You are on page 1of 92

, , Vadodara, Delhi & Kolkata

cover:
Low Voltage & Medium Voltage Switchgear
Switchboard Electrical Design
AC Drives & Building Management Solutions
Protective Relays, Earthing, Reactive Power Management & Harmonics
Energy Conservation & Management

Pune Lucknow Delhi


Larsen & Toubro Limited Larsen & Toubro Limited Larsen & Toubro Limited
Switchgear Training Centre Switchgear Training Centre Switchgear Training Centre
T-156/157, MIDC, Bhosari, C-6&7, UPSIDE, P.O. Sarojini Nagar, 32, Shivaji Marg, Near Moti Nagar Metro Station
Pune - 411 026. Lucknow - 226 008. P.O. Box 6223, New Delhi - 110015.
Tel: (020) 2712 0037 / 2712 0653 Tel: (0522) 247 6015 / 9794454455 Tel: (011) 4141 9515 / 4141 9516
Fax: (020) 2712 2933 Fax: (0522) 247 6015 Fax: (011) 4141 9600
E-mail : STC-PUNE@LNTEBG.COM E-mail : STC-LUCKNOW@LNTEBG.COM E-mail: STC-DELHI@LNTEBG.COM

Coonoor Vadodara Kolkata


Larsen & Toubro Limited Larsen & Toubro Limited Larsen & Toubro Limited
Switchgear Training Centre Ooty-Coonoor Switchgear Training Centre Switchgear Training Centre
Main Road, Yellanahalli Behind L&T Knowledge City, 4th Floor, 3-B, Shakespeare Sarani,
P.O., The Nilgiris - 643 243. Near Village Ankhol, Kolkata - 700071
Tel: (0423) 251 7107 Vadodara - 390 019. Tel: (033) 4400 2151
Fax: (0423) 251 7158 Tel: (0265) 245 7805 E-mail: STC-KOLKATA@LNTEBG.COM
E-mail : STC-COONOOR@LNTEBG.COM E-mail : STC-VADODARA@LNTEBG.COM
Controlgear

Contactors 4

Thermal Overload Relays 12

Control Accessories 14

Motor Protection Circuit Breakers 16

Starters

Motor Starters 18

Digital Soft Starters 24

Powergear

Switch-Disconnector-Fuse Units, SDs & HRC Fuses 26

On Load Changeover Switch-Disconnectors 32

Moulded Case Circuit Breakers 34

Air Circuit Breakers 49

Energy Management

Reactive Power Management Solutions 61

Digital Protective Relays 65

Metering Devices 69

Digital Panel Meters 71

Automation Solution

Programmable Logic Controllers (PLC) 73

Human Machine Interface 74

Modular Devices 76

Type 2 co-ordination selection charts 80

Discontinued Products/Suggested Alternate Products 85


Please contact the nearest branch office for
Prices of the following products :

l Distribution System Components such as 6kA MCBs, EL + MCB etc.

l New Range of Distribution Boards

l AC Variable Frequency Drives

l Servo & Motion Control Solutions

l Wires, Cables and Flat Cables

l Busbar Trunking Systems

l Building Automation Products & Solutions

l Rotary Switches

l Modular Remote Control Units & Indicating Units

l Timing Devices & Supply Monitors

l Cable Ducts & Load Break Switches

l Modular Switches and Sockets

l Diva Solar Lantern

l Medium Voltage AIS upto 36kV

Note: Product photographs shown, are for representative purposes only.

L&T, ESP 01.01.2015


N e w
Contactors
Power Contactors Control Relays Capacitor Duty Definite Purpose
2 Pole 3 Pole 4 Pole (Auxiliary Contactors) Contactors Contactors
l MNX l MX Power l MCX
l MX0 (Mini) l MO C l Single Pole - MR
l MNX l MO0 l MK1
l MO l MN0 l MU
l MDX (DC Control)
l ML

3 Pole Power Contactors


3 Pole Power Contactors - Type MNX 3 Pole Power Contactors - Type MO
Features Features
l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
l Range from 9A 650A AC-3 l Range from 9A - 110A AC-3
l Entire range is UL listed l Compact dimensions saving panel space
l Click fit type construction up to 40A l Lug less termination
l Coil on top design in 95A and above l MO 9/12/18 contactor comes with in-built 1 NO+1 NC in 45mm width
l Spares available for entire range l Standardized accessories throughout the range
l Low pick-up VA consumption
l RoHS compliant

MNX 22 MNX 40 MNX 80

New

MNX 140 MNX 250 MNX 650 MO 18 MO 45 MO 70 MO 110

AC3 AC1 M.R.P. Std. AC3 AC1 M.R.P. Std.


Rating Rating Type Aux. Pkg. Type Aux.
Size Cat. No. (`) Size Rating Rating Cat. No. (`) Pkg.
(A) (A) Contacts Contacts
Per Unit (Nos.) (A) (A) Per Unit (Nos.)
1 NO CS94106 740 10 New 9 30 MO 9 1 NO + 1 NC CS94833 965 10
9 25 MNX 9
1 NC CS94107 740 10 Fr 0 New 12 35 MO 12 1 NO + 1 NC CS94834 1070 10
1 NO CS94108 835 10 New 18 40 MO 18 1 NO + 1 NC CS94835 1215 10
12 30 MNX 12
1 NC CS94109 835 10 25 45 MO 25 # CS94567 1325 10
Fr 1
1 NO CS94100 975 10 32 50 MO 32 # CS94568 2880 10
18 30 MNX 18 Fr 1
1 NC CS94101 975 10 40 50 MO 40 # CS94569 4345 10

MNX 22 1 NO CS94980 1105 10 45 50 MO 45 # CS94570 4865 10


22 32
1 NC CS94981 1105 10 50 65 MO 50 # CS94572 5010 1
25 45 MNX 25 # CS94110 1185 10 Fr 2 60 80 MO 60 # CS94573 6120 1
Fr 2 32 55 MNX 32 # CS94111 2585 10 70 100 MO 70 # CS94574 7070 1
40 55 MNX 40 # CS94190 4050 10 80 125 MO 80 # CS94576 8860 1
45 85 MNX 45 # CS97074 5090 1 Fr 3 95 125 MO 95 # CS94577 10960 1
50 85 MNX 50 # CS97075 5230 1 110 140 MO 110 # CS94578 13100 1
Fr 3
70 100 MNX 70 # CS97076 7405 1
80 100 MNX 80 # CS97077 9250 1
95 160 MNX 95 2 NO + 2 NC CS94136 11855 1 Notes:
Fr 4 110 160 MNX 110 2 NO + 2 NC CS94137 14145 1 1) # Add-on blocks can be ordered separately
2) For ordering MNX/MO add-on aux contact blocks, please refer page No. 8
140 160 MNX 140 2 NO + 2 NC CS94138 18580 1
3) For ordering MNX surge suppressor and MNX/MO MIL kit, please refer page No. 9
185 250 MNX 185 2 NO + 2 NC CS94139 23755 1
4) For ordering Suffix, please refer page No. 9, Table A
Fr 5 225 300 MNX 225 2 NO + 2 NC CS94140 26150 1 5) Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz.
New 250 300 MNX 250 2 NO + 2 NC CS94141 28030 1 6) For ordering spreader link kit for MO 25-45, Please refer page No.9
265 350 MNX 265 2 NO + 2 NC CS94142 31265 1
New 300 400 MNX 300 2 NO + 2 NC CS90280 33760 1
325 400 MNX 325 2 NO + 2 NC CS94143 36230 1
Fr 6
400 425 MNX 400 2 NO + 2 NC CS94144 46360 1
550 650 MNX 550 2 NO + 2 NC CS94145 69145 1
650 800 MNX 650 2 NO + 2 NC CS96327 93850 1

4 L&T, ESP 01.01.2015


2 Pole Power Contactors 3 Pole Power Contactors
2 Pole Power Contactors - Type MNX 3 Pole Power Contactors - Type MDX
Features (DC Control)
l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 Features
l Range from 9A 650A AC-3 l Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
l DC ratings available
l Range from 9 - 110A AC-3
l Click fit type construction up to 40A
l Built in surge suppressor for MDX 9 - 38
l Coil on top design in 95A and above
l IP20 connection security for MDX 9 - 38
l Common spares and accessories as MNX 3P
AC3 AC1 M.R.P. Std.
Type Aux.
Size Rating Rating Contacts
Cat. No. (`) Pkg.
(A) (A) Per Unit (Nos.)
9 25 MNX 9-2P 1 NO CS90232 555 10
12 30 MNX 12-2P 1 NO CS90234 610 10
Fr 1
18 30 MNX 18-2P 1 NO CS90236 710 10 MDX 25 MDX 38 MDX 110
22 32 MNX 22-2P 1 NO CS90238 835 10 AC3 AC1 M.R.P. Std.
Rating Rating Type Aux. Pkg.
25 45 MNX 25-2P # CS90240 900 10 Size Cat. No. (`)
(A) (A) Contacts
Fr 2 32 55 MNX 32-2P # CS90241 1925 10 Per Unit (Nos.)

40 55 MNX 40-2P # CS90242 3040 10 9 25 MDX 9 1 NO CS96564 1450 1


45 85 MNX 45-2P # CS94060 3845 1 12 28 MDX 12 1 NO CS96565 1560 1
Fr 1
50 85 MNX 50-2P # CS94061 4325 1 18 32 MDX 18 1 NO CS96566 1730 1
Fr 3 25 32 MDX 25 1 NO CS96567 2525 1
70 100 MNX 70-2P # CS94062 5450 1
80 100 MNX 80-2P # CS94063 6750 1 32 56 MDX 32 # CS96552 4900 1
Fr 2
95 160 MNX 95-2P 2 NO + 2 NC CS94064 8370 1 38 56 MDX 38 # CS96553 5725 1

Fr 4 110 160 MNX 110-2P 2 NO + 2 NC CS94065 9865 1 50 90 MDX 50 # CS96554 8140 1

140 160 MNX 140-2P 2 NO + 2 NC CS94066 12940 1 65 110 MDX 65 # CS96555 9310 1

185 250 MNX 185-2P 2 NO + 2 NC CS94978 16675 1 Fr 3 80 125 MDX 80 # CS96556 11385 1

Fr 5 225 300 MNX 225-2P 2 NO + 2 NC CS94979 18215 1 95 125 MDX 95 # CS96557 14485 1
110 125 MDX 110 # CS96558 15175 1
New 250 300 MNX 250-2P 2 NO + 2 NC CS90301 19380 1
265 350 MNX 265-2P 2 NO + 2 NC CS94067 21890 1 Notes:
1) # Add-on blocks can be ordered separately.
New 300 400 MNX 300-2P 2 NO + 2 NC CS90346 23345 1
2) For ordering MDX/MNX add-on aux contact blocks, please refer page No. 8
Fr 6 325 400 MNX 325-2P 2 NO + 2 NC CS94068 24795 1 3) For ordering MDX/MNX surge suppressor and MIL kit, please refer page No. 9
400 425 MNX 400-2P 2 NO + 2 NC CS94069 31465 1 4) For ordering Suffix, please refer page No. 9, Table A
5) Standard coil voltage: MDX - 24V, 48V, 110V and 220V DC.
550 650 MNX 550-2P 2 NO + 2 NC CS90243 48985 1
6) Standard coil voltage: MNX 2P - 240V, 50Hz
New 650 800 MNX 650-2P 2 NO + 2 NC CS90578 66490 1

3 Pole Power Contactors


3 Pole Power Contactors - Type MX Mini 3 Pole Power Contactors - Type ML
Features Features
l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 l Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
l AC/DC Contactor in 45mm width l Range from 25 - 300A AC-3
l Base as well as DIN Rail mounting facility l Robust and suitable for hostile applications
l Inbuilt Surge Suppressor in MX DC

MX 06 ML 1.5 ML 3 ML 6 ML 12
AC3 AC1 M.R.P. Std. AC3 AC1 M.R.P. Std.
Rating Rating Type Aux. Pkg. Rating Rating Type Aux. Pkg.
Cat. No. (`) Size Cat. No. (`)
(A) (A) Contact (Nos.) (A) (A) Contacts
Per Unit Per Unit (Nos.)
For AC control (Std. Coil Voltage - 24, 110, 240, 415V, 50Hz) Fr 1 25 25 ML 1.5 2 NO + 2 NC SS91851 2340 1
6A 20A MX 06 1 NO CS94012 690 10 32 40 ML 2 2 NO + 2 NC SS90701 4345 1
Fr 2
6A 20A MX 06 1 NC CS94013 690 10 40 45 ML 3 2 NO + 2 NC SS90721 6415 1
9A 20A MX 09 1 NO CS94014 725 10 70 100 ML 4 2 NO + 2 NC SS90910 10490 1
Fr 3
9A 20A MX 09 1 NC CS94015 725 10 110 125 ML 6 2 NO + 2 NC SS90921 16560 1
12A 20A MX 12 1 NO CS94016 800 10 200 250 ML 10 * 2 NO + 2 NC SS90935 36580 1
Fr 4
12A 20A MX 12 1 NC CS94017 800 10 300 400 ML 12 * 2 NO + 2 NC SS91010 39385 1
For DC control (Std. Coil Voltage - 24, 110, 220V)
Notes:
6A 20A MX 06 1 NO CS94021 1030 10
1) For ordering ML/MX add-on aux contact blocks, please refer page No. 8
6A 20A MX 06 1 NC CS94022 1030 10 2) For ordering MX surge suppressor and MIL kit, please refer page No. 9
9A 20A MX 09 1 NO CS94023 1080 10 3) For Ordering Suffix, please refer page No. 9, Table A
9A 20A MX 09 1 NC CS94024 1080 10 4) Std. Coil Voltage: ML - 110V, 240V and 415V, 50Hz

12A 20A MX 12 1 NO CS94025 1180 10


* Available till stock last
12A 20A MX 12 1 NC CS94026 1180 10

L&T, ESP 01.01.2015 5


4 Pole Power Contactors & AST System Components
4 Pole Power Contactors - Type MCX Auto Source Transfer Controller
Features
l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
l Range from 16A 800A AC-1
l Wide operating band up to 100A AC-1

MCX 22 MCX 34 MCX 47 AuXC-1000L AuXC-1000


AC-1 M.R.P. Std. M.R.P.
Rating Type Aux Pkg. Std. Pkg.
Size Cat. No. (`) Type Cat. No. (`)
(A) Contacts (Nos.) (Nos.)
Per Unit Per Unit
16 MCX 01 # CS97009 1025 10 AuXC-1000L ST80024OOOO 43770 1
25 MCX 02 # CS97010 1115 10 AuXC-1000 ST80230OOOO 52745 1
Fr 1
32 MCX 03 # CS97011 1175 10 Can be used along with , MCCBs, MCX contactors & Motorized
40 MCX 04 # CS97012 1830 10 Changeover switches

50 MCX 11 # CS97013 2280 1


Fr 2 63 MCX 12 # CS97014 4395 1
80 MCX 13 # CS97015 5960 1 Notes:
1) # Add on blocks can be ordered separately.
80 MCX 21 # CS97016 6645 1 2) For ordering MCX add-on aux contact blocks, please refer page No. 8
Fr 3 100 MCX 22 # CS97017 7420 1 3) For ordering MCX surge suppressor and MIL kit, please refer page No. 9
4) For Ordering Suffix, please refer page No. 9, Table A
130 MCX 23 # CS97018 9280 1 5) Std. Coil Voltage: MCX - 220V, 240V and 415V 50Hz
130 MCX 31 2 NO + 2 NC CS97019 11060 1 6) *Ordering Suffix for MCX 21 / 22 / 23; FOOO - 240V AC, ROOO - 415V AC
160 MCX 32 2 NO + 2 NC CS97020 15260 1 7) Mounting of side add-on aux. contact block is not recommended for
Fr 4 mechanically interlocked MCX 11/12/13 contactors
200 MCX 33 2 NO + 2 NC CS97021 18240 1
255 MCX 34 2 NO + 2 NC CS97022 19355 1
325 MCX 41 2 NO + 2 NC CS97023 35240 1
360 MCX 42 2 NO + 2 NC CS97024 38225 1
400 MCX 43 2 NO + 2 NC CS97025 45170 1
Fr 5 500 MCX 44 2 NO + 2 NC CS97026 56685 1
600 MCX 45 2 NO + 2 NC CS97027 68185 1
700 MCX 46 2 NO + 2 NC CS97028 80025 1
800 MCX 47 2 NO + 2 NC CS94291 103155 1

Control Relays (Auxiliary Contactors)


Type MX0 AC Control Contactor - MO0
Features
l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 New Features
l Available with AC or DC control in 45mm width l MO0 in 5 pole design in 45mm width
l Inbuilt Surge Suppressor in MX DC l Same add-on aux. contact block in MO0 as of
MX0 40E MO0 AC
MO power contactors
M.R.P. Std. M.R.P. Std.
Rated Description Pkg. Rated Description Pkg.
Cat. No. (`) Cat. No. (`)
Current (Nos.) Current (Nos.)
Per Unit Per Unit
For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz

MX0 40E (4 NO) CS94018 810 10 MO0 41E (4 NO + 1 NC) CS94825 985 10
New MO0 32E (3 NO + 2 NC) CS94826 985 10
MX0 31E (3 NO + 1 NC) CS94019 810 10 AC-15
4A MO0 23E (2 NO + 3 NC) CS94827 985 10
AC-15 MX0 22E (2 NO + 2 NC) CS94020 810 10 at 415V
4A MO0 14E (1 NO + 4 NC) CS94828 985 10
at 415V MX0 13E (1 NO + 3 NC) CS94041 810 10
Note: 7NC & above combination is not recommended for MO0
MX0 04E (4 NC) CS94042 810 10
For DC control std. Coil Voltage - 24, 110, 220V
MX0 40E (4 NO) CS94027 1090 10 DC Control Contactor - MN0
MN0 DC 22E
MX0 31E (3 NO + 1 NC) CS94028 1090 10
M.R.P. Std.
AC-15 Rated Description Pkg.
MX0 22E (2 NO + 2 NC) CS94029 1090 10 Cat. No. (`)
4A Current (Nos.)
Per Unit
at 415V MX0 13E (1 NO + 3 NC) CS94043 1090 10
For DC control std. Coil Voltage - 24, 110, 220V
MX0 04E (4 NC) CS94044 1090 10
MN0 40E (4 NO) SS94665 1580 10
Notes:
MN0 31E (3 NO + 1 NC) SS94666 1580 10
1) For Ordering Suffix, please refer page No. 9, Table A AC-15
2) 5 NC & above combinations are not recommended for MX0 DC Control Contactors 4A MN0 22E (2 NO + 2 NC) SS94667 1580 10
3) 1 NO + 3 NC, 4 NC add on block combinations are not recommended for MX0 DC at 415V
Control Contactors. For Example, In MX0 DC control Contactors, 4NO + 4NC MN0 13E (1 NO + 3 NC) SS94668 1580 10
combination can be achieved with 2NO + 2NC aux contactor and 2NO + 2NC MN0 04E (4 NC) SS94669 1580 10
add on block and not with 4NO standalone contactor and 4NC add on block
6 L&T, ESP 01.01.2015
Capacitor Duty Contactors
Capacitor Duty Contactors - Type MO C

MO C25 MO C50 MO C80


kVAr Rating Built-in M.R.P. Std. Features
Size @ 415V, Type Auxiliary Cat. No. (`) Pkg. l MO C Range available from 8.5 - 80 kVAr
3Ph, 50Hz Contacts Per Unit (Nos.)
l Delatching auxiliary contacts
1NO CS96320 1790 1
8.5 MO C8.5 l Encapsulated resistor assembly
1NC CS96337 1790 1 l Separate termination for damping resistors
1NO CS96321 2035 1 l Lug less termination
12.5 MO C12.5
1NC CS96338 2035 1 l Low pick-up VA
l Standard accessories throughout the range in line with
1NO CS90019 2870 1
Fr 1 15 MO C15 MO contactor
1NC CS90020 2870 1
l RoHS compliant
1NO CS90021 3280 1
20 MO C20
1NC CS90022 3280 1
1NO CS96322 3720 1
25 MO C25
1NC CS96339 3720 1
For Reactive Power Management Solutions,
1NO CS96323 6880 1
33.5 MO C33.5 please refer page No. 61-63
1NC CS96340 6880 1
Fr 2
1NO CS96324 10140 1
50 MO C50
1NC CS96341 10140 1 Note :
1) For ordering add-on aux. contact block, please refer page No. 8
1NO CS96325 12300 1 2) For ordering suffix, please refer page No. 9, Table A
70 MO C70
1NC CS96342 12300 1 3) For ordering spare coils, please refer page No. 10
Fr 3 4) For ordering spreader link kit of MO C 8.5-25, please refer page No. 9
1NO CS96326 13450 1 5) Standard coil voltage : 240V, 50Hz
80 MO C80
1NC CS96343 13450 1

Definite Purpose Contactors


Type MU Type MK1

MU 1 MU 2 MK 1
AC3 M.R.P. Std. AC3 Motor Output M.R.P. Std.
Rating Type Cat. No. (`) Pkg. Type Rating 3 Phase Pkg.
415V, 50Hz Cat. No. (`)
(A) Per Unit (Nos.) (A) Per Unit (Nos.)
HP KW
16A MU 1 CS94007 1600 10
MK 1 15A 7.5 5.5 SS95200 1015 10
25A MU 2 CS94008 2170 10
For Overload Relays type MK1, please refer page No. 13
For Overload Relays type MU refer page No.13 For Ordering Suffix, please refer page No. 9, Table A
For Ordering Suffix please refer page No. 9, Table A (For 360V wide band, Ordering Suffix - SOOO)

Single Pole Contactors - Type MR


Features
l Wide and chatter free operating band
l High AC-1 rating for single phase applications

MR 11W MR 13 MR 11NW
(Wide band coil) SPN (Wide band coil)

AC3 Rating M.R.P. Std.


Type Cat. No. (`) Pkg.
(A) (Nos.)
Per Unit
25A MR 11W CS94176 675 10
25A MR 11NW CS94178 725 10
40A MR 13 CS94992 740 40
Ordering Suffix BOOO - 240V, 50Hz

L&T, ESP 01.01.2015 7


Accessories - Add-on Auxiliary Contact Blocks
MNX MNX MO MO MDX MCX MCX
ML MX MX0 MN0 MO0 MO C MR MU
9-80 95-650 9-18 25-110 9-110 01-23 31-47
Front add-on possible Yes No Yes Yes No Yes Yes Yes No Yes Yes Yes No Yes No
Side add-on possible Yes Yes No Yes Yes No Yes Yes Yes No No No Yes No Yes

Note: 1) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
2) Accessories are common for MNX 2P & MNX 3P

Front Mounting Add-on aux. Contact Block

MNX / MCX MO / MO0 MDX Front MX Front MN0 Front


Front Add-on Front Add-on Add-on Add-on Add-on
aux. contact Block aux. contact Block aux. contact Block aux. contact Block aux. contact Block
Suitable for
Front M.R.P. M.R.P. M.R.P. M.R.P. M.R.P.
Mounting MNX 9-80 / MO 9-110 / MDX MX MN0
(`) (`) (`) (`) (`)
MCX 01-23 MO0 9-110 0/6/9/12 DC
Per Unit Per Unit Per Unit Per Unit Per Unit
4 NO CS94112 425 CS94594 425 CS94033 370 SS94083 390
3 NO + 1 NC CS94113 425 CS94595 425 CS94034 370 SS94084 390
2 NO + 2 NC CS94114 425 CS94596 425 CS96569 525 CS94035 370 SS94085 390
1 NO + 3 NC CS94115 425 CS94597 425 CS94036 370 SS94086 390
4 NC CS94116 425 CS94598 425 CS94037 370 SS94087 390
2 NO CS94117 290 CS94591 290 CS94030 240 SS94080 260
1 NO + 1 NC CS94118 290 CS94592 290 CS96568 305 CS94031 240 SS94081 260
2 NC CS94119 290 CS94593 290 CS94032 240 SS94082 260
1 NO CS94120 140 CS94585 140 SS94715 130
CS96586 170
1 NC CS94121 140 CS94586 140 SS94716 130

Side Mounting Add-on aux. Contact Block

MNX/MCX MO/MO C MDX


Side Add-on Left Add-on Side Add-on
aux. contact Block aux. contact Block aux. contact Block
Suitable for
Side M.R.P. M.R.P. M.R.P. M.R.P. M.R.P.
Mounting MNX 9-40 / MNX 45-80 / MNX 95-650 / MO 25-110/
Aux Contact (`) (`) (`) (`) MDX 9-110 (`)
MCX 01-04 MCX 11-23 MCX 31-47 MO C 8.5-80
Per Unit Per Unit Per Unit Per Unit Per Unit
First left 1 NO + 1 NC CS94220 425 CS94201 455 CS94205 515 CS94580 425
ST94985 630
First Right 1 NO + 1 NC CS94221 425 CS94202 455 CS94206 515 CS94581 425
Second Left 1 NO + 1 NC CS94203 455 CS94207 515 CS94582 425
Second right 1 NO + 1 NC CS94204 455 CS94208 515 CS94583 425

Note: Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors

Side Mounting Add-on aux. Contact Block - ML Add-on aux. Contact Block - MR & MU

ML Add-on
aux. contact Block MR 1NO

Suitable for M.R.P. Std.


