 200 108 6.4/4.8 88
SV 8.400/1 295 129 8.8/6.6 176
U 3.6
SV SA
7.430/1 11
294 18 90 9 0.9/0.25
6.4/4.8 53
88
SV 5.490/1 335 108 12/9 209
SV 5.690/1 527 106 17.6/13.2 242
SV 5.1050/1 736 122 20/15 282
* Models are available with smaller HP motors for applications requiring less capacity. Contact factory.

10
Regenerative Two Stage Blowers for Vacuum

100% Oil-less operation


Quiet
Compact
High performance
Integrated inlet filter (7 & 8 series)
Integrated vacuum relief valve (7 & 8 series)
Contact-less
Minimal maintenance
Convertible to single stage operation

CFM Max. Vacuum Wt.


MODEL Open Flow (In. H2O) HP*/kW (lbs.)
SV 5.90/2 29 102 0.6/0.45 29

DRY
SV 8.130/2 44 140 0.9/0.7 63
SV 8.160/2 56 130 2.4/1.8 63
SV 8.190/2 69 150 3/2.2 78
SV 5.250/2 94 128 2.4/1.8 86
SV 7.330/2 109 160 4.8/3.6 88
SV 8.400/2 150 171 8.8/6.6 180
SV 7.430/2 173 120 6.4/4.8 88
U 3.6
SV SA
5.690/2 11
251 18 114 9 0.9/0.25
10/7.5 53
211
* Models are available with smaller HP motors for applications requiring less capacity. Contact factory.
Regenerative Single Stage Blowers for Pressure

100% Oil-less operation


Quiet
Compact
High performance
Integrated inlet filter (7 & 8 series)
Integrated pressure relief valve (7 & 8 series)
Contact-less
Minimal maintenance
Convertible to two stage operation

CFM Max. Pressure Wt.


MODEL Open Flow (In. H2O) HP*/kW (lbs.)
SV 5.90/1 55 47 0.6/0.45 29

DRY
SV 8.130/1 86 90 0.9/0.7 60
SV 8.160/1 100 68 2.4/1.8 60
SV 8.190/1 128 102 3/2.2 75
SV 5.250/1 148 53 2.4/1.8 86
SV 5.300/1 232 161 8.8/6.6 196
SV 7.330/1 200 146 6.4/4.8 88
SV 8.400/1 295 97 8.8/6.6 176
U 3.6
SV SA
7.430/1 11
294 18 84 9 0.9/0.25
6.4/4.8 53
88
SV 5.490/1 335 148 12/9 209
SV 5.690/1 527 158 17.6/13.2 242
SV 5.1050/1 736 122 20/15 282
* Models are available with smaller HP motors for applications requiring less capacity. Contact factory.

12
Regenerative Two Stage Blowers for Pressure

100% Oil-less operation


Quiet
Compact
High performance
Integrated inlet filter (7 & 8 series)
Integrated pressure relief valve (7 & 8 series)
Contact-less
Minimal maintenance
Convertible to single stage operation

CFM Max. Pressure Wt.


MODEL Open Flow (In. H2O) HP*/kW (lbs.)
SV 5.90/2 29 96 0.6/0.45 29

DRY
SV 8.130/2 44 160 0.9/0.7 63
SV 8.160/2 56 126 2.4/1.8 63
SV 8.190/2 69 200 3/2.2 78
SV 5.250/2 94 130 2.4/1.8 86
SV 7.330/2 109 200 4.8/3.6 88
SV 8.400/2 150 236 8.8/6.6 180
SV 7.430/2 173 160 6.4/4.8 88
U 3.6
SV SA
5.690/2 11
251 18 144 9 0.9/0.25
10/7.5 53
211
* Models are available with smaller HP motors for applications requiring less capacity. Contact factory.
Variair Regenerative Blowers for Vacuum

100% Oil-less operation


Patented intelligent variable speed controller
20:1 flow ratio
Quiet
Compact
High performance
Integrated inlet filter
Contact-less
Minimal maintenance
Maintains constant vacuum level

DRY
Max. CFM Max. Vacuum Wt.
MODEL* Open Flow (In. H2O) HP/kW (lbs.)
VAU SV 8.130/1-401 135 100 ** 70
VAU SV 7.190/1-401 204 94 ** 72
1-Stage VAU SV 8.190/1-401 ** ** ** **
VAU SV 7.330/1-401 304 132 ** 133
VAU SV 8.400/1-401 460 136 ** **

