You are on page 1of 38

Click here to view bookmarks.

(Revised 10-26-2015)

C/CW/CC Series
Air Control Valves
3-Way, 3-Port, 2-Position
4-Way, 4-Port, 2-Position

Catalog 0640-E/USA
April 2004
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application including consequences of any failure, and review the information concerning the product or
system in the current product catalog. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this
document entitled Offer of Sale.

Copyright 2004, Parker Hannifin Corporation. All Rights Reserved

Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW/CC Series Valves
Table of Contents Table of Contents

C/CW Basic Valve Features ....................................................................................................... 2


C/CW Model Number Index ....................................................................................................... 3
Single Solenoid & Remote Pressure
CJ1, CWJ1, C10, CW10 ....................................................................................................... 4
Double Remote Pressure & Cam Operated
C12, CW12, C2, CW2 ........................................................................................................... 5
Cam Operated
C94, CW94, C92, CW92, C13, CW13, C9, CW9 .............................................................. 6-7
Hand Operated
C5, CW5, C4, CW4 ............................................................................................................... 8
Hand & Foot Operated
C3, CW3, C6 ......................................................................................................................... 9
Pedal Guard / C/CW Technical Data .................................................................................. 10
Dimensions
3-Way, 2-Position Single Solenoid ...................................................................................... 11
3-Way, 2-Position Remote Pressure ................................................................................... 12
3-Way, 2-Position Heavy Duty Cam Operated .................................................................... 13
3-Way, 2-Position Cam Operated ....................................................................................... 14
3-Way, 2-Position Hand Operated ...................................................................................... 15
3-Way, 2-Position Foot Operated & Guard ......................................................................... 16
CC Basic Valve Features ......................................................................................................... 18
CC Model Number Index .......................................................................................................... 19
Single & Double Solenoid
CCJ1, CCJ11 ...................................................................................................................... 20
Remote Pressure
CC10, CC12 ........................................................................................................................ 21
Cam Operated
CC92, CC94, CC9, CC13, CC2 .....................................................................................22-24
Hand Operated
CC3, CC4, CC5 .............................................................................................................24-25
Foot Operated
CC6 ..................................................................................................................................... 26
Pedal Guard ........................................................................................................................ 26
CC Technical Data ................................................................................................................... 27
Dimensions
4-Way, 4-Port, 2-Position Single Solenoid .......................................................................... 27
4-Way, 4-Port, 2-Position Double Solenoid & Remote Pressure ........................................ 28
4-Way, 4-Port, 2-Position Cam Operated ........................................................................... 29
4-Way, 4-Port, 2-Position Cam & Hand Operated .............................................................. 30
4-Way, 4-Port, 2-Position Foot Operated & Guard ............................................................. 31
Options
Flow Control Section ........................................................................................................... 32
C/CW/CC Cross Reference .................................................................................................33-34
Offer of Sale ............................................................................................................................. 35

1 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Basic Valve Features Air Control Valves

Features
3-Way, 2-Position.

Single Solenoid.

Single Air Pilot.

Manual, cam, hand, and foot operators.

Inline mounting.

Wall or base mounting.

Ports: 1/4 and 3/8 inch.

No minimum operating pressure.

Cv 2.0.

Suitable for vacuum service.


CJ1 Series
May be used as diverter.

Solenoid valve is CSA approved.

Body - sandcast aluminum.

2 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA (Revised 04-06-11) C/CW Series Valves
Model Number Index Air Control Valves

Basic Valve Port Coil


Series Operator Size Option Modification

C J1 25 01 --

Basic Series Port Size Modification


C 2-Position, 3-Way, 3-Port, 25 1/4" Blank None
NC/NO Inline Valve, 37 3/8" * M28 FKM Seals
Horizontal Mounting
CW 2-Position, 3-Way, 3-Port, * Not available
NC/NO Inline Valve, with operator 6
Vertical Mounting
(Wall Mount)

Coil Option - A.C. Solenoid


01 120V/60Hz

Valve Operators
Manual/Mechanical
2 Ball Cam, Spring Return
3 Palm Button, Spring Return
4 Hand Toggle, Non-Locking
5 Hand Toggle, Locking
6 Non-Locking Foot Actuator *
10 Remote Pressure, Spring Return
12 Double Remote Pressure
13 Roller Cam, Spring Return
92 Heavy Duty, Uni-Directional Roller Lever,
Spring Return
94 Heavy Duty, Bi-Directional Roller Lever,
Spring Return

Alternating Current Solenoids
J1 Single Solenoid, Spring Return,
Non-Locking Override
* Available in 1/4" only.

Note: Refer to back of Catalog for


Cross Reference Information.

3 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Single Solenoid & Remote Pressure 3-Way, 2-Position

CJ1 CWJ1 C10 CW10

Application Application
These 3-Way, 2-Position, direct solenoid operated, (maintained These 3-Way, 2-Position, remote pressure operated spool
contact) spool valves are used to operate single acting valves are used to operate single acting cylinders. They
cylinders. They can be used as normally closed or normally can be used as normally closed or normally open, and as
open, and as a 2-Way. a 2-Way.

Mounting Mounting
Intended for inline use. Use C Series for mounting to Intended for inline use. Use C Series for mounting to
horizontal surfaces. Use CW Series for mounting to vertical horizontal surfaces. Use CW Series for mounting to vertical
bulkheads. bulkheads.
Operation Operation
Solenoid De-energized Port A is blocked, port 0 is De-energized or Spring Returned Position of the Spool
connected to port B. When solenoid is energized, port A is Pressure at inlet port A is blocked and port 0 is connected to
connected to port 0 and port B is blocked. Because of the port B. When pilot is energized, port A is connected to port
area-balanced construction of the spool, either port A or port 0 and port B is blocked. Because of the area-balanced
B may be used as the inlet supply port. Pressure to port A construction of the spool, either port A or port B may be used
valve is normally closed valve. Pressure to port B valve is as the inlet supply port. Pressure to port A valve is normally
normally open valve. closed valve. Pressure to port B is normally open valve.

0 0 0 0

A B AB AB AB

Normally Closed Normally Open Normally Closed Normally Open

Model Selection Information Model Selection Information


Following model numbers are for 120V/60Hz.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Base Mounted CJ12501 1/4" NPT Base Mounted C1025
3/8" NPT Base Mounted CJ13701 3/8" NPT Base Mounted C1037

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted CWJ12501 1/4" NPT Wall Mounted CW1025
3/8" NPT Wall Mounted CWJ13701 3/8" NPT Wall Mounted CW1037

4 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Double Remote Pressure & Cam Operated 3-Way, 2-Position

C12 CW12 C2 CW2

Application Application
These 3-Way, 2-Position, double remote pressure operated These 3-Way, 2-Position, cam operated spool valves are used to
spool valves are used to operate single acting cylinders. They operate single acting cylinders. They can be used
can be used as normally closed or normally open, as normally closed or normally open, and as a 2-Way.
and as a 2-Way.
Mounting
Mounting Intended for inline use. Use C Series for mounting to horizontal
Intended for inline use. Use C Series for mounting to surfaces. Use CW Series for mounting to vertical bulkheads.
horizontal surfaces. Use CW Series for mounting to vertical
bulkheads. Operation
Operation De-energized or Spring Returned Position of the Spool
Pressure at inlet port A is blocked and port 0 is connected to
When pressure is applied to port 2 last, pressure at inlet port port B. When ball is activated, port A is connected to port 0
A is blocked and port 0 is connected to port B. When and port B is blocked. Because of the area-balanced
pressure is applied to port 1 last, port A is connected to port construction of the spool, either port A or port B may be used
0 and port B is blocked. Because of the area-balanced as the inlet supply port. Pressure to port A valve is normally
construction of the spool, either port A or port B may be used closed valve. Pressure to port B is normally open valve.
as the inlet supply port. Pressure to port A valve is normally
closed valve. Pressure to port B valve is normally open valve.

#2 #1 #2 #1
Operator Operator Operator Operator
End End End End
0 0 0 0

A B AB AB A B

Normally Closed Normally Open Normally Closed Normally Open

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Base Mounted C1225 1/4" NPT Base Mounted, Ball Cam C225
3/8" NPT Base Mounted C1237 3/8" NPT Base Mounted, Ball Cam C237

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted CW1225 1/4" NPT Wall Mounted, Ball Cam CW225
3/8" NPT Wall Mounted CW1237 3/8" NPT Wall Mounted, Ball Cam CW237

5 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Cam Operated Valves 3-Way, 2-Position

C94 & CW94 Heavy Duty C92 & CW92 Overriding Cam

Application Application
These 3-Way, 2-Position, cam operated spool valves are used These 3-Way, 2-Position, cam operated spool valves are used
to operate single acting cylinders. They can be used to operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.

