[SprinklerSystemandWaterSpraySystemDevices](Piping,SprinklerSystem)
MetallicSprinklerPipe
SeeGeneralInformationforPiping,SprinklerSystem
USEANDINSTALLATION
Thiscategorycoversmetallicsprinklerpipeintendedforuseinwaterbasedfireprotectionsystemsforwaterdistributionortrimapplications.
Thispipemaybeusedinwet,preaction,delugeordrypipetypesprinklersystemswheninstalledinaccordancewiththefollowing:
ANSI/NFPA13,"InstallationofSprinklerSystems"
ANSI/NFPA13D,"InstallationofSprinklerSystemsinOneandTwoFamilyDwellingsandManufacturedHomes"
ANSI/NFPA13R,"InstallationofSprinklerSystemsinResidentialOccupanciesuptoandIncludingFourStoriesinHeight"
ANSI/NFPA14,"InstallationofStandpipeandHoseSystems"
ANSI/NFPA15,"WaterSprayFixedSystemsforFireProtection"
ANSI/NFPA16,"InstallationofFoamWaterSprinklerandFoamWaterSpraySystems"
ANSI/NFPA750,"WaterMistFireProtectionSystems"
InaccordancewiththereferencedNFPAStandards,thepipesizesinstalledtodistributewatertothesprinklersshouldbenotlessthan1in.
nominalforsteelpipeand3/4in.forcopperpipe.
Asindicatedintheindividualcertifications,Schedule10andSchedule40steelpipeandothersteelpipehavinglesserwallthicknessesthan
unthreadedSchedule40pipeiscoveredunderthiscategory.Cutgrooved,rollgroovedandplainendpipeisintendedtobejoinedbycertified
rubbergasketedfittings(seeVIZM)orweldedoutletfittings(seeVIZU),whichhavebeeninvestigatedforcompatibilitywiththespecificpipe.
Plainendpipemayalsobejoinedbyweldingendtoendorweldingtoflanges.
Schedule10and40steelpipeincorporatesdimensionsandmaterialsspecifiedinASTMA53,"StandardSpecificationforPipe,Steel,Blackand
HotDipped,ZincCoated,WeldedandSeamless,"ASTMA135,"StandardSpecificationforElectricResistanceWeldedSteelPipe,"orASTM
A795,"StandardSpecificationforBlackandHotDippedZincCoated(Galvanized)WeldedandSeamlessSteelPipeforFireProtectionUse."
Schedule40pipeendsareintendedtobethreaded,rollgrooved,cutgrooved,orplain.Schedule10pipeendsareintendedtoberollgrooved
orplain.
SteelpipehavinglesserwallthicknessesthanunthreadedSchedule40pipemaybethreaded,rollgrooved,orplainendasindicatedinthe
individualcertifications.ThreadingrequirestheuseofthreadgaugesconformingtothedimensionsofASMEB1.20.1,"PipeThreads,General
Purpose."Thispipehasbeeninvestigatedforbothmechanicalstrengthandrelativecorrosionresistanceexpressedintermsofacorrosion
resistanceratio(CRR).Thisratioforeachsizepipeisdefinedasfollows:
Where:X40=ThicknessofSchedule40pipeunderthefirstexposedthread.The"firstexposedthread"istheminimumpipethicknessexposed
tobothinteriorandexteriorcorrosionandoccursatthethreadedjointassemblyatalinedefinedbythethreadwidth,justbeforethepipe
engagesthefitting.
X=Thicknessofthecertifiedpipemeasuredeitherunderthefirstexposedthreadforthreadedpipeoratthethinnestwallsectionfor
unthreadedpipe.
TheCRRwillbegreaterthan1.00whenthewallthicknessofthecertifiedpipeisgreaterthanthewallthicknessofSchedule40pipeunderthe
firstexposedthread,andlessthan1.00whenthecertifiedpipewallisthinnerthanthewallthicknessofSchedule40pipeunderthefirst
exposedthread.
Thecorrosionperformanceofsteelpipecanvarydependingonthecompositionofthesteelofwhichitisformed,thecompositionofthe
water(s)towhichitisexposedandrelatedserviceconditions.
AuthoritiesHavingJurisdictionshouldbeconsultedbeforeinstallation.
