Troubleshooting
25 Pound Capacity
30 Pound Capacity
35 Pound Capacity
55 Pound Capacity
Starting Serial No. 0602004144
Refer to Page 7 for Model Numbers
1
SELEC
TEMP T
2
INSER
COIN T
3
PUSH
START
HIGH
TEMP
MED
STAR
T
25 C
TEMP
LOW
TEMP
NO
HEAT
CAUTION
Caution indicates a hazardous situation
that, if not avoided, may cause minor or
moderate personal injury or property
damage.
WARNING
Repairs that are made to your products by
unqualified persons can result in hazards
due to improper assembly or adjustments
subjecting you, or the inexperienced
person making such repairs, to the risk of
serious injury, electrical shock, or death.
W007
CAUTION
If you or an unqualified person perform
service on your product, you must assume
the responsibility for any personal injury or
property damage which may result. The
manufacturer will not be responsible for
any injury or property damage arising from
improper service and/or service
procedures.
W008
TMB2098N
1 Serial Plate
Customer Service
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized parts
distributor.
For technical assistance, call (920) 748-3121.
Wiring Diagram
The wiring diagram is located inside the contactor or
junction box.
The wiring diagram part number is located in the lower
portion of the electrical data on the serial plate.
T001CE3A
Tumbler Does
Not Start
Is motor Is the
Yes Test relay and Press and
relay START button
replace if hold
inoperative? not properly Yes
necessary. START button
activated
(Hybrid Timer for three
Models)? seconds.
No
No Is the
electrical power Yes Check power
off or circuit supply, or
breaker or fuse replace fuses.
Is blown?
drying timer in
Yes Turn drying
an off position
(Hybrid Timer timer on.
No
Models)?
Is there an
Check that No
incorrect Yes proper amount
amount of coins
of coins are
inserted into
inserted.
coin drop?
No
TMB2036S
Motor Does
Not Start
Is there
broken, loose, Yes Refer to wiring
or incorrect diagram.
wiring?
Is the No
electrical power Yes Check power
off or circuit supply, or replace
breaker fuse fuses. Is
blown? the fan or fan Yes Replace fan or
motor motor assembly.
binding?
No
No
Is the
loading door Close door, panel
switch or lint Yes or test switch and
panel switch not Is the
replace if Yes Replace cylinder,
closed or switch cylinder or
inoperative. bearing, rollers, or
inoperative? cylinder motor
motor assembly.
binding?
No No
Is the Refer to
door switch Yes Is the
Adjustments Yes
improperly transformer Test and replace
Section for door
adjusted? inoperative? if necessary.
switch adjustment.
No No
Is the
motor relay Yes Test relay and replace
Is the start Yes Press and hold
circuit not START button for inoperative? if inoperative.
complete? three seconds.
No
No
Is the
Yes Have motor tested airflow switch Yes Test switch,
Is the motor
and replace if inoperative replace or adjust
inoperative?
inoperative. (Hyrid Timer as required.
Models)?
No
TMB2037S
Refer to
Is voltage Yes Installation
correct? Manual for
electrical
requirements.
No
Is clothes Yes
load too Remove part of
large? load.
No
Is clothes Yes
cylinder Check cylinder
binding? for binding.
No
Check with
local power
Is wiring Yes company to
adequate? ensure that
wiring is
adequate.
No
Refer to
Yes Installation
Is make-up
Manual for
air adequate?
make-up air
requirements.
No
Clean lint
accumulation
Is there lint
Yes on and around
buildup around
the motors.
tumbler or poor
maintenance?
Is there
broken, loose Yes Refer to wiring
No or incorrect diagram.
wiring?
TMB1904S
Motor Runs
But Cylinder
Does Not Turn
No
TMB1905S
Motor Does
Not Stop
Is the door
switch or lint Yes Test switches
panel switch and replace if
not working inoperative.
properly?
No
No
No
No
TMB2038S
Burner Does
Not Ignite Is
stove limit Yes Test thermostat 2
thermostat 2 and replace if
inoperative? inoperative.
Is there Refer to
an improper or Yes Installation
Manual for No Open partially closed
inadequate exhaust
exhaust system gas shut-off valve, or
system?
requirements. correct low gas
pressure. Check
Is manifold pressure
No Yes and adjust to
there an
insufficient gas pressure specified on
supply? serial plate. If
Are there pressure cannot be
blown fuses or Yes obtained, have your
Check fuses or
tripped circuit breakers local gas company
circuit breaker.
in external electric No check main gas
supply line? pressure.
No Tumbler is equipped
for type of gas
Is
Are the specified on serial
drying Yes
orifices plate. If orifices are
selector in the Yes Reset switch on
incorrect? different from that
Cool Down microprocessor. specified on serial
portion of
plate, obtain and
cycle?
No install correct orifices.
No
Clean lint
Is compartment. Check
the cabinet Yes Test thermostat Is there Yes damper for lint
thermostat and replace if lint
accumulation. Check
inoperative? inoperative. buildup?
ductwork for lint
buildup.
No
No
Refer to Installation
Is Is there Manual to ensure
stove limit Yes Test thermostat 1 inadequate Yes that ductwork and
thermostat 1 and replace if ductwork and make-up air
inoperative? inoperative. make-up openings are sized
air? accurately.
No
No Continued on
next page
TMB2187S-a
No
No
Is the Yes
Is Clearance IEI control Replace IEI
there an should be inoperative? control.
Yes
improper igniter 0.110 - 0.140
to burner inch (2.79 - 3.55
clearance? mm). No
Is
No Yes
motor switch Replace motor.
inoperative?
Check valve
Are valve coils Yes
coils and
inoperative? replace if No
necessary.
Continued on
next page
No
TMB2187S-b
Continued from
previous page
Is there
an inoperative Yes Test and replace
microprocessor or as needed.
hybrid timer?
No
Is
wrong Check incoming
transformer Yes voltage and install
configuration correct
harness configuration
installed? harness.
No
Reset IEI control by
opening and closing
Is Instant loading door. (Non-
Electronic CE models only)
Yes
Ignition (IEI)
control in safety Reset IEI by
lockout? pressing reset
button on back of
unit. (CE models
only)
TMB2187S-c
Burner Ignites
and Goes Out
Repeatedly
Is
Yes
there excessive Refer to
igniter to burner Paragraph 43.
clearance?
Is there
Yes Check gas
insufficient
supply and
gas No
pressure.
pressure?
Refer to
Is Installation
No Yes
there inadequate Manual for
make-up air? make-up air
Is the requirements.
cabinet Yes Test thermostat
thermostat and replace if
inoperative? inoperative. No
No Is the
Yes Replace
thermistor
Refer to inoperative? thermistor.
Is the Installation
exhaust system Yes Manual for
improper or exhaust
inadequate? system No
requirements.
No
TMB1908S
Burner Does
Not Shut Off
Are there
impurities on gas Yes Replace gas
valve seat,
valve.
preventing valve
from closing?
No
No
TMB1909S
Clothes Do Not
Dry
Does
the burner ignite Yes Refer to
Is there and go out Paragraph 7.
enough heating Start cycle again
Yes repeatedly?
time allocated for with enough time to
the load? dry load.
No
No Is
the drying Set selector
Yes
selector for higher
improperly setting.
Is the burner not Yes Refer to
set?
igniting? Paragraph 6.
No
Is there
Yes Refer to Installation
No inadequate Manual for make-up
make-up air requirements.
Remove part of air?
Is load. Maximum
the clothes Yes load is 25 pound No
load too dry weight (cotton
large? load) for 25 pound
Is the
Tumbler, etc. Yes
exhaust duct to Clean duct to
the outside remove blockage.
No
blocked?
Is the
Refer to Installation No
exhaust system Yes Manual for exhaust
improper or
system
inadequate?
requirements.
