You are on page 1of 2

PRELIMINARY REPORT OF INSPECTION

Start Date : March 01, 2017


Location : PT Saipem Indonesia Karimun Branch
Yard & Workshop

A. Equipment data
1) Owner : PT Saipem Indonesia Karimun Branch
2) Owner Serial No. : as listed in the below table
B. Inspection Result
1) Inspection Type : Visual Inspection, Function Test, Load Test
2) Inspection List

Asset No. Function Visual Load Results


No. Description Remarks
S/N. Test Inspection Test
1 ELECTRIC OVERHEAD AZ 309178 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2381/2010
2 ELECTRIC OVERHEAD AZ 309179 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2382/2010
3 ELECTRIC OVERHEAD AZ 309183 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2386/2010
4 ELECTRIC OVERHEAD AZ 309181 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2384/2010
5 ELECTRIC OVERHEAD AZ 309185 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2388/2010
6 ELECTRIC OVERHEAD AZ 309184 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2387/2010
7 ELECTRIC OVERHEAD AZ 309186 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2389/2010
8 ELECTRIC OVERHEAD AZ 309190 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2393/2010
Page 1 of 2
PT. RIGSPEK PERKASA Updated on March 20, 2017
Komplek Kawasan Industri Sekupang
Kav. No.13, Batam 29428, Indonesia
Tel : +62 (0) 778 324747 / 324749
Fax : +62 (0) 778 321338
Email : sales@rigspekperkasa.com
Website : www.rigspekperkasa.com
9 ELECTRIC OVERHEAD AZ 309904 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2575/2011
10 ELECTRIC OVERHEAD AZ 309191 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2394/2010
11 GARUDA SKY TOWER AZ 303370 Finding Ok Ok NIL Wind speed indicator did not function, Crane document (Inspection
CRANE 01-12 Certificate and Manual) not available in Operator Cabin
12 ELECTRIC OVERHEAD AZ 309137 Ok Ok Ok Satisfactory -
TRAVELLING CRANE 2543/2010
13 TRUCK with CRANE- AZ 309120 Finding Ok Ok NIL The spring on Safety Latch of Load Hook did not function
KNUCKLE BOOM 3220780
14 TRUCK with CRANE- AZ 309845 Ok Ok Ok Satisfactory -
KNUCKLE BOOM 3221099
15 MAN LIFT-TELESCOPIC AZ 308942 Ok Ok Ok Satisfactory -
BOOM/CHERRY PICKER AD122382
16 FM GRU TOWER CRANE AZ 303333 Ok Ok Ok Satisfactory -
17485
17 ROUGH TERRAIN AZ 308662 Due Finding Due NIL Hydraulic Leakage Found on Boom Length Extension Cylinder,
CRANE TELESCOPIC 228897 Recommended Recalibration of Main Hook and Auxiliary Hook Load
BOOM Cell (About 1.9 t error found)

Prepared by,

Hendra

Page 2 of 2
PT. RIGSPEK PERKASA Updated on March 20, 2017
Komplek Kawasan Industri Sekupang
Kav. No.13, Batam 29428, Indonesia
Tel : +62 (0) 778 324747 / 324749
Fax : +62 (0) 778 321338
Email : sales@rigspekperkasa.com
Website : www.rigspekperkasa.com

You might also like