For Contacts
Side Description Cat. No. (`) Pkg.
M.R.P. M.R.P. Contactor Type
Mounting Per Unit (Nos.)
Aux Contact ML 4/6 (`) ML 10/12 (`)
Per Unit Per Unit Top add-on single pole MR 1 NO CS94179 175 10

Left 1 NO + 1 NC SS91494 540 Side mounted auxiliary 1 NO + 1 NC SS94072 150 10


MU 1 / MU 2
contact block 1NC SS94074 125 10
Right 1 NO + 1 NC SS91474 555

Note: Ordering Suffix for Add-on aux. contact blocks : OOOO

8 L&T, ESP 01.01.2015


Accessories - Surge Suppressors
For MX, MNX, MDX & MCX For MN0

MNX S1 MNX S3 MNX S4 MX - S1 MN - S1


M.R.P. M.R.P. Std.
For Contactor Cat. No. (`) Type Cat. No. (`) Pkg.
Per Unit Per Unit (Nos.)
MX 06 to MX 12 / MX 0 AC CS94039* 375 MN0 DC SS94781 400 1
MNX 9 - 40 / MCX 01 - 04 CS94166* 390
MNX 45 - 80 / MCX 11 - 23 CS94163* 425 Ordering Suffix: 24-48VDC : 5OOO
110-220VDC : 2OOO
MNX 95 - 250 / MCX 31 - 34 CS94164# 1405
MNX 265 - 400 / MCX 41 - 44 CS94165# 1900
MDX 50 - 110 CS96571** 360
Ordering Suffix * 110-240V: BOOO, 415V: DOOO ** : OOOO
# 110V: AOOO, 220-240V: BOOO, 360-525V: DOOO
- MX DC has in-built surge suppressor

Accessories - Mechanical Interlock Kits & Spreader Link Kit


Mechanical Interlock Kit for MX, MO, MDX, MO Spreader Link Kit
MNX & MCX

MNX M1 MCX M3 MO MI Kit MX-M1


(MNX 9-40) (MCX 21-22) (MO 9-110) (MX0 / MX06-MX09)

M.R.P. M.R.P.
For Contactor Cat. No. (`) For Contactor Cat. No. (`)
Per Unit Per Unit
MX 06 to MX 12 / MX 0 CS94038 360 MO 25-45 / MO C 8.5-25 CS94274OOOO 365
MO 9 - 110* CS94584 465
Note: 1) Spreader Link Kit consists of six terminals
MDX 9 - 38 CS96572 400 2) Use above Spreader Link when using MO 45/MO C 25 with
MDX 50 - 110 CS96573 1225 16 sq mm cable
MNX 9 - 40 CS94126 400
MNX 45 - 80 CS94197 1725
MNX 95 - 140 CS94198 2680
MNX 185 - 250 CS94199 3055
MNX 265 - 650 CS94200 3465
MCX 01 - 04 CS94126 400
New MCX 11 - 13 ST50540 755
MCX 21 - 23 CS93095 2735
MCX 31 - 34 SS94992 2825
MCX 41 - 47 CS94301 4665
Note 1) Ordering Suffix for Mechanical Interlock Kits : OOOO
2) * MO MIL Kit contains inbuilt 2 NC Contacts
3) Mounting of side add-on aux. contact block is not recommended for mechanically
interlocked MCX 11/12/13 contactors
4) MIL kit for MNX 45-80 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NC
5) MIL kit for MCX 21/22/23 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NC

Ordering Suffix for Standard Coil Voltages


Table A
Ordering Suffix for Standard Coil Voltages

AC Control DC Control*
Voltage (V) Suffix Voltage (V) Suffix
24 GOOO 24 4OOO
110 AOOO 48 5OOO
220 KOOO 110 1OOO
240 BOOO 220 2OOO
415 DOOO
440 POOO

Note: 1) * For MX DC, MDX, MX0 DC & MN0 DC


2) For other coil voltages please contact nearest branch office

L&T, ESP 01.01.2015 9


Spares
Spare Contact Kit and Spare Coil Spare Contact Kit and Spare Coil

ML Spare Kits MNX Spare Coils MCX Spare Kits


Spare Contact kit Spare Coil
M.R.P. M.R.P.
ML Spare Coils Type Cat. No. (`) Cat. No. (`)
Per Unit Per Unit
Spare Contact kit Spare Coil New MO 9 (1 NO + 1 NC) CS94843 490
M.R.P. M.R.P. New MO 12 (1 NO + 1 NC) CS94844 635 CS94841 440
Type Cat. No. (`) Cat. No. (`)
Per Unit Per Unit New MO 18 (1 NO + 1 NC) CS94845 695
MU 1 CS94010 580 MO 9 CS96380 490
CS94009 440
MU 2 CS94011 1025 MO 12 CS96381 635
ML 1.5 SS95305 1415 SS90873 590 MO 18 CS96382 695

MO Contactors
ML 2 SS95307 2215 MO 25 CS96383 795 CS96317 440
SS90545 960
ML 3 SS95309 3765 MO 32 CS96384 1585
ML 4 SS95311 5875 MO 40 CS96385 2365
SS91258 1840
ML 6 SS95313 10240 MO 45 CS96386 2745
ML 10 SS95315 20090 MO 50 CS96387 2805
SS91011 4025
ML 12 SS95317 24900 MO 60 CS96388 3315 CS96318 1390
MR - - CS94102 370 MO 70 CS96389 3920
MO 0 AC - - CS94841 440 MO 80 CS96390 4690
MN 0 AC - - SS94191 470 MO 95 CS96391 5730 CS96319 2205
MN 0 DC - - SS94651 865 MO 110 CS96392 6920
MNX 9 CS94123 490
MNX 12 CS94124 635
MNX 18 CS94125 695
MO C Spare Coils MNX 22 CS94269 715 CS94105 440
M.R.P. MNX 25 CS94127 795
Type Cat. No. (`)
MNX 32 CS94128 1485
Per Unit
MO C8.5 - 25 CS96317 440 MNX 40 CS94147 2365
MO C33.5 - 50 CS96318 1390 MNX 45 CS94149 2745
MO C70 - 80 CS96319 2205 MNX 50 CS94150 2805
CS94192 1390
MNX Contactors

MNX 70 CS94151 4040


MNX 80 CS94152 5135
MNX 95 CS94153 5950
MNX 110 CS94154 7355 CS94196 2205

Front housing & Moving bridge kit and MNX 140 CS94155 10195
MNX 185 CS94156 12215
Combination coil with timer for 13870 CS94194 4010
MNX 225 CS94157
ML contactor MNX 250 CS90310 15160
MNX 265 CS94159 16880
MNX 300 CS90283 18590
CS94195 4695
MNX 325 CS94160 20495
MNX 400 CS94161 26855
MNX 550 CS94162 35410
CS94193 14675
Front housing and moving bridge kit MNX 650 CS96336 47455
M.R.P. MCX 01-04 - - CS94105 440
Type Cat. No. (`)
Per Unit MCX 11 CS94077 1590
ML 1.5 ST28734 425 MCX 12 CS94078 2615 CS94009 440
ML 2/ ML 3 ST23866 585 MCX 13 CS90307 3655
ML 4/ ML 6 ST28735 1060 MCX 21 CS94330 3855
Combination coil with timer MCX 22 CS94331 4440 ST91291* 1390
M.R.P. MCX 23 CS90078 5555
MCX Contactors

Type Cat. No. (`) MCX 31 CS94081 6440


Per Unit
ML 2 SS90650 2005 MCX 32 CS94082 8360
CS94196 2205
MCX 33 CS94083 10510
Note :
MCX 34 CS94084 11505
1) Ordering Suffix for Spare Contact kit - OOOO
MCX 41 CS94295 20075
2) For Spare Coil Ordering Suffix refer page No. 9, Table A
MCX 42 CS94296 25475
CS94195 4695
MCX 43 CS94297 28575
MCX 44 CS94298 35005
MCX 45 CS94299 37735
MCX 46 CS94300 43420 CS94193 14675
MCX 47 CS90308 55975
* Ordering Suffix for 240V AC - FOOO, 415V AC - ROOO

10 L&T, ESP 01.01.2015


Thermal Overload Relays
Type MN Type RTO
Features Features
l Available in 3 frame sizes from 0.2-570 A l Ambient temperature compensated upto 55oC
l Ambient temperature compensated up to 55C l Built-in Single Phasing protection
l Built-in Single Phasing protection l Manual and auto reset mode
l Manual and auto reset mode l Front access to START and STOP/RESET buttons
l Sealable in OFF condition

MN 2 MN 5 MN 12 MN 12L RTO 1 RTO 2 RTO 3


Type of M.R.P. Std. Type of M.R.P. Std.
Relay Range Relay Range
Mounting Cat. No. (`) Pkg. Mounting Cat. No. (`) Pkg.
(A) (A)
(Operation) Per Unit (Nos.) (Direct) Per Unit (Nos.)
MN 2 RTO - 1
0.2 - 0.33 SS94141OOEO 1170 10 0.23 - 0.41 CS96355OOFO 1315 10
0.3 - 0.5 SS94141OOGO 1170 10 0.31 - 0.55 CS96355OOGO 1315 10
0.45 - 0.75 SS94141OOJO 1170 10 0.55 - 0.85 CS96355OOJO 1315 10
0.6 - 1 SS94141OOKO 1170 10 0.78 - 1.2 CS96355OOLO 1315 10
(Directly
Operated) 0.9 - 1.5 SS94141OOMO 1170 10 1.2 - 2.0 CS96355OONO 1315 10
1.4 - 2.3 SS94141OOPO 1170 10 1.9 - 2.8 CS96355OOPO 1315 10
Direct 2 - 3.3 SS94141OOQO 1180 10 2.4 - 3.6 CS96355OOQO 1325 10
mounting 3-5 SS94141OOSO 1180 10 3.5 - 5.2 CS96355OOSO 1325 10
on 4.5 - 7.5 SS94141OOUO 1180 10 4.6 - 6.7 CS96355OOTO 1325 10
MNX 9 - 40 MO 9 - 45
6 - 10 SS94142OOVO 1180 10 6.7 - 9.7 CS96355OOVO 1340 10
9 - 15 SS94142OOBO 1215 10 8.5 - 12.5 CS96355OOAO 1380 10
14 - 23 SS94144OODO 1295 10 12.5 - 18.5 CS96356OOCO 1460 10
20 - 33 SS94145OOEO 1925 10 17 - 25.5 CS96356OODO 1460 10
24 - 40 SS94145OOFO 1925 10 25 - 37 CS96356OOEO 2185 10
MN 5 35 - 45 CS96356OOGO 2185 10

(Directly 9 - 15 SS94135OOBO 2190 10 RTO - 2


Operated) 14 - 23 SS94135OODO 2190 10 10.5 - 16 CS96366OOBO 2420 1
20 - 33 SS94136OOEO 2210 10 15 - 21 CS96366OOCO 2420 1
Direct
Mounting on 30 - 50 SS94136OOGO 2530 10 New 20 - 31 CS96366OOEO 2470 1
MO 50 - 70
MNX 45 - 80 45 - 75 SS94137OOJO 3540 10 30 - 43 CS96366OOFO 2875 1

66 - 110 SS94137OOKO 3775 10 40 - 57 CS96366OOSO 3570 1

MN 12 50 - 75 CS96367OOJO 3985 1

28 - 46.5 SB94211OOGO 6405 1 RTO - 3


42 - 69 SS94138OOHO 6405 1 29-38 CS96303OOQO 4200 1
(CT Operated)
New 37-49 CS96304OOGO 4500 1
60 - 100 SS94138OOKO 6405 1 MO 80 - 110
90 - 150 6405 1 47-62 CS96312OOTO 4500 1
Separate SS94138OOMO
Mounting 60-78 CS96313OOJO 5200 1
135 - 225 SS94138OOPO 6920 1
75 - 110 CS96314OOKO 6015 1
180 - 300 SS94139OOQO 7945 1
270 - 450 SS94139OORO 8650 1
MN 12L #
42 - 69 SS94127OOHO 10105 1
(CT Operated) 60 - 100 SS94127OOKO 10105 1
90 - 150 SS94127OOMO 10105 1
Separate
135 - 225 SS94127OOPO 10105 1
Mounting
180 - 300 SS94127OOQO 10105 1 Modular Load Feeder
340 - 570 SS94127OOSO 10105 1 RTO Relays can be directly mounted onto MO contactors. This along
# For motors with longer starting time (Trip class 30) with the standardized accessories of MO provides you a complete
modular feeder solution.

Mini Motor Protection Relay


Features Aux. Supply: 240 V AC Aux. Supply: 110 V AC
l Selectable trip class 10A, 10, 20 and 30. Thermal M.R.P. M.R.P.
Model O/L Range
l In-built CT (1A - 88A) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit
l Test facility 1-2.75 MPR300BE010 5700 MPR300BB010 5700
l Protection
2-5.5 MPR301BE020 5700 MPR301BB020 5700
- Thermal Overload - Locked Rotor
4-11 MPR302BE040 5700 MPR302BB040 5700
- Single phasing - Earth Fault MPR300
8-22 MPR303BE080 5700 MPR303BB080 5700
- Current unbalance - Under current
16-44 MPR304BE160 5700 MPR304BB160 5700
- Phase sequence reversal
32-88 MPR305BE320 5700 MPR305BB320 5700
Note : For comprehensive Relays portfolio kindly refer page No. 66

12 L&T, ESP 01.01.2015


Thermal Overload Relays
Type MX-R0 Type ML

Features
l Direct mounting on MX contactor
l Built-in single phasing protection

MX - R0 ML

Type of M.R.P. Std. Type of M.R.P. Std.


Relay Range Relay Range
Mounting Cat. No. (`) Pkg. Mounting Cat. No. (`) Pkg.
(A) (A)
(Operation) Per Unit (Nos.) (Operation) Per Unit (Nos.)
0.1 - 0.16 ST94074OOBO 890 10 ML 1
0.16 - 0.24 ST94074OODO 890 10 0.15 - 0.25 SS91858OODO 1645 10
0.22 - 0.33 ST94074OOEO 890 10 0.25 - 0.4 SS91858OOFO 1645 10
(Directly
0.3 - 0.45 ST94074OOGO 890 10 Operated) 0.4 - 0.65 SS91858OOHO 1645 10
(Directly
Operated) 0.45 - 0.67 ST94074OOHO 890 10 0.6 - 1 SS91858OOKO 1645 10
0.67 - 1.0 ST94074OOKO 890 10 1 - 1.6 SS91858OOMO 1645 10
1.0 - 1.5 ST94074OOMO 890 10 1.5 - 2.5 SS91858OOPO 1645 10
Direct 2.5 - 4 SS91858OORO 1645 10
1.4 - 2.1 ST94074OONO 890 10
Direct Mounting on
1.8 - 2.7 ST94074OOPO 890 10 4 - 6.5 SS91858OOTO 1645 10
Mounting on ML 1.5 Contactors
2.4 - 3.6 ST94074OOQO 890 10 6 - 10 SS91858OOVO 1645 10
MX Contactors
3.5 - 5 ST94074OOSO 890 10 10 - 16 SS91858OOBO 1645 10
4.0 - 6.0 ST94074OOTO 890 10 (Directly ML 2 / ML 3
5.5 - 8.5 ST94074OOUO 890 10 Operated) 9 - 14 SS91859OOAO 2430 2
8.5 - 12.5 ST94074OOVO 890 10 13 - 21 SS91859OOCO 2430 2
Direct
Mounting on 20 - 32 SS91859OOEO 2430 2
ML 2/3 Contactors 28 - 42 SS91859OOFO 2430 2

Type MK1 Type MU

MK1 MU1 MU2

Type of M.R.P. Std. Type of M.R.P. Std.


Relay Range Relay Range
Mounting Cat. No. (`) Pkg. Mounting Cat. No. (`) Pkg.
(A) (A)
(Operation) Per Unit (Nos.) (Operation) Per Unit (Nos.)

0.6 - 1 SS90035OOKO 745 10 MU1


(Directly
1 - 1.6 SS90035OOMO 745 10 4 - 6.5 SS96557OOTO 990 1
Operated)
1.5 - 2.5 SS90035OOPO 745 10 6 - 10 SS96557OOVO 990 1
(Directly
2.5 - 4 SS90035OORO 745 10 Operated) MU2
4 - 6.5 SS90035OOTO 745 10 9 - 14 SS95979OOAO 1080 1
Direct 6 - 10 SS90035OOVO 745 10 Direct 13 - 21 SS95979OOCO 1150 1
Mounting on 9 - 14 SS90035OOAO 745 10 Mounting on 15 - 25 SS95979OODO 1250 1
MK1 Contactors MU Contactor
11 - 18 SS90036OOCO 790 10 20 - 32 SS95979OOEO 1395 1
13 - 22 SS91888OODO 835 10 24 - 38 SS95979OOGO 1495 1
28 - 42 SS95979OOFO 1650 1

L&T, ESP 01.01.2015 13


Accessories for Thermal Overload Relays
Accessories for Thermal Overload Relays Relay Reset Cord for MN2 Relay

Relay Mounting Kit Kit for Mounting MN5 Relay Din Rail Mounting Kit 400 mm 650 mm 900 mm 1200 mm
MN2 Relay
M.R.P. Std. M.R.P. Std.
Description Cat. No. (`) Pkg. Description Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Push button unit for MK 1 / ML Relays SS90004 90 1 MN2 Relay reset cord - 400mm SB94207OOOO 565 1
Push button extn. unit for MN 2 Relays SS94968 40 100
MN2 Relay reset cord - 650mm SB94208OOOO 595 1
Kit for Mounting MN 2 Relay on
SS94701 145 50
ML 1.5 contactor MN2 Relay reset cord - 900mm SB94209OOOO 650 1
Kit for Mounting MN 2 Relay
SS94700 145 50 MN2 Relay reset cord - 1200mm SB94210OOOO 730 1
separately (Direct Mounting Type)

Kit for Mounting MN 5 Relay on


SS94638 220 20
MNX 95 / 110 / 140 contactor

Kit for Mounting MN 5 Relay on


ML 2 / ML 3 contactor
SS94151 160 20 Separate Mounting Kit
Kit for Mounting MN5 Relay on for RTO Relay
SS94152 205 20
ML 4 / ML 6 contactor
M.R.P. Std.
DIN Rail Mounting Kit Relay on Description Pkg.
SS91887 110 50 Cat. No. (`)
MN 2 Relay Per Unit (Nos.)

RTO-1 Relay Separate Mounting Kit CS96335OOOO 210 1

RTO-2 Relay Separate Mounting Kit CS96306OOOO 500 1

RTO-3 Relay Separate Mounting Kit CS96307OOOO 750 1

Control Accessories
Actuator Units Type TK3* Push Button Pendants*
6A, 415V, 50 Hz (Suitable for 30.5mm Cutout Dia.) 6A, 415V, 50 Hz
M.R.P. Std M.R.P. Std
Description Cat. No. (`) Pkg. Description Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)

Selector actuator - 2 position SS91516 485 30 With 2 push buttons SS90502 1130 30
(black only) With 4 push buttons SS90504 2095 30
Selector actuator - 3 position With 6 push buttons SS90506 2815 30
(black only) SS91517 485 30

Mushroom push button actuator Ordering Suffix is OOOO


SS91518 295 30
(red, green or black)
Shrouded push button actuator
(red, black, green, yellow, blue SS91519 215 30
or grey)

Unshrouded push button actuator


(red, black, green, yellow, blue SS91520 215 30
or grey)

Key actuator - lockable in 1 position SS91522 # 660 30

Key actuator - lockable in both SS91521 # 30


positions 660

* Available till stock last


Element with 2 fixing screws SS90375 # 240 100

Ordering Suffix for Colour


To order Control Accessories, please specify
Black OAOO
Red
Type, Cat no. & Ordering Suffix for color
OBOO
Green OCOO
Yellow ODOO
Blue OEOO
Grey OFOO
# OOOO

14 L&T, ESP 01.01.2015


Motor Protection Circuit Breakers
Rocker Type Rotary Type Rotary Type
l MOG-S1: upto 13A l MOG-H1M: upto32A l MOG-H1: upto 32A
l Short circuit + Overload protection l MOG-H2M: 32A-63A l MOG-H2: 32A-63A
l Icu=100kA upto 10A & Icu=50kA for 13A l Short circuit protection l Short circuit + Overload protection
l Icu=100kA upto 13A & Icu=50kA from 16A-63A l Icu=100kA upto 13A & Icu=50kA from 16A-63A

R
Y
B
Compact
Short circuit protection
Circuit Wide Range
Over current protection Breaker
High breaking capacity MPCB
Overload + Short
Short circuit protective circuit protection

coordination

Reduction in wiring work


Overload protection High switching durability
Contactor
Phase loss protection Padlocking feature available
Thermal even without external
Wide range of current No separate
Overload operating handle overload relay
adjustment dial Relay
MPCB Stand alone motor protection
Ambient temperature
Common accessories Motor
compensation

Type MOG-S1 (Rocker Type) Type MOG-H1M (Rotary Type) - Frame 1


(ROM cannot be fitted with MOG - S1) With short circuit protection only
With short circuit & overload protection

Recommended Thermal Recommended


M.R.P. Std. Short Circuit M.R.P. Std.
Rating Motor Rating Release Rating Motor Rating
Cat. No. (`) Pkg. Release Cat. No. (`) Pkg.
(A) at 415V, 3-Ph, range (A) at 415V, 3-Ph,
50Hz (KW) (A) Per Unit (Nos.) 50Hz (KW)
(A) Per Unit (Nos.)

0.16 - 0.1 - 0.16 ST41889OOOO 2340 1 0.16 - 2.1 ST41923OOOO 2190 1


0.25 0.06 0.16 - 0.25 ST41890OOOO 2340 1 0.25 0.06 3.3 ST41924OOOO 2190 1
0.40 0.09 0.25 - 0.40 ST41891OOOO 2340 1 0.40 0.09 5.2 ST41925OOOO 2190 1
0.63 0.12 0.40 - 0.63 ST41892OOOO 2445 1 0.63 0.12 8.2 ST41926OOOO 2940 1
1.00 0.25 0.63 - 1.00 ST41893OOOO 2445 1 1.00 0.25 13 ST41927OOOO 2940 1
1.60 0.55 1.00 - 1.60 ST41894OOOO 2505 1 1.60 0.55 20.8 ST41928OOOO 2940 1
2.50 0.75 1.60 - 2.50 ST41895OOOO 2505 1 2.50 0.75 32.5 ST41929OOOO 2940 1
4.00 1.50 2.50 - 4.00 ST41896OOOO 2570 1 4.00 1.50 52 ST41930OOOO 3100 1
6.30 2.20 4.00 - 6.30 ST41897OOOO 2585 1 6.30 2.20 81.9 ST41931OOOO 3100 1
10.00 4.00 6.30 - 10.00 ST41898OOOO 2585 1 10.00 4.00 130 ST41932OOOO 3205 1

13.00 5.40 9.00 - 13.00 ST41899OOOO 2855 1 13.00 5.40 169 ST41933OOOO 3330 1
16.00 7.50 208 ST41934OOOO 3385 1
Breaking capacity: Icu = 100kA upto 10A & Icu = 50kA for 13A
20.00 9.00 260 ST41935OOOO 3625 1
25.00 12.50 325 ST41936OOOO 4385 1
32.00 15.00 416 ST41937OOOO 6015 1

Breaking capacity: Icu = 100kA upto 13A & Icu = 50kA from 16A - 32A

16 L&T, ESP 01.01.2015


Motor Protection Circuit Breakers
Type MOG-H1 (Rotary Type) - Frame1 Type MOG-H2 (Rotary Type) - Frame 2
With short circuit & overload protection With short circuit & overload protection

Recommended Thermal Recommended Thermal


M.R.P. Std. M.R.P. Std.
Rating Motor Rating Release Rating Motor Rating Release
Cat. No. (`) Pkg. Cat. No. (`) Pkg.
(A) at 415V, 3-Ph, range (A) at 415V, 3-Ph, range
Per Unit (Nos.) Per Unit (Nos.)
50Hz (KW) (A) 50Hz (KW) (A)
0.16 - 0.1 - 0.16 ST41904OOOO 2750 1 32.00 15.00 24.00 - 32.00 ST41919OOOO 9470 1
0.25 0.06 0.16 - 0.25 ST41905OOOO 2885 1 40.00 20.00 28.00 - 40.00 ST41920OOOO 9590 1
0.40 0.09 0.25 - 0.40 ST41906OOOO 2885 1 50.00 25.00 35.00 - 50.00 ST41921OOOO 10540 1
0.63 0.12 0.40 - 0.63 ST41907OOOO 3105 1 63.00 34.00 45.00 - 63.00 ST41922OOOO 11220 1
1.00 0.25 0.63 - 1.00 ST41908OOOO 3105 1 Breaking capacity: Icu = 50kA from 32A - 63A
1.60 0.55 1.00 - 1.60 ST41909OOOO 3110 1
2.50 0.75 1.60 - 2.50 ST41910OOOO 3110 1 Type MOG-H2M (Rotary Type) - Frame 2
4.00 1.50 2.50 - 4.00 ST41911OOOO 3170 1
With short circuit protection only
6.30 2.20 4.00 - 6.30 ST41912OOOO 3230 1
10.00 4.00 6.30 - 10.00 ST41913OOOO 3330 1
13.00 5.40 9.00 - 13.00 ST41914OOOO 3620 1
16.00 7.50 11.00 - 16.00 ST41915OOOO 4000 1
20.00 9.00 14.00 - 20.00 ST41916OOOO 4315 1
Recommended
25.00 12.50 19.00 - 25.00 ST41917OOOO 4695 1
Rating Motor Rating Short Circuit M.R.P. Std.
at 415V, 3-Ph, Release Cat. No. (`) Pkg.
32.00 15.00 24.00 - 32.00 ST41918OOOO 7325 1 (A)
50Hz (KW) (A) Per Unit (Nos.)
Breaking capacity: Icu = 100kA upto 13A & Icu = 50kA from 16A - 32A
32.00 15.00 416 ST41938OOOO 7730 1
40.00 20.00 520 ST41939OOOO 7730 1
50.00 25.00 650 ST41940OOOO 9430 1
63.00 34.00 819 ST41941OOOO 9430 1
Breaking capacity: Icu = 50kA from 32A - 63A

Accessories for MOG

Short Circuit Auxiliary + Alarm External Shunt Trip MPCBs with bus bar Connecting 3 Phase Feed
Alarm Operating Handle connection Busbar link in terminal
M.R.P. Std.
M.R.P. Std. Description Cat. No. (`) Pkg.
Mounting Description Cat. No. (`) Pkg. Per Unit (Nos.)
Position Per Unit (Nos.)
* Connecting Busbar link
F1/F2 Auxiliary Contact Front mtg. 1NO ST41942OOOO 480 10 2 MPCB 45 mm width w/o acc ST41957OOOO 590 5
F1/F2 Auxiliary Contact Front mtg. 1NC ST41943OOOO 480 10 3 MPCB 45 mm width w/o acc ST41958OOOO 650 5
L Auxiliary Contact Left side mtg. 2NO ST41944OOOO 590 1 4 MPCB 45 mm width w/o acc ST41959OOOO 705 5
Auxiliary Contact Left side mtg. 5 MPCB 45 mm width w/o acc ST41960OOOO 765 5
L ST41945OOOO 590 1
1NO + 1NC 2 MPCB 45 mm width with one acc 9 mm ST41961OOOO 690 5
L Auxiliary Contact Left side mtg. 2NC ST41946OOOO 575 1 3 MPCB 45 mm width with one acc 9 mm ST41962OOOO 750 5
F2 Trip Alarm Contact Front mtg. 1NO ST41947OOOO 765 10 4 MPCB 45 mm width with one acc 9 mm ST41963OOOO 805 5
F2 Trip Alarm Contact Front mtg. 1NC ST41948OOOO 765 10 5 MPCB 45 mm width with one acc 9 mm ST41964OOOO 865 5
L Auxiliary + Alarm Left side mtg. 2NO ST41949OOOO 815 1 2 MPCB 55 mm width w/o acc ST41966OOOO 1080 1
Short circuit alarm Left side mtg. 3 MPCB 55 mm width w/o acc ST41967OOOO 1230 1
L ST41950OOOO 815 1
1NO + 1NC 4 MPCB 55 mm width w/o acc ST41968OOOO 1480 1
R Shunt trip 24V DC ST41951OOOO 1330 1 2 MPCB 55 mm width with one acc 9 mm ST41969OOOO 1180 1
R Shunt trip 110V, 50Hz ST41952OOOO 1400 1 3 MPCB 55 mm width with one acc 9 mm ST41970OOOO 1330 1
R Shunt trip 230V, 50Hz ST42952OOOO 1400 1 4 MPCB 55 mm width with one acc 9 mm ST41971OOOO 1580 1
R Under Voltage release, 110V, 50Hz ST41953OOOO 1400 1 2 MPCB 55 mm width with two acc 18 mm ST41972OOOO 1380 1
R Under Voltage release, 415V, 50Hz ST41954OOOO 1400 1 4 MPCB 55 mm width with two acc 18 mm ST41973OOOO 1530 1
External operating handle, Feed in terminal for 45 mm width Busbar ST41965OOOO 690 1
- ST41955OOOO 1050 1
(Black) Frame 1 Feed in terminal for 55 mm width Busbar ST41974OOOO 1195 1
External operating handle, Bus bar safety cover 45 mm width Busbar ST41975OOOO 300 10
- ST41956OOOO 1050 1
(Black) Frame 2 Bus bar safety cover 55 mm width Busbar ST41976OOOO 325 10
*F1- Front left slot F2- Front right slot L- Left side R- Right side acc: Accessories

L&T, ESP 01.01.2015 17


Motor Starters
Direct-on-Line Starters Direct-on-Line Starters
in Sheet-Steel Enclosure Type MF, MK, MU & MB in Sheet-Steel Enclosure Type MN with Single Phase Protection
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

MF1 3-Ph MK1 MB1 MN 16 MN 45


Max. Motor Relay Max. Motor Relay M.R.P. Std.
M.R.P. Std.
Output at Max. Description Pkg. Output at Max. Description Cat. No. (`) Pkg.
Cat. No. (`)
415V, 3-Ph Range Per Unit (Nos.) 415V, 3-Ph Range Per Unit (Nos.)
HP kW (A) HP kW (A)
7.5 5.5 9 - 15 MF1 SS97210 1155 1 10.0 7.5 9 - 15 MN 16 DOL SS94351 3045 1
7.5 5.5 9 - 14 MK1 DOL SS96210 1870 1 15.0 11.0 14 - 23 MN 25 DOL SS94352 4655 1
7.5 5.5 11 - 18 MK1 DOL SS96211 1915 1 20.0 15.0 20 - 33 MN 32 DOL SS94353 7510 1
7.5 5.5 13 - 22 MK1 DOL SS96228 1960 1 30.0 22.5 30 - 50 MN 45 DOL SS94017 12845 1
10.0 7.5 15 - 25 MU1 DOL # SS95647 3275 1 45.0 33.5 45 - 75 MN 65 DOL SS94018 17595 1
10.0 7.5 14 - 23 MB1 DOL # SS95649 3200 1
15.0 11.0 24 - 38 MU2 DOL # SS95648 4390 1
15.0 11.0 20 - 33 MB2 DOL # SS95650 4295 1
For lower relay ranges, please refer Agricultural Electrical Products' price list. Direct-on-Line Starters
in Sheet-Steel Enclosure Type ML
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
Single Phase Starters
New

MF1 1-Ph MU-2P DOL


ML 1.5 ML 2 ML 3
Max. Motor Relay Std.
M.R.P.
Output at Max. Max. Motor Relay Std.
Description Cat. No. (`) Pkg. M.R.P.
230V, 1-Ph Range Output at Max. Description Cat. No. (`) Pkg.
Per Unit (Nos.)
HP kW (A) 415V, 3-Ph Range Per Unit (Nos.)
HP kW (A)
2.0 1.5 10.5 - 17.5 MF1 SS97227OOBO 860 1
15.0 11.0 20 - 32 ML 1.5 DOL SS91854 4725 1
3.0 2.2 12 - 20 MF1 SS97227OOCO 860 1
20.0 15.0 20 - 32 ML 2 DOL SS90702 7870 1
2 1.5 9-14 MU-2P CS90319KOAO 1390 1
30.0 22.5 28 - 42 ML 3 DOL SS90722 13390 1
2 1.5 11 - 18 MU-2P CS90319KOCO 1430 1
3 2.2 13 - 22 MU-2P CS90319KODO 1475 1

Semi-Automatic Star-Delta Starters Semi-Automatic Star-Delta Starters


in Sheet-Steel Enclosure Type MK, MU & MB in Sheet-Steel Enclosure Type ML
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

MK 1S MU 1S MB 2S ML 1.5S ML 2S
Max. Motor Relay Max. Motor Relay
M.R.P. Std. Output at M.R.P. Std.
Output at Max. Max.
Description Cat. No. (`) Pkg. Description Cat. No. (`) Pkg.
415V, 3-Ph Range 415V, 3-Ph Range
Per Unit (Nos.) Per Unit (Nos.)
HP kW (A) HP kW (A)
12.5 9.3 9 - 14 MK1 SASD SS96255 6125 1 25.0 18.5 13 - 21 ML1.5 SASD SS91856 10875 1
15.0 11.0 11 - 18 MK1 SASD SS96258 6170 1 35.0 26.0 20 - 32 ML2 SASD SS90707 19005 1
15.0 11.0 13 - 22 MK1 SASD SS96260 6215 1
15.0 11.0 13 - 21 MU1 SASD # SS95891 8205 1
15.0 11.0 14 - 23 MB1 SASD # SS95895 9215 1
30.0 22.5 20 - 32 MU2 SASD # SS95893 10370 1
30.0 22.5 20 - 33 MB2 SASD # SS95897 10910 1
For lower relay ranges, please refer Agricultural Electrical Products' price list.
Note: 1) # Type MU1 / MU2 consists of type MU Relay + MU1 / MU2 contactors
Type MB1 / MB2 consists of type MN Relay + MU1 / MU2 contactors
2) For Ordering Suffix please refer table B page No. 20

18 L&T, ESP 01.01.2015


Motor Starters
Fully Automatic Star-Delta Starters Spares for MK1 Starters
in Sheet-Steel Enclosure Type MN
with Single Phase Protection feature
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

Aux contact Spare Combination Push


MN 16F block coil coil button unit

Max. Motor Relay Std.


