Drying Tumblers

Troubleshooting
25 Pound Capacity
30 Pound Capacity
35 Pound Capacity
55 Pound Capacity
Starting Serial No. 0602004144
Refer to Page 7 for Model Numbers

1
SELEC
TEMP T
2
INSER
COIN T
3
PUSH
START

HIGH
TEMP

MED
STAR
T
25 C
TEMP

LOW
TEMP

NO
HEAT

Part No. 70380601R3


www.comlaundry.com September 2009
Table of Section 1 Safety Information ..........................................................
Locating an Authorized Service Person ...............................................
4
6
Safety Warnings and Decals................................................................. 6
Contents Safety Precautions for Servicing Tumblers .......................................... 6
Section 2 Introduction ..................................................................... 7
Model Identification ............................................................................. 7
Serial Plate Location............................................................................. 9
Customer Service.................................................................................. 9
Wiring Diagram .................................................................................... 9
How a Tumbler Works ......................................................................... 10
Section 3 Troubleshooting............................................................... 11
1. Tumbler Does Not Start ........................................................... 12
2. Motor Does Not Start............................................................... 13
3. Motor Overload Protector Cycles Repeatedly ......................... 14
4. Motor Runs But Cylinder Does Not Turn................................ 15
5. Motor Does Not Stop ............................................................... 16
6. Burner Does Not Ignite ............................................................ 17
7. Burner Ignites and Goes Out Repeatedly................................. 20
8. Burner Does Not Shut Off ....................................................... 21
9. Clothes Do Not Dry ................................................................. 22
10. Tumbler Overheating ............................................................... 24
11. Burner Not Burning Properly................................................... 25
12. Loading Door Opens During Operation................................... 26
13. Cylinder Continues to Spin with Door Open ........................... 27
14. Coin Does Not Fall into Coin Vault or Coin Drop Sensor Does Not
Register that Coin Has Been Entered28
Section 4 Adjustments ..................................................................... 29
15. Loading Door Switch ............................................................... 29
16. Loading Door Strike................................................................. 29
Section 5 Micro Display Control (MDC) Troubleshooting.......... 30
Models with BC, BL, BX and BY Control Suffixes
17. Coins Ignored When Entered................................................... 30
18. Control Has No Display........................................................... 31
19. Door Open Indicator ................................................................ 33
20. Motor Will Not Start/Run ........................................................ 35
21. Unit Will Not Heat Gas......................................................... 39
22. Unit Will Not Heat Steam..................................................... 42
23. Unit Will Not Heat Electric .................................................. 45
24. Error Codes .............................................................................. 48
Gas and Steam Models
Control Circuit Schematic.................................................................49
Control Circuit Connection ...............................................................50
Gas and Steam Models
Control Box Schematic .....................................................................51
Control Box Connection ...................................................................52

Copyright 2009, Alliance Laundry Systems LLC


All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without
the expressed written consent of the publisher.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 1


Gas and Steam Models
Control Circuit Schematic.................................................................53
Gas and Steam Models
Control Circuit Schematic.................................................................54
Gas and Steam Models
Control Box Schematic .....................................................................55
Control Box Connection ...................................................................56
Electric Models
Control Circuit Schematic.................................................................57
Control Circuit Connection ...............................................................58
Electric Models
Control Box Connection ...................................................................59
Control Box Schematic .....................................................................60
Section 6 NetMaster Troubleshooting ........................................... 61
Models with NC, NR, NX, NY, ZC, ZR, ZX and ZY
Control Suffixes
25. No Infra-red (IR) Communication ........................................... 61
26. Coins Ignored When Entered................................................... 62
27. Control Has No Display........................................................... 63
28. Door Open Indicator ................................................................ 65
29. Motor Will Not Start/Run ........................................................ 67
30. Unit Will Not Heat Gas......................................................... 71
31. Unit Will Not Heat Steam..................................................... 74
Section 7 Hybrid Timer Control Troubleshooting ....................... 76
Models with QT, SD and SX Control Suffixes
32. Coins Ignored When Entered................................................... 76
33. Control Has No Display OPL Models .................................. 77
34. Display Flashes dr With Door Closed OPL Models ......... 80
35. Vend Satisfied, No In Use LED Coin Models ...................... 83
36. In Use LED Lit, No Motor Run Coin Models ...................... 87
37. Motor Will Not Start/Run Coin Models ............................... 90
38. Motor Will Not Start/Run OPL Models................................ 93
39. Unit Will Not Heat Gas Coin Models................................ 96
40. Unit Will Not Heat Gas OPL Models ................................ 99
41. Unit Will Not Heat Electric OPL.......................................... 102
42. Error Codes .............................................................................. 106
Section 8 On Premise Micro Control Troubleshooting................ 107
Models with OM Control Suffix
43. Control Has No Display........................................................... 108
44. Door Open Indicator ................................................................ 110
45. Motor Will Not Start/Run ........................................................ 113
46. Unit Will Not Heat Gas......................................................... 116
47. Unit Will Not Heat Steam..................................................... 119
48. Unit Will Not Heat Electric .................................................. 122
49. Error Codes .............................................................................. 125

2 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Section 9 Quantum Control Troubleshooting............................... 126
Models with LC, LX, LY, WC, WX and WY Control Suffixes
50. No Infrared Communication .................................................... 127
51. Coins Ignored When Entered................................................... 128
52. No Display ............................................................................... 129
53. Door Open Indicator............................................................. 131
54. No Start/Run ............................................................................ 133
55. Unit Will Not Heat Gas......................................................... 135
56. Unit Will Not Heat Steam..................................................... 138
57. Unit Will Not Heat Electric .................................................. 140
58. CE Models No Display ............................................................ 143
59. CE Models Door Open Indicator.......................................... 145
60. CE Models No Start/Run ......................................................... 147
61. CE Models Will Not Heat Gas/Steam................................... 149
62. CE Models Will Not Heat Electric ....................................... 152

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 3


Section 1
Safety Information
Throughout this manual and on machine decals, you
will find precautionary statements (CAUTION, WARNING
WARNING, and DANGER) followed by specific
instructions. These precautions are intended for the Failure to install, maintain and/or operate
personal safety of the operator, user, servicer, and those this product according to the
maintaining the machine. manufacturers instructions may result in
conditions which can produce serious
injury, death and/or property damage.
DANGER Do not repair or replace any part of the
product or attempt any servicing unless
Danger indicates an imminently hazardous specifically recommended or published
situation that, if not avoided, will cause in this Service Manual and unless you
severe personal injury or death. understand and have the skills to carry
out the servicing.
Whenever ground wires are removed
during servicing, these ground wires
WARNING must be reconnected to ensure that the
product is properly grounded and to
Warning indicates a hazardous situation reduce the risk of fire, electric shock,
that, if not avoided, could cause severe serious injury or death.
personal injury or death. W006R2

CAUTION
Caution indicates a hazardous situation
that, if not avoided, may cause minor or
moderate personal injury or property
damage.

Additional precautionary statements (IMPORTANT


and NOTE) are followed by specific instructions.
IMPORTANT: The word IMPORTANT is used
to inform the reader of specific procedures where
minor machine damage will occur if the procedure
is not followed.
NOTE: The word NOTE is used to communicate
installation, operation, maintenance or servicing
information that is important but not hazard
related.
In the interest of safety, some general precautions
relating to the operation of this machine follow.

4 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Safety Information

IMPORTANT INFORMATION: During the NOTE: The WARNING and IMPORTANT


lifetime of a tumbler, it may require service. The instructions appearing in this manual are not meant
information contained in this manual was written to cover all possible conditions and situations that
and is intended for use by qualified service may occur. It must be understood that common
technicians who are familiar with the safety sense, caution and carefulness are factors which
procedures required in the repair of a tumbler, and CANNOT be built into this tumbler. These factors
who are equipped with the proper tools and testing MUST BE supplied by the person(s) installing,
equipment. maintaining or operating the tumbler.
Always contact your dealer, distributor, service agent
or the manufacturer on any problems or conditions you
WARNING do not understand.
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
Disconnect electric power to the tumbler
before servicing.
Never start the tumbler with any guards/
panels removed.
Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.
W240

WARNING
Repairs that are made to your products by
unqualified persons can result in hazards
due to improper assembly or adjustments
subjecting you, or the inexperienced
person making such repairs, to the risk of
serious injury, electrical shock, or death.
W007

CAUTION
If you or an unqualified person perform
service on your product, you must assume
the responsibility for any personal injury or
property damage which may result. The
manufacturer will not be responsible for
any injury or property damage arising from
improper service and/or service
procedures.
W008

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 5


Safety Information

Locating an Authorized Service Safety Precautions for Servicing


Person Tumblers
Alliance Laundry Systems is not responsible for
personal injury or property damage resulting from Prior to servicing tumbler:
improper service. Review all service information Disconnect electrical service and lockout to
before beginning repairs. prevent unintentional connection.
Warranty service must be performed by an Shut off supply gas valve.
authorized technician, using authorized factory Allow machine to cool prior to servicing.
parts. If service is required after the warranty
expires, Alliance Laundry Systems also After servicing tumbler:
recommends contacting an authorized technician
and using authorized factory parts. Control/access panels must be reinstalled.
Motor/drive/belt guards must be reinstalled.
Safety Warnings and Decals
Contactor/junction/accessory box covers must
SAFETY WARNINGS and decals have been provided be reinstalled.
in key locations to remind you of important precautions
for the safe operation and maintenance of your tumbler. Use a non-corrosive leak detection solution to
Please take the time to review these warnings before check all pipe connections for gas leaks. DO
proceeding with service work. NOT USE AN OPEN FLAME TO CHECK
FOR GAS LEAKS!
All decals have been designed and applied to withstand
washing and cleaning. Decals should be checked The loading door switch, lint door switch and
periodically to be sure they have not been damaged, airflow switch must be operating properly.
removed, or painted.

6 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Section 2
Introduction
Model Identification
Information in this manual is applicable to these models:
Gas Steam Electric
CHD25G2-CA025L HT025L PA025N CHD25S2-CT025S CHD25E2-CT025E
CHD25G2-CA025N HT025N PT025L CHD25S2-CU025S CHD25E2-CU025E
CHD25G2-CT025L HU025L PT025N DR25S2-BT025S DR25E2-BT025E
CHD25G2-CT025N HU025N PU025L DR25S2-BU025S DR25E2-BU025E
CHD25G2-CU025L IPD25G2-IT025L PU025N GT025S GT025E
CHD25G2-CU025N IPD25G2-IT025N SA025L GU025S GU025E
DR25G2-BA025L KA025L SA025N HT025S HT025E
DR25G2-BA025N KA025N ST025L HU025S HU025E
DR25G2-BT025L KT025L ST025N IPD25S2-IT025S IPD25E2-IT025E
25 DR25G2-BT025N KT025N SU025L KT025S KT025E
Pound DR25G2-BU025L KU025L SU025N KU025S KU025E
DR25G2-BU025N KU025N UA025L LT025S LT025E
GA025L LA025L UA025N LU025S LU025E
GA025N LA025N UT025L PT025S PT025E
GT025L LT025L UT025N PU025S PU025E
GT025N LT025N UU025L ST025S ST025E
GU025L LU025L UU025N SU025S SU025E
GU025N LU025N YT025L UT025S UT025E
HA025L PA025L YT025N UU025S UU025E
HA025N YT025S YT025E
CHD30G2-CA030L HA030L PT030L CHD30S2-CT030S CHD30E2-CT030E
CHD30G2-CA030N HA030N PT030N CHD30S2-CU030S CHD30E2-CU030E
CHD30G2-CT030L HT030D PU030L DR30S2-BT030S DR30E2-BT030E
CHD30G2-CT030N HT030L PU030N DR30S2-BU030S DR30E2-BU030E
CHD30G2-CU030L HT030N SA030L GT030S GT030E
CHD30G2-CU030N HU030L SA030N GU030S GU030E
DR30G2-BA030L HU030N ST030D HT030S HT030E
DR30G2-BA030N IPD30G2-IT030L ST030L HU030S HU030E
DR30G2-BT030D IPD30G2-IT030N ST030N IPD30S2-IT030S IPD30E2-IT030E
30 DR30G2-BT030L KT030L SU030L KT030S KT030E
Pound DR30G2-BT030N KT030N SU030N LT030S LT030E
DR30G2-BU030L LA030L UA030L LU030S LU030E
DR30G2-BU030N LA030N UA030N PT030S PT030E
GA030L LT030L UT030L PU030S PU030E
GA030N LT030N UT030N ST030S ST030E
GT030L LU030L UU030L SU030S SU030E
GT030N LU030N UU030N UT030S UT030E
GU030L PA030L YT030L UU030S UU030E
GU030N PA030N YT030N YT030S YT030E
Models continued on next page.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 7


Introduction

Gas Steam Electric


AT035L HA035L PA035L AT035S AT035E
AT035N HA035N PA035N CHD35S2-CT035S CHD35E2-CT035E
CHD35G2-CA035L HT035L PT035L CHD35S2-CU035S CHD35E2-CU035E
CHD35G2-CA035N HT035N PT035N DR35S2-BT035S DR35E2-BT035E
CHD35G2-CT035L HU035L PU035L DR35S2-BU035S DR35E2-BU035E
CHD35G2-CT035N HU035N PU035N GT035S GT035E
CHD35G2-CU035L IPD35G2-IT035L SA035L GU035S GU035E
CHD35G2-CU035N IPD35G2-IT035N SA035N HT035S HT035E
DR35G2-BA035L KA035L ST035L HU035S HU035E
DR35G2-BA035N KA035N ST035N IPD35S2-IT035S IPD35E2-IT035E
35 DR35G2-BT035L KT035L SU035L KT035S KT035E
Pound DR35G2-BT035N KT035N SU035N KU035S KU035E
DR35G2-BU035L KU035L UA035L LT035S LT035E
DR35G2-BU035N KU035N UA035N LU035S LU035E
GA035L LA035L UT035L PT035S PT035E
GA035N LA035N UT035N PU035S PU035E
GT035L LT035L UU035L ST035S ST035E
GT035N LT035N UU035N SU035S SU035E
GU035L LU035L YT035L UT035S UT035E
GU035N LU035N YT035N UU035S UU035E
YT035S YT035E
YU035S YU035E
CA055L HT055L ST055L CT055E
CA055N HT055N ST055N CU055E
CT055L HU055L SU055L GT055E
CT055N HU055N SU055N HT055E
CU055L IPD55G2-IT055L UA055L Not HU055E
55 CU055N IPD55G2-IT055N UA055N Applicable IPD55E2-IT055E
Pound GT055L KT055L UT055L KT055E
GT055N KT055N UT055N ST055E
HA055L SA055L UU055L SU055E
HA055N SA055N UU055N UT055E
HT055D ST055D UU055E

Includes models with the following control suffixes:


3O DX4 OPL LC network adaptable coin SX single drop, prep for coin
3V DX4 vended LX network adaptable, prep for coin WC network ready coin
3X DX4 prep for coin LY network adaptable, prep for card WX network ready, prep for coin
BC basic electronic, coin NC NetMaster coin WY network ready, prep for card
BL basic electronic, central pay NR NetMaster card ZC NetMaster network coin
BX basic electronic, prep for coin NX NetMaster, prep for coin ZR NetMaster network card
BY basic electronic, prep for card NY NetMaster, prep for card ZX NetMaster network, prep for coin
DO DMP OPL OM OPL micro ZY NetMaster network, prep for card
DV DMP vended QT dual digital timer
DX DMP prep for coin SD single drop

8 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Introduction

Serial Plate Location


When calling or writing about your product, be sure to
mention model and serial numbers. Model and serial
numbers are located on serial plate as shown.

TMB2098N

1 Serial Plate

Customer Service
If literature or replacement parts are required, contact
the source from which the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized parts
distributor.
For technical assistance, call (920) 748-3121.

