You are on page 1of 4

Data Sheet

3080, 3082
Compact Service-Aware Industrial Ethernet Switch

Compact switch with 8x10/100TX + 2x100/1000 SFP ports


Advanced Ethernet switching and IP routing feature-set
Secure Industrial Application-aware firewall per port
Integrated VPN agent for inter-site connectivity or remote user access
Ethernet Solution
Optional RS-232 port with protocol gateway functionality
Optional cellular 2G/3G modem with 2 SIM cards for operator redundancy
Fit to harsh industrial environment
Combined with the 3030/3070 modular systems for a large-scale network
Supported by RADiFlow industrial service management tool (iSIM)
3080, 3082
Compact Service-aware Industrial Ethernet Switch

The RADiFlow Service-aware Industrial FACTORY INFRASTRUCTURE UTILITY INFRASTRUCTURE


Ethernet switches, combine a ruggedized Optimization of the manufacturing processes In the modern era national utility infrastructure
Ethernet platform with a unique application- require real-time communication between the operators need to connect their remote
aware processing engine. enterprise network and the production-floor. distributed sites to the SCADA control center.
As an Industrial Ethernet switch the RADiFlow For a large scale plant some of the automation Such communication between distributed
switches provide a strong packet processing devices are located in remote sites that utility sites must be served using highly
feature-set with a special emphasis on the fit require a compact switch combined with strict integrated switches for cost and space savings
to the mission-critical industrial environment: security enforcement measures. while ensuring a reliable and secure services.
Fit to the harsh environment conditions With the RADiFlow compact switches you can With the RADiFlow switches you can
Robust system design ensuring high implement a simple network solution that implement a compact integrated
reliability of the product addresses all the requirements: communication center in each site providing:
Support for network resiliency schemes to Fit to the industrial environmental Fit to the out-door environmental
ensure end-to-end high-availability conditions conditions
Wide portfolio ranging from compact Compact Ethernet switch with 8x10/100TX
In addition the RADiFlow switches have Ethernet switches to modular multi-service
unique service-aware capabilities that enable ports and 2x100/1000 SFP ports
switches supporting Ethernet-based and Optional serial port for connection of
an integrated handling of application-level Serial-based end-devices over a unified
requirements such as implementation of legacy user equipment
Ethernet network Optional cellular modem integrated in the
security measures. App-aware firewall to verify proper access switch with 2 SIM cards and usage of
Such an integrated solution results in a simple to each industrial end-device encrypted tunnels over the public network
network architecture with an optimized fit to Intuitive Operation and Maintenance of the Distributed firewalls throughout the
the application requirements. network using the iSIM tool network to isolate the various logical
functions and to control the traffic that
flows between the sites
VPN agent for secure connection from
remote maintenance centers

Figure 1. Simple yet secure connection for Smart-Grid secondary sub-stations using the 3080 switch
Data Sheet