Std. M.R.P.
Output at Max. M.R.P. Description Pkg.
Description Pkg. Cat. No. (`)
415V, 3-Ph Cat. No. (`) (Nos.)
Range (Nos.) Per Unit
Per Unit
HP kW (A)
Single Moving Contact SS91009 25 10
15.0 11.0 9 - 15 MN 16 FASD SS94362 10255 1
Std. Operating coils
25.0 18.5 14 - 23 MN 25 FASD SS94364 11465 1 400 / 440V, 50Hz SS90047 150 10
35.0 26.0 20 - 33 MN 32 FASD SS94366 18865 1 360V, 50Hz SS90165 150 10
50.0 37.5 30 - 50 MN 45 FASD SS94021 30295 1 230V, 50Hz SS90045 150 10
220V, 50Hz SS90044 150 10
75.0 55.0 45 - 75 MN 65 FASD SS94022 50205 1
110V, 50Hz SS90043 150 10
90.0 67.0 45 - 75 MN 80 FASD SS94705 54885 1
Auxiliary contact block: 1 NO + 1 NC SS90120 200 50
125.0 90.0 66 - 110 MN 110 FASD SS94706 71830 1
Spare kit without coil SS90983 335 50
175.0 130.0 90 - 150 MN 140 FASD SS94707 75195 1 Thermal timer without combination coil SS90224 575 1
Combination coils
Combination coils for 400 / 440V, 50Hz SS90443 370 10
Fully-Automatic Star-Delta Starters Combination coils for 230V, 50Hz SS90444 370 10
in Sheet-Steel Enclosure Type MK, ML, MU & MB Combination coils for 380V, 50Hz SS90445 370 10
(Motor Rating AC-3 Duty, 415V, 50Hz, 3Ph) Combination coils for 360V, 50Hz SS90446 370 10
Push Button Unit SS90004 90 1
Arc Shield SS50004 95 1
Contact bridge without Contacts SS50005 90 1

MK 1F MB 1F MU 2F
Spares for MN Starters
Max. Motor Relay
M.R.P. Std.
Output at Max.
Description Cat. No. (`) Pkg. M.R.P. Std.
415V, 3-Ph Range (Nos.)
Per Unit Description Cat. No. (`) Pkg.
HP kW (A)
Per Unit (Nos.)
12.5 9.3 9 - 14 MK1 FASD SS96254 6970 1
Bracket for Mounting cont. MNX 25 - 32 SS94030OOOO 100 20
15.0 11.0 11 - 18 MK1 FASD SS96257 7015 1
15.0 11.0 13 - 22 MK1 FASD SS96259 7060 1
15.0 11.0 13 - 21 MU1 FASD # SS95890 9495 1
15.0 11.0 14 - 23 MB1 FASD # SS95894 9555 1
30.0 22.5 20 - 32 MU2 FASD # SS95892 11430 1
30.0 22.5 20 - 33 MB2 FASD # SS95896 11560 1
For lower relay ranges, please refer Agricultural Electrical Products' price list.

Salient Features and Benefits of Starters


l Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
l Sheet steel enclosures with IP 54 protection

ML 2F ML 1.5F l Wide range of relay settings and coil voltages


Max. Motor Relay l Standardized accessories and spares available
Output at M.R.P. Std.
Max.
Description Cat. No. (`) Pkg.
415V, 3-Ph Range Per Unit (Nos.)
HP kW (A)
25.0 18.5 13 - 21 ML1.5 FASD SS91855 12345 1
35.0 26.0 20 - 32 ML2 FASD SS90705 19595 1
50.0 37.5 28 - 42 ML3 FASD SS90730 32280 1
75.0 55.0 45 - 75 ML4 FASD SS90913 55315 1
125.0 90.0 66 - 110 ML6 FASD SS90923 90690 1
250.0 180.0 135 - 225 ML10 FASD * SS90938 143545 1
400.0 300.0 180 - 300 ML12 FASD * SS91019 162595 1
Note: 1) # Type MU1 / MU2 consists of type MU Relay + MU1 / MU2 contactors
Type MB1 / MB2 consists of type MN Relay + MU1 / MU2 contactors
2) For Ordering Suffix please refer table B page No. 20
* Available till stock last

L&T, ESP 01.01.2015 19


Submersible Pump Controllers
Submersible Pump Controller Submersible Pump Controller
In Sheet Enclosure Type MU - G In Sheet Enclosure Type MU-G
(Motor Rating AC-3 Duty, 415V, 50Hz, 3 phase) (Motor Rating AC-3 Duty, 415V, 50 Hz, 3 phase)

MU - G6 MU - G10 MU-G15 MU-G20 MU-G50 MU-G75


Max. Motor Relay Max. Motor Relay
M.R.P. Std. Output at Max. M.R.P. Std.
Output at Max. Description Pkg.
Description Cat. No. (`) Pkg. Cat. No. (`)
415V, 3-Ph Range 415V, 3-Ph Range
Per Unit (Nos.) Per Unit (Nos.)
HP kW (A) HP kW (A)

6 4.5 9 - 14 MU - G6 DOL Starter* SS97756 5200 1 MU-G15 Fully Automatic


15 11 13 - 22 CS94091 10145 1
Star - Delta Starter*
10 7.5 13 - 21 MU - G10 DOL Starter* SS95983 6180 1
MU-G20 Fully Automatic
20 15 13 - 21 SS95984 11870 1
10 7.5 28 - 42 MU - G10H DOL Starter* SS95974 7235 1 Star - Delta Starter*
* For lower relay ranges, please refer Agricultural Electrical Products' price list. MU-G20H Fully Automatic
20 15 28 - 42 SS95975 14525 1
Star - Delta Starter*
MU-G30 Fully Automatic
30 22.5 30 - 50 CS96008 23995 1
Star - Delta Starter*
MU-G50 Fully Automatic
50 37.5 45 - 75 CS96009 38330 1
Star - Delta Starter*
MU-G75 Fully Automatic
75 101 66 - 110 CS96451 52430 1
Submersible Pump Controller Star - Delta Starter*
In Sheet Steel Enclosure Type MR-G, MF-G * For lower relay ranges, please refer Agricultural Electrical Products' price list.

M-POWER - Module for


MR-G2 MF-G1 Mobile Starter
Max. Motor Relay M.R.P. Std.
M.R.P. Std. Description Cat. No. (`) Pkg.
Output at Max.
Description Cat. No. (`) Pkg. Per Unit (Nos.)
230V, 3-Ph Range (Nos.)
Per Unit
HP kW (A) Module for Mobile Starter &
GSM0301OOOO 5950 1
Submersible Controllers
0.5 0.37 6 - 10 SS96988 3450 1
1.0 0.75 9 - 14 Type MR-G2 * SS96560 3765 1
1.5 1.1 11 - 18 For Single SS96989 4160 1
Phase Motors Salient Features and Benefits of
2.0 1.5 13 - 22 (Only Ammeter Version) SS96990 4355 1
3.0 2.2 13 - 22 SS97725 4660 1
Submersible Pump Controller
l Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
0.5 0.37 6.5 - 11 SS97734 2315 1
Type MF-G1 * l Protections Offered - Overload, Single Phasing,
1.0 0.75 12 - 20 SS97736 2415 1 Phase reversal, Phase imbalance
For Single
1.5 1.1 12 - 20 Phase Motors SS97737 2500 1 l Auto Restart Feature
(Only Ammeter Version)
2.0 1.5 12 - 20 SS97738 2545 1 l Vibration proof enclosure with IP54 protection class
Note: For dual meter (Ammeter + Voltmeter) version - Add (`) 210 l Indications Offered - ON/OFF, Voltage and Ampere
* For lower Relay Ranges & dual meter version, please refer Agricultural Electrical l Compatible with M-POWER
Products' price list.

Ordering Suffix for MK1/MU/MB/ML & MN Starters


Table B
Coil Voltages Relay Range (A)
B - 240 V MK1 MU MB ML MN
C - 360 V A : 9 - 14 A : 9 - 14 B : 9 - 15 A : 9 - 14 B : 9 - 15
D - 415 V C : 11 - 18 C : 13 - 21 D : 14 - 23 B : 10 - 16 D : 14 - 23
P - 440 V D : 13 - 22 D : 15 - 25 E : 20 - 33 C : 13 - 21 E : 20 - 33
M : 1 - 1.6 E : 20 - 32 E : 20 - 32 G : 30 - 50
P : 1.5 - 2.5 G : 24 - 38 F : 28 - 42 J : 45 - 75
R : 2.5 - 4 F : 28 - 42 G : 30 - 50 K : 66 - 110
T : 4 - 6.5 J : 45 - 75 Q : 2 - 3.3
V : 6 - 10 K : 66 - 110 S:3-5
M : 90 - 150 U : 4.5 - 7.5
P : 135 - 225 V : 6 - 10
Q : 180 - 310
R : 2.5 - 4
T : 13 - 21

20 L&T, ESP 01.01.2015


Timers
Electronic Timers Type ST 100 Thermal Timers Type GT 200

ST 100 GT 200
M.R.P. Std M.R.P. Std
Description Cat. No. (`) Pkg. Description Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
240 / 360 / 415V, 50Hz for Operating Voltages:
3 - 30 secs. 230 / 250V, 360V, 400 / 440V, 500V, SS91270 2480 1
ST80328OOOO 1440 1
50 Hz for 5 - 18 secs. range
12 - 120 secs. ST80329OOOO 1440 1

Note: ST 100 supplied with Mounting Kit, suitable for ET 100 replacement.
For Complete range of Timing Devices, please refer the Panel Accessories
Price List. Ordering Suffix for GT 200 Timer

Voltage (V) Suffix


Salient Features and Benefits of 250V NOOO

Electronic Timers ST 100 320V ROOO


360V COOO
l Wide operating voltage band of 160V to 500V
380V LOOO
l Available in Time-Delay range of 3-30Sec and 12-120Sec
400 / 440V POOO
l 1-mod design provides compactness in size
l Suitable for base mounting and DIN mounting
l Ease of connection
l Star-Operation LED display to indicate Star to Delta changeover

Single Phase Preventor Relay

Salient Features and Benefits of


Single Phase Preventer Relay
l Protection from
- Single Phasing condition
- Phase Reversal condition
Sz5 SDz5 - Phase Unbalance condition
l Modes of Operation
M.R.P. Std.
Description Cat. No. (`) Pkg. - Auto
Per Unit (Nos.) - Manual
SPPR type Sz5 (7 Wire), 380V ST92166OOOO 630 1 - Bypass
SPPR type Sz5 (6 Wire), 360V CS94824COOO 630 1 l Auto-Restart benefit with 30sec fixed time ON-Delay
SPPR type Sz5 (6 Wire), 380V CS94824LOOO 630 1 l Colourful dial and Colourful wiring for ease of connection with Starter
SPPR type Sz5 (6 Wire), 415V CS94824DOOO 630 1 l Compact in dimensions
SPPR type SDz5, SPPR + Timer, 360V XM81808OOOO 1250 1 l Sz5 SPPR is suitable for DOL Starter and SDz5 SPPR is suitable for
SPPR type SDz5, SPPR + Timer, 380V XM81807OOOO 1250 1 Star-Delta Starter.
SPPR type SDz5, SPPR + Timer, 415V XM81809OOOO 1250 1 l Sz5 SPPR is available in 6-wire version and 7-wire version
l SDz5 has in-built Star-Delta Timer

22 L&T, ESP 01.01.2015


Introducing
MU-2P DOL
MU-2P DOL Single Phase Starter
l Single Phase Starter for
l Monoblock Pumps

l Jet Pumps

l Compressor Pumps

l Works even at 120V (low voltage)


l Complete safety with neutral isolation
Digital Soft Starters
EMX3 Soft Starters

Ordering Information for EMX3 Soft Starter

Suitable for Motor with E M X 3


#
Rated Current in Amps M.R.P.
Bypass
EMX3 Cat. No. 3 Wire 6 Wire (`) Keypad
Contactor
(Inline (Inside Delta Per Unit 1 = with keypad
Connection) Connection) Control voltage
1 = 110-210 VAC & 220-440 VAC
EMX3-0023B-411 23 34 68200 Mains voltage
4 = 200 ~ 440 VAC
EMX3-0043B-411 43 64 73200
Bypass
EMX3-0053B-411 53 79 85400 B = Internally Bypassed
C = Non-Bypassed
EMX3-0076B-411 76 114 91400 (External contactor required)
EMX3-0097B-411 97 145 100000 Nominal current rating
0023 - 23A
EMX3-0105B-411 105 157 116000 .
.
EMX3-0145B-411 145 217 134000 1600 - 1600A
EMX3-0170B-411 170 255 152000
EMX3-0220B-411 220 330 168000
Built - In
EMX3-0255B-411 255 382 245000
EMX3-0350B-411 350 525 298000
EMX3-0425B-411 425 638 352000
EMX3-0500B-411 500 750 380000
EMX3-0580B-411 580 870 443000
EMX3-0700B-411 700 1050 499000 EMX3 Soft Starters : For Heavy Duty Applications
EMX3-0820B-411 820 1230 562000 Ratings from 23 to 1600A
Control Voltage from 94VAC to 484VAC
EMX3-0920B-411 920 1380 658000
Constant current
EMX3-1000B-411 1000 1500 719000
XLR-8 Adaptive acceleration control for pumps
Kickstart
XLR-8 Adaptive deceleration control for pumps
Forward / Reverse Jog
Comprehensive motor protection
Large LCD Keypad
Auto Start / stop
2 motor data sets
Fully programmable overload trip
Suitable for Motor with
# 5 digital inputs, 4 digital outputs,
Rated Current in Amps M.R.P.
Bypass 1 analog output
EMX3 Cat. No. 3 Wire 6 Wire (`)
Contactor Built-in RTD & Thermistor inputs
(Inline (Inside Delta Per Unit
Connection) Connection) 99 event logs with time stamping
EMX3-0255C-411 255 382 177000 Starter communication timeout
Terminals for Network communication trip
EMX3-0360C-411 360 540 188000
connecting External Auto detection of inline or inside
EMX3-0430C-411 400 645 285000
contactor (AC1 duty) delta power connection
EMX3-0620C-411 620 930 293000
Programmable auto start/stop
EMX3-0650C-411 650 975 310000 24 VDC auxiliary power supply
EMX3-0790C-411 790 1185 378000 Power through operation allows to run soft
* All protections
EMX3-0930C-411 930 1395 475000 starter even with one SCR shorted
remain active
EMX3-1200C-411 1200 1800 732000 Emergency run operation
during bypass
EMX3-1410C-411 1410 2115 878000
I/O expansion card (optional)
operation
EMX3-1600C-411 1600 2400 970000

# Note : The above EMX3 current ratings are based on 300% starting current,
10 starts per hour, 10 seconds starting time and ambient temperature of 45C. We recommend the use of :
For proper sizing of soft starter based on the application parameters please use 1. Line Contactor : This will isolate and protect the soft starter SCR's
Winstart Software. from any voltage transient while it's not in operation.
For Winstart software please contact Customer Interaction Centre.
2. Bypass Contactor (For models without built-in bypass) : This will
bypass and protect the soft starter SCR's while in running state from
Current and Voltage transient's.
3. Semiconductor fuses : This will protect the starter SCR's during
starting and stopping states from current transient's and excess IT.

24 L&T, ESP 01.01.2015


Digital Soft Starters
CSX Soft Starters CSXi Soft Starters

Ordering Information for CSX Series Soft Starter

M.R.P. M.R.P. C S X
Motor Motor
Cat. No. (`) Cat. No. (`)
kW kW
Per Unit Per Unit Control Voltage
1 = 110 VAC & 220-440 VAC
7.5 CSX-007-41 28600 7.5 CSXi-007-41 41500 Mains voltage
4 = 200 ~ 440 VAC
15 CSX-015-41 30300 15 CSXi-015-41 48100
Normal kW rating @ 400VAC
007 7.5 kW
18 CSX-018-41 31400 18 CSXi-018-41 50500 .
.
22 CSX-022-41 37100 22 CSXi-022-41 53900 110 110 kW

30 30 Motor protection
CSX-030-41 41800 CSXi-030-41 60000
Blank (no space) - Without
motor protection
37 CSX-037-41 47900 37 CSXi-037-41 65700 i - With motor protection

45 CSX-045-41 54500 45 CSXi-045-41 79200

55 CSX-055-41 59400 55 CSXi-055-41 86700

75 CSX-075-41 80900 75 CSXi-075-41 101000

90 CSX-090-41 88000 90 CSXi-090-41 127000

110 CSX-110-41 97000 110 CSXi-110-41 141000

Note : The above CSX & CSXi ratings are based on 400% starting current,
10 starts per hour up to 30kW & 6 starts per hour for 37kW & above, 6 seconds
starting time and ambient temperature of 45C.
For proper sizing of soft starter based on the application parameters please use
Winstart Software.
CSX Soft Starters : For Standard Applications
Inbuilt Bypass Contactor
Optional Modules/Cards for CSX / CSXi / EMX3 Soft Start / Soft Stop
Compact
Complements existing motor protection
Truly plug & play
Communication options available

CSXi Soft Starters : For standard applications


M.R.P. Inbuilt Bypass Contactor
Description Cat. No. (`) Soft start / Soft stop / Adjustable current limit
Per Unit
Essential motor protections against
Modbus Interface PIM-MB-01 13000
Overload
Profibus Interface PIM-PB-01 21000 Single phasing
DeviceNet Interface PIM-DN-01 17000 Instantaneous overcurrent
Phase sequence reversal
USB Interface PIM-USB-01 8000
Abnormality in supply
Modbus TCP Module PIM-MT-01 40000 Unbalanced current
Ethernet IP Module PIM-EI-01 44000 Thermistor protection through PTC
PIM-PN-01
Excess start time setting
Profinet Module 44000
Communication options available
EMX3 RTD/Ground Fault Expansion Card 995-04804-00 17000
PC Interface as optional
EMX3 I/O Expansion Card 995-04803-00 10000

We recommend the use of :


1. Line Contactor : This will isolate and protect the soft starter SCR's
from any voltage transient while it's not in operation.
2. Bypass Contactor (For models without built-in bypass) : This will
bypass and protect the soft starter SCR's while in running state from
Current and Voltage transient's.
3. Semiconductor fuses : This will protect the starter SCR's during
starting and stopping states from current transient's and excess IT.

L&T, ESP 01.01.2015 25


Switch-Disconnector-Fuse Units
Type FN S-D-F suitable for Type FN S-D-F suitable for
DIN fuse-link (2P / 3P) BS fuse-link (TPN)
Also for 220Vdc Also for Capacitor,
Features offered by FN S-D-F & 240Vac Motor back-up &
application 440Vdc
l Range 32A to 800A, 415V, AC 23A application
l 2P / TP / TPN Versions

l Suitable for cylindrical / DIN / Bolted fuse-link

l Conforms to IEC 60947-3, IS/IEC 60947-3

l Door interlock & padlock facility

FN 2P S-D-F FN TP S-D-F FN - TPN S-D-F

Type FN (2P) S-D-F suitable Type FN (TP) S-D-F suitable Type FN (TPN) S-D-F suitable
for DIN fuse-link for DIN fuse-link for bolted fuse-link
Rated Suitable Open Execution Open Execution Suitable Open Execution Std.
Size Current fuse-link fuse-link Pkg
(A) type M.R.P. M.R.P. type M.R.P. (Nos.)
Type Cat. No. (`) Type Cat. No. (`) Type Cat. No. (`)
Per Unit Per Unit Per Unit
32 HF 14x51 FN 32 2P SK95594 1370 FN 32 TP ST27892 1560 A1L FN 32 TPN SK95653 1640 1
Fr 1
63 HF 14x51 FN 63 2P SK95595 1880 FN 63 TP ST27893 2190 A1L FN 63 TPN SK95651 2300 1
100 HN Size 000/00 FN 100 2P ST35086 3830 FN 100 TP ST30287 4380 A4 FN 100 TPN SK95570 4600 1
Fr 2 125 HN Size 000/00 FN 125 2P ST35087 4880 FN 125 TP ST27894 5740 A4 FN 125 TPN SK95009 5660 1
160 HN Size 000/00 FN 160 2P ST35088 5220 FN 160 TP SK95998 6260 A4 FN 160 TPN SK95714 6150 1
200 HN Size 0 FN 200 2P ST35089 6540 FN 200 TP ST27895 8070 B2 FN 200 TPN SK95588 7850 1
Fr 3
250 HN Size 1 FN 250 2P ST31674 7860 FN 250 TP ST31731 10060 B2 / B3 FN 250 TPN SK95682 9660 1
315 HN Size 1 FN 315 2P ST38930 9990 FN 315 TP ST27897 12680 B3 FN 315 TPN SK95590 12660 1
Fr 4
400 HN Size 2 FN 400 2P ST31676 11920 FN 400 TP ST27898 14990 B4 FN 400 TPN SK95591 13990 1
630 HN Size 3 FN 630 2P ST35090 19240 FN 630 TP ST27899 24610 C2 FN 630 TPN SK95592 23650 1
Fr 5
800 HN Size 3 - - - FN 800 TP ST27900 26450 - - - - 1

Type FN S-D-F suitable for DIN fuse-link (TPN)


Features offered by FN S-D-F
l Range 32A to 800A, 415V, AC 23A

l Suitable for cylindrical / DIN fuse-link

l Available in interior / Sheet steel enclosure version

l Conforms to IEC 60947-3, IS/IEC 60947-3

l Door interlock & padlock facility


FN - TPN S-D-F (Open Execution) FN - TPN S-D-F in SS Enclosure

Open Execution Type FN (TPN) S-D-F In Sheet Steel Enclosure Type FN (TPN) S-D-F
Suitable HRC fuse-link
Rated suitable for DIN fuse-link Std. suitable for DIN fuse-link Std.
Size Current M.R.P. Pkg. M.R.P. Pkg.
Range
(A) Type Type Cat. No. (`) (Nos.) Type Cat. No. (`) (Nos.)
(A)
Per Unit Per Unit
32 HF 2 to 32 FN 32 TPN / FP SK95518 1640 1
FN 32 TPN / FP CE* SK95612* 3750 1
32 HF 2 to 32 FN 32 TPN / FP CE* SK95703* 1470 1
Fr 1
63 HF 2 to 63 FN 63 TPN / FP SK95421 2290 1
FN 63 TPN / FP CE* SK95613* 4470 1
63 HF 2 to 63 FN 63 TPN / FP CE* SK95704* 2030 1
100 HN Size 000/00 63 to 100 FN 100 TPN SK95568 4770 1 FN 100 TPN SK95569 7360 1
Fr 2 125 HN Size 000/00 63 to 125 FN 125 TPN SK95001 6270 1 FN 125 TPN SK95005 8720 1
160 HN Size 000/00 63 to 160 FN 160 TPN SK95713 6830 1 FN 160 TPN SK95715 9340 1
200 HN Size 0 80 to 200 FN 200 TPN SK95418 8730 1 FN 200 TPN SK95511 12280 1
Fr 3
250 HN Size 1 125 to 250 FN 250 TPN SK95642 10360 1 FN 250 TPN SK95681# 14170 1
315 HN Size 1 125 to 315 FN 315 TPN SK95461 12800 1 FN 315 TPN SK95514 16800 1
Fr 4
400 HN Size 2 200 to 400 FN 400 TPN SK95481 15430 1 FN 400 TPN SK95515 19600 1
630 HN Size 3 315 to 630 FN 630 TPN SK95521 24820 1 FN 630 TPN SK95547 31420 1
Fr 5
800 HN Size 3 315 to 800 FN 800 TPN SK95679 26800 1 FN 800 TPN SK95705 33710 1

* CE handle has door interlock facility without defeat feature


# Spare cat no. ST97895OOOO is of Interior FN 250 SDF suitable for Sheet steel enclosure
Notes: 1) Please refer page no. 29 for Switch-Disconnector & 4 pole Switch-Disconnector-Fuse
2) Type FN S-D-F range (Bolted fuse-link) suitable for harsh environment is also available. Please contact nearest branch office for further details
3) For 690 Vac application please contact nearest branch office.
4) More spacious SS Enclosures (does not require separate cable gland box). Version available on request

26 L&T, ESP 01.01.2015


HRC Fuses
Features offered by HRC fuse link
l Conforms to IEC 60269-2, IS 13703 part 2

l Range: 2A to 800A, 415V, AC 50Hz

l Type: Cylindrical (2A to 63A), DIN (63A to 800A) & Bolted (2A to 630A)

l High breaking capacity: 100kA for type HN and 80kA for type HF/HG/HQ

Cylindrical fuse links Type HF


Rated M.R.P. Std.
Size Current Description Cat. No. (`) Pkg.
(A) Per Unit (Nos.)
2 SF90144 92 30
4 SF90145 92 30
HF 2A 6 SF90146 92 30
Suitable for Type FN 32 / 63 /
8 SF90147 92 30
FNX 32 / 63 S-D-F
10 SF90148 92 30
& for HCO 32 Fuse base
16 SF90150 92 30
14 X 51
20 SF90151 92 30
25 SF90152 92 30
HF 63A 32 SF90142 92 30
40 SF90143 105 30
Suitable for Type FN 63 / FNX 63 S-D-F
50 SF90158 230 30
& for HC 63 Fuse base
63 SF90159 297 30

DIN Type Fuse Links Type HN


Rated M.R.P. Std.
Size Current Description Cat. No. (`) Pkg.
(A) Per Unit (Nos.)
63 SF94940 305 3
80 Suitable for Type SF94941 325 3
FN 100/125/160 / FNX 100/125/160 S-D-F
000 000 100 & for HB 160 Fuse base SF94942 325 3
125 SF94946 375 3
63 SF94027 385 3
80 Suitable for Type SF94028 385 3
00 00 100 FN 100/125/160 / FNX 125/160 S-D-F SF94029 385 3
& for HB 160 Fuse base SF94030 3
125 400
160 SF94939 415 3
80 SF94128 515 3
0 100 SF94129 515 3
Suitable for Type
0 125 FN 200 / FNX 200 S-D-F SF94130 515 3
160 & for HB 250 Fuse base SF94131 525 3
200 SF94132 525 3
125 SF94230 560 3
1 160 SF94231 585 3
Suitable for Type
1 200 FN 250/315 / FNX 250/315 S-D-F SF94232 585 3
250 & for HB 250 Fuse base SF94233 650 3
315 SF94234 765 3
200 SF94332 805 3
2 250 Suitable for Type SF94333 835 3
FN 400 / FNX 400 S-D-F
2 315 & for HB 800 Fuse base SF94334 860 3
400 SF94335 865 3
315 SF94434 1190 1
400 Suitable for Type SF94435 1190 1
3 3 500 FN 630/800 / FNX 630/800 S-D-F SF94436 1340 1
& for HB 800 Fuse base
630 SF94437 1365 1
800 SF94938 1660 1

Fuse holders & Fuse bases suitable for Cylindrical / DIN fuse-links
Rated Suitable fuse-link M.R.P. Std.
Current Type Description Cat. No. (`) Pkg.
Type Range (A)
(A) Per Unit (Nos.)
32 HCO 32 Fuse holder HF 2-32 SK91314 175 10
63 HC 63 Fuse holder HF 2-63 SK91043 195 10
160 HB 160 Fuse base HN-Size 000 & 00 63-160 SK90405 310 12
250 HB 250 Fuse base HN-Size 0 & 1 80-250 SK90406 610 3
800 HB 800 Fuse base HN-Size 2 & 3 200-800 SK91051 1275 3
HB HCO

L&T, ESP 01.01.2015 27


HRC Fuses
Bolted fuse links: Type HG and HQ
M.R.P. Std.
Fixing Rating
Type Size Description Cat. No. (`) Pkg.
Method (A)
Per Unit (Nos.)
F1
2 ST30725 45 24
4 ST30726 45 24
6 ST30727 45 24
10 Suitable for type ST30728 45
Offset, 24
HG F1 HD 20H/20P/20B,
A2 staggered 16 ST30729 45 24
HD 32H/32P/32B fuse base
A1 L 20 ST30730 50 24
25 ST30731 50 24
32 ST30732 50 24
20 ST34527 77 15
25 ST34528 77 15
Suitable for type
A1L 32 ST34529 83 15
FN 32/63 S-D-F
50 ST35827 83 15
A3 63 ST35828 83 15
4 ST30747 66 12
B1 6 ST30748 66 12
10 ST30749 66 12
Suitable for type
A2 16 ST30750 66 12
HK 32H/32B fuse base
Offset 20 ST30751 66 12
25 ST30752 66 12
32 ST30753 66 12
35 ST30759 95 12
Suitable for type
A3 50 ST30760 95 12
B2 HK 63B/63H Fuse base
63 ST30761 95 12
80 ST30767 180 12
HQ Suitable for type
B3 100 ST30768 185 12
A4 FN 100/125/160 S-D-F
125 & for HK 125H/125B Fuse base ST30769 224 12
160 ST35829 229 12
80 ST30774 205 12
B1 100 ST30775 205 12
125 Suitable for type ST30776 260 12
125 FN 200 S-D-F ST30777 285 3
B4 Centre Tag, B2 160 ST30778 295 3
2 holes 200 ST30779 295 3
250 Suitable for type ST30781 430 3
B3
315 FN 250/315 S-D-F ST30782 440 3
C2 355 660
Suitable for type ST30783 3
B4
400 FN 400 S-D-F ST30784 695 3
400 ST30785 1195 1
Centre Tag, Suitable for type
C2 500 ST30786 1400 1
4 holes FN 630 S-D-F
630 ST30787 1470 1

Fuse holders suitable for bolted fuse-links

Rated Suitable M.R.P. Std.