Continued on
next page
No
TMB1910S-a
Continued from
previous page
No No
No
No
TMB1910S-b
Is the
No exhaust Adjust damper
Yes
damper so it turns
binding? freely.
Is gas Adjust gas pressure
Yes
pressure too high or as specified on
low? serial plate. No
Is the
No control heater
Yes
relay Replace control.
malfunctioning?
Is the Refer to Installation
Yes
make-up air Manual for make-up
inadequate? air requirements.
No
No Are
the safety covers
Yes
missing, allowing Replace covers.
Clean lint cool air to enter
compartment. Check tumbler?
Is there Yes damper for lint
lint buildup? accumulation. Check No
ductwork for lint
buildup.
Is the
No lint screen
Yes Replace lint
clogged with
screen.
Remove obstruction fabric
or lint build up from softener?
Is the exhaust ductwork.
exhaust system Yes No
Refer to Installation
restricted or Manual for exhaust
inadequate? system
requirements. Are there
Yes Repair/replace
holes in cabinets
cabinet
due to foreign
components.
No objects?
TMB1911S
Is
Disassemble the airflow
Is there lint/dirt in Yes
burner and switch not Yes Replace airflow
burner tube?
blow out the dirt. functioning switch.
properly?
No No
Check serial
Is the gas plate on back of Is there
Yes Refer to Installation
pressure too high tumbler for inadequate Yes
Manual for make-up
or low? correct gas make-up
air requirements.
pressure. air?
No Tumbler is equipped
No
for the type of gas
specified on serial
Does
plate. If orifices are
the tumbler have Yes
different from that
incorrect
specified on serial Is there lint buildup Yes
orifices? Clean off lint.
plate, obtain and around gas valve
install correct spud?
orifices.
No
Is the
exhaust duct Yes Disassemble
restricted or and clean
blocked? exhaust system.
No
TMB1912S
Loading Door
Opens During
Operation
No
Is clothes Yes
load too Remove part of load
large? and restart tumbler.
No
Is loading Refer to
door strike Yes Adjustments
adjusted Section for strike
incorrectly? adjustment.
TMB1913S
Cylinder
Continues To
Spin With Door
Open
TMB1914S
NOTE: All tumbler panels must be in place and on the machine for
proper operation.
14. Coin Does Not Fall into Coin Vault or Coin Drop Sensor Does Not Register
that Coin Has Been Entered
Incorrect electrical
Is proper
connection may
electrical
No prevent coins from
power
registering in coin drop.
supplied to
Refer to wiring
coin drop?
diagram.
TMB1915S
IMPORTANT: Never use oil to correct coin drop problem. Oil residue will prevent coins from rolling
properly.
IMPORTANT: Do not bend or damage mechanical parts within coin drop.
15. Loading Door Switch c. If switch actuator does not depress the switch
The door switch should be adjusted so the plunger enough to operate the switch, bend
cylinder stops when door is opened 2 inches (51 switch actuator OUTWARD and repeat steps
mm), plus or minus 1/4 inch (6 mm). The switch a and b..
is normally open and is closed when the door is
closed. If adjustment is needed, proceed as 16. Loading Door Strike
follows: Refer to Figure 1. Refer to Figure 1.
a. Close door and start tumbler. Slowly open The door strike must be adjusted so that sufficient
loading door. Cylinder and heat system should tension holds loading door closed against the
shut off when door is open 2 inches (51 mm), force of a load tumbling against it. The door is
plus or minus 1/4 inch (6 mm). properly adjusted when 8-15 lbs. (3.60-6.75 kg)
b. Slowly close loading door. When door is 2 of pull is required to open door.
inches or less from being fully closed, the
switch actuator on the door should contact the If adjustment is needed, follow these steps:
switch plunger and depress it enough to close a. Open loading door.
the switch with an audible click.
b. Loosen jamnut.
c. Turn door strike screw in or out as required.
d. Retighten jamnut.
Loading
Door
Switch
Actuator Jamnut
Door Strike
Screw T280SE3C
Figure 1
NO
YES
YES
NO
NO YES
(7)
NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?
YES YES
(2)
Correct wiring
between control and
NO Correct wiring secondary fuse.
Is there voltage at input between primary
of primary fuses? fuse and power
supply.
YES
(3)
Is there voltage at NO
Replace primary
output side of the
fuse(s).
primary fuses?
YES
(4)
NO Correct wiring
Is there voltage across
between primary
terminals 1 & 2 of
fuse and
transformer primary?
transformer.
YES
(5)
YES
TMB1979S
SERVICE
CONNECTION 2
L2
BLK
PRIMARY
FUSE
AGC-2A
LT. BLU
250V
BLK
1 2
5 1
120V
025 & 030 MODELS 035 & 055 MODELS
THERMISTOR THERMISTOR
4 WHT WHT WHT WHT
24V 24V WHT/BLU
3.5A 1.5A WHT
RED BLK BLK
2 3 1 4
H4 H4 10 9 8 7 6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
MDC CONTROL
H1-1
H1-3
RED
GRN/YEL
Micro Display Control (MDC) Troubleshooting
RED
6 WHT VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
SECONDARY 24Vac - WIRE JUMPER POWER HEAT RELAY
SECONDARY 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
FUSE 240Vac - 13.6K ohm 10 watt
FUSE
MDL-3.5A
1.25 T
DOOR SENSING CIRCUIT ALLOWS
24Vac Ret
250V
24VAC
250V CONTROL TO TURN ON MOTOR H2-6
RED/BLK
RELAY ONLY WHEN DOOR IS Door Sense Ret
7 CLOSED & SWITCH IS PRESSED
RED
H2-2
RED
H2-3
WHT
MOTOR RELAY
LINT N.C.
FS-1
DOOR ORG/BRN
RED/WHT
PANEL
SWITCH COM
SWITCH
Control Has No Display
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25
24Vac
Vmax=28Vdc
24Vac Ret
Imax=5ma
WHT/VLT
CABINET
LIMIT
SEE VEND THERMOSTAT
APPLICATION DETAIL
TMB2213S
70380601
Micro Display Control (MDC) Troubleshooting
NO YES
(7)
NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?
YES YES
(2) (8)
YES YES
(3) (9)
YES YES
(4) (10)
YES YES
(5) (11)
YES YES
Correct wiring
between H2-1 of
electronic control
and COM of lint
panel switch.
TMB2039S
SERVICE
CONNECTION 2 5
L2
3
4
BLK
PRIMARY
FUSE
AGC-2A
LT. BLU
250V
BLK
1 2
1
120V
025 & 030 MODELS 035 & 055 MODELS THERMISTOR
THERMISTOR
WHT WHT
24V 24V WHT/BLU WHT WHT
WHT
3.5A 1.5A BLK
RED BLK
2 3 1 4
H4 H4 10 9 8 7 6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
MDC CONTROL
H1-1
H1-3
6
RED
GRN/YEL
RED
WHT VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
Micro Display Control (MDC) Troubleshooting
24Vac Ret
250V
24VAC
250V CONTROL TO TURN ON MOTOR H2-6
RED/BLK
7 RELAY ONLY WHEN DOOR IS Door Sense Ret
CLOSED & SWITCH IS PRESSED
RED
H2-2
RED
H2-3
9 10 WHT
11
8 RED/BLU H2-1 H2-4
RED/BLK BRN/RED
MOTOR RELAY
LINT N.C.
FS-1
DOOR ORG/BRN
RED/WHT
PANEL
Door Open Indicator
SWITCH COM
SWITCH
FS-2 START PULSE INPUT N.O.
RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW
N.O. COM N.O. COM Iin= 3-30ma SWITCH
HEAT RELAY TIME 20msec MIN.
H11L1
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25
24Vac
Vmax=28Vdc
24Vac Ret
Imax=5ma
WHT/VLT
CABINET
LIMIT
SEE VEND THERMOSTAT
APPLICATION DETAIL
TMB2214S
70380601
Micro Display Control (MDC) Troubleshooting
NO Correct wiring
Is there voltage across
YES between fan motor
terminals 1 & 4 of
and motor control
(2) the fan motor?
relay.