Mounting Mounting
Intended for inline use. Use C Series for mounting to Intended for inline use. Use C Series for mounting to
horizontal surfaces. Use CW Series for mounting to vertical horizontal surfaces. Use CW Series for mounting to vertical
bulkheads. bulkheads.

Operation Operation
De-energized or Spring Returned Position of the Spool De-energized or Spring Returned Position of the Spool
Pressure at inlet port A is blocked and port 0 is connected to Pressure at inlet port A is blocked and port 0 is connected to
port B. When cam is activated, port A is connected to port 0 port B. When cam is activated, port A is connected to port 0
and port B is blocked. Because of the area-balanced and port B is blocked. Because of the area-balanced
construction of the spool, either port A or port B may be used construction of the spool, either port A or port B may be used
as the inlet supply port. Pressure to port A valve is normally as the inlet supply port. Pressure to port A valve is normally
closed valve. Pressure to port B valve is normally open valve. closed valve. Pressure to port B is normally open valve.
C94 and CW94 operate from either direction. C92 and CW92 are overriding cams which operate in one
direction only.

0 0 0 0

AB A B A B AB
Normally Closed Normally Open Normally Closed Normally Open

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Base Mounted, Heavy Duty, C9425 1/4" NPT Base Mounted, Heavy Duty, C9225
Roller Lever Overriding Roller Lever
3/8" NPT Base Mounted, Heavy Duty, C9437 3/8" NPT Base Mounted, Heavy Duty, C9237
Roller Lever Overriding Roller Lever

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted, Heavy Duty, CW9425 1/4" NPT Wall Mounted, Heavy Duty, CW9225
Roller Lever Overriding Roller Lever
3/8" NPT Wall Mounted, Heavy Duty, CW9437 3/8" NPT Wall Mounted, Heavy Duty, CW9237
Roller Lever Overriding Roller Lever

6 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Cam Operated Valves 3-Way, 2-Position

ED
C13 & CW13 Cam C9 & CW9 Overriding Cam

Application Application

NU
These 3-Way, 2-Position, cam operated spool valves are used These 3-Way, 2-Position, cam operated spool valves are used
to operate single acting cylinders. They can be used to operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.

Mounting Mounting
Intended for inline use. Use C Series for mounting to Intended for inline use. Use C Series for mounting to

TI
horizontal surfaces. Use CW Series for mounting to vertical horizontal surfaces. Use CW Series for mounting to vertical
bulkheads. bulkheads.

Operation Operation ON
De-energized or Spring Returned Position of the Spool De-energized or Spring Returned Position of the Spool
Pressure at inlet port A is blocked and port 0 is connected to Pressure at inlet port A is blocked and port 0 is connected to
port B exhaust as normally closed valve. Because of the area- port B exhaust as a normally closed valve. Because of the
balanced construction of the spool, either port A or port B area-balanced construction of the spool, either port A or port
may be used as the inlet supply port. Pressure to port A valve B may be used as the inlet supply port. Pressure to port A
SC

is normally closed valve. Pressure to port B valve is normally valve is normally closed valve. Pressure to port B valve is
open valve. normally open valve.
DI

0 0 0 0

AB A B A B AB

Normally Closed Normally Open Normally Closed Normally Open

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Base Mounted, Roller Cam C1325 1/4" NPT Base Mounted, Overriding Cam C925
3/8" NPT Base Mounted, Roller Cam C1337 3/8" NPT Base Mounted, Overriding Cam C937

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted, Roller Cam CW1325 1/4" NPT Wall Mounted, Overriding Cam CW925
3/8" NPT Wall Mounted, Roller Cam CW1337 3/8" NPT Wall Mounted, Overriding Cam CW937

7 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Hand Operated Valve 3-Way, 2-Position

C5 CW5 C4 CW4

Application Application
These 3-Way, 2-Position, hand operated spool valves are used These 3-Way, 2-Position, hand operated spool valves are used
to operate single acting cylinders. They can be used to operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.

Mounting Mounting
Intended for inline use. Use C Series for mounting to Intended for inline use. Use C Series for mounting to
horizontal surfaces. Use CW Series for mounting to vertical horizontal surfaces. Use CW Series for mounting to vertical
bulkheads. bulkheads.

Operation Operation
With Hand Lever in Centered Position Pressure at inlet port De-energized or Spring Returned Position of the Spool
A is blocked and port 0 is connected to port B With the Pressure at inlet port A is blocked and port 0 is connected to
hand lever shifted to one place and locked, port A is port B. When hand lever is activated, port A is connected to
connected to port 0 and port B is blocked. Because of the port 0 and port B is blocked. Because of the area-balanced
area-balanced construction of the spool, either port A or port construction of the spool, either port A or port B may be used
B may be used as the inlet supply port. Pressure to port A as the inlet supply port. Pressure to port A valve is normally
valve is normally closed valve. Pressure to port B valve is closed valve. Pressure to port B valve is normally open valve.
normally open valve.

0 0 0 0

A B AB A B AB

Normally Closed Normally Open Normally Closed Normally Open

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4' NPT Base Mounted, Hand Toggle, C525 1/4" NPT Base Mounted, Hand Toggle, C425
Locking Non-Locking
3/8" NPT Base Mounted, Hand Toggle, C537 3/8" NPT Base Mounted, Hand Toggle, C437
Locking Non-Locking

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted, Hand Toggle, CW525 1/4" NPT Wall Mounted, Hand Toggle, CW425
Locking Non-Locking
3/8" NPT Wall Mounted, Hand Toggle, CW537 3/8" NPT Wall Mounted, Hand Toggle, CW437
Locking Non-Locking

8 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Hand & Foot Operated Valves 3-Way, 2-Position

C3 CW3 C6

Application Application
These 3-Way, 2-Position, hand operated spool valves are used These 3-Way, 2-Position, foot operated spool valves are used to
to operate single acting cylinders. They can be used operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.

Mounting Mounting
Intended for inline use. Use C Series for mounting to These valves are designed for side ported, subbase mounting.
horizontal surfaces. Use CW Series for mounting to vertical ! CAUTION:
bulkheads. This valve shall not be used to actuate a punch press. Do
not use this valve on punch presses or press brakes. See
Operation OSHA 1910.217.
De-energized or Spring Returned Position of the Spool
Pressure at inlet port A is blocked and port 0 is connected to Operation
port B. When button is depressed, port A is connected to port De-energized or Spring Returned Position of the Spool
0 and port B is blocked. Because of the area-balanced Pressure at inlet port A is blocked and port 0 is connected to
construction of the spool either port A or port B may be used port B. With foot pedal depressed, port A is connected to port
as the inlet supply port. Pressure to port A valve is normally 0 and port B is blocked. Because of the area-balanced
closed valve. Pressure to port B valve is normally open valve. construction of the spool, either port A or port B may be used
as the inlet supply port. Pressure to port A valve is normally
closed valve. Pressure to port B valve is normally open valve.

0 0

0 0
A B AB

Normally Closed Normally Open


A B AB

Normally Closed Normally Open

Model Selection Information


Port Size Description Model Number
Model Selection Information
1/4" NPT Base Mounted, Palm Button C325
3/8" NPT Base Mounted, Palm Button C337 Port Size Description Model Number
1/4" NPT Base Mounted, Non-Locking C625
Port Size Description Model Number 3/8" NPT Base Mounted, Non-Locking C637 *
1/4" NPT Wall Mounted, Palm Button CW325
See Pedal Guard on following page.
3/8" NPT Wall Mounted, Palm Button CW337
* Discontinued

9 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Foot Operated Valve Pedal Guard 3-Way, 2-Position Technical Data

Operating Pressure
2-Position Solenoid and Mechanical Valve:
0 to 150 PSIG (0 to 1035 kPa)
Also suitable for vacuum service.

2-Position Air Pilot Valve:


0 to 150 PSIG (0 to 1035 kPa)
Also suitable for vacuum service.
Pilot pressures 30 to 150 PSI (207 to 1035 kPa).

Temperature
0F to 140F (18C to 71C)

Electrical Data: 120 Volt AC 60Hz


PS2043 Voltage Range +10/-15% of Nominal
Class B
Application
13.8 Watts 2.1 Amp Inrush .5 Amp Holding
This pedal guard is designed to protect the foot operated valve
from accidental operation that may be caused by falling objects
Note: Coils are not intended for continuous duty
or inadvertent contact.

