Professional Documents
Culture Documents
Where,
F= axial force in each lacing bar
(7) Check for compressive strength
Solution :
For steel fe 410 fy = 250 N/mm2
For m 25 concrete, fck = 25 N/mm2
FOR ISHB 350 COLUMN
h= 350 mm
Bf =250 mm
Tf = 11.6mm
Tw= 8.3 mm
provide 50 mm equal projection all around the column
width of plate
Bp = 350 + 50 + 50 = 450 mm
Dp = 250 + 50 +50 = 350 mm
Use base plate of size 450 mm* 350 mm
Gross area of base plate provided = 450 * 350 = 157500 mm2
if the ends of column are not milled/machined, the splice and connections
are designed to resist the total axial load and tension, if any.
10. The web splice plates are designed to resist maximum shear force.
11. If packing are provided between the splice plate and column flange
and more than 6mm in thickness, the design shear capacity of the
bolts is reduced as per cl. 10.3.3.3 of IS : 800-2007.
A column section ISHB 250@ 500.3 N/m is carrying a factored load of
600 kN. Design a suitable column splice. Use 16 4.6 grade bolts and
steel of grade Fe 410.
Solution..
For 4.6 grade bolts,
Fub =400 N/mm2
For fe 410 plate fu = 410 N/mm2
fy = 250 N/mm2
For column ISHB 250 @ 50.3 N/m
bf = 250 mm
tf = 9.7 mm
Provide pitch = 50 mm
Edge distance = 1.5 d0 =1.5 *18 =27 mm provide 30 mm
Depth of splice plate
=(4 * 50) +(4*30)
=320 mm
Provide splice plate 320*250*6mm 0n column flanges.