Fuse
Current Type Connection Method Fuse Cat. No. (`) Pkg.
Type
(A) Range (A) Per Unit (Nos.)
HD 20H Both side cable (Front) F1 2-20 ST30772 110 12
20 HD 20P Both side busbar (Back) F1 2-20 ST30773 120 12
HD 20B Top busbar & bottom cable F1 2-20 ST30766 115 12
HD 20B HD 20H HD 20P
HD 32H Both side cable (Front) F1 2-32 ST30733 120 12
HD 32P Both side busbar (Back) F1 2-32 ST30734 150 12
Rear View 32
HD 32B Top busbar & bottom cable F1 2-32 ST30735 140 12
HK 32H Both side cable (Front) A2 4-32 ST30754 185 12
HK 32B Top busbar & bottom cable A2 4-32 ST30755 215 12
HK 63H Both side cable (Front) A3 35-63 ST30762 245 6
63
HK 63B Top busbar & bottom cable A3 35-63 ST30763 300 6
HK 125H Both side cable (Front) A4 80-125 ST30770 765 3
125
HD 20B HD 20H HD 20P HK 125B Top busbar & bottom cable A4 80-125 ST30771 840 3

28 L&T, ESP 01.01.2015


Switch-Disconnector-Fuse Units
Type FNX S-D-F suitable for DIN fuse-link in open execution

Features offered by FNX S-D-F


l Range 32A to 800A, 415V, AC 23A
l TPN and 4P version

l Suitable for cylindrical / DIN fuse-link

l Telescopic shaft for depth adjustment

l DIN rail mounting up to 100A

l Conforms to IEC 60947-3, IS/IEC 60947-3

l Door interlock & padlock facility FNX TPN S-D-F FNX 4P S-D-F

Open Execution Type FNX (TPN) S-D-F Open Execution Type FNX (4P) S-D-F
Rated suitable for DIN fuse-link suitable for DIN fuse-link Std.
Suitable Range
Size Current M.R.P. Std. M.R.P. Pkg.
fuse-link type (A)
(A) Type Cat. No. (`) Pkg. Type Cat. No. (`) (Nos.)
Per Unit (Nos.) Per Unit
32 HF 2 to 32 FNX 32 TPN / FP SK96903 1820 1 FNX 32 TPN / FP SK96903 1820 1
Fr 1
63 HF 2 to 63 FNX 63 TPN / FP SK96904 2410 1 FNX 63 TPN / FP SK96904 2410 1
Fr 2 100 HN Size 000 63 to 100 FNX 100 TPN / FP SK96906 4770 1 FNX 100 TPN / FP SK96906 4770 1
125 HN Size 000/00 63 to 125 FNX 125 TPN SK95806 6450 1 FNX 125 FP SK95814 6550 1
Fr 3
160 HN Size 000/00 63 to 160 FNX 160 TPN SK95807 7290 1 FNX 160 FP SK95815 7360 1
200 HN Size 0 80 to 200 FNX 200 TPN SK95808 9310 1 FNX 200 FP SK95816 9500 1
Fr 4
250 HN Size 1 125 to 250 FNX 250 TPN SK95809 11070 1 FNX 250 FP SK95817 11130 1
315 HN Size 1 125 to 315 FNX 315 TPN SK95810 13480 1 FNX 315 FP SK95818 13730 1
Fr 5
400 HN Size 2 200 to 400 FNX 400 TPN SK95811 16490 1 FNX 400 FP SK95819 16540 1
630 HN Size 3 315 to 630 FNX 630 TPN SK95812 26530 1 FNX 630 FP SK95820 26660 1
Fr 6
800 HN Size 3 315 to 800 FNX 800 TPN SK95813 28620 1 FNX 800 FP SK95821 28860 1

Note : For 690 Vac application please contact nearest branch office.

Type FN & Switch-Disconnector (2P / TPN / 4P)


Features offered by S-D
l Range 32A to 2000A, 415V, AC 23A
l Conforms to IEC 60947-3, IS/IEC 60947-3

l Door interlock & padlock facility

l Telescopic shaft for depth adjustment 1000A and above

l Flip-able handle 1000A and above

FN 2P S-D FN TPN S-D

New
Open Execution 2P S-D Open Execution TPN S-D
Rated Std. Std.
Size Current M.R.P. Pkg. M.R.P. Pkg.
(A) Type Cat. No. (`) (Nos.) Type Cat. No. (`) (Nos.)
Per Unit Per Unit
32 FN 32 2P SK90418OOOO 1250 1 FN 32 TPN / 4P SK95541OOOO 1710 1
Fr 1
63 FN 63 2P SK90419OOOO 1710 1 FN 63 TPN / 4P SK95540OOOO 2370 1
100 FN 100 2P SK90420OOOO 3480 1 FN 100 TPN SK95571OOOO 4480 1
Fr 2
125 FN 125 2P SK90421OOOO 4440 1 FN 125 TPN SK95405OOOO 5580 1
200 FN 200 2P SK90450OOOO 5950 1 FN 200 TPN SK95607OOOO 7610 1
Fr 3
250 FN 250 2P SK90454OOOO 7150 1 FN 250 TPN SK95683OOOO 9690 1
315 FN 315 2P SK90465OOOO 9090 1 FN 315 TPN SK95609OOOO 11200 1
Fr 4
400 FN 400 2P SK90466OOOO 10850 1 FN 400 TPN SK95610OOOO 13960 1
630 FN 630 2P SK90467OOOO 17500 1 FN 630 TPN SK95611OOOO 20860 1
Fr 5 800 FN 800 2P SK90468OOOO 18350 1 FN 800 TPN SK95551OOOO 24040 1
1000 FN 1000 2P SK90469OOOO 23580 1 FN 1000 TPN SK95710OOOO 31510 1
1000 - - - - COS SD 1000 4P COS1000OO4O 35000 1
1250 - - - - COS SD 1250 4P COS1250OO4O 40820 1
New Fr 6
1600 - - - - COS SD 1600 4P COS1600OO4O 54600 1
2000 - - - - COS SD 2000 4P COS2000OO4O 67800 1

L&T, ESP 01.01.2015 29


Switch-Disconnector-Fuse: Spares & Accessories
Spares & Accessories for type FNX Spares & Accessories for type FN

Castell Lock DIN Rail Assembly Terminal Shroud Kit Handle Assembly

Auxiliary Contact Kit Handle Assembly Switched Neutral Kit Auxiliary Contact Kit

M.R.P. Std.
Description Type Cat. No. (`) Pkg.
Per Unit (Nos.)
FNX 32 / 63 SK91537 160 1
FNX 100 SK91538 310 1
Auxiliary Contact Kit
FNX 125 / 160 SK91539 310 1
(1NO + 1 NC)
FNX 200 / 250 SK91540 400 1 Shaft Extension Kit Castell lock
FNX 315 / 400 / 630 / 800 SK91541 445 1
FNX 32 / 63 / 100 SK91524 270 1 M.R.P. Std.
Description Type Cat. No. (`) Pkg.
Handle Assembly FNX 125 / 160 / 200 / 250 SK91525 510 1 Per Unit (Nos.)
FNX 315 / 400 / 630 / 800 SK91526 640 1 FN 32 / 63 SK91302 370 1
FNX 32 / 63 / 100 SK91530 500 1 FN 100 / 125 / 160 SK91328 420 1
Auxiliary Contact Kit
Castell Lock FNX 125 / 160 / 200 / 250 SK91531 880 1 FN 200 / 250 SK91329 495 1
(1NO + 1 NC)
FNX 315 / 400 / 630 / 800 SK91531 880 1 FN 315 / 400 / 630 / 800 SK91330* 545 1
DIN Rail Assembly FNX 32 / 63 / 100 SK91617 65 1 FN 32 / 63 SK91190 90 1
FN 100 / 125 / 160 SK91137 120 1
Terminal Shroud Kit FN 200 / 250 SK91335 205 1
FN 315 / 400 SK91346 215 1
FN 630 / 800 SK91347* 225 1
Fuse pulling handle
FN 32 / 63 SK91257 260 1
FN 100 / 125 / 160 SK91258 570 1
Handle Assembly - A FN 200 / 250 SK91258 570 1
FN 315 / 400 / 630 / 800 SK91259* 635 1
FN 32 / 63 SK91277 260 1
For Type HN fuse-link For Type HF fuse-link FN 100 / 125 / 160 SK91278 570 1
Handle Assembly - B
M.R.P. Std. FN 200 / 250 SK91278 570 1
Description Cat. No. (`) Pkg. FN 315 / 400 / 630 / 800 SK91279* 635 1
Per Unit (Nos.)
Handle Assembly - CE FN 32 / 63 SK91337 145 1
Fuse pulling handle for FN 100 / 125 / 160 SK95233 2490 1
SK91185 110 1
HF Fuse-link from 2A-63A
FN 200 / 250 SK95516 2550 1
Insulated fuse pulling handle for Switched Neutral Kit
SF90126 410 1 FN 315 / 400 SK95517 2660 1
Type HN fuse-link from 63A-800A
FN 630 / 800 SK95546* 3600 1
FN 200 SK91343 190 1
Interphase Barrier Kit FN 315 / 400 SK91344 200 1
FN 630 / 800 SK91345* 210 1
FN 100 / 125 / 160 SK95600 150 1
Spares & Accessories for type Shaft Extension Kit
FN 315 / 400 / 630 / 800 SK91331* 180 1
Switch-Disconnector A SK00333 1500 1
FN 100 / 125 / B SK00334 1500 1
M.R.P. Std.
Type Cat. No. (`) Pkg. 160 / 200 / 250 C SK00335 1500 1
Per Unit (Nos.) D 1500 1
SK00336
Castell type lock
Auxiliary Contact Kit A SK00345* 1500 1
(1 sets of C/O contact) CXS6002 550 1
FN 315 / 400 / B SK00346* 1500 1
Operating Handle CXS6001 1250 1 630 / 800 C SK00347* 1500 1
Castell type lock CX60004 1500 1 D SK00348* 1500 1

*Also suitable for Switch-Disconnector FN 1000

30 L&T, ESP 01.01.2015


On Load Changeover Switch - Disconnectors
Type changeover switch-disconnector (Conforms to IEC 60947-3 , IS/IEC 60947-3)
Features offered by Manual Changeover Features offered by Motorised Changeover
Range 63A to 2000A, 415V, AC 23A, 4P Range 125 A to 2000A, 415V, AC 23A, 4P
Site convertible fuse version for open execution (Control Voltage 240 Vac )
Site convertible dual shaft position No change in HxWxD dimension of motorised and
SS enclosure version does not require separate manual changeover switch
cable gland box Padlocking in OFF position
Staggered terminals /O
Open SS Motorised Option for selection between manual and auto mode
uilt 2 C
Inb execution
tact enclosure Changeover
ry Con
Auxilia the range
across Manual Changeover Manual Changeover New Motorised Changeover
Open Execution In Sheet Steel Enclosure# Open Execution
Rated Std.
Size Current Type M.R.P. M.R.P. M.R.P. Pkg.
(A) Cat. No. (`) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit Per Unit
63 CO1-63 CO10630OOOO 4300
CO10630OSOO 6150 1
63 CO1-63 CO10630OOOD 4030
Fr 1
100 CO1-100 CO11000OOOO 5690
CO11000OSOO 7700 1
100 CO1-100 CO11000OOOD 5270
125 CO2-125 CO21250OOOO 8570 CO21250OSOO 11440 CK90161BOOO 29050 1
Fr 2 160 CO2-160 CO21600OOOO 9370 CO21600OSOO 12510 CK90162BOOO 30000 1
200 CO2-200 CO22000OOOO 11300 CO22000OSOO 14410 CK90163BOOO 30950 1
250 CO3-250 CO32500OOOO 16290 CO32500OSOO 20110 CK90164BOOO 38500 1
Fr 3
315 CO3-315 CO33150OOOO 17240 CO33150OSOO 21070 CK90165BOOO 39000 1
400 CO4-400 CO44000OOOO 25190 CO44000OSOO 30750 CK90166BOOO 49350 1
Fr 4
630 CO4-630 CO46300OOOO 29670 CO46300OSOO 35660 CK90167BOOO 53100 1
630 CO5-630 CO56300OOOO 31050 - - CK90168BOOO 55650 1
Fr 5 800 CO5-800 CO58000OOOO 44430 CO58000OSOO 53030 CK90169BOOO 79950 1
1000 CO5-1000 CO51000OOOO 72390 CO51000OSOO 92270 CK90170BOOO 103400 1
1250 CO6-1250 CO61250OOOO -
85000 - - * * 1
New Fr 6 1600 CO5-1600 CO61600OOOO -
99500 - - * * 1
2000 CO6-2000 * * - - * * 1
Direct handle version # All sheet steel enclosure version are with extended handle switch * Available on request

Spares & Accessories for type


Motorised Changeover S-D
Spares & Accessories for type
Changeover S-D

Illuminated Push AST Controller with AuxC-1000L controller


Button assembly wire harness with wire harness
M.R.P. Std.
Description Type Cat. No. (`) Pkg.
Auxiliary Operating Handle Flip-able Handle Castell Per Unit (Nos.)
Contact (63A to 200A) (250A to 2000A) lock Illuminated Push Button
CK90195OOOO 2100 1
Control assembly with Wire harness
M.R.P. Std.
Description Type Cat. No. (`) Pkg. Accessories AST Controller with wire harness CK90192OOOO 13000 1
Per Unit (Nos.) AuxC-1000L controller AuxC-1000L ST80024OOOO 43770 1
C/O Frame 1 (63-100A) CX10002OOOO 230 1 with wire harness wire harness CK90099OOOO 2450 1
Auxiliary C/O Frame 2 (125-200A) CX20002OOOO 450 1 C/O Frame 2 & 3 (125-315A) CK90374OOOO 800 1
Contact Kit Operating
C/O Frame 3 (250-315A) CX30002OOOO 660 1 C/O Frame 4 & 5 (400-1000A) CK90378OOOO 1050 1
(2 sets of Handle
C/O contact) C/O Frame 4 (400-630A) CX40002OOOO 700 1 C/O Frame 6 (1250-2000A) CK90645OOOO 1250 1

C/O Frame 5 (800-1000A) CX50002OOOO 800 1


C/O Frame 6 (1250-1600A) CX60002OOOO 850 1
C/O Frame 1 (63-100A) CX10001OOOO 450 1 Fuse Mountable Kit
Operating C/O Frame 2 (125-200A) CX30001OOOO 800 1
Handle Kit C/O Frame 3 (250-315A) CK90392OOOO 1050 1
(handle + shaft M.R.P. Std.
+ center bush C/O Frame 4 (400-630A) CX40001OOOO 1050 1 Description Type Cat. No. (`) Pkg.
+ bush cip) Per Unit (Nos.)
C/O Frame 5 (800-1000A) CX50001OOOO 1150 1
CO 63A (suitable fuse size 14x51) CX10630OOCO 1160 1
C/O Frame 6 (1250-1600A) CX60001OOOO 1250 1
CO 125A (suitable fuse size 000) CX21250OODO 2820 1
C/O (125-1000A) CX40004OOOO 1500 1
Castell lock CO 160A (suitable fuse size 00) CX21600OODO 3740 1
C/O (1250-2000A) CX60004OOOO 1500 1
CO 200A (suitable fuse size 0) CX22000OODO 4770 1
Output C/O Frame 1 (63-100A) Top Side CX10005OOOT 500 1
shorting link Fuse CO 250A (suitable fuse size 1) CX32500OODO 5120
C/O Frame 1 (63-100A) Bottom Side CX10005OOOB 1
500 1 Mountable Kit
CO 315A (suitable fuse size 1) CX33150OODO 5360 1
CO 400A (suitable fuse size 2) CX44000OODO 7820 1
CO 630A (suitable fuse size 3) CX56300OODO 16890 1
CO 800A (suitable fuse size 3) CX58000OODO 18870 1

32 L&T, ESP 01.01.2015


Range of MCCBs
Range: 20A to 1250A
Breaking capacity: 25/36/50/70kA
Variants: 3P/4P
Our new advanced MTX3.0 release fosters Energy
Management along with most advanced protections.
It also enables communication of various parameters for
this automation era.
range can now make Total Selectivity possible
for uninterrupted healthy power network.
Why wait? Contact us today.

Range of MCCBs
DU MCCB Range
Rating (A)
16 20 25 32 40 50 63 80 100 125 160 200 250 320 400
Icu (kA)
10 DU100 / DU100B DU125U

18 DU100D

25 DU250C

30 DU100H

36 DU250

50 DU400N

2 Pole MCCBs 3 Pole MCCBs


DU100/DU125U MCCBs DU100/DU125U MCCBs

l Conforms to IS/IEC 60947-2 & IEC 60947-2 l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Range: 16A to 125A, 2P l Range: 16A to 125A, 3P
l Compact size l Compact size
l SS Enclosure available l SS Enclosure available

2 Pole Current Breaking 3 Pole


Current Std. Std.
Breaking Capacity M.R.P. Rating Capacity M.R.P.
Type Rating Pkg. Type Pkg.
Icu (kA) Cat. No. (`) (A) Icu at 415V AC Cat. No. (`)
(A) (Nos.) (Nos.)
Per Unit 50Hz. (kA) Per Unit
16 CM97795OOOO 1140 1 16 CM97751OOOO 1600 1
20 CM97796OOOO 1140 1 20 CM97752OOOO 1600 1
25 CM97797OOOO 1140 1 25 CM97753OOOO 1600 1
32 AC : 25kA @ CM97798OOOO 1140 1 32 CM97754OOOO 1600 5
240V AC, 50Hz DU100
DU100 40 CM97799OOOO 1140 1 40 CM97755OOOO 1600 1
DC : 10kA @ 10
50 CM97800OOOO 1140 1 50 CM97756OOOO 1600 1
125V DC,
63 (2P in Series) CM97801OOOO 1140 1 63 CM97757OOOO 1600 5
80 L/R < 15 msec. CM97802OOOO 1250 1 80 CM98921OOOO 1750 1
100 CM97803OOOO 1250 1 100 CM98922OOOO 1750 5
New DU125U 125 CM90965OOLY 1730 1 New DU125U 125 CM90322OOLY 2400 1

p- Spreader Terminals are included


Note: 2P in 3P frame size
DIN rail kit available as an accessory. Please refer DU100/DU125U/DU100B accessories table on page no. 36

3 Pole MCCBs
DU100B MCCBs
l Conforms to IS/IEC 60947-2 & IEC 60947-2
New For motor back-up
l Range: 16A to 100A, 3P
l Ics=100% of Icu protection MCCB
please refer page no.45
l Compact size
l SS Enclosure available

Current Breaking 3 Pole Std.


Rating Capacity M.R.P.
Type Pkg.
(A) Icu at 415V AC Cat. No. (`) (Nos.)
50Hz. (kA) Per Unit
16 CM90545OOBY 1900 1
20 CM90545OOCY 1900 1
25 CM90545OODY 1900 1
32 CM90545OOEY 1900 1
DU100B 40 10 CM90545OOFY 1900 1
50 CM90545OOGY 1900 1
63 CM90545OOHY 1900 1
80 CM90545OOJY 2050 1
100 CM90545OOKY 2050 1
p- Spreader Terminals are included
Note: DIN rail kit available as an accessory. Please refer DU100/DU125U/DU100B accessories table on page no. 36

34 L&T, ESP 01.01.2015


DU MCCB Range
3 Pole / 4 Pole MCCBs
DU100D MCCBs
New l Conforms to IS/IEC 60947-2 & IEC 60947-2 l SS Enclosure available
For motor back-up
l Range: 20A to 100A, 3P & 4P l Wide Range of snap fit Internal and
protection MCCB
l Ics=100% of Icu External Accessories please refer page no.45
l Compact size l Adjustable Overload Setting: 0.8 - 1.0 x In

Thermal Breaking Capacity 3 Pole 4 Pole Std.


Type Release Icu at 415V AC M.R.P. M.R.P. Pkg.
Range (A) 50Hz. (kA) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit
16-20 CM90517OOCO 3640 CM90518OOCO 4650 1
20-25 CM90517OODO 3640 CM90518OODO 4650 1
25-32 CM90517OOEO 3640 CM90518OOEO 4650 1
32-40 CM90517OOFO 3640 CM90518OOFO 4650 1
DU100D 18
40-50 CM90517OOGO 3640 CM90518OOGO 4650 1
50-63 CM90517OOHO 3640 CM90518OOHO 4650 1 Note: DIN rail kit available as an
63-80 CM90517OOJO 3640 CM90518OOJO 4650 1 accessory. Please refer
DU100D/DU100H accessories
80-100 CM90517OOKO 3640 CM90518OOKO 4650 1 table on page no. 36

2 Pole / 3 Pole / 4 Pole MCCBs


DU100H MCCBs
l Conforms to IS/IEC 60947-2 & IEC 60947-2 l SS Enclosure available
l Range: 20A to 100A, 2P, 3P & 4P l Wide Range of snap fit Internal and External Accessories
l Compact size l Adjustable Overload Setting: 0.8 - 1.0 x In

Thermal 2 Pole Breaking Capacity 3 Pole 4 Pole Std.


Breaking Capacity M.R.P. M.R.P. M.R.P.
Type Release Icu at 415V AC Pkg.
Icu (kA) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Range (A) 50Hz. (kA) (Nos.)
Per Unit Per Unit Per Unit
16-20 CM97898OOC2 2860 CM97894OOC2 4270 CM97933OOC2 5770 1
20-25 CM97898OOD2 2860 CM97894OOD2 4270 CM97933OOD2 5770 1
AC : 65kA @
25-32 240V AC, 50Hz CM97898OOE2 2860 CM97894OOE2 4270 CM97933OOE2 5770 1
32-40 CM97898OOF2 2860 CM97894OOF2 4270 CM97933OOF2 5770 1
DU100H DC : 15kA @ 30
40-50 CM97898OOG2 2860 CM97894OOG2 4270 CM97933OOG2 5770 1
250V DC,
50-63 (2P in Series) CM97898OOH2 2860 CM97894OOH2 4270 CM97933OOH2 5770 1
63-80 L/R < 15 msec. CM97898OOJ2 2860 CM97894OOJ2 4270 CM97933OOJ2 5770 1
80-100 CM97898OOK2 2860 CM97894OOK2 4270 CM97933OOK2 5770 1
Note: 2P in 3P frame size
DIN rail kit available as an accessory. Please refer DU100D/DU100H accessories table on page no. 36

3 Pole / 4 Pole MCCBs


DU250C/DU250/DU400N MCCBs
New
l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Range: 125A to 400A, 3P & 4P
l Compact size
l Wide Range of snap fit Internal and External Accessories
l Adjustable Overload Setting: 0.8 - 1.0 x In

Thermal Breaking Capacity 3 Pole 4 Pole Std.


Type Release Icu at 415V AC M.R.P. M.R.P. Pkg.
Range (A) 50Hz. (kA) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit
100-125 CM90631OOLO 4390 CM90634OOLO 5910 1
125-160 CM90631OOMO 5780 CM90634OOMO 7240 1
New DU250C 25
160-200 CM90631OONO 6670 CM90634OONO 8400 1
200-250 CM90631OOPO 7470 CM90634OOPO 9780 1
100-125 CM98063OOOO 6040 CM98065OOLO 7960 1
125-160 CM98062OOOO 8030 CM98065OOMO 9770 1
DU250 36
160-200 CM98061OOOO 10500 CM98065OONO 13620 1
200-250 CM98060OOOO 12130 CM98065OOPO 15760 1
250-320 CM98402OOQO 14200 CM98404OOQO 17830 1
New DU400N 50
320-400 CM98402OORO 14500 CM98404OORO 18130 1

L&T, ESP 01.01.2015 35


Accessories for DU MCCBs
Accessories for DU100/DU125U/DU100B

Auxiliary Contact Shunt Release Spreader Terminals Direct Rotary Handle


Internal External

Description M.R.P. Std. Description M.R.P. Std.


Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Auxiliary Contact Spreader Terminals
1 C/O - Right CM97781OOOO 425 1 2 Pole CM97785OOO2 145 Set of 4
1 C/O - Left CM97782OOOO 425 1 3 Pole CM97785OOOO 220 Set of 6
Trip Alarm Contact Rotary Handle
1 C/O - Right SL97037OOOO 580 1 Direct SL97044OOOO 750 1
Shunt Release DIN rail kit
240/415V AC, 110 DC - Left CM97783OOOO 550 1 DU100/DU125U/DU100B CM90944OOOO 50 1
Note: All internal accessories & ROMs are common for 2P MCCBs Note: Phase Barriers are supplied along with MCCBs

Accessories for DU100D/DU100H/DU250C/DU250

Auxiliary Contact ATAC Shunt Release UV Release Spreader Terminals Direct Rotary Handle Extended Rotary Handle
Internal External
Description M.R.P. Std. Description M.R.P. Std.
Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Auxiliary Contact Spreader Terminals
1 C/O - Right CM97886OOOO 695 1 DU100H - 2 Pole CM97785OOO2 145 Set of 4
2 C/O - Right CM97887OOOO 1240 1 DU100D/DU100H - 3 Pole CM97785OOOO 220 Set of 6
Trip Alarm Contact DU100D/DU100H - 4 Pole CM97921OOOO 320 Set of 8
1 C/O - Right CM97888OOOO 695 1 DU250C/DU250 - 3 Pole ST98053OOOO 1160 Set of 6
2 C/O - Right CM97889OOOO 1240 1 DU250C/DU250 - 4 Pole CM92007OOOO 1410 Set of 8
Auxiliary + Trip Alarm Contact Rotary Handle
1 C/O + 1C/O - Right CM97890OOOO 1240 1 DU100D/DU100H - Direct CM97895OOOO 950 1
Shunt Release DU250C/DU250 - Direct CM98040OOOO 1015 1
240/415V AC - Left CM97883OMOO 1040 1 DU100D/DU100H - Extended CM97896OOOO 1410 1
Under Voltage Release DU250C/DU250 - Extended CM98041OOOO 1450 1
240V AC - Left CM97892BOOO 1395 1 DIN rail kit
Note: All internal accessories & ROMs are common for 2P MCCBs DU100D/DU100H CM90944OOOO 50 1
Note: Phase Barriers are supplied along with MCCBs
Accessories for DU400N

Auxiliary Contact TAC Shunt Release UV Release Spreader Terminals Direct Rotary Handle Extended Rotary Handle
Internal External
Description M.R.P. Std. M.R.P. Std.
Description
Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Auxiliary Contact Spreader Terminals
1 C/O CM99801OOOO 790 1 3 Pole ST98065OOOO 2000 Set of 6
2 C/O CM99802OOOO 1350 1 4 Pole ST98066OOOO 2875 Set of 8
Trip Alarm Contact Rotary Handle
1 C/O - Right CM99803OOOO 790 1 Direct CM99860OOOO 1560 1
Auxiliary + Trip Alarm Contact Extended CM99861OOOO 2495 1
1 C/O + 1C/O - Right CM99804OOOO 1515 1
Note: Phase Barriers are supplied along with MCCBs
Shunt Release @ - NO of control contactor to be connected in series for DC control supply
110/240/415V AC, 110/220V DC CM99805OOOO 1860@ 1
24V DC CM98976O4OO 1860@ 1
Under Voltage Release
240V AC - Left CM99986BOOO 2210 1

36 L&T, ESP 01.01.2015


DH MCCB Range
Rating (A)
16 20 25 32 40 50 63 80 100 125
Icu (kA)
25 DH100
35 DH125
50 DL100

l Conforms to IS/IEC 60947-2 & IEC 60947-2


l Range: 16A to 125A, 3P & 4P
l Ics = 100% Icu
l Adjustable thermal setting: 0.8-1.0 x In
For motor back-up
l SS Enclosure available
protection MCCB
l Wide Range of Internal and External Accessories please refer page no.45
3 Pole 4 Pole
Thermal Breaking
Std.
Release Capacity Icu M.R.P. M.R.P.
Type Pkg.
Range at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.)
(A) 50Hz. (kA) Per Unit Per Unit

12-16 SL97201OOOO 5050 SL98597OOOO 6850 1


16-20 SL97202OOOO 5050 SL98598OOOO 6850 1
20-25 SL97203OOOO 5050 SL98599OOOO 6850 1
25-32 SL97204OOOO 5050 SL98600OOOO 6850 1
DH100 32-40 25 SL97205OOOO 5050 SL98601OOOO 6850 1
40-50 SL97206OOOO 5050 SL98602OOOO 6850 1
50-63 SL97207OOOO 5050 SL98603OOOO 6850 1
63-80 SL97208OOOO 5050 SL98604OOOO 6850 1
80-100 SL97209OOOO 5320 p SL98605OOOO 7210p 1
12-16 SL98644OOOO 6450 SL98611OOOO 7340 1
16-20 SL98645OOOO 6450 SL98612OOOO 7340 1
20-25 SL98646OOOO 6450 SL98613OOOO 7340 1
25-32 SL98647OOOO 6450 SL98614OOOO 7340 1
32-40 SL98648OOOO 6450 SL98615OOOO 7340 1
DH125 35
40-50 SL98649OOOO 6450 SL98616OOOO 7340 1
50-63 SL98650OOOO 6450 SL98617OOOO 7340 1
63-80 SL98651OOOO 6450 SL98618OOOO 7340 1
80-100 SL98652OOOO 7200 p SL98619OOOO 8210 p 1
100-125 SL98653OOOO 7340 p SL98607OOOO 8440 p 1
- Spreader Terminals are included

DL MCCB Range
l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Range: 16A to 100A, 3P & 4P
l Ics = 100% Icu
l Adjustable thermal setting: 0.8-1.0 x In
l Wide Range of Internal and External Accessories
l For Icu=65 kA, please contact branch office

Thermal Breaking 3 Pole 4 Pole


Std.
Release Capacity Icu M.R.P. M.R.P.
Type Pkg.
Range at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.)
(A) 50Hz. (kA) Per Unit Per Unit
12-16 SL97801OOOO 9750 SL98620OOOO 11190 1
16-20 SL97802OOOO 9750 SL98621OOOO 11190 1
20-25 SL97803OOOO 9750 SL98622OOOO 11190 1
25-32 SL97804OOOO 9750 SL98623OOOO 11190 1
DL100 32-40 50 SL97805OOOO 9750 SL98624OOOO 11190 1
40-50 SL97806OOOO 9750 SL98625OOOO 11190 1
50-63 SL97807OOOO 9750 SL98626OOOO 11190 1
63-80 SL97808OOOO 9750 SL98627OOOO 11190 1
80-100 SL97809OOOO 10780p SL98628OOOO 12340p 1

- Spreader Terminals are included

L&T, ESP 01.01.2015 37


DTH MCCB Range

l Conforms to IS/IEC 60947-2 & IEC 60947-2


l Suitable for distribution & induction furnace application
l Rugged construction
l Adjustable thermal setting : 600 - 800A
l Adjustable magnetic setting : 2600 - 6400A
3 Pole (for Induction Furnace Application)
Breaking
Current Instantaneous M.R.P. Std.
Capacity Icu
Type Rating Setting Cat. No. (`) Pkg.
at 415V,
(A) (A) Per Unit (Nos.)
3 Pole (for Distribution Application) 50Hz (kA)
Thermal Breaking 250 360 50 SB95052OOOO 40050 1
M.R.P. Std.
Type Release Capacity Icu Pkg. 400 550 50 SB95053OOOO 40050 1
Cat. No. (`) DTH800 -
Range at 415V, (Nos.)
Per Unit Instantaneous 630 850 50 SB95054OOOO 40050 1
(A) 50Hz (kA)
DTH800 600-800 50 SL94472OOOO 40050 1 800 1050 50 SB95055OOOO 40050 1

Accessories for DH100/DH125, DL100 MCCBs

Auxiliary Contact TAC Shunt Release UV Release Spreader Terminal Extended Rotary Handle
Internal External

Description M.R.P. Std. Description M.R.P. Std.


Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Auxiliary Contact Spreader Terminals
1 C/O - Right SL97296OOOO 765 1 3 Pole ST98047OOOO 350 Set of 6
1 C/O - Left SL97297OOOO 765 1 4 Pole ST98060OOOO 460 Set of 8
Trip Alarm Contact Rotary Handle
1 C/O - Right SL97298OOOO 765 1 Extended CM99103OOOO 1360 1
Shunt Release
Note: Phase Barriers are supplied along with MCCBs
110/240/415V AC - Left SL97299OMOO 1005 1
24V DC - Left SL97299O4OO 1005 1
Under Voltage Release
240V AC - Left SL97611OOOO 1345 1

Accessories for DTH 800 MCCBs

UV Release Shunt Release Auxiliary Contact Extended Rotary Handle

Internal External

Description M.R.P. Std. Description M.R.P. Std.


Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Auxiliary Contact Rotary Handle
2 C/O SL94217OOOO 1515 1 Extended CM99898OOOO 2530 1
Shunt Release Note: For (DTH800+TAC), please contact nearest branch office
415V AC, 220V DC - Right SL98526OOOO 1900 1
240V AC, 110V DC - Right SL98534OOOO 1900 1
Under Voltage Release
415V AC - Left SL98548OOOO 1900 1
240V AC - Left SL98545OOOO 1900 1
110V AC - Left SL98543OOOO 1900 1

38 L&T, ESP 01.01.2015


SS Enclosure for DU / DH

M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
DU100/DU100B/DU125U
ST98050OOOO 770 1
SS Enclosure
DU100D/DU100H SS Enclosure ST42021OOOO 770 1
DH100/DH125 SS Enclosure ST29967OOOO 1440 1
Note : Suitable for 3P MCCBs

DU SS Enclosure DH SS Enclosure

Ground Fault Module

l Provides protection against ground fault


l GF Module for ground fault protection can be used with all
Thermal Magnetic MCCBs
l Adjustable ground fault sensitivity selection: 10% - 50% of In
l Adjustable time delay: 100ms / 200ms
l Test facility to check healthiness of ground fault protection
system without tripping MCCB
l Suitable for 3 phase 3 wire & 3 phase 4 wire electrical
distribution network
l LED for earth fault indication

Ground Fault Protection

Range M.R.P. Std.


Type Cat. No. (`) CT Pkg.
(A)
Per Unit (Nos.)
GF1 100 - 200A ST27745OOOO 6035 Built in CBCT 1
GF2 250 - 400A ST27746OOOO 9175 Built in CBCT 1
GF11 up to 800A ST28594OOOO 5500 # External CT required 1

# External CTs of 5P10 class with secondary rating of 1A or 5A

L&T, ESP 01.01.2015 39


MCCB Range

New

DN4 DN3 DN3B DN2 DN1 DN0

With Thermal - Magnetic Release :

Rating (A)
20 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630
Icu (kA)
25/36 DN0
25/50 DN1
36 DN3B
36/50/70 DN2 DN3

l Conforms to IS/IEC 60947-2 & IEC 60947-2


l Range: 20A to 630A, 3P & 4P
l Choice of 25kA / 36kA / 50kA / 70kA breaking capacities
l Ics = 100% Icu*
l Suitable for Isolation
l Adjustable Over Load setting: 0.8 - 1.0 x In
l Adjustable Short Circuit setting: 6 - 10 x In**
l Manual, Rotary or Motorised versions available @
l Wide Range of snap fit Internal and External Accessories

Thermal Breaking 3 Pole 4 Pole


Capacity Icu Std.
Release M.R.P. M.R.P.
Type Pkg.
Range at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.)
(A) 50Hz. (kA) Per Unit Per Unit
For motor back-up
16-20 CM97893OOC2OG 5240 CM97919OOC2OG 6940 1
protection MCCB
20-25 CM97893OOD2OG 5240 CM97919OOD2OG 6940 1
please refer page no.45
25-32 CM97893OOE2OG 5240 CM97919OOE2OG 6940 1
32-40 CM97893OOF2OG 5240 CM97919OOF2OG 6940 1
DN0-100D* 36
40-50 CM97893OOG2OG 5240 CM97919OOG2OG 6940 1
50-63 CM97893OOH2OG 5240 CM97919OOH2OG 6940 1
63-80 CM97893OOJ2OG 5240 CM97919OOJ2OG 6940 1
80-100 CM97893OOK2OG 5240 CM97919OOK2OG 6940 1
100 - 125 CM98608OOLO 9660 CM98613OOLO 12420 1
125 - 160 CM98608OOMO 12440 CM98613OOMO 15290 1
DN1-250N* 50
160 - 200 CM98608OONO 16450 CM98613OONO 21170 1
200 - 250 CM98608OOPO 19280 CM98613OOPO 22930 1
16-20 CM91612OOCOOG 5680 CM91712OOCOOG 7780 1
20-25 CM91612OODOOG 5680 CM91712OODOOG 7780 1
25-32 CM91612OOEOOG 5680 CM91712OOEOOG 7780 1
32-40 CM91612OOFOOG 5680 CM91712OOFOOG 7780 1
DN0-100C
40-50 CM91612OOGOOG 5680 CM91712OOGOOG 7780 1
50-63 CM91612OOHOOG 5680 CM91712OOHOOG 7780 1
25
63-80 CM91612OOJOOG 5680 CM91712OOJOOG 7780 1
80-100 CM91612OOKOOG 5680 CM91712OOKOOG 7780 1
Note: Breaking Capacity :
100-125 CM90638OOLO 9000 CM90642OOLO 11700 1 C = 25kA, D = 36kA, N = 50kA, S = 70kA
New 125-160 CM90638OOMO 11800 CM90642OOMO 13800 1 @ Motorised version available for DN2 and
DN1-250C DN3 frames (please refer page No. 47)
160-200 CM90638OONO 15000 CM90642OONO 19500 1
* DN0-100D, DN1-250N: Ics = 50% Icu
200-250 CM90638OOPO 17800 CM90642OOPO 22300 1 **For DN0, DN1, DN3B-Short Circuit Setting: 9In

40 L&T, ESP 01.01.2015


MCCB Range
With Thermal - Magnetic Release :

For motor back-up


protection MCCB
please refer page no.45

Thermal Breaking 3 Pole 4 Pole


Capacity Icu Std.
Release M.R.P. M.R.P.
Type Pkg.
Range at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.)
(A) 50Hz. (kA) Per Unit Per Unit
100-125 CM92008OOL1OG 10190 CM92108OOL1OG 12470 1
125-160 CM92008OOM1OG 13090 CM92108OOM1OG 15390 1
DN2-250D
160-200 CM92009OON1OG 18380 CM92109OON1OG 22400 1
200-250 CM92009OOP1OG 20000 CM92109OOP1OG 23960 1
250-320 CM98401OOQOOG 21500 CM98403OOQOOG 27000 1
New DN3B-400D 36
320-400 CM98401OOROOG 21950 CM98403OOROOG 27440 1
250-320 CM94005OOQ1OG 23930 CM94105OOQ1OG 29980 1
DN3-400D
320-400 CM94005OOR1OG 24130 CM94105OOR1OG 30250 1
400-500 CM94006OOS1OG 26660 CM94106OOS1OG 33630 1
DN3-630D
500-630 CM94006OOT1OG 29590 CM94106OOT1OG 36190 1
100-125 CM92005OOL1OG 12790 CM92105OOL1OG 16560 1
125-160 CM92005OOM1OG 15700 CM92105OOM1OG 19140 1
DN2-250N
160-200 CM92006OON1OG 20560 CM92106OON1OG 25700 1
200-250 CM92006OOP1OG 22100 CM92106OOP1OG 26510 1
50
250-320 CM94003OOQ1OG 25050 CM94103OOQ1OG 30950 1
DN3-400N
320-400 CM94003OOR1OG 25130 CM94103OOR1OG 31380 1
400-500 CM94004OOS1OG 28700 CM94104OOS1OG 37130 1
DN3-630N
500-630 CM94004OOT1OG 31070 CM94104OOT1OG 39780 1
100-125 CM92002OOL1OG 18010 CM92102OOL1OG 20490 1
125-160 CM92002OOM1OG 21240 CM92102OOM1OG 25720 1
DN2-250S
160-200 CM92003OON1OG 24030 CM92103OON1OG 31510 1
200-250 CM92003OOP1OG 25180 CM92103OOP1OG 32270 1
70
250-320 CM94001OOQ1OG 28280 CM94101OOQ1OG 32650 1
DN3-400S
320-400 CM94001OOR1OG 28420 CM94101OOR1OG 32770 1
400-500 CM94002OOS1OG 36610 CM94102OOS1OG 44430 1
DN3-630S
500-630 CM94002OOT1OG 37790 CM94102OOT1OG 47160 1

Note: Breaking Capacity - C = 25kA, D = 36kA, N = 50kA, S = 70kA

General Information
l Use of phase barriers is mandatory. These are supplied along with MCCBs

l It is recommended to use spreader terminals for enhancing termination capacity

l Spreader terminals are available as accessories, unless otherwise specified against Cat. Nos.

Special Applications
l For DC application, 2P/3P/4P MCCBs are available
l For Capacitor back-up protection, MCCBs are available
l For Motor back-up protection, use M series of MCCBs such as DN0-M, DN1-M, DN2-M, DN3-M
l For isolation, use SD version (without protection release)

L&T, ESP 01.01.2015 41


MCCB Range
With Microprocessor Release :

Rating (A)
40 50 63 80 100 125 160 200 250 320 400 500 630 800 1000 1250
Icu (kA)

36/50/70 DN2 DN3


DN4
50/70

With Microprocessor Release MTX1.0 :


l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Range: 40A to 1250A, 3P & 4P
l Choice of 36kA / 50kA / 70kA breaking capacities
0.4 0.2
l Ics = 100% Icu

Inst
In 630A
l Suitable for Isolation
cut
l Adjustable Over Load from 0.4 - 1.0 x In

r
l Adjustable Short Circuit from 1.5 - 8 x Ir DN3
MTX1.0
l Inbuilt Instantaneous Protection
l Provision of Thermal Memory : ON/OFF
l Variable trip class at 7.2 Ir & 6 Ir
l Front LED indication of Over Load (Ready, Over load pre-alarm & Overload)
l Manual, Rotary or Motorised versions available @
l Wide Range of snap fit Internal and External Accessories

Breaking 3 Pole 4 Pole


Release Capacity Icu Std.
Type Range
at 415V AC,
M.R.P. M.R.P. Pkg. For motor back-up
(A) Cat. No. (`) Cat. No. (`) (Nos.)
50Hz. (kA) protection MCCB
Per Unit Per Unit
please refer page no.45
16 - 40 CM92063OOOOX1 13890 CM92155OOOOX1 17820 1
25 - 63 CM92071OOOOX1 13890 CM92154OOOOX1 17820 1
DN2-250D 40 - 100 CM92051OOOOX1 13890 CM92153OOOOX1 17820 1
63 - 160 36 CM92074OOOOX1 16990 CM92152OOOOX1 23060 1
100 - 250 CM92054OOOOX1 23120 CM92151OOOOX1 30160 1
DN3-400D 160 - 400 CM93001OOOOX1 27810 CM93003OOOOX1 34680 1
DN3-630D 250 - 630 CM93005OOOOX1 30230 CM93007OOOOX1 40470 1
16 - 40 CM92064OOOOX1 16500 CM92160OOOOX1 20300 1
25 - 63 CM92072OOOOX1 16500 CM92159OOOOX1 20300 1
DN2-250N 40 - 100 CM92052OOOOX1 16500 CM92158OOOOX1 20300 1
63 - 160 CM92075OOOOX1 20790 CM92157OOOOX1 25800 1
100 - 250 CM92055OOOOX1 25950 CM92156OOOOX1 33540 1
50
DN3-400N 160 - 400 CM93002OOOOX1 30560 CM93004OOOOX1 39040 1
DN3-630N 250 - 630 CM93006OOOOX1 33220 CM93008OOOOX1 43360 1
320 - 800 CM96021OOOOX1 52530 CM96111OOOOX1 65290 1
DN4-1250N 400 - 1000 CM96022OOOOX1 73570 CM96112OOOOX1 104390 1
500 - 1250 CM96023OOOOX1 90020 CM96113OOOOX1 133120 1
16 - 40 CM92065OOOOX1 18360 CM92165OOOOX1 23160 1
25 - 63 CM92073OOOOX1 18360 CM92164OOOOX1 23160 1
DN2-250S 40 - 100 CM92059OOOOX1 18360 CM92163OOOOX1 23160 1
63 - 160 CM92076OOOOX1 24760 CM92162OOOOX1 31600 1
100 - 250 CM92056OOOOX1 30600 CM92161OOOOX1 35840 1
70
DN3-400S 160 - 400 CM94053OOOOX1 36440 CM94153OOOOX1 45810 1
DN3-630S 250 - 630 CM94079OOOOX1 39600 CM94179OOOOX1 50660 1
320 - 800 CM96025OOOOX1 63320 CM96115OOOOX1 77940 1
DN4-1250S 400 - 1000 CM96026OOOOX1 90940 CM96116OOOOX1 129940 1
500 - 1250 CM96027OOOOX1 113430 CM96117OOOOX1 155870 1

@ Motorised version available for DN2 and DN3 frames (please refer page No. 47)

42 L&T, ESP 01.01.2015


MCCB Range
With Microprocessor Release MTX2.0 :
l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Range: 40A to 1250A, 3P & 4P
l Choice of 36kA / 50kA / 70kA breaking capacities 0.4 0.2 Ir *

Ics = 100% Icu

r
l

Inst
In 630A
l Suitable for Isolation
l Adjustable Over Load from 0.4 - 1.0 x In

0.5
1.0
r
DN3
l Adjustable Short Circuit from 1.5 - 8 x Ir MTX2.0
l Inbuilt Instantaneous Protection
l Inbuilt ground fault protection from 20% - 50% of In
l Adjustable neutral overload protection available : 50% to 150% of Ir
l Provision of Thermal Memory : ON/OFF
l Variable trip class at 7.2 Ir & 6 Ir
l Front LED indication of Over Load (Ready, Over load pre-alarm & Overload)
l Panel mounted display available for Current metering & trip record
l Manual, Rotary or Motorised versions available @
l For 3 phase 4 wire system, External neutral CTs available for 3P MCCBs
l Wide Range of snap fit Internal and External Accessories

Breaking 3 Pole 4 Pole


Release Capacity Icu Std.
Type Range M.R.P. M.R.P. Pkg.
(A) at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.) For motor back-up
50Hz. (kA) Per Unit Per Unit protection MCCB
16 - 40 CM92063OOOOAG 24170 CM92155OOOOAG 28070 1 please refer page no.45
25 - 63 CM92071OOOOAG 24170 CM92154OOOOAG 28070 1
DN2-250D 40 - 100 CM92051OOOOAG 24170 CM92153OOOOAG 28070 1
63 - 160 36 CM92074OOOOAG 27680 CM92152OOOOAG 34320 1
100 - 250 CM92054OOOOAG 32720 CM92151OOOOAG 40270 1
DN3-400D 160 - 400 CM93001OOOOAG 38560 CM93003OOOOAG 45080 1
DN3-630D 250 - 630 CM93005OOOOAG 41540 CM93007OOOOAG 51410 1
16 - 40 CM92064OOOOAG 26510 CM92160OOOOAG 30590 1
25 - 63 CM92072OOOOAG 26510 CM92159OOOOAG 30590 1
DN2-250N 40 - 100 CM92052OOOOAG 26510 CM92158OOOOAG 30590 1
63 - 160 CM92075OOOOAG 31350 CM92157OOOOAG 37360 1
100 - 250 CM92055OOOOAG 34610 CM92156OOOOAG 43400 1
50
DN3-400N 160 - 400 CM93002OOOOAG 40060 CM93004OOOOAG 47800 1
DN3-630N 250 - 630 CM93006OOOOAG 44320 CM93008OOOOAG 57290 1
320 - 800 CM96021OOOOAG 70410 CM96111OOOOAG 81240 1
DN4-1250N 400 - 1000 CM96022OOOOAG 90070 CM96112OOOOAG 120530 1
500 - 1250 CM96023OOOOAG 105490 CM96113OOOOAG 150960 1
16 - 40 CM92065OOOOAG 29370 CM92165OOOOAG 34000 1
25 - 63 CM92073OOOOAG 29370 CM92164OOOOAG 34000 1
DN2-250S 40 - 100 CM92059OOOOAG 29370 CM92163OOOOAG 34000 1
63 - 160 CM92076OOOOAG 36880 CM92162OOOOAG 44770 1
100 - 250 CM92056OOOOAG 41380 CM92161OOOOAG 49670 1
70
DN3-400S 160 - 400 CM94053OOOOAG 46860 CM94153OOOOAG 57500 1
DN3-630S 250 - 630 CM94079OOOOAG 53120 CM94179OOOOAG 72990 1
320 - 800 CM96025OOOOAG 79490 CM96115OOOOAG 93430 1
DN4-1250S 400 - 1000 CM96026OOOOAG 109310 CM96116OOOOAG 146250 1
500 - 1250 CM96027OOOOAG 127260 CM96117OOOOAG 173600 1
@ Motorised version available for DN2 and DN3 frames (please refer page No. 47)

M.R.P.
Modules for MTX2.0 release Cat. No. (`)
Per Unit
Current Metering Module Current Metering &
CM95698OOOO 10000 latest trip record
(Display & Metering Module)
Cable (2m length) CM01196OOOO 1000
Power Supply Module CL90722OOOO *
UNCO Module for Status
Indication & Control through CL90852OOOO 9000
communication
Display Metering
Module Module
* Available on request
MTX2.0 with current metering module

L&T, ESP 01.01.2015 43


MCCB Range
With Microprocessor Release MTX3.0 :
l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Range: 40A to 1250A, 3P & 4P
In 630A
l Choice of 36kA / 50kA / 70kA breaking capacities
New
l Ics = 100% Icu

0.5
1.0
1.5
0.3
DN3 A4 A3 A2 A1
l Suitable for Isolation MTX 3.0
l Adjustable Over Load from 0.4 - 1.0 x In
l Adjustable Short Circuit from 1.5 - 8 x Ir with selectable time delay
l Instantaneous protection with fine settings
l Inbuilt ground fault protection from 10% - 50% of In
l Adjustable neutral overload protection available : 50% to 150% of Ir
l Advanced Current, Voltage, Frequency & Power based protections
l Other Protections like Maximum Demand, Phase Sequence, THD etc.
l Comprehensive Current, Power, Energy, PF, MD, THD metering
l Provision of Thermal Memory : ON/OFF
l Variable trip class at 1.5 Ir,6 Ir & 7.2 Ir
l Front LED indication of Over Load (Ready, Over load pre-alarm & Overload)
l Panel mounted display available for advanced protections & metering
l Communication capable release
l Manual, Rotary or Motorised versions available @
l For 3 phase 4 wire system, External neutral CTs available for 3P MCCBs
l Wide Range of snap fit Internal and External Accessories

Breaking 3 Pole 4 Pole


Release Capacity Icu Std.
Type Range M.R.P. M.R.P. Pkg.
(A) at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.)
50Hz. (kA) Per Unit Per Unit
16 - 40 CM92063OOOOBG CM92155OOOOBG 1
25 - 63 CM92071OOOOBG CM92154OOOOBG 1
DN2-250D 40 - 100 CM92051OOOOBG CM92153OOOOBG 1
63 - 160 36 CM92074OOOOBG CM92152OOOOBG 1
100 - 250 CM92054OOOOBG CM92151OOOOBG 1
DN3-400D 160 - 400 CM93001OOOOBG CM93003OOOOBG 1
DN3-630D 250 - 630 CM93005OOOOBG CM93007OOOOBG 1
16 - 40 CM92064OOOOBG CM92160OOOOBG 1
25 - 63 CM92072OOOOBG CM92159OOOOBG 1
DN2-250N 40 - 100 CM92052OOOOBG CM92158OOOOBG 1
63 - 160 CM92075OOOOBG CM92157OOOOBG 1
100 - 250 CM92055OOOOBG CM92156OOOOBG 1
50
DN3-400N 160 - 400 CM93002OOOOBG CM93004OOOOBG 1
DN3-630N 250 - 630 CM93006OOOOBG CM93008OOOOBG 1
320 - 800 CM96021OOOOBG CM96111OOOOBG 1
DN4-1250N 400 - 1000 CM96022OOOOBG CM96112OOOOBG 1
500 - 1250 CM96023OOOOBG CM96113OOOOBG 1
16 - 40 CM92065OOOOBG CM92165OOOOBG 1
25 - 63 CM92073OOOOBG CM92164OOOOBG 1
DN2-250S 40 - 100 CM92059OOOOBG CM92163OOOOBG 1
63 - 160 CM92076OOOOBG CM92162OOOOBG 1
100 - 250 CM92056OOOOBG CM92161OOOOBG 1
70
DN3-400S 160 - 400 CM94053OOOOBG CM94153OOOOBG 1
DN3-630S 250 - 630 CM94079OOOOBG CM94179OOOOBG 1
320 - 800 CM96025OOOOBG CM96115OOOOBG 1
DN4-1250S 400 - 1000 CM96026OOOOBG CM96116OOOOBG 1
500 - 1250 CM96027OOOOBG CM96117OOOOBG 1
MCCB with MTX3.0 release
@ Motorised version available for DN2 and DN3 frame.

M.R.P. Power Supply


Modules for MTX3.0 release Cat. No. (`) Module
Per Unit
Communication Module CM95680OOOO
Voltage Module CM95685OOOO
Display Module CM95676OOOO Voltage
Display Module
Power Supply Module CL90722OOOO Module
Communication 3 ph 4 wire
UNCO Module for Status Indication & AC supply
Control through communication CL90852OOOO 9000 Module

* Available on request MTX3.0 with all modules

44 L&T, ESP 01.01.2015


MCCB Range
Switch Disconnector - SD (MCCBs without protection release):

l Used as switching devices for isolation PCC


l Range: 32A to 1250A, 3P & 4P DG
Transformer
l Suitable for isolation
l Wide Range of snap fit Internal and External Accessories CB-1 MCCB-5 as Isolator CB-2

3 Pole 4 Pole
Current Std.
Type Rating M.R.P. M.R.P. Pkg. CB-3 CB-4
(A) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit
32 CM90716OOEO 4500 CM90717OOEO 5850 1
63 CM90716OOHO 4500 CM90717OOHO 5850 1
New DN0-160SD 100 CM90716OOKO 5450 CM90717OOKO 7090 1
125 CM90716OOLO 5950 CM90717OOLO 7740 1 MCC
160 CM90716OOMO 6450 CM90717OOMO 8390 1
MCCB-6 as Isolator
200 CM96814OONOOG 13510 CM96815OONOOG 16250 1
DN2-250SD
250 CM96802OOPOOG 13870 CM96803OOPOOG 17210 1
320 CM98410OOQOOG 16000 CM98412OOQOOG 20800 1
New DN3B-400SD SCPD-1 SCPD-2
400 CM98410OOROOG 18000 CM98412OOROOG 22500 1
320 CM96804OOQOOG 18320 CM96805OOQOOG 25060 1 Starter-1 Starter-2
DN3-400SD
400 CM96804OOROOG 20010 CM96805OOROOG 26170 1
500 CM96806OOSOOG 21580 CM96807OOSOOG 28190 1 M M
DN3-630SD
630 CM96806OOTOOG 22240 CM96807OOTOOG 29830 1
Representative Application Image
800 CM93041OOUO 51430 CM93042OOUO 64820 1
DN4-1250SD 1000 CM93041OOVO 64340 CM93042OOVO 83430 1
1250 CM93041OOAO 79580 CM93042OOAO 111440 1

MCCBs for Motor back-up Protection: MCCB

l Range: 32A to 630A, 50kA Starter

l Suitable for isolation


l Wide Range of snap fit Internal and External Accessories
M Representative Application Image

3 Pole 3 Pole
Breaking Breaking
Current M.R.P. Std. Current M.R.P. Std.
Capacity Icu Capacity Icu
Type Rating Cat. No. (`) Pkg. Type Rating Cat. No. (`) Pkg.
at 415V. AC, at 415V. AC,
(A) Per Unit (Nos.) (A) Per Unit (Nos.)
50Hz. (kA) 50Hz. (kA)
32 CM98944OOEO 4690 1 200 CM92171OONOOG 12940 1
DN2-250M
40 CM98944OOFO 4690 1 250 CM92171OOPOOG 16640 1
50 CM98944OOGO 4690 1 320 CM94516OOQOOG 19720 1
DN0-100M DN3-400M 50
63 CM98944OOHO 4690 1 400 CM94516OOROOG 20890 1
80 50 CM98944OOJO 4690 1 500 CM94515OOSOOG 24620 1
DN3-630M
100 CM98944OOKO 4690 1 630 CM94515OOTOOG 25030 1
100 CM90345OOKO 7500 1 Note: Please contact nearest branch office for fuseless type 2 co-ordination
New DN1-160M 125 CM90345OOLO 8000 1 selection chart
160 CM90345OOMO 9500 1

L&T, ESP 01.01.2015 45


Automatic Source Transfer System
l Stored Energy operated
l Automatic / Manual control of power supply source
l Set-up data programming
l Virtual front panel viewing with key activation feature
l Programmable I/Os
l Test function
l LED display
l Voltage and Frequency display
l Inbuilt UV protection
AuXC-1000L
l Inbuilt phase unbalance protection

2 MCCBs + 2 SE-EOM + 2 UV + 1 MIL kit

ASTS with Thermal - Magnetic Releases Auto Source Transfer Controller

Breaking 3 Pole 4 Pole M.R.P.


