You are on page 1of 5

No.

Date: 10/5/2011

Customer :

TECHNICAL PROPOSAL

Three-phase induction motor - Squirrel cage rotor

Product line : Three-Phase : Explosion Proof - High Efficiency

Catalog Number : 10018XP3E405T


List Price : $11,603

Notes:
Three-Phase : Explosion Proof - High Efficiency

Performed by: Checked:


No.:

Date: 10/5/2011

DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer :
Product line : Three-Phase : Explosion Proof - High Efficiency

Frame : 405T
Output : 100 HP
Frequency : 60 Hz
Poles : 4
Full load speed : 1775
Slip : 1.39 %
Voltage : 208-230/460 V
Rated current : 253-229/115 A
Locked rotor current : 1440/721 A
Locked rotor current (Il/In) : 6.3
No-load current : 50.0/25.0 A
Full load torque : 292 lb.ft
Locked rotor torque : 210 %
Breakdown torque : 220 %
Design : B
Insulation class : F
Temperature rise : 80 K
Locked rotor time : 18 s (hot)
Service factor : 1.15
Duty cycle : S1
Ambient temperature : -20C - +40C
Altitude : 1000 m
Degree of Protection : IP55
Approximate weight : 1222 lb
Moment of inertia : 27.403 sq.ft.lb
Noise level : 75 dB(A)

D.E. N.D.E. Load Power factor Efficiency (%)


Bearings 6217 C3 6314 C3 100% 0.87 94.5
Regreasing interval 9149 h 9789 h 75% 0.86 94.5
Grease amount 21 g 27 g 50% 0.80 93.6

Notes:

Performed by: Checked:


No.:

Date: 10/5/2011

PERFORMANCE CURVES RELATED TO RATED OUTPUT


Three-phase induction motor - Squirrel cage rotor
100 1.0 C 0.0

C - Slip
A
90 0.9 1.0

80 0.8 2.0
B
70 0.7 3.0

60 0.6 4.0

50 0.5 5.0

D - Current at 230V (A)


40 0.4 400

300
A - Efficiency (%)

B - Power factor

200

D
100

0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Percent of rated output (%)

Customer :
Product line : Three-Phase : Explosion Proof - High Efficiency

Output : 100 HP Locked rotor current (Il/In) : 6.3


Frame : 405T Duty cycle : S1
Full load speed : 1775 Service factor : 1.15
Frequency : 60 Hz Design : B
Voltage : 208-230/460 V Locked rotor torque : 210 %
Insulation class : F Breakdown torque : 220 %
Rated current : 253-229/115 A

Notes:

Performed by: Checked:


No.:

Date: 10/5/2011

CHARACTERISTIC CURVES RELATED TO SPEED


Three-phase induction motor - Squirrel cage rotor
5.0 10.0

B - Current related to rated current (I/In)


4.5 9.0

4.0 8.0
A - Torque related to rated torque (C/Cn)

3.5 7.0
B
3.0 6.0

2.5 5.0
A
2.0 4.0

1.5 3.0

1.0 2.0

0.5 1.0

0.0 0.0
0 10 20 30 40 50 60 70 80 90 100
Speed related to rated speed (%)
Customer :
Product line : Three-Phase : Explosion Proof - High Efficiency

Output : 100 HP Locked rotor current (Il/In) : 6.3


Frame : 405T Duty cycle : S1
Full load speed : 1775 Service factor : 1.15
Frequency : 60 Hz Design : B
Voltage : 208-230/460 V Locked rotor torque : 210 %
Insulation class : F Breakdown torque : 220 %
Rated current : 253-229/115 A

Notes:

Performed by: Checked:


1 2 3 4 5 6 7 8

Notes:
E

Performed by:
2E A 2F B BA Checked:
16.000 19.921 12.250/13.752 17.520 6.625
J K P ES depth Customer:
3.937 5.433 18.583 5.512 0.750
S N-W U R AB Three-Phase : Explosion Proof - High Efficiency
0.750 7.250 2.875 2.449 16.654
F D G O T H
10.000 1.812 19.843 2.795 0.807
C AA d1 d2 Flange
38.074 NPT 3" DUNC 3/4"-10 DUNC 3/4"-10 FD-508 Three-phase induction motor 10/5/2011
AJ AK BD BF BB Frame 405T - IP55
20.000 18.000 21.656 0.828 0.203