Wiring Diagram
The wiring diagram is located inside the contactor or
junction box.
The wiring diagram part number is located in the lower
portion of the electrical data on the serial plate.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 9


Introduction

How a Tumbler Works


A tumbler uses heated air to dry loads of laundry.

1 When the motor is started, the exhaust fan pulls


1
room temperature air in through the air intake at
the rear of the tumbler and over the heat source
(burner flame for gas, heating element for
2
electric, and coil for steam).

2 The heated air moves into the cylinder, where it is


circulated through the wet load by the tumbling
action of the cylinder.

3 The air then passes through the lint filter, exhaust


fan, and is vented to the outdoors.

T001CE3A

10 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Section 3
Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

IMPORTANT: Refer to wiring diagram for aid in


testing tumbler components.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 11


Troubleshooting

1. Tumbler Does Not Start

Tumbler Does
Not Start

Is motor Is the
Yes Test relay and Press and
relay START button
replace if hold
inoperative? not properly Yes
necessary. START button
activated
(Hybrid Timer for three
Models)? seconds.
No

Is Yes Close loading


loading door No
door
open? completely.

No Is the
electrical power Yes Check power
off or circuit supply, or
breaker or fuse replace fuses.
Is blown?
drying timer in
Yes Turn drying
an off position
(Hybrid Timer timer on.
No
Models)?

No Is the lint Yes Close and


panel lock lint
open? panel.

Is there an
Check that No
incorrect Yes proper amount
amount of coins
of coins are
inserted into
inserted.
coin drop?

Is there a Check fuse


Yes (in junction box)
blown fuse
No on tumbler? and replace if
necessary.

Yes Test coin drop


Is coin drop
and replace if
inoperative?
inoperative.

No
TMB2036S

12 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

2. Motor Does Not Start

Motor Does
Not Start
Is there
broken, loose, Yes Refer to wiring
or incorrect diagram.
wiring?

Is the No
electrical power Yes Check power
off or circuit supply, or replace
breaker fuse fuses. Is
blown? the fan or fan Yes Replace fan or
motor motor assembly.
binding?
No

No
Is the
loading door Close door, panel
switch or lint Yes or test switch and
panel switch not Is the
replace if Yes Replace cylinder,
closed or switch cylinder or
inoperative. bearing, rollers, or
inoperative? cylinder motor
motor assembly.
binding?

No No

Is the Refer to
door switch Yes Is the
Adjustments Yes
improperly transformer Test and replace
Section for door
adjusted? inoperative? if necessary.
switch adjustment.

No No

Is the
motor relay Yes Test relay and replace
Is the start Yes Press and hold
circuit not START button for inoperative? if inoperative.
complete? three seconds.

No
No

Is the
Yes Have motor tested airflow switch Yes Test switch,
Is the motor
and replace if inoperative replace or adjust
inoperative?
inoperative. (Hyrid Timer as required.
Models)?

No
TMB2037S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 13


Troubleshooting

3. Motor Overload Protector Cycles Repeatedly


Motor Overload
Protector
Cycles
Repeatedly

Refer to
Is voltage Yes Installation
correct? Manual for
electrical
requirements.
No

Is clothes Yes
load too Remove part of
large? load.

No

Is clothes Yes
cylinder Check cylinder
binding? for binding.

No
Check with
local power
Is wiring Yes company to
adequate? ensure that
wiring is
adequate.
No
Refer to
Yes Installation
Is make-up
Manual for
air adequate?
make-up air
requirements.

No
Clean lint
accumulation
Is there lint
Yes on and around
buildup around
the motors.
tumbler or poor
maintenance?

Is there
broken, loose Yes Refer to wiring
No or incorrect diagram.
wiring?

TMB1904S

14 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

4. Motor Runs But Cylinder Does Not Turn

Motor Runs
But Cylinder
Does Not Turn

Is cylinder Yes Replace


belt
cylinder belt.
broken?

No

Is cylinder Yes Check cylinder


binding? for binding.

TMB1905S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 15


Troubleshooting

5. Motor Does Not Stop

Motor Does
Not Stop

Is the door
switch or lint Yes Test switches
panel switch and replace if
not working inoperative.
properly?

No

Is coin drop Test coin drop


Yes
not working and replace if
properly? inoperative.

No

Is wiring Yes Refer to wiring


incorrect? diagram.

No

Is electronic Yes Replace


control electronic
inoperative? control.

No

Is motor Yes Test relay and


relay replace if
inoperative? inoperative.

TMB2038S

16 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

6. Burner Does Not Ignite

Burner Does
Not Ignite Is
stove limit Yes Test thermostat 2
thermostat 2 and replace if
inoperative? inoperative.

Is there Refer to
an improper or Yes Installation
Manual for No Open partially closed
inadequate exhaust
exhaust system gas shut-off valve, or
system?
requirements. correct low gas
pressure. Check
Is manifold pressure
No Yes and adjust to
there an
insufficient gas pressure specified on
supply? serial plate. If
Are there pressure cannot be
blown fuses or Yes obtained, have your
Check fuses or
tripped circuit breakers local gas company
circuit breaker.
in external electric No check main gas
supply line? pressure.

No Tumbler is equipped
for type of gas
Is
Are the specified on serial
drying Yes
orifices plate. If orifices are
selector in the Yes Reset switch on
incorrect? different from that
Cool Down microprocessor. specified on serial
portion of
plate, obtain and
cycle?
No install correct orifices.

No
Clean lint
Is compartment. Check
the cabinet Yes Test thermostat Is there Yes damper for lint
thermostat and replace if lint
accumulation. Check
inoperative? inoperative. buildup?
ductwork for lint
buildup.
No
No

Refer to Installation
Is Is there Manual to ensure
stove limit Yes Test thermostat 1 inadequate Yes that ductwork and
thermostat 1 and replace if ductwork and make-up air
inoperative? inoperative. make-up openings are sized
air? accurately.

No
No Continued on
next page

TMB2187S-a

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 17


Troubleshooting

6. Burner Does Not Ignite (continued)

Continued from Check fuse


previous page Is
Yes (located in
there a blown
control box)
fuse on
and replace if
tumbler?
necessary.

Is the Test switch No


Yes
airflow switch and replace
inoperative? if inoperative. Is
gas shut-off Yes
valve in the Open shut-
closed off valve.
No
position?

Is the lint Unlock and open No


panel not Yes lint panel. Close
closed panel ensuring a
properly? tight fit, then lock.
Is the
ground wire
from Instant Connect
No Electronic Ignition Yes
ground wire
(IEI) board not to ground
Is connected to terminal.
there broken, Refer ground
Yes
loose or incorrect to wiring terminal?
wiring? diagram.

No
No
Is the Yes
Is Clearance IEI control Replace IEI
there an should be inoperative? control.
Yes
improper igniter 0.110 - 0.140
to burner inch (2.79 - 3.55
clearance? mm). No

Is
No Yes
motor switch Replace motor.
inoperative?

Check valve
Are valve coils Yes
coils and
inoperative? replace if No
necessary.
Continued on
next page
No
TMB2187S-b

18 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

6. Burner Does Not Ignite (continued)

Continued from
previous page

Is there
an inoperative Yes Test and replace
microprocessor or as needed.
hybrid timer?

No

Is
wrong Check incoming
transformer Yes voltage and install
configuration correct
harness configuration
installed? harness.

No
Reset IEI control by
opening and closing
Is Instant loading door. (Non-
Electronic CE models only)
Yes
Ignition (IEI)
control in safety Reset IEI by
lockout? pressing reset
button on back of
unit. (CE models
only)

TMB2187S-c

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 19


Troubleshooting

7. Burner Ignites and Goes Out Repeatedly

Burner Ignites
and Goes Out
Repeatedly
Is
Yes
there excessive Refer to
igniter to burner Paragraph 43.
clearance?
Is there
Yes Check gas
insufficient
supply and
gas No
pressure.
pressure?

Refer to
Is Installation
No Yes
there inadequate Manual for
make-up air? make-up air
Is the requirements.
cabinet Yes Test thermostat
thermostat and replace if
inoperative? inoperative. No

No Is the
Yes Replace
thermistor
Refer to inoperative? thermistor.
Is the Installation
exhaust system Yes Manual for
improper or exhaust
inadequate? system No
requirements.

No Tumbler is equipped Is the control Yes


for type of gas heater relay Replace control.
specified on serial malfunctioning?
Does
tumbler have Yes plate. If orifices are
improper different from that
orifices? specified on serial
No
plate, obtain and
install correct
orifices.
No

Are the back


Is there Yes
Yes Refer to wiring draft dampers Repair damper to
broken, loose
diagram. locked in close working order.
or incorrect
position?
wiring?

No
TMB1908S

20 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

8. Burner Does Not Shut Off

Burner Does
Not Shut Off

Are there
impurities on gas Yes Replace gas
valve seat,
valve.
preventing valve
from closing?

No

Is wiring Yes Refer to wiring


correct? diagram.

No

Is control heater Yes Replace


relay
control.
malfunctioning?

TMB1909S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 21


Troubleshooting

9. Clothes Do Not Dry

Clothes Do Not
Dry

Does
the burner ignite Yes Refer to
Is there and go out Paragraph 7.
enough heating Start cycle again
Yes repeatedly?
time allocated for with enough time to
the load? dry load.
No

No Is
the drying Set selector
Yes
selector for higher
improperly setting.
Is the burner not Yes Refer to
set?
igniting? Paragraph 6.

No

No Is Yes Refer to Installation


the voltage Manual for electrical
incorrect? requirements.
Is there
too much water in Yes Remove excess
articles being water. No
dried?

Is there
Yes Refer to Installation
No inadequate Manual for make-up
make-up air requirements.
Remove part of air?
Is load. Maximum
the clothes Yes load is 25 pound No
load too dry weight (cotton
large? load) for 25 pound
Is the
Tumbler, etc. Yes
exhaust duct to Clean duct to
the outside remove blockage.
No
blocked?

Is the
Refer to Installation No
exhaust system Yes Manual for exhaust
improper or
system
inadequate?
requirements.
Continued on
next page
No

TMB1910S-a

22 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

9. Clothes Do Not Dry (continued)

Continued from
previous page

Is the lint screen Yes Is the


Clean lint screen. exhaust Yes Adjust damper so it
clogged?
damper turns freely.
binding?

No No

Check belt is not


Is the thermistor Yes Is the
Replace thermistor. Yes riding on outer
inoperative? cylinder speed
diameter of motor
too fast?
pulley.

No
No

Check for proper


alignment: make
Is airflow switch
Yes sure locator pins
bracket mounted
are securely in
properly?
place and tighten
mounting screws.

TMB1910S-b

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 23


Troubleshooting

10. Tumbler Overheating

Tumbler Check wiring to


Overheating ensure thermistor
Is the
is connected.
thermistor Yes Replace
sensor
Does thermistor if
inoperative?
tumbler necessary.
Yes Obtain and install Remove lint build-
have incorrect correct orifices.
main burner up on thermistor.
orifices? No

Is the
No exhaust Adjust damper
Yes
damper so it turns
binding? freely.
Is gas Adjust gas pressure
Yes
pressure too high or as specified on
low? serial plate. No

Is the
No control heater
Yes
relay Replace control.
malfunctioning?
Is the Refer to Installation
Yes
make-up air Manual for make-up
inadequate? air requirements.
No

No Are
the safety covers
Yes
missing, allowing Replace covers.
Clean lint cool air to enter
compartment. Check tumbler?
Is there Yes damper for lint
lint buildup? accumulation. Check No
ductwork for lint
buildup.
Is the
No lint screen
Yes Replace lint
clogged with
screen.
Remove obstruction fabric
or lint build up from softener?
Is the exhaust ductwork.
exhaust system Yes No
Refer to Installation
restricted or Manual for exhaust
inadequate? system
requirements. Are there
Yes Repair/replace
holes in cabinets
cabinet
due to foreign
components.
No objects?

TMB1911S

24 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

11. Burner Not Burning Properly

Burner Not Burning


Properly

Is
Disassemble the airflow
Is there lint/dirt in Yes
burner and switch not Yes Replace airflow
burner tube?
blow out the dirt. functioning switch.
properly?

No No

Check serial
Is the gas plate on back of Is there
Yes Refer to Installation
pressure too high tumbler for inadequate Yes
Manual for make-up
or low? correct gas make-up
air requirements.
pressure. air?

No Tumbler is equipped
No
for the type of gas
specified on serial
Does
plate. If orifices are
the tumbler have Yes
different from that
incorrect
specified on serial Is there lint buildup Yes
orifices? Clean off lint.
plate, obtain and around gas valve
install correct spud?
orifices.
No

Is the
exhaust duct Yes Disassemble
restricted or and clean
blocked? exhaust system.

No

TMB1912S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 25


Troubleshooting

12. Loading Door Opens During Operation

Loading Door
Opens During
Operation

Is tumbler Yes Refer to Installation


improperly Manual for leveling
leveled? leg adjustment.

No

Is clothes Yes
load too Remove part of load
large? and restart tumbler.

No

Is loading Refer to
door strike Yes Adjustments
adjusted Section for strike
incorrectly? adjustment.

TMB1913S

26 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Troubleshooting

13. Cylinder Continues to Spin with Door Open

Cylinder
Continues To
Spin With Door
Open

Is relay Yes Replace relay


inoperative? in control box.

TMB1914S

NOTE: All tumbler panels must be in place and on the machine for
proper operation.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 27


Troubleshooting

14. Coin Does Not Fall into Coin Vault or Coin Drop Sensor Does Not Register
that Coin Has Been Entered

Coin Does Not Fall


Into Coin Vault or Coin
Drop Sensor Does Not
Register That Coin
Has Been Entered

Incorrect electrical
Is proper
connection may
electrical
No prevent coins from
power
registering in coin drop.
supplied to
Refer to wiring
coin drop?
diagram.

Yes Machines that are not


level may prevent coins
from following through
Is No required check stages
machine
of drop. Refer to
level?
Installation Manual
for instructions on
leveling machine.
Yes

Residue or lint build-up


may prevent coins from
Is coin No following through
drop
required check stages
clean?
of drop. Clean coin
drop.
Yes

Is sensor No Replace coin drop


operative? sensor.

TMB1915S

IMPORTANT: Never use oil to correct coin drop problem. Oil residue will prevent coins from rolling
properly.
IMPORTANT: Do not bend or damage mechanical parts within coin drop.

28 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Section 4
Adjustments
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

15. Loading Door Switch c. If switch actuator does not depress the switch
The door switch should be adjusted so the plunger enough to operate the switch, bend
cylinder stops when door is opened 2 inches (51 switch actuator OUTWARD and repeat steps
mm), plus or minus 1/4 inch (6 mm). The switch a and b..
is normally open and is closed when the door is
closed. If adjustment is needed, proceed as 16. Loading Door Strike
follows: Refer to Figure 1. Refer to Figure 1.
a. Close door and start tumbler. Slowly open The door strike must be adjusted so that sufficient
loading door. Cylinder and heat system should tension holds loading door closed against the
shut off when door is open 2 inches (51 mm), force of a load tumbling against it. The door is
plus or minus 1/4 inch (6 mm). properly adjusted when 8-15 lbs. (3.60-6.75 kg)
b. Slowly close loading door. When door is 2 of pull is required to open door.
inches or less from being fully closed, the
switch actuator on the door should contact the If adjustment is needed, follow these steps:
switch plunger and depress it enough to close a. Open loading door.
the switch with an audible click.
b. Loosen jamnut.
c. Turn door strike screw in or out as required.
d. Retighten jamnut.

Loading
Door

Switch
Actuator Jamnut
Door Strike
Screw T280SE3C

Figure 1

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 29


Section 5
Micro Display Control (MDC)
Troubleshooting
Models with BC, BL, BX and BY Control Suffixes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

17. Coins Ignored When Entered


Gas and electric heat.
Single and three phase
power supply.

