You are on page 1of 53

UNIVERSIDAD

NACIONAL DE LOJA

REA DE LA ENERGA, LAS INDUSTRIAS Y LOS RECURSOS


NATURALES NO RENOVABLES

CARRERA INGENIERA ELECTRNICA Y TELECOMUNICACIONES

MEMORIA TCNICA

PROYECTO CABLEADO ESTRUCTURADO


DISEO DE LA RED DE CABLEADO
ESTRUCTURADO PARA EL EDIFICIO DEL IESS
UBIDCADO EN LA CUIDAD DE SANGOLQU, EN EL
CANTN RUMIAHUI DE LA PROVINCIA DE
PICHINCHA

INTEGRANTES:
Mara Camila Arrobo Fernndez
Nelson Eduardo Barrazueta Valle
Carlos Eduardo Flores Gaona
DOCENTE:
Ing. Andy Vega

MDULO:
Sptimo B
TABLA DE CONTENIDO
1.ANTECEDENTES ..................................................................................................................................... 4
1.1. UBICACIN .................................................................................................................................... 4
1.2. ESTRUCTURA ................................................................................................................................. 4
1.2.1. PLANTA BAJA .......................................................................................................................... 4
1.2.2. PRIMERA PLANTA ................................................................................................................... 4
1.2.3. SEGUNDA PLANTA .................................................................................................................. 4
1.2.4. TERCERA PLANTA ................................................................................................................... 4
2. ALCANCE DEL PROYECTO ..................................................................................................................... 5
3. CARACTERIZACIN FSICA DEL INMUEBLE ........................................................................................... 5
4. SISTEMA DE VOZ Y DATOS.................................................................................................................... 6
4.1. INTRODUCCIN A LAS NORMAS DE LOS SISTEMAS DE CABLEADO ESTRUCTURADO................... 6
4.1.1. TIA/EIA-568-B ......................................................................................................................... 7
4.1.2. TIA/EIA-569 ............................................................................................................................ 8
4.1.3. TIA/EIA-606-A ......................................................................................................................... 9
4.1.4. TIA/EIA-TSB-67 ....................................................................................................................... 9
4.2. JUSTIFICACIN DE LA SOLUCIN ADOPTADA ............................................................................. 10
4.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 15
4.4. DISTRIBUCIN ............................................................................................................................. 18
4.4.1. TOMAS DE DATOS ................................................................................................................ 18
4.4.2. TOMAS DE VOZ..................................................................................................................... 24
4.4.3. TOTAL DE TOMAS DE VOZ Y DATOS ..................................................................................... 30
5. SISTEMA DE ALARMA CONTRA INCENDIOS ....................................................................................... 30
5.1. INTRODUCCIN ........................................................................................................................... 30
5.2. DESARROLLO ............................................................................................................................... 30
5.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 31
5.4. DISTRIBUCCIN ........................................................................................................................... 33
5.4.1. SENSORES DE HUMO Y TEMPERATURA ............................................................................... 33
5.4.2. ESTACIONES MAUALES ......................................................................................................... 36
5.4.3. LUCES ESTROBOSCPICAS ................................................................................................... 38
5.4.4. TOTAL DE EQUIPOS USADOS ................................................................................................ 39
6. SISTEMA DE ALARMA CONTRA ROBO ................................................................................................ 39

2
6.1. INTRODUCCIN ........................................................................................................................... 39
6.2. DESARROLLO ............................................................................................................................... 40
6.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 42
6.4. DISTRIBUCIN ............................................................................................................................. 45
7. SISTEMA DE CCTV ............................................................................................................................... 47
7.1. INTRODUCCIN ........................................................................................................................... 47
7.2. DESARROLLO ............................................................................................................................... 48
7.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 50
7.4. DISTRIBUCIN ............................................................................................................................. 52

3
1. ANTECEDENTES
1.1. UBICACIN
El presente proyecto detalla el diseo de cableado estructurado para el edificio del IESS ubicado en la
ciudad de Sangolqu (Venezuela y Montfar), cantn Rumiahui, provincia de Pichincha.

Figura1. Ubicacin del Edificio

1.2. ESTRUCTURA
La edificacin consta de cuatro pisos distribuidos de la siguiente manera:

1.2.1. PLANTA BAJA


Es la parte principal de acceso al edificio. Est conformada por una sala 2D, sala 3D, sala de crisis,
comedor de personal, recepcin, auditorio, cuarto de copiado y guardiana, entre los espacios fsicos a
tener en cuenta para el diseo de la red.

1.2.2. PRIMERA PLANTA


Se accede por medio de escaleras o ascensor interno. Consta de oficina 1, oficina 2, oficina 3, oficina
4, oficina 5, secretara y sala de reuniones.

1.2.3. SEGUNDA PLANTA


Su acceso principal es por escaleras o ascensor interno. Tiene en su estructura fsica cinco oficinas:
oficina 1, oficina 2, oficina 3, oficina 4, oficina 5; tambin consta de una secretara y sala de reuniones.

1.2.4. TERCERA PLANTA


Se accede por escaleras o ascensor interno. Es la ltima planta del edificio. Consta de cinco oficinas:
oficina 1, oficina 2, oficina 3, oficina 4, oficina 5; tambin consta de una secretara y sala de reuniones.

Este diseo se lleva a cabo teniendo en cuenta las necesidades de los usuarios en este tipo de centros,
dotndolo de las tecnologas ms adecuadas teniendo en cuenta siempre en dejar la infraestructura en
previsin necesaria para que dicho centro pueda actualizarse conforme a las necesidades presentes y
futuras.

4
2. ALCANCE DEL PROYECTO
El alcance de este documento comprende:

El diseo de cableado estructurado para el inmueble de referencia como soporte fsico de la


red de rea local.
Dicho diseo incluye las prescripciones tcnicas de los materiales utilizados, los procedimientos
de ejecucin del material segn la normativa, con el objeto de calcular los presupuestos de
adquisicin e instalacin de materiales y equipos electrnicos asegurando garantas de calidad
derivadas de la aplicacin de la normativa vigente.

Dentro del proyecto se especifican las definiciones que corresponden a:

Cables de datos
Elementos de interconexin
Equipos electrnicos a implementar.

El proyecto contempla la electrnica de red que permita implementar la topologa prevista en esta red
de rea local, de manera acorde con los estndares y normativas que son de aplicacin.

3. CARACTERIZACIN FSICA DEL INMUEBLE


El inmueble que se ocupa consta de cuatro plantas o niveles (descrito anteriormente). En la planta baja
no existe espacio especfico destinado para telecomunicaciones por lo que se proceder a adecuar uno
exclusivamente para este fin. En las plantas superiores se cuenta con un espacio especfico para
telecomunicaciones lo cual nos presenta una enorme ventaja para el posterior diseo de la red. La
comunicacin entre plantas se realiza mediante el ducto de instalaciones presente en el diseo del
inmueble.

Las reas a cubrir por el cableado estructurado se detallan en la siguiente tabla:

NIVEL DEPENDENCIA REA


Sala 3D 72,00 m
Recepcin 3,62 m
Sala 2D 110,53 m
PLANTA
Sala de Crisis 74,44 m
BAJA
Comedor de Personal 69,25 m
Copiado 5,46 m
Auditorio 137,80 m
Oficina 1 130,08 m
Oficina 2 29,92 m
Oficina 3 20,98 m
PRIMERA
Oficina 4 27,12 m
PLANTA
Oficina 5 97,15 m
Sala de Reuniones 12,88 m
Secretaria 32,21 m

5
Oficina 1 130,08 m
Oficina 2 29,92 m
Oficina 3 20,98 m
SEGUNDA
Oficina 4 27,12 m
PLANTA
Oficina 5 97,15 m
Sala de Reuniones 12,88 m
Secretaria 32,21 m
Oficina 1 130,08 m
Oficina 2 29,92 m
Oficina 3 20,98 m
TERCERA
Oficina 4 27,12 m
PLANTA
Oficina 5 97,15 m
Sala de Reuniones 12,88 m
Secretaria 32,21 m
Tabla 1: reas de lo espacios del edificio.

4. SISTEMA DE VOZ Y DATOS


4.1. INTRODUCCIN A LAS NORMAS DE LOS SISTEMAS DE CABLEADO ESTRUCTURADO
La tendencia del medio en cuanto al mayor aprovechamiento de recursos con la menor inversin
posible obliga a buscar estructuras y sistemas en todas las ramas de servicio que se necesita instalar en
un edificio para el uso cotidiano con proyeccin hacia varios aos en el futuro.

Un sistema de cableado estructurado es fsicamente una red de cable nica y completa, con
combinaciones de alambre de cobre (UTP), cables de fibra ptica, bloques de conexin, cables
terminados en diferentes tipos de conectores y adaptadores.

El concepto de cableado estructurado hace referencia al soporte fsico de un sistema de


comunicaciones o telemtico cuya infraestructura de cableado permite:

Disponer de tomas de acceso terminal estandarizadas tanto para voz como para datos o bien
para cualquier otra necesidad telemtica.
Distribuye dichas tomas en los diferentes departamentos de acuerdo a las necesidades y
mantiene cierto nmero de lugares de posible uso futuro.
La distribucin de esta red se lleva a cabo ya sea en una planta, en un edificio o bien en un
campus o conjunto de edificios.
La gestin de administracin de la red se realiza desde unos puntos en los cuales se instalan
distribuidores, repartidores o concentradores en los cuales confluyen las diferentes lneas de
cable o fibra ptica.

