DC/DC CONVERTERS WK302824/28S-150

28V NOMINAL INPUT 150WATTS

FEATURES
50V/50ms Transient Voltage MODELS
18VDC ~ 36VDC Permit Input OUTPUT VOLTAGE (VDC)
150W Output Power
Sync Function, Inhibit Function SINGLE
Over Current/Short Circuit Protection 24
Optocoupler Feedback 28
Remote Sense on Single Output Models

DESCRIPTION
The WK302824/28S-150 Model of high-frequency applications. Units are available with standard
DC/DC converters offers ruggedness, reliability and screening, and fully compliant with class E/M
features required to meet the design challenges of screening.
high reliability market. WK302824/28S-150Model The input filter circuit is designed to reduce
utilizes hybrid integration technology and all-metal electro-magnetic interference. The typical input
hermetic enclosure. This Model provides up to 150 voltage is 28V, and ranges from 18V to 36V. The
watts output power over the full temperature range modules can withstand 50V/50ms input surge
of -55 to +105C with up to 85% efficiency. voltage. The WK302824/28S-150 Model also
The WK302824/28S-150 Model small size, low provides some functions such as synchronization
height, and hermetically sealed metal enclosures (Sync), inhibit and over current /short circuit
make them ideal for use in military, protection.
aerospace/aviation and with other high reliability

FUNCTIONAL BLOCK DIAGRAM

ABSOLUTE MAXIMUM RATINGS


Input Voltage Transient: 50VDC /50ms
Operating Temp(Tc): -55C ~ +105C (M)/-40C ~ +85C (E/I)
Storage Temp: -55C ~ +125C (M/E/I)
Pin-Solder Temp (10s): 300C

Weiking Electronics Manufacturing (Xian) Co.,Ltd


Tel: +86-65660060-652 Fax: +86-65660061 E-mail:sales@weiking.com http://www.weiking.com
V1.0 2015.11.9
DC/DC CONVERTERS WK302824/28S-150
28V NOMINAL INPUT 150WATTS

ELECTRICAL CHARACTERISTICS
WK302824S-150 WK302828S-150
PARAMETERS CONDITIONS1) UNITS
MIN TYP MAX MIN TYP MAX
OUTPUT VOLTAGE VIN=18VDC ~ 36VDC 23.52 24.00 24.48 27.44 28.00 28.56 V
OUTPUT CURRENT VIN=28VDC 0 - 6.25 0 - 5.35 A
VIN=28VDC 20MHz
OUTPUT - 30 80 - 50 100 mVp-p
FULL LOAD
RIPPLE VOLTAGE2)
MIN TO MAX TC - - 150 - - 200 mVp-p
VIN=18VDC ~ 36VDC - 40 80 - 40 80
LINE REGULATION mV
MIN TO MAX TC - - 120 - - 120
VIN=28VDC
NO LOAD TO FULL - 100 200 - 100 200
LOAD REGULATION LOAD mV
MIN TO MAX TC - - 300 - - 300
CONTINUOUS 18 28 36 18 28 36
INPUT VOLTAGE V
50V/50ms3) - - 50 - - 50
NO LOAD - 30 100 - 50 100 mA
FULL LOAD
INPUT CURRENT - 6.3 - - 6.5 - A
VIN=28VDC
INHIBITED - 5 20 - 5 20 mA
SHORT CIRCUIT
SHORT CIRCUIT TIME - - 10 - - 10 s
PROTECTION
EFFICIENCY VIN=28VDC 81 85 - 79 83 - %

STEP LOAD RESPONSE - 1200 2400 - 1400 2800 mV


VIN=28VDC
STEP LOAD RESPONSE 50% ~ 100% ~ 50%
- 250 500 - 250 500 s
RECOVERY4)
DELAY - 35 100 - 35 100 ms
FULL LOAD
START-UP - 0 200 - 0 200 mVpk
OVERSHOOT
NO LOAD
- - 400 - - 400 mVpk
OVERSHOOT
GROUND FIXED
MTBF - 550 - - 550 - KHrs
Tc=25C

INSULATION RESISTANCE 100M@500VDC(INPUT-OUTPUT; INPUT-CASE; OUTPUT-CASE)

NOTES
1) Unless otherwise specified, Tc=25C, Vin=28 VDC , 100% load.
2) Using tip and barrel measurement.
3) Guaranteed by design.
4) Recovery time is measured from application of the transient to point at which VOUT is within 1% of VOUT at final value, transition time >
25s.

Weiking Electronics Manufacturing (Xian) Co.,Ltd


Tel: +86-65660060-652 Fax: +86-65660061 E-mail:sales@weiking.com http://www.weiking.com
V1.0 2015.11.9
DC/DC CONVERTERS WK302824/28S-150
28V NOMINAL INPUT 150WATTS

TYPICAL PERFORMANCE CURVES

WK302824S-150:

1Start--Up 2Step Load Response(50% to 100%) 3Output Ripple Voltage(20MHz)

APPLICATION NOTES

DC/DC Converter Typical Connection Shown as Below

Ci: large capacitanceSuggest at least 10uF


CoCo1Co2)10nF to 100nF ceramic, must be mounted as close as possible to the load.

Inhibit Function

The INH pin can be used as an external shut down for applications requiring on/off operation.
A logic pulled low (0 to 0.3V) on INH pin disables the converter.
No connection on INH pin enables the converter.

Over Current/Short Circuit Protection


The WK302824/28S-150 model of DC/DC converters has over current/short circuit protection. When it is
working under load fault condition, the converter will automatically activate the over current/short circuit
protection and restore when the fault is removed.
Caution: The duration of the over current/short circuit must be less than 10s, and the case temperature lower
than 105C, Otherwise, the module may be damaged.