Start coin drop


diagnostic tests.

YES Exit diagnostic


Does the display on the
testing and reset
electronic control
control. (Prompting
increment properly? for vend price)

NO

Is connector H2 on the NO Reconnect and run


control firmly seated in diagnostic test
its receptacle? again.

YES

Is the 3 pin connector NO Reconnect and run


between coin drop and diagnostic test
control connected again.
correctly?

YES

Are wires exiting coin YES


Replace coin drop
drop optical sensor
or optic switch.
cracked or broken?

NO

Replace coin drop.


If problem still exists TMB1978S
then replace the
electronic control.

30 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

18. Control Has No Display


Control has no display
Gas, steam and electric heat.
Single and three phase power supply.
(1) (6)

YES NO Correct wiring


Is there voltage across Is there voltage at
Replace electronic between secondary
H1-1 & H1-3 on the input of the
control. fuse and
the control? secondary fuse?
transformer.

NO YES

(7)

NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?

YES YES

(2)
Correct wiring
between control and
NO Correct wiring secondary fuse.
Is there voltage at input between primary
of primary fuses? fuse and power
supply.

YES

(3)

Is there voltage at NO
Replace primary
output side of the
fuse(s).
primary fuses?

YES

(4)

NO Correct wiring
Is there voltage across
between primary
terminals 1 & 2 of
fuse and
transformer primary?
transformer.

YES

(5)

Is there voltage across NO


Replace
terminals 1 &
transformer.
4 of transformer
secondary?

YES
TMB1979S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 31


32
TB1
L1

SERVICE

CONNECTION 2
L2

BLK
PRIMARY
FUSE
AGC-2A

LT. BLU
250V

BLK
1 2
5 1
120V
025 & 030 MODELS 035 & 055 MODELS
THERMISTOR THERMISTOR
4 WHT WHT WHT WHT
24V 24V WHT/BLU
3.5A 1.5A WHT
RED BLK BLK
2 3 1 4

H4 H4 10 9 8 7 6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
MDC CONTROL

H1-1
H1-3

RED
GRN/YEL
Micro Display Control (MDC) Troubleshooting

RED
6 WHT VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
SECONDARY 24Vac - WIRE JUMPER POWER HEAT RELAY
SECONDARY 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
FUSE 240Vac - 13.6K ohm 10 watt
FUSE
MDL-3.5A
1.25 T
DOOR SENSING CIRCUIT ALLOWS

24Vac Ret
250V

24VAC
250V CONTROL TO TURN ON MOTOR H2-6

RED/BLK
RELAY ONLY WHEN DOOR IS Door Sense Ret
7 CLOSED & SWITCH IS PRESSED

RED
H2-2

RED
H2-3
WHT

RED/BLU H2-1 H2-4


RED/BLK BRN/RED

MOTOR RELAY
LINT N.C.
FS-1
DOOR ORG/BRN

RED/WHT
PANEL
SWITCH COM
SWITCH
Control Has No Display

FS-2 START PULSE INPUT N.O.


RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW
N.O. COM N.O. COM Iin= 3-30ma SWITCH
HEAT RELAY TIME 20msec MIN.
H11L1

AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25

24Vac
Vmax=28Vdc
24Vac Ret

Imax=5ma
WHT/VLT

COIN DROPS 100 OHM


1/4 watt
H5 H6 H3
H1-2
H1-4

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT


3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1

CABINET
LIMIT
SEE VEND THERMOSTAT
APPLICATION DETAIL

TMB2213S

70380601
Micro Display Control (MDC) Troubleshooting

19. Door Open Indicator


Gas, steam and electric heat. Reference voltage
Single and three phase checks to transformer
(1) neutral. (6)

YES NO Correct wiring


Is there voltage at Is there voltage at
between secondary
H2-1 on the Electronic Replace Control. the input of the
fuse and
control? secondary fuse?
transformer.

NO YES

(7)

NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?

YES YES

(2) (8)

NO Correct wiring NO Correct wiring


Is there voltage at
Is there voltage at input between primary between N.O. and
N.O. of door
of primary fuses? fuses and power output of secondary
switch?
supply. fuse.

YES YES

(3) (9)

NO NO Check for proper


Is there voltage at With door closed is
Replace primary function of door
output side of the there voltage to
fuse(s). switch replace if
primary fuses? COM of door
necessary.
switch?

YES YES

(4) (10)

NO Correct wiring NO Correct wiring


Is there voltage across Is there voltage at
between primary between N.O. on lint
terminals 1 & 2 of N.O. of lint panel
fuses and panel and COM on
transformer primary? switch?
transformer. door switch.

YES YES

(5) (11)

Is there voltage across NO Is there voltage at NO Check for proper


Replace COM of lint panel
terminals 2 & 3 of operation replace if
transformer. switch with lint
transformer necessary.
secondary? panel closed?

YES YES

Correct wiring
between H2-1 of
electronic control
and COM of lint
panel switch.
TMB2039S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 33


34
TB1
L1

SERVICE

CONNECTION 2 5
L2
3
4

BLK
PRIMARY
FUSE
AGC-2A

LT. BLU
250V

BLK
1 2
1
120V
025 & 030 MODELS 035 & 055 MODELS THERMISTOR
THERMISTOR
WHT WHT
24V 24V WHT/BLU WHT WHT
WHT
3.5A 1.5A BLK
RED BLK
2 3 1 4

H4 H4 10 9 8 7 6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
MDC CONTROL

H1-1
H1-3
6

RED
GRN/YEL

RED
WHT VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
Micro Display Control (MDC) Troubleshooting

H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS


SECONDARY 24Vac - WIRE JUMPER POWER HEAT RELAY
SECONDARY 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
FUSE 240Vac - 13.6K ohm 10 watt
FUSE
MDL-3.5A
1.25 T
DOOR SENSING CIRCUIT ALLOWS

24Vac Ret
250V

24VAC
250V CONTROL TO TURN ON MOTOR H2-6

RED/BLK
7 RELAY ONLY WHEN DOOR IS Door Sense Ret
CLOSED & SWITCH IS PRESSED

RED
H2-2

RED
H2-3
9 10 WHT
11
8 RED/BLU H2-1 H2-4
RED/BLK BRN/RED

MOTOR RELAY
LINT N.C.
FS-1
DOOR ORG/BRN

RED/WHT
PANEL
Door Open Indicator

SWITCH COM
SWITCH
FS-2 START PULSE INPUT N.O.
RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW
N.O. COM N.O. COM Iin= 3-30ma SWITCH
HEAT RELAY TIME 20msec MIN.
H11L1

AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING
4N25

24Vac
Vmax=28Vdc
24Vac Ret

Imax=5ma
WHT/VLT

COIN DROPS 100 OHM


1/4 watt
H5 H6 H3
H1-2
H1-4

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT


3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1

CABINET
LIMIT
SEE VEND THERMOSTAT
APPLICATION DETAIL

TMB2214S

70380601
Micro Display Control (MDC) Troubleshooting

20. Motor Will Not Start/Run


Note: test conducted with vend Gas, electric and steam heat.
(1) price satisfied and start button Single and three phase power supply.
pressed.

Is there voltage across NO Refer to Door Replace MDC


H2-1 and H2-6 on Open Indicator control.
the electronic control ? flowchart. (6)

NO Correct wiring
Is there voltage across
YES between fan motor
terminals 1 & 4 of
and motor control
(2) the fan motor?
relay.

Is there voltage NO
across H2-4 and H2-6 Replace
YES
on the electronic control? control.

NO
Does the fan motor
YES Replace fan motor.
run?
(3)

Is there voltage NO
across the coil of Correct wiring to coil
YES
the motor control of motor relay .
relay?

Is unit equipped with Single phase


YES single phase or three
phase power supply?
3 phase. Also
see Note on
next page
Is the unit equipped Three phase. Also
with single phase or see Note on next
three phase power? (12) page.

Is there supply voltage NO Correct wiring


Single phase between L2 & L3 of between L2, L3 and
(4) motor control relay? supply.

Is there voltage at NO Correct wiring


terminal 5 of the between terminal 5 YES
motor control relay? and power supply. (13)

Is there voltage across YES


Replace motor
YES terminals L2 & T2 and
control relay.
(5) L3 & T3?

Is there voltage at NO
Replace motor
terminal 8 of motor NO
control relay.
control relay?
(7)

YES Correct wiring


Is there voltage at NO
between terminal 6
(10) terminal 6 of motor
of motor control
control relay?
relay and supply.

Is there supply voltage NO Correct wiring


to L1 and L2 of the between L1, L2 and
motor control relay? power supply. YES
(8)

YES Is there voltage at NO


Replace motor
(11) terminal 9 of motor
control relay.
control relay?

YES
Is there votlage across Replace motor
L1 & T1 and L2 & T2? control relay.
YES

NO
TMB1982S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 35


Micro Display Control (MDC) Troubleshooting

20. Motor Will Not Start/Run (continued)


(9)

NO Correct wiring
Is there voltage across
between cylinder
terminals 1 & 4 of
motor and motor
cylinder motor?
control relay.

YES

NO
Does the cylinder Replace cylinder
motor run? motor.

YES

Motors are
operational.

Note: For high voltage three phase supply (380 volts


or higher), the cylinder and fan motors are supplied
by L1, L2, L3 through the motor relay terminals T1,
T2, T3. Make the appropriate adjustments when
doing voltage checks.

TMB1982S

TMB1982S

Please see following 2 pages for wiring diagram information.

36 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


70380601
7
4
TB1-L1

TB1-N
120V
SERVICE

TB1-L2

208-240V
SERVICE
BLK/RED

BLK
5
LT. BLU

5 6 BLK/RED

8
M M
1
025 & 030 MODELS 035 & 055 MODELS
THERMISTOR THERMISTOR 8
FAN 9
CYLINDER
WHT WHT WHT WHT
MOTOR MOTOR
WHT/BLU
5
WHT 3
RED BLK BLK
GRY/BLK
BLU/BLK

RUN RUN
1 1
H4 10 9 8 7 6 5 4 3 2 1 H4 10 9 8 7 6 5 4 3 2 1
MDC CONTROL

H1-1
H1-3
GRN/YEL AUX AUX
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
MAIN 2 4 MAIN 2 4
24Vac - WIRE JUMPER POWER HEAT RELAY THERM THERM
120Vac - 6.8K ohm 5 watt SUPPLY PROT. PROT.
CHASSIS GROUND
240Vac - 13.6K ohm 10 watt

DOOR SENSING CIRCUIT ALLOWS MAIN 1 MAIN 1

24Vac Ret

24VAC
CONTROL TO TURN ON MOTOR H2-6
WHT

RED/BLK
RELAY ONLY WHEN DOOR IS Door Sense Ret
CLOSED & SWITCH IS PRESSED
H2-2 2 3
H2-3
WHT

B A 6 9
H2-4
RED/BLK BRN/RED M WHT
H2-1
MOTOR RELAY M
N.C.
FS-1 ORG/
ORG/BRN ORG BRN WHT/
WHT BRN
COM 7 4 3 5
FS-2 START PULSE INPUT N.O.
RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
Iin= 3-30ma SWITCH CENTRIFUGAL
TIME 20msec MIN. SWITCH
HEAT RELAY
BRN/WHT

H11L1
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING

4N25

24Vac
Vmax=28Vdc

24Vac Ret
Imax=5ma
Motor Will Not Start/Run (Sheet 1 of 2)

IGN
WHT/VLT
COIN DROPS 100 OHM
WHT

1/4 watt
H5 H6 H3

H1-2
H1-4
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1
TH GND
VLT VLT/WHT 3

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT


2
GND WHT
3
CABINET STOVE GAS VALVE
LIMIT LIMIT ICM
SEE VEND THERMOSTAT THERMOSTAT FIRST COIL
APPLICATION DETAIL
GND VALV
GRN/YEL
SECOND COIL
WHT/
4 1 BLK

TMB2215S
Micro Display Control (MDC) Troubleshooting

37
38
TB1-L1

TB1-L1

TB1-L2

TB1-L2

TB1-L3
TB1-L3

L2 L3

BLK
WHT
BLK/
BLK
BLK/RED
PRIMARY 10 12

BLK/WHT
HC2 HC1
FUSES
AGC-2A L1 L2 L3

T2 T3 250V
M M M 13

BLK
WHT
BLK/
H3 1 2
11
T1 T2 T3
SEE
TRANSFORMER 1
CONFIGURATION
JUMPER
1 2 3 4 5 6 025 & 030 MODELS 035 & 055 MODELS 5
3
THERMISTOR THERMISTOR
GRY/BLK
BLU/BLK

H5 RUN RUN
LT. BLU
LT. BLU

1 1
WHT/BLU WHT WHT WHT WHT
WHT
RED BLK BLK AUX AUX
24V 24V
4.0A 1.5A MAIN 2 4 MAIN 2 4
H4 H4 THERM THERM
10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
MDC CONTROL PROT. PROT.

H1-1
2 3 1 4

H1-3
GRN/YEL
Micro Display Control (MDC) Troubleshooting

RED
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS MAIN 1 MAIN 1

RED
24Vac - WIRE JUMPER POWER HEAT RELAY
WHT 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
SECONDARY 2 FAN CYLINDER
DOOR SENSING CIRCUIT ALLOWS

24Vac Ret
FUSE

24VAC
SECONDARY CONTROL TO TURN ON MOTOR H2-6 MOTOR
MDL-3.5A WHT MOTOR

RED/BLK
FUSE RELAY ONLY WHEN DOOR IS Door Sense Ret
250V 1.25 T CLOSED & SWITCH IS PRESSED
H2-2
250V H2-3
WHT

RED

RED
3
RED/BLU H2-1 H2-4
RED/BLK BRN/RED M WHT 6 9
MOTOR RELAY M
LINT N.C.
FS-1 ORG/
DOOR ORG/BRN ORG BRN WHT/
WHT BRN

RED/WHT
PANEL 3 5
SWITCH COM 14 13
SWITCH
FS-2 START PULSE INPUT N.O.
RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
N.O. COM N.O. COM Iin= 3-30ma SWITCH CENTRIFUGAL
TIME 20msec MIN. SWITCH
HEAT RELAY
BRN/WHT

H11L1
WHT

AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING

4N25

24Vac
Vmax=28Vdc

24Vac Ret
Imax=5ma
WHT/VLT

COIN DROPS 100 OHM


1/4 watt
HC1
H5 H6 H3

H1-2
H1-4
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1
Motor Will Not Start (Sheet 2 of 2)

VLT VLT/WHT

CABINET STOVE HC2


LIMIT LIMIT
SEE VEND THERMOSTAT THERMOSTAT
APPLICATION DETAIL

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT


TMB2216S

70380601
Micro Display Control (MDC) Troubleshooting

21. Unit Will Not Heat Gas


Note: Tests are conducted with unit running
and calling for heat.
All voltage checks are referenced to
transformer neutral.
(1) (7)

Correct wiring
NO Correct wiring Is there voltage at NO between terminal 3
Is there voltage at terminal 3 of fan of fan motor
between FS-2 and
FS-2 of MDC control? motor centrifugal centrifugal switch
COM of lint drawer.
switch? and terminal 4 of
motor control relay.

YES YES
Replace Replace MDC
thermistor. control.
(2) (8)

Is there voltage NO NO Is there voltage across YES


at FS-1 of MDC terminals 3 & 5 of fan motor Replace fan motor.
control? centrifugal switch?

Is the
YES
thermistor
operational?
YES NO

(3) (9)

Correct wiring Correct wiring


NO between COM of Is there voltage to the NO between cabinet
Is there voltage at COM
of airflow switch? airflow switch and input side of the limit and terminal 5
FS-1 of MDC cabinet limit? of fan motor
control. centrifugal switch.