Is there voltage NO
across H2-4 and H2-6 Replace
YES
on the electronic control? control.
NO
Does the fan motor
YES Replace fan motor.
run?
(3)
Is there voltage NO
across the coil of Correct wiring to coil
YES
the motor control of motor relay .
relay?
Is there voltage at NO
Replace motor
terminal 8 of motor NO
control relay.
control relay?
(7)
YES
Is there votlage across Replace motor
L1 & T1 and L2 & T2? control relay.
YES
NO
TMB1982S
NO Correct wiring
Is there voltage across
between cylinder
terminals 1 & 4 of
motor and motor
cylinder motor?
control relay.
YES
NO
Does the cylinder Replace cylinder
motor run? motor.
YES
Motors are
operational.
TMB1982S
TMB1982S
TB1-N
120V
SERVICE
TB1-L2
208-240V
SERVICE
BLK/RED
BLK
5
LT. BLU
5 6 BLK/RED
8
M M
1
025 & 030 MODELS 035 & 055 MODELS
THERMISTOR THERMISTOR 8
FAN 9
CYLINDER
WHT WHT WHT WHT
MOTOR MOTOR
WHT/BLU
5
WHT 3
RED BLK BLK
GRY/BLK
BLU/BLK
RUN RUN
1 1
H4 10 9 8 7 6 5 4 3 2 1 H4 10 9 8 7 6 5 4 3 2 1
MDC CONTROL
H1-1
H1-3
GRN/YEL AUX AUX
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
MAIN 2 4 MAIN 2 4
24Vac - WIRE JUMPER POWER HEAT RELAY THERM THERM
120Vac - 6.8K ohm 5 watt SUPPLY PROT. PROT.
CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
24Vac Ret
24VAC
CONTROL TO TURN ON MOTOR H2-6
WHT
RED/BLK
RELAY ONLY WHEN DOOR IS Door Sense Ret
CLOSED & SWITCH IS PRESSED
H2-2 2 3
H2-3
WHT
B A 6 9
H2-4
RED/BLK BRN/RED M WHT
H2-1
MOTOR RELAY M
N.C.
FS-1 ORG/
ORG/BRN ORG BRN WHT/
WHT BRN
COM 7 4 3 5
FS-2 START PULSE INPUT N.O.
RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
Iin= 3-30ma SWITCH CENTRIFUGAL
TIME 20msec MIN. SWITCH
HEAT RELAY
BRN/WHT
H11L1
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25
24Vac
Vmax=28Vdc
24Vac Ret
Imax=5ma
Motor Will Not Start/Run (Sheet 1 of 2)
IGN
WHT/VLT
COIN DROPS 100 OHM
WHT
1/4 watt
H5 H6 H3
H1-2
H1-4
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1
TH GND
VLT VLT/WHT 3
TMB2215S
Micro Display Control (MDC) Troubleshooting
37
38
TB1-L1
TB1-L1
TB1-L2
TB1-L2
TB1-L3
TB1-L3
L2 L3
BLK
WHT
BLK/
BLK
BLK/RED
PRIMARY 10 12
BLK/WHT
HC2 HC1
FUSES
AGC-2A L1 L2 L3
T2 T3 250V
M M M 13
BLK
WHT
BLK/
H3 1 2
11
T1 T2 T3
SEE
TRANSFORMER 1
CONFIGURATION
JUMPER
1 2 3 4 5 6 025 & 030 MODELS 035 & 055 MODELS 5
3
THERMISTOR THERMISTOR
GRY/BLK
BLU/BLK
H5 RUN RUN
LT. BLU
LT. BLU
1 1
WHT/BLU WHT WHT WHT WHT
WHT
RED BLK BLK AUX AUX
24V 24V
4.0A 1.5A MAIN 2 4 MAIN 2 4
H4 H4 THERM THERM
10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
MDC CONTROL PROT. PROT.
H1-1
2 3 1 4
H1-3
GRN/YEL
Micro Display Control (MDC) Troubleshooting
RED
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS MAIN 1 MAIN 1
RED
24Vac - WIRE JUMPER POWER HEAT RELAY
WHT 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
SECONDARY 2 FAN CYLINDER
DOOR SENSING CIRCUIT ALLOWS
24Vac Ret
FUSE
24VAC
SECONDARY CONTROL TO TURN ON MOTOR H2-6 MOTOR
MDL-3.5A WHT MOTOR
RED/BLK
FUSE RELAY ONLY WHEN DOOR IS Door Sense Ret
250V 1.25 T CLOSED & SWITCH IS PRESSED
H2-2
250V H2-3
WHT
RED
RED
3
RED/BLU H2-1 H2-4
RED/BLK BRN/RED M WHT 6 9
MOTOR RELAY M
LINT N.C.
FS-1 ORG/
DOOR ORG/BRN ORG BRN WHT/
WHT BRN
RED/WHT
PANEL 3 5
SWITCH COM 14 13
SWITCH
FS-2 START PULSE INPUT N.O.
RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
N.O. COM N.O. COM Iin= 3-30ma SWITCH CENTRIFUGAL
TIME 20msec MIN. SWITCH
HEAT RELAY
BRN/WHT
H11L1
WHT
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25
24Vac
Vmax=28Vdc
24Vac Ret
Imax=5ma
WHT/VLT
H1-2
H1-4
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1
Motor Will Not Start (Sheet 2 of 2)
VLT VLT/WHT
70380601
Micro Display Control (MDC) Troubleshooting
Correct wiring
NO Correct wiring Is there voltage at NO between terminal 3
Is there voltage at terminal 3 of fan of fan motor
between FS-2 and
FS-2 of MDC control? motor centrifugal centrifugal switch
COM of lint drawer.
switch? and terminal 4 of
motor control relay.
YES YES
Replace Replace MDC
thermistor. control.
(2) (8)
Is the
YES
thermistor
operational?
YES NO
(3) (9)
YES YES
(4) (10)
NO NO
(5) (11)
Correct wiring
Is there voltage at NO between terminal 7 NO Correct wiring
on motor control Is there voltage to the
terminal 7 of motor input side of the stove between stove limit 1
control relay? relay and N.C. and cabinet limit.
terminal on airflow limit?
switch.
YES YES
(6)
NO
TMB1985S
(12)
NO YES
(13)
YES YES
(14)
NO
NO
(15)
YES
Note: Make sure unit is
not in a lock out
(16) condition.
Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?
YES
(17)
NO Correct wiring
Is there voltage across
between gas valve
the coils of the gas
and ICM board.
valve?
YES
TMB1985S
TMB2217S
16
17
9
7
8
6
14
5
15
4
10
3
1
13
12
11
2
(1) (7)
Correct wiring
NO Is there voltage on NO between terminal 3
Correct wiring
Is there voltage on terminal 3 of fan of fan motor
between FS-2 and
FS-2 of MDC control? motor centrifugal switch? centrifugal switch
COM of lint panel.
and terminal 4 of
motor control relay.
YES
Replace MDC YES
Replace
control.
thermistor.
(2) (8)
Is the YES
thermistor
YES operational?
NO
(3) (9)
YES YES
(4) (10)
NO NO
(5) (11)
Correct wiring
NO between terminal 7 NO
Is there voltage on Is there voltage to the Correct wiring
on motor control
terminal 7 of motor input side of the stove between stove limit
relay and N.C.
control relay? limit? and cabinet limit.
terminal on airflow
switch.
YES
YES
(6)
NO TMB2040S
(12)
NO
(13)
NO Correct wiring
Is there voltage across between steam
the coil of the steam valve? valve and stove
Replace fan motor. limit.
YES
No
Correct wiring Does the steam valve Replace or rebuild
between cabinet open allowing steam to flow? steam valve.
limit and terminal 5
of fan motor
centrifugal switch.