! CAUTION:
This valve shall not be used to actuate a punch press. Lubrication
Do not use this valve on punch presses or press brakes. Filtered and lubricated air recommended for maximum life and
See OSHA 1910.217. minimum maintenance.

Mounting
2-Position Single Solenoid
Mounting bolts for C6 Foot Valve are furnished in this Kit.
Average Fill Time: (Seconds)*
Valve 12 Cu. In. Test Chamber 100 Cu. In. Test Chamber
Port Size Fill Exhaust Fill Exhaust
1/4" .027 .044 .184 .269
Model Selection Information 3/8" .025 .040 .147 .235
Description Part Number
* With 100 PSI supply, time required to fill from 0-90 PSI and exhaust
Pedal Guard Kit PS2043 from 100 PSI to 10 PSI is measured from instant of energizing, or
de-energizing 120V/60Hz solenoid. Times shown are average.

Flow Rating (Cv)


Valve Port Sizes
Flow Path
1/4" 3/8"
A 0 2.1 2.5
0 A 2.0 2.2
B 0 1.9 2.0
0 B 2.1 2.3
Average 2.0 2.2

10 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Dimensions 3-Way, 2-Position Single Solenoid Valve

Basic Valve Dimensions


A
#6-32 Tap .25 deep
V Y 4 holes
W Z

C B

D
(2 mtg. holes) K
+.02
.19 Travel .00 J
AA
L
A
A A M
X 0
0 0
F N
B B
E E B
G

H P
CJ1
Base Mounted Valve Body

#6-32 Tap .25 deep


A 4 holes
V Y
W Z
U B

H
K
+.02
.19 Travel .00 J

AA D L
(2 mtg.
holes) A
A M
A Q 0 S
X 0 F N
0
B
B B
R
Q
T
CWJ1 Wall Mounted Valve Body

Dimensions:
A B C D E F G H J K
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D
mm 30 27 52 7 33 28 18 65 5.1 25.4
L M N P Q R S T U V
inches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62 3.12
mm 18 4 59 6 19 13 14 54 41 79
W X Y Z AA
inches 1.56 .67 3.60 1.94 5.72
mm 40 17 91 49 145

11 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Dimensions 3-Way, 2-Position Remote Pressure Valve

1/8 NPT 1/8 NPT A

V V
C B
A A
W W
0 0

B
D
B
(2 mtg.
holes)
1/8 NPT
C10 CW10

Basic Valve Dimensions A


A
A W
#6-32 Tap .25 deep Y
0
4 holes F N
B
E B
G
C B
P
H B
K
D +.02
J 1/8 NPT
(2 mtg. .19 Travel .00 C12
holes)
L
A
A M
0
F N
B A
E B
G

H P U B
Base Mounted Valve Body
#6-32 Tap .25 deep H
A 4 holes
1/8 NPT
U B

D
H K (2 mtg.
+.02
.19 Travel .00 J holes) A
A
W
D L Q S Y
0
(2 mtg. F N
holes) A B
A M
B
Q 0 S R
F N
B
B
R T B

T 1/8 NPT
Wall Mounted Valve Body CW12

Dimensions:
A B C D E F G H J K L
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D .69
mm 30 27 52 7 33 28 18 65 5.1 25.4 18
M N P Q R S T U V W Y
inches .16 2.34 .25 .75 .50 .56 2.12 1.62 1.38 3.74 4.25
mm 4 59 6 19 13 14 54 41 35 95 108

12 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Dimensions 3-Way, 2-Position Heavy Duty Cam Operated

.25 Min. Basic Valve Dimensions


to Actuate
Min. Travel
35 to Actuate
80 Max. 1.50
Travel Dia. A
#6-32 Tap .25 deep
4 holes
1.25
3.34
C B
5.73 Max. Overall
Valve Length

D
(2 mtg. holes) K
+.02
J
C92 - CW92 .19 Travel .00
Heavy Duty Overriding L
Roller Lever A
A M
0
1.53 F N
.50 B
E B
.20 G
Actuator May
Be Rotated 180
H P
Base Mounted Valve Body

2.00
1.34
#6-32 Tap .25 deep
A 4 holes
.25
.77
U B
Min. Travel
to Actuate
1.50 Dia. H
35 35 .25 Min. to Actuate K
+.02
.19 Travel .00 J
80 Max.
Travel D L
(2 mtg.
holes) A
A M
1.25
3.34 Q 0 S
F N
B
5.73 Max. Overall B
Valve Length R

T
Wall Mounted Valve Body
C94 - CW94
Heavy Duty
Roller Lever

Dimensions:
A B C D E F G H J K
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D
mm 30 27 52 7 33 28 18 65 5.1 25.4
L M N P Q R S T U
inches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62
mm 18 4 59 6 19 13 14 54 41

13 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Dimensions 3-Way, 2-Position Cam Operated

Cam Operated Basic Valve Dimensions

30 Max.
Cam Angle
.19 Travel A
.62 Dia. #6-32 Tap .25 deep
4 holes
1.41
C B
3.77 Max. Overall
Note: Operates From Valve Length
Any Direction D
(2 mtg. holes) K
C2 - CW2 +.02
.19 Travel .00 J
Ball Cam
L
A
A M
0
F N
Operate B
E B
G
Non-Operate
.50 Dia. 30 Max.
Cam Angle H P
.19 Travel
Base Mounted Valve Body
2.05

4.41 Max. Overall #6-32 Tap .25 deep


Valve Length A 4 holes

C9 - CW9 U B
Overriding Cam

H
K
+.02
.19 Travel .00 J
D L
Operate (2 mtg.
30 Max. holes) A
A M
1.00 Dia. Cam Angle Q 0 S
.19 Travel F N
B
B
1.83 R

T
4.19 Max. Overall Wall Mounted Valve Body
Valve Length
C13 - CW13
Roller Cam

Dimensions:
A B C D E F G H J K
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D
mm 30 27 52 7 33 28 18 65 5.1 25.4
L M N P Q R S T U
inches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62
mm 18 4 59 6 19 13 14 54 41

14 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Dimensions 3-Way, 2-Position Hand Operated Valve

Hand Operated Basic Valve Dimensions

1.31 A
Dia. #6-32 Tap .25 deep
.19 Travel 4 holes

1.03 C B

3.39 Max. Overall


Valve Length
D
C3 - CW3 (2 mtg. holes) K
+.02
Palm Button .19 Travel .00 J

L
A
A M
0
F N
B
E B
G

H P
36 45 Base Mounted Valve Body

4.00 4.00

#6-32 Tap .25 deep


A 4 holes

6.36 6.36
Max. Overall Max. Overall U B
Valve Length Valve Length

H
C4 - CW4 C5 - CW5 K
+.02
Hand Valve Hand Valve .19 Travel .00 J
Non-Locking Locking D L
Handle free to rotate 360 around vertical axis. (2 mtg.
holes) A
A M
Q 0 S
F N
B
B
R

T
Dimensions: Dimensions:
Wall Mounted Valve Body
inches mm inches mm
A 1.19 30 L .69 18
B 1.06 27 M .16 4
C 2.06 52 N 2.34 59
D .28D 7 P .25 6
E 1.28 33 Q .75 19
F 1.12 28 R .50 13
G .72 18 S .56 14
H 2.56 65 T 2.12 54
J .20D 5.1 U 1.62 41
K 1.00D 25.4

15 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Dimensions 3-Way, 2-Position Foot Operated & Guard

Dimensions:
inches mm
A 4.12 105
B 3.16 80
C .88 22
D 1.75 44
M K B
F 4.22 107 L
G .16 4
H .59 15
J .94 24 N

K 2.62 67 B
B

L 1.31 33 0
Q
M 2.06 52 A A

H Travel A
N 2.56 65 P
R
J
P 2.19 56
Q 1.12 28 G C
S
D
R 1.62 41 F

S .19 5

C6 Non-Locking

Foot Valve Guard ! CAUTION:


To order foot valve guard, specify part number PS2043. This valve shall not be used to actuate a punch press.Do
This Kit contains the valve mounting hardware. not use this valve on punch presses or press brakes.
See OSHA 1910.217.

Dimensions:
inches mm A

A 4.50 114
A1 .75 19 A1
B 10.50 267 B1 B C
B1 1.25 32
C .48 11
D 6.00 152
E 7.13 181 E

E1 .50 13 E1
F 13.00 330
F1 8.38 213 D F1
F

16 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW Series Valves
Notes

17 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Basic Valve Features Air Control Valves

Features
4-Way, 2-Position.

