You are on page 1of 2

MESA 2 - INGENIERA DE RECURSOS HDRICOS SEMESTRE 1 2017 - GRUPO 1

Pregunta 1

Condicin Antecedente de Humedad (AMC)


Variable
Seca (I) Normal (II) Hmeda (III)
CN 56.50 75.56 87.67
Retencin Potencial Mxima (S) (mm) 195.58 82.14 35.71
Abstraccin Inicial (Ia) (mm) 39.12 16.43 7.14

Pregunta 2

Tiempo
Variable
h min

Tiempo de concentracin 7.89 474


Tiempo de retardo 4.74 284

Pregunta 3

T = 200 aos T = 300 aos


Variable
Estacin 1 Estacin 2 Estacin 3 Estacin 1 Estacin 2 Estacin 3
Precipitacin mxima probable 24 h PMP24h (mm) 121.3 113.3 125.1 127.3 118.8 131.1
PMP24h corregida por rea (mm) 103.9 97.1 107.1 109.0 101.8 112.3

T = 100 aos T = 150 aos


Variable
Estacin 1 Estacin 2 Estacin 3 Estacin 1 Estacin 2 Estacin 3
Precipitacin mxima probable 24 h PMP24h (mm) 111.0 103.9 114.7 117.0 109.4 120.8
PMP24h corregida por rea (mm) 95.1 89.0 98.2 100.2 93.7 103.4

Estacin 1 Estacin 2 Estacin 3


Depth Weigth Time Weigth Depth Weigth Time Weigth Depth Weigth Time Weigth
0.27 1 0.39 1 0.34 1

T = 200 aos T = 300 aos


Duracin (mm) Bloque Alterno P (mm) Precipitacin Bloque Alterno P (mm) Precipitacin
Estacin 1 Estacin 2 Estacin 3 Thiessen (mm) Estacin 1 Estacin 2 Estacin 3 Thiessen (mm)

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0


60 0.9 0.8 0.9 0.9 0.9 0.9 1.0 0.9
120 1.2 1.1 1.2 1.2 1.3 1.2 1.3 1.3
180 3.5 3.3 3.6 3.5 3.7 3.5 3.8 3.6
240 68.1 63.7 70.2 67.1 71.5 66.8 73.6 70.4
300 18.4 17.2 19.0 18.1 19.3 18.0 19.9 19.0
360 1.2 1.1 1.2 1.2 1.3 1.2 1.3 1.3
420 0.9 0.8 0.9 0.9 0.9 0.9 1.0 0.9
480 0.9 0.8 0.9 0.9 0.9 0.9 1.0 0.9

T = 100 aos T = 150 aos


Duracin (mm) Bloque Alterno P (mm) Precipitacin Bloque Alterno P (mm) Precipitacin
Estacin 1 Estacin 2 Estacin 3 Thiessen (mm) Estacin 1 Estacin 2 Estacin 3 Thiessen (mm)

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0


60 0.8 0.8 0.9 0.8 0.9 0.8 0.9 0.9
120 1.1 1.0 1.1 1.1 1.2 1.1 1.2 1.2
180 3.2 3.0 3.3 3.2 3.4 3.2 3.5 3.4
240 62.4 58.4 64.4 61.5 65.7 61.5 67.8 64.8
300 16.8 15.8 17.4 16.6 17.7 16.6 18.3 17.5
360 1.1 1.0 1.1 1.1 1.2 1.1 1.2 1.2
420 0.8 0.8 0.9 0.8 0.9 0.8 0.9 0.9
480 0.8 0.8 0.9 0.8 0.9 0.8 0.9 0.9
Pregunta 4

Hidrograma de crecida, condicin seca de humedad antecedente y tormenta hipottica de 150 aos de periodo de retorno:
Total Flow
Date Time
(m3/s)
17-jun-02 10:45 0.1
17-jun-02 11:45 0.1
17-jun-02 12:45 0.1
17-jun-02 13:45 0.1
17-jun-02 14:45 8.5
17-jun-02 15:45 36.4
17-jun-02 16:45 88.5
17-jun-02 17:45 154.5
17-jun-02 18:45 203.6
17-jun-02 19:45 220.6
17-jun-02 20:45 211.1
17-jun-02 21:45 182.3
17-jun-02 22:45 142.1
17-jun-02 23:45 103.8
18-jun-02 00:45 77.1
18-jun-02 01:45 57.3
18-jun-02 02:45 42
18-jun-02 03:45 30.8
18-jun-02 04:45 22.8
18-jun-02 05:45 16.7
18-jun-02 06:45 12.3

Hidrograma de crecida, condicin antecedente de humedad hmeda y tormenta hipottica de 100 aos de periodo de retorno:
Total Flow
Date Time
(m3/s)
30-ene-00 03:05 4.2
30-ene-00 04:05 4.2
30-ene-00 05:05 4.2
30-ene-00 06:05 4.2
30-ene-00 07:05 77.2
30-ene-00 08:05 257.9
30-ene-00 09:05 574.2
30-ene-00 10:05 913.5
30-ene-00 11:05 1106.7
30-ene-00 12:05 1137.9
30-ene-00 13:05 1037.7
30-ene-00 14:05 861.1
30-ene-00 15:05 637.2
30-ene-00 16:05 465.4
30-ene-00 17:05 346
30-ene-00 18:05 258.5
30-ene-00 19:05 189.7
30-ene-00 20:05 140.8
30-ene-00 21:05 104.6
30-ene-00 22:05 77.5
30-ene-00 23:05 58.2

Pregunta 5

Condicin Volumen (1000 m3)


Periodo de
Antecedente de
Retorno (aos) Precipitado Escurrido
Humedad
Seca 150 49989.8 5769.5
Hmeda 100 47450.3 29327.1