Unit operational.
Replace cabinet
limit.
Correct wiring
between stove limit
and cabinet limit.
TMB2040S
H4 10 9 8 7 6 5 4 3 2 1 H4 10 9 8 7 6 5 4 3 2 1
MDC CONTROL
H1-1
H1-3
GRN/YEL
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
24Vac - WIRE JUMPER POWER HEAT RELAY
120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
7
DOOR SENSING CIRCUIT ALLOWS
24Vac Ret
24VAC
CONTROL TO TURN ON MOTOR H2-6
WHT
RED/BLK
RELAY ONLY WHEN DOOR IS Door Sense Ret
CLOSED & SWITCH IS PRESSED
H2-2
H2-3
2 WHT 5
Micro Display Control (MDC) Troubleshooting
4 B A
6 8
H2-1 H2-4
RED/BLK 3 BRN/RED M WHT
MOTOR RELAY M
N.C.
FS-1 ORG/
ORG/BRN ORG BRN WHT/
WHT BRN
COM 7 4 3 5
FS-2 START PULSE INPUT N.O.
RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
Iin= 3-30ma SWITCH CENTRIFUGAL
TIME 20msec MIN. SWITCH
HEAT RELAY
H11L1 BRN/WHT
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25
13
24Vac
Unit Will Not Heat Steam
Vmax=28Vdc
24Vac Ret
Imax=5ma 10 12
WHT/VLT
H1-2
H1-4
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1 VALVE
9
11
TMB2218S
70380601
Micro Display Control (MDC) Troubleshooting
(1)
(7)
Correct wiring
NO Correct wiring Is there voltage at NO between terminal 3
Is there voltage at between FS-2 and terminal 3 of fan of fan motor
FS-2 of MDC control? COM of lint panel motor centrifugal centrifugal switch
switch. switch? and terminal 13 of
motor control relay.
YES YES
Replace Replace MDC
thermistor. control.
(2) (8)
Is the YES
thermistor
YES operational?
NO
(3) (9)
YES YES
(4) (10)
NO NO
(5) (11)
Correct wiring
NO between terminal 7 NO
Is there voltage at Is there voltage to the Correct wiring
on motor control
terminal 14 of motor input side of the stove between stove limit
relay and N.C.
control relay? limit? and cabinet limit.
terminal on airflow
switch.
YES YES
(6)
TMB2041S
NO
YES
Is there voltage across Replace the stove
the stove limit? limit.
NO
(13)
NO Correct wiring
Is there voltage across
between heater
the coil(s) of the heater
contactor and stove
contactor(s)?
limit.
YES
(14)
YES
(15)
YES
(16)(17)(18)
NO Check for
Is there voltage across
proper operation of
T1 & T2, T2 & T3 and
contactors, replace
T3 & T1?
them if necessary.
Unit is operational
YES
YES
TMB2041S
SERVICE TB1-L2
L2
CONNECTION
TB1-L3
L3
L3 L1 L1 L2 L2 L3
BLK
WHT
BLK/
HC2 HC1 HC2 HC1 HC2 HC1 PRIMARY
FUSES
AGC-2A
T3 T1 T1 T2 T2 T3 250V
BLK
WHT
BLK/
H1 H2 H3 1 2
SEE
TRANSFORMER 1
CONFIGURATION
JUMPER
16
1 2 3 4 5 6 025 & 030 MODELS 035 & 055 MODELS
THERMISTOR THERMISTOR
H6 H4 H5
WHT/BLU WHT WHT WHT WHT
WHT
RED BLK BLK
H1-1
2 3 1 4
H1-3
17 18 GRN/YEL
RED
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
15 H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
RED
24Vac - WIRE JUMPER POWER HEAT RELAY
WHT 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
SECONDARY 7
DOOR SENSING CIRCUIT ALLOWS
24Vac Ret
FUSE
24VAC
SECONDARY CONTROL TO TURN ON MOTOR H2-6
MDL-3.5A WHT
RED/BLK
FUSE RELAY ONLY WHEN DOOR IS Door Sense Ret
250V 1.25 T CLOSED & SWITCH IS PRESSED
H2-2
250V H2-3
2 WHT 5
RED
RED
4 6 8
RED/BLU H2-1 H2-4
RED/BLK 3 BRN/RED M WHT
MOTOR RELAY M
LINT N.C.
FS-1 ORG/
DOOR ORG/BRN ORG BRN WHT/
WHT BRN
RED/WHT
PANEL 3 5
SWITCH COM 14 13
SWITCH
FS-2 START PULSE INPUT N.O.
RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
N.O. COM N.O. COM Iin= 3-30ma SWITCH CENTRIFUGAL
Unit Will Not Heat Electric
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN 13
MACHINE RUNNING
4N25
24Vac
Vmax=28Vdc
24Vac Ret
Imax=5ma 10 12
WHT/VLT
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1
VLT VLT/WHT
9
11
TMB2219S
Micro Display Control (MDC) Troubleshooting
47
Micro Display Control (MDC) Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TMB2241S
TMB2221S
TMB2027S
TMB2026S
TMB2222S
TMB2223S
TMB2027S
TMB2026S
TMB2220S
Electric Models
Control Circuit Schematic
TMB2224S
Electric Models
Control Circuit Connection
TMB2030S
Electric Models
Control Box Connection
TMB2031S
Electric Models
Control Box Schematic
NO
"E:OF"
- IR communication disabled by
manual programming.
- Is the IR window on the control
covered or blocked.
- if needed, change control
board.
TMB1991S
NO
YES
YES
NO
NO YES
(7)
NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?
YES YES
(2)
Correct wiring
between control and
NO Correct wiring secondary fuse.
Is there voltage at input between primary
of primary fuses? fuse and power
supply.
YES
(3)
Is there voltage at NO
Replace primary
output side of the
fuse(s).
primary fuses?
YES
(4)
NO Correct wiring
Is there voltage across
between primary
terminals 1 & 2 of
fuse and
transformer primary?
transformer.
YES
(5)
YES
TMB1993S
TMB2225S
1
5
3
2
7
6
4
NO YES
(7)
NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?
YES YES
(2) (8)
YES YES
(3) (9)
YES YES
(4) (10)
YES YES
(5) (11)
YES YES
Correct wiring
between H2-1 of
electronic control
and COM of lint
panel switch.
TMB2042S
TMB2226S
1
11
4
5
3
10
9
2
8
6
NO Correct wiring
Is there voltage across
YES between fan motor
terminals 1 & 4 of
and motor control
(2) the fan motor?
relay.
Is there voltage NO
across H2-4 and H2-6 Replace
YES
on the electronic control? control.
NO
Does the fan motor
YES Replace fan motor.
run?
(3)
Is there voltage NO
across the coil of Correct wiring to coil
YES
the motor control of motor relay .
relay?
Is there voltage at NO
Replace motor
terminal 8 of motor NO
control relay.
control relay?
(7)
YES
Is there votlage across Replace motor
L1 & T1 and L2 & T2? control relay.
YES
NO
NO Correct wiring
Is there voltage across
between cylinder
terminals 1 & 4 of
motor and motor
cylinder motor?
control relay.
YES
NO
Does the cylinder Replace cylinder
motor run? motor.
YES
Motors are
operational.
TMB2043S
TMB2043S
TMB2227S
9
7
6
5
4
3
2
1
TMB2228S
9
12
13
6
10
11
3
2
1
(1) (7)
Correct wiring
NO Is there voltage at NO between terminal 3
Correct wiring
Is there voltage at terminal 3 of fan of fan motor
between FS-2 and
FS-2 of the control? motor centrifugal centrifugal switch
COM of lint panel.
switch? and terminal 4 of
motor control relay.
YES YES
Replace Replace the
thermistor. control.