Con todo lo expuesto, se pretende que el sistema a ejecutar aporte simplificacin en la gestin de
redes, flexibilidad y facilidad para poder llevar a cabo cambios de configuracin y tecnologa. De igual
manera permite la integracin en esta red de mltiples servicios de telemtica bajo el mismo soporte
simplificando los procedimientos y obteniendo altos niveles de calidad y eficacia. Otro punto

6
importante es destacar la vida til del sistema de cableado estructurado ya que es muy superior a otros
sistemas que se emplean para la prestacin de servicios.

Por lo tanto y teniendo en cuenta todas estas caractersticas es necesaria una cuidadosa planificacin
y ejecucin para asegurar que la inversin realizada garantice que la misma es capaz de dar soporte a
las necesidades presentes y permita la flexibilidad suficiente para otras en el futuro. Finalmente una de
las herramientas fundamentales es que todo el proyecto se realice conforme a los estndares o normas
especficos para cableado estructurado.

El sistema de cableado estructurado utilizado para las telecomunicaciones, es el producto de las


constantes investigaciones y posterior normalizaciones a las que debe estar sujeto. Todos los beneficios
que se obtienen como flexibilidad, soporte a diversos ambientes de tecnologa, bajos costos de
mantenimiento, entre otros, estn sujetos a normas y estndares internacionales que son regulados
por la ANSI/TIA/EIA.

Los estndares de telecomunicaciones implementados por estas organizaciones son:

TIA/EIA- 568-B (Cableado)


TIA/EIA-569 (Ductos y Canalizaciones)
TIA/EIA-606-A (Administracin)
TIA/EIA-TSB-67 (Test de Performance)

Estas son las normativas a las que se rige el presente proyecto de diseo para lograr todas las
caractersticas descritas hasta ahora en este documento.

4.1.1. TIA/EIA-568-B
La norma TIA/EIA 568B dicta las regulaciones para Cableado Estndar de Telecomunicaciones para
edificios comerciales

El propsito del estndar de Cableado es:

Dar la direccin para equipos y diseo de productos de cableado


Especifica un diseo de cableado genrico
Respalda un ambiente de mltiples productos y fabricantes
Independiente de las aplicaciones.
Establece los requisitos mnimos de desempeo
Tecnologa abierta
Indicar la planificacin e instalacin de un sistema de cableado estructurado.

El alcance de la norma tiene como objetivo:

Especificar requisitos de los componentes, configuraciones de los conectores y medidas


reconocidas.
Topologa de conexin
Distancias del cableado

7
Interfaces de usuario
Prcticas de instalacin
Rendimiento de la lnea.

Los elementos que forman de cableado estructurado son:

Cableado Horizontal
Cableado Vertical (Backbone del Edificio y del Campus)
rea de Trabajo (WA)
Closet de telecomunicaciones (TC)
Cuarto de Equipos
Entradas de Servicio (EF)

Para el diseo del proyecto partimos de la normativa de cableado horizontal que detalla la distancia
mxima que debe existir entre el WA hasta el cuarto de telecomunicaciones TC que es de 90m con un
adicional de 10m para la distancia combinada de cables de empate utilizados para conectar el WA y el
TC. De la misma forma la topologa de conexin se la realiza en estrella. El cable a emplear es UTP
Categora 6a. Los dems elementos para el sistema de cableado estructurado se detallan ms adelante.

4.1.2. TIA/EIA-569
La norma TIA/EIA-569 detalla las regulaciones para Espacios y Rutas de Telecomunicaciones estndar
para Edificios Comerciales. Da el conocimiento de las rutas y espacios que deben soportar para una
gran variedad de servicios de telecomunicaciones adems de voz y datos. Son especificaciones para
soportar multi-productos y multi-fabricantes.

El propsito del estndar es:

Especificar normas para el diseo y construcciones de la infraestructura que da soporte a los


medios de transmisin y al equipo de telecomunicaciones como son los espacios de (cuartos
de telecomunicaciones y rutas para edificios comerciales.

El alcance de la norma es:

Se limita a los aspectos de telecomunicaciones en el diseo y construccin de edificios


comerciales
El estndar no cubre los aspectos de seguridad en el diseo del edificio
Cubrir las rutas y reas que son usados para los terminados de las medias de transmisin e
instalacin de los equipos de telecomunicaciones
Influencias de otros servicios del edificio como elctricos

Los elementos que forman parte de la regulacin de esta norma son:

Ruta de cableado horizontal


Ruta de cableado vertical.
rea de trabajo
Closet de telecomunicaciones.

8
Cuarto de Equipos
Entrada de servicios.

En el presente diseo de acuerdo a la norma la ruta escogida para el paso de la escalerilla principal se
la realiza por cielo falso respetando las distancias mnimas respecto del tendido elctrico, as como las
medidas de la escalerilla para el soporte y ubicacin del cable. As mismo para el diseo de las rutas
verticales, el cuarto y closet de telecomunicaciones ubicados estratgicamente para dar cumplimiento
a la norma.

4.1.3. TIA/EIA-606-A
Es le estndar de Administracin para la infraestructura de Telecomunicaciones en Edificios
comerciales. El sistema de administracin puede ser de forma manual (papel), hojas de clculo o
software dedicado para esta funcin.

El alcance de esta norma es:

Asignar identificadores a los componentes de la infraestructura


Especificar reportes presentando la informacin en grupos de registro
Especifica requerimientos grficos y smbolos.

Los elementos a ser Administrados:

Cableado y rutas horizontales


Cableado y rutas verticales
Puestas a tierra
Espacios.
Retenedores de Fuego.

En esta norma se determinan cuatro clases a ser administradas, el diseo de la edificacin en estudio
se encuentra determinado en la clase dos, sin embargo, debido a que la administracin es opcional se
decide no llevar a cabo todas aplicaciones de registros que implican esta norma, no obstante cada
elemento del sistema de cableado se encuentra debidamente identificado y etiquetado para un
perfecto cumplimiento de la regulacin si se evala bajo los criterios descritos anteriormente.

4.1.4. TIA/EIA-TSB-67
Es el estndar de Especificaciones de las pruebas de campo de los Sistemas de Cableado Estructurado.
Define las especificaciones para las pruebas que se deben realizar despus de la instalacin. Verifica el
funcionamiento del enlace.

El alcance de esta norma es:

Especificar los requisitos de funcionamiento para enlaces instalados.


Define mtodos de prueba
Interpretacin de los datos
Comparacin contra procedimientos de laboratorio.

9
Con esta norma se puede determinar la calidad del enlace. Como es una norma que se aplica una vez
instalados los elementos del sistema de cableado solo hasta entonces se podr verificar la misma. Los
parmetros de atenuacin, diafona, longitud y mapeo determinarn la eficiencia del sistema instalado.

A travs de un sistema de cableado estructurado correctamente diseado y ejecutado es posible


suministrar diversos servicios de telecomunicaciones, proporcionando al usuario final la solucin
tcnica adaptada a sus necesidades integrando aplicaciones, independientemente de toda la
infraestructura necesaria y atendiendo las normativas vigentes en cada caso.

4.2. JUSTIFICACIN DE LA SOLUCIN ADOPTADA


Teniendo en cuenta que la red de Cableado Estructurado se la implementa en un centro pblico y en
el mismo se pretende dar solucin a las problemticas que expongan los usuarios, demandar medios
tecnolgicos eficaces con sistemas de respuesta ptima. Es recomendable que los subsistemas que
componen la red se basen en cableado de pares balanceados.

Los tendidos realizados con cable UTP Categora 6a de 4 pares sern los necesarios para satisfacer los
requisitos y la electrnica deber cumplir en todo momento la posibilidad de disponer en la base
terminal de cada punto una conexin de 1 Gb.

El inmueble no requiere la implementacin de un Centro de Proceso de Datos, lo que significa que esta
funcin puede ser desempeada perfectamente por el Cuarto de Telecomunicaciones localizado en la
primera planta.

La localizacin de este punto y desde el cual se distribuye en topologa estrella hacia todas las bases de
acceso terminal de los diferentes servicios, permite tener distancias controladas cuyas longitudes, para
el caso del cableado horizontal nunca sobrepasan los 90 metros que impone la norma.

La solucin del sistema de distribucin en topologa estrella para la red telemtica ser la adoptada
con las restantes instalaciones, ya sea televisin, seguridad e incendios.

El rea de puesto de trabajo deber incluir todos los elementos necesarios para la conexin de un
equipo terminal a la red de cableado estructurado. La conexin de las mismas se realizar en las tomas
de telecomunicacin dispuestas en las diferentes reas de trabajo mediante latiguillos de conexin tipo
UTP categora 6a.

