Professional Documents
Culture Documents
Salwico CS4000
Fire Detection System
Consilium Marine AB
Salwico CS4000
Analogue Addressable
Fire Detection System
Salwico CS4000
Designed in accordance with
EN-54 och marine requirements
Extended redundancy
Operator Panel
Certified to comply with EN-54
Graphical display window
Back lighted push buttons
Logical self instructing system operation,
service and log lists
Suggested measures at failure alarms
Intelligent MMI (Man Machine Interface)
Small dimensions for flexible installation
onboard
Redundant two-way communication
allows remote installation from central
cabinet
Consilium Marine AB
System features
The operator panel can be separated from
the central unit to further facilitate
installation.
Main cabinet size 430x500x158 mm
separate control/repeater panel
288x144x66 mm
Linux based state-of-the-art technology
Extensive interface capability (network,
VDR, paging, telephone, field bus)
Off-the-shelf solution
Start up mode one person can start up
the system
Consilium Marine AB
Interface
Alarm monitoring system
Fire doors, dampers and
sprinklers
Telephone / Paging systems
PLC systems
Ventilation and fans
VDR
Consilium Marine AB
Standard Inputs
- Outputs
9 programmable relay outputs
4 programmable inputs
Opto isolated serial interface
output, RS 232/485 NMEA or
MODBUS
Printer output
Additional inputs on several
PCBs
Consilium Marine AB
Configuration
Free configuration of
fire detection zones regardless of loop
Configuration
Salwico Memory Stick
Loop communication
Loop features
(analogue addressable)
254 addresses per loop
Automatic detection of double addressing,
cable breaks and earth faults at loop level
Easy addressing of detectors
No special cable requirements
Up to 2.000 m loop cable
Addressable loop sounders capabilities
Backwards compatible with all existing installations
Possible to group zones independently of the physical loops
4 12 15
2 9
ZONE 16 7
ZONE 23
ZONE 14
10 ZONE 27
5
1
13
ZONE 18 8 11 ZONE 25
3 14 16
6
ZONE 22
Loop 1 Loop 2
Loop Board LB
Consilium Marine AB
Adaptive detectors
Smoke
FIRE
PRE ALARM
FAULT
Time
Consilium Marine AB
Adaptive detectors
Alarm evaluation
Measure amount of smoke over time
Alarm level
Time
Adaptive detectors
The Cuban cigar
Smoke
100%
Clean air
Time
Standard detector
Consilium Marine AB
Adaptive detectors
Flaming plastics fire
Smoke
100%
Clean air
Time
Adaptive detectors
The midnight poker game
Smoke
100%
Clean air
Time
Standard detector
Consilium Marine AB
Adaptive detectors
Detector testing
Smoke
100%
Clean air
Standard detector
Salwico detector, in test mode
Consilium Marine AB
Adaptive detectors
Detector contamination compensation
Calculate average clean air' value and
keep a constant gap to the alarm level.
Alarm level
Detectors
analogue value
Time
Contamination
(Fault alarm)
Consilium Marine AB
Smoke detectors
NS-AOS
Analogue addressable optical smoke detector
IP 22 or IP 55
NS-AOHS
Analogue addressable combined optical
smoke/heat detector
IP 22 or IP 55
Consilium Marine AB
Smoke
Smoke alarm
Prealarm
Heat
54C
Prealarm
Heat
Heat detectors
NS-AH/AIS
Analogue addressable heat detector 54 degrees
IP 22 or IP 55
Rate of rise function (10 deg C / min)
NS-AH/CS
Analogue addressable heat detector 84 degrees
IP 22 or IP 55
Rate of rise function (10 deg C / min)
SWM-1KL/C
Conventional heat detector, 57 degrees for cold stores
IP 65
Consilium Marine AB
Flame detector
NS-AUV
IP 22 or IP 55
Wavelength: 185-260 um
Consilium Marine AB
NS-ACP-IP55
Addressable manual call point
IP 55
Available in white colour, for sprinkler release
NS-ACPWP
Addressable manual call point
IP 67
Consilium Marine AB
IS equipments, Eex ia
NS-AOS-IS
Analogue addressable optical smoke detector
NS-AOHS-IS
Analogue addressable combined heat/smoke
detector
Dual function
ACP-IS
Addressable manual call point
ISOLATOR A
Max 20 addressable IS units on each isolator
Max 5 isolators on each loop
Does not require separate 24 VDC
Consilium Marine AB
Some accessories
NS-AIN1/2 address unit
Address units with 1 or 2 inputs
Installed on the loop without separate 24
VDC supply
NS-Timer
Timer unit for temporary disconnections
Installed on the loop without separate 24
VDC supply
Consilium Marine AB
UB-2
Base plate for dry space
IP 22
NS-2IP55
Base plate with 2 cable glands for wet space
IP 55
SPB-1
Adapter for wet space
IP 55
Consilium Marine AB
Adaptive detectors
Normal condition
Fire
FIRE
FIRE ALARM 1(1) 06:53
1 FIRE ZONE 61 MCP 612,
Analogue Zone 61, text 1
LB3 address 6l
Fault
FAULT
Disconnection
DISC.
Maintenance features:
TCP/IP for remote service and configuration assistance
Predictive maintenance
Remote maintenance
Remote diagnostics
Remote repair guidance
Support for spare part management
Consilium Marine AB
RS485
Summary
Backwards compatible with all existing
installations
Unique tools for remote service and
configuration assistance
Extended redundancy function including
power supply
254 addresses per loop
Time saving USB or Salwico Memory
Stick connection
The system can be supplied as a mixed
conventional and analouge addressable
system
All type approved
And many more features to come
Consilium Marine AB