(2) (8)
Is the YES
thermistor
YES operational? NO
(3) (9)
YES YES
(4) (10)
NO NO
(5) (11)
Correct wiring
NO between terminal 7 NO
Is there voltage at Is there voltage to Correct wiring
on motor control
terminal 7 of motor the input side of between stove limit 1
relay and N.O.
control relay? stove limit 1? and cabinet limit.
terminal on airflow
switch.
YES YES
(6)
NO
(12)
NO YES
(13)
NO Correct wiring to
Is there voltage to the NO Replace high
input side of
input side of the Does the igniter spark? voltage ignition
stove limit 2 and
stove limit 2? cable or igniter.
stove limit 1.
YES YES
(14)
Is there NO YES
Replace
voltage across stove limit 2. Is there a flame? Unit operational.
stove limit 2?
YES NO
(15)
YES
Note: Make sure unit is
not in a lock out
(16) condition.
Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?
YES
(17)
YES
TMB2231S
TMB2231S
TMB2229S
17
16
8
7
15
9
6
14
13
5
10
4
12
3
2
or
or
11
1
(1) (7)
Correct wiring
NO Is there voltage on NO between terminal 3
Correct wiring
Is there voltage on terminal 3 of fan of fan motor
between FS-2 and
FS-2 of electronic control? motor centrifugal switch? centrifugal switch
COM of lint panel.
and terminal 4 of
motor control relay.
YES YES
Replace electronic
Replace (8)
control.
thermistor.
(2)
(4) YES
Is there voltage across Replace cabinet
cabinet limit? limit.
(11)
NO
NO Correct wiring
(5) Is there voltage across between steam
the coil of the steam valve? valve and stove
Correct wiring limit.
NO between terminal 7
Is there voltage on
on motor control
terminal 7 of motor
relay and N.C.
control relay? YES
terminal on airflow
switch.
YES
No
Does the steam valve Replace steam
open allowing steam to flow? valve.
(6)
Unit operational.
NO TMB2044S
TMB2230S
11
8
7
6
5
4
3
10
2
9
1
NO
YES
YES
NO
Is there voltage NO Connect supply Check H6-1 (+) and NO Replace hybrid
supplied to the unit? voltage and run unit. H6-2 (-) for +5 VDC. control assembly.
YES YES
Note : Reference voltage to
(1) supply neutral.
Replace display
Is there voltage to the Correct wiring assembly.
NO
input side of the between primary
primary fuse(s)? fuse and supply.
YES
(2)
YES
(3)
YES
(4)
YES
(5)
Correct wiring
Is there volt age across
NO between hybrid timer
terminals H1-3 &
and transformer
H1-1 on hybrid timer?
secondary.
YES
TMB2000S
TMB2106S
3
3
1
1
4
4
2
2
3
4
1
1
2
TMB2222S
6
5
NO YES
(7)
Is there voltage at NO
NO Replace secondary
Is there power supplied Plug unit in and run output side of
fuse.
to the unit? it. secondary fuse?
YES
YES
(8)
(2)
NO Connect wiring
Is there voltage
Correct wiring between COM and
NO at COM of
Is there voltage at input between primary output of secondary
door switch?
of primary fuses? fuse and power fuse.
supply.
YES
YES
(9)
(3)
With door closed, NO
is there voltage Replace
to NO of door door switch.
Is there voltage at NO
Replace primary switch?
output side of the
fuse(s).
primary fuses?
YES
YES (10)
(11)
YES
TMB2222S
10
1
9 8
7
6
11
TMB2108S
4
4
2
2
5
5
3
3
4
5
2
2
5
3
Yes
(7)
Yes
Yes (8)
Correct wiring
(4) Is between the
there voltage No secondary
Is
there voltage at COM of the fuse and COM
No Replace door switch? of the door
at the output
side of the transformer. switch.
transformer?
Yes
continued on
Yes next page
TMB2022S-a
continued from
previous page (13)
Is
the H6
(9) connection No Re-seat the
plugged in H6 connection
securely on the to the control.
Is
there voltage No control?
Replace the
at NO of the door switch.
door switch?
Yes
Yes
Is the
(10)
optic-coupler
Is harness Re-seat the
Correct wiring No
there voltage connected optic-coupler
No between the
at COM of the securely into the harness to the
door switch
lint drawer control control.
and lint drawer
switch? switch. harness?
Yes Yes
(11)
Is
there voltage No Replace the
at NO of the lint drawer Replace the No
lint drawer opto-coupler on Replace the
switch.
switch? the coin drop. control.
Yes
(12) Yes
Is Correct wiring
between the Unit is
there power at No
lint drawer operational.
H3-1 and H3-3
on the control? switch and H3
on the control.
Yes
TMB2022S-b
TMB2106S
3
3
1
1
4
4
2
2
3
4
1
1
4
2
TMB2232S
12
11
9
8
7
5
6
10
(6)
Yes Is
(2) there voltage No
at the output Replace the
Is side of the motor relay.
there voltage No motor relay?
Replace the
at H3-6 on the
control.
control?
Yes
(7)
Yes
Is
(3) there voltage Correct wiring
No between the
across the
Is Correct wiring motor and
lines of the
there voltage No between the motor relay.
motor?
at A1 on the control and
motor relay? the motor
relay A1.
Yes
Yes
Replace the
(4) motor.
Is
Correct wiring
there voltage
No between the
across A1 and
control and
A2 on the
the motor
motor relay?
relay A2.
Yes TMB2023S
TMB2232S
4
3
TMB2106S
7
7
7
7
6
5
7
6
7
7
5
5
7
7
7
7
5
5
6
6
6
5
6
7
NO Correct wiring
Is there voltage
YES between fan motor
across the lines of
and motor control
(2) the fan motor?
relay.
Is there voltage NO
across H3-4 and H3-6 Replace
YES
on the electronic control? control.
(7)
NO Correct wiring
Is there voltage at
YES between terminal 6
the input side of motor
of motor control
(3) control relay?
relay and supply.
Is there voltage NO
across the coil of Correct wiring to coil
the motor control of motor relay . YES
relay? (8)
Is there voltage at NO
YES Replace motor
the output side of motor
control relay.
control relay?
NO Correct wiring
Is there voltage
between cylinder
across the lines of
(4) motor and motor
cylinder motor?
control relay.
YES
(5) NO
Does the cylinder Replace cylinder
motor run? motor.
Is there voltage at NO
Replace motor
the output side of motor
control relay.
control relay?
YES
YES
Motors are
operational.
TMB2047S
TMB2232S
3
2
1
TMB2106S
7
7
7
7
6
5
7
6
7
7
5
5
7
7
7
7
5
5
6
6
6
7
7
9
8
9
4
5
4
5
6
NO Correct wiring
Is there voltage
YES between fan motor
across the lines of
and motor control
(2) the fan motor?
relay.
Is there voltage NO
across H4-3 and H4-4 Replace
YES
on the electronic control? control.
(7)
NO Correct wiring
Is there voltage at
YES between terminal 6
the input side of motor
of motor control
(3) control relay?
relay and supply.
Is there voltage NO
across the coil of Correct wiring to coil
YES
the motor control of motor relay .
relay? (8)
Is there voltage at NO
YES Replace motor
the output side of motor
control relay.
control relay?
NO Correct wiring
Is there voltage
between cylinder
across the lines of
(4) motor and motor
cylinder motor?
control relay.
NO
YES Does the cylinder Replace cylinder
(5) motor run? motor.
Is there voltage at NO
Replace motor
the output side of motor YES
control relay.
control relay?
Motors are
YES operational.
TMB2046S
TMB2233S
3
2
1
TMB2106S
7
7
7
7
6
5
7
6
7
7
5
5
7
7
7
7
5
5
6
6
6
7
7
8
8
9
9
4
5
4
5
6
Correct wiring
NO Correct wiring Is there voltage at NO between terminal 3
Is there voltage at terminal 3 of fan of fan motor
between FS-2 and
FS-2 of hybrid control? motor centrifugal centrifugal switch
NO of lint panel.
switch? and terminal 4 of
motor control relay.