YES YES

(4) (10)

YES Check for proper YES


Is there voltage across
function of airflow Is there voltage across Replace cabinet
COM & N.C. terminal
switch and replace if cabinet limit? limit.
of airflow switch?
necessary.

NO NO

(5) (11)

Correct wiring
Is there voltage at NO between terminal 7 NO Correct wiring
on motor control Is there voltage to the
terminal 7 of motor input side of the stove between stove limit 1
control relay? relay and N.C. and cabinet limit.
terminal on airflow limit?
switch.

YES YES

(6)

Is there voltage across YES


Replace motor
terminals 7 & 4 of
control relay.
motor control relay?

NO
TMB1985S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 39


Micro Display Control (MDC) Troubleshooting

21. Unit Will Not Heat Gas (continued)

(12)

YES YES NO Replace gas valve


Is there voltage across Replace the stove Is there gas flow
through the gas valve? coils or complete
the stove limit 1? limit.
gas valve.

NO YES

(13)

Is there voltage to NO Correct wiring NO Replace high


input side of between stove limit 1 Does the igniter spark? voltage ignition
stove limit 2? and stove limit 2. cable or igniter.

YES YES

(14)

Is there voltage YES YES


across stove limit 2? Replace stove limit 2. Is there a flame? Unit operational.

NO

NO
(15)

Is there voltage to Correct wiring


NO
terminal 2 of between terminal 2
the Ignition Control of ICM and stove
Module (ICM)? limit 2.

YES
Note: Make sure unit is
not in a lock out
(16) condition.

Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?

YES

(17)

NO Correct wiring
Is there voltage across
between gas valve
the coils of the gas
and ICM board.
valve?

YES

TMB1985S

Please see following page for wiring diagram information.

40 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

Unit Will Not Heat Gas

TMB2217S
16

17
9
7

8
6

14
5

15
4

10
3
1

13
12

11
2

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 41


Micro Display Control (MDC) Troubleshooting

22. Unit Will Not Heat Steam


Note: Tests are conducted with unit running
and calling for heat.

All voltage checks are referenced to


transformer neutral.

(1) (7)

Correct wiring
NO Is there voltage on NO between terminal 3
Correct wiring
Is there voltage on terminal 3 of fan of fan motor
between FS-2 and
FS-2 of MDC control? motor centrifugal switch? centrifugal switch
COM of lint panel.
and terminal 4 of
motor control relay.

YES
Replace MDC YES
Replace
control.
thermistor.
(2) (8)

Is there voltage NO NO Is there voltage across


YES
on FS-1 of terminals 3 & 5 of Replace fan motor.
MDC control? fan motor centrifugal switch?

Is the YES
thermistor
YES operational?
NO

(3) (9)

Correct wiring Correct wiring


Is there voltage on NO between COM of Is there voltage to the NO between cabinet
COM of airflow airflow switch and input side of the limit and terminal 5
switch? FS-1 of MDC cabinet limit? of fan motor
control. centrifugal switch.

YES YES

(4) (10)

YES Check for proper YES


Is there voltage across function of airflow Is there voltage across Replace cabinet
COM & N.C. terminal switch and replace if cabinet limit? limit.
of airflow switch? necessary.

NO NO

(5) (11)

Correct wiring
NO between terminal 7 NO
Is there voltage on Is there voltage to the Correct wiring
on motor control
terminal 7 of motor input side of the stove between stove limit
relay and N.C.
control relay? limit? and cabinet limit.
terminal on airflow
switch.

YES
YES

(6)

Is there voltage across YES


Replace motor
terminals 7 & 4 of
control relay.
motor control relay?

NO TMB2040S

42 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

22. Unit Will Not Heat Steam (continued)

(12)

Correct wiring YES


Is there voltage across Replace the stove
between terminal 3 the stove limit? limit.
of fan motor
centrifugal switch
and terminal 4 of
motor control relay.

NO

(13)

NO Correct wiring
Is there voltage across between steam
the coil of the steam valve? valve and stove
Replace fan motor. limit.

YES

No
Correct wiring Does the steam valve Replace or rebuild
between cabinet open allowing steam to flow? steam valve.
limit and terminal 5
of fan motor
centrifugal switch.

Unit operational.

Replace cabinet
limit.

Correct wiring
between stove limit
and cabinet limit.

TMB2040S

Please see following page for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 43


44
1

025 & 030 MODELS 035 & 055 MODELS


THERMISTOR THERMISTOR

WHT/BLU WHT WHT WHT WHT


WHT
RED BLK BLK

H4 10 9 8 7 6 5 4 3 2 1 H4 10 9 8 7 6 5 4 3 2 1
MDC CONTROL

H1-1
H1-3
GRN/YEL
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS
24Vac - WIRE JUMPER POWER HEAT RELAY
120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
7
DOOR SENSING CIRCUIT ALLOWS

24Vac Ret

24VAC
CONTROL TO TURN ON MOTOR H2-6
WHT

RED/BLK
RELAY ONLY WHEN DOOR IS Door Sense Ret
CLOSED & SWITCH IS PRESSED
H2-2
H2-3
2 WHT 5
Micro Display Control (MDC) Troubleshooting

4 B A
6 8
H2-1 H2-4
RED/BLK 3 BRN/RED M WHT

MOTOR RELAY M
N.C.
FS-1 ORG/
ORG/BRN ORG BRN WHT/
WHT BRN
COM 7 4 3 5
FS-2 START PULSE INPUT N.O.
RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
Iin= 3-30ma SWITCH CENTRIFUGAL
TIME 20msec MIN. SWITCH
HEAT RELAY
H11L1 BRN/WHT
AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN
MACHINE RUNNING

4N25
13

24Vac
Unit Will Not Heat Steam

Vmax=28Vdc

24Vac Ret
Imax=5ma 10 12
WHT/VLT

COIN DROPS 100 OHM


WHT

1/4 watt STEAM


H5 H6 H3

H1-2
H1-4
3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1 VALVE

VLT VLT/WHT WHT/BLK

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT


CABINET STOVE
LIMIT LIMIT
SEE VEND THERMOSTAT THERMOSTAT
APPLICATION DETAIL

9
11
TMB2218S

70380601
Micro Display Control (MDC) Troubleshooting

23. Unit Will Not Heat Electric


Note: Tests are conducted with unit running
and calling for heat.

All voltage checks are referenced to


transformer neutral.

(1)
(7)

Correct wiring
NO Correct wiring Is there voltage at NO between terminal 3
Is there voltage at between FS-2 and terminal 3 of fan of fan motor
FS-2 of MDC control? COM of lint panel motor centrifugal centrifugal switch
switch. switch? and terminal 13 of
motor control relay.

YES YES
Replace Replace MDC
thermistor. control.
(2) (8)

NO NO Is there voltage across YES


Is there voltage
terminals 3 & 5 of
on FS-1 of Replace fan motor.
fan motor centrifugal switch?
MDC control?

Is the YES
thermistor
YES operational?
NO

(3) (9)

Correct wiring Correct wiring


NO between COM of Is there voltage to the NO between cabinet
Is there voltage at COM
airflow switch and input side of the limit and terminal 5
of airflow switch?
FS-1 of MDC cabinet limit? of fan motor
control. centrifugal switch.

YES YES

(4) (10)

YES Check for proper YES


Is there voltage across
function of airflow Is there voltage across Replace cabinet
COM & N.C. terminal
switch and replace if cabinet limit? limit.
of airflow switch?
necessary.

NO NO

(5) (11)

Correct wiring
NO between terminal 7 NO
Is there voltage at Is there voltage to the Correct wiring
on motor control
terminal 14 of motor input side of the stove between stove limit
relay and N.C.
control relay? limit? and cabinet limit.
terminal on airflow
switch.

YES YES

(6)

Is there voltage across YES


Replace motor
terminals 13 & 14 of
control relay.
motor control relay?

TMB2041S
NO

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 45


Micro Display Control (MDC) Troubleshooting

23. Unit Will Not Heat Electric (continued)


Note: Please make
the oppropriate
adjustments if your
(12)
unit is single phase.

YES
Is there voltage across Replace the stove
the stove limit? limit.

NO

(13)

NO Correct wiring
Is there voltage across
between heater
the coil(s) of the heater
contactor and stove
contactor(s)?
limit.

YES

(14)

Is there voltage to the NO Correct wiring


L1, L2 and L3 between HC1 and
terminals of HC1? line voltage.

YES

(15)

Is there voltage to the NO Correct wiring


L1, L2 and L3 between HC2 and
terminals of HC2? line voltage.

YES

(16)(17)(18)

NO Check for
Is there voltage across
proper operation of
T1 & T2, T2 & T3 and
contactors, replace
T3 & T1?
them if necessary.

Unit is operational
YES

Check elements for


NO shorts or opens.
Do all elements
Check wires
produce heat?
between contactors
and elements.

YES

TMB2041S

Please see following page for wiring diagram information.

46 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


70380601
14
TB1-L1
TB3
L1

SERVICE TB1-L2

L2

CONNECTION
TB1-L3
L3

L3 L1 L1 L2 L2 L3

BLK
WHT
BLK/
HC2 HC1 HC2 HC1 HC2 HC1 PRIMARY
FUSES
AGC-2A
T3 T1 T1 T2 T2 T3 250V

BLK
WHT
BLK/
H1 H2 H3 1 2

SEE
TRANSFORMER 1
CONFIGURATION
JUMPER
16
1 2 3 4 5 6 025 & 030 MODELS 035 & 055 MODELS
THERMISTOR THERMISTOR
H6 H4 H5
WHT/BLU WHT WHT WHT WHT
WHT
RED BLK BLK

HEATING ELEMENTS 24V 24V


4.0A 1.5A H4 H4
10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
MDC CONTROL

H1-1
2 3 1 4

H1-3
17 18 GRN/YEL

RED
VOLTAGE CONFIGURATION INPUT TEMP. REGULATING
15 H2-5 JUMPER H2-2 TO H2-5 AS FOLLOWS: CONTROL CIRCUIT CONTROLS

RED
24Vac - WIRE JUMPER POWER HEAT RELAY
WHT 120Vac - 6.8K ohm 5 watt SUPPLY CHASSIS GROUND
240Vac - 13.6K ohm 10 watt
SECONDARY 7
DOOR SENSING CIRCUIT ALLOWS

24Vac Ret
FUSE

24VAC
SECONDARY CONTROL TO TURN ON MOTOR H2-6
MDL-3.5A WHT

RED/BLK
FUSE RELAY ONLY WHEN DOOR IS Door Sense Ret
250V 1.25 T CLOSED & SWITCH IS PRESSED
H2-2
250V H2-3
2 WHT 5

RED

RED
4 6 8
RED/BLU H2-1 H2-4
RED/BLK 3 BRN/RED M WHT

MOTOR RELAY M
LINT N.C.
FS-1 ORG/
DOOR ORG/BRN ORG BRN WHT/
WHT BRN

RED/WHT
PANEL 3 5
SWITCH COM 14 13
SWITCH
FS-2 START PULSE INPUT N.O.
RED/WHT RED/BLK H3-1 & H3-2 AIR FLOW FAN MOTOR
N.O. COM N.O. COM Iin= 3-30ma SWITCH CENTRIFUGAL
Unit Will Not Heat Electric

TIME 20msec MIN. SWITCH


HEAT RELAY
BRN/WHT
H11L1
WHT

AVAILABLE OUTPUT
H3-3 & H3-4
OPTO OFF WHEN 13
MACHINE RUNNING
4N25

24Vac

Vmax=28Vdc
24Vac Ret

Imax=5ma 10 12
WHT/VLT

COIN DROPS 100 OHM


1/4 watt
HC1
H5 H6 H3
H1-2
H1-4

3 2 1 5 4 6 8 7 9 10 11 12 1 2 3 4 5 6 7 6 5 4 3 2 1

VLT VLT/WHT

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT


CABINET STOVE HC2
LIMIT LIMIT
SEE VEND THERMOSTAT THERMOSTAT
APPLICATION DETAIL

9
11

TMB2219S
Micro Display Control (MDC) Troubleshooting

47
Micro Display Control (MDC) Troubleshooting

WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1

24. Error Codes


OP - Indicates physical open in the thermistor Card Reader Machines: (In addition to the
circuit. Possible causes are: 1) thermistor, 2) above errors)
wiring between control and thermistor, 3) control.
EC:19 - Indicates no card reader communication.
SH - Indicates a short in the thermistor circuit. The control and the reader cannot communicate.
Possible causes are: 1) shorted thermistor, 2) a Check reader, control and harness.
short in the wiring between control and
thermistor, 3) control. NOTE: For all other card reader errors, consult
the card reader manual provided by the
manufacturer.

Display Definition Corrective Action


OP Indicates an open circuit in the thermistor. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
SH Indicates a short circuit in the thermistor. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
EC:19 Indicates no communication between Check card reader. Replace if inoperative.
control and card reader. Check wire harness connecting card reader
*Card Reader and control. Replace if inoperative.
models only Check control. Replace if inoperative.

48 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

TMB2241S

Gas and Steam Models


Control Circuit Schematic

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 49


Micro Display Control (MDC) Troubleshooting

TMB2221S

Gas and Steam Models


Control Circuit Connection

50 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

TMB2027S

Gas and Steam Models


Control Box Schematic

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 51


Micro Display Control (MDC) Troubleshooting

TMB2026S

Gas and Steam Models


Control Box Connection

52 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

TMB2222S

Gas and Steam Models


Control Circuit Schematic

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 53


Micro Display Control (MDC) Troubleshooting

TMB2223S

Gas and Steam Models


Control Circuit Schematic

54 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

TMB2027S

Gas and Steam Models


Control Box Schematic

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 55


Micro Display Control (MDC) Troubleshooting

TMB2026S

Gas and Steam Models


Control Box Connection

56 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

TMB2220S

Electric Models
Control Circuit Schematic

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 57


Micro Display Control (MDC) Troubleshooting

TMB2224S

Electric Models
Control Circuit Connection

58 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Micro Display Control (MDC) Troubleshooting

TMB2030S

Electric Models
Control Box Connection

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 59


Micro Display Control (MDC) Troubleshooting

TMB2031S

Electric Models
Control Box Schematic

60 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Section 6
NetMaster Troubleshooting
Models with NC, NR, NX, NY, ZC, ZR, ZX and ZY
Control Suffixes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

25. No Infra-red (IR) Communication


Gas and electric heat.
Attempt to Single and three phase
communicate with power supply.
the electronic
control from
the handheld
communication
device

Check the following:


- low battery in handheld
communication device.
Aim handheld - low battery in the Symbol SPT 1800
Is there a response of NO NO
communication Does the control infra-red box.
any kind from the
device closer and respond? - poor connection between IR cup and
electronic control?
try again. Micro-Wand.
- poor connection between IR box and
Symbol SPT 1800.
- is the IR window covered or blurred
YES YES on the control.

NO

Does the electronic -C- Communication Replace the


control display E:OF sequence checks electronic control.
or -C-? out.

"E:OF"

Check the following:

- IR communication disabled by
manual programming.
- Is the IR window on the control
covered or blocked.
- if needed, change control
board.
TMB1991S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 61


NetMaster Troubleshooting

26. Coins Ignored When Entered


Gas and electric heat.
Single and three phase
power supply.

Start coin drop


diagnostic tests.

YES Exit diagnostic


Does the display on the
testing and reset
electronic control
control. (Prompting
increment properly? for vend price)

NO

Is connector H5 on the NO Reconnect and run


control firmly seated in diagnostic test
its receptacle? again.

YES

Is the 3 pin connector NO Reconnect and run


between coin drop and diagnostic test
control connected again.
correctly?

YES

Are wires exiting coin YES


drop optical sensor Replace coin drop
cracked or broken? or optic switch.

NO

Replace coin drop.


If problem still exists TMB1992S
then replace the
electronic control.