Type Std. Pkg.
Current Capacity Icu Cat. No. (`)
Frame M.R.P. M.R.P. (Nos.)
Rating at 415V AC, Per Unit
(A) (`) (`)
50Hz. (kA) Per Unit Per Unit AuXC-1000L ST80024OOOO 43770 1

100 113230 117970 AuXC-1000 ST80230OOOO 52745 1


DN2 160 36 120130 124730 Can be used along with , MCCBs, MCX contactors & Motorized
250 133950 141870 Changeover switches
100 116930 122770
DN2 160 125350 132230
250 50 138150 146970
400 154165 166665
DN3
630 166045 183465
160 136430 145390
DN2
250 144310 158490
70
400 160745 169445
DN3
630 179485 198225

ASTS with Microprocessor Release MTX1.0 ASTS with Microprocessor Release MTX2.0

Breaking 3 Pole 4 Pole Breaking 3 Pole 4 Pole


Current Capacity Icu Current Capacity Icu
Frame Rating M.R.P. M.R.P. Frame Rating M.R.P. M.R.P.
at 415V AC, at 415V AC,
(A) (`) (`) (A) (`) (`)
50Hz. (kA) 50Hz. (kA)
Per Unit Per Unit Per Unit Per Unit
100 121730 129590 100 142290 150090
DN2 160 36 127930 140070 DN2 160 36 149310 162590
250 140190 154270 250 159390 174490
100 126950 134550 100 146970 155130
DN2 160 135530 145550 DN2 160 156650 168670
250 50 145850 161030 250 50 163170 180750
400 165025 181985 400 184025 199505
DN3 DN3
630 170345 190625 630 192545 218485
160 143470 157150 160 167710 183490
DN2 DN2
250 155150 165630 250 176710 193290
70 70
400 176785 195525 400 197625 218905
DN3 DN3
630 183105 205225 630 210145 249885

ASTS MRP consists of the following products: 2 dsine MCCBs, 2 SE-EOMs, 2 UV release, 2 Aux + Trip Alarm contact, 1 MIL Kit & 1 AuXC-1000L Controller
For AuXC-1000 please add ` 8975 to the above MRP

Note: Picture shown is for representation purpose only, MCCB + EOM + UV combination, MIL kit & AuXC-1000L to be purchased separately & assembled at site.

46 L&T, ESP 01.01.2015


Accessories for MCCBs

Auxiliary Contact TAC Shunt Release UV Release


Internal Direct Rotary Handle Extended Rotary Handle Key Lock
Description M.R.P. Std. External
Cat. No. (`) Pkg. M.R.P. Std.
Description
Per Unit (Nos.) Cat. No. (`) Pkg.
Auxiliary Contact Per Unit (Nos.)
Rotary Handle
DN0, DN1 - 1 C/O - Right CM97886OOOO 695 1
DN0 Direct CM97895OOOO 950 1
DN0, DN1 - 2 C/O - Right CM97887OOOO 1240 1
DN1 Direct CM98040OOOO 1015 1
DN2, DN3B, DN3, DN4 - 1 C/O CM99801OOOO 790 1
DN2 Direct CM99829OOOO 1025 1
DN2, DN3B, DN3, DN4 - 2 C/O CM99802OOOO 1350 1
DN3B, DN3 Direct CM99860OOOO 1560 1
Trip Alarm Contact
DN0 Extended CM97896OOOO 1410 1
DN0, DN1 - 1 C/O - Right CM97888OOOO 695 1
DN1 Extended CM98041OOOO 1450 1
DN0, DN1 - 2 C/O - Right CM97889OOOO 1240 1
DN2 Extended CM99830OOOO 1535 1
DN2, DN3B, DN3, DN4 - 1 C/O - Right CM99803OOOO 790 1
DN3B, DN3 Extended CM99861OOOO 2495 1
Auxiliary 1 C/O + TAC 1 C/O
DN4 Extended CM99884OOOO 3485 1
DN0, DN1 - Right CM97890OOOO 1240 1
DN2, DN3B, DN3, DN4 - Right CM99804OOOO 1515 1 Panel door mounted Key lock for
Extended Rotary Handle #
Shunt Release
Type 1 CM99958TOOOO 1355 1
DN0, DN1 - 240/415V AC - Left CM97883OMOO 1040 1
Type 2 CM99958TOOOA 1355 1
DN2, DN3B, DN3, DN4 -110/240/415V AC,
CM99805OOOO 1860@ 1 Type 3 1
110/220V DC CM99958TOOOB 1355
New DN2, DN3B, DN3, DN4 - 24V DC CM98976O4OO 1860@ 1 Type 12 CM99958TOOOC 1355 1
Under Voltage Release Type 23 CM99958TOOOD 1355 1
DN0, DN1 - 240V AC - Left CM97892BOOO 1395 1 # - Can be used with dsine, DU, DH/DL, DTH new look extended ROM
DN2, DN3B, DN3 - 240V AC - Left CM99986BOOO 2210** 1
DN4 - 240V AC - Left CM99906OOOO 2420** 1
@ - NO of control contactor to be connected in series for DC control supply
** - Use these UV Cat. Nos. with Grey look MCCBs only

Spreader MIL Kit - Base


Stored Energy EOM Neutral CT Adaptor kit for NCT Terminals Mounted
External External
Description M.R.P. Std. Description M.R.P. Std.
Cat. No. (`) Pkg. Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Stored Energy Electrical Operating Mechanism Spreader Terminals
DN2 - 240V AC 1 DN0-100 - 3 Pole CM97785OOOO 220 Set of 6
DN3 - 240V AC 1 DN1, DN2 - 250 - 3 Pole ST98053OOOO 1160 Set of 6
External Neutral CT DN3B/DN3-400 - 3 Pole ST98065OOOO 2000 Set of 6
DN2 - 40A CM99946OOOO 1400 1 DN3-630 - 3 Pole ST98054OOOO 2250 Set of 6
DN2 - 63A CM99947OOOO 1400 1 DN4-800 - 3 Pole ST90361OOOO 4565 Set of 6
DN2 - 100A CM99948OOOO 1400 1 DN4-1000 - 3 Pole CM90063OOVO 9130 Set of 12
DN2 - 160A CM99949OOOO 2000 1 DN4-1250 - 3 Pole ST98055OOOO 16530 Set of 6
DN2 - 250A CM99950OOOO 2000 1 DN0-100 - 4 Pole CM97921OOOO 320 Set of 8
DN3 - 400A CM99954OOOO 3700 1 DN1, DN2 - 250 - 4 Pole CM92007OOOO 1410 Set of 8
DN3 - 630A CM99955OOOO 3700 1 DN3B/DN3-400 - 4 Pole ST98066OOOO 2875 Set of 8
DN4 - 800A CM99889OOOO 5500 1 DN3-630 - 4 Pole CM92004OOOO 3375 Set of 8

DN4 - 1000A CM99890OOOO 5500 1 DN4-800 - 4 Pole ST90362OOOO 5945 Set of 8

DN4 - 1250A CM99891OOOO 5500 1 DN4-1000 - 4 Pole CM90064OOVO 11890 Set of 16


Adaptor kit for External Neutral CT DN4-1250 - 4 Pole ST98058OOOO 21830 Set of 8

DN2 - 250 CM99994OOOO 450 Set of 2 Mechanical Interlock Kit - Base Mounted
DN3 - 400 CM99995OOOO 940 Set of 2 DN2-250 CM99731OOOO 3760 1
DN3 - 630 CM99997OOOO 950 Set of 2 DN3-400 CM99732OOOO 5715 1
DN4 - 800 CM99996OOOO 1600 Set of 2 DN3-630 CM99854OOOO 5715 1
DN4 - 1000 CM90966OOOO 3200 Set of 4 DIN rail kit
DN4 - 1250 CM99998OOOO 5950 Set of 2 DN0 CM90944OOOO 50 1
- Including indicator Assembly (Aux + TAC) Note: Phase Barriers are supplied along with MCCBs
* Available on request

L&T, ESP 01.01.2015 47


SMDBs for Power Distribution
Features
l Compliance with latest standard - IEC 61439-2 l Ready to use, off the shelf solution
l Rating upto 630 A l Choice of number of outgoing ways of 4,8 and 12
l Higher withstand capacity upto 36 kA for 1 s l Ingress protection upto IP 43
l Metering & cabling extensions are available as add-ons

Ordering Details
M.R.P. Height (H) Width (W) Depth (D)
Description Cat. No. (`) (mm) (mm) (mm)
Per Unit
SMDB TN250D, O/G 100A 4 ways DA20D1044CZZ0 38000 637 670 208.5
SMDB TN250D, O/G 100A 8 ways DA20D1084CZZ0 46000 787 670 208.5
SMDB TN250D, O/G 100A 12 ways DA20D1124CZZ0 59000 937 670 208.5
SMDB TN400D, O/G 100A 4 ways DA40D1044CZZ0 43000 937 670 208.5
SMDB TN400D, O/G 100A 8 ways DA40D1084CZZ0 49000 1084 670 208.5
SMDB TN400D, O/G 100A 12 ways DA40D1124CZZ0 63000 1237 670 208.5
SMDB TN630D, O/G 100A 4 ways DA60D1044CZZ0
SMDB TN630D, O/G 100A 8 ways DA60D1084CZZ0 * Available on request
SMDB TN630D, O/G 100A 12 ways DA60D1124CZZ0

Note: While ordering SMDB, incoming and outgoing MCCBs have to be ordered separately. Prices of MCCBs are not included in SMDB prices.

READY-TO-USE POWER
DISTRIBUTION SOLUTION

Enersys-S from L&T is Sub Main Distribution board that complies with IEC 61439-2 and certified by DEKRA. This Sub Main Distribution board
used for power distribution which is designed for easy handling and simple installation. It also offers safe, reliable and higher performance.

48 L&T, ESP 01.01.2015


Air Circuit Breakers

Range of Air Circuit Breakers

l Complete range conforms to IS/IEC 60947-2 & IEC 60947-2


l Current rating from 400A to 6300A in 3 frame sizes
l Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed/Draw-out version
l Common Height & Depth across the range
l High short time fault withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
l High mechanical and electrical operating life
l Neutral pole is 100% rated, option of 50% & 200% rated neutral also available
l Available in both NRYB & RYBN configuration in 4 Pole ACBs with on-site change facility
l In-built Electrical & Mechanical Anti-Pumping
l Modular & snap-fit accessories
l Ease of on-site conversion from Fixed to Draw-out version

Matrix Protection & Control units:


l Available in versions - MTX1.0/1G/1.5G, MTX2.5/2.5G,
MTX3.5/3.5EC & MTX4.5
l Unique O-LED display for metering UW-MTX1.0 UW-MTX1G UW-MTX1.5G
l Touch screen technology in UW-MTX4.5
l Unique withdrawable Communication & Power metering modules
l Dual protection curve settings & Password protection
l Soft-rating plug for precise protection at lower load currents
l Provision for on-load self-diagnosis of Releases & modules
l Data communication on Modbus, Profibus & wireless Zigbee protocols
l Power & Harmonics measurement
l Temperature rise monitoring & protection
l Easy to integrate with HMI & PLC
l Add-on modules for advance protection
l Protection Releases conform to EMI/EMC standard

UW-MTX2.5/2.5G UW-MTX3.5/3.5EC UW-MTX4.5

Breaking Capacities offered:


Icu = Ics = Icw for 1 sec
800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
N : 50kA
Frame-1

S : 65kA
H : 80kA
UW1-08 UW1-10 UW1-12 UW1-16 UW1-20 UW1-25
S : 65kA
Frame-2

H : 80kA
UW2-08 UW2-10 UW2-12 UW2-16 UW2-20 UW2-25 UW2-32
H : 80kA
Frame-3

V : 100kA

UW3-08 UW3-10 UW3-12 UW3-16 UW3-20 UW3-25 UW3-32 UW3-40 UW3-50 UW3-63
Note: 400A & 630A ACBs are also available on request.

L&T, ESP 01.01.2015 49


U-POWER Air Air
Circuit Breakers
Circuit Breakers
OMEGA
ACB ordering information:

UW 1 08 N X D 1 2 9 0 0 OMEGA 800A Fr-1 50kA 3P EDO UW-MTX1.5G

(3)
Temperature Rise Monitoring
Not Required 0
Required 1

Selection for P&C Units


B/C (w/o protection) 0
UW - MTX1.0 7
Frame Size UW - MTX1G 8
Frame - I 1 UW - MTX1.5G 9
Frame - II 2 UW - MTX2.5 1
Frame - III 3 UW -MTX2.5G 2
UW-MTX3.5 3
UW-MTX3.5EC 4
UW-MTX4.5 5
Current Ratings
400A 04 Type
Manually Operated 1
630A 06
Electrically Operated 2
800A 08
1000A 10
1250A 12 Selection for control voltage
(2)

1600A 16 For Manually Operated 0


2000A 20 240V AC ECD & CR & 240V AC SR 1
2500A (4) 25 240V AC ECD & CR & 24V DC SR 2
3200A 32
4000A 40
5000A 50 Version
6300A 63 Draw-out D
Fixed F

(1) Selection for No. of Poles


Selection for Breaking Capacity (Icu=Ics)
3 Pole X
50kA (Fr-I upto 1600A) N 4 Pole 100% N F
65kA (Fr-I & Fr-II) S 4 Pole 50% N (in Fr-III only) H
80kA (Fr-l, Fr-II & Fr-III) H 4 Pole 200% N (upto 2500A) D
100kA (Fr-III) V
Please Note :
(1)
For Icw values please refer product catalogue
(2)
Other options of control voltage are available as accessory
(3)
Temperature protection is available in UW-MTX3.5/3.5EC/4.5
(4)
For Fr-1, 2500A selection, please contact the nearest branch office

ACBs are offered with following standard features :


Draw-out version : Omega ACBs with UW-MTX release will have inbuilt-
Current Metering (MTX 1.5G/2.5/2.5G/3.5/3.5EC/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Smart-racking
shutter, Safety shutter assembly, Racking Handle, Door sealing frame, Pad-locking arrangement for ON/OFF button, Rating Error Preventer,
Arc shield (with frame 1N, 2S & 3H version)
A) For ratings upto 1600A, one side vertical terminal adaptors (Bottom).
B) For ratings 2000A & above, both side vertical terminal adaptors (Top & Bottom).
C) For ratings 4000A & above, operation counter inbuilt
Fixed Version : Omega ACBs with UW-MTX release will have inbuilt-
Current Metering (MTX 1.5G/2.5/2.5G/3.5/3.5EC/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Door sealing frame &
Pad-locking arrangement for ON/OFF button.
For ratings 4000A & above, operation counter inbuilt
Electrically operated ACB includes ECD (240V AC), CR (240V AC) & SR (240V AC or 24V DC).

50 L&T, ESP 01.01.2015


Air Circuit Breakers

3 Pole ACBs with UW-MTX1.5G (LSING + Current Metering)

3 Pole Manual Draw-out ACB with UW-MTX1.5G


Current N (50kA) S (65kA) H (80kA) V (100kA)
Rating Version
M.R.P. M.R.P. M.R.P. M.R.P.
Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NXD01900 UW108SXD01900 UW108HXD01900 UW308VXD01900
1000A UW110NXD01900 UW110SXD01900 UW110HXD01900 UW310VXD01900
1250A UW112NXD01900 UW112SXD01900 UW112HXD01900 UW312VXD01900
1600A UW116NXD01900 UW116SXD01900 UW116HXD01900 UW316VXD01900
2000A - - UW120SXD01900 UW120HXD01900 UW320VXD01900
MDO
2500A - - UW225SXD01900 UW225HXD01900 UW325VXD01900
3200A - - UW232SXD01900 UW232HXD01900 UW332VXD01900
4000A - - - - UW340HXD01900 UW340VXD01900
5000A - - - - UW350HXD01900 UW350VXD01900
6300A - - - - UW363HXD01900 UW363VXD01900

3 Pole Manual Fixed ACB with UW-MTX1.5G


Current N (50kA) S (65kA) H (80kA) V (100kA)
Rating Version
M.R.P. M.R.P. M.R.P. M.R.P.
Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NXF01900 UW108SXF01900 UW108HXF01900 UW308VXF01900
1000A UW110NXF01900 UW110SXF01900 UW110HXF01900 UW310VXF01900
1250A UW112NXF01900 UW112SXF01900 UW112HXF01900 UW312VXF01900
1600A UW116NXF01900 UW116SXF01900 UW116HXF01900 UW316VXF01900
2000A - - UW120SXF01900 UW120HXF01900 UW320VXF01900
MF
2500A - - UW225SXF01900 UW225HXF01900 UW325VXF01900
3200A - - UW232SXF01900 UW232HXF01900 UW332VXF01900
4000A - - - - UW340HXF01900 UW340VXF01900
5000A - - - - UW350HXF01900 UW350VXF01900
6300A - - - - UW363HXF01900 UW363VXF01900

M.R.P.
M.R.P. changes for product customization (`)
Per Unit
MDO to EDO or MF to EF conversion (Includes ECD 240V AC, CR 240V AC & SR 240V AC or 24V DC)
Buscoupler (without protection release)
UW-MTX1.0 (LSI - BCD Switches)
UW-MTX1G (LSING - BCD Switches)
UW-MTX3.5 (LSING + Current Metering) - can be upgraded for Power Metering & Communication
UW-MTX3.5EC (LSING + Power Metering + Communication)
UW-MTX4.5 (LSING + Power Metering + Communication with Touch Screen navigation + UW-PS Module)
UW-PS, Auxiliary power supply module for display in No-load or OFF condition
COM Module (MODBUS) for communication
PM Module for power metering

* Available on request

L&T, ESP 01.01.2015 51


Air Circuit Breakers

4 Pole ACBs with UW-MTX1.5G (LSING + Current Metering)

4 Pole Manual Draw-out ACB with UW-MTX1.5G


Current N (50kA) S (65kA) H (80kA) V (100kA)
Rating Version
M.R.P. M.R.P. M.R.P. M.R.P.
Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NFD01900 UW108SFD01900 UW108HFD01900 UW308VFD01900
1000A UW110NFD01900 UW110SFD01900 UW110HFD01900 UW310VFD01900
1250A UW112NFD01900 UW112SFD01900 UW112HFD01900 UW312VFD01900
1600A UW116NFD01900 UW116SFD01900 UW116HFD01900 UW316VFD01900
2000A - - UW120SFD01900 UW120HFD01900 UW320VFD01900
MDO
2500A - - UW225SFD01900 UW225HFD01900 UW325VFD01900
3200A - - UW232SFD01900 UW232HFD01900 UW332VFD01900
4000A - - - - UW340HFD01900 UW340VFD01900
5000A - - - - UW350HFD01900 UW350VFD01900
6300A - - - - UW363HFD01900 UW363VFD01900

4 Pole Manual Fixed ACB with UW-MTX1.5G


Current N (50kA) S (65kA) H (80kA) V (100kA)
Rating Version
M.R.P. M.R.P. M.R.P. M.R.P.
Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NFF01900 UW108SFF01900 UW108HFF01900 UW308VFF01900
1000A UW110NFF01900 UW110SFF01900 UW110HFF01900 UW310VFF01900
1250A UW112NFF01900 UW112SFF01900 UW112HFF01900 UW312VFF01900
1600A UW116NFF01900 UW116SFF01900 UW116HFF01900 UW316VFF01900
2000A - - UW120SFF01900 UW120HFF01900 UW320VFF01900
MF
2500A - - UW225SFF01900 UW225HFF01900 UW325VFF01900
3200A - - UW232SFF01900 UW232HFF01900 UW332VFF01900
4000A - - - - UW340HFF01900 UW340VFF01900
5000A - - - - UW350HFF01900 UW350VFF01900
6300A - - - - UW363HFF01900 UW363VFF01900

Auto Source Transfer Controller


M.R.P.
Type Cat. No. (`) Std. Pkg. (Nos.)
Per Unit
AuXC-1000L ST80024OOOO 43770 1
AuXC-1000 ST80230OOOO 52745 1
Can be used along with , MCCBs, MCX contactors & Motorized
For Energy Management Changeover switches
Communication Software
Please contact the nearest
Features
branch office
l Remote Status & Control of ACB
l Communicates on MODBUS Protocol
l Inbuilt RS485 Port
UN-CO module
M.R.P.
Description Cat. No. Qty (`)
Per Unit
UN-CO module for Breaker control CL90852OOOO 1 9000

* Available on request
52 L&T, ESP 01.01.2015
Accessories of Air Circuit Breakers

Operation Counter Door Interlock Closing Release Shunt Release UV Release

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Operation Counter CL90983OOOO Electrical Charging Device (ECD)
Door Interlock CL90978OOOO 24-30V DC CL90362OOOO

Electrical Position Indication (EPI) CL95826OOOO 110V AC / 110-125V DC CL90360OOOO

Microswitch for Common Fault Indication (CFI) CL90949OOOO 220V AC / 200V DC CL90364OOOO

Microswitch for Ready To Close Indication (RTC) CL90953OOOO 240V AC / 250V DC CL90359OOOO

Microswitch for Shunt Release CL90951OOOO 415V AC / 400V DC CL90361OOOO

Microswitch for Undervoltage Release CL90947OOOO Closing Release (CR)

Microswitch for Spring Charging Indication ST42672OOOO 24-30V DC CL908174OOO

110V AC & DC CL90817AOOO

240V AC / 220 - 250V DC CL90817BOOO

415V AC CL90817DOOO

Shunt Release (SR)

24-30V DC CL90816O4OO

110V AC / 110V DC CL90816OAOO

240V AC / 220 - 250V DC CL90816OBOO


R-Lock C-Lock
415V AC CL90816ODOO
M.R.P.
Description Cat. No. (`) Under Voltage Release (UVR) with time delay (0-1-3-5 sec)
Per Unit 24-30V DC CL908184OOO
Mechanical Interlock using Key & Lock
110V AC CL90818AOOO
R - Lock Type - 1 CL00659OOOO 240V AC (DG application) ST42745OOOO
R - Lock Type - 2 CL00660OOOO 240V AC CL90818BOOO
R - Lock Type - 3 CL00661OOOO 415V AC CL90818DOOO
R - Lock Type - 12 CL00662OOOO

R - Lock Type - 23 CL00663OOOO

Locking arrangement for OFF button


CL90815OOOO
with R - Lock (on breaker)

Locking arrangement for ISO position


CL90865OOOO
with R - Lock (on Cradle)

Locking arrangement for ANY position


CL90927OOOO
with R - Lock (on Cradle)

C - Lock Type - S CL00664OOOO


C - Lock Type - T CL00665OOOO NCT
C - Lock Type - ST CL00666OOOO M.R.P.
Description Cat. No. (`)
C - Lock Type - SS CL00667OOOO Per Unit
C - Lock Type - TT CL00668OOOO External Neutral CT for UW-MTX Releases

Locking arrangement for OFF button Frame-1, 2 & 3 400-800A CL00717OOOO


CL90814OOOO
with C - Lock (on breaker) Frame-1, 2 & 3 1000-1600A CL00718OOOO

Locking arrangement for ISO position Frame-1 2000-2500A CL00719OOOO


CL90982OOOO
for C - Lock (on Cradle) Frame-2 & 3 2000-3200A
CL00720OOOO
Locking arrangement for ANY position Frame-3 4000A
CL90981OOOO
with C - Lock (on Cradle) Frame-3 5000-6300A CL00721OOOO

Note: For Mechanical Interlock using Key & Lock please order combination * Available on request
of Lock and Locking arrangement.

L&T, ESP 01.01.2015 53


Accessories of Air Circuit Breakers

Draw-out ACBs Terminal Adaptors Fix ACBs Terminal Adaptors

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Terminal Adaptors for Draw-out Omega ACBs Terminal Adaptors for Fixed Omega ACBs

Frame-1 400-2000A (Vertical / Horizontal) CL60963OOOO Frame-1 400-1600A N/S (Vertical / Horizontal) CL60967OOOO

Frame-1 2500A (Vertical) Frame-1 400-2000A H & 2000A S


CL60964OOOO CL60968OOOO
Frame-2 400-3200A (Vertical / Horizontal) (Vertical/Horizontal)

Frame-3 400-4000A (Vertical / Horizontal) # CL90747OOOO Frame-1 2500A S/H (Vertical) CL60976OOOO

Frame-3 5000A (Vertical) # CL90748OOOO Frame-2 400-3200A S/H (Vertical / Horizontal) CL60977OOOO

Frame-3 6300A (Vertical) # CL60965OOOO Frame-3 400-4000A H/V (Vertical / Horizontal) # CL90668OOOO

Frame-3 5000A H/V (Vertical) # CL60982OOOO


# : Please consider 4 terminal adaptors per phase (I/C + O/G)
Frame-3 6300A H/V (Vertical) # CL90669OOOO

# : Please consider 4 terminal adaptors per phase (I/C + O/G)

Mechanical Interlock using Bowden Cable MODBUS Module Power Metering Module

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Mechanical Interlock using Bowden Cable (5 meters length) MATRIX Releases & Modules
Between 2 Incomers CL90663OOOO UW-MTX1.0 CL91966OOOO

Between 3 Incomers CL90664OOOO UW-MTX1G CL91971OOOO

Between 2 Incomers & 1 Standby CL90665OOOO UW-MTX1.5G CL91965OOOO

Between 2 Incomers & 1 Buscoupler CL90666OOOO UW-MTX2.5 CL90112OOOO


Mechanical Interlock using Bowden Cable (3 meters length) UW-MTX2.5G CL90610OOOO

Between 2 Incomers CL90659OOOO UW-MTX3.5 CL90113OOOO

Between 3 Incomers CL90660OOOO UW-MTX3.5EC CL90700OOOO

Between 2 Incomers & 1 Standby CL90661OOOO UW-MTX4.5 CL90611OOOO

Between 2 Incomers & 1 Buscoupler CL90662OOOO Power supply module (UW-PS) CL90722OOOO

Mechanical Interlock using Bowden Cable (2 meters length) Relay Module CL90716OOOO

Between 2 Incomers CL90810OOOO MODBUS Module CL90709OOOO

Between 3 Incomers CL90811OOOO Profibus Module CL90732OOOO

Between 2 Incomers & 1 Standby CL90812OOOO MATRIX SMART CARD Module CL90705OOOO

Between 2 Incomers & 1 Buscoupler CL90813OOOO Power Metering Module CL90704OOOO

Note: Common from 400A to 6300A and can be interlocked between ZSI Module (UW-ZSI) CL90718OOOO
Fixed / Draw-out / Mixed version
TCS Module (UW-TCS) CL90719OOOO

* Available on request EL Module CL90720OOOO

REF Module CL90721OOOO

Simulation Kit CL90724OOOO

54 L&T, ESP 01.01.2015


C-POWER Air Circuit Breakers
C-POWER S1 Range of Air Circuit Breakers
l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Current rating from 630A to 3200A
l Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
l High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
l High mechanical and electrical operating life
l 100% rated neutral pole
l Common height and depth across the range
l Protection through Thermal - Magnetic (DN1) & Microprocessor releases (SR18, SR18G,
SR18G+D New & SR18Gi+D New )
l Self diagnostic Microprocessor based Releases with on-load testing through TEST button
l Inbuilt thermal memory C-POWER S1 ACB
l Protection Releases conform to EMI/EMC standards
l Breaker control through MODBUS protocol

C-POWER Range of Air Circuit Breakers


l Conforms to IS/IEC 60947-2 & IEC 60947-2
l Current rating from 800A to 6300A
l Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
l High short time fault withstanding capacity, Icu = Ics = Icw for 1 sec for total selectivity
l High mechanical and electrical operating life
l 100% rated neutral pole
l Protection through Thermal - Magnetic (DN1) & Microprocessor releases (SR18, SR18G,
SR18G+D New , SR18Gi+D New & SR71)
l Self diagnostic Microprocessor based Releases with on-load testing through TEST button
l Inbuilt thermal memory
l Protection Releases conform to EMI/EMC standards
C-POWER ACB l Data communication & Power Management
l Breaker control through MODBUS protocol

C-POWER ACBs for DG application New

l G Range Air Circuit Breakers for DG protection


l 400A to 2000A in 3P fix version
l Choice of Thermo-Magnetic release-DN1 / Micro processor based release SR18G (LSIG)
l lcu=lcs=lcw=50kA for 1 second across the entire range
l Compact and rugged design with inbuilt Under-voltage protection

C-POWER ACBs for Harsh Environment New


C-POWER G Range

l Please contact the nearest branch office for Details & product Selection

Breaking Capacities Offered:


Icu = Ics = Icw for 1 sec

630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
New
CN-CS : E / G 50kA 50kA 50kA 50kA 50kA 50kA

Frame-1

CN-CS : S1 50kA 50kA 50kA 50kA 50kA 50kA 60kA 60kA

Frame-1 Frame-2

CN-CS : C 50kA 50kA 50kA 50kA 55kA 60kA 70kA 95kA 95kA

CN-CS : H 65kA 65kA 65kA 65kA 75kA 75kA


New
CN-CS : H2 75kA 75kA

CN-CS : H / H1 100kA 100kA

Frame-1 Frame-2 Frame-3 Frame-4

For technical & dimension details please refer product catalogue. 400A ACB also available on request.