El nmero de tomas de voz y datos de cada zona de trabajo depende de la naturaleza uso o clasificacin
del mismo. En los anexos 1 se detalla el listado de los mismos. Las tomas terminan en conectores tipo
hembra Rj45 categora 6a tipo UTP insertado en un face place panduit de 1 o 2 posiciones dependiendo
del caso. Las tomas de telecomunicacin irn alojadas en cajas rectangulares profundas empotradas
en paredes o suelo segn sea el caso. De ser necesario y no teniendo otra solucin se puede poner
tomas sobrepuestas.

Se emplean cajas de paso para tomar las bajantes desde la escalerilla principal hacia la toma de
telecomunicaciones, se conectan a la red general mediante tubo conduit de salvo en casos
puntuales donde se utiliza tubera conduit 1.

10
La conexin entre el equipo del usuario y la roseta se lo realiza mediante patch cords panduit categora
6a 3FT (0.91m) en el cuarto de telecomunicaciones con patch cords panduit categora 6a 7FT (2.13m)
cumpliendo con la distancia mxima establecida en la norma.

En el caso que nos ocupa al cableado horizontal tiene su origen en el panel de parcheo del armario de
distribucin principal localizado en la primera planta, se realiza la interconexin con el distribuidor
secundario para finalizar en la roseta que forma el puesto de trabajo. La escalerilla de distribucin
principal est localizada en el teco falso del edificio en cada una de las plantas. Se ha respetado la
distancia frente a otros servicios principalmente los de baja tensin, lo que garantiza inmunidad frente
a cualquier tipo de interferencia inducida. El dimensionamiento de la escalerilla garantiza siempre
radios de curvatura superiores a 5cm en los puntos de cruce de la red.

La topologa de distribucin de cableado vertical ser en estrella para garantizar condiciones de


rendimiento ptimos. Cada uno de los distribuidores secundarios se interconecta con el distribuidor
principal instalado en la primera planta del edificio. La conexin se la realizar con cable UTP categora
6a debido a que las distancias del cableado vertical se encuentran dentro de la norma establecida.

Figura 2. Cableado Vertical del Edificio

El switch de distribucin principal es un HP 1920-8G-Poe Capa 2 administrable. Que es un conmutador


gigabit PoE + 8 puertos con gestin inteligente y avanzada con un rendimiento de alimentacin PoE de
180W y dos puertos SFP GbE. Es un dispositivo electrnico que tiene prestaciones muy altas de calidad
a un costo relativamente bajo con el cul se pueden cubrir los requerimientos del sistema. La condicin

11
de administrable nos permite determinar la jerarqua de los elementos a conectar, as como la
velocidad de conexin y la proteccin de la red contra intrusos.

Los switches de distribucin de planta se recomiendan marca HPE 1950 48G, con tecnologa PoE Capa
2. Tiene 48 puertos 48x10/100 + 2xGigabit SFP combinado. Las prestaciones de servicio para la red son
de alta calidad y el costo es promedio.

Se designan switches secundarios administrables para poder realizar el cableado vertical. La capacidad
administrable nos permite adems de dar seguridad a la red jerarquizar un switch de planta para poder
realizar las interconexiones entre plantas.

Los Racks que se utilizan para la instalacin de los dispositivos electrnicos son de marca BEAUCOUP
gabinete abatible Neptuno, cdigo I-60529 de 25u que soportan carga mxima de 300 kg. La disposicin
de los dispositivos en el rack ser de la siguiente manera:

Armario Planta Baja

Altura en U Armario RACK 25U COMPOSICIN


1U 25 Reserva
SWA-01PB Datos
1U 24

1U 23 OR-01PB
1U 22 PP-01PB Datos
1U 21 Reserva
1U 20 SWA-02PB Voz
1U 19 OR-02PB
1U 18 PP-02PB Datos
1U 17 Reserva
1U 16 Reserva
1U 15 Reserva
1U 14 Reserva
1U 13 Reserva
1U 12 Reserva
1U 11 Reserva
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva

12
1U 2 Reserva
1U 1 Multitomas
Tabla 2

Armario Principal Primera Planta

Altura en U Armario RACK 25U COMPOSICIN


1U 25 Reserva
1U 24 Switch Principal 8G-Poe
1U 23 Reserva
1U 22 SWA-01PP Datos
1U 21 OR-01PP
1U 20 PP-01PP Datos
1U 19 Reserva
1U 18 SWA-02PP Voz
1U 17 OR-02PP
1U 16 PP-02PP Datos
1U 15 Reserva
1U 14 Reserva
1U 13 Reserva
1U 12 Reserva
1U 11 Reserva
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva
1U 2 Reserva
1U 1 Multitomas
Tabla 3

Armario Segunda Planta

Altura en U Armario RACK 25U COMPOSICIN


1U 25 Reserva
1U 24 SWA-01SP Datos
1U 23 OR-01SP
1U 22 PP-01SP Datos

13
1U 21 Reserva
1U 20 SWA-02SP Voz
1U 19 OR-02SP
1U 18 PP-02SP Datos
1U 17 Reserva
1U 16 Reserva
1U 15 Reserva
1U 14 Reserva
1U 13 Reserva
1U 12 Reserva
1U 11 Reserva
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva
1U 2 Reserva
1U 1 Multitomas
TABLA 4

Armario Tercera Planta

Altura en U Armario RACK 25U COMPOSICIN


1U 25 Reserva
1U 24 SWA-01TP Datos
1U 23 OR-01TP
1U 22 PP-01TP Datos
1U 21 Reserva
1U 20 SWA-02TP Voz
1U 19 OR-02TP
1U 18 PP-02TP Datos
1U 17 Reserva
1U 16 Reserva
1U 15 Reserva
1U 14 Reserva
1U 13 Reserva
1U 12 Reserva
1U 11 Reserva

14
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva
1U 2 Reserva
1U 1 Multitomas
TABLA 5

La configuracin para las terminaciones del cableado horizontal en el WA Jack de 8 posiciones y el TC


Patch Panel en lo referido a las asignaciones PIN/PAR se emplear la 568-B, entre Switches ser en
configuracin cruzada.

Se utilizan UPS de 30 minutos de reserva para la alimentacin de cada armario en cada planta.

4.3. ESPECIFICACIONES TCNICAS


EQUIPOS ELECTRNICOS Y MATERIALES

TIPO EQUIPO DESCRIPCIN MODELO MARCA

Conmutador Gigabit
Switch
PoE + 8 G +180W, HP 1920-8G-PoE
Administrable HP
2SFP GbE. 8 Puertos CAPA 2
Pricipal
RJ45

Conmutador Switch.
PoE+ con 52 puertos
en total: 48 puertos
Switch HPE 1950 48G
PoE+2 SFP Gigabit HP
Secundario 2SFP+2XGT
10/100/100+2
Puertos Rj45
1/10GBASE-T

Gigabit/Ethernet.
Patch Panel Cumple Normas CPP48WBLY PANDUIT
EIA/TIA 568B

Organizador de cables
Organizador
Horizontal 1U, para WMPH1E PANDUIT
de Cables
gabinetes y racks 19"

15
Cable de Parcheo UTP
10Gb 7FT con
Patch Cord
conectores modulares
rea de 20460P7A PANDUIT
TX6A en ambos
Trabajo
extremos Categoria
6a

Cable de Parcheo UTP


10Gb 3FT con
conectores modulares
Patch Cord TC 20460P3A PANDUIT
TX6A en ambos
extremos Categoria
6a

Cable de cobre Cat.


6A UTP TX6A 10 Gig,
riser CMR, 4 pares.
Cable UTP Cat
Conductores 23 AWG 10185PAN6A PANDUIT
6A
con retardante de
llama azul /305m x
rollo

Mdulo universal
Jack RJ45- Categoria 6A, RJ45,
10185PAN6A PANDUIT
Cat6A 10Gb/s 8 posiciones,
8 cables 568A/568B

Gabinete Rack
Gabinete Abatible Neptuno.
I-1026-N BEAUCOUP
Rack Norma INEN 2568 ICE
60529, 19" 25U

16
Multitoma para Rack
de 19" para
Multitomas I-1135 TPL 19-4 BEAUCOUP
alimentacin elctrica
de

Placa Frontal, una


Face Plate salida, acepta dos PANDUIT
20460P2P
Doble mdulos Mini-Com
RJ45

Placa Frontal, una


Face Plate salida, acepta un
20460P1P PANDUIT
Simple mdulo Mini-Com
RJ45

ASEP 2000T UPS


online de 2KVA-
2000VA equivale
UPS a1600W. Respuesta C2KS ASEP
inmediata 4
conectores pantalla
lcd de indicadores

Fabricadas bajo
normativa IEC 60529.
Galvanizada en frio
Cajas de Paso laminado con tapa I-206 BEAUCOUP
metlica
desmontable. Servicio
Pesado

17
Escalerilla para
tendido de redes de
telefona y datos.
Bandeja Tipo I-0772-BNJE
Fabricado en acero BEAUCOUP
Escalerilla 150/100
pregalvanizado.
Desarmable. Soporta
hasta 112Kg/m

Conector Plug 8, 8
wire TX6A modular.
Contactos chapados
Plug RJ45- Plug Conector
con 50 micro PANDUIT
Cat6A RJ45 Cat 6A
pulgadas de oro.
Terminal 24 AWG.
Bolsa 100 unidades

TABLA 6: Materiales y equipos.