YES YES
Replace Replace hybrid
thermistor. control.
(2) (8)
Is the
YES
thermistor
operational?
YES NO
(3) (9)
YES YES
(4) (10)
NO NO
(5) (11)
Correct wiring
Is there voltage at NO between terminal 7 NO Correct wiring
on motor control Is there voltage to the
terminal 13 of motor input side of the stove between stove limit 1
control relay? relay and NO and cabinet limit.
terminal on airflow limit 1?
switch.
YES YES
(6)
NO
(12)
NO YES
(13)
YES YES
(14)
NO
NO
(15)
YES
Note: Make sure unit is
not in a lock out
(16) condition.
Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?
YES
(17)
NO Correct wiring
Is there voltage across
between gas valve
the coils of the gas
and ICM board.
valve?
YES
TMB2048S
TMB2232S
17
16
15
7
8
5
14
4
3
12
2
10
1
11
13
(1) (7)
YES
YES NO
Replace hybrid
control.
(2) (8)
Correct wiring
Is there voltage at NO between terminal 13 NO Correct wiring
on motor control Is there voltage to the
terminal 13 of motor between stove limit 1
and H4-1 on input side of the stove
control relay? and cabinet limit.
hybrid control. limit 1?
YES YES
(3)
(9)
NO NO
(4) (10)
Correct wiring
Is there voltage at NO between terminal 3
Is there voltage to NO Correct wiring
terminal 3 of fan of fan motor
input side of between stove limit 1
motor centrifugal centrifugal switch
stove limit 2? and stove limit 2.
switch? and terminal 4 of
motor control relay.
YES YES
(5) (11)
NO
NO
(6)
(12)
Correct wiring
Is there voltage to the NO between cabinet Is there voltage to Correct wiring
NO
input side of the limit and terminal 5 terminal 2 of between terminal 2
cabinet limit? of fan motor the Ignition Control of ICM and stove
centrifugal switch. Module (ICM)? limit 2.
YES YES
TMB2006S
Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?
YES
(14)
NO Correct wiring
Is there voltage across
between gas valve
the coils of the gas
and ICM board.
valve?
YES
(15)
NO
Is the airflow switch Replace airflow
working properly? switch
YES
YES
NO Replace high
Does the igniter spark? voltage ignition
cable or igniter.
YES
YES
Is there a flame? Unit operational.
NO
TMB2006S
TMB2006S
100 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Hybrid Timer Control Troubleshooting
TMB2233S
14
13
12
5
7
4
11
3
2
9
1
6
8
10
15
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 101
Hybrid Timer Control Troubleshooting
(6)
(1)
Correct wiring
Is there Is the Is there voltage to the NO between cabinet
NO NO Replace
voltage at H4-1 thermistor input side of the limit and terminal 5
of hybrid control? operational? thermistor
cabinet limit? of fan motor
centrifugal switch.
YES
YES
YES
Replace hybrid
control.
(7)
(2)
YES
Is there voltage across Replace cabinet
Correct wiring cabinet limit? limit.
Is there voltage at NO between terminal 13
terminal 13 of motor on motor control
control relay? relay and hybrid
control.
NO
YES
(8)
(3)
YES
NO
(9)
(4)
YES
Correct wiring Is there voltage across Replace the stove
Is there voltage at between terminal 3 the stove limit? limit.
NO
terminal 3 of fan of fan motor
motor centrifugal centrifugal switch
switch? and terminal 14 of
motor control relay.
NO
YES
(10)
(5)
NO Correct wiring
Is there voltage across
between heater
the coil(s) of the heater
Is there voltage across contactor and stove
YES contactor(s)?
terminals 3 & 5 of limit.
Replace fan motor.
fan motor centrifugal switch?
YES
NO
TMB2006S
102 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Hybrid Timer Control Troubleshooting
(11)
YES
(12)
YES
(13)(14)(15)
NO Check for
Is there voltage across
proper operation of
L3 & L1, L1 & L2 and
contactors, replace
L2 & L3?
them if necessary.
YES
(15)
NO
Is the airflow switch Replace airflow
working properly? switch
(16)
YES
TMB2053S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 103
Hybrid Timer Control Troubleshooting
TMB2234S
10
6
7
4
9
3
2
1
104 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Hybrid Timer Control Troubleshooting
12 11
13 14 15
TMB2050S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 105
Hybrid Timer Control Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
106 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Section 8
On Premise Micro Control Troubleshooting
Models with OM Control Suffix
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 107
On Premise Micro Control (OM) Troubleshooting
Control Has No
Display Gas, steam and electric heat.
Single and three phase power supply.
(1)
(3)
Is there Yes
120 VAC at No Replace primary
output side of the fuse(s).
primary fuses? Is the No
control fuse Replace
functional? control fuse.
Yes
(4) Yes
Is there
120 VAC across Correct wiring
No between primary Replace
terminals 1 & 2 of control.
transformer fuse and
primary? transformer.
Yes
TMB2251S
108 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
5
6
TMB2280S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 109
On Premise Micro Control (OM) Troubleshooting
Door Open
Indicator Gas, steam and electric heat. Reference voltage
Single and three phase power supply. checks to transformer
neutral.
(1)
Is there
24 VAC between Yes (5)
Replace control.
H2-8 and
Is there
H2-9?
24 VAC across No Replace
terminals 2 & transformer.
3 of transformer
No secondary?
Is there
No Plug unit in and Yes
power supplied
to the unit? start cycle. (6)
Is there Correct wiring
24 VAC at the No between
input of the secondary
Yes
secondary fuse and
(2) fuse? transformer.
Is there Correct wiring
No between primary
120 VAC at input
of primary fuses? fuses and power Yes
supply. (7)
Is there
24 VAC at output No Replace
Yes
(3) side of secondary secondary fuse.
fuse?
Is there
120 VAC at No Replace primary
output side of the fuse(s).
primary fuses? Yes
(8)
Continued on
Yes next page
TMB2252S-a
110 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
Continued from
previous page
(9)
Yes
(10)
Is there Correct wiring
24 VAC at COM No between N.O. on
of lint panel door switch and
switch? COM on lint panel
switch.
Yes
(11)
Is there
24 VAC at N.O. Check lint panel
No switch for proper
of lint panel switch
with lint panel operation, replace
closed? if necessary.
Yes
Correct wiring
between H2-8 of
electronic control
and N.O. of lint
panel switch.
TMB2252S-b
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 111
On Premise Micro Control (OM) Troubleshooting
2 3 4
8 9 10 11
TMB2280S
112 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
Yes
Yes
(4)
(2)
Is there Is there
24 VAC across No Correct wiring supply voltage at No Replace motor
the coil of the motor to coil of black wire on the
control relay.
control relay? motor relay . motor control
relay?
Yes
Yes
Note: For high voltage three (5)
Single
phase supply (200 volts or
Is the unit phase
higher), the motor is Is there supply Correct wiring
supplied by L1, L2, equipped with single No between motor
voltage across
L3 through the motor phase or three phase and motor
terminals 1 & 4 of
contactor terminals T1, power? control relay.
the motor?
T2, T3. Make the appropriate
adjustments when doing
voltage checks. 3 phase Yes
Replace
(6)
motor.
Is there
Correct wiring
supply voltage No between L1, L2,
at terminals 5, 3 and 1
at the motor L3 and power (8)
contactor? supply.
Is there
supply voltage Correct wiring
Yes between L1-L2, L2-L3 No between motor
(7) and L1-L3 and T1-T2, and motor
T2-T3 and T1-T3 contactor.
Is there of motors?
supply voltage Yes
at terminals 6, 4 and 2 Replace motor
on the motor control relay.
contactor? Yes
Replace
motor.