62 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


NetMaster Troubleshooting

27. Control Has No Display


Gas, steam and electric heat.
(1) Single and three phase (6)
power supply.

YES NO Correct wiring


Is there voltage across Is there voltage at
Replace electronic between secondary
H1-1 & H1-3 on the input of the
control. fuse and
the control? secondary fuse?
transformer.

NO YES

(7)

NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?

YES YES

(2)
Correct wiring
between control and
NO Correct wiring secondary fuse.
Is there voltage at input between primary
of primary fuses? fuse and power
supply.

YES

(3)

Is there voltage at NO
Replace primary
output side of the
fuse(s).
primary fuses?

YES

(4)

NO Correct wiring
Is there voltage across
between primary
terminals 1 & 2 of
fuse and
transformer primary?
transformer.

YES

(5)

Is there voltage across NO


Replace
terminals 1 &
transformer.
4 of transformer
secondary?

YES
TMB1993S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 63


NetMaster Troubleshooting

Control Has No Display

TMB2225S
1
5
3
2

7
6
4

64 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


NetMaster Troubleshooting

28. Door Open Indicator


Gas, steam and electric heat. Reference voltage
Single and three phase supply. checks to transformer
(1) neutral. (6)

YES NO Correct wiring


Is there voltage at Is there voltage at
between secondary
H2-1 on the electronic Replace control. the input of the
fuse and
control? secondary fuse?
transformer.

NO YES

(7)

NO Is there voltage at NO
Is there power supplied Plug unit in and run Replace secondary
output side of
to the unit? it. fuse.
secondary fuse?

YES YES

(2) (8)

NO Correct wiring NO Correct wiring


Is there voltage at
Is there voltage at input between primary between N.O. and
N.O. of door
of primary fuses? fuses and power output of secondary
switch?
supply. fuse.

YES YES

(3) (9)

NO NO Check for proper


Is there voltage at With door closed is
Replace primary function of door
output side of the there voltage to
fuse(s). switch replace if
primary fuses? COM of door
necessary.
switch?

YES YES

(4) (10)

NO Correct wiring NO Correct wiring


Is there voltage across Is there voltage at
between primary between N.O. on lint
terminals 1 & 2 of N.O. of lint panel
fuses and panel and COM on
transformer primary? switch?
transformer. door switch.

YES YES

(5) (11)

Is there voltage across NO Is there voltage at NO Check for proper


Replace COM of lint panel
terminals 2 & 3 of operation replace if
transformer. switch with lint
transformer necessary.
secondary? panel closed?

YES YES

Correct wiring
between H2-1 of
electronic control
and COM of lint
panel switch.
TMB2042S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 65


NetMaster Troubleshooting

Door Open Indicator

TMB2226S
1

11
4

5
3

10
9
2

8
6

66 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


NetMaster Troubleshooting

29. Motor Will Not Start/Run


Note: test conducted with vend Gas, electric and steam heat.
(1) price satisfied and start button Single and three phase supply.
pressed.

Is there voltage across NO Refer to Door


Replace electronic
H2-1 and H2-6 on Open Indicator
control.
the electronic control ? flowchart. (6)

NO Correct wiring
Is there voltage across
YES between fan motor
terminals 1 & 4 of
and motor control
(2) the fan motor?
relay.

Is there voltage NO
across H2-4 and H2-6 Replace
YES
on the electronic control? control.

NO
Does the fan motor
YES Replace fan motor.
run?
(3)

Is there voltage NO
across the coil of Correct wiring to coil
YES
the motor control of motor relay .
relay?

Is unit equipped with Single phase


YES single phase or three
phase power supply?
3 phase. Also
see note on
next page
Is the unit equipped Three phase. Also
with single phase or see Note on next
three phase power? (12) page.

Is there supply voltage NO Correct wiring


Single phase between L2 & L3 of between L2, L3 and
(4) motor control relay? supply.

Is there voltage at NO Correct wiring


terminal 5 of the between terminal 5 YES
motor control relay? and power supply. (13)

Is there voltage across YES


Replace motor
YES terminals L2 & T2 and
control relay.
(5) L3 & T3?

Is there voltage at NO
Replace motor
terminal 8 of motor NO
control relay.
control relay?
(7)

YES Correct wiring


Is there voltage at NO
between terminal 6
(10) terminal 6 of motor
of motor control
control relay?
relay and supply.

Is there supply voltage NO Correct wiring


to L1 and L2 of the between L1, L2 and
motor control relay? power supply. YES
(8)

YES Is there voltage at NO


Replace motor
(11) terminal 9 of motor
control relay.
control relay?

YES
Is there votlage across Replace motor
L1 & T1 and L2 & T2? control relay.
YES

NO

Note: tests conducted with vend TMB2043S


price satisfied and start button
pressed.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 67


NetMaster Troubleshooting

29. Motor Will Not Start/Run (continued)


(9)

NO Correct wiring
Is there voltage across
between cylinder
terminals 1 & 4 of
motor and motor
cylinder motor?
control relay.

YES

NO
Does the cylinder Replace cylinder
motor run? motor.

YES

Motors are
operational.

Note: For high voltage three phase supply (380 volts


or higher), the cylinder and fan motors are supplied
by L1, L2, L3 through the motor relay terminals T1,
T2, T3. Make the appropriate adjustments when
doing voltage checks.

TMB2043S
TMB2043S

Please see following 2 pages for wiring diagram information.

68 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Motor Will Not Start/Run
1 Phase Models

TMB2227S
9
7

6
5
4

3
2
1

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 69


NetMaster Troubleshooting

Motor Will Not Start


3 Phase Models

TMB2228S
9
12

13

6
10

11

3
2
1

70 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


NetMaster Troubleshooting

30. Unit Will Not Heat Gas

Note: Tests are conducted with unit running


and calling for heat.

All voltage checks are referenced to


transformer neutral.

(1) (7)

Correct wiring
NO Is there voltage at NO between terminal 3
Correct wiring
Is there voltage at terminal 3 of fan of fan motor
between FS-2 and
FS-2 of the control? motor centrifugal centrifugal switch
COM of lint panel.
switch? and terminal 4 of
motor control relay.

YES YES
Replace Replace the
thermistor. control.
(2) (8)

Is there voltage NO NO Is there voltage across YES


at FS-1 of the terminals 3 & 5 of fan motor Replace fan motor.
control? centrifugal switch?

Is the YES
thermistor
YES operational? NO

(3) (9)

Correct wiring Correct wiring


NO between COM of Is there voltage to the NO between cabinet
Is there voltage at COM
airflow switch and input side of the limit and terminal 5
of airflow switch?
FS-1 of the cabinet limit? of fan motor
control. centrifugal switch.

YES YES

(4) (10)

YES Check for proper YES


Is there voltage across
function of airflow Is there voltage across Replace cabinet
COM & N.O. terminal
switch and replace if cabinet limit? limit.
of airflow switch?
necessary.

NO NO

(5) (11)

Correct wiring
NO between terminal 7 NO
Is there voltage at Is there voltage to Correct wiring
on motor control
terminal 7 of motor the input side of between stove limit 1
relay and N.O.
control relay? stove limit 1? and cabinet limit.
terminal on airflow
switch.

YES YES

(6)

Is there voltage across YES


Replace motor
terminals 7 & 4 of TMB2231S
control relay.
motor control relay?

NO

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 71


NetMaster Troubleshooting

30. Unit Will Not Heat Gas (continued)

(12)

YES NO Replace gas valve


Is there voltage across Replace Is there gas flow
stove limit 1. coils or complete
stove limit 1? through the gas valve?
gas valve.

NO YES

(13)

NO Correct wiring to
Is there voltage to the NO Replace high
input side of
input side of the Does the igniter spark? voltage ignition
stove limit 2 and
stove limit 2? cable or igniter.
stove limit 1.

YES YES

(14)

Is there NO YES
Replace
voltage across stove limit 2. Is there a flame? Unit operational.
stove limit 2?

YES NO

(15)

Is there voltage to NO Correct wiring


terminal 2 of between terminal 2
the Ignition Control of ICM and stove
Module (ICM)? limit.

YES
Note: Make sure unit is
not in a lock out
(16) condition.

Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?

YES

(17)

Is there voltage across NO Correct wiring


the coils of the gas between gas valve
valve? and ICM board.

YES

TMB2231S
TMB2231S

Please see following page for wiring diagram information.

72 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


NetMaster Troubleshooting

Unit Will Not Heat Gas

TMB2229S
17
16
8
7

15
9
6

14

13
5

10
4

12
3
2

or
or

11
1

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 73


NetMaster Troubleshooting

31. Unit Will Not Heat Steam


Note: Tests are conducted with unit running
and calling for heat.

All voltage checks are referenced to


transformer neutral.

(1) (7)

Correct wiring
NO Is there voltage on NO between terminal 3
Correct wiring
Is there voltage on terminal 3 of fan of fan motor
between FS-2 and
FS-2 of electronic control? motor centrifugal switch? centrifugal switch
COM of lint panel.
and terminal 4 of
motor control relay.

YES YES
Replace electronic
Replace (8)
control.
thermistor.
(2)

Is there voltage across


YES
terminals 3 & 5 of Replace fan motor.
Is there voltage NO NO
fan motor centrifugal switch?
on FS-1 of
electronic
control?
Is the YES
thermistor NO
YES operational?
(9)

(3) Correct wiring


Is there voltage to the NO between cabinet
input side of the limit and terminal "5"
Correct wiring
cabinet limit? of fan motor
Is there voltage on NO between COM of
centrifugal switch.
COM of airflow airflow switch and
switch? FS-1 of electronic
control.
YES
(10)
YES

(4) YES
Is there voltage across Replace cabinet
cabinet limit? limit.

YES Check for proper


Is there voltage across
function of airflow
COM & N.C. terminal
switch and replace if
of airflow switch?
necessary.
NO

(11)
NO

NO Correct wiring
(5) Is there voltage across between steam
the coil of the steam valve? valve and stove
Correct wiring limit.
NO between terminal 7
Is there voltage on
on motor control
terminal 7 of motor
relay and N.C.
control relay? YES
terminal on airflow
switch.

YES
No
Does the steam valve Replace steam
open allowing steam to flow? valve.
(6)

Is there voltage across YES


Replace motor
terminals 7 & 4 of
control relay.
motor control relay?

Unit operational.
NO TMB2044S

74 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


NetMaster Troubleshooting

Unit Will Not Heat Steam

TMB2230S
11
8
7

6
5
4
3

10
2

9
1

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 75


Section 7
Hybrid Timer Control Troubleshooting
Models with QT, SD and SX Control Suffixes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

32. Coins Ignored When Entered


Gas and electric heat.
Single and three phase
power supply.

Start coin drop


diagnostic tests.

YES Exit diagnostic


Does the light
testing and reset
on the control
control. (Prompting
increment properly? for vend price)

NO

Is connector H2 on the NO Reconnect and run


control firmly seated in diagnostic test
its receptacle? again.

YES

Is the 3 pin connector NO Reconnect and run


between coin drop and diagnostic test
control connected again.
correctly?

YES

Are wires exiting coin YES


Replace coin drop
drop optical sensor
or optic switch.
cracked or broken?

NO

Replace coin drop.


If problem still exists TMB2051S
then replace the
electronic control. TMB2051S

76 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

33. Control Has No Display OPL Models


Gas, steam and electric heat.
Single and three phase supply.
(6)

Is there voltage NO Connect supply Check H6-1 (+) and NO Replace hybrid
supplied to the unit? voltage and run unit. H6-2 (-) for +5 VDC. control assembly.

YES YES
Note : Reference voltage to
(1) supply neutral.

Replace display
Is there voltage to the Correct wiring assembly.
NO
input side of the between primary
primary fuse(s)? fuse and supply.

YES

(2)

Is there voltage to the NO Replace primary


output side of the fuse.
primary fuse(s)?

YES

(3)

Is there voltage Correct wiring


NO
across the primary side between transformer
of the transformer? and primary fuse.

YES

(4)

Is there voltage across


NO
2 & 3 of transformer Replace transformer
secondary?

YES

(5)

Correct wiring
Is there volt age across
NO between hybrid timer
terminals H1-3 &
and transformer
H1-1 on hybrid timer?
secondary.

YES

TMB2000S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 77


Hybrid Timer Control Troubleshooting

Control Has No Display OPL Models (Sheet 1 of 2)

TMB2106S
3

3
1

1
4

4
2

2
3

4
1

1
2

78 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

Control Has No Display OPL Models (Sheet 2 of 2)

TMB2222S
6
5

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 79


Hybrid Timer Control Troubleshooting

34. Display Flashes dr With Door Closed OPL Models


Gas, steam and electric heat.
Single and three phase power supply.
(1) (6)

YES NO Correct wiring


Is there voltage between Is there voltage at
Replace hybrid between secondary
H1-1 & H1-3 on the input of the
control. fuse and
the control? secondary fuse?
transformer.

NO YES

(7)

Is there voltage at NO
NO Replace secondary
Is there power supplied Plug unit in and run output side of
fuse.
to the unit? it. secondary fuse?

YES
YES
(8)
(2)

NO Connect wiring
Is there voltage
Correct wiring between COM and
NO at COM of
Is there voltage at input between primary output of secondary
door switch?
of primary fuses? fuse and power fuse.
supply.

YES
YES
(9)

(3)
With door closed, NO
is there voltage Replace
to NO of door door switch.
Is there voltage at NO
Replace primary switch?
output side of the
fuse(s).
primary fuses?

YES

YES (10)

(4) Connect wiring


Is there voltage NO
at COM of the between door switch
lint panel and COM of lint
NO Correct wiring panel switch.
Is there voltage switch?
between primary
across the
fuse and
transformer primary?
transformer.
YES

(11)
YES

(5) With lint panel NO


closed, is there Replace
power at NO lint panel switch.
connection?
Is there voltage across NO
Replace
terminals 2 &
transformer.
3 of transformer
secondary? YES

Correct wiring between


YES
lint panel switch
and hybrid control.
TMB2052S

80 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

Display Flashes dr With Door Closed OPL Models (Sheet 1 of 2)

TMB2222S
10
1

9 8

7
6
11

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 81


Hybrid Timer Control Troubleshooting

Display Flashes dr With Door Closed OPL Models (Sheet 2 of 2)

TMB2108S
4

4
2

2
5

5
3

3
4

5
2

2
5
3

82 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

35. Vend Satisfied, No In Use LED Coin Models


Vend Satisfied,
No In Use LED (5)
Coin Models
Is Correct wiring
there voltage between the
(1) at the input No transformer
side of the and the
Is secondary
Correct wiring secondary
there voltage fuse?
No between the fuse.
at the input
primary fuse
side of the
and the
primary fuse?
terminal block. Yes
(6)
Yes Is
(2) there voltage
at the output No Replace
Is secondary
side of the
there voltage fuse.
No secondary
at the output Replace the
fuse?
side of the primary fuse.
primary fuse?

Yes
(7)
Yes

(3) Is there Correct wiring


power to the No between
Is
Correct wiring conrol of H1-1
there voltage fuse and
No between the and H1-3?
at the input control.
primary fuse
side of the
and the
transformer?
transformer.
Yes

Yes (8)
Correct wiring
(4) Is between the
there voltage No secondary
Is
there voltage at COM of the fuse and COM
No Replace door switch? of the door
at the output
side of the transformer. switch.
transformer?

Yes
continued on
Yes next page

TMB2022S-a

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 83


Hybrid Timer Control Troubleshooting

35. Vend Satisfied, No In Use LED Coin Models (continued)

continued from
previous page (13)
Is
the H6
(9) connection No Re-seat the
plugged in H6 connection
securely on the to the control.
Is
there voltage No control?
Replace the
at NO of the door switch.
door switch?
Yes

Yes
Is the
(10)
optic-coupler
Is harness Re-seat the
Correct wiring No
there voltage connected optic-coupler
No between the
at COM of the securely into the harness to the
door switch
lint drawer control control.
and lint drawer
switch? switch. harness?