RUGGEDIZED COMPACT SYSTEM APPLICATION-AWARE SECURITY MULTI-SERVICE INTERFACES


The 3080 switch is a compact switch with The RADiFlow switch contain an integrated The 308x switches also support a RS-232
8x10/100TX ports and 2x10/100/1000 SFP firewall on each port, providing a network- serial interface with serial data tunneling or
ports thus suitable for aggregation of remote based distributed security solution equivalent service gateway to IP-based industrial
industrial sites with 100M or 1GE uplink. to the use of personal firewalls on all the protocols.
The switch is designed for installation in harsh industrial systems in the factory.
industrial applications including DIN-rail The firewall implemented in the switch is The 308x can offer an integrated cellular
mount, IP30 protection level, -40 to +75 "application-aware", meaning that it inspects 2G/3G modem for easy connectivity of remote
operating temperature range with no fans, the contents of the data packets according to sites. 2 SIM cards are supported by the
ATEX class 2 hazardous environment, EMI the rules of the industrial protocol used. This modem to choose between 2 cellular
immunity according to IEC61850-3 and firewall is operated according to user-defined operators based on the dynamic monitoring of
according to EN50121-4, etc. access-rules for each end-device up to the their network quality.
level of the industrial protocol command
NETWORK RESILIENCY parameters. SERVICE MANAGEMENT TOOL
The RADiFlow switches support Ethernet rings The switch also contains a VPN gateway with The RADiFlow switches are best utilized when
according to the ITU-T G.8032 standard. This 2 operation modes: Inter-site connectivity operating their network-wide features using
standard-based ring protection is the preferred using IPSec tunnels and remote user access the iSIM central management tool without
method of data-path resiliency ensuring fast using SSH. requiring in-depth IT know-how.
failure detection and switchover regardless of For the inter-site VPN the switch uses The iSIM presents the network topology in a
the scale of the network. GRE tunnels over an IPSec encrypted link. graphical map view enabling the provisioning
Traditional resiliency protocols such as RSTP The usage of IPSec encryption ensures the of service connections between the industrial
and MSTP are also supported for tree-based privacy of the link while the usage of GRE end-devices with detailed security rules. The
networks. tunneling enables the transparent connection user configures application-aware security
In order to use a unified Ethernet network of the Ethernet networks sites. rules for each pair of end-devices starting from
across the factory but still isolate the traffic For remote access the switch uses a SSH- the protocol level and up to the specific
between different groups of devices, service encrypted tunnel, with user authentication and parameters of the industrial protocols and the
groups are created using Ethernet VLANs. specific access authorizations. Over the SSH iSIM translates these rules to specific
Such network setup enables the enforcement tunnel any protocol can be redirected in the configuration for each switch.
of quality-of-service and security measures on remote host and the gateway will implement a The iSIM also provides several tools for easy
each service group regardless of the scale of proxy to securely transfer this protocol to the operation and monitoring of the network
the network. target device. including: Network alarms log, Security
violations log and link utilization statistics.

Figure 2. Distributed firewall configuration


3080, 3082
Compact Service-aware Industrial Ethernet Switch

Specifications are subject to change without prior notice. 2011 RADiFlow Ltd.
Specifications
NETWORKING SECURITY MANAGEMENT TOOLS

ADVANCED LAYER 2 FEATURE-SET ACCESS CONTROL NETWORK MANAGEMENT


ITU-T G.8032 Ethernet ring (<50mS recovery) Enable/Disable port Network elements auto-discovery
IEEE 802.1s MSTP, 802.1w RSTP Port access filter per MAC / IP addresses End-to-End service groups provisioning
IEEE 802.3ad LAG with LACP Security rules planning per service group
SERVICE VALIDATION
IEEE 802.1q VLAN tagging Network performance & diagnostics tools
Egress filtering per VLAN
IEEE 802.1p per port queues
Application-aware firewall on each port LOCAL OPERATION
analyzing industrial protocols
LAYER 3 FEATURE-SET RS-232 console with command line interface
L3 Switching INDUSTRIAL VPN AGENT Failsafe output relay reporting critical alarm
Static routing, OSPF Routing Inter-site connection using GRE over IPSec
DSCP to 802.1p QoS mapping Remote access using SSH tunnel
Ordering
Session proxy hiding the local network 308x P/Ns - BS-C<F><P>8<N><T>
MULTICAST F Functionality level
On-line session security checks B Basic, No security module
L2 Multicast with guaranteed QoS
AES or 3DES encryption S Security module included
IGMP Snooping for traffic optimization P - Power-supply type
Traffic activity recording for Trail audit 1 24V DC
BRIDGING SERIAL STREAMS 2 48V DC
Transparent tunneling serial streams N - Networking feature-set
PHYSICAL DESIGN 0 Wire-line ports only
Protocol Gateway - Serial to Ethernet 2 Integrated cellular modem
DIN rail mounting, optional wall mount
(Modbus, IEC101/104, DNP3.0) T Temperature range
Rugged enclosure - IP 30 rated, No fans S Standard 060C
SYSTEM PERFORMANCE E Extended -4075C
Operating temperature: -40 to 75C
32K MAC addresses LS-IP001E
Operating Humidity: 5%-95%
4K VLANs IP routing license
Basic system and optional security module
SFPs
INTERFACES Dimensions (HxWxD) 148x102x135[mm] Ethernet Optic MM/SM and Copper
8 x 10/100 TX ports DC 24V/48V power supply with 2 power inputs Contact us for more details

2 x 100/1000 SFP ports IEC 61850-3/IEEE1613 EMI iSIM tool See iSIM data-sheet

Optional RS-232 port EN50121-4 Vibration and Shock resistance


Optional 2G/3G cellular modem

4 Hanehoshet Street
Tel Aviv 69710, Israel
E-mail: info@radiflow.com