4.4. DISTRIBUCIN
4.4.1. TOMAS DE DATOS
PLANTA BAJA TOMAS DE DATOS

Numero Toma Armario Secundario Localizacin

1 TD-PB01 SWA-01PB

2 TD-PB02 SWA-01PB
SALA 3D
3 TD-PB03 SWA-01PB

4 TD-PB04 SWA-01PB

5 TD-PB05 SWA-01PB RECEPCIN

6 TD-PB06 SWA-01PB

7 TD-PB07 SWA-01PB
SALA 2D
8 TD-PB08 SWA-01PB

9 TD-PB09 SWA-01PB

10 TD-PB10 SWA-01PB
SALA DE CRISIS
11 TD-PB11 SWA-01PB

18
12 TD-PB12 SWA-01PB

13 TD-PB13 SWA-01PB

COMEDOR DE
14 AP-PB01 SWA-01PB
PERSONAL

15 AP-PB02 SWA-01PB SALA DE ESPERA

16 TDD-PB01 SWA-01PB
COPIADO
17 TDD-PB02 SWA-01PB

18 TDD-PB03 SWA-01PB

19 TDD-PB04 SWA-01PB

20 TDD-PB05 SWA-01PB AUDITORIO

21 TDD-PB06 SWA-01PB

22 AP-PB03 SWA-01PB

TABLA 7

PRIMERA PLANTA TOMAS DE DATOS

Nmero Toma Armario Secundario Localizacin

1 TD-PP01 SWA-01PP

2 TD-PP02 SWA-01PP

3 TD-PP03 SWA-01PP

4 TD-PP04 SWA-01PP OFICINA 4

5 TD-PP05 SWA-01PP

6 TD-PP06 SWA-01PP

7 TD-PP07 SWA-01PP

8 TD-PP08 SWA-01PP

9 TD-PP09 SWA-01PP SALA DE REUNIONES

10 TD-PP10 SWA-01PP OFICINA 5

19
11 TD-PP11 SWA-01PP

12 TD-PP12 SWA-01PP

13 TD-PP13 SWA-01PP

14 TD-PP14 SWA-01PP

15 TD-PP15 SWA-01PP

16 TD-PP16 SWA-01PP

17 TD-PP17 SWA-01PP

18 TD-PP18 SWA-01PP

19 TD-PP19 SWA-01PP

20 TD-PP20 SWA-01PP

21 TD-PP21 SWA-01PP

22 TD-PP22 SWA-01PP
OFICINA 1
23 TD-PP23 SWA-01PP

24 TD-PP24 SWA-01PP

25 TD-PP25 SWA-01PP

26 TD-PP26 SWA-01PP

27 TD-PP27 SWA-01PP

28 TD-PP28 SWA-01PP

29 AP-PP03 SWA-01PP

30 TD-PP29 SWA-01PP OFICINA 2

31 AP-PP01 SWA-01PP PASILLO

32 AP-PP02 SWA-01PP
SECRETARIA
33 TD-PP30 SWA-01PP

34 TD-PP31 SWA-01PP
OFICINA 3
35 TD-PP32 SWA-01PP

20
36 TD-PP33 SWA-01PP

37 TD-PP34 SWA-01PP

TABLA 8

SEGUNDA PLANTA TOMAS DE DATOS

Nmero Toma Armario Secundario Localizacin

1 TD-SP01 SWA-01SP

2 TD-SP02 SWA-01SP

3 TD-SP03 SWA-01SP

4 TD-SP04 SWA-01SP OFICINA 4

5 TD-SP05 SWA-01SP

6 TD-SP06 SWA-01SP

7 TD-SP07 SWA-01SP

8 TD-SP08 SWA-01SP

9 TD-SP09 SWA-01SP SALA DE REUNIONES

10 TD-SP10 SWA-01SP

11 TD-SP11 SWA-01SP

12 TD-SP12 SWA-01SP

13 TD-SP13 SWA-01SP
OFICINA 5
14 TD-SP14 SWA-01SP

15 TD-SP15 SWA-01SP

16 TD-SP16 SWA-01SP

17 TD-SP17 SWA-01SP

18 TD-SP18 SWA-01SP

19 TD-SP19 SWA-01SP OFICINA 1

20 TD-SP20 SWA-01SP

21
21 TD-SP21 SWA-01SP

22 TD-SP22 SWA-01SP

23 TD-SP23 SWA-01SP

24 TD-SP24 SWA-01SP

25 TD-SP25 SWA-01SP

26 TD-SP26 SWA-01SP

27 TD-SP27 SWA-01SP

28 TD-SP28 SWA-01SP

29 AP-SP03 SWA-01SP

30 TD-SP29 SWA-01SP OFICINA 2

31 AP-SP01 SWA-01SP PASILLO

32 AP-SP02 SWA-01SP
SECRETARIA
33 TD-SP30 SWA-01SP

34 TD-SP31 SWA-01SP

35 TD-SP32 SWA-01SP
OFICINA 3
36 TD-SP33 SWA-01SP

37 TD-SP34 SWA-01SP

38 TD-SP35 SWA-01SP
OFICINA 1
39 TD-SP36 SWA-01SP

TABLA 9

TERCERA PLANTA TOMAS DE DATOS

Nmero Toma Armario Secundario Localizacin

1 TD-TP01 SWA-01TP
OFICINA 4
2 TD-TP02 SWA-01TP

3 TD-TP03 SWA-01TP

22
4 TD-TP04 SWA-01TP

5 TD-TP05 SWA-01TP

6 TD-TP06 SWA-01TP

7 TD-TP07 SWA-01TP

8 TD-TP08 SWA-01TP

9 TD-TP09 SWA-01TP SALA DE REUNIONES

10 TD-TP10 SWA-01TP

11 TD-TP11 SWA-01TP

12 TD-TP12 SWA-01TP

13 TD-TP13 SWA-01TP
OFICINA 5
14 TD-TP14 SWA-01TP

15 TD-TP15 SWA-01TP

16 TD-TP16 SWA-01TP

17 TD-TP17 SWA-01TP

18 TD-TP18 SWA-01TP

19 TD-TP19 SWA-01TP

20 TD-TP20 SWA-01TP

21 TD-TP21 SWA-01TP

22 TD-TP22 SWA-01TP

23 TD-TP23 SWA-01TP OFICINA 1

24 TD-TP24 SWA-01TP

25 TD-TP25 SWA-01TP

26 TD-TP26 SWA-01TP

27 TD-TP27 SWA-01TP

28 TD-TP28 SWA-01TP

23
29 AP-TP03 SWA-01TP

30 TD-TP29 SWA-01TP OFICINA 2

31 AP-TP01 SWA-01TP PASILLO

32 AP-TP02 SWA-01TP
SECRETARIA
33 TD-TP30 SWA-01TP

34 TD-TP31 SWA-01TP

35 TD-TP32 SWA-01TP
OFICINA 3
36 TD-TP33 SWA-01TP

37 TD-TP34 SWA-01TP

38 TD-TP35 SWA-01TP
OFICINA 1
39 TD-TP36 SWA-01TP

TABLA 10

4.4.2. TOMAS DE VOZ


PLANTA BAJA TOMAS DE VOZ

Nmero Toma Armario Secundario Localizacin

1 TV-PB01 SWA-02PB

2 TV-PB02 SWA-02PB
SALA 3D
3 TV-PB03 SWA-02PB

4 TV-PB04 SWA-02PB

5 TV-PB05 SWA-02PB RECEPCIN

6 TV-PB06 SWA-02PB

7 TV-PB07 SWA-02PB
SALA 2D
8 TV-PB08 SWA-02PB

9 TV-PB09 SWA-02PB

10 TV-PB10 SWA-02PB SALA DE CRISIS

24
11 TV-PB11 SWA-02PB

12 TV-PB12 SWA-02PB

13 TV-PB13 SWA-02PB

14 TV-PB14 SWA-02PB SEGURIDAD

15 TVD-PB01 SWA-02PB

16 TVD-PB02 SWA-02PB AUDITORIO

17 TVD-PB03 SWA-02PB

18 TVD-PB04 SWA-02PB

TABLA 11

PRIMERA PLANTA TOMAS DE VOZ

Nmero Toma Armario Secundario Localizacin

1 TV-PP01 SWA-02PP

2 TV-PP02 SWA-02PP

3 TV-PP03 SWA-02PP

4 TV-PP04 SWA-02PP OFICINA 4

5 TV-PP05 SWA-02PP

6 TV-PP06 SWA-02PP

7 TV-PP07 SWA-02PP

8 TV-PP08 SWA-02PP

9 TV-PP09 SWA-02PP SALA DE REUNIONES

10 TV-PP10 SWA-02PP

11 TV-PP11 SWA-02PP

12 TV-PP12 SWA-02PP OFICINA 5

13 TV-PP13 SWA-02PP

14 TV-PP14 SWA-02PP

25
15 TV-PP15 SWA-02PP

16 TV-PP16 SWA-02PP

17 TV-PP17 SWA-02PP

18 TV-PP18 SWA-02PP

19 TV-PP19 SWA-02PP

20 TV-PP20 SWA-02PP

21 TV-PP21 SWA-02PP

22 TV-PP22 SWA-02PP OFICINA 1

23 TV-PP23 SWA-02PP

24 TV-PP24 SWA-02PP

25 TV-PP25 SWA-02PP

26 TV-PP26 SWA-02PP

27 TV-PP27 SWA-02PP

28 TV-PP28 SWA-02PP

29 TV-PP29 SWA-02PP OFICINA 2

30 TV-PP30 SWA-02PP SECRETARIA

31 TV-PP31 SWA-02PP

32 TV-PP32 SWA-02PP
OFICINA 3
33 TV-PP33 SWA-02PP

34 TV-PP34 SWA-02PP

TABLA 12

SEGUNDA PLANTA TOMAS DE VOZ

Nmero Toma Armario Secundario Localizacin

1 TV-SP01 SWA-02SP OFICINA 4

2 TV-SP02 SWA-02SP

26
3 TV-SP03 SWA-02SP

4 TV-SP04 SWA-02SP

5 TV-SP05 SWA-02SP

6 TV-SP06 SWA-02SP

7 TV-SP07 SWA-02SP

8 TV-SP08 SWA-02SP

9 TV-SP09 SWA-02SP SALA DE REUNIONES

