PRODUCT HIGHLIGHTS
// Benets // Performance Assurance Certication (PAC)
- Low fuel consumtion - Engine-generator set tested to ISO 8528-5 for transient
- Optimized system integration ability response
- High reliability - 75% load factor
- High availability of power - Veried product design, quality and performance integrity
- Long maintenance intervals - All engine systems are prototype and factory tested
APPLICATION DATA
// Engine // Liquid Capacity (Lubrication)
All data refers only to the engine and is based on ISO standard conditions (25C and 100m above sea level).
Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml.
All fuel consumption values refer to rated engine power.
3 / // / MTU 16V4000 DS2250 / 50 Hz / 380V - 11kV
// Engine
// Generator
NEMA MG1, BS5000, ISO, DIN EN and No load to full load regulation Marathon low voltage generator
IEC standards 0,25% voltage regulation no load to Leroy Somer generator
Self-ventilated full load Oversized generator
Superior voltage waveform Brushless alternator with brushless Medium voltage generator
Solid state, volts-per-Hertz regulator pilot exciter
4 pole, rotating eld
Sustained short circuit current of up
to 250% of the rated current for up
to 10 seconds (marathon generator)
Sustained short circuit current of up
to 300% of the rated current for up to
10 seconds (Leroy Somer generator)
// Cooling System
Pre-wired control cabinet for easy Basler controller Different expansion modules
application of customized controller Deif controller Remote annunciator
(V1+) Complete system metering Daytank control
Island operation (V2) Digital metering Generator winding temperature
Automatic mains failure operation Engine parameters monitoring
with ATS (V3a) Generator Protection Functions Generator bearing temperature
Automatic mains failure operation Engine protection monitoring
incl. control of generator and mains SAE J1939 engine ECU Differential protection with
breaker (V3b) communications multi-finction protection relay
Island parallel operation of multiple Parametrization software Modbus RTU-TCP gateway
gensets (V4) Multilingual capability
Automatic mains failure operation Multiple programmable contact inputs
with short (< 10s) mains parallel Multiple contact outputs
overlap synchronization (V5) Event recording
Mains parallel operation of a single IP 54 front panel rating with
genset (V6) integrated gasket
Mains parallel operation of multiple
gensets (V7)
// Fuel System
// Starting/Charging System
Welded base frame Resilient engine and generator Modular base frame design
mounting
// Exhaust System
Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design.
See website for unit specic template drawings.
SOUND DATA
// Consult your local MTU Onsite Energy distributor for sound data.
EMISSIONS DATA
// Consult your local MTU Onsite Energy distributor for emissions data.
www.mtuonsiteenergy.com