PRODUCT INFORMATION

The Mk6E is an enhanced upgrade of the Mk6 meter,


built with a higher class accuracy of 0.2S, catering to
the high-end markets. The Mk6E is a high-precision
meter created for generation and transmission
applications, as well as for revenue metering at
high-end consumer facilities.

KEY FEATURES

AMI READY HIGH LARGE LARGE MEASURE UPGRADEABLE ANTI SCRIPT


ACCURACY DATA STORAGE LCD DISPLAY EVERYTHING TAMPER EXTENSIONS
Mk6E Genius Series - Class 0.2S and Class 0.5S

Smart Three Phase


Electronic Revenue Meter
SPECIFICATIONS

Measurement Mains synchronised or internal Load Survey/Profile Maximum demand control of loads
crystal (TCXO) time keeping. Mains via pulsing outputs
Class 0.2S and Class 0.5S NEM compliant
synchronised reverts to internal Time of use history, etc
IEC 62052-11, IEC 62053-22 (Class Over 900 kilobytes of ash data
crystal (TCXO) on loss of all phase
storage space. Communications
0.2S and Class 0.5S), IEC 62053-23 volts
-3
 100 day-channel capacity at 30 Up to 3 independently working
(Class 2) Data Storage minute intervals communications ports:
3 phase 3 wire Configuration, TOU data and load -1
 875 day capacity at 30 minute
- Optical port: FLAG (IEC 62056-21)
3 phase 4 wire survey data intervals/2 channels
-5
 20 day capacity at 15 minute or ANSI Type 2 (ANSI C12.18)
Voltage - Flash Ram
intervals/3 channels - RS-232 (RTS/CTS and DTR/DCD)
Nominal voltage: 57V - 240V - Battery backed up RAM
(phase to neutral) Up to 50 channels - RS-485 multi-drop (4-wire with RJ45
LCD Display Interval programmable from 1
Burden: <10VA / phase @ Vn or screw terminal)
16 Characters by 2 lines second to 1 month
(3 phase), as per IEC 62053-61 Option for SCADA card
alphanumeric display Multiple independent surveys
Option for internal modem power
Current Programmable units, multipliers and Energy, instantaneous readings,
supply
CT range: leading zeros pulsing inputs, average/min/max
PSTN, UDP/IP, GPRS/PPP capable
Up to 64 user-defined screen readings
1/4A, 1/6A, 5/10A and 5/20A Compatible with MV-90TM
displays
Short time over-current: Time Of Use Support EDMI command line,
Displays any available meter
20 x Imax for 0.5 seconds 8 rates plus unied rate MODBUS, DNP3 level 2,
parameter
Burden: <0.5VA/phase Up to 12 separate import and export IEC 870-5-102, DL/T 645-2007
Optional 20 characters by 4 lines
registers and DLMS protocol
Auxiliary Supply Options alphanumeric display
Up to 200 programmable special Master/Slave arrangement with up
100 to 240 VAC Measured Values days
to 31 Slave meters accessed
Frequency 3 elements, 4 quadrants Daily, weekly, monthly, yearly and
through one Master gateway meter
45Hz - 65Hz Import/Export/Absolute Wh, varh special days
13 or more previous periods Software
Inputs/Outputs Configuration and VAh
Block or rolling maximum demand EziView Windows software
Up to 10 I/O total, independent Phase A, B, C or Total
Time of maximum demand (optional), can be used for
common ground with 4kV isolation W, var, VA programming and reading
Configurable billing rest button
Passive input voltage: True RMS voltage (3 phase) the meter
5V, 12V, 24V, 48V, 110V, 240V True RMS current (3 phase) Extensions for Customer EziView also allows ofine
BOSFET output: Power factor Applications configuration of tariff programs
240V, 100mA maximum Frequency and all meter parameters, for
Mk6E GENIUS plusmeter
2 Programmable LED indicators Phasor angles later upload to meters
continues the successful concept
Programmable output pulse width: of meter Extensions introduced Environmental
Quality of Supply Features
1ms to 250ms in the original Mk6 Genius using
Total Harmonic Distortion (THD) Specified operating range:
Programmable output polarity EziScript, complex register
Unbalance manipulations can be performed -25C to +60C
Time synchronised (optional)
Fundamental voltage, current and allowing sophisticated meter functions. Storage range limit:
Battery watt measurement New extensions are constantly under -25C to +80C
Backup type: Optional lithium battery Harmonics (up to the 50th) development, contact us to nd out the Relative humidity:
1200mAh, 3.6V and SuperCap Sag/Swell latest updates. Up to 95% non-condensing
(single/dual) Some examples of currently available
- 5 Cycle resolution
Backup time: 2 years without power extensions are: Dimensions and Weight
-R
 ecords time/date/phase/duration/
Battery shelf life of 10 plus years at worst excursion Send SMS at percentage of Dimensions: 260mm (L) x
room temperature maximum demand, or equipment 173mm (W) x 93mm (D)
- Programmable trigger levels
failure alarm Weight: 2 kg (standard), 2.2 kg
Real-time Clock Waveform capture (voltage and
Accuracy: 0.5 seconds per day (over current only) (with SCADA card)
full temperature range)

EDMI Limited
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 | Fax: +65 6756 0125
Email: sgmarketing@edmi-meters.com | sgtechsupport@edmi-meters.com www.edmi-meters.com