10 TV-SP10 SWA-02SP

11 TV-SP11 SWA-02SP

12 TV-SP12 SWA-02SP

13 TV-SP13 SWA-02SP
OFICINA 5
14 TV-SP14 SWA-02SP

15 TV-SP15 SWA-02SP

16 TV-SP16 SWA-02SP

17 TV-SP17 SWA-02SP

18 TV-SP18 SWA-02SP

19 TV-SP19 SWA-02SP

20 TV-SP20 SWA-02SP

21 TV-SP21 SWA-02SP

22 TV-SP22 SWA-02SP

23 TV-SP23 SWA-02SP

24 TV-SP24 SWA-02SP

25 TV-SP25 SWA-02SP

26 TV-SP26 SWA-02SP

27 TV-SP27 SWA-02SP OFICINA 1

27
28 TV-SP28 SWA-02SP

29 TV-SP29 SWA-02SP OFICINA 2

30 TV-SP30 SWA-02SP SECRETARIA

31 TV-SP31 SWA-02SP

32 TV-SP32 SWA-02SP
OFICINA 3
33 TV-SP33 SWA-02SP

34 TV-SP34 SWA-02SP

35 TV-SP35 SWA-02SP
OFICINA 1
36 TV-SP36 SWA-02SP

TABLA 13

TERCERA PLANTA TOMAS DE VOZ

Nmero Toma Armario Secundario Localizacin

1 TV-TP01 SWA-02TP

2 TV-TP02 SWA-02TP

3 TV-TP03 SWA-02TP

4 TV-TP04 SWA-02TP OFICINA 4

5 TV-TP05 SWA-02TP

6 TV-TP06 SWA-02TP

7 TV-TP07 SWA-02TP

8 TV-TP08 SWA-02TP

9 TV-TP09 SWA-02TP SALA DE REUNIONES

10 TV-TP10 SWA-02TP

11 TV-TP11 SWA-02TP
OFICINA 5
12 TV-TP12 SWA-02TP

13 TV-TP13 SWA-02TP

28
TV-TP14
14 SWA-02TP

15 TV-TP15 SWA-02TP

16 TV-TP16 SWA-02TP

17 TV-TP17 SWA-02TP

18 TV-TP18 SWA-02TP

19 TV-TP19 SWA-02TP

20 TV-TP20 SWA-02TP

21 TV-TP21 SWA-02TP

22 TV-TP22 SWA-02TP

23 TV-TP23 SWA-02TP OFICINA 1

24 TV-TP24 SWA-02TP

25 TV-TP25 SWA-02TP

26 TV-TP26 SWA-02TP

27 TV-TP27 SWA-02TP

28 TV-TP28 SWA-02TP

29 TV-TP29 SWA-02TP OFICINA 2

30 TV-TP30 SWA-02TP SECRETARIA

31 TV-TP31 SWA-02TP

32 TV-TP32 SWA-02TP
OFICINA 3
33 TV-TP33 SWA-02TP

34 TV-TP34 SWA-02TP

35 TV-TP35 SWA-02TP
OFICINA 1
36 TV-TP36 SWA-02TP

TABLA 14

29
4.4.3. TOTAL DE TOMAS DE VOZ Y DATOS

EDIFICIO IESS CONOCOTO


TOMAS DE TOMAS DE
UBICACIN
DATOS VOZ
PLANTA BAJA 22 18

PRIMERA PLANTA 37 34

SEGUNDA PLANTA 39 36

TERCERA PLANTA 39 36

TOTAL 137 124


TABLA 15

5. SISTEMA DE ALARMA CONTRA INCENDIOS

5.1. INTRODUCCIN

Todas las edificaciones en algn momento se ven expuestas a algn siniestro. Los accidentes suelen
ocurrir, pero hay que estar preparados para cuando eso ocurra. Por ello, todos los edificios deben de
contar con un sistema de alarma contra incendio que garantice la seguridad de proveedores,
empleados, y recursos tecnolgicos. Esto es una forma de brindar tranquilidad y estar preparados ante
cualquier inconveniente.

Los sistemas de alarma contra incendio, son fundamentales para la proteccin de plantas, edificios,
laboratorios, etc. Estos sistemas deben garantizar una respuesta rpida y efectiva ante cualquier
emergencia que se pudiera suscitar.

Se ha realizado el diseo de un sistema de alarma contra incendios para el edificio del IESS ubicado en
la ciudad de Sangolqu (Venezuela y Montfar), cantn Rumiahui, provincia de Pichincha. El mismo
que cuenta con los componentes esenciales para el correcto funcionamiento del sistema y que se
especificarn ms adelante.

5.2. DESARROLLO

Los dispositivos del sistema de alarma contra incendios ofrecen una gran seguridad y confiabilidad
gracias a las diferentes tecnologas que se encuentran en el mercado y que tenemos a la disposicin.
Para nuestro diseo utilizaremos los siguientes componentes:

CENTRAL DE ALARMA CONTRA INCENDIOS

30
Es un dispositivo electrnico que es el cerebro de nuestro sistema de alarma contra incendios
su funcin principal es el mantenimiento y comprobacin de diferentes dispositivos que
forman parte de un sistema de deteccin de incendios tales como: sensores de humo y
temperatura, estaciones manuales, luces estroboscpicas, entre otros.

SENSORES DE HUMO Y TEMPERATURA


Un sensor de humo y temperatura es un elemento que detecta la presencia de humo en el aire
y emite una seal avisando del peligro de incendio.

LUCES ESTROBOSCPICAS
Son dispositivos de iluminacin porttiles que emiten las luces que destellan de intensidad alta.

ESTACIONES MANUALES
Es un aparato que est diseado para ser activado en caso de incendio, tirando de una
manivela. Al ser activado el aparato informa de inmediato a la central de deteccin de
incendios.

5.3. ESPECIFICACIONES TCNICAS


EQUIPO DESCRIPCIN MODELO MARCA

CENTRAL DE INCENDIO
- Cuatro zonas de
iniciacin (expandibles a
ocho); hasta 20
detectores de humo de
dos cables por zona. FPD-7024 BOSCH
- Se convierte fcilmente
en direccionable con la
incorporacin de un
mdulo de expansin
mltiple D7039.

- Teclado alfanumrico
TECLADO LCD de doble lnea 32
caracteres.
- Leds identificadores de
alarma, problema,
supervisin y
silenciado. FMR-7033 BOSCH
- Direccionamiento por
Jumper.
- Mximo 4 por central
FPD-7024
- Distancia mxima
305m con cable
18AWG.

31
DETECTOR FOTOELCTRICO
DE HUMO Y TEMPERATURA
- Voltaje de entrada DC
DE 2 HILOS 12/32V
- Corriente de alarma 40-
80mA (DC12/32 V)
- Temperatura de
DHFK2 STARLIGH
operacin 10C-50C.
- rea de deteccin de
60m2 a 4m de altura.
- Proteccin de metal
para interferencias
electromagnticas

AVISADOR MANUAL - Avisadores manuales


DIRECCIONABLE metlicos.
- La serie de avisadores
manuales multiplex
FMM-7045 son
dispositivos de
inicializacin de alarma
de incendio listados FMM-7045 BOSCH
por la norma UL.
- Se pueden conectar
junto con otros
dispositivos multiplex
en el mdulo de
expansin D7039.

SIRENA CON LUZ


ESTROBOSCPICA
- Mltiple voltaje (12VDC
o 24VDC).
- Puntos de testeo de
voltaje. W-HSR BOSCH
- Ocho opciones de
intensidad de candelas.
- Tres seteos de
intensidad de audio.