Yes Yes
(11)
Is
there voltage No Replace the
at NO of the lint drawer Replace the No
lint drawer opto-coupler on Replace the
switch.
switch? the coin drop. control.

Yes
(12) Yes

Is Correct wiring
between the Unit is
there power at No
lint drawer operational.
H3-1 and H3-3
on the control? switch and H3
on the control.

Yes
TMB2022S-b

84 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

Vend Satisfied, No In Use LED Coin Models (Sheet 1 of 2)

TMB2106S
3

3
1

1
4

4
2

2
3

4
1

1
4
2

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 85


Hybrid Timer Control Troubleshooting

Vend Satisfied, No In Use LED Coin Models (Sheet 2 of 2)

TMB2232S
12
11

9
8
7
5
6
10

86 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

36. In Use LED Lit, No Motor Run Coin Models


In Use LED Lit,
No Motor Run (5)
Coin Models
Is Correct wiring
there voltage No between the
(1) at the input motor relay
side of the and terminal
Is motor relay?
Correct or block.
there continuity
No replace the
through the
start switch or
start switch
start switch Yes
circuit?
wiring.

(6)
Yes Is
(2) there voltage No
at the output Replace the
Is side of the motor relay.
there voltage No motor relay?
Replace the
at H3-6 on the
control.
control?
Yes

(7)
Yes
Is
(3) there voltage Correct wiring
No between the
across the
Is Correct wiring motor and
lines of the
there voltage No between the motor relay.
motor?
at A1 on the control and
motor relay? the motor
relay A1.
Yes

Yes
Replace the
(4) motor.
Is
Correct wiring
there voltage
No between the
across A1 and
control and
A2 on the
the motor
motor relay?
relay A2.

Yes TMB2023S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 87


Hybrid Timer Control Troubleshooting

In Use LED Lit, No Motor Run Coin Models (Sheet 1 of 2)

TMB2232S
4
3

88 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

In Use LED Lit, No Motor Run Coin Models (Sheet 2 of 2)

TMB2106S
7
7

7
7

6
5

7
6

7
7

5
5

7
7

7
7

5
5

6
6

6
5

6
7

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 89


Hybrid Timer Control Troubleshooting

37. Motor Will Not Start/Run Coin Models


Note: test conducted with vend Gas, electric and steam heat.
(1) price satisfied and start button Single and three phase power supply.
pressed.

Is there voltage across NO Refer to Vend Satisfied,


H3-1 and H3-6 on No In Use LED - Coin Models
the electronic control ? flowchart. (6)

NO Correct wiring
Is there voltage
YES between fan motor
across the lines of
and motor control
(2) the fan motor?
relay.

Is there voltage NO
across H3-4 and H3-6 Replace
YES
on the electronic control? control.
(7)

NO Correct wiring
Is there voltage at
YES between terminal 6
the input side of motor
of motor control
(3) control relay?
relay and supply.

Is there voltage NO
across the coil of Correct wiring to coil
the motor control of motor relay . YES
relay? (8)

Is there voltage at NO
YES Replace motor
the output side of motor
control relay.
control relay?

NOTE: Please use the


appropriate wiring diagram YES
from the following pages.
(9)

NO Correct wiring
Is there voltage
between cylinder
across the lines of
(4) motor and motor
cylinder motor?
control relay.

Is there voltage at NO Correct wiring


the input side of the between control relay YES
motor control relay? and power supply.

YES
(5) NO
Does the cylinder Replace cylinder
motor run? motor.
Is there voltage at NO
Replace motor
the output side of motor
control relay.
control relay?
YES

YES

Motors are
operational.

TMB2047S

Please see following 2 pages for wiring diagram information.

90 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

Motor Will Not Start/Run Coin Models (Sheet 1 of 2)

TMB2232S
3
2
1

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 91


Hybrid Timer Control Troubleshooting

Motor Will Not Start/Run Coin Models (Sheet 2 of 2)

TMB2106S
7
7

7
7

6
5

7
6

7
7

5
5

7
7

7
7

5
5

6
6

6
7

7
9
8

9
4
5

4
5
6

92 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

38. Motor Will Not Start/Run OPL Models


Note: test conducted with vend Gas, electric and steam heat.
(1) price satisfied and start button Single and three phase power supply.
pressed.

Is there voltage across NO Refer to Control Has No


H4-7 and H4-4 on Display - OPL Models
the electronic control ? flowchart. (6)

NO Correct wiring
Is there voltage
YES between fan motor
across the lines of
and motor control
(2) the fan motor?
relay.

Is there voltage NO
across H4-3 and H4-4 Replace
YES
on the electronic control? control.
(7)

NO Correct wiring
Is there voltage at
YES between terminal 6
the input side of motor
of motor control
(3) control relay?
relay and supply.

Is there voltage NO
across the coil of Correct wiring to coil
YES
the motor control of motor relay .
relay? (8)

Is there voltage at NO
YES Replace motor
the output side of motor
control relay.
control relay?

NOTE: Please use the


appropriate wiring diagram YES
from the following pages. (9)

NO Correct wiring
Is there voltage
between cylinder
across the lines of
(4) motor and motor
cylinder motor?
control relay.

Is there voltage at NO Correct wiring


the input side of the between control relay YES
motor control relay? and power supply.

NO
YES Does the cylinder Replace cylinder
(5) motor run? motor.

Is there voltage at NO
Replace motor
the output side of motor YES
control relay.
control relay?

Motors are
YES operational.
TMB2046S

Please see following 2 pages for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 93


Hybrid Timer Control Troubleshooting

Motor Will Not Start/Run OPL Models (Sheet 1 of 2)

TMB2233S
3
2
1

94 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

Motor Will Not Start/Run OPL Models (Sheet 2 of 2)

TMB2106S
7
7

7
7

6
5

7
6

7
7

5
5

7
7

7
7

5
5

6
6

6
7

7
8

8
9

9
4
5

4
5
6

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 95


Hybrid Timer Control Troubleshooting

39. Unit Will Not Heat Gas Coin Models


Note: Tests are conducted with unit running
and calling for heat.
All voltage checks are referenced to
transformer neutral.
(1) (7)

Correct wiring
NO Correct wiring Is there voltage at NO between terminal 3
Is there voltage at terminal 3 of fan of fan motor
between FS-2 and
FS-2 of hybrid control? motor centrifugal centrifugal switch
NO of lint panel.
switch? and terminal 4 of
motor control relay.

YES YES
Replace Replace hybrid
thermistor. control.
(2) (8)

Is there voltage NO NO Is there voltage across YES


at FS-1 of hybrid terminals 3 & 5 of fan motor Replace fan motor.
control? centrifugal switch?

Is the
YES
thermistor
operational?
YES NO

(3) (9)

Correct wiring Correct wiring


NO between COM of Is there voltage to the NO between cabinet
Is there voltage at COM
of airflow switch? airflow switch and input side of the limit and terminal 5
FS-1 of hybrid cabinet limit? of fan motor
control. centrifugal switch.

YES YES

(4) (10)

YES Check for proper YES


Is there voltage across
function of airflow Is there voltage across Replace cabinet
COM & NO terminal
switch and replace if cabinet limit? limit.
of airflow switch?
necessary.

NO NO

(5) (11)

Correct wiring
Is there voltage at NO between terminal 7 NO Correct wiring
on motor control Is there voltage to the
terminal 13 of motor input side of the stove between stove limit 1
control relay? relay and NO and cabinet limit.
terminal on airflow limit 1?
switch.

YES YES

(6)

Is there voltage across YES


Replace motor
terminals 13 & 14 of
control relay.
motor control relay?

NO

96 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

39. Unit Will Not Heat Gas Coin Models (continued)

(12)

YES YES NO Replace gas valve


Is there voltage across Replace the stove Is there gas flow
through the gas valve? coils or complete
the stove limit 1? limit.
gas valve.

NO YES

(13)

Is there voltage to NO Correct wiring NO Replace high


input side of between stove limit 1 Does the igniter spark? voltage ignition
stove limit 2? and stove limit 2. cable or igniter.

YES YES

(14)

Is there voltage YES YES


across stove limit 2? Replace stove limit 2. Is there a flame? Unit operational.

NO

NO
(15)

Is there voltage to Correct wiring


NO
terminal 2 of between terminal 2
the Ignition Control of ICM and stove
Module (ICM)? limit 2.

YES
Note: Make sure unit is
not in a lock out
(16) condition.

Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?

YES

(17)

NO Correct wiring
Is there voltage across
between gas valve
the coils of the gas
and ICM board.
valve?

YES

TMB2048S

Please see following page for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 97


Hybrid Timer Control Troubleshooting

Unit Will Not Heat Gas Coin Models

TMB2232S
17
16
15
7

8
5

14
4
3

12
2

10
1

11

13

98 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601


Hybrid Timer Control Troubleshooting

40. Unit Will Not Heat Gas OPL Models


Note: Tests are conducted with unit running
and calling for heat.
All voltage checks are referenced to
transformer neutral.

(1) (7)

Is there Is the YES


NO NO Replace
voltage at H4-1 thermistor Is there voltage across Replace cabinet
of hybrid control? operational? thermistor limit.
cabinet limit?

YES
YES NO
Replace hybrid
control.
(2) (8)
Correct wiring
Is there voltage at NO between terminal 13 NO Correct wiring
on motor control Is there voltage to the
terminal 13 of motor between stove limit 1
and H4-1 on input side of the stove
control relay? and cabinet limit.
hybrid control. limit 1?

YES YES

(3)
(9)

Is there voltage across YES YES


Replace motor Is there voltage across Replace the stove
terminals 13 & 14 of
control relay. the stove limit 1? limit.
motor control relay?

NO NO

(4) (10)
Correct wiring
Is there voltage at NO between terminal 3
Is there voltage to NO Correct wiring
terminal 3 of fan of fan motor
input side of between stove limit 1
motor centrifugal centrifugal switch
stove limit 2? and stove limit 2.
switch? and terminal 4 of
motor control relay.

YES YES

(5) (11)

Is there voltage across YES YES


Is there voltage
terminals 3 & 5 of fan motor Replace fan motor. Replace stove limit 2.
across stove limit 2?
centrifugal switch?

NO

NO
(6)
(12)
Correct wiring
Is there voltage to the NO between cabinet Is there voltage to Correct wiring
NO
input side of the limit and terminal 5 terminal 2 of between terminal 2
cabinet limit? of fan motor the Ignition Control of ICM and stove
centrifugal switch. Module (ICM)? limit 2.

YES YES

TMB2006S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 99


Hybrid Timer Control Troubleshooting

40. Unit Will Not Heat Gas OPL Models (continued)

Note: Make sure unit is


not in a lock out
condition.
(13)

Is there voltage at NO
terminal 1 of ICM Replace ICM board.
board?

YES

(14)

NO Correct wiring
Is there voltage across
between gas valve
the coils of the gas
and ICM board.
valve?

YES

(15)

NO
Is the airflow switch Replace airflow
working properly? switch

YES

Is there gas flow NO Replace gas valve


through the gas valve? coils or complete
gas valve.

YES

NO Replace high
Does the igniter spark? voltage ignition
cable or igniter.

YES

YES
Is there a flame? Unit operational.

NO

TMB2006S
TMB2006S

Please see following page for wiring diagram information.

100 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Hybrid Timer Control Troubleshooting

Unit Will Not Heat Gas OPL Models

TMB2233S
14
13
12
5

7
4

11
3
2

9
1

6
8

10
15

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 101
Hybrid Timer Control Troubleshooting

41. Unit Will Not Heat Electric OPL


Note: Tests are conducted with unit running
and calling for heat.

All voltage checks are referenced to


transformer neutral.

(6)
(1)

Correct wiring
Is there Is the Is there voltage to the NO between cabinet
NO NO Replace
voltage at H4-1 thermistor input side of the limit and terminal 5
of hybrid control? operational? thermistor
cabinet limit? of fan motor
centrifugal switch.

YES
YES
YES
Replace hybrid
control.
(7)

(2)
YES
Is there voltage across Replace cabinet
Correct wiring cabinet limit? limit.
Is there voltage at NO between terminal 13
terminal 13 of motor on motor control
control relay? relay and hybrid
control.
NO

YES
(8)
(3)

Is there voltage to the NO Correct wiring


input side of the stove between stove limit
Is there voltage across YES limit? and cabinet limit.
Replace motor
terminals 13 & 14 of
control relay.
motor control relay?

YES

NO
(9)

(4)
YES
Correct wiring Is there voltage across Replace the stove
Is there voltage at between terminal 3 the stove limit? limit.
NO
terminal 3 of fan of fan motor
motor centrifugal centrifugal switch
switch? and terminal 14 of
motor control relay.
NO

YES
(10)

(5)
NO Correct wiring
Is there voltage across
between heater
the coil(s) of the heater
Is there voltage across contactor and stove
YES contactor(s)?
terminals 3 & 5 of limit.
Replace fan motor.
fan motor centrifugal switch?

YES

NO

TMB2006S

102 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Hybrid Timer Control Troubleshooting

41. Unit Will Not Heat Electric OPL (continued)


Note: Please make
the oppropriate
adjustments if your
unit is single phase.

(11)

Is there voltage to the NO Correct wiring


L1, L2 and L3 between HC1 and
terminals of HC1? line voltage.

YES

(12)

Is there voltage to the NO Correct wiring


L1, L2 and L3 between HC2 and
terminals of HC2? line voltage.

YES

(13)(14)(15)

NO Check for
Is there voltage across
proper operation of
L3 & L1, L1 & L2 and
contactors, replace
L2 & L3?
them if necessary.

YES

(15)

NO
Is the airflow switch Replace airflow
working properly? switch

YES Unit is operational

(16)

Check elements for


NO shorts or opens.
Do all elements
Check wires
produce heat?
between contactors
and elements.

YES

TMB2053S

Please see following 2 pages for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 103
Hybrid Timer Control Troubleshooting

Unit Will Not Heat Electric OPL (Sheet 1 of 2)

TMB2234S
10
6

7
4

9
3
2
1

104 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Hybrid Timer Control Troubleshooting

Unit Will Not Heat Electric OPL (Sheet 2 of 2)

12 11

13 14 15

TMB2050S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 105
Hybrid Timer Control Troubleshooting

WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

42. Error Codes

Display Definition Corrective Action


OP Open thermistor error. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
SH Shorted thermistor error. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
AF-1 Airflow switch closed when cycle started. Check airflow switch. Replace if
inoperative.
AF-2 Airflow switch failed to closed after cycle Check airflow switch. Replace if
started. inoperative.
AF (flashing) Airflow switch opened/closed 5 or more Check airflow switch. Replace if
times in a running cycle. inoperative.

106 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Section 8
On Premise Micro Control Troubleshooting
Models with OM Control Suffix
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 107
On Premise Micro Control (OM) Troubleshooting

43. Control Has No Display

Control Has No
Display Gas, steam and electric heat.
Single and three phase power supply.

(1)

Is there No Plug unit in


power supplied
and start cycle.
to the unit? (5)
Is there
24 VAC across No Replace
Yes terminals 1 &
transformer.
4 of transformer
secondary?
(2)
Is there Correct wiring
120 VAC No between primary Yes
at input of fuse and power (6)
primary fuses? supply.
Is there Correct wiring
24 VAC across No between
Yes H3-3 and H3-4 on transformer and
the control? control.

(3)
Is there Yes
120 VAC at No Replace primary
output side of the fuse(s).
primary fuses? Is the No
control fuse Replace
functional? control fuse.

Yes
(4) Yes
Is there
120 VAC across Correct wiring
No between primary Replace
terminals 1 & 2 of control.
transformer fuse and
primary? transformer.