Single and Double Solenoid


(Direct Solenoid).

Single and Double Air Pilot.

Manual, cam, hand, and foot


operators.

Mounting: side ported base.

Ports: 1/4 and 3/8 Inch.

No minimum operating pressure


(except air pilot).

Cv 1.5

Suitable for vacuum service.

May be used as diverter.

Available w/sandwich flow controls.


B A

Solenoid valves are CSA approved.

CCJ1 Series
Single Solenoid and Optional
Sandwich Flow Controls

18 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA (Revised 04-06-11) CC Series Valves
Model Number Index Air Control Valves

Basic Valve Port Engineering


Series Operator Options Size Level Coil Modification

CC J1 S 25 B 01 --

Options Engineering Level Modification


Blank None B Current Blank None
S Sandwich Flow Control
(CC Series Only)

Valve Operators Port Size


Manual/Mechanical 25 1/4"
Ball Cam, Spring Return
2 37 3/8"
3 Palm Button, Spring Return VX Valve Assembly
Coil - A.C. Solenoid
4 Hand Toggle, Non-locking Less Base
01 120V/60Hz
5 Hand Toggle, Locking
6 Non-Locking Foot Actuator
10 Remote Pressure, Spring Return
12 Double Remote Pressure
13 Roller Cam, Spring Return
92 Heavy Duty, Uni-Directional Roller
Lever, Spring Return
94 Heavy Duty, Bi-Directional Roller
Lever, Spring Return

ALTERNATING CURRENT SOLENOIDS


J1 Single Solenoid, Spring Return,
Non-Locking Override
J11 Double Solenoid, Momentary Contact

Note: Refer to back of Catalog for


Cross Reference Information.

19 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Single & Double Solenoid Valves 4-Way, 4-Port, 2-Position

CCJ1 Single Solenoid CCJ11 Double Solenoid

Application Application
These 4-Way, 2-Position direct solenoid operated, (maintained These 4-Way, 2-Position direct solenoid operated (momentary
contact) spool valves are used to operate double acting contact) spool valves are used to operate double acting
cylinders. They may also be used as 2-Way or 3-Way valves cylinders. They may also be used as 2-Way or 3-Way valves by
by plugging appropriate ports. plugging appropriate ports.

Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.

Operation Operation
Solenoid De-energized Port A is connected to port 02, Solenoid 1 Last Energized Pressure at inlet port A
port B to port 01. When solenoid is energized, port A connected to outlet port 02. Outlet port 01 connected to
connects to port 01, port B to port 02. Because of the exhaust port B.
area-balanced construction of the spool, either port A or Solenoid 2 Last Energized Pressure at inlet port A
port B may be used as the inlet supply port. connected to outlet port 01. Outlet port 02 connected to
exhaust port B. Because of the area-balanced construction of
the spool, either port A or port B may be used as the inlet
supply port.

Note: Because of direct Solenoid operation, both coils should


not be energized simultaneously.
02 01 02 01

B A B A

Model Selection Information Model Selection Information


Following model numbers are for 120V/60Hz. Following model numbers are for 120V/60Hz.

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Valve with Side Ported Subbase CCJ125B01 1/4" NPT Valve with Side Ported Subbase CCJ1125B01
3/8" NPT Valve with Side Ported Subbase CCJ137B01 3/8" NPT Valve with Side Ported Subbase CCJ1137B01

Following model numbers include the Integral Flow Control Section , Following model numbers include the Integral Flow Control Section,
120V/60Hz. 120V/60Hz.

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Valve with Side Ported Subbase CCJ1S25B01 1/4" NPT Valve with Side Ported Subbase CCJ11S25B01
3/8" NPT Valve with Side Ported Subbase CCJ1S37B01 3/8" NPT Valve with Side Ported Subbase CCJ11S37B01

20 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Remote Pressure Valves 4-Way, 4-Port, 2-Position

CC10 Single Air Pilot CC12 Double Air Pilot

Application Application
These 4-Way, 2-Position remote pressure actuated, spool These 4-Way, 2-Position remote pressure actuated, spool
valves are used to operate double acting cylinders. They may valves are used to operate double acting cylinders. They may
also be used as 2-Way or 3-Way valves by plugging appropriate also be used as 2-Way or 3-Way valves by plugging appropriate
ports. Valves are actuated by maintained pressure signal. ports. Valves are actuated by a momentary pressure signal
alternately to each of the air pilot ports.
Mounting
These valves are designed for side ported, subbase mounting. Mounting
These valves are designed for side ported, subbase mounting.
Operation
De-energized or Spring Returned Position of the Spool Operation
Pressure at inlet port A connected to outlet port 02. Remote Pressure at Piston Actuator #1 Pressure at inlet
Outlet port 01 connected to exhaust port B. When pilot is port A connected to outlet port 02. Outlet port 01
pressurized, port A connects to 01 and port B to port 02. connected to exhaust port B.
Because of the area-balanced construction of the spool, either Remote Pressure at Piston Actuator #2 Pressure at inlet
port A or port B may be used as the inlet supply port. port A connected to outlet port 01. Outlet port 02
connected to exhaust port B. Because of the area-balanced
construction of the spool, either port A or port B may
be used as the inlet supply port.

02 01 02 01
#2 #1
Operator Operator
End End

B A B A

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Spring Return CC1025B 1/4" NPT Side Ported, Remote Pressure Return CC1225B
3/8" NPT Side Ported, Spring Return CC1037B 3/8" NPT Side Ported, Remote Pressure Return CC1237B

Following model numbers include the Integral Flow Control Section . Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Spring Return CC10S25B 1/4" NPT Side Ported, Remote Pressure Return CC12S25B
3/8" NPT Side Ported, Spring Return CC10S37B 3/8" NPT Side Ported, Remote Pressure Return CC12S37B

21 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Heavy Duty Cam Operated Valves 4-Way, 4-Port, 2-Position

CC92 Heavy Duty Overriding Roller CC94 Heavy Duty Roller

Application Application
These 4-Way, 2-Position, cam operated spool valves are used These 4-Way, 2-Position, cam operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
2-Way or 3-Way valves by plugging appropriate ports. The 2-Way or 3-Way valves by plugging appropriate ports. The
heavy duty overriding roller operates in only one direction. heavy duty roller operates in either direction.

Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.

Operation Operation
De-energized or Spring returned Position of the Spool De-energized or Spring Returned Position of the Spool
Pressure at inlet port A connected to outlet port 02. Pressure at inlet port A connected to outlet port 02.
Outlet port 01 connected to exhaust port B. When cam is Outlet port 01 connected to exhaust port B. When cam is
activated, pressure at inlet port A connects to outlet port 01. activated, pressure at inlet port A connects to outlet port 01.
Outlet port 02 connected to exhaust port B. Because of Outlet port 02 connected to exhaust port B. Because of
the area-balanced construction of the spool, either port A the area-balanced construction of the spool, either port A
or port B may be used as the inlet supply port. or port B may be used as the inlet supply port.
CC92 is an overriding cam which operates in one CC94 operates from either direction.
direction only.

02 01 02 01

B A B A

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Heavy Duty, CC9225B 1/4" NPT Side Ported, Heavy Duty, CC9425B
Overriding Roller Lever Roller Lever
3/8" NPT Side Ported, Heavy Duty, CC9237B 3/8" NPT Side Ported, Heavy Duty, CC9437B
Overriding Roller Lever Roller Lever

Following model numbers include the Integral Flow Control Section. Following model numbers include the Integral Flow Control Section.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Heavy Duty, CC92S25B 1/4" NPT Side Ported, Heavy Duty, CC94S25B
Overriding Roller Lever Roller Lever
3/8" NPT Side Ported, Heavy Duty, CC92S37B 3/8" NPT Side Ported, Heavy Duty, CC94S37B
Overriding Roller Lever Roller Lever

22 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Cam Operated Valves 4-Way, 4-Port, 2-Position

CC9 Overriding Roller Cam ED CC13 Roller Cam

Application Application
These 4-Way, 2-Position, cam operated spool valves are used These 4-Way, 2-Position, cam operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
NU

2-Way or 3-Way valves by plugging appropriate ports. The 2-Way or 3-Way valves by plugging appropriate ports. The roller
overriding roller operates in only one direction. operates in either direction.

Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.
TI

Operation Operation
De-energized or Spring Returned Position of the Spool De-energized or Spring Returned Position of the Spool
Pressure at inlet port A connected to outlet port 02. Pressure at inlet port A connected to outlet port 02.
ON

Outlet port 01 connected to exhaust port B. When cam is Outlet port 01 connected to exhaust port B. When cam is
activated, pressure at inlet port A connects to outlet port 01. activated, pressure at inlet port A connects to outlet port 01.
Outlet port 02 connected to exhaust port B. Because of the Outlet port 02 connected to exhaust port B. Because of the
area-balanced construction of the spool, either port A or area-balanced construction of the spool, either port A or
port B may be used as the inlet supply port. port B may be used as the inlet supply port.
SC

CC9 is an overriding cam which operates in one CC13 operates from either direction.
direction only.

02 01 02 01
DI

B A B A

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Overriding Cam CC925B 1/4" NPT Side Ported, Roller Cam CC1325B
3/8" NPT Side Ported, Overriding Cam CC937B 3/8" NPT Side Ported, Roller Cam CC1337B

Following model numbers include the Integral Flow Control Section . Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Overriding Cam CC9S25B 1/4" NPT Side Ported, Roller Cam CC13S25B
3/8" NPT Side Ported, Overriding Cam CC9S37B 3/8" NPT Side Ported, Roller Cam CC13S37B

23 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Cam & Hand Operated Valve 4-Way, 4-Port, 2-Position

CC2 Cam Operated CC3 Hand Operated

Application Application
These 4-Way, 2-Position, cam operated spool valves are used These 4-Way, 2-Position, hand operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
2-Way or 3-Way valves by plugging appropriate ports. 2-Way or 3-Way valves by plugging appropriate ports.

Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.

Operation Operation
De-energized or Spring Returned Position of the Spool De-energized or Spring Returned Position of the Spool
Pressure at inlet port A connected to outlet port 02. Pressure at inlet port A connected to outlet port 02.
Outlet port 01 connected to exhaust port B. When cam is Outlet port 01 connected to exhaust port B. When hand
activated, pressure at inlet port A connects to outlet port 01. button is depressed, pressure at inlet port A connects to
Outlet port 02 connects to exhaust port B. Because of the outlet port 01. Outlet port 02 connected to exhaust port B.
area-balanced construction of the spool, either port A or Because of the area-balanced construction of the spool, either
port B may be used as the inlet supply port. port A or port B may be used as the inlet supply port.

02 01 02 01

B A B A

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Ball Cam CC225B 1/4" NPT Side Ported, Palm Button CC325B
3/8" NPT Side Ported, Ball Cam CC237B 3/8" NPT Side Ported, Palm Button CC337B

Following model numbers include the Integral Flow Control Section. Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Ball Cam CC2S25B 1/4" NPT Side Ported, Palm Button CC3S25B
3/8" NPT Side Ported, Ball Cam CC2S37B 3/8" NPT Side Ported, Palm Button CC3S37B

24 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Hand Operated Valves 4-Way, 4-Port, 2-Position

CC4 Non-Locking CC5 Locking

Application Application
These 4-Way, 2-Position, hand operated spool valves are used These 4-Way, 2-Position, hand operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
2-Way or 3-Way valves by plugging appropriate ports. Valves 2-Way or 3-Way valves by plugging appropriate ports. Valves
are actuated by maintained hand operation. are manually operated and will remain in the last set position
when released.
Mounting
These valves are designed for side ported, subbase mounting. Mounting
These valves are designed for side ported, subbase mounting.
Operation
De-energized or Spring Returned Position of the Spool Operation
Pressure at inlet port A connected to outlet port 02. Outlet With Lever in Centered Position Pressure at inlet port A
port 01 connected to exhaust port B. With hand lever moved connected to outlet port 02. Outlet port 01 connected to
in either full up or full down position, pressure at inlet port A exhaust port B. With the hand lever moved in either full up
connects to outlet port 01. Outlet port 02 connected to or full down position, pressure at inlet port A connects to
exhaust port B. Because of the area-balanced construction outlet port 01. Outlet port 02 connected to exhaust port B.
of the spool, either port A or port B may be used as the Because of the area-balanced construction of the spool, either
inlet supply port. port A or port B may be used as the inlet supply port.

02 01 02 01

B A B A

Model Selection Information Model Selection Information


Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Hand Toggle, CC425B 1/4" NPT Side Ported, Hand Toggle, CC525B
Non-Locking Locking
3/8" NPT Side Ported, Hand Toggle, CC437B 3/8" NPT Side Ported, Hand Toggle, CC537B
Non-Locking Locking

Following model numbers include the Integral Flow Control Section . Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Hand Toggle, CC4S25B 1/4" NPT Side Ported, Hand Toggle, CC5S25B
Non-Locking Locking
3/8" NPT Side Ported, Hand Toggle, CC4S37B 3/8" NPT Side Ported, Hand Toggle, CC5S37B
Non-Locking Locking

25 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Foot Operated Valve & Pedal Guard Foot Operated & Guard

CC6 Foot Operated Valve PS2043 Pedal Guard

Application Application
These 4-Way, 2-Position, foot operated spool valves are used This pedal guard is designed to protect the foot operated valve
to operate double acting cylinders. They may also be used as from accidental operation that may be caused by falling objects
2-Way or 3-Way valves by plugging appropriate ports. or inadvertent contact.

Mounting ! CAUTION:
These valves are designed for side ported, subbase mounting. Foot valves utilizing this guard shall not be used to actuate
a punch press. Do not use this valve on punch presses or
! CAUTION: press brakes. See OSHA 1910.217.
This valve shall not be used to actuate a punch press.
Do not use this valve on punch presses or press brakes. Mounting
See OSHA 1910.217. Mounting bolts for CC6 Foot Valve, opposite, are furnished
in this kit.
Operation
De-energized or Spring Returned Position of the Spool
Pressure at inlet port A connected to outlet port 02.
Outlet port 01 connected to exhaust port B. When pedal is
depressed, pressure at inlet port A connects to outlet port 01.
Outlet port 02 connects to exhaust port B. Because of the
area-balanced construction of the spool, either port A or
port B may be used as the inlet supply port.

02 01

B A

Model Selection Information Model Selection Information


Port Size Description Model Number Description Part Number
1/4" NPT Rear Ported, Non-Locking CC625B Pedal Guard PS2043
3/8" NPT Rear Ported, Non-Locking CC637B

Following model numbers include the Integral Flow Control Section.

Port Size Description Model Number


1/4" NPT Rear Ported, Non-Locking CC6S25B
3/8" NPT Rear Ported, Non-Locking CC6S37B

26 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Technical Information / Dimensions Technical Data / CCJ1 Single Solenoid

Operating Pressure
2-Position Solenoid and Mechanical Valve:
0 to 150 PSIG (0 to 1035 kPa) 1/2 NPSM
02 01
Also suitable for vacuum service.
2-Position Air Pilot Valve:
0 to 150 PSIG (0 to 1035 kPa) C M L
Also suitable for vacuum service.
P
Pilot pressures 30 to 150 PSI (207 to 1035 kPa). N

A B

Temperature R Q
S (2 mtg. holes)
0F to 160F (18C to +71C)
A
A1
Electrical Data: 120 Volt AC 60Hz
Voltage Range +10/-15% of Nominal
Class B D
W/O
13.8 Watts 2.1 Amp Inrush .5 Amp Holding F.C.
D
W/O
Note: Coils are not intended for continuous duty F.C.
B A
F
G
Lubrication J
Filtered and lubricated air recommended for maximum life and K
minimum maintenance. H
E

Average Fill Time: (Seconds)*


2-Position Single Solenoid
Valve 12 Cu. In. Test Chamber 100 Cu. In. Test Chamber
Size Fill Exhaust Fill Exhaust B1
1/4" .034 .620 .028 .411 W/
D1
F.C.
3/8" .031 .630 .179 .385 W/
F.C.