MDULO DE EXPANSIN - Cuenta con dos buses


MLTIPLE mltiples clase B (estilo
4) (admite direcciones 9 D7039 BOSCH
a 255)
- Proporciona un bus
mltiple clase A (estilo

32
6) (admite direcciones 9
a 128).
- Ampla la cantidad de
cdigos de usuario a
100 PIN.
- Aumenta la memoria
intermedia histrica a
499 eventos.
- Compatible con RPS

ROLLO DE CABLE - Cable unifilar blindado


2x18.AWG.FTP DE 300m Honeywell de 2 o 4
conductores calibre 18
AWG, para instalacin HONEYWELL
HONFPL2X18
de sistemas de alarma GENESIS
de incendio que
requieren blindaje.
- Carrete de 300m y
150m
TABLA 16

5.4. DISTRIBUCCIN
5.4.1. SENSORES DE HUMO Y TEMPERATURA

PLANTA BAJA SENSORES DE HUMO Y TEMPERATURA

Nmero Toma Localizacin

1 SHT-01PB SEGURIDAD

2 SHT-02PB ESPERA

3 SHT-03PB COPIADO

4 SHT-04PB SALA 3D

5 SHT-05PB CUARTO

6 SHT-06PB
SALA 2D
7 SHT-07PB

33
8 SHT-08PB SALA DE CRISIS

9 SHT-09PB PASILLO

COMEDOR DE
10 SHT-10PB
PERSONAL

11 SHT-11PB COCINA

12 SHT-12PB BODEGA

13 SHT-13PB CORREDOR

14 SHT-14PB
AUDITORIO
15 SHT-15PB

16 SHT-16PB CONTROL ELCTRICO

CUARTO DE
17 SHT-17PB
TELECOMUNICACIONES

TABLA 17

PRIMERA PLANTA SENSORES DE HUMO Y TEMPERATURA

Nmero Toma Localizacin

1 SHT-01PP
OFICINA 5
2 SHT-02PP

3 SHT-03PP SALA DE REUNIONES

4 SHT-04PP
OFICINA 4
5 SHT-05PP

DUCTOS DE
6 SHT-06PP
INSTALACIONES

7 SHT-07PP

8 SHT-09PP PASILLO

9 SHT-12PP

9 SHT-10PP SECRETARIA

34
10 SHT-11PP OFICINA 2

12 SHT-08PP

13 SHT-13PP OFICINA 1

14 SHT-14PP

CUARTO DE
15 SHT-15PP
TELECOMUNICACIONES

TABLA 18

SEGUNDA PLANTA SENSORES DE HUMO Y TEMPERATURA

Nmero Toma Localizacin

1 SHT-01SP
OFICINA 5
2 SHT-02SP

3 SHT-03SP SALA DE REUNIONES

4 SHT-04SP
OFICINA 4
5 SHT-05SP

DUCTOS DE
6 SHT-06SP
INSTALACIONES

7 SHT-07SP

8 SHT-09SP PASILLO

9 SHT-12SP

10 SHT-10SP SECRETARIA

11 SHT-11SP OFICINA 2

12 SHT-08SP

13 SHT-13SP OFICINA 1

14 SHT-14SP

CUARTO DE
15 SHT-15SP
TELECOMUNICACIONES

35
TABLA 19

TERCERA PLANTA SENSORES DE HUMO Y TEMPERATURA

Nmero Toma Localizacin

1 SHT-01TP
OFICINA 5
2 SHT-02TP

3 SHT-03TP SALA DE REUNIONES

4 SHT-04TP
OFICINA 4
5 SHT-05TP

DUCTOS DE
6 SHT-06TP
INSTALACIONES

7 SHT-07TP

8 SHT-09TP PASILLO 1

9 SHT-12TP

10 SHT-10TP SECRETARIA

11 SHT-11TP OFICINA 2

12 SHT-08TP

13 SHT-13TP OFICINA 1

14 SHT-14TP

CUARTO DE
15 SHT-15TP
TELECOMUNICACIONES

TABLA 20

5.4.2. ESTACIONES MAUALES

PLANTA BAJA ESTACIONES MANUALES

Nmero Toma Localizacin

1 EM-01PB PASILLO

36
2 EM-02PB ESPERA

3 EM-03PB ESPERA

TABLA 21

PRIMERA PLANTA ESTACIONES MANUALES

Nmero Toma Localizacin

1 EM-01PP
PASILLO
2 EM-02PP

CERCA DEL
3 EM-03PP
ASCENSOR

TABLA 21

SEGUNDA PLANTA ESTACIONES MANUALES

Nmero Toma Localizacin

1 EM-01SP
PASILLO
2 EM-02SP

CERCA DEL
3 EM-03SP
ASCENSOR

TABLA 22

TERCERA PLANTA ESTACIONES MANUALES

Nmero Toma Localizacin

1 EM-01TP
PASILLO
2 EM-02TP

CERCA DEL
3 EM-03TP
ASCENSOR

TABLA 23

37
5.4.3. LUCES ESTROBOSCPICAS

PLANTA BAJA LUCES ESTROBOSCPICAS

Nmero Toma Localizacin

1 LE-01PB PASILLO

2 LE-02PB ESPERA

3 LE-03PB ESPERA

TABLA 24

PRIMERA PLANTA LUCES ESTROBOSCPICAS

Nmero Toma Localizacin

1 LE-01PP
PASILLO
2 LE-02PP

3 LE-03PP ESCALERAS

CERCA DEL
4 LE-04PP
ASCENSOR

TABLA 25

SEGUNDA PLANTA LUCES ESTROBOSCPICAS

Nmero Toma Localizacin

1 LE-01SP
PASILLO
2 LE-02SP

3 LE-03SP ESCALERAS

CERCA DEL
4 LE-04SP
ASCENSOR

TABLA 26

TERCERA PLANTA LUCES ESTROBOSCPICAS

Nmero Toma Localizacin

38
1 LE-01TP
PASILLO
2 LE-02TP

3 LE-03TP ESCALERAS

CERCA DEL
4 LE-04TP
ASCENSOR

TABLA 27

5.4.4. TOTAL DE EQUIPOS USADOS


TOTAL DE SENSORES DE HUMO Y TEMPERATURA, ESTACIONES MANUALES, LUCES
ESTROBOSCPICAS

EDIFICIO IESS CONOCOTO


SENSORES DE
ESTACIONES LUCES
UBICACIN HUMO Y
MANUALES ESTROBOSCPICAS
TEMPERATURA
PLANTA BAJA 17 3 3

PRIMERA PLANTA 15 3 4

SEGUNDA PLANTA 15 3 4

TERCERA PLANTA 15 3 4

TOTAL 62 12 15
TABLA 28

6. SISTEMA DE ALARMA CONTRA ROBO

6.1. INTRODUCCIN
Los sistemas de alarma contra robo son populares y utilizados por muchas personas y
establecimientos. Hoy en da es comn hablar de instalar una alarma en una casa y bastante
ms usual en un comercio u oficina.

El objetivo de este sistema de alarma contra robo es prevenir el delito de robo contra la
propiedad, disuadir al potencial intruso y dar aviso a las autoridades correspondientes. Ningn
sistema de alarma tiene la capacidad de evitar el robo, pero esta es una consecuencia directa
de su uso. Es decir, que un sistema de alarma slo podr evitar un delito si cumple con las
caractersticas de disuasin y aviso.

39
Para que pueda cumplir con este objetivo, se hace imprescindible un diseo del sistema que
incluye un relevamiento de la propiedad en cuestin, la utilizacin adecuada de los mejores
dispositivos del mercado y una correcta instalacin. A esto hay que agregarle un uso y un
mantenimiento correctos.

Como todo sistema que interacta con personas, se debe adecuar a las costumbres de stas y
se dise de tal manera que no dependa de la voluntad de stas, sino que acte por s solo
cumpliendo su funcin. El sistema debe entonces ser capaz de verificar el estado de las reas
protegidas y a s mismo, avisando de algn modo al usuario o al departamento tcnico de
anomalas o situaciones anormales.

El usuario a su vez deber entender que dicho sistema necesita encenderse en el momento
que se quiera proteger la propiedad y deber estar alerta a los avisos que este haga,
entendiendo que ignorar un aviso del sistema puede resultar en la prdida o disminucin de
la seguridad.

6.2. DESARROLLO

NORMA NFPA 731

La norma NFPA brinda estndares para la instalacin de sistemas de seguridad electrnicos.

La norma NFPA 731, denominada Estndares para la instalacin de sistemas de seguridad


electrnicos, comienza a ser adoptado por las empresas aseguradoras.

El documento establece los requerimientos mnimos para la incorporacin de las ltimas tecnologas
en cuanto a sistemas de alarmas para inmuebles no-residenciales. Los parmetros establecidos en este
caso por esa asociacin no slo se refieren a la deteccin de incendios, sino tambin a controles de
acceso, circuitos cerrados de televisin, deteccin de intrusos, biometra, tipos de alarmas e incluso la
disposicin de los cableados correspondientes a cada sistema.

Normas como sta son de libre adhesin, pero en la medida en que sean acatadas por sectores
poderosos tales como las industrias aseguradora, bancaria o turstica, su conocimiento y aplicacin se
harn indispensables. Sus efectos no sern vistos de inmediato sino en el mediano plazo, cuando las
instituciones de los distintos niveles gubernamentales orienten sus compras y contratos de servicio
segn sus dictados. No obstante, mientras la industria estadounidense se reacomoda es importante
que los pases latinoamericanos estn alertas.

La norma NFPA 731, que suministra especificaciones para la instalacin de sistemas y dispositivos
electrnicos de seguridad en los tipos de instalaciones incluidas, est siendo desarrollada como una
norma y es similar a la norma NFPA 72, Cdigo nacional de alarma contra incendios.