L&T, ESP 01.01.2015 55


C-POWER Air Circuit Breakers

C-POWER S1 3 & 4 Pole Draw-out ACBs


Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw M.R.P. M.R.P. M.R.P. M.R.P.
(1 sec) Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
MDO SL96041 144580 SL96061 181630 SL95331 130580 SL95351 167630
630A 50kA
EDO SL96051 178580 SL96071 215630 SL95341 164580 SL95361 201630
MDO SL96042 144580 SL96062 181630 SL95332 130580 SL95352 167630
800A 50kA
EDO SL96052 178580 SL96072 215630 SL95342 164580 SL95362 201630
MDO SL96043 151900 SL96063 191960 SL95333 137900 SL95353 177960
1000A 50kA
EDO SL96053 185900 SL96073 225960 SL95343 171900 SL95363 211960
MDO SL96044 169860 SL96064 213610 SL95334 155860 SL95354 199610
1250A 50kA
EDO SL96054 203860 SL96074 247610 SL95344 189860 SL95364 233610
MDO SL96045 191680 SL96065 234940 SL95335 177680 SL95355 220940
1600A 50kA
EDO SL96055 225680 SL96075 268940 SL95345 211680 SL95365 254940
MDO SL96046 228140 SL96066 286150 SL95336 214140 SL95356 272150
2000A 50kA
EDO SL96056 262140 SL96076 320150 SL95346 248140 SL95366 306150

C-POWER S1 3 & 4 Pole Fixed ACBs


Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw M.R.P. M.R.P. M.R.P. M.R.P.
(1 sec) Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
MF SL95561 99720 SL95581 124660 SL95481 85720 SL95501 110660
630A 50kA
EF SL95571 133720 SL95591 158660 SL95491 119720 SL95511 144660
MF SL95562 99720 SL95582 124660 SL95482 85720 SL95502 110660
800A 50kA
EF SL95572 133720 SL95592 158660 SL95492 119720 SL95512 144660
MF SL95563 103950 SL95583 129930 SL95483 89950 SL95503 115930
1000A 50kA
EF SL95573 137950 SL95593 163930 SL95493 123950 SL95513 149930
MF SL95564 125390 SL95584 156750 SL95484 111390 SL95504 142750
1250A 50kA
EF SL95574 159390 SL95594 190750 SL95494 145390 SL95514 176750
MF SL95565 137790 SL95585 172250 SL95485 123790 SL95505 158250
1600A 50kA
EF SL95575 171790 SL95595 206250 SL95495 157790 SL95515 192250

M.R.P. changes for product customization w.r.t. SR18G ACB M.R.P. M.R.P. (`) Per Unit
Bus - Coupler (w/o protection) Reduce 23000
Microprocessor based SR18 (LSI) Reduce 3000
New Microprocessor based SR18G+D (LSING + Current Metering) Add 4500
New Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 6000

C-POWER S1 Draw-Out ACBs will have inbuilt - 2NO+2NC Aux contact for MDO & 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly,
Racking handle, Door sealing frame, Push-button cover & Rating error preventor.
C-POWER S1 Fixed ACBs will have inbuilt - 2NO+2NC Aux contact for MF & 6NO+6NC Aux contact for EF breakers, Door sealing frame & Push-button cover.
Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.

G Range 3 Pole Manual Fixed for


CN-CSE Range 3 Pole Manual Fixed DG Application
(with in-built UV Protection & 2NO + 2NC Aux Contact Block)
Thermal-Magnetic Release Type DN1 Thermal-Magnetic Release Type DN1 Microprocessor Based SR18G
Breaking
Capacity
Rating Version M.R.P. M.R.P. M.R.P.
Icu=Ics=Icw Cat. No. (`) Cat. No. (`) Cat. No. (`)
(1 sec)
Per Unit Per Unit Per Unit
400A 50kA 3P MF SL95721OOOO 60340 SL91263OOOO 74600 SL91320OOOO 88600
630A 50kA 3P MF SL95722OOOO 60870 SL91264OOOO 74750 SL91321OOOO 88750
800A 50kA 3P MF SL95723OOOO 62650 SL91265OOOO 75200 SL91322OOOO 89200
1000A 50kA 3P MF SL95724OOOO 64860 SL91266OOOO 78300 SL91323OOOO 92300
1250A 50kA 3P MF SL95725OOOO 84170 SL91267OOOO 98100 SL91324OOOO 112100
1600A 50kA 3P MF SL95726OOOO 93750 SL91268OOOO 108800 SL91325OOOO 122800
2000A 50kA 3P MF SL93297OOOO 106550 SL91269OOOO 128300 SL91326OOOO 142300

56 L&T, ESP 01.01.2015


C-POWER Air Circuit Breakers

C-POWER 3 & 4 Pole Draw-out ACBs


Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw M.R.P. M.R.P. M.R.P. M.R.P.
(1 sec) Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
MDO SL95311 189010 # 241220 # 175010 # 227220
800A 65kA
EDO SL95321 223010 # 275220 # 209010 # 261220
MDO SL95312 204270 # 256110 # 190270 # 242110
1000A 65kA
EDO SL95322 238270 # 290110 # 224270 # 276110
MDO SL95313 230820 # 280510 # 216820 # 266510
1250A 65kA
EDO SL95323 264820 # 314510 # 250820 # 300510
MDO SL95314 251020 # 314180 # 237020 # 300180
1600A 65kA
EDO SL95324 285020 # 348180 # 271020 # 334180
MDO ST35545 261570 ST35565 319710 SL93065 247570 ST25035 305710
2000A 55kA
EDO ST35555 295570 ST35575 353710 SL93085 281570 ST25045 339710
MDO ST35546 286890 ST35566 349700 SL93066 272890 ST25036 335700
2500A 60kA
EDO ST35556 320890 ST35576 383700 SL93086 306890 ST25046 369700
MDO (H2) New
SL94822 356240 SL94826 436810 SL94814 342240 SL94818 422810
3200A 75kA
EDO (H2) New SL94824 390240 SL94828 SL94816 376240 SL94820 456810
470810
MDO (H2) New SL94823 SL94827 SL94815 SL94819
4000A 75kA * * * *
EDO (H2) New SL94825 * SL94829 SL94817 SL94821
* * *
5000A 95kA MDO/EDO # * # # # *
* *
6300A 95kA MDO/EDO # * # # # *
* *
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office

C-POWER 3 & 4 Pole Manual Fixed ACBs


Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw M.R.P. M.R.P. M.R.P. M.R.P.
(1 sec) Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A 50kA
1000A 50kA
1250A 50kA * *
1600A 50kA
MF
2000A 55kA SL97635 165230 # 214330 SL93005 151230 # 200330
2500A 60kA SL97636 182070 # 245450 SL93006 168070 # 231450
3200A 70kA # * # * # * # *
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office

M.R.P. changes for M.R.P.


product customization w.r.t. SR18G M.R.P. (`)
Per Unit
Bus-Coupler (w/o protection) Reduce 23000
Microprocessor based SR18 (LSI) Reduce 3000
New Microprocessor based SR18G+D (LSING + Current Metering) Add 4500
New Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 6000
Microprocessor based SR71 (LSING + Current metering + Advance protection + PS Module) Add
Communication Module (MODBUS) for SR71 release (SR71 - COM) SL94698
*
Power Metering Module for SR71 release (SR71 - PM) SL94699

C-POWER Draw-Out ACBs will have inbuilt - 6NO+6NC Aux contact, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating
Error preventor. Option of horizontal & vertical termination upto 4000A also available. Operation counter for 4000A & above.
EDO version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
C-POWER Fixed ACBs will have inbuilt - 6NO+6NC Aux contact, Door sealing frame & Push-button cover. Operation counter for 4000A & above.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
Note: Electrical Fixed type breakers are available on request.
# Available on "Made to order" basis. * Available on request

L&T, ESP 01.01.2015 57


Accessories of C-POWER Air Circuit Breakers
Accessories (Common for C-POWER Family)

AN1 Module LTPB LIP Shunt Release UV Release

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Lockable Trip Push Button (LTPB) Shunt Release (SR)

Type AA SL93148OOOA 2460 Type EA : 24/48V DC SL92718O4OO 2460

Type BB SL93148OOOB 2460 Type EA : 110V DC SL92718O1OO 2460

Type CC SL93148OOOC 2460 Type EA : 220V DC SL92718O2OO 2460

Type DD SL93148OOOD 2460 Type EA1 : 110V AC SL92718OAOO 2460

Lockable Trip Push Button kit (3 I/C & 2 B/C) SL91936OOOO 12340 Type EA1 : 240V AC SL92718OBOO 2460

Lockable Trip Push Button kit (A to Z) ST28895OOOO 64100 Type EA1 : 415V AC SL92718ODOO 2460

Lockable Trip Push Button kit (A to P) ST28730OOOO 39450 Under Voltage Release (UVR)

Locking of ACB in Isolated position (LIP) Type MV : 24V DC ST36877OOOO 3620

Type A SL93146OOOA 2460 Type MV : 240V AC SL92720BOOO 3620

Type B SL93146OOOB 2460 Type MV : 415V AC SL92720DOOO 3620

Type C SL93146OOOC 2460 Earth Fault Release ( for DN1)

Type D SL93146OOOD 2460 Type EF1 (10%, 20% In ) SL91340OOOO 2460

Locking of ACB in Any position (LAP) Type EF2 (30%, 40%, 50% In) SL91341OOOO 2460

Type A SL93147OOOA 2460


Type B SL93147OOOB 2460 AN1 Remote Annunciation Module for SR18/
SL94654OOOO 7680
Type C SL93147OOOC 2460 SR18G/SR18G+D/SR18Gi+D/SR21i : 240V AC
Type D SL93147OOOD 2460 Microswitch for Voltmetric Releases (2) each 1990
SL92703OOOO
Racking Interlock
Microswitch for Common Indication of O/L &
SL92704OOOO 1990
Type AA SL93149OOOA 4630 S/C (3) each
Type BB SL93149OOOB 4630 Microswitch for Separate Indication of O/L &
SL92705OOOO 3330
Type CC SL93149OOOC 4630 S/C (3) each (for DN1 release)
Type DD SL93149OOOD 4630 Service Position Microswitch - Right (2) SL93142OOOO 1340

Door Interlock SL93150OOOO Service Position Microswitch - Left (2) SL93143OOOO 1340
2460
Test or Isolated Position Microswitch - Right (2) SL93144OOOO 1340
Test or Isolated Position Microswitch - Left (2) SL93145OOOO 1340

Note :
a. The Numerical in brackets, against various accessories indicate the SICs
required for wiring purpose in Draw-Out breakers
b. Shunt release requires one set of auxiliary contacts
c. Maximum 24 SICs can be fitted on an ACB. In Electrical ACBs 5 SICs are
Vertical Terminal Adaptor
prewired for control circuit purpose
M.R.P.
Description & Rating Cat. No. Qty (`)
Per Unit
Vertical Terminal Adaptors for Draw out C-POWER ACB Features
630-1250 S1/800-1000 C SL93281OOOO 1 3220 l Remote Status & Control of ACB
l Communicates on MODBUS Protocol
1600-2000 S1/1250-1600 C SL93282OOOO 1 3770
l Inbuilt RS485 Port
2000 C SL93284OOOO 1 5160
UN-CO module
2500 C SL93285OOOO 1 5600
M.R.P.
2500 S1 SL93289OOOO 1 5600 Description Cat. No. Qty (`)
Per Unit
3200 S1 SL93286OOOO 1 6200
UN-CO module for Breaker control CL90852OOOO 1 9000
3200H2/H1, 4000H2/H SL93288OOOO 1 15040

58 L&T, ESP 01.01.2015


Spares of C-POWER Air Circuit Breakers
Protection Releases

M.R.P.
Description Cat. No. (`)
Per Unit

Protection Releases

Microprocessor based type SR71 On Request

New Microprocessor based type SR18Gi+D SL94813OOOO 36000

New Microprocessor based type SR18G+D SL94812OOOO 34500


Microprocessor based type SR18G SL93959OOOO 30000
SR71 Microprocessor based type SR18 SL93958OOOO 27000
Thermal-Magnetic Release type DN1 SL93152OOOO 16000
New New Test-Kit SRT-2 (SR21i/SR18G/SR18) ST23130OOOO 31300

Test-Kit SRT (SR18G + D/SR18Gi+D) CL90853OOOO 24860

SR18G+D SR18Gi+D Upgrade to high end


communicable Release SR71
Retrofit kit solutions are available
For further details please contact
the nearest branch office

SR18G SR18

DN1 Test Kit

M.R.P.
Description Cat. No. Qty. (`)
Per Unit
CTs for SR18 / SR18G / SR18G+D / SR18Gi+D
630 S1 Fix & Draw-out ST37495OOOO 1 4120
800 C/H/S1 Fix & Draw-out SL01857OOOO 1 4120
1000 C/H/S1 Fix & Draw-out SL01858OOOO 1 4120

For retrofitting of 1250 C/H/S1 Fix & Draw-out SL90571OOOO 1 5000

any ACB to 1600 C/H/S1 Fix & Draw-out SL90572OOOO 1 5000


2000 C/H Fix & Draw-out SL90565OOOO 1 5360
2000 S1 Draw-out SL93210OOOO 1 5360

Please contact the nearest 2500 C/H Fix & Draw-out


SL90566OOOO 1 5360
branch office 2500 S1 Draw-out
3200 D Fix & Draw-out SL90567OOOO 1 6480
3200 S1 Draw-out SL90575OOOO 1 6480
3200 H2/H1 SL01740OOOO 1 6480
4000 C SL90568OOOO 1 7330
4000 H2/H SL01739OOOO 1 7330

For External Neutral C.T.s please use the above Cat. No.

L&T, ESP 01.01.2015 59


N e w

Presenting Ti the new, design-verified aluminium busbar-based


power distribution solution from L&T.

The new Ti range of panels is a power distribution solution from Moreover, these systems feature a fully-compartmentalized design,
L&T, available with an Aluminum busbar option. Ti is a design with an option of aluminium or copper busbars ensuring quicker
verified solution complying with latest IEC-61439 standard and delivery and easier installation.
available up to 4000A rating. It offers unique blend of quality,
So, the next time you require electrical distribution solutions for
safety and standardization. Ti offering through L&Ts authorized
your project, get the aluminium edge with the design-verified
franchisee network further gives edge as cost competitiveness and
Ti Range.
localized support for all future needs.
The unique busbar arrangement reduces impedance and heat loss,
thereby saving almost 40% energy over conventional systems.
Reactive Power Management Solutions
Power Factor Correction Capacitors
Standard Duty Capacitors LTXL - Ultra Heavy Duty Capacitors

l MPP standard duty capacitors l Advanced APP technology


l Operating losses - 0.45 W / kVAr l Lower operating losses - 0.35 W / kVAr
l Over current withstand capability l High over current withstand capability
- 1.5 times rated current - 3 times rated current
l Inrush current withstand capability l High inrush current withstand capability
- 200 times rated current - 500 times rated current
l Number of switching l Higher operating life - 300000 hours
- 5000 operations per year l More number of switching
- 20000 operations per year

M.R.P. M.R.P.
kVAr Voltage kVAr Voltage
Duty Type (`) Duty Type (`)
Rating (V) Rating (V)
per kVAr per kVAr

Cylindrical 440 V 652


1 to 6 kVAr - Series : LTCCF 1 to 25 440 V 186 480 V 717
7.5 to 25 kVAr - Series : LTCCD 5 to 15
Standard Box 525 V 782
Duty Box (Oil filled)
LTXL - Ultra 690 V 815
1 to 6 kVAr - Series : LTBCF 1 to 30 440 V 254 Heavy Duty
7.5 to 50 kVAr - Series : LTBCD 5 to 100 kVAr 440 V 640
Series : LTBCU 480 V 704
20 to 100
525 V 768
690 V 800
Heavy Duty Capacitors Prices of 850 V and 1000 V LTXL capacitors are available on request

Ordering Information for Capacitors

C - Cylindrical, B - Box

l MPP heavy duty capacitors


l Operating losses - 0.35 W / kVAr Duty : D/F - Standard**,
l Over current withstand capability H - Heavy, N - Heavy Duty
- 1.8 times rated current Gas Filled, U - Ultra Heavy
l Inrush current withstand capability
- 300 times rated current Sample ratings
l Operating life - 150000 hours 01 - 1 kVAr
l Number of switching 07 - 7.5 kVAr
kVAr
- 8000 operations per year Rating 10 - 10 kVAr
M.R.P. 12 - 12.5 kVAr
kVAr Voltage
Duty Type (`)
Rating (V) 00 - 100 kVAr
per kVAr
440 V 331 Voltages : A - 415V, B - 440V,
480 V 364 C - 480V, M - 525V,
3 to 15
525 V 397 W - 690V,
Cylindrical
(Gas filled) 690 V 413 Y - 850V, Z - 1000V
20 & 25 440 V 323
3 to 30 kVAr
Series : LTCCN 480 V 355 Cat. L T C 3 2
20 to 30 525 V 388 Nos.
690 V 404
Heavy Duty
440 V 406 ** F - 1 to 6 kVAr. D - 7.5 kVAr & above
Box 5 to 15 480 V 447
(Resin filled) 525 V Standard Rating Available are :
487
1, 2, 3, 4, 5, 6, 7.5, 8.33, 10, 12.5, 15, 20, 25, 30, 50, 100
5 to 50 kVAr 440 V 397
Series : LTBCH 20 to 50 480 V 437
525 V 476

L&T, ESP 01.01.2015 61


Reactive Power Management Solutions
7% Detuned Reactors, 440 V 50 Hz Capacitor Duty Contactors - Type MO C

MO C25 MO C50 MO C80


kVAr Rating Built-in M.R.P. Std.
@ 415V, Type Auxiliary Cat. No. (`) Pkg.
3Ph, 50Hz Contacts Per Unit (Nos.)
1NO CS96320 1790 1
l Copper & Aluminium wound reactors 8.5 MO C8.5
1NC CS96337 1790 1
l Lower operating losses
1NO CS96321 2035 1
l High linearity - 1.8 times the rated current 12.5 MO C12.5
1NC CS96338 2035 1
l Thermal cut off
1NO CS90019 2870 1
New 15 MO C15
Aluminium Reactor Copper Reactor 1NC CS90020 2870 1

kVAr M.R.P. M.R.P. 1NO CS90021 3280 1


Cat. No. (`) Cat. No. (`) 20 MO C20
Rating 1NC CS90022 3280 1
Per Unit Per Unit
5 LTAL0705B2 7000 LTFR0705B2 7390 1NO CS96322 3720 1
25 MO C25
10 LTAL0710B2 9800 LTFR0710B2 11615 1NC CS96339 3720 1
12.5 LTAL0712B2 10750 LTFR0712B2 12875 1NO CS96323 6880 1
15 LTAL0715B2 11500 LTFR0715B2 14255 33.5 MO C33.5
1NC CS96340 6880 1
20 LTAL0720B2 13700 LTFR0720B2 16890
1NO CS96324 10140 1
25 LTAL0725B2 14500 LTFR0725B2 17950 50 MO C50
50 LTAL0750B2 23000 LTFR0750B2 28505 1NC CS96341 10140 1
75 LTAL0775B2 34200 LTFR0775B2 42230 1NO CS96325 12300 1
70 MO C70
100 LTAL0700B2 47000 LTFR0700B2 58065 1NC CS96342 12300 1
Note: Prices of 5.67% & 14% reactors are available on request 1NO CS96326 13450 1
80 MO C80
1NC CS96343 13450 1
Please refer page No. 7 for further details.

Selection of capacitors for detuned Thyristor Switching Module, 440V 50Hz


harmonic filter application l High Peak Inverse Voltage (PIV) - 2.2 kV
Capacitor kVAr selection is done considering the tuning frequency of 189 Hz with l Lower operating losses
7% reactor and based on standard ratings available. l Auto thermal cut off

Effective With 7% detuned reactor M.R.P.


kVAr kVAr Rating Cat. No. (`)
output Reactor (440 V) Capacitor (480 V) Capacitor (525 V) Per Unit
10 LTTSM10B2 19760
5 kVAr 5 kVAr 7.5 kVAr 480 V 7.5 kVAr 525 V 25 LTTSM25B2 28190
50 LTTSM50B2 32900
10 kVAr 10 kVAr 12.5 kVAr 480 V 12.5 kVAr 525 V

12.5 kVAr 12.5 kVAr 15 kVAr 480 V 15 kVAr 525 V APFC Relays
15 kVAr 15 kVAr 20 kVAr 480 V 20 kVAr 525 V etaCON L series with
Auto-set function
20 kVAr 20 kVAr 25 kVAr 480 V 25 kVAr 525 V M.R.P.
Steps CT Voltage
25 kVAr 525 V + Model Description Description secondary input Cat. No. (`)
25 kVAr 25 kVAr 30 kVAr 480 V 8.33kVAr 525 V Per Unit

2 nos of (25 kVAr 525 V + etaCON L3 3 stage 3 ERPML03D500 9000


50 kVAr 50 kVAr 2 nos of 30 kVAr 480 V
8.33kVAr 525 V) etaCON L5 5 stage 4 +1* ERPML05D500 10000
3 nos of (25 kVAr 525 V +
75 kVAr 75 kVAr 3 nos of 30 kVAr 480 V etaCON L7 7 stage 6 + 1* 5 Amp 415V ERPML07D500 11000
8.33kVAr 525 V)
4 nos of (25 kVAr 525 V + etaCON L8 8 stage 7 + 1* ERPML08D500 13600
100 kVAr 100 kVAr 4 nos of 30 kVAr 480 V
8.33kVAr 525 V)
etaCON L12 12 stage 11 + 1* ERPML12D500 14800
Selection for 5.67% and 14% reactors available on request. * Last Contact can be programmed for capacitor switching / Alarm function /
Fan Control

Sample Selection: for 25kVAr 7% detuned reactors with


heavy duty capacitors, place an order for: 1 No. 25 kVAr 7% detuned reactor:
LTFR0725B2 & 1 No. 30 kVAr LTCCN capacitors at 480 V: LTCCN330C2

M.R.P.
Description CT Voltage
Model secondary input Cat. No. (`)
Per Unit
Fourteen Stage 1 A or 5 A -
RPM 14 Field 240V MRPM1400000 16900
APFC Relay selectable

62 L&T, ESP 01.01.2015


Reactive Power Management Solutions
etaSYS Standard APFC Panels

Branch Harmonic
Product Description kVAr ratings Capacitors Main Incomer Protection Switching filter

Contactor switched Heavy Duty Gas MCCB - up to 350 kVAr; MO C Capacitor


etaSYS MH1 35 to 500 kVAr filled capacitors MCCB duty contactor
standard APFC Panels ACB 400 to 500 kVAr

Contactor switched Heavy Duty Gas MCCB - up to 350 kVAr; MO C Capacitor 7% copper
etaSYS MH2 standard APFC Panels 100 to 500 kVAr filled capacitors MCCB
ACB 400 to 500 kVAr duty contactor reactor
with harmonic filters

Contactor switched Heavy Duty Gas MCCB - up to 350 kVAr; MO C Capacitor


etaSYS - FH1 35 to 500 kVAr filled capacitors HRC Fuse
standard APFC Panels ACB 400 to 500 kVAr duty contactor

Contactor switched Heavy Duty Gas MCCB - up to 350 kVAr; MO C Capacitor 7% copper
etaSYS - FH2 standard APFC Panels 100 to 500 kVAr filled capacitors HRC Fuse
ACB 400 to 500 kVAr duty contactor reactor
with harmonic filters

etaSYS - Thyristor switched Heavy Duty Gas MCCB - up to 350 kVAr; Semiconductor Thyristor 7% copper
FH3 (RTPFC) standard APFC Panels 100 to 500 kVAr filled capacitors ACB 400 to 500 kVAr fuse switching modules reactor
with harmonic filters

Contactor switched LTXL - Ultra Heavy MCCB - up to 350 kVAr; MO C Capacitor


etaSYS - MU1 100 to 500 kVAr Duty capacitors MCCB
standard APFC Panels ACB 400 to 500 kVAr duty contactor

Contactor switched LTXL - Ultra Heavy MCCB - up to 350 kVAr; MO C Capacitor 7% copper
etaSYS MU2 standard APFC Panels 100 to 500 kVAr Duty capacitors MCCB
ACB 400 to 500 kVAr duty contactor reactor
with harmonic filters

Contactor switched LTXL - Ultra Heavy MCCB - up to 350 kVAr; MO C Capacitor


etaSYS - FU1 35 to 500 kVAr Duty capacitors HRC Fuse
standard APFC Panels ACB 400 to 500 kVAr duty contactor

Contactor switched LTXL - Ultra Heavy MCCB - up to 350 kVAr; MO C Capacitor 7% copper
etaSYS - FU2 standard APFC Panels 100 to 500 kVAr Duty capacitors HRC Fuse
ACB 400 to 500 kVAr duty contactor reactor
with harmonic filters

etaSYS - Thyristor switched LTXL - Ultra Heavy MCCB - up to 350 kVAr; Semiconductor Thyristor 7% copper
FU3 (RTPFC) standard APFC Panels 100 to 500 kVAr Duty capacitors ACB 400 to 500 kVAr fuse switching modules reactor
with harmonic filters

Note:
1) Prices of all the above panels are available on request
2) Lead time of standard APFC panels is 6 to 8 weeks (Ex-Nagpur)
3) Freight charges at actuals
4) For other ratings and specifications, contact nearest branch office

Features Benefits
l Wide range of ratings (35 to 500 kVAr) covers the typical requirement of APFC panel ratings l Faster completion of pre-manufacturing
for most of the industries procedures due to readily available prices,
l All the panels are with optimal number of steps and step sizes BoM and GA drawings
- Offers sufficient step resolution which would be suitable for all types of industries l Faster execution of the panel work due to
standardised manufacturing process and
- Panel operation without hunting of capacitors
standard set of BoM
l Pre-selected switchgear with accurate ratings offers reliable operation, protection and isolation
l Better quality and reliability of factory build
l Accurate combination of capacitor and reactor offers better protection against harmonics APFC panels
l IP 42 panels
l Standard GA drawing readily available
l Auto and manual switching options
l Hunt free and reliable switching sequence

L&T, ESP 01.01.2015 63


Digital Protective Relays
3 Phase Over Current + Earth Fault Relay Single Pole Over Current or
C.T. Rating 1A or 5A, Field Selectable Earth Fault Relay
Newries C.T. Rating 1A or 5A, Not Field Selectable
e
nX S

IDMT & Definite time characteristics IDMT and Definite time characteristics
Last 30 trip data recording with
date and time
Password Protection

Aux. M.R.P.
Supply Output Device
Model Code Cat. No. (`)
(V) Contacts Aux. C.T. M.R.P.
Per Unit Supply Secondary Device (`)
Model Code Cat. No.
24 - 240V 2 NO + 2 NC MC31ANX2200 (V) (A) Per Unit
MC31AnX 51, 51N 16000
AC/ DC 4 NO MC31ANX4000 1A MC12AA10X00
20 - 110V AC/DC
5A 50, 51 MC12AA50X00
MC12 or 9600
1A 50N, 51N MC12AB10X00
88 - 264V AC/DC
5A MC12AB50X00
3 Phase Over Current + Earth Fault Relay
with High Set
C.T. Rating 1A or 5A, Field Selectable

Newries
e
nX S
IDMT & Definite time characteristics
Last 30 trip data recording with MC12 MC12 MC12 MC12

date and time Earth Fault Back up Earth Earth Fault Single Phase Over Current
Protection Fault Protection Protection Protection - 50, 51
Password Protection 50N, 51N 50N, 51N

Aux. M.R.P.
Supply Output Device
Model Code Cat. No. (`)
(V) Contacts
Per Unit
24 - 240V 2 NO + 2 NC 51, 51N, MC61ANX2200 Instantaneous Earth Fault Relay
MC61AnX 18000
AC/ DC 4 NO 50, 50N MC61ANX4000 C.T. Rating 1A or 5A, Not Field Selectable

High Impedance relay.