2-Position Double Solenoid A

Valve 12 Cu. In. Test Chamber 100 Cu. In. Test Chamber
Size N1
Fill Exhaust Fill Exhaust
1/4" .034 .620 .206 .407 CCJ1
3/8" .030 .630 .177 .375

* With 100 PSI supply, time required to fill from 0-90 PSI and exhaust
from 100 PSI to 10 PSI is measured from instant of energizing, or
de-energizing 120V/60Hz solenoid. Times shown are average. Dimensions: Dimensions:
inches mm inches mm
A 6.25 159 J .59 15
Flow Rating (Cv) A1 4.75 121 K 1.19 30
Valve Port Sizes
Flow Path B 3.69 94 L 2.56 65
1/4" 3/8"
A 01 1.3 1.8 B1 4.28 109 M 2.06 52
01 A 1.4 1.7 C 3.12 79 N 1.56 40
B 01 1.1 1.4
D 2.56 65 N1 1.97 50
01 B 1.3 1.3
A 02 1.4 1.8 D1 3.15 90 P 1.03 26
02 A 1.3 1.7 E 2.70 69 Q .25 06
B 02 1.3 1.3 F .97 25 R .81 21
02 B 1.2 1.4
G .50 13 S .28 7
Average 1.3 1.5
H 1.38 35

27 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Dimensions Double Solenoid & Remote Pressure

Double Solenoid Pressure Actuated


02 01
1/2 NPSM
02 01

M L

C M L 1/8 NPT P

P
N B A
Q
B A
D (2 mtg. holes)
Q A1
S (2 mtg. holes)
A
A
D
B1
B W/
W/O F.C.
F.C.
B B A
F
W/O G
F.C.
J
K C
H N
B A
F E
G
CC10
J
K 02 01
H
E

M L
1/8 NPT P
2 Places
B A
Q
D (2 mtg. holes)
B1
W/
A2
F.C. A

B1
B W/
W/O F.C.
F.C.
N1
B A
F
G
J C
K N
CCJ11 H
E

CC12

Dimensions: Dimensions: Dimensions: Dimensions:


inches mm inches mm inches mm inches mm
A 9.50 241 K 1.19 30 A 3.00 76 G .50 13
B 3.78 96 L 2.56 65 A1 4.38 111 H 1.35 34
B1 4.37 111 M 2.06 52 A2 5.76 146 J .59 15
C 3.12 79 N 1.56 40 B 2.56 65 K 1.19 30
D 4.75 121 1.97 B1 3.15 80 L 2.56 65
N1 50
E 2.75 70 max. 1.47 M 2.06 52
C 37
P 1.03 26 min.
F .97 25 N1 1.97 50
G .50 13 Q .25 06 D .28 07 max.
.28 E 2.70 69 P 1.03 26
H 1.38 35 S 07
dia. F .97 25 Q .25 06
J .59 15

28 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Dimensions Cam Operated Valve

Heavy Duty Cam Operated


6.34 Max. Overall 5.05 Max. Overall
Valve Length Valve Length
1.50 Dia. 3.34 2.05
1.25 30 Max.
Cam Angle
Min. Travel
to Actuate Non-Operate
Operate
35
.25 Min. .50 Dia.
to Actuate
.19 Travel
80 Max.
Travel CC9 Overriding Cam

4.83 Max. Overall


Valve Length
CC92 Heavy Duty Overriding 1.83
Roller Lever 30 Max.
Cam Angle

.50 .20 .25 Operate

.77 1.00 Dia.


1.53 .19 Travel

CC13 Roller Cam


1.34
Actuator May 2.00
Be Rotated 180
Basic Valve Dimensions
02 01
6.34 Max. Overall
Valve Length
3.34
.25 Min. 1.25 M L
to Actuate
P
1.50 Dia.
B A

Min. Travel 35 Operators Q


to Actuate Attach to D (2 mtg. holes)
this Face
A
35
B1
B W/
80 Max. W/O F.C.
Travel F.C.
B A
F
G
J
K C
CC94 Heavy Duty N
H
Roller Lever E
Valve Body

Dimensions:
A B B1 C D E F G H J
inches 3.00 2.56 3.15 1.47 min. .28 2.70 .987 .50 1.35 .59
mm 76 65 80 37 7 69 25 13 34 15
K L M N P Q
inches 1.19 2.56 2.06 1.97 max. 1.03 .25
mm 30 65 52 50 26 6

29 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Dimensions Cam & Hand Operated

Hand Operated Cam Operated


6.25 Approx. Overall 4.41 Max. Overall
Valve Length Valve Length
3.25 Approx. 1.41
Neutral Position
.19 Travel
CC4: 36 Travel
Either Direction 30 Max.
Cam Angle
CC5: 45 Travel
Either Direction
Note:
Operates From
Any Direction
.62 Dia. Ball

CC2 Ball Cam

CC4 Non-Locking
CC5 Locking

4.03 Max. Overall


Valve Length
1.03
.19 Travel

1.31 Dia.

CC3 Palm Button

Basic Valve Dimensions Dimensions:


02 01 inches mm
A 3.00 76
M L B 2.56 65
P B1 3.15 80
B A
C 1.47 37
Operators Q min.
Attach to D (2 mtg. holes)
this Face
D .28 7
A
E 2.70 69

B
B1 F .97 25
W/
W/O
F.C.
F.C. G .50 13
B A

G
F H 1.35 34
J
C J .59 15
K
H N K 1.19 30
E
L 2.56 65
Valve Body
M 2.06 52

N 1.97 50
max.
P 1.03 26
Q .25 6

30 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Dimensions Foot Operated Valve & Pedal Guard

Dimensions:
inches mm
A 5.19 132
A1 5.77 147
B 4.12 105
C .94 24 J L K
D .59 15 M

E .16 4
F .88 22
N
G 1.75 44 P
H 4.22 107
IN 01
J 2.06 52
K 3.16 80
B
L 2.62 67 EXH 02 Q
D Travel
M 1.31 33 R
C
N 1.09 28
P .55 14 E F
G
Q 3.16 80 H
A A1
R 2.09 53 W/O W/F.C.
F.C.

CC6 Non-Locking
! CAUTION:
This valve shall not be used to actuate a punch press.
Do not use this valve on punch presses or press brakes.
See OSHA 1910.217.

Foot Valve Guard


To order foot valve guard, specify part number PS2043.
This Kit contains the valve mounting hardware.

A
Dimensions:
inches mm
A 4.50 114 A1

A1 .75 19 B1 B C

B 10.50 267
B1 1.25 32
C .48 11
E
D 6.00 152
E 7.13 181 E1

E1 .50 13
F 13.00 330 D F1
F
F1 8.38 213

31 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA CC Series Valves
Options Flow Control Section

Description:
The Integral Flow Control Section can be used with
any CC Series Air Control Valve.

The Flow Control Section, installed between valve


body and base, adds 5/8" to valve height.

All parts are corrosion resistant.


Exhaust air from each cylinder port is directed
through a single valve exhaust port.

Adjusting screws have extra fine threads and


metering tapers designed to provide accurate control
without extreme sensitivity.
Integral Flow Control Section
Operation
The Integral Flow Control Section eliminates the need for
two separate speed control valves. Air is exhausted through
a single valve port, requiring only one muffler or piped
exhaust connection. Adjusting screws with fine threads have
metering tapers designed to give a wide range of control
without extreme sensitivity. Adjustment is made with an
ordinary screwdriver; friction-lock prevents changes in
setting due to vibration.

The Flow Control Section has been designed to give Meter-


Out control of exhaust air flowing FROM Cylinder TO Valve
Exhaust Port. For best results, air supply to valve must be
connected to port A. Lines from cylinder ports on valve to
ports on cylinder should be kept as short as possible to
reduce jump of the cylinder piston when valve shifts.
However, it is possible to connect air supply to port B which
results in Meter-In control of air supply to cylinder. Flow Control Section Installed
The unit can be installed on any CC Series valve already in
use by removing the cap screws that fasten the valve body
assembly to the base, inserting the Flow Control Section Flow Ratings (Cv)
and the gasket between the body and base, and securing Valve Port Size Valve Port Size
Flow Flow
the three components together with the longer cap screws
Path 1/4" 3/8" Path 1/4" 3/8"
provided. Installation is accomplished without disturbing any
electrical or piping connections. Provision is made to prevent A 01 1.63 1.85 A 02 1.66 1.89
improper mounting by means of the locating pin, thus
conforming to J.l.C. recommendations. 01 A 1.57 1.74 02 A 1.49 1.75

B 01 .81 .98 B 02 .87 .95

Ordering Information 01 B .95 .98 02 B 1.05 1.04


To order CC Valves equipped with the Integral Flow
Control Section, see Model Selection Information on When piped for meter-out control, as metering screws are
previous pages. turned in, Cv from cylinder port to exhaust is reduced. Cv from
inlet to cylinder port remains unchanged.
To order the Integral Flow Control Section Kit
separately, specify:
A
Flow Control Section Kit PL504000.
Dimensions:
inches mm B

A 2.70 69
B 2.12 54 C
D
C .28 7
D .78 20
E .56 14 E

32 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW/CC Series Valves
Cross Reference

