INTRODUCTION The Class 9036 Type DG float switch opens and closes an electric circuit by
an upward ar downward movement of the lever arm, controlling the liquid in
a receiving tank or sump.
The contacts of a standard action float switch e/ose on liquid rise. The
contacts of a reverse action float switch open on liquid rise. The reverse
action kit may be installed al the factory (Form R) or in the field (9049 A58).

SPECIFICA TIONS Table 1: Maximum Tolerances

Max. Force To Trip Max. Weight Supported


Type Std. Switch Forme
Up Down
{no compensating spring) {w/ compensating spring)
DG-2 9 oz (255 g) 8 oz (227 g) 6 oz (170 g) 60 oz (1701 g)
DG-2 Form R 8 oz (227 g) 8 oz (22_7 9) 4 oz (113 g) 60 oz (1701 9)

Table 2: Electrlcal Ratings

Horsepower Control Circult


Voltage
Single Phase AC Polyphase AC DC Ratlng
115VAC 2 llp 3 hp 1/2hp

-
230VAC 3 hp 5 hp 1/2hp
4601575VAC 1 hp - A600

32VDC - - 114 hp

Enclosure Rating: NEMA 1


Temperatura Rating: -40 to +185 F (-40 to +86 C)

INSTALLATION & WIRING Mount the float switch horizontally, using the mounting feet (if provided). Wire
the float switch fer your application (see Figure 1 ).

<
A DANGER Motor Controller LI
UNE
L2 L1
LINE
L2 Control Clrcult
N
U)

HAZARDOUS VOLTAGE Appllcatlon l l 1 Switch Applicatlon


:i:
Disconnect all power befo re wiring or
servicing float switch.
o
11)
U)
LINE LOAD LOAD LINE
lnstall and secura the cover befare L1 T1 T2 L2
restoring power.
Electric shock wlll resuit In death or
serlous lnjury.

Figure 1: Wlrlng Dlagrams

!DI
C 1998 Square D Ali Rlghls Reservad
SQUARE D
Class 9036 Type DG Float Switch Bulletin No. 65013-008-62A
lnstructlon Bulletin May 1998

Motor Protection This float switch does not provide motor protection, but it may be used as a
pilo! to operate an overload-protected starter. Contact your local Square D
sales office fer information on our complete line ol motor starters.

COMPENSATING SPRING A compensating spring may be installed at the lactory (Form C) or ir the lield
(9049 A 19). lf the weight of the red and stops plus the force up to trip exceeds
the buoyancy of the float, a compensating spring and a center hole float are
required. Fer more information, refer to lnstruction Bulletin L-4167A.

A CAUTION
UNINTENDED EQUIPMENT OPERATION
Do not use compensating springs on reverse action float switches.
Float switches are factory calibrated. Do not adjust unless you are:
- lnstalling a compensating spring, or
- Changing the number of stops or tubing length.
Fallure to lollow these lnstructions can result In injury or equlpment damage.

REPLACEMENT PARTS & Table 3: Replacement Parts


ACCESSORIES ltem Descrlplion Qly. Part No.
1 Set ol movable and stationary contacts 1 9998 PC-242
2 Replacement cover (specily completeClass & Type) 1 6 507970152
3 Compensalng spring kit (to add Form C in lhe field) 1 9049 A19
4 Floal lever arm 1 1548-X2
- Reverse acllon float lever arm (to add Form A in the lield) 1 9049A58
Give completa nameplate data (Class, Type, Form} when orderin9 replacement parts.

Table 4: Float Klts

Float Type Material Tubing Slops Part No. Qty. Used On


Brass 9049 A6 1
304 stainless steel 9036 DG-2.
Tapped at top Aluminum 2 9049 A6A 1
9036 DG-2 R
316 stainless stecl Stainless steel 9049A6 S 1
Brass 9049A6C 1
304 stainless steel 9036 OG-2C,
Centcr hole Alumlnum 4 9049A6CA 1
90360G-2CR
316 stainless steel Stainless steel 9049A6CS 1
Floats are 7 inches long and come wilh 5 feet of tubing.

Table 5: Tubing Kits

Figure 2: Replacement Parts Material Qty. Part No. Used On


Brass As needed 9049 T1 All 9036
Aluminum As needed 9049 T1A All 9036
Stainless s'.eel As needed 9049 T1S All 9036
Kits contain 2-1/2 feet of tubing plus a connector.

Square O Company Square D and are registered trademarks of Square D Company.


8001 Hwy 64 East
Knightdale, NC 27545 Electricat equipnenl should be serviced only by qualilied electrical maintenance personnel. No
(919) 266-3671 responslbillly Is assumed by Square D for any consequences arislng out of the use ol thls malerlal.

IDI
2 C 1998 Square D Ali Righls Reserved
SQUARE D
ESQUEMA DE MONTAJE DE INTERRUPTOR DE NIVEL
SQUARE-"D" (USA)

CONTROL SQUARE-D

l
MOD. DG-2 GG-2 AG-5

TOP5

SOPORTE
---.A PARA DARLE UNA
--- E.SP'ECIE DE ALERO PARA QUE LA
----- BOYA NO TOQUE LA PARED

GUIA
---- SE COLOCA PARA QUELA.
VARILJ.A NO SE INCLINE Y SE
DESUZE VERT!CAlMENTE
PUEDE VARIAR (LA POS!C!ON ES
EFERENCIAL)

O COBRE

NOTA: * NO INCLUm GUIA y SOPORrn


"El, MODELO DG-2 !'ARA TANQlfl' E/,EVADO !NSTAlAR !NVER11!)0 (DF: CABEZA)