You are on page 1of 2

MATRIX control panels by PYRONIX, includes MATRIX 6, MATRIX MX-485 Network is ideal when the requirements are to security

424 and MATRIX 832. The series offers a wide range of and control a multiple objects from a local monitoring center. In
expansion modules, keypads and proximity card readers. this way you can build a network of 248 control panel MATRIX
series, based on RS 485 communication protocol. MX 485 allows
MATRIX 424 makes possible to secure four completely CMS to receive alarm signals from a control panel in the network
independent area, each capable of four of arming modes. using Contact ID. Despite the fact that the control panels are
connected in the MX 485 network, each retains its autonomy and
Control panels are available with two types of LCD keyboards
using built in communicator or MX VOICE can send alarm
that feature a sleek design. For user convenience, the keyboard
messages to another center or voice messages to users of the
have separate buttons for "Panic", "Fire" and "medical care",
system. Standard maximum length of the network is 1 km. Using
and arm /disarm for each of the four areas.
repeaters that distance can be extended
Built-in RS-232 output, and its application software, makes
programming faster, easier and more convenient for each MATRIX series offer suitable solution for almost every commercial or
installer residential application.

.
FUTERES MATRIX 6 MATRIX 424 MATRIX 832
On board programmable inputs 6 8 8
Maximum inputs 6 44 48
Maximum inputs with zone doubling - 60 64
Wireless inputs - 32 32
Zone configuration SEOL, DEOL, N/O, N/C SEOL, DEOL, N/O, N/C SEOL, DEOL, N/O, N/C
Arm modes 4 4 4
Areas - 4 4
Auto Arm - + +
Option Chime + + +
Event memory log 256 256 256
NVM + + +
Maximum keypads per panel 4 4 4
Supported keypads LCD ICON LCD ICON/LCD, proximity reader LCD ICON/LCD, proximity reader
Date & time - + +
PA button on the keypad + + +
Fire alarm button on the keypad + + +
Medical button on the keypad + + +
User codes 15 32 32
RS232 output 1 1 1
On board outputs 4 4 4
Maximum outputs - 12 12
Build in communicator + + +
Supported communication protocols Contact ID, Pyronix PC format Contact ID, Fast format, Pyronix PC format Contact ID, Fast format, Pyronix PC format
IP/GRRS o o o
MX-VOICE o o o
Pyronix MX-485 network + + +
Upload/Download + + +
Supported software UDL. MX-MON UDL. MX-MON UDL. MX-MON
PGM1 Relay contact 30VDC ,3A Relay contact 30VDC ,3A Relay contact 30VDC ,3A
PGM2, PGM3, PGM5, PGM6 Open collector (200mA, 12V) Open collector (200mA, 12V) Open collector (200mA, 12V)
PGM4, PGM7 Open collector (500mA, 12V) Open collector (500mA, 12V) Open collector (500mA, 12V)
PGM4 (2WIRE FIRE detector option) Open collector (10mA, 12V) Open collector (10mA, 12V) Open collector (10mA, 12V)
Power input 17VAC 17VAC 17VAC
Max. capacity power output 1,2A 1,2A 1,2A
Max. power for external devices 600mA 600mA 600mA
Low voltage output 13,8VDC, 1A regulated 13,8VDC, 1A regulated 13,8VDC, 1A regulated
Battery capacity 2,8-7Ah 2,8-7Ah 2,8-7Ah
Operating temperature 0-40 C 0-40 C 0-40 C
Storage temperature -20 40 C -20 40 C -20 40 C
Box type Polymer Polymer Polymer
Security grade/Certification EN50131-1, Security Grade-2 EN50131-1, Security Grade-2 EN50131-1, Security Grade-2
Warranty 2 years 2 years 2 years