Obsolete Functional
Part Number Replacement Description / Notes Valve Service Kits
C325M1 C325 Standard size button PL502600
C337M1 C337 Standard size button PL502600
C525M4 C525 Straight handle, locking PL5379
C525M6 C525 Straight handle, locking PL5379

C537M6 C537 Straight handle, locking PL5379


C725 C625 Foot Actuator non-locking PL502500
C737 C637 Foot Actuator non-locking PL502500
C925 C9225 Heavy Duty Overriding Cam Unidirectional 1/4" ports PL502600

C937 C9237 Heavy Duty Overriding Cam Unidirectional 3/8" ports PL502600
CC125B01M8 Use service kit. PL503500
CC325BM1 CC325B Standard size button PL503300
CC337BM1 CC337B Standard size button PL503300

CC3VXBM1 CC3VXB Standard size button PL503300


CC525BM3 CC525B Straight handle, locking PL503300
CC537BM3 CC537B Straight handle, locking PL503300
CC5S25BM3 CC5S25B Straight handle, locking PL503300

CC5VXBM3 CC5VXB Straight handle, locking PL503300


CC5VXBM7 CC5VXB Straight handle, locking PL503300
CC725B CC625B Foot Actuator non-locking PL503300
CC737B CC637B Foot Actuator non-locking PL503300

CC7S25B CC6S25B Foot Actuator non-locking PL503300


CC925B CC9225B Heavy Duty Overriding Cam Unidirectional 1/4" ports PL503300
CC937B CC9237B Heavy Duty Overriding Cam Unidirectional 3/8" ports PL503300
CC9S25B CC92S25B Heavy Duty Overriding Cam Unidirectional 1/4" ports PL503300

CCJ1125B02 PL503200
CCJ1137B01M11 Use service kit. PL5450
CCJ1137B01M28 Use service kit. PL5450
CCJ1137B02 F5215BGC87A Dbl Sol 240vac Valve 3/8" npt PL503200

CCJ11S37B01M11 Use service kit. PL5450


CCJ11S37B01M28 Use service kit. PL5450
CCJ11S37B02 CCJ11S37B01 240 VAC Coils not available, use 120 VAC PL503200
CCJ11S37B06 F5215BGC19001A Dbl Sol 24vdc Valve w/ sandwich flow control PL503200

CCJ125B01M28 Use service kit. PL5450


CCJ125B02 F5E13BGC87A Sgl Sol 240vac valve 1/4 npt PL503000
CCJ125B06 F5E13BGC87A Sgl Sol 24vdc valve 1/4 npt PL503000
CCJ125B15 F5E13BGC23A Sgl Sol 115vac 50hz 1/4 npt PL503000

CCJ125B24 F5E13BGC87A Sgl Sol 230vac/50hz 1/4npt PL503000


CCJ137B02 F5E15BGC87A Sgl Sol 240vac valve 3/8 npt PL503000
CCJ137B15 F5E15BGC23A Sgl Sol 115vac 50hz 3/8 npt PL503000
CCJ137B24 F5E15BGC87A Sgl Sol 230vac/50hz 3/8npt PL503000

CCJ1S25B02 F5E13BGC87001A Sgl Sol 240vac valve 1/4 npt w/ flow control PL503000
CCJ1S25B03 Use service kit. PL503000
CCJ1S37B01M28 Use service kit. PL5450
CCJ1S37B02 F5E15BGC87001A Sgl Sol 240vac valve 3/8 npt w/ flow control PL503000

33 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA C/CW/CC Series Valves
Cross Reference

Obsolete Functional
Part Number Replacement Description / Notes Valve Service Kits
CCJ1SVXB15 Use service kit. PL503000
CCJ1SVXB24 Use service kit. PL503000
CCJ1VXB24 Use service kit. PL503000
CCJY00004 Use service kit. PL5450

CCJY00005 Use service kit. PL5450


CCJY00007 Use service kit. PL5450
CJ12502 F5E13BGC87A Sgl Sol 240vac valve 1/4 npt PL502600
CJ12506 F5E13BGC19A Sgl Sol 24vdc valve 1/4 npt PL502600

CJ12524 F5E13BGC87A Sgl Sol 230vac/50hz 1/4npt PL502600


CJ13701M16 CJ13701 72" leads no longer available, standard w/ 6" leads PL502600
CJ13701M19 See notes Class H coil no longer available PL502600
CJ13702 F5E15BGC87A Sgl Sol 240vac valve 3/8 npt PL502600

CJ13706 F5E15BGC19A Sgl Sol 24vdc valve 3/8 npt PL502600


CJ13715 F5E15BGC23A Sgl Sol 115vac 50hz 3/8 npt PL502600
CJ13724 F5E15BGC87A Sgl Sol 230vac/50hz 3/8 npt PL502600
CW1025M6 CW1025 PL502700

CW13705DC n/a 125VDC not available review application n/a


CW325M1 CW325 Standard size button PL502600
CW337M1 CW337 Standard size button PL502600
CW437M3 CW437 Straight handle, locking PL502600

CW525M3 CW525 Straight handle, locking PL502600


CW925 CW9225 Heavy Duty Overriding Cam Unidirectional 1/4" ports PL502600
CW937 CW9237 Heavy Duty Overriding Cam Unidirectional 3/8" ports PL502600
CWJ12502 B5G1BCH57C B series inline 1/4" npt PL502600

CWJ13702 B5G2BCH57C B series inline 3/8" npt PL502600


CWS125 Use service kit. PL502800
CWS137 Use service kit. PL502800
CWY00005 CW1325 Steel roller instead of Nylon. PL502600

CWY00010 CW9437M28 Nylon roller instead of Steel PL5379


CWY00011 None Review Application PL5379
CWY00012 None Review Application PL5379
CWY00013 None Review Application PL5379

CY00004 Use service kit. PL5379


CY00007 CJ12501 Not available for high temp service PL502600
CY00008 CJ13701 Not available for high temp service PL502600
CY00010 C537 Not available for high temp service PL5379

34 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog 0640-E/USA
Offer Of Sale
The goods, services or work (referred to as the Products) offered by Parker-Hannifin Corporation, its subsidiaries, groups, divisions, and authorized distributors (Seller) are
offered for sale at prices indicated in the offer, or as may be established by Seller. The offer to sell the Products and acceptance of Sellers offer by any customer (Buyer) is
contingent upon, and will be governed by all of the terms and conditions contained in this Offer of Sale. Buyers order for any Products specified in Buyers purchase document
or Sellers offer, proposal or quote (Quote) attached to the purchase order, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer.

