Professional Documents
Culture Documents
FEATURES
50V/50ms Transient Voltage MODELS
18VDC ~ 36VDC Permit Input OUTPUT VOLTAGE (VDC)
150W Output Power
Sync Function, Inhibit Function SINGLE
Over Current/Short Circuit Protection 24
Optocoupler Feedback 28
Remote Sense on Single Output Models
DESCRIPTION
The WK302824/28S-150 Model of high-frequency applications. Units are available with standard
DC/DC converters offers ruggedness, reliability and screening, and fully compliant with class E/M
features required to meet the design challenges of screening.
high reliability market. WK302824/28S-150Model The input filter circuit is designed to reduce
utilizes hybrid integration technology and all-metal electro-magnetic interference. The typical input
hermetic enclosure. This Model provides up to 150 voltage is 28V, and ranges from 18V to 36V. The
watts output power over the full temperature range modules can withstand 50V/50ms input surge
of -55 to +105C with up to 85% efficiency. voltage. The WK302824/28S-150 Model also
The WK302824/28S-150 Model small size, low provides some functions such as synchronization
height, and hermetically sealed metal enclosures (Sync), inhibit and over current /short circuit
make them ideal for use in military, protection.
aerospace/aviation and with other high reliability
ELECTRICAL CHARACTERISTICS
WK302824S-150 WK302828S-150
PARAMETERS CONDITIONS1) UNITS
MIN TYP MAX MIN TYP MAX
OUTPUT VOLTAGE VIN=18VDC ~ 36VDC 23.52 24.00 24.48 27.44 28.00 28.56 V
OUTPUT CURRENT VIN=28VDC 0 - 6.25 0 - 5.35 A
VIN=28VDC 20MHz
OUTPUT - 30 80 - 50 100 mVp-p
FULL LOAD
RIPPLE VOLTAGE2)
MIN TO MAX TC - - 150 - - 200 mVp-p
VIN=18VDC ~ 36VDC - 40 80 - 40 80
LINE REGULATION mV
MIN TO MAX TC - - 120 - - 120
VIN=28VDC
NO LOAD TO FULL - 100 200 - 100 200
LOAD REGULATION LOAD mV
MIN TO MAX TC - - 300 - - 300
CONTINUOUS 18 28 36 18 28 36
INPUT VOLTAGE V
50V/50ms3) - - 50 - - 50
NO LOAD - 30 100 - 50 100 mA
FULL LOAD
INPUT CURRENT - 6.3 - - 6.5 - A
VIN=28VDC
INHIBITED - 5 20 - 5 20 mA
SHORT CIRCUIT
SHORT CIRCUIT TIME - - 10 - - 10 s
PROTECTION
EFFICIENCY VIN=28VDC 81 85 - 79 83 - %
NOTES
1) Unless otherwise specified, Tc=25C, Vin=28 VDC , 100% load.
2) Using tip and barrel measurement.
3) Guaranteed by design.
4) Recovery time is measured from application of the transient to point at which VOUT is within 1% of VOUT at final value, transition time >
25s.
WK302824S-150:
APPLICATION NOTES
Inhibit Function
The INH pin can be used as an external shut down for applications requiring on/off operation.
A logic pulled low (0 to 0.3V) on INH pin disables the converter.
No connection on INH pin enables the converter.
The converter will be permanently damaged if the positive remote sense is shorted to ground. Damage may
also result if the output common or positive output is disconnected from the load with the remote sense leads
connected to the load.
Synchronization (Sync)
A synchronization feature is include with the WK302824/28S-150 series that allows the user to match the
switching frequency of the converter to the frequency of the system clock.
WK302824/28S-150 converters are switching regulators with a constant switching frequency of 520kHz. The
external synchronization feature allows the user to adjust the nominal frequency within the range of 600kHz to
800MHz at a level from 4.5V to 5.5V. The synchronization pulse width should be between 15ns and 150ns.
The sync pin should be unconnected when not in use.
Where
NOTES
1) Please properly connect pins of power module to PCB following instructions of parts specification.
2) To prevent pins of power module from being stressed to cause glass insulators cracked and power module leaked, please install
power module with fixed flanges or screws prior to soldering pins of power module.
3) The bottom of power module should be tightly fitting to heat sink. If necessary, thermal washers and shockproof gaskets can be
employed.
4) In any case, bending of pins should be avoided to keep glass insulators from cracking and loss of hermeticity.
ENVIRONMENTAL SCREENING
TEST/INSPECTION REQUIREMENTS
NO. METHODS CONDITIONS
ITEMS CLASS M CLASS E CLASS I
MIL-STD-883 METHOD
1 INTERNAL INSPECTION - 100% 100% 100%
2017
HIGH TEMPERATURE
2 MIL-STD-810.3 125C,48h 100% - -
STORAGE
MIL-STD-883 METHOD
3 TEMP-CYCLE CONDITION B 100% 100% -
1010
MECHANICAL SPECIFICATIONS
e.g. WK302824S-150M:
ORDERING GUIDE
WK 30 28 24 S - 150 M
MARKING SPECIFICATION
Production Number: 1126 004, for example, indicates this product has been manufactured in the 26th week of
2011, and the serial number is 004.