VAU SV 8.130/2-401 76 153 ** 72


VAU SV 7.190/2-401 109 167 ** 77
2-Stage U 3.6SV
VAU SA8.190/2-401 11 ** 18 ** 9 0.9/0.25
** 53
**
VAU SV 7.330/2-401 171 181 ** 134
VAU SV 8.400/2-401 240 155 ** **
* Inverter is voltage specific. Contact factory for availability.
** Contact factory for details

14
Variair Regenerative Blowers for Pressure

100% Oil-less operation


Patented intelligent variable speed controller
20:1 flow ratio
Quiet
Compact
High performance
Integrated inlet filter
Contact-less
Minimal maintenance
Maintains constant pressure

DRY
Max. CFM Max. Pressure Wt.
MODEL* Open Flow (In. H2O) HP/kW (lbs.)
VAU SV 8.130/1-401 135 141 ** 70
VAU SV 7.190/1-401 204 92 ** 72
1-Stage VAU SV 8.190/1-401 ** ** ** **
VAU SV 7.330/1-401 304 155 ** 133
VAU SV 8.400/1-401 460 146 ** **

VAU SV 8.130/2-401 76 221 ** 72


VAU SV 7.190/2-401 109 181 ** 77
2-Stage U 3.6SV
VAU SA8.190/2-401 11 ** 18 ** 9 0.9/0.25
** 53
**
VAU SV 7.330/2-401 171 221 ** 134
VAU SV 8.400/2-401 240 250 ** **
* Inverter is voltage specific. Contact factory for availability.
** Contact factory for details
Rotary Dry Screw Vacuum Pumps and Compressors

Dry operation
Direct drive - No drive transmission
Variable speed controlled
2:1 speed regulation
Sound enclosure standard

DRY
CFM Range Max. Vac. Max. Pr. Wt.
MODEL Open Flow (In. Hg) (PSIG) HP/kW (lbs.)
VADS 650 190340 22 25/18.7 992
Vacuum
VADS 1500 460840 24 50/38 2318

VADS 650 190340 15 30/22.5 992


Pressure
VADS 1500 460840 15 60/45 2318

16
Radial Blowers for Vacuum or Pressure

Integrated intelligent variable speed controller


Quiet
Non-metallic housing
Compact
High flow/low pressure operation

DRY
CFM Range Max. Vac. Max. Pr. Wt.
MODEL Open Flow (In. H2O) (In. H2O) HP/kW (lbs.)
Vacuum RV 1.3233/10 5201062 23 5.33/4 88

Pressure RV 1.3233/10 5201062 23 5.33/4 88


Rotary Vane Central Vacuum Systems

Tank mounted or modular/expandable arrangements


Field expandable up to six pumps
Compact
Automatic alternating and cascading controls
Most models fit through 36" doorway
18 to over 2600 CFM capacities

Advantage-D
Advantage-D systems are 100% oil-less central vacuum systems for medical/surgical or general industrial applications that
require operating vacuum levels from atmosphere to as high as 27 in. Hg. These applications are typically those that involve
air or inert gases, or moderate amounts of water vapor. Medical/surgical systems meet current NFPA 99 requirements.

Advantage-L
Advantage-L systems employ our "U" series oil-flooded pumps for those applications that require operation at higher vacuum
levels, up to 29.9 in. Hg (0.5 torr). These applications include medical/surgical, laboratory, material handling, and other indus-
trial processes. Available NFPA 99 compliant for medical/surgical use.

Advantage-A
Advantage-A systems are specially designed for use with waste anesthetic gas disposal applications, or those with higher
than normal oxygen concentrations. These systems use specially modified versions of our dry pumps that have been pre-
pared for oxygen use by meticulous hydrocarbon degreasing and using totally inert grease in the bearings. As with our
Advantage-D and L systems, these are available in a wide range of capacities and are NFPA 99 compliant.

Advantage-W
Advantage-W systems are specifically designed to meet the requirements of manufacturers that use vacuum hold-down for
router tables in the woodworking and other related industries. They are available in duplex or triplex designs, and can be
supplied with up to triple the normal inlet filtration to ensure clean air and long pump life, and to minimize filter maintenance.

18 Ask your Becker salesperson for a central vacuum system catalog, today!
Call 888-633-1083
Becker Pumps Corp. 100 East Ascot Lane Cuyahoga Falls, Ohio 44223-3768
330-928-9966 Fx.: 330-928-7065 Toll free: 888-633-1083 www.beckerpumps.com info@beckerpumps.com