Yes
TMB2251S

108 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

Control Has No Display


2 3
1

5
6

TMB2280S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 109
On Premise Micro Control (OM) Troubleshooting

44. Door Open Indicator

Door Open
Indicator Gas, steam and electric heat. Reference voltage
Single and three phase power supply. checks to transformer
neutral.
(1)

Is there
24 VAC between Yes (5)
Replace control.
H2-8 and
Is there
H2-9?
24 VAC across No Replace
terminals 2 & transformer.
3 of transformer
No secondary?

Is there
No Plug unit in and Yes
power supplied
to the unit? start cycle. (6)
Is there Correct wiring
24 VAC at the No between
input of the secondary
Yes
secondary fuse and
(2) fuse? transformer.
Is there Correct wiring
No between primary
120 VAC at input
of primary fuses? fuses and power Yes
supply. (7)

Is there
24 VAC at output No Replace
Yes
(3) side of secondary secondary fuse.
fuse?
Is there
120 VAC at No Replace primary
output side of the fuse(s).
primary fuses? Yes
(8)

Yes Is there Correct wiring


No
24 VAC at COM between COM
(4) and output of
of door switch?
Is there secondary fuse.
120 VAC across Correct wiring
No
terminals 1 & 2 of between primary
transformer fuses and
Yes
primary? transformer.

Continued on
Yes next page
TMB2252S-a

110 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

44. Door Open Indicator (continued)

Continued from
previous page

(9)

With door Check for proper


closed is there 24 No function of door
VAC to N.O. of switch, replace if
door switch? necessary.

Yes

(10)
Is there Correct wiring
24 VAC at COM No between N.O. on
of lint panel door switch and
switch? COM on lint panel
switch.

Yes

(11)
Is there
24 VAC at N.O. Check lint panel
No switch for proper
of lint panel switch
with lint panel operation, replace
closed? if necessary.

Yes

Correct wiring
between H2-8 of
electronic control
and N.O. of lint
panel switch.

TMB2252S-b

Please see following page for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 111
On Premise Micro Control (OM) Troubleshooting

Door Open Indicator

2 3 4

8 9 10 11

TMB2280S

112 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

45. Motor Will Not Start/Run


Note: Test conducted with vend Gas, steam and electric heat.
Motor Will Not
price satisfied and start button Single and three phase power supply.
Start/Run
pressed.
(3)
(1) Is there
Correct wiring
supply voltage at No
Is there between black
No black wire on the
Replace wire and power
voltage between motor control
control. supply.
H2-7 and H2-9? relay?

Yes
Yes
(4)
(2)
Is there Is there
24 VAC across No Correct wiring supply voltage at No Replace motor
the coil of the motor to coil of black wire on the
control relay.
control relay? motor relay . motor control
relay?

Yes
Yes
Note: For high voltage three (5)
Single
phase supply (200 volts or
Is the unit phase
higher), the motor is Is there supply Correct wiring
supplied by L1, L2, equipped with single No between motor
voltage across
L3 through the motor phase or three phase and motor
terminals 1 & 4 of
contactor terminals T1, power? control relay.
the motor?
T2, T3. Make the appropriate
adjustments when doing
voltage checks. 3 phase Yes
Replace
(6)
motor.
Is there
Correct wiring
supply voltage No between L1, L2,
at terminals 5, 3 and 1
at the motor L3 and power (8)
contactor? supply.

Is there
supply voltage Correct wiring
Yes between L1-L2, L2-L3 No between motor
(7) and L1-L3 and T1-T2, and motor
T2-T3 and T1-T3 contactor.
Is there of motors?
supply voltage Yes
at terminals 6, 4 and 2 Replace motor
on the motor control relay.
contactor? Yes
Replace
motor.
No TMB2282S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 113
On Premise Micro Control (OM) Troubleshooting

Motor Will Not Start/Run Single Phase

1 2

TMB2280S

114 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

Motor Will Not Start/Run 3 Phase

TMB2281S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 115
On Premise Micro Control (OM) Troubleshooting

46. Unit Will Not Heat Gas

Note: Tests are conducted with All voltage checks are referenced
Unit Will Not
unit running and calling for heat. to transformer neutral.
Heat Gas

(6)
(1)
Is the Is there Correct wiring
Is there No Yes No between motor
thermistor voltage to terminal 3
voltage at H2-5 of the motor terminal 3 and
operational?
of control? contactor? motor contactor.

No
Yes Yes
(7)
Replace Replace
control. Is there Check motor for
thermistor. No
(2) voltage at terminal proper operation.
5 of the fan Replace if
Is there
Correct wiring motor? necessary.
voltage to the No between airflow
common of the
switch and
airflow
cabinet limit.
switch?
(8)
Is
there Correct wiring
Yes No
voltage to the between cabinet
(3)
input of the limit and terminal
Is there Check for proper cabinet 5 of fan motor.
voltage to the No operation of limit?
N.O. terminal airflow switch.
of the airflow Replace if Yes
switch? necessary.
(9)
Is
there Check cabinet
Yes No limit for proper
voltage to the
(4) output of the operation.
cabinet Replace
Is there if necessary.
No Correct wiring limit?
voltage on BRN
wire on motor between H2-5 and
contactor? motor contactor. Yes
(10)
Yes Is there Correct wiring
voltage to the No between stove
(5)
input of the limit 1 and normally
Is stove limit 1? open terminal of
there No the airflow switch.
voltage at ORG/WHT Replace motor
wire on motor contactor.
contactor? Yes

Continued on
Yes next page TMB2283S-a

116 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

46. Unit Will Not Heat Gas (continued)

Continued from
previous page

Yes
(11) (16)
Is there Check operation Is there Correct wiring
voltage to the No of stove limit 1. voltage across No between gas
output side of the Replace if the coils of the valve and
stove limit 1? necessary. gas valve? ICM board.

Yes Yes
(12)

Is there Correct wiring Replace gas


Is there gas flow No
voltage to the No between stove valve coils or
through the gas complete
input side of the limit 2 and
stove limit 2? stove limit 1. valve? gas valve.

Yes
Yes

(13)
Is there Replace high
Check operation Does the igniter No
voltage to the No voltage ignition
of stove limit 2. spark? cable, igniter or
output side of the
Replace if ICM board.
stove limit 2?
necessary.

Yes
Yes

(14)
Is there
voltage to Correct wiring
No Is there a Yes Unit
terminal 2 of the between terminal 2
Ignition Control of ICM and stove flame? operational.
Module limit.
(ICM)?

Yes No
(15) Note: Make sure unit is
not in a lockout condition.
Is there
voltage at No Replace
terminal 1 of ICM board.
ICM board?

Yes TMB2283S-b

Please see following page for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 117
On Premise Micro Control (OM) Troubleshooting

Unit Will Not Heat Gas

4 5 6 7 8 9 10 11 12 13

14 16

2 3

15

TMB2280S

118 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

47. Unit Will Not Heat Steam

Note: Tests are conducted with All voltage checks are referenced
Unit Will Not
unit running and calling for heat. to transformer neutral.
Heat Steam

Yes
(1) (6)

Is there Is the Yes Is there Correct wiring


No No
voltage at H2-5 thermistor voltage to terminal 3 between motor
of control? operational? of the motor terminal 3 and
contactor? motor contactor.
No
Yes
Yes
Replace Replace (7)
thermistor. control.
(2) Is there Check motor for
voltage at terminal No proper operation.
Is there
Correct wiring 5 of the fan Replace if
voltage to the No between airflow motor? necessary.
common of the
switch and
airflow
cabinet limit.
switch? Yes
(8)
Yes Is
there Correct wiring
(3) No
voltage to the between cabinet
Is there Check for proper input of the limit and terminal
voltage to the No operation of cabinet 5 of fan motor.
N.O. terminal airflow switch. limit?
of the airflow Replace if
switch? necessary. Yes
(9)
Is
Yes there Check cabinet
voltage to the No limit for proper
(4) operation.
output of the
Is there cabinet Replace
voltage on BRN No Correct wiring limit? if necessary.
wire on motor between H2-5 and
contactor? motor contactor.

Continued on
Yes next page
(5)
Is
there No
voltage at ORG/WHT Replace motor
wire on motor contactor.
contactor?

Yes TMB2284S-a

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 119
On Premise Micro Control (OM) Troubleshooting

47. Unit Will Not Heat Steam (continued)

Continued from
previous page

(10)

Is there Correct wiring


24 VAC across No between steam
the coil of the valve coil and
steam valve? motor.

Yes

Does the
No Replace the
steam valve
steam valve
coil have
coil.
continuity?

Yes

Is the steam No Connect the


supply steam supply.
functional?

Yes

Replace or
rebuild the
steam valve.

TMB2284S-b

Please see following page for wiring diagram information.

120 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

Unit Will Not Heat Steam

4 5 6 7 8 9

2 3

10
TMB2280S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 121
On Premise Micro Control (OM) Troubleshooting

48. Unit Will Not Heat Electric

Note: Tests are conducted with All voltage checks are referenced
Unit Will Not
unit running and calling for heat. to transformer neutral.
Heat Electric

(6)
(1)
Is the Is there Correct wiring
Is there No Yes No between motor
thermistor voltage to terminal 3
voltage at H2-5 of the motor terminal 3 and
operational?
of control? contactor? motor contactor.

No
Yes Yes
(7)
Replace Replace
control. Is there Check motor for
thermistor. No
(2) voltage at terminal proper operation.
5 of the fan Replace if
Is there
Correct wiring motor? necessary.
voltage to the No between airflow
common of the
switch and
airflow
cabinet limit.
switch?
(8)
Is
there Correct wiring
Yes No
voltage to the between cabinet
(3)
input of the limit and terminal
Is there Check for proper cabinet 5 of fan motor.
voltage to the No operation of limit?
N.O. terminal airflow switch.
of the airflow Replace if Yes
switch? necessary. (9)
Is
there Check cabinet
Yes No limit for proper
voltage to the
(4) output of the operation.
cabinet Replace
Is there if necessary.
No Correct wiring limit?
voltage on BRN
wire on motor between H2-5 and
contactor? motor contactor. Yes
(10)
Yes Is there Correct wiring
voltage to the No between stove
(5)
input of the limit and normally
Is stove limit ? open terminal of
there No the airflow switch.
voltage at ORG/WHT Replace motor
wire on motor contactor.
contactor? Yes

Continued on
Yes next page TMB2286S-a

122 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

48. Unit Will Not Heat Electric (continued)

Continued from
previous page

(14)(15)
(11)
Check for proper
Is there supply operation of
Is there Check operation No
No voltage across T1-T2, contactors,
voltage to the of stove limit. T2-T3 and T1-T3 ? replace them if
output side of the Replace if
stove limit? necessary. necessary.

Yes
Yes
(12)
Check elements
Is there supply for shorts or
voltage to the L3-L1, No Correct wiring Do all elements No
produce heat (glow opens. Check
L1-L2 and L3-L2 between HC2 and
a slight orange wires between
terminals of HC2? line voltage.
color)? contactors and
elements.

Yes Yes
(13)

Is there supply
voltage to the L1-L2, No Correct wiring Unit
L2-L3 and L1-L3 between HC1 and operational.
terminals of HC1? line voltage.

Yes

TMB2286S-b

Please see following page for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 123
On Premise Micro Control (OM) Troubleshooting

Unit Will Not Heat Electric

12 13

14 15

6 7 8 9 10 11

2 3 4 5

TMB2285S

124 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
On Premise Micro Control (OM) Troubleshooting

WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1

49. Error Codes


OP - Indicates physical open in the thermistor circuit. Possible causes are: 1) thermistor, 2) wiring between
control and thermistor, 3) control.
SH - Indicates a short in the thermistor circuit. Possible causes are: 1) shorted thermistor, 2) a short in the wiring
between control and thermistor, 3) control.

Display Definition Corrective Action


OP Indicates an open circuit in the thermistor. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
SH Indicates a short circuit in the thermistor. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 125
Section 9
Quantum Control Troubleshooting
Models with LC, LX, LY, WC, WX and WY Control Suffixes
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002

126 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

50. No Infrared Communication


Gas and electric heat.
Single and three phase
Attempt to power supply.
communicate with
the electronic
control from the
PDA.

Check the following:


- ls the battery low on the
Is there a response of No No PDA?
Aim PDA Does the control
any kind from the - Is the IR window covered or
closer and try again. respond?
electronic control? blocked on the control?
- If needed, replace the
electronic control.

Yes Yes

Does the electronic -C- Communication


control display E:OF sequence checks
or -C-? out.

E:OF

Check the following:

- Is IR communication disabled
by manual programming?
- Is the IR window on the control
covered or blocked?
- If needed, change control
board.

TMB2269S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 127
Quantum Control Troubleshooting

51. Coins Ignored When Entered


Gas and electric heat.
Single and three phase
power voltage.

Start coin drop


diagnostic tests. NOTE: Refer to Programming Manual
for test procedures.

Yes Exit diagnostic


Does the display on the
testing and reset
electronic control
control. (Prompting
increment properly?
for vend price)

No

Is connector H5 on the No Reconnect and run


control firmly seated in diagnostic test
its receptacle? again.

Yes

Is the 3 pin connector No Reconnect and run


between coin drop and diagnostic test
control connected again.
correctly?

Yes

Are wires exiting coin Yes


drop optical sensor Replace coin drop.
cracked or broken?

No

Replace coin drop.


If problem still exists,
then replace the
electronic control.

TMB1794S

128 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

52. No Display

(1)

Is there 24 volts AC Yes


Replace the
across terminals H1-1
electronic control.
and H1-3 on control?

No

(2)

No
Is the secondary fuse
Replace the fuse.
good?

Yes

(3)

Correct the wiring


Is there 24 volts AC Yes between the
across the red/blue and wht/blue
transformer
wires on the secondary side of
secondary and the
the transformer?
electronic control.

No

(4)

Is line voltage present Yes


across the black and lt blue wires Replace the
on the primary side of transformer.
the transformer?

No

(5)

No
Is the primary fuse Replace the primary
good? fuse.

Yes

Correct wiring from


terminal block to
transformer. Verify
that the unit is
connected to power
and the power is on.

TMB2299S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 129
Quantum Control Troubleshooting

No Display

2 1
4

TMB2295S

130 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

53. Door Open Indicator

Door Open Note: All voltages


Indicator are to be measured (6)
to transformer Is Correct the wiring
common, unless there 24 volts Yes between the fuse
otherwise stated. to the output side of and the common
(1) the secondary terminal of the
Is there fuse? door switch.
24 volts across Yes Replace
terminals H5-7 and control. No
H5-4 on the
control? (7)
Is
there 24 volts Yes Check fuse.
No
to the input side Replace if
(2) of the secondary necessary.
Is Correct the wiring
fuse?
there 24 volts between the N.O.
to the normally open Yes terminal on the lint
contact on the panel switch to No
lint panel terminal H2-1 on
(8)
switch? the control.
Is there Correct wiring
24 volts across Yes between the
No
terminals 2 and 3 transformer and
(3) of the transformer the fuse.
secondary?
Is there 24 volts
to the common Yes Replace the lint
terminal of the lint panel switch.
No
panel switch?
(9)
Is
line voltage
No present across the
Yes Replace
black and lt blue wires
(4) on the primary side of transformer.
Is the transformer?
there 24 volts Correct the wiring
at the normally open Yes between the door
terminal of the door switch and the lint
switch with the door panel switch. No
closed? (10)
Is the No
primary fuse Replace the
No primary fuse.
(5) good?
Is
there 24 volts Check door switch
Yes for proper operation.
to the common Yes Correct wiring from terminal
terminal of the door Replace if
block to transformer. Verify
switch? necessary.
that unit is connected to
power and the power is on.