40
El objetivo de la norma NFPA 731 tambin incluye los requisitos para el cableado, fuentes de energa,
supervisin, prueba y mantenimiento, control de acceso y vigilancia.

La norma NFPA 731 abarca el Control del acceso, el sistema de CCTV y la integracin de estos sistemas
como tambin la interface de los sistemas de seguridad de edificios con los sistemas de seguridad
humana.

La norma NFPA 731 no est diseada para requerir un nivel de seguridad de edificios; en realidad
establece los niveles mnimos requeridos de desempeo, el punto de superfluidad y calidad de las
instalaciones. No establece as los nicos mtodos por los que se deben alcanzarse los requisitos.

Los requisitos de la norma NFPA 731 estn diseados para aumentar la calidad y confiabilidad de las
instalaciones y reducir la desmesurada cantidad de falsas alarmas debido a una pobre instalacin,
aplicacin y capacitacin; estos son:

SEGURIDAD ELECTRNICA.

Su restauracin a la normalidad se indicar de forma automtica en 90 segundos


Cuando el cableado de interconexin al teclado y ordenador(PC) no tiene que ser supervisado
cuando no excede los 2.4m de largo
Cuando el fallo del cableado es causado por el mal funcionamiento de los componentes.
Un circuito de retardo de entrada se utiliza en un sistema, subsistema o particin.
El tiempo de entrada / salida no ser superior a 240 segundos
Los dispositivos se instalarn segn las instrucciones del fabricante.
La cobertura y el espaciamiento de los dispositivos debern estar basados en la distancia
prevista segn lo especificado por el diseador para el usuario final.
Detectores estructurales para exteriores debern incluir la siguiente: audio, contactos fibra
ptica sensores de proximidad y sensores de choque
Sistemas de deteccin de interior para puertas, ventanas y otras aperturas de sistemas de
proteccin debe incluir: la creacin de bandas ranuradas, cordn, cableado abierto, pantallas,
incluyendo enclavijar la madera y el tipo de malla.
sensor de rotura de cristal incluir los siguientes tipos: vibracin y audio
Los detectores de movimiento debern incluir tambin: dos o ms tecnologas, microondas,
infrarrojos pasivos (PIR)
Las posiciones de los sensores se controlarn en su caso por el controlador de extremo de la
cabeza o un sistema de deteccin de instrucciones integrado a fin de notificar al usuario del
sistema que ha ocurrido un evento
El sensor de posicin se monta de tal manera que ninguna parte del rea se puede abrir mayor
que 15,24 cm antes de activar el sensor.

Los requisitos propuestos de la NFPA 731 incluyen: Los planes del sistema de seguridad de edificios
debern ser desarrollados por personas con experiencia en el diseo, aplicacin, instalacin y
evaluacin adecuados de los sistemas de seguridad de edificios. Se deber identificar al diseador del
sistema en los documentos de diseo del sistema. Se debern suministrar pruebas de su aptitud cuando

41
fuera as requerido por una autoridad competente. Ejemplos de personal calificado incluyen, pero no
se limitan a:

Personal certificado y capacitado de los fabricantes de equipos.


Personal autorizado y certificado por el estado o la autoridad local.
Personal certificado por un programa de acreditacin aceptado por la AHJ.

El comit tcnico de la norma NFPA 731 ha decidido que, en su primera edicin, la norma NFPA 731
slo abarcar los edificios protegidos desde la lnea de la propiedad hacia el interior del edificio y no
abarcar la operacin de la Estacin Central ya que se relaciona con el monitoreo de sealizacin de
seguridad.

6.3. ESPECIFICACIONES TCNICAS


EQUIPOS ESPECIFICACIONES

CENTRAL DSC PC1832


32 zonas
Soporta teclado LED LCD
Teclado LCD Alfanumrico.
Incluye Comunicador Digital.
2 PGM.
8 Particiones.
Incluye transformador

SENSOR MAGNETICO

Utilizacin para puertas y ventanas


Alimentacin 3Vcc
suministrados por la unidad
principal (no incluida)

SENSOR DE MOVIMIENTO DSC


Dimensiones (117mmx36mm)
Voltaje operacional 9V14 V MQ*
Corriente de reserva 2.5mA
Corriente en alarma 2.5mA
Corriente de prueba 5.0mA
Potencia de contacto 100mA a
24Vcc.

42
Lmites de temperatura de
operacin 32 F - 120 F
(0 C - 49 C)
Inmunidad a la radiofrecuencia y a
las ondas electromagnticas 50
V/m desde 0.01 hasta 1,200 MHz
Humedad relativa 5% - 95%
Inmunidad a la corriente esttica
25kV
Inmunidad a las corrientes
transitorias 2.4kV a 1.2 J
Velocidad de deteccin de
movimiento al caminar (0.15 - 3
m/s)

TECLADO LED DSC


Dimensiones 154 mm x 113 mm x
20,5 mm
rea visible del LCD 99 mm x 24
mm
Consumo de corriente 125mA
(Mx.)
Tensin 12 VDC Nominal
Temperatura de operacin 32 a
120 F (0 a 49 C)
Humedad relativa 5 a 93%
Cinco teclas de funcin
programables

BATERA DSC
Duracin de 8 horas
Voltaje 12V
Capacidad 5.0
Peso 1.56Kg
Dimensiones 90*70*101*107

BOCINA DSC

43
2 Tonos.
115 dB.
20 Watts.
Color Blanco.

TRANSFORMADOR DSC

110v a 12v
Peso 6.5 libras (3 kg)
Dimensiones (27930084mm)

UTP Cat3-4PARES Conductor de cobre slido calibre


0,51 mm (24 AWG) aislacin PE
(Polietileno), pareados y cableados
segn protocolo, cubierta externa
de PVC, no propagante de llama y
auto extinguible.

UTP Cat3-12PARES Adecuado para aplicaciones de las


comunicaciones.
Adecuado para Telefona y
Sistemas de Seguridad.
Cable Categora-3 de par trenzado
sin blindaje.
Colores permiten identificar
fcilmente.
Conductores de cobre slido
24AWG.
Excelente atenuacin y crosstalk.
Excede normas EIA/TIA 568B.2-1.
Listado ETL, tipo CM.
Se suministra en rollo de 305m

44
UTP Cat3-25PARES Conductores de cobre slido
Aislamiento de PVC
Conductores pareados y cableados
Cubierta exterior de PVC
Sin blindar

TABLA 29

6.4. DISTRIBUCIN

DISTRIBUCIN GLOBAL

PISOS Sensores Total

Movimiento 9
PLANTA BAJA
Magnticos 8

Teclado 1

Bocina 1

PRIMERA PLANTA Movimiento 3

Magnticos 2

SEGUNDA PLANTA Movimiento 3

Magnticos 2

TERCERA PLANTA Movimiento 3

Magnticos 2

TABLA 30

DISTIBUCION INDIVIDUAL

PLANTA BAJA

Sensores Nomenclatura Ubicacin

movimiento SM-01-PB CUARTO DE TELECOMUNICACIONES

movimiento SM-02-PB SALA 2D

movimiento SM-03-PB SALA 2D

movimiento SM-04-PB ESPERA

45
movimiento SM-05-PB ESPERA

movimiento SM-06-PB ESPERA

movimiento SM-07-PB AUDITORIO

movimiento SM-08-PB AUDITORIO

movimiento SM-09-PB VACIO

magntico SMG-01-PB VACIO

magntico SMG-02-PB AUDITORIO

magntico SMG-03-PB AUDITORIO

magntico SMG-04-PB CUARTO DE TELECOMUNICACIONES

magntico SMG-05-PB SEGURIDAD

magntico SMG-06-PB CONTROL ELECTRICO

magntico SMG-07-PB SALA 2D

magntico SMG-08-PB BODEGA-COCINA

bocina SR-01-PB SEGURIDAD

teclado TE-01-PB ESPERA

PRIMERA PLANTA

Sensores Nomenclatura Ubicacin

movimiento SM-01-P1 CUARTO DE TELECOMUNICACIONES

movimiento SM-02-P1 ESPERA

movimiento SM-03-P1 ESPERA

magntico SMG-01-P1 CUARTO DE TELECOMUNICACIONES

magntico SMG-02-P1 SEGURIDAD

SEGUNDA PLANTA

Sensores Nomenclatura Ubicacin

movimiento SM-01-P2 CUARTO DE TELECOMUNICACIONES

movimiento SM-02-P2 ESPERA

movimiento SM-03-P2 ESPERA

magntico SMG-01-P2 CUARTO DE TELECOMUNICACIONES

46
magntico SMG-02-P2 SEGURIDAD

TERCERA PLANTA

Sensores Nomenclatura Ubicacin

movimiento SM-01-P3 CUARTO DE TELECOMUNICACIONES

movimiento SM-02-P3 ESPERA

movimiento SM-03-P3 ESPERA

magntico SMG-01-P3 CUARTO DE TELECOMUNICACIONES

magntico SMG-02-P3 SEGURIDAD

TABLA 31

7. SISTEMA DE CCTV

7.1. INTRODUCCIN
Un sistema de CCTV realiza la supervisin de aquellos puntos coherentes con la seguridad como son los
puntos vulnerables del recinto de las instalaciones. Las imgenes obtenidas de dichos puntos podrn
ser visualizadas de forma automtica, como resultado de una alarma.