No TMB2282S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 113
On Premise Micro Control (OM) Troubleshooting
1 2
TMB2280S
114 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
TMB2281S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 115
On Premise Micro Control (OM) Troubleshooting
Note: Tests are conducted with All voltage checks are referenced
Unit Will Not
unit running and calling for heat. to transformer neutral.
Heat Gas
(6)
(1)
Is the Is there Correct wiring
Is there No Yes No between motor
thermistor voltage to terminal 3
voltage at H2-5 of the motor terminal 3 and
operational?
of control? contactor? motor contactor.
No
Yes Yes
(7)
Replace Replace
control. Is there Check motor for
thermistor. No
(2) voltage at terminal proper operation.
5 of the fan Replace if
Is there
Correct wiring motor? necessary.
voltage to the No between airflow
common of the
switch and
airflow
cabinet limit.
switch?
(8)
Is
there Correct wiring
Yes No
voltage to the between cabinet
(3)
input of the limit and terminal
Is there Check for proper cabinet 5 of fan motor.
voltage to the No operation of limit?
N.O. terminal airflow switch.
of the airflow Replace if Yes
switch? necessary.
(9)
Is
there Check cabinet
Yes No limit for proper
voltage to the
(4) output of the operation.
cabinet Replace
Is there if necessary.
No Correct wiring limit?
voltage on BRN
wire on motor between H2-5 and
contactor? motor contactor. Yes
(10)
Yes Is there Correct wiring
voltage to the No between stove
(5)
input of the limit 1 and normally
Is stove limit 1? open terminal of
there No the airflow switch.
voltage at ORG/WHT Replace motor
wire on motor contactor.
contactor? Yes
Continued on
Yes next page TMB2283S-a
116 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
Continued from
previous page
Yes
(11) (16)
Is there Check operation Is there Correct wiring
voltage to the No of stove limit 1. voltage across No between gas
output side of the Replace if the coils of the valve and
stove limit 1? necessary. gas valve? ICM board.
Yes Yes
(12)
Yes
Yes
(13)
Is there Replace high
Check operation Does the igniter No
voltage to the No voltage ignition
of stove limit 2. spark? cable, igniter or
output side of the
Replace if ICM board.
stove limit 2?
necessary.
Yes
Yes
(14)
Is there
voltage to Correct wiring
No Is there a Yes Unit
terminal 2 of the between terminal 2
Ignition Control of ICM and stove flame? operational.
Module limit.
(ICM)?
Yes No
(15) Note: Make sure unit is
not in a lockout condition.
Is there
voltage at No Replace
terminal 1 of ICM board.
ICM board?
Yes TMB2283S-b
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 117
On Premise Micro Control (OM) Troubleshooting
4 5 6 7 8 9 10 11 12 13
14 16
2 3
15
TMB2280S
118 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
Note: Tests are conducted with All voltage checks are referenced
Unit Will Not
unit running and calling for heat. to transformer neutral.
Heat Steam
Yes
(1) (6)
Continued on
Yes next page
(5)
Is
there No
voltage at ORG/WHT Replace motor
wire on motor contactor.
contactor?
Yes TMB2284S-a
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 119
On Premise Micro Control (OM) Troubleshooting
Continued from
previous page
(10)
Yes
Does the
No Replace the
steam valve
steam valve
coil have
coil.
continuity?
Yes
Yes
Replace or
rebuild the
steam valve.
TMB2284S-b
120 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
4 5 6 7 8 9
2 3
10
TMB2280S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 121
On Premise Micro Control (OM) Troubleshooting
Note: Tests are conducted with All voltage checks are referenced
Unit Will Not
unit running and calling for heat. to transformer neutral.
Heat Electric
(6)
(1)
Is the Is there Correct wiring
Is there No Yes No between motor
thermistor voltage to terminal 3
voltage at H2-5 of the motor terminal 3 and
operational?
of control? contactor? motor contactor.
No
Yes Yes
(7)
Replace Replace
control. Is there Check motor for
thermistor. No
(2) voltage at terminal proper operation.
5 of the fan Replace if
Is there
Correct wiring motor? necessary.
voltage to the No between airflow
common of the
switch and
airflow
cabinet limit.
switch?
(8)
Is
there Correct wiring
Yes No
voltage to the between cabinet
(3)
input of the limit and terminal
Is there Check for proper cabinet 5 of fan motor.
voltage to the No operation of limit?
N.O. terminal airflow switch.
of the airflow Replace if Yes
switch? necessary. (9)
Is
there Check cabinet
Yes No limit for proper
voltage to the
(4) output of the operation.
cabinet Replace
Is there if necessary.
No Correct wiring limit?
voltage on BRN
wire on motor between H2-5 and
contactor? motor contactor. Yes
(10)
Yes Is there Correct wiring
voltage to the No between stove
(5)
input of the limit and normally
Is stove limit ? open terminal of
there No the airflow switch.
voltage at ORG/WHT Replace motor
wire on motor contactor.
contactor? Yes
Continued on
Yes next page TMB2286S-a
122 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
Continued from
previous page
(14)(15)
(11)
Check for proper
Is there supply operation of
Is there Check operation No
No voltage across T1-T2, contactors,
voltage to the of stove limit. T2-T3 and T1-T3 ? replace them if
output side of the Replace if
stove limit? necessary. necessary.
Yes
Yes
(12)
Check elements
Is there supply for shorts or
voltage to the L3-L1, No Correct wiring Do all elements No
produce heat (glow opens. Check
L1-L2 and L3-L2 between HC2 and
a slight orange wires between
terminals of HC2? line voltage.
color)? contactors and
elements.
Yes Yes
(13)
Is there supply
voltage to the L1-L2, No Correct wiring Unit
L2-L3 and L1-L3 between HC1 and operational.
terminals of HC1? line voltage.
Yes
TMB2286S-b
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 123
On Premise Micro Control (OM) Troubleshooting
12 13
14 15
6 7 8 9 10 11
2 3 4 5
TMB2285S
124 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 125
Section 9
Quantum Control Troubleshooting
Models with LC, LX, LY, WC, WX and WY Control Suffixes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
126 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
Yes Yes
E:OF
- Is IR communication disabled
by manual programming?
- Is the IR window on the control
covered or blocked?
- If needed, change control
board.
TMB2269S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 127
Quantum Control Troubleshooting
No
Yes
Yes
No
TMB1794S
128 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
52. No Display
(1)
No
(2)
No
Is the secondary fuse
Replace the fuse.
good?
Yes
(3)
No
(4)
No
(5)
No
Is the primary fuse Replace the primary
good? fuse.
Yes
TMB2299S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 129
Quantum Control Troubleshooting
No Display
2 1
4
TMB2295S
130 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
No
TMB2271S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 131
Quantum Control Troubleshooting
10
9
2 3 4
TMB2295S
T
132 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
54. No Start/Run
*Note: For steps 2 and 3. For 208/240 1 phase, both lines to the motor
are controlled by contacts. Please check second set of contacts.
For 3 phase units, the three legs supplied to the moter will be
controlled by N.O. contacts. Please check all three legs.
(1)
No
(2) (5)
No No
(3) (6)
Yes No
(4)
No
TMB2272S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 133
Quantum Control Troubleshooting
No Start/Run
3 3
2 2
1 1 5
6
4
TMB2295S
134 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
No Correct wiring
Is there voltage at between H5-13 and
H5-13 of control? Yes
N.O. of airflow
switch.
(7)
Yes
No Correct wiring
Replace Is there voltage to the
Replace between cabinet
control. input of the cabinet
thermistor. limit and terminal 5
(2) limit?
of fan motor.
Is there voltage No No
Yes
at H5-1 of
control?
(9)
Yes
Correct wiring
No
Is there voltage to the between cabinet limit
input of the stove limit? and stove limit
(4) thermostat.
Is there voltage at No
the output terminal Replace relay. Yes
of the fan motor
relay?