Remote Sensing (Available On Single Output Models Only)


Remote sense allows the user to compensate for voltage drop between the output of the converter and
the point of regulation. The total voltage which may be compensated for is 0.5v in both leads (+) and (-). Mark
the connection to the regulation point within 1.2 meters of the converter output terminal.
If remote sense will be used, connect pin 10 to pin 7 and pin 9 to pin 8 or the output voltage will increase.
Weiking Electronics Manufacturing (Xian) Co.,Ltd
Tel: +86-65660060-652 Fax: +86-65660061 E-mail:sales@weiking.com http://www.weiking.com
V1.0 2015.11.9
DC/DC CONVERTERS WK302824/28S-150
28V NOMINAL INPUT 150WATTS

The converter will be permanently damaged if the positive remote sense is shorted to ground. Damage may
also result if the output common or positive output is disconnected from the load with the remote sense leads
connected to the load.

Synchronization (Sync)
A synchronization feature is include with the WK302824/28S-150 series that allows the user to match the
switching frequency of the converter to the frequency of the system clock.
WK302824/28S-150 converters are switching regulators with a constant switching frequency of 520kHz. The
external synchronization feature allows the user to adjust the nominal frequency within the range of 600kHz to
800MHz at a level from 4.5V to 5.5V. The synchronization pulse width should be between 15ns and 150ns.
The sync pin should be unconnected when not in use.

Heat Sink Selection


The absolute maximum allowable case temperature is 105C, to select a heat sink for WK302824/28S-150
Series, the following formula for convective heat flow must be used:
1.43
T
A 6.45 0.85
80 P

Where

A= aera of heat sink,cm2


T= difference between case temperature and ambient temperature, C
P= power dissipation,W.

NOTES
1) Please properly connect pins of power module to PCB following instructions of parts specification.
2) To prevent pins of power module from being stressed to cause glass insulators cracked and power module leaked, please install
power module with fixed flanges or screws prior to soldering pins of power module.
3) The bottom of power module should be tightly fitting to heat sink. If necessary, thermal washers and shockproof gaskets can be
employed.
4) In any case, bending of pins should be avoided to keep glass insulators from cracking and loss of hermeticity.

Weiking Electronics Manufacturing (Xian) Co.,Ltd


Tel: +86-65660060-652 Fax: +86-65660061 E-mail:sales@weiking.com http://www.weiking.com
V1.0 2015.11.9
DC/DC CONVERTERS WK302824/28S-150
28V NOMINAL INPUT 150WATTS

ENVIRONMENTAL SCREENING

TEST/INSPECTION REQUIREMENTS
NO. METHODS CONDITIONS
ITEMS CLASS M CLASS E CLASS I
MIL-STD-883 METHOD
1 INTERNAL INSPECTION - 100% 100% 100%
2017
HIGH TEMPERATURE
2 MIL-STD-810.3 125C,48h 100% - -
STORAGE

MIL-STD-883 METHOD
3 TEMP-CYCLE CONDITION B 100% 100% -
1010

CONSTANT MIL-STD-202 METHOD


4 Y1, 3000g, 1min 100% 100% -
ACCELERATION 212
INTERMEDIATE DETAILED PRODUCT AMBIENT
5 100% 100% -
ELECTRICAL TEST SPECIFICATION TEMPERATURE
MAX OPERATING TEMP,
100% - -
160h
BURN-IN DETAILED PRODUCT MAX OPERATING TEMP,
6 - 100% -
SPECIFICATION 96h
MAX OPERATING TEMP,
- - 100%
48h
AMBIENT
100% 100% 100%
FINAL ELECTRICAL TEMPERATURE
DETAILED PRODUCT
7 TEST
SPECIFICATION MIN OPERATING TEMP 100% 100% 100%
MAX OPERATING TEMP 100% 100% 100%
MIL-STD-883 METHOD
CONDITION A1 100% 100% -
1014
8 SEAL
MIL-STD-883 METHOD
CONDITION C1 100% 100% 100%
1014
EXTERNAL MIL-STD-883
9 - 100% 100% 100%
INSPECTION METHOD 2009

Weiking Electronics Manufacturing (Xian) Co.,Ltd


Tel: +86-65660060-652 Fax: +86-65660061 E-mail:sales@weiking.com http://www.weiking.com
V1.0 2015.11.9
DC/DC CONVERTERS WK302824/28S-150
28V NOMINAL INPUT 150WATTS

MECHANICAL SPECIFICATIONS

Weight: 150g Case Material10# Steel

e.g. WK302824S-150M:

PIN PIN FUNCTION


1 +Vin POSITIVE INPUT
2 GNDi INPUT COMMON
3 NC NO CONNECTION
4 INH INHIBIT
5 SYNC SYNC
6 +Vo POSITIVE OUTPUT
7 NC NO CONNECTION
8 GNDo OUTPUT COMMON
9 -S SENSE RETURN
10 +S POSITIVE SENSE

ORDERING GUIDE

WK 30 28 24 S - 150 M

Grade: M=Military; E=High reliability; I=Standard


Output power: 150=150W
Number of output: S=Single
Output voltage: 24=24V; 28=28V
Nominal Input voltage: 28=28V
Serials number
Company ID

MARKING SPECIFICATION
Production Number: 1126 004, for example, indicates this product has been manufactured in the 26th week of
2011, and the serial number is 004.

Weiking Electronics Manufacturing (Xian) Co.,Ltd


Tel: +86-65660060-652 Fax: +86-65660061 E-mail:sales@weiking.com http://www.weiking.com