FACTORSNOTINVESTIGATED
http://database.ul.com/cgibin/XYV/template/LISEXT/1FRAME/showpage.html?&name=VIZY.GuideInfo&ccnshorttitle=Metallic+Sprinkler+Pipe&objid=1074306 1/2
1/9/2016 VIZY.GuideInfoMetallicSprinklerPipe
Pipematerialshavenotbeeninvestigatedforpotabilityunlessindicatedintheindividualcertifications.
Coatings,platingsorothersurfacetreatmentsontheinteriororexteriorofthepipehavenotbeeninvestigatedfortheabilitytoprotectthe
pipefromcorrosion,potability,ortheeffectsofthecoatings,platingsorothersurfacetreatmentsoncomponentsofthewaterdistribution
system.
PRODUCTIDENTITY
Thefollowingproductidentityappearsontheproduct:
MetallicSprinklerPipe
Otherproductidentitiesmaybeusedasshownintheindividualcertifications.
RELATEDSERVICES
MetallicsprinklerpipecertifiedtoNSF/ANSI61,"DrinkingWaterSystemComponentsHealthEffects,"havebeeninvestigatedforcontact
withdrinking(potable)waterandarecoveredunderDrinkingWaterSystemComponents(FDNP).
MetallicsprinklerpipecertifiedtoNSF/ANSI372,"DrinkingWaterSystemComponentsLeadContent,"havebeeninvestigatedforlead(Pb)
contentandarecoveredunderLeadContentVerificationofProductsinContactwithPotableWater(QNVB).
ADDITIONALINFORMATION
Foradditionalinformation,seeFireProtectionEquipment(AAFP).
REQUIREMENTS
ThebasicstandardusedtoinvestigateproductsinthiscategoryisUL852,"MetallicSprinklerPipeforFireProtectionService."
ULMARK
TheCertificationMarkofULontheproductistheonlymethodprovidedbyULtoidentifyproductsmanufacturedunderitsCertificationand
FollowUpService.TheCertificationMarkfortheseproductsincludestheULsymbol,thewords"CERTIFIED"and"SAFETY,"thegeographic
identifier(s),andafilenumber.
AlternateULMark
TheListingMarkofULontheproductistheonlymethodprovidedbyULtoidentifyproductsmanufacturedunderitsListingandFollowUp
Service.TheListingMarkfortheseproductsincludestheULsymbol(asillustratedintheIntroductionofthisDirectory)togetherwiththeword
"LISTED,"acontrolnumber,andtheproductname"+SprinklerPipe."
+Denotes"Metallic"ortheappropriatemetallicmaterialasindicatedintheindividualListings.
*************************
UL,inperformingitsfunctionsinaccordancewithitsobjectives,doesnotassumeorundertaketodischargeanyresponsibilityofthe
manufactureroranyotherparty.ULshallnotincuranyobligationorliabilityforanyloss,expenseordamages,includingincidentalor
consequentialdamages,arisingoutoforinconnectionwiththeuse,interpretationof,orrelianceuponthisGuideInformation.
LastUpdatedon20130815
2016ULLLC
Theappearanceofacompany'snameorproductinthisdatabasedoesnotinitselfassurethatproductssoidentifiedhavebeenmanufactured
underUL'sFollowUpService.OnlythoseproductsbearingtheULMarkshouldbeconsideredtobeCertifiedandcoveredunderUL'sFollowUp
Service.AlwayslookfortheMarkontheproduct.
ULpermitsthereproductionofthematerialcontainedintheOnlineCertificationDirectorysubjecttothefollowingconditions:1.TheGuide
Information,Assemblies,Constructions,Designs,Systems,and/orCertifications(files)mustbepresentedintheirentiretyandinanon
misleadingmanner,withoutanymanipulationofthedata(ordrawings).2.Thestatement"ReprintedfromtheOnlineCertificationsDirectory
withpermissionfromUL"mustappearadjacenttotheextractedmaterial.Inaddition,thereprintedmaterialmustincludeacopyrightnoticein
thefollowingformat:"2016ULLLC".
http://database.ul.com/cgibin/XYV/template/LISEXT/1FRAME/showpage.html?&name=VIZY.GuideInfo&ccnshorttitle=Metallic+Sprinkler+Pipe&objid=1074306 2/2