(10)
Yes
Is there voltage to the No Check operation of
output side of the stove stove limit. Replace
(5) limit? if necessary.
Check wiring
Is there voltage at No between
terminal 3 of the fan motor terminal 3 Yes
motor? and motor
relay.
Yes
Continued on next
page
TMB2275S-a
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 135
Quantum Control Troubleshooting
Yes
Continued from Is there a flame? Unit operational.
previous page
No
(11)
Yes
Note: Make sure unit is
not in a lockout
(12) condition.
Is there voltage at No
terminal 1 of ICM Replace ICM board.
board?
Yes
(13)
Yes
Yes
No Replace high
Does the igniter spark? voltage ignition
cable or igniter.
Yes
TMB2275S-b
136 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
3 4 5 6
8 7
10 9
TMB2295S
11 12 13
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 137
Quantum Control Troubleshooting
(1) (6)
Yes Yes
Replace
Replace
control.
thermistor. (7)
(2)
No Correct wiring
Is there voltage No No Is there voltage to the
between cabinet
at H5-1 of input of the cabinet
limit and terminal 5
control? limit?
of fan motor.
Is the Yes
thermistor
operational? Yes
Yes
(3) (8)
No Check cabinet
No Correct wiring Is there voltage to the
Is there voltage at input limit for proper
between input output of the cabinet
terminal of the motor operation. Replace
terminal and H5-1. limit?
control relay? if necessary.
Yes Yes
(4) (9)
Yes Yes
(5)
Verify that the correct
steam is supplied to the
Check wiring unit. Verify that the steam
Is there voltage at No
between motor valve and other items were
terminal 3 of the fan
terminal 3 and installed according to the
motor?
motor relay. Installation Manual.
Yes
TMB2276S
138 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
3 4 5 6
TMB2295S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 139
Quantum Control Troubleshooting
(1) (6)
Yes
Yes
Replace
Replace
control.
thermistor. (7)
(2)
No Correct wiring
Is there voltage No No Is there voltage to the
between cabinet
at H5-1 of input of the cabinet
limit and terminal 5
control? limit?
of fan motor.
Is the Yes
thermistor
operational? Yes
Yes
(3) (8)
No Check cabinet
No Correct wiring Is there voltage to the
Is there voltage at input limit for proper
between input output of the cabinet
terminal of the motor operation. Replace
terminal and H5-1. limit?
control relay? if necessary.
Yes Yes
(4) (9)
Correct wiring
Is there No between stove limit
No Is there voltage to the
voltage at the and normally open
Replace relay. input of the stove limit?
output terminal of the fan terminal of the
motor relay? airflow switch.
Yes Yes
(5) (10)
Yes Yes
Continued on next
page
TMB2277S-a
140 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
Continued from
previous page
(11)
No Correct wiring
Is there voltage across
between heater
the coil(s) of the heater
contactor and
contactor(s)?
stove limit.
Yes
(12)
Yes
(13)
Yes
Yes
Unit is operational.
TMB2277S-b
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 141
Quantum Control Troubleshooting
12 12 12
2
13 13 13
1
3 4 5 6
8 7
11
10 9
TMB2296S
142 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
No No
(2) (6)
Is there
Yes Correct wiring Yes Replace primary
Is there voltage coming line voltage on the
between fuse F4 fuse.
out of fuse F4? input side of primary
and control.
fuse?
No No
(2)
Verify that unit is
plugged in. Correct
No wiring between
Is fuse F4 good? Replace fuse. supply terminals
and fuse F1.
Yes
(3)
Correct wiring
Is there voltage across Yes
between
terminals 1 and 4 of
transformer
the transformer?
and fuse.
No
(4)
Check transformer
Is line voltage supplied Yes
for operation.
to the transformer
Replace if
primary?
necessary.
No
TMB2288S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 143
Quantum Control Troubleshooting
CE Models No Display
5
4
3
2
1
TMB2297S
144 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
(1) (6)
No
No
(2) (7)
Is there
Is
voltage at Yes Correct wiring Yes
there voltage to
COM terminal of lint between loading Replace fuse.
input side
door switch door and control.
of F3?
(LDS)?
No No
(3) (8)
No No
(4) (9)
Is
there voltage Yes Is there Yes
Correct wiring Replace
at COM terminal voltage supplied to the
between DS transformer.
of door switch primary of the
and LDS.
(DS)? transformer?
No No
(5)
(10)
Make sure door Verify primary fuses are good. Replace
Is there Yes is closed. if necessary. Check and correct wiring
voltage at N.C. terminal Check function between power terminal block and
of DS? of DS. Replace if transformer. Verify machine has
necessary. supply voltage.
No
TMB2289S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 145
Quantum Control Troubleshooting
10
8
9
6
1
TMB2297S
146 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
(1) (4)
No No
(2) (5)
Is
there voltage on the Is
Yes Correct wiring there voltage across Yes Correct wiring
output side of the between motor relay between control and
motor relay terminals? H5-3 and H5-4 of the
and motor. control? motor relay.
Check to common
line.
No No
(3) (6)
Is Is
there voltage on the No Correct wiring from there voltage to Yes Press start button.
input side of the motor line supply voltage H5-7 on the If machine doesnt
relay terminals? to motor relay. control? start, replace
Check to common control.
line.
Yes No
Correct wiring to
control. Refer to
CE Models Door
Open Indicator.
TMB2291S
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 147
Quantum Control Troubleshooting
CE Models No Start/Run
3 3
2 2
1 1
6 5
TMB2297S
148 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
(1) (7)
Check airflow
No switch (AFS) for No
Is there voltage to input Correct wiring
Is there voltage on proper operation.
side of the cabinet limit between stove limit
H5-13 on the control? If needed correct
(CT)? and MCS.
wiring between
AFS and H5-13.
Yes Yes
(2) (8)
Correct wiring
Is there voltage at No between H5-1 on No Correct wiring
Is there voltage to between ST-1
terminal 14 of the the control and
input of ST-1? and CT.
K2 relay? terminal 14 of
K2.
Yes Yes
(4) (10)
Yes Yes
(5) (11)
Is
there voltage to Correct wiring Correct wiring
No Is there voltage on No
the COM terminal of between K2 relay between
terminal 4 of ignition
motor centrifical switch and MCS. terminal 4
control module?
(MCS)? and ST-1.
Yes Yes
(6) (12)
Yes Yes
Continued on next
TMB2292S-a
page
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 149
Quantum Control Troubleshooting
Continued from
previous page
(GAS)
(13)
No
Verify control is
NOT going into lock-out.
Correct wiring between
valve and ICM. Replace
ICM if necessary.
Continued from
previous page
(Steam)
(14)
No
TMB2292S-b
150 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
1
7 2
3
4
5
11 12
10 9
13
TMB2297S
14
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 151
Quantum Control Troubleshooting
(1) (7)
Check airflow
No switch (AFS) for No
Is there voltage to input Correct wiring
Is there voltage on proper operation.
side of the cabinet limit between stove limit
H5-13 on the control? If needed correct
(CT)? and MCS.
wiring between
AFS and H5-13.
Yes Yes
(2) (8)
Yes Yes
(3) (9)
Correct wiring
Is there voltage at No Is No Correct wiring
between H5-1 on
terminal 14 of the there voltage to between ST and
the control and
K2 relay? input of ST? CT.
terminal 14 of K2.
Yes Yes
(4) (10)
Yes Yes
(5)
Yes
(6)
No Check MCS
Is there voltage to the
for proper operation.
output side of the
Replace motor
MCS?
if necessary.
Yes
TMB2294S-a
152 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting
Continued from
previous page
(11)
Yes
Do the No Replace
contactors
contactors.
pull in?
Yes
Yes
Yes
Yes
Unit operational.
TMB2294S-b
70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 153
Quantum Control Troubleshooting
1
2 3
4
5
11
8 7
10 9
TMB2298S
154 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601