1. Terms and Conditions. Sellers willingness to offer Products for sale or accept an (including attorney fees and defense costs), whether for personal injury, property damage,
order for Products is subject to the terms and conditions contained in this Offer of Sale patent, trademark or copyright infringement or any other claim, brought by or incurred
or any newer version of the same, published by Seller electronically at www.parker.com/ by Buyer, Buyers employees, or any other person, arising out of: (a) improper selection,
saleterms/. Seller objects to any contrary or additional terms or conditions of Buyers application, design, specification or other misuse of Products purchased by Buyer from
order or any other document or other communication issued by Buyer. Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Sellers use of patterns,
2. Price; Payment. Prices stated on Sellers Quote are valid for thirty (30) days, except plans, drawings, or specifications furnished by Buyer to manufacture Products; or (d)
as explicitly otherwise stated therein, and do not include any sales, use, or other taxes or Buyers failure to comply with these terms and conditions. Seller shall not indemnify Buyer
duties unless specifically stated. Seller reserves the right to modify prices to adjust for any under any circumstance except as otherwise provided.
raw material price fluctuations. Unless otherwise specified by Seller, all prices are F.C.A. 12. Cancellations and Changes. Buyer may not cancel or modify or cancel any order
Sellers facility (INCOTERMS 2010). Payment is subject to credit approval and payment for any reason, except with Sellers written consent and upon terms that will indemnify,
for all purchases is due thirty (30) days from the date of invoice (or such date as may be defend and hold Seller harmless against all direct, incidental and consequential loss or
specified by Sellers Credit Department). Unpaid invoices beyond the specified payment damage. Seller may change Product features, specifications, designs and availability.
date incur interest at the rate of 1.5% per month or the maximum allowable rate under 13. Limitation on Assignment. Buyer may not assign its rights or obligations under this
applicable law. agreement without the prior written consent of Seller.
3. Shipment; Delivery; Title and Risk of Loss. All delivery dates are approximate. 14. Force Majeure. Seller does not assume the risk and is not liable for delay or failure
Seller is not responsible for damages resulting from any delay. Regardless of the manner to perform any of Sellers obligations by reason of events or circumstances beyond its
of shipment, delivery occurs and title and risk of loss or damage pass to Buyer, upon reasonable control (hereinafter Events of Force Majeure). Events of Force Majeure shall
placement of the Products with the shipment carrier at Sellers facility. Unless otherwise include without limitation: accidents, strikes or labor disputes, acts of any government or
stated, Seller may exercise its judgment in choosing the carrier and means of delivery. No government agency, acts of nature, delays or failures in delivery from carriers or suppliers,
deferment of shipment at Buyers request beyond the respective dates indicated will be shortages of materials, or any other cause beyond Sellers reasonable control.
made except on terms that will indemnify, defend and hold Seller harmless against all loss 15. Waiver and Severability. Failure to enforce any provision of this agreement will not
and additional expense. Buyer shall be responsible for any additional shipping charges invalidate that provision; nor will any such failure prejudice Sellers right to enforce that
incurred by Seller due to Buyers acts or omissions. provision in the future. Invalidation of any provision of this agreement by legislation or
4. Warranty. Seller warrants that the Products sold hereunder shall be free other rule of law shall not invalidate any other provision herein. The remaining provisions
from defects in material or workmanship for a period of twelve (12) months from of this agreement will remain in full force and effect.
the date of delivery or 2,000 hours of normal use, whichever occurs first. All 16. Termination. Seller may terminate this agreement for any reason and at any time
prices are based upon the exclusive limited warranty stated above, and upon by giving Buyer thirty (30) days prior written notice. Seller may immediately terminate this
the following disclaimer: Disclaimer of Warranty: This warranty IS agreement, in writing, if Buyer: (a) breaches any provision of this agreement (b) appoints
the sole and entire warranty pertaining to products provided. a trustee, receiver or custodian for all or any part of Buyers property (c) files a petition
SELLER DISCLAIMS ALL OTHER WARRANTIES, EXPRESS AND IMPLIED, for relief in bankruptcy on its own behalf, or one if filed by a third party (d) makes an
INCLUDING DESIGN, MERCHANTABILITY AND FITNESS FOR A PARTICULAR assignment for the benefit of creditors; or (e) dissolves its business or liquidates all or a
PURPOSE. majority of its assets.
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products 17. Governing Law. This agreement and the sale and delivery of all Products are
upon receipt. No claims for shortages will be allowed unless reported to the Seller within deemed to have taken place in, and shall be governed and construed in accordance with,
ten (10) days of delivery. No other claims against Seller will be allowed unless asserted the laws of the State of Ohio, as applicable to contracts executed and wholly performed
in writing within thirty (30) days after delivery. Buyer shall notify Seller of any alleged therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and
breach of warranty within thirty (30) days after the date the defect is or should have been consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County,
discovered by Buyer. Any claim or action against Seller based upon breach of contract Ohio with respect to any dispute, controversy or claim arising out of or relating to this
or any other theory, including tort, negligence, or otherwise must be commenced within agreement.
twelve (12) months from the date of the alleged breach or other alleged event, without
18. Indemnity for Infringement of Intellectual Property Rights. Seller is not liable for
regard to the date of discovery.
infringement of any patents, trademarks, copyrights, trade dress, trade secrets or similar
6. LIMITATION OF LIABILITY. IN THE EVENT OF A BREACH OF WARRANTY, rights except as provided in this Section. Seller will defend and indemnify Buyer against
SELLER WILL, AT ITS OPTION, REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress and
REFUND THE PURCHASE PRICE WITHIN A REASONABLE PERIOD OF TIME. IN trade secrets (Intellectual Property Rights). Seller will defend at its expense and will pay
NO EVENT IS SELLER LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR the cost of any settlement or damages awarded in an action brought against Buyer based
CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT OF, THE on an allegation that a Product sold pursuant to this agreement infringes the Intellectual
SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF THE Property Rights of a third party. Sellers obligation to defend and indemnify Buyer is
PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR EXPENSES OF contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of
ANY NATURE INCURRED WITHOUT SELLERS WRITTEN CONSENT, WHETHER such allegations of infringement, and Seller having sole control over the defense of any
BASED IN CONTRACT, TORT OR OTHER LEGAL THEORY. IN NO EVENT SHALL allegations or actions including all negotiations for settlement or compromise. If a Product
SELLERS LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED THE is subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller
PURCHASE PRICE OF THE PRODUCTS. may, at its sole expense and option, procure for Buyer the right to continue using the
7. User Responsibility. The user, through its own analysis and testing, is solely Product, replace or modify the Product so as to make it noninfringing, or offer to accept
responsible for making the final selection of the system and Product and assuring that return of the Product and refund the purchase price less a reasonable allowance for
all performance, endurance, maintenance, safety and warning requirements of the depreciation. Notwithstanding the foregoing, Seller is not liable for claims of infringement
application are met. The user must analyze all aspects of the application and follow based on information provided by Buyer, or directed to Products delivered hereunder
applicable industry standards and Product information. If Seller provides Product or for which the designs are specified in whole or part by Buyer, or infringements resulting
system options based upon data or specifications provided by the user, the user is from the modification, combination or use in a system of any Product sold hereunder.
responsible for determining that such data and specifications are suitable and sufficient The foregoing provisions of this Section constitute Sellers sole and exclusive liability and
for all applications and reasonably foreseeable uses of the Products or systems. Buyers sole and exclusive remedy for infringement of Intellectual Property Rights.
8. Loss to Buyers Property. Any designs, tools, patterns, materials, drawings, 19. Entire Agreement. This agreement contains the entire agreement between the
confidential information or equipment furnished by Buyer or any other items which become Buyer and Seller and constitutes the final, complete and exclusive expression of the terms
Buyers property, will be considered obsolete and may be destroyed by Seller after two of sale. All prior or contemporaneous written or oral agreements or negotiations with
(2) consecutive years have elapsed without Buyer ordering the items manufactured using respect to the subject matter are herein merged. The terms contained herein may not be
such property. Seller shall not be responsible for any loss or damage to such property modified unless in writing and signed by an authorized representative of Seller.
while it is in Sellers possession or control. 20. Compliance with Laws. Buyer agrees to comply with all applicable laws, regulations,
9. Special Tooling. A tooling charge may be imposed for any special tooling, including and industry and professional standards of care, including those of the United Kingdom,
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. the United States of America, and the country or countries in which Buyer may operate,
Such special tooling shall be and remain Sellers property notwithstanding payment of including without limitation the U. K. Bribery Act, the U.S. Foreign Corrupt Practices
any charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging Act (FCPA), the U.S. Anti-Kickback Act (Anti-Kickback Act) and the U.S. Food Drug
to Seller which is utilized in the manufacture of the Products, even if such apparatus and Cosmetic Act (FDCA),each as currently amended, and the rules and regulations
has been specially converted or adapted for such manufacture and notwithstanding any promulgated by the U.S. Food and Drug Administration (FDA), and agrees to indemnify
charges paid by Buyer. Unless otherwise agreed, Seller has the right to alter, discard or and hold harmless Seller from the consequences of any violation of such provisions by
otherwise dispose of any special tooling or other property in its sole discretion at any time. Buyer, its employees or agents. Buyer acknowledges that it is familiar with the provisions
10. Buyers Obligation; Rights of Seller. To secure payment of all sums due or of the U. K. Bribery Act, the FCPA, the FDA, and the Anti-Kickback Act, and certifies that
otherwise, Seller retains a security interest in all Products delivered to Buyer and this Buyer will adhere to the requirements thereof. In particular, Buyer represents and agrees
agreement is deemed to be a Security Agreement under the Uniform Commercial Code. that Buyer will not make any payment or give anything of value, directly or indirectly to any
Buyer authorizes Seller as its attorney to execute and file on Buyers behalf all documents governmental official, any foreign political party or official thereof, any candidate for foreign
Seller deems necessary to perfect its security interest. political office, or any commercial entity or person, for the purpose of influencing such
11. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller person to purchase Products or otherwise benefit the business of Seller.
harmless from any losses, claims, liabilities, damages, lawsuits, judgments and costs 05/14

35 Parker Hannifin Corporation


Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Parker Hannifin Corporation
Pneumatic Division Customer/Technical Service
8676 E. M89
Tel: (269) 629-5575
P.O. Box 901
Fax: (269) 629-5385
Richland, MI 49083 USA
Web site: www.parker.com/pneumatic
Tel: (269) 629-5000
E-mail: PDNMKTG@parker.com
Fax: (269) 629-5385
Catalog 0640-E/USA 04/04 IGS Printed in U.S.A.