Las funcionalidades bsicas del sistema de CCTV por tanto son las siguientes:

Seleccin de imgenes captadas por una cmara determinada para ser visualizadas en un
monitor.
Seleccin de imgenes captadas por varias cmaras para ser visualizadas
simultneamente.
Posibilidad de secuenciamiento de las imgenes captadas por un grupo de cmaras.
Grabacin de las imgenes captadas por una o varias cmaras.
Reproduccin de grabaciones de seguridad de cualquier cmara.
Gestin de alarmas y anomalas que se puedan producir en el sistema.

El despliegue de un sistema CCTV IP resulta ms sencillo y econmico que un sistema analgico, pues
si las cmaras disponen de alimentacin por PoE (Power Over Ethernet) estas se alimentan con el
mismo cable de datos o cable UTP con el que se transmite la imagen.

Por lo que, si la distancia hasta la cmara no sobrepasa los 100m (el mximo de distancia para el
correcto funcionamiento del cable UTP), slo se requiere el tendido de un nico cable.

Un sistema CCTV de tecnologa IP adopta los beneficios analgicos de los tradicionales CCTV con las
ventajas digitales de las redes de comunicacin IP, permitiendo la inspeccin local de las imgenes, as
como su tratamiento digital.

47
7.2. DESARROLLO

NORMA NFPA 731

La norma NFPA brinda estndares para la instalacin de sistemas de seguridad electrnicos.

La norma NFPA 731, denominada Estndares para la instalacin de sistemas de seguridad


electrnicos, comienza a ser adoptado por las empresas aseguradoras.

El documento establece los requerimientos mnimos para la incorporacin de las ltimas tecnologas
en cuanto a sistemas de alarmas para inmuebles no-residenciales. Los parmetros establecidos en este
caso por esa asociacin no slo se refieren a la deteccin de incendios, sino tambin a controles de
acceso, circuitos cerrados de televisin, deteccin de intrusos, biometra, tipos de alarmas e incluso la
disposicin de los cableados correspondientes a cada sistema.

Normas como sta son de libre adhesin, pero en la medida en que sean acatadas por sectores
poderosos tales como las industrias aseguradora, bancaria o turstica, su conocimiento y aplicacin se
harn indispensables. Sus efectos no sern vistos de inmediato sino en el mediano plazo, cuando las
instituciones de los distintos niveles gubernamentales orienten sus compras y contratos de servicio
segn sus dictados.

No obstante, mientras la industria estadounidense se reacomoda es importante que los pases


latinoamericanos estn alertas.

La norma NFPA 731, que suministra especificaciones para la instalacin de sistemas y dispositivos
electrnicos de seguridad en los tipos de instalaciones incluidas, est siendo desarrollada como una
norma y es similar a la norma NFPA 72, Cdigo nacional de alarma contra incendios.

El objetivo de la norma NFPA 731 tambin incluye los requisitos para el cableado, fuentes de energa,
supervisin, prueba y mantenimiento, control de acceso y vigilancia.

La norma NFPA 731 abarca el Control del acceso, el sistema de CCTV y la integracin de estos sistemas
como tambin la interface de los sistemas de seguridad de edificios con los sistemas de seguridad
humana.

La norma NFPA 731 no est diseada para requerir un nivel de seguridad de edificios; en realidad
establece los niveles mnimos requeridos de desempeo, el punto de superfluidad y calidad de las
instalaciones. No establece as los nicos mtodos por los que se deben alcanzarse los requisitos.

Los requisitos de la norma NFPA 731 estn diseados para aumentar la calidad y confiabilidad de las
instalaciones y reducir la desmesurada cantidad de falsas alarmas debido a una pobre instalacin,
aplicacin y capacitacin; estos son:

CAMARAS.

Todas las cmaras debern estar instaladas para el mismo propsito.

48
Todas las cmaras se instalarn segn las instrucciones del fabricante.
Las cmaras se instalarn por las siguientes condiciones ambientales que no afecten a sus
actividades: la formacin de hielo, los ngulos de la luz del sol, las temperaturas extremas, la
carga del viento, la lluvia.
El cable coaxial debe tener una impedancia de 75 ohms.
Cuando se utiliza UTP para transmisin de seal de vdeo, la distancia mxima no exceder las
instrucciones del fabricante.
La seguridad local electrnica elctrica y los cables del sistema deben ser del calibre apropiado,
hilos, aislamiento y las propiedades elctricas segn lo especificado por el fabricante del
equipo.
Un bucle de servicio mnimo de 15,24 cm deber ser de al panel de control y recintos utilizados
para las terminaciones de cableado.
Un bucle de servicio mnimo ser de 15,24 cm en las terminaciones de campo.

Los requisitos propuestos de la NFPA 731 incluyen: Los planes del sistema de seguridad de edificios
debern ser desarrollados por personas con experiencia en el diseo, aplicacin, instalacin y
evaluacin adecuados de los sistemas de seguridad de edificios. Se deber identificar al diseador del
sistema en los documentos de diseo del sistema.

Se debern suministrar pruebas de su aptitud cuando fuera as requerido por una autoridad
competente. Ejemplos de personal calificado incluyen, pero no se limitan a:

Personal certificado y capacitado de los fabricantes de equipos.


Personal autorizado y certificado por el estado o la autoridad local.
Personal certificado por un programa de acreditacin aceptado por la AHJ.

El comit tcnico de la norma NFPA 731 ha decidido que, en su primera edicin, la norma NFPA 731
slo abarcar los edificios protegidos desde la lnea de la propiedad hacia el interior del edificio y no
abarcar la operacin de la Estacin Central ya que se relaciona con el monitoreo de sealizacin de
seguridad.

49
7.3. ESPECIFICACIONES TCNICAS
EQUIPOS ESPECIFICACIONES

DVR PANASONIC
Disco duro de 1Tera
El doble de su capacidad de
grabacin con la funcin de
registro largo de Panasonic
Grabar hasta 684 Horas en HD
vs 259 horas en modo normal

CMARA HD PANASONIC

Utilizacin para puertas y


ventanas
Alimentacin 3Vcc
suministrados por la unidad
principal (no incluida)
Exteriores

CMARA IP DOMO PANASONIC


Interiores
Varias transmisiones de vdeo,
incluyendo H.264 y JPEG.
Nuevo sensor MOS de 1,3
megapxeles de alta
sensibilidad.
Transmisin en tiempo real
(hasta 30 ips) en HD (720p).

Rj-45
Se utiliza para interconectar las
computadoras en redes locales
(LAN) en interiores de oficinas,
escuelas, hogares, etc.
Conexin de 8 pines.

UTP Cat 5e
UTP con espectro de 100MHz
Distancia 100m
Aplicacin LAN 100Base-T
Blindado
Impedancia de 100omhs

50
4 pares

PATCH CORD PANDUIT

Cable de conexin UTP Cat 5e


De UL / CE / ROHS enumeran
EIA / TIA 568A (B) Estndar
Cobre puro
Cable de conexin de prueba se ha
superado

SWITCH PANDUIT

Conmutador Switch. PoE+ con 52


puertos en total: 48 puertos PoE+2
SFP Gigabit 10/100/100+2 Puertos
Rj45 1/10GBASE-T

PATCH PANEL PANDUIT

Panel de 48 Puertos Cat 6 con


montaje en rack. Redes
Gigabit/Ethernet. Cumple Normas
EIA/TIA 568B

ORGANIZADOR DE CABLES PANDUIT

Organizador de cables Horizontal


1U, para gabinetes y racks 19"

TABLA 32

51
7.4. DISTRIBUCIN

DISTRIBUCIN GLOBAL

PISOS Cmaras Total

PLANTA BAJA Interior 6

Exterior 1

PRIMERA PLANTA Interior 3

SEGUNDA PLANTA Interior 3

TERCERA PLANTA Interior 3

TABLA 33

DISTIBUCION INDIVIDUAL

PLANTA BAJA

Cmaras Nomenclatura Ubicacin

interior CV-PB-01 CUARTO DE TELECOMUNICACIONES

interior CV-PB-02 ESPERA

interior CV-PB-03 AUDITORIO

interior CV-PB-04 AUDITORIO

interior CV-PB-05 ESPERA

interior CV-PB-06 ESPERA

exterior CV-PB-07 HALL DE ACCESO

PRIMERA PLANTA

Cmaras Nomenclatura Ubicacin

interior CV-PP-01 ESPERA

interior CV-PP-02 ESPERA

interior CV-PP-03 CUARTO DE TELECOMUNICACIONES

SEGUNDA PLANTA

Cmaras Nomenclatura Ubicacin

52
interior CV-SP-01 ESPERA

interior CV-SP-02 ESPERA

interior CV-SP-03 CUARTO DE TELECOMUNICACIONES

TERCERA PLANTA

Cmaras Nomenclatura Ubicacin

interior CV-TP-01 ESPERA

interior CV-TP-02 ESPERA

interior CV-TP-03 CUARTO DE TELECOMUNICACIONES

TABLA 34

53

You might also like