No
TMB2271S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 131
Quantum Control Troubleshooting

Door Open Indicator

10

9
2 3 4

TMB2295S
T

132 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

54. No Start/Run
*Note: For steps 2 and 3. For 208/240 1 phase, both lines to the motor
are controlled by contacts. Please check second set of contacts.
For 3 phase units, the three legs supplied to the moter will be
controlled by N.O. contacts. Please check all three legs.

(1)

Yes Check motor for


Is there line voltage
proper operation.
across terminals 1 and
Replace if
4 of the motor?
necessary.

No

(2) (5)

Is there 24 volts at Correct wiring


Is there voltage on the Yes Correct wiring terminal H5-3 on the Yes
between the motor between control and
output of the motor control? Measured to
relay and the motor. motor relay coil.
relay?* transformer neutral.

No No

(3) (6)

Correct wiring Press the start


Is there voltage to the No Is there 24 volts to Yes
supplying voltage to button. If machine
input side of the motor terminal H5-7 on the
the contacts of the does not start,
relay?* control?
motor relay. replace control.

Yes No

(4)

Correct wiring to the


Check relay for control. Refer to
Yes
Is there 24 Volts across proper operation. Door Open
the coil of the relay? Replace if Indicator.
necessary.

No

TMB2272S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 133
Quantum Control Troubleshooting

No Start/Run

3 3

2 2

1 1 5

6
4

TMB2295S

134 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

55. Unit Will Not Heat Gas


Note: Tests are conducted with unit running
and calling for heat.
(6)
All voltage checks are referenced to
transformer neutral.
Is there voltage at No Check motor
terminal 5 of the fan or replace if
(1) motor relay? necessary.

No Correct wiring
Is there voltage at between H5-13 and
H5-13 of control? Yes
N.O. of airflow
switch.

(7)

Yes
No Correct wiring
Replace Is there voltage to the
Replace between cabinet
control. input of the cabinet
thermistor. limit and terminal 5
(2) limit?
of fan motor.

Is there voltage No No
Yes
at H5-1 of
control?

Is the Yes (8)


thermistor
Yes operational?
No Check cabinet
Is there voltage to the
limit for proper
output of the cabinet
operation. Replace
(3) limit?
if necessary.

Is there voltage at input No Correct wiring


terminal of the motor between input Yes
control relay? and H5-1.

(9)

Yes
Correct wiring
No
Is there voltage to the between cabinet limit
input of the stove limit? and stove limit
(4) thermostat.

Is there voltage at No
the output terminal Replace relay. Yes
of the fan motor
relay?
(10)

Yes
Is there voltage to the No Check operation of
output side of the stove stove limit. Replace
(5) limit? if necessary.

Check wiring
Is there voltage at No between
terminal 3 of the fan motor terminal 3 Yes
motor? and motor
relay.

Yes
Continued on next
page

TMB2275S-a

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 135
Quantum Control Troubleshooting

55. Unit Will Not Heat Gas (continued)

Yes
Continued from Is there a flame? Unit operational.
previous page

No

(11)

Is there voltage to No Correct wiring


terminal 2 of the between terminal 2
Ignition Control Module of ICM and stove
(ICM)? limit.

Yes
Note: Make sure unit is
not in a lockout
(12) condition.

Is there voltage at No
terminal 1 of ICM Replace ICM board.
board?

Yes

(13)

Is there voltage across No Correct wiring


the coils of the gas between gas valve
valve? and ICM board.

Yes

No Replace gas valve


Is there gas flow
coils or complete
through the gas valve?
gas valve.

Yes

No Replace high
Does the igniter spark? voltage ignition
cable or igniter.

Yes

TMB2275S-b

Please see following page for wiring diagram information.

136 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

Unit Will Not Heat Gas

3 4 5 6

8 7

10 9

TMB2295S
11 12 13

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 137
Quantum Control Troubleshooting

56. Unit Will Not Heat Steam


Note: Tests are conducted with unit running
and calling for heat.

All voltage checks are referenced to


transformer neutral.

(1) (6)

No Correct wiring No Check motor


Is there voltage at
Is there voltage at between H5-13 and or replace if
terminal 5 of fan motor
H5-13 of control? N.O. of airflow necessary.
relay?
switch.

Yes Yes
Replace
Replace
control.
thermistor. (7)
(2)

No Correct wiring
Is there voltage No No Is there voltage to the
between cabinet
at H5-1 of input of the cabinet
limit and terminal 5
control? limit?
of fan motor.
Is the Yes
thermistor
operational? Yes
Yes

(3) (8)

No Check cabinet
No Correct wiring Is there voltage to the
Is there voltage at input limit for proper
between input output of the cabinet
terminal of the motor operation. Replace
terminal and H5-1. limit?
control relay? if necessary.

Yes Yes

(4) (9)

Is there No Check steam


No Does the
voltage at the valve for proper
Replace relay. steam valve
output terminal of the fan operation. Replace
open?
motor relay? if necessary.

Yes Yes

(5)
Verify that the correct
steam is supplied to the
Check wiring unit. Verify that the steam
Is there voltage at No
between motor valve and other items were
terminal 3 of the fan
terminal 3 and installed according to the
motor?
motor relay. Installation Manual.

Yes

TMB2276S

138 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

Unit Will Not Heat Steam

3 4 5 6

TMB2295S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 139
Quantum Control Troubleshooting

57. Unit Will Not Heat Electric


Note: Tests are conducted with unit running
and calling for heat.

All voltage checks are referenced to


transformer neutral.

(1) (6)

No Correct wiring No Check motor


Is there voltage at
Is there voltage at between H5-13 and or replace if
terminal 5 of fan motor
H5-13 of control? N.O. of airflow necessary.
relay?
switch.

Yes
Yes
Replace
Replace
control.
thermistor. (7)
(2)

No Correct wiring
Is there voltage No No Is there voltage to the
between cabinet
at H5-1 of input of the cabinet
limit and terminal 5
control? limit?
of fan motor.
Is the Yes
thermistor
operational? Yes
Yes

(3) (8)

No Check cabinet
No Correct wiring Is there voltage to the
Is there voltage at input limit for proper
between input output of the cabinet
terminal of the motor operation. Replace
terminal and H5-1. limit?
control relay? if necessary.

Yes Yes

(4) (9)

Correct wiring
Is there No between stove limit
No Is there voltage to the
voltage at the and normally open
Replace relay. input of the stove limit?
output terminal of the fan terminal of the
motor relay? airflow switch.

Yes Yes

(5) (10)

No Check motor for Is there voltage to the No Check operation of


Is there voltage at
proper operation. output side of the stove stove limit. Replace
terminal 3 of the fan
Replace if limit? if necessary.
motor?
necessary

Yes Yes

Continued on next
page

TMB2277S-a

140 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

57. Unit Will Not Heat Electric (continued)

Continued from
previous page

(11)

No Correct wiring
Is there voltage across
between heater
the coil(s) of the heater
contactor and
contactor(s)?
stove limit.

Yes

(12)

Is there voltage to the No Correct wiring


input terminals of HC1 between HC1, HC2
and/or HC2? and line voltage.

Yes

(13)

No Check for proper


Is there voltage to the
operation of
output side of
contactors. Replace
HC1/HC2 contacts?
if necessary.

Yes

Check elements for


Do all elements No shorts or opens.
produce heat (glow a Check wires
slight orange color)? between contactors
and elements.

Yes

Unit is operational.

TMB2277S-b

Please see following page for wiring diagram information.

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 141
Quantum Control Troubleshooting

Unit Will Not Heat Electric

12 12 12

2
13 13 13
1

3 4 5 6

8 7

11

10 9

TMB2296S

142 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

58. CE Models No Display


(1) (5)

Is there Correct wiring


Is there voltage across Yes line voltage on the Yes between primary
H1-1 and H1-3 on the Replace the control. output side of the fuse and
control? primary fuse? transformer.

No No

(2) (6)

Is there
Yes Correct wiring Yes Replace primary
Is there voltage coming line voltage on the
between fuse F4 fuse.
out of fuse F4? input side of primary
and control.
fuse?

No No

(2)
Verify that unit is
plugged in. Correct
No wiring between
Is fuse F4 good? Replace fuse. supply terminals
and fuse F1.

Yes

(3)

Correct wiring
Is there voltage across Yes
between
terminals 1 and 4 of
transformer
the transformer?
and fuse.

No

(4)

Check transformer
Is line voltage supplied Yes
for operation.
to the transformer
Replace if
primary?
necessary.

No

TMB2288S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 143
Quantum Control Troubleshooting

CE Models No Display

5
4
3
2
1

TMB2297S

144 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

59. CE Models Door Open Indicator


Note: All voltage checks
are referenced to the
transformer common
unless otherwise
stated.

(1) (6)

Is there voltage across Yes Is there Yes


voltage on Correct wiring
terminals H5-7 and Replace control. between F3 and DS.
H5-3 on the control? output side
of F3?

No
No

(2) (7)

Is there
Is
voltage at Yes Correct wiring Yes
there voltage to
COM terminal of lint between loading Replace fuse.
input side
door switch door and control.
of F3?
(LDS)?

No No

(3) (8)

Make sure lint


door is closed. Is
Is there voltage at Yes there voltage on Yes Correct wiring
Check function
N.C. terminal the secondary side between fuse
of LDS.
of LDS? of transformer? and transformer.
Replace if
necessary.

No No

(4) (9)

Is
there voltage Yes Is there Yes
Correct wiring Replace
at COM terminal voltage supplied to the
between DS transformer.
of door switch primary of the
and LDS.
(DS)? transformer?

No No

(5)
(10)
Make sure door Verify primary fuses are good. Replace
Is there Yes is closed. if necessary. Check and correct wiring
voltage at N.C. terminal Check function between power terminal block and
of DS? of DS. Replace if transformer. Verify machine has
necessary. supply voltage.

No

TMB2289S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 145
Quantum Control Troubleshooting

CE Models Door Open Indicator

10

8
9

6
1

TMB2297S

146 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

60. CE Models No Start/Run


Note: Voltage checks Note: Common can be
referenced to neutral or live wire
transformer depending on voltage
neutral unless and phase.
otherwise stated.

(1) (4)

Is Is Check for proper


Yes Check operation of Yes
there line voltage there voltage across operation of relay.
motor. Replace if
supplied to the the coil of the motor Replace if
necessary.
motor? relay? necessary.

No No

(2) (5)

Is
there voltage on the Is
Yes Correct wiring there voltage across Yes Correct wiring
output side of the between motor relay between control and
motor relay terminals? H5-3 and H5-4 of the
and motor. control? motor relay.
Check to common
line.

No No

(3) (6)

Is Is
there voltage on the No Correct wiring from there voltage to Yes Press start button.
input side of the motor line supply voltage H5-7 on the If machine doesnt
relay terminals? to motor relay. control? start, replace
Check to common control.
line.

Yes No

Correct wiring to
control. Refer to
CE Models Door
Open Indicator.

TMB2291S

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 147
Quantum Control Troubleshooting

CE Models No Start/Run

3 3

2 2

1 1

6 5

TMB2297S

148 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

61. CE Models Will Not Heat Gas/Steam


Note: Voltage checks
Note: Test conducted
referenced to neutral
with unit running and
unless otherwise
calling for heat.
stated.

(1) (7)

Check airflow
No switch (AFS) for No
Is there voltage to input Correct wiring
Is there voltage on proper operation.
side of the cabinet limit between stove limit
H5-13 on the control? If needed correct
(CT)? and MCS.
wiring between
AFS and H5-13.

Yes Yes

(2) (8)

Check thermistor for


No proper operation. No Check CT for
Is there voltage at H5-1 Replace if Is there voltage to the proper operation.
of the control? necessary. Replace output side of the CT? Replace if
control if thermistor necessary.
is good.

Yes Steam See next


Yes
page
Gas
(3) (9)

Correct wiring
Is there voltage at No between H5-1 on No Correct wiring
Is there voltage to between ST-1
terminal 14 of the the control and
input of ST-1? and CT.
K2 relay? terminal 14 of
K2.

Yes Yes

(4) (10)

Check for proper


No No Check function
Is there voltage at operation of the
Is there voltage on of ST-1.
N.O. terminal of the K2 relay.
output side of ST-1? Replace if
K2 relay? Replace if
necessary.
necessary.

Yes Yes

(5) (11)

Is
there voltage to Correct wiring Correct wiring
No Is there voltage on No
the COM terminal of between K2 relay between
terminal 4 of ignition
motor centrifical switch and MCS. terminal 4
control module?
(MCS)? and ST-1.

Yes Yes

(6) (12)

No Check MCS No Correct wiring


Is there voltage on
Is there voltage to the for proper operation. between terminal
terminal 2 of ignition
output side of the MCS? Replace motor if 2 and fuse F3.
module?
necessary.

Yes Yes

Continued on next
TMB2292S-a
page

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 149
Quantum Control Troubleshooting

61. CE Models Will Not Heat Gas/Steam (continued)

Continued from
previous page

(GAS)

(13)

Yes Check valve for proper operation.


Is there voltage
Replace if necessary. Verify correct
supplied to gas valve?
pressure and gas supplied to machine.

No

Verify control is
NOT going into lock-out.
Correct wiring between
valve and ICM. Replace
ICM if necessary.

Continued from
previous page

(Steam)

(14)

Yes Check SV for proper operation.


Is there voltage
Replace if necessary. Verify steam is
across steam valve (SV)?
properly supplied to machine.

No

Correct wiring between


SV and CT.

TMB2292S-b

Please see following page for wiring diagram information.

150 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

CE Models Will Not Heat Gas/Steam

1
7 2

3
4
5

11 12

10 9
13

TMB2297S
14

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 151
Quantum Control Troubleshooting

62. CE Models Will Not Heat Electric


Note: Voltage checks
Note: Test conducted
referenced to neutral
with unit running and
unless otherwise
calling for heat.
stated.

(1) (7)

Check airflow
No switch (AFS) for No
Is there voltage to input Correct wiring
Is there voltage on proper operation.
side of the cabinet limit between stove limit
H5-13 on the control? If needed correct
(CT)? and MCS.
wiring between
AFS and H5-13.

Yes Yes

(2) (8)

Check thermistor for


No proper operation. No Check CT for
Is there voltage to the
Is there voltage at H5-1 Replace if proper operation.
output side of the
of the control? necessary. Replace Replace if
CT?
control if thermistor necessary.
is good.

Yes Yes

(3) (9)

Correct wiring
Is there voltage at No Is No Correct wiring
between H5-1 on
terminal 14 of the there voltage to between ST and
the control and
K2 relay? input of ST? CT.
terminal 14 of K2.

Yes Yes

(4) (10)

Check for proper Is


Is there voltage at No operation of the No Check function
there voltage on
N.O. terminal of the K2 relay. of ST. Replace
output side
K2 relay? Replace if if necessary.
of ST?
necessary.

Yes Yes

(5)

Is there voltage to the Correct wiring Continued on next


No
COM terminal of between K2 page
motor centrifical relay and
switch (MCS)? MCS.

Yes

(6)

No Check MCS
Is there voltage to the
for proper operation.
output side of the
Replace motor
MCS?
if necessary.

Yes

TMB2294S-a

152 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601
Quantum Control Troubleshooting

62. CE Models Will Not Heat Electric (continued)

Continued from
previous page

(11)

Is there line voltage No Correct wiring to


across element contactor contact coils.
coils?

Yes

Do the No Replace
contactors
contactors.
pull in?

Yes

Check for voltage to input side.


Is there voltage No
Correct wiring if necessary. Replace
on the output side
contactor if voltage supplied to
of the contactor?
input side.

Yes

Is there voltage No Correct wiring between


supplied to elements and contactors.
elements?

Yes

No Check element for open CK1.


Is heat produced? Replace if necessary.

Yes

Unit operational.

TMB2294S-b

70380601 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 153
Quantum Control Troubleshooting

CE Models Will Not Heat Electric

1
2 3
4
5

11

8 7
10 9

TMB2298S

154 Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 70380601