3 Phase Over Current + Earth Fault Relay Meant for Restricted Earth fault protection of
with High Set & RS - 485 Port Transformers/Generators or Differential
Protection of Generators.
C.T. Rating 1A or 5A, Field Selectable

Newries
e
nX S C.T. M.R.P.
IDMT & Definite time characteristics Model Secondary Range Device
Cat. No. (`)
Code
Last 30 trip data recording with (A) Per Unit
date and time 10 - 40 % MC14SX10100
1
Password Protection 20 - 80 % 87 / 87N / MC14SX10200
SC14S 8400
10 - 40 % 64REF MC14SX50100
5
Aux. 20 - 80 % MC14SX50200
Output M.R.P.
Supply Device
Model Code Cat. No. (`)
(V) Contacts
Per Unit
24 - 240V 51, 51N, G
MC61CnX 4 NO MC61CNX4000 24000
AC/ DC 50, 50N
Rs Rs
SC14S SC14S SC14S
SC14S SC14S

Reverse Power Relay Rs Rs Rs

C.T. Rating 1A or 5A, Not Field Selectable


Differential Protection Restricted Earth Fault Protection

Aux C.T. M.R.P.


Supply Secondary Device (`)
Model Code Cat. No.
(V) (A) Per Unit
1A MRP11A10X00
20 - 110V AC/DC
5A MRP11A50X00
MRP11 32 21500
1A MRP11B10X00
88 - 264V AC/DC
5A MRP11B50X00

L&T, ESP 01.01.2015 65


Digital Protective Relays
Mini Motor Protection Relay Compact Motor Protection Relay - MM10
Protections: Flush Mounting with display
- Thermal Overload Last trip data recording
- Earth Fault
- Locked Rotor
Protections:
- Single Phasing, Current Unbalance, New
- Thermal Overload with pre- alarm
Phase Sequence Reversal
- Under Current - Short Circuit
- Earth fault
Inbuilt CTs (1 A to 88 A) - Phase loss, Unbalance, Phase reversal
Trip indication - Under Current
Test facility - Prolong starting, Locked Rotor
Selectable trip class - 10A, 10, 20 and 30 as per IEC 947-4-1

Thermal M.R.P. Aux. M.R.P.


Aux. Device CT Device
Model O/L Range Cat. No. (`) Model Supply secondary Cat. No. (`)
supply Code code
(A) Per Unit Per Unit
1 - 2.75 MPR300BE010 37, 46, 49,
110 - 240 V 5 Amp
2 - 5.5 MM10 50 / 51, MM10240X005 26000
MPR301BE020 AC / DC
51LR, 64
4 - 11 MPR302BE040
240V AC
8 - 22 MPR303BE080
16 - 44 MPR304BE160
32 - 88 49, 51LR, MPR305BE320
MPR300 5700
1 - 2.75 51N, 37, 46, MPR300BB010
2 - 5.5 MPR301BB020
Comprehensive Motor protection relay
4 - 11 MPR302BB040
8 - 22 MPR303BB080 MM30-743
110V AC
16 - 44 MPR304BB160 with current based protections
32 - 88 MPR305BB320

Application Diagram
M.R.P.
R R
Model Aux. Supply Device Cat. No. (`)
Y Y
B B code Per Unit
Fuse
Fuse In case of reversible starters;
MPR300 must be placed before
20 - 110V AC/ DC 37,46,47,48, EMM30AXX00E
the reversing contactors. MM30 - 743 49,50/51,51LR, 69800
MPR300 must sense Line Current 88 - 240V AC/ DC 64, 66,68,74 EMM30BXX00E
in case of Star Delta Starter

Forward Reverse
Contactor Contactor
Line Delta Star
Contactor Contactor Contactor
Comprehensive Motor protection relay
3 MM30-W74*
Motor

3
with current and voltage based protections
Motor

MPR300 - Trip Time Characteristics

Trip Trip time delay M.R.P.


Model Aux. Supply Device Cat. No. (`)
class I = 120% of Im I = 150% of Im I = 720% of Im code Per Unit
10A > 2 hours 2 min 2 - 10 secs
10 > 2 hours 4 min 4 - 10 secs 20 -110V AC/DC 12/14,27/59,37, EMM30WAX002
MM30 - W74 46,47,48,49, 86500
20 > 2 hours 6 min 6 - 20 secs
50/51, 51LR,55,
30 > 2 hours 12 min 9 - 30 secs 88 -240V AC/DC EMM30WBX002
64,66,68,74,81.

Im - Motor Full Load Current * available on request only


I - Actual current drawn by the Motor

66 L&T, ESP 01.01.2015


Digital Protective Relays
MCOMP - Intelligent Motor Control, Monitoring and Protection Relay

Current & Voltage based metering and protection in a single compact unit
In-built voltage module: enables power measurement
plete 6 DI & 4 DO in base unit
Com tion
solu Universal auxiliary supply
for C Communication capability: Modbus RTU, Modbus TCP / IP, Profibus
a rt MC
Sm Inbuilt Analog output & RTD / PTC inputs
OLED Display: 170 viewing angle, brighter pixilation
Conformal coating

MCOMP Relay Selection Guide

i. Modbus RTU

Main unit Communication Protocol ii. Modbus TCP / IP

iii. Profibus

i. 240 V AC / DC

Digital Input Rating ii. 110 V AC / DC

iii. 24 VDC

i. RTD
Temperature Sensor
ii. PTC

i. 80 - 240 V AC / DC
Aux. supply
ii. 24 V DC

i. 0.5 Meter
CT Unit Cable length
ii. 1.0 Meter

i. 0.6A to 2.0A

MCOMP Relay ii. 1.8A to 5.4A

Current Rating iii. 4.5A to 13.5A

iv. 12.6A to 37.8A

v. 36A to 81A

i. 0.5 Meter
Display unit
Cable length ii. 1.0 Meter

iii. 2.0 Meter

i. 80 - 240 V AC / DC
Aux. Supply
ii. 24 VDC

i. 8 DI
Expansion Module Configuration type
ii. 4 DI + 2 DO

i. 220 V AC / DC

Digital Input Rating ii. 110 V AC / DC

iii. 24 VDC

L&T, ESP 01.01.2015 67


Digital Protective Relays
APFC Relays Single Phase Under Voltage or
etaCON L series with Auto-set function Over Voltage Relay

Compact size (96 x 96 mm)


for etaCON L3, L5, L7
Standard size (144 x144 mm)
for etaCON L8, L12

M.R.P. Aux. M.R.P.


Steps CT Voltage Supply Device
Model Description Description secondary input Cat. No. (`) Model Cat. No. (`)
(V) code
Per Unit Per Unit
20 - 110V AC/DC MV12AA00X00
etaCON L3 3 stage 3 ERPML03D500 9000 MV12A 27 or 59 10000
88 - 264V AC/DC MV12AB00X00
etaCON L5 5 stage 4 +1* ERPML05D500 10000
etaCON L7 7 stage 6 + 1* 5 Amp 415V ERPML07D500 11000
etaCON L8 8 stage 7 + 1* ERPML08D500 13600
etaCON L12 12 stage 11 + 1* ERPML12D500 14800

* Last Contact can be programmed for capacitor switching / Alarm function /


Fan Control
Three phase Voltage and Frequency relay
with df/dt and dv/dt protection

M.R.P. M.R.P.
Description CT Voltage Aux. (`)
Model secondary input Cat. No. (`) Model Device code Cat. No.
supply
Per Unit Per Unit

14 Stage 1 A or 5 A - 20 - 110V
RPM 14 Field 240V MRPM1400000 16900 EFD34A00000
APFC Relay AC/ DC
selectable UFD34 27, 59, 81, df/dt, dv/dt 123000
88 - 240V
EFD34B00000
AC/DC

Voltage Frequency and Zero Sequence


Generator protection relay Voltage Relay with Vector shift detection

M.R.P. M.R.P.
Generator Aux. (`) Model Aux. (`)
Model Device code Cat. No. supply Device code Cat. No.
Grounding supply
Per Unit Per Unit

20 - 110 21,24,27/59,32,37, EM30GIAXX00 20 - 110V


VAC/ DC 40,46,49,50/27, EUM30A00000 *
Solid AC/ DC 24, 27d/59d, 47, 59,
MG30I 210000 UM30 123000
grounding 88 - 240 50V/51V, 51BF, 59Uo, 78, 81
EM30GIBXX00 88 - 240V
VAC/DC 60FL, 64S,68,81 EUM30B00000 *
AC/DC

20 - 110 * available on request only


21,24,27/59,32,37, EMG30AXX000
Impedance VAC/ DC 40,46,49,50/27,
MG30 Grounding 50V/51V,51BF, 210000
(NGR/ NGT)
88 - 240 60FL, 64S,68,81
EMG30BXX000
VAC/DC

M.R.P.
Aux. Device (`)
Model Description code Cat. No.
supply
Per Unit

20 - 110V
ED32GAXX000 *
Generator AC/ DC
50/51, 68,
MD32G Differential 266500
87, 87N
Relay
88 - 240V
ED32GBXX000 *
AC/DC

68 L&T, ESP 01.01.2015


Metering Devices
Single Phase kWh meter 3 Phase 4 Wire kWh meter
with LCD display Counter type
Model EM101+ Class 1 Base mounting Model EM301B Class 1 Base mounting

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
1P LCD Meter 5-30A WM101BC5DL0 1420 3Ph 4 W kWh CT op base mtg 240V 5 -10 A WM301BC3C00 3810
1P LCD Meter 5-30A with BOX WM101BC5DL0BOX 1900 3Ph 4 W kWh Dir base mtg 240V 5 -20 A Sleek WM301BC4D20 3410
1P LCD Meter 5-30A with OPTICAL PORT WM101BC5DDH 1950 3Ph 4 W kWh Dir base mtg 240V 10 -40 A Sleek WM301BC6D20 3510
1P LCD Meter 5-30A with Optical port + BOX WM101BC5DDHBOX 2430 3Ph 4 W kWh Dir base mtg 240V 10 - 60 A big body WM301BC7D10 4310
1P LCD Meter 10-60A WM101BC7DL0 1720 3Ph 4 W kWh Dir base mtg 240V 50 -100 A big body WM301BC8D10 6250
1P LCD Meter 10-60A with BOX WM101BC7DL0BOX 2170
1P LCD Meter 10-60A with Optical Port WM101BC7DDH 2200
1P LCD Meter 10-60A with Optical Port + BOX WM101BC7DL0BOX 2530
Trivector Meter Class 0.5
Model ER300P Class 0.5 (Base Mounting)

Trivector Meter Class 1 whole current meter


Model ER300P Class 1 (Base Mounting)

M.R.P.
Description Cat. No. (`)
Per Unit
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5 BM WR300BB1200 20500
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5 BM WR300BB5200 20500
3Ph, 4W TVM 240V ( L-N) 1 A Class 0.5 BM * WR300BC1200 20500
M.R.P.
Description Cat. No. (`) 3Ph, 4W TVM 240V ( L-N) 5 A Class 0.5 BM WR300BC5200 20500
Per Unit 3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5 BM RS485 WR300BB12RS 24600
3Ph, 4W TVM 240 V 10 - 40A BM WR300BC6300 6000 3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5 BM RS485 * WR300BB52RS 24600
3Ph, 4W TVM 240 V 10 - 60A BM WR300BC7300 6660 3Ph, 4W TVM 240V ( L-N) 1 A Cl 0.5 BM RS485 * WR300BC12RS 24600
3Ph, 4W TVM 240 V 10 - 60A BM RS 485 * WR300BC73RS485 9500 3Ph, 4W TVM 240V ( L-N) 5 A Cl 0.5 BM RS485 WR300BC52RS 24600

* - available on request only * - available on request only

Trivector Meter Class 0.2 Meter Reading Instrument


Model ER300P Class 0.2 (Base Mounting)

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.2 BM WR300BB1100 46120 Meter Reading Instrument - (6.5 MB) 990MRIXX00S 80000
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.2 BM WR300BB5100 46120 Meter Reading Instrument - (16.5 MB) 990MRIXX00S1 100000
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.2 BM RS485 WR300BB11RS 49200
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.2 BM RS485 WR300BB51RS 49200

L&T, ESP 01.01.2015 69


Digital Panel Meters
Single Function Meters LED Multifunction Meters
Model VEGA Model VEGA
Features
Features l Accuracy Class 1.0, 0.5
l Accuracy Class 1.0 l Input voltage measurement range
l Input voltage measurement range 17-520 VAC (P-P) 17-520 VAC (P-P)
l Aux supply 90-300VAC l Aux supply 90-300VAC
l Flush mounting 96 X 96 mm l Flush mounting 96 X 96 mm
l Inbuilt selector switch for 3 phase meters l Site selectable 1A /5A New
l CT/PT site programmable l CT/PT site programmable
l Optional RS485 port

Parameters:
Model A: V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours,
On hours, Interrupts, RPM, % Unbalance (V,A), Phase angle, THD. New
Model B: All parameters of Model A + Neutral current, % Load,
Maximum Demand (kW & kVA), MD reset
Ammeter Voltmeter Model C: All parameters of Model B + Bi-directional (Import-Export)

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Single Phase Basic Meters Class 1
1Ph Voltmeter Class 1 WDS101FEV00 1000 Model A, Class 1, RS485 port WDM303FDWA1 7500
1Ph Ammeter, Class 1, 5A WDS101FCA00 1000 Model B, Class 1, RS485 port WDM303FDNB1 11400
1Ph Ammeter, Class 1, 1A WDS101OCA00 1000 Model C, Class 1, RS485 port WDM303FDNC1 16400
1Ph Freq. meter Class 0.2 WDS121FCF00 1000 Model A, Class 1 without RS485 port WDM303FDWAX 6990
Three Phase Basic Meters Model B, Class 1 without RS485 port WDM303FDNBX 10500
3Ph Voltmeter Class 1 WDS301FEV00 1360 Model C, Class 1 without RS485 port WDM303FDNCX 15500
3Ph Ammeter, 5A, Class 1 WDS301FCA00 1360 Class 0.5
3 Ph Ammeter, 1 A, Class 1 WDS301OCA00 1360 Model A, Class 0.5, RS485 port WDM313FDWA1 9000
Model B, Class 0.5, RS485 port WDM313FDNB1 14000
Model C, Class 0.5, RS485 port WDM313FDNC1 20000
* RPM - Rotation per minute

VAF + PF Meters LCD Multifunction Meters


Model VEGA Model NOVA

Features Features
l Accuracy Class 1.0 l Accuracy Class 1.0
l Input voltage measurement range 17-520 VAC (P-P) l Input voltage measurement range 3 X 240 VAC (-30% to 20%)
l Aux supply 90-300VAC l Aux supply 90-300VAC/DC
l Flush mounting 96 X 96 mm l Flush mounting 96 X 96 mm
l CT/PT site programmable l CT/PT site programmable
l Parameters : V, A, F, RPM and PF l Optional RS485 port
l Parameters: V, A, F, PF, kW, kWh

VAF + PF Meter NOVA

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
VAF + PF Meter 3Ph 4 W 240V 5A with RS485 WM30KFC3CRS 4800
3Ph VAF + PF, Class 1, 5A WDV303FC000 2600 3Ph 4W 240V 5A WM30KFC3C00 4300
3Ph VAF + PF, Class 1, 1A WDV303OC000 2600

* RPM - Rotation per minute

L&T, ESP 01.01.2015 71


Digital Panel Meters
LCD Multifunction Meter kWh Meter New
Model QUASAR LCD Type
Features
Features
l Accuracy Class 1.0, 0.5
l Accuracy Class 1.0
l Flush mounting 96 X 96 mm
l Aux supply 90 - 300 VAC
l CT/PT site programmable
l Flush mounting 96 X 96 mm
l Optional RS485 port
l CT/PT site programmable
l Parameters: V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh,
l Optional RS485 port
THD, Phase angles, THD, Power demand.
l Auto scaling of Kilo, Mega and Giga
l Parameter: kWh

M.R.P.
Description Cat. No. (`)
Per Unit
3Ph 4W, 5A, kWh meter Class 1 WM30JFC3C00 3000
3Ph 4W, 5A, kWh meter Class 1 with RS485 port WM30JFC3CRS 3500
M.R.P.
Description Cat. No. (`)
Per Unit
3Ph, 4W IPM 240 V (L-N) 1 A Class 1 FM WI300FC1300 9060
3Ph, 4W IPM 240 V (L-N) 5 A Class 1 FM WI300FC5300 9060
3Ph, 3W IPM 110 V (L-L) 1 A Class 1 FM WI301FC1300 9060
kWh Meter
3Ph, 3W IPM 110 V (L-L) 5 A Class 1 FM WI301FC5300 9060 Model Acrux Counter Type
3Ph, 4W IPM 110 V (L-L) 1 A Class 1 FM WI300FB1300 9060
3Ph, 4W IPM 110 V (L-L) 5 A Class 1 FM WI300FB5300 9060
3Ph, 4W IPM 240 V (L-N) 1 A Class 1 FM with RS485 WI300FC13RS 10130 Features
3Ph, 4W IPM 240 V (L-N) 5 A Class 1 FM with RS485 WI300FC53RS 10130 l Accuracy Class 1.0
3Ph, 3W IPM 110 V (L-L) 1 A Class 1 FM with RS485 WI301FC13RS 10130 l Flush mounting 96 X 96 mm
3Ph, 3W IPM 110 V (L-L) 5 A Class 1 FM with RS485 WI301FC53RS 10130 l Parameter: kWh
3Ph, 4W IPM 110 V (L-L) 1 A Class 1 FM with RS485 WI300FB13RS 10130 Acrux
3PH, 4W IPM 110 V (L-L) 5 A Class 1 FM with RS485 WI300FB53RS 10130
M.R.P.
Description Cat. No. (`)
Per Unit
M.R.P. 3Ph 4 W 240V 1A
Description Cat. No. (`) WM301FC1C10 3200
(kWh meter counter type) - Acrux
Per Unit
3Ph, 4W IPM 240 V (L-N) 1 A Class 0.5 FM WI300FC1200 11190 3Ph 4 W 240V 5A
WM301FC3C10 3200
(kWh meter counter type) - Acrux
3Ph, 4W IPM 240 V (L-N) 5 A Class 0.5 FM WI300FC5200 11190
3Ph, 3W IPM 110 V (L-L) 1 A Class 0.5 FM WI301FC1200 11190
3Ph, 3W IPM 110 V (L-L) 5 A Class 0.5 FM WI301FC5200 11190
3Ph, 4W IPM 110 V (L-L) 1 A Class 0.5 FM WI300FB1200 11190
3Ph, 4W IPM 110 V (L-L) 5 A Class 0.5 FM WI300FB5200 11190
3Ph, 4W IPM 240 V (L-N) 1 A Class 0.5 FM with RS485 WI300FC12RS 12260
3Ph, 4W IPM 240 V (L-N) 5 A Class 0.5 FM with RS485 WI300FC52RS 12260 DIN Energy Meter
3Ph, 3W IPM 110 V (L-L) 1 A Class 0.5 FM with RS485 WI301FC12RS 12260
Model Mi-energy
3Ph, 3W IPM 110 V (L-L) 5 A Class 0.5 FM with RS485 WI301FC52RS 12260
3Ph, 4W IPM 110 V (L-L) 1 A Class 0.5 FM with RS485 WI300FB12RS 12260 Features
3Ph, 4W IPM 110 V (L-L) 5 A Class 0.5 FM with RS485 WI300FB52RS 12260 l Accuracy Class 2.0
l RS485 and Wi-Fi modules available
l Displays day,week, month and push to push consumption
l Parameters: V, A, F, PF, kW, kVA, kVAR, kWh, MD
Dual Source Meter
New New
Model Gemini
Features
l Accuracy Class 1.0
l Input voltage measurement range
3 X 240 VAC (-30% to 20%)
l Aux supply 90-300 VAC/DC
l DG sensing input 10-16 VDC/90-300 VAC
l Flush mounting 96 X 96 mm RS 485 Wi-Fi
1 Phase 3 Phase
l CT/PT site programmable Module Module
l RS485 port available M.R.P.
Gemini l Parameters: V,A, F, kW,kWh - Dual source Description Cat. No. (`)
Per Unit
M.R.P.
Description Cat. No. (`) 1Ph 5-30A, 240V, Class 2 W2DLD050600 2200
Per Unit 3Ph 10-60A, 240V, Class 2 W4DLD100600 5000
3Ph 4 W 240V 5A with RS485 WM30DFC3CRS 4600 RS485 module W1DLD0000RS 2200
Wi-Fi module W1DLD0000WF 5000

72 L&T, ESP 01.01.2015


Programmable Logic Controller (PLC)
l Compact & Powerful l Built-in High speed counter & Pulse Output
l LX7S from 10 to 48 I/O l Built-in real time clock in LX7
l LX7 from 28 to 104 I/O l Ideal for small to mid size machine automation / AMF panels / Load
l 2 serial ports (with Modbus RTU) management / pump control and many more applications
l Built-in backup flash memory l Can communicate with ACB, MCCB Releases, Energy Meters

LX7 / LX7S LX70 LX700

M.R.P.
Type Cat. No. Description (`)
Per Unit
LX7S-10ADR AC Powered, 6 Digital Inputs, 4 Digital Outputs (Relay) 9500
LX7S-10ADT AC Powered, 6 Digital Inputs, 4 Digital Outputs (Transistor) 9300
LX7S-14ADR AC Powered, 8 Digital Inputs, 6 Digital Outputs (Relay) 11200
LX7S-14ADT AC Powered, 8 Digital Inputs, 6 Digital Outputs (Transistor) 10900
LX7S-20ADR AC Powered, 12 Digital Inputs, 8 Digital Outputs (Relay) 13700
LX7S-20ADT AC Powered, 12 Digital Inputs, 8 Digital Outputs (Transistor) 13300
LX7S-28ADR AC Powered, 16 Digital Inputs, 12 Digital Outputs (Relay) 16500
LX7S Series
LX7S-28ADT AC Powered, 16 Digital Inputs, 12 Digital Outputs (Transistor) 16100
(Non Expandable LX7S-40ADR AC Powered, 24 Digital Inputs, 16 Digital Outputs (Relay) 20700
PLC)
LX7S-40ADT AC Powered, 24 Digital Inputs, 16 Digital Outputs (Transistor) 20100
LX7S-48ADR AC Powered, 28 Digital Inputs, 20 Digital Outputs (Relay) 22900
LX7S-48ADT AC Powered, 28 Digital Inputs, 20 Digital Outputs (Transistor) 22200
LX7S-10DDR DC Powered, 6 Digital Inputs, 4 Digital Outputs (Relay) 9500
LX7S-10DDT DC Powered, 6 Digital Inputs, 4 Digital Outputs (Transistor) 9300
LX7S-14DDR DC Powered, 8 Digital Inputs, 6 Digital Outputs (Relay) 11200
LX7S-14DDT DC Powered, 8 Digital Inputs, 6 Digital Outputs (Transistor) 10900
Base Modules
LX7-28ADR AC Powered, 16 Digital Inputs, 12 Digital Outputs (Relay) 21252
LX7-28ADT AC Powered, 16 Digital Inputs, 12 Digital Outputs (Transistor) 20066
LX7-48ADR AC Powered, 28 Digital Inputs, 20 Digital Outputs (Relay) 31510
LX7-48ADT AC Powered, 28 Digital Inputs, 20 Digital Outputs (Transistor) 29298
LX7-28DDR DC Powered, 16 Digital Inputs, 12 Digital Outputs (Relay) 21922
LX7-28DDT DC Powered, 16 Digital Inputs, 12 Digital Outputs (Transistor) 20608
LX7-48DDR DC Powered, 28 Digital Inputs, 20 Digital Outputs (Relay) 33270
LX7 Series
LX7-48DDT DC Powered, 28 Digital Inputs, 20 Digital Outputs (Transistor) 30722
(Expandable LX7-20ADR-4A AC Powered, 12 Digital Inputs, 8 Digital Outputs (Relay), 4 Analog Inputs 24900
PLC)
LX7-20ADR-6A AC Powered, 12 Digital Inputs, 8 Digital Outputs (Relay), 4 Analog Inputs, 2 Analog Outputs 29500
LX7-20ADT-4A AC Powered, 12 Digital Inputs, 8 Digital Outputs (Transistor), 4 Analog Inputs 24400
LX7-20ADT-6A AC Powered, 12 Digital Inputs, 8 Digital Outputs (Transistor), 4 Analog Inputs, 2 Analog Outputs 28800
Expansion Modules
LX7-14EDR Expansion Module, 8 Digital Inputs, 6 Digital Outputs (Relay) 10400
LX7-14EDT Expansion Module, 8 Digital Inputs, 6 Digital Outputs (Transistor) 10100
LX7-28EDR Expansion Module, 16 Digital Inputs, 12 Digital Outputs (Relay) 14300
LX7-28EDT Expansion Module, 16 Digital Inputs, 12 Digital Outputs (Transistor) 13900

LX 70 Series PLC: LX 700 Series PLC:


l Modular structure with variety of I/O modules l Modular structure with high density I/O modules

l Fast & powerful processors to control upto 384 I/O points l Fast & powerful processors to control upto 1600 I/O points

l Built-in PID for process control l Distributed I/O configuration using Remote I/O master & slave

L&T, ESP 01.01.2015 73


Human Machine Interface (HMI)
l Available from 3 to 15 in 8 models l Multiple PLCs, Controllers connectivity. Communication with ACB,
l Touch LCD interface MCCB, Energy Meter
l Modbus Serial, Ethernet, Field bus Communication l Advanced features: Multy - Language, Graphic, Extended Alarms,
l Supports various Fonts and Graphics Recipe, Data Logging, Printing, Password protection, Trends
l Supports various languages - Japanese, Korean etc l Supports scripting

M.R.P.
Type Cat. No. Description (`)
Per Unit

1 LX-TEXTMATE DC Powered, 3, 8-Line Alphanumeric Text Display 10400


2 S04TDAA 4.3" Wide 65536 Color TFT, SRAM, 480X272, 6M Memory(Serial only), DC powered 20000
3 E05TDAA 5.7" 65536 Color TFT, SRAM, 320X240, (Serial/USB/CF/Ethernet), DC powered 50000
4 S07TDAA 7" Wide 65536 Color TFT, SRAM, 800X480, 26M Memory (Serial only), DC powered 29000
5 E08TDAA 8.4" 65536 Color TFT, SRAM, 640*480, (Serial/USB/CF/Ethernet), DC powered 65000
6 E10TDWA 10.4" 65536 Color TFT, SRAM, 800x600, (Serial/USB/CF/Ethernet), DC powered 58000
7 F12TAAA 12.1" 65536 Color TFT, SRAM, 800x600, (Serial/USB/CF/Ethernet, Option: Profibus slave), AC powered 150000
8 F15TAAA 15" 65536 Color TFT, SRAM, 1024x768, (Serial/USB/CF/Ethernet, Option: Profibus slave), AC powered 200000

74 L&T, ESP 01.01.2015


Miniature Circuit Breaker (MCB)
Range Highlights
l True contact indication for individual pole
l Label holder facility for all configurations
l Conforms to IS/IEC 60898
l Breaking capacity of 10kA throughout the range
l Available in B, C & D curves
l Low watt loss - almost 50% of the values prescribed by IS/IEC 60898
l Trip free mechanism
l Design based on advanced current limiting hammer trip mechanism
l No Line-Load bias
l Suitable for accessory fitment
l Suitable for DC application, as per IEC 60947-2
- Rated Voltage:130V DC (for SP), 250V DC (for DP) with breaking capacity of 6kA

Current M.R.P. M.R.P. M.R.P.


Modules B-Curve C-Curve D-Curve
Rating (`) (`) (`)
1 Mod = 17.5mm Cat. No. Cat. No. Cat. No.
(In) Per Unit Per Unit Per Unit

Single Pole (SP)

0.5A 1 - - BB10E50C 315 BB10E50D 325


1A 1 - - BB10010C 315 BB10010D 325
2A 1 - - BB10020C 315 BB10020D 325
3A 1 - - BB10030C 315 BB10030D 325
4A 1 - - BB10040C 315 BB10040D 325
6A 1 BB10060B 216 BB10060C 216 BB10060D 285
10A 1 BB10100B 216 BB10100C 216 BB10100D 285
16A 1 BB10160B 216 BB10160C 216 BB10160D 285
20A 1 BB10200B 216 BB10200C 216 BB10200D 285
25A 1 BB10250B 216 BB10250C 216 BB10250D 285
32A 1 BB10320B 216 BB10320C 216 BB10320D 285
40A 1 BB10400B 510 BB10400C 510 BB10400D 525
50A 1 BB10500B 510 BB10500C 510 * *
63A 1 BB10630B 510 BB10630C 510 * *

Double Pole (DP)

0.5A 2 - - BB20E50C 840 BB20E50D 860


1A 2 - - BB20010C 840 BB20010D 860
2A 2 - - BB20020C 840 BB20020D 860
3A 2 - - BB20030C 840 BB20030D 860
4A 2 - - BB20040C 840 BB20040D 860
6A 2 BB20060B 670 BB20060C 670 BB20060D 705
10A 2 BB20100B 670 BB20100C 670 BB20100D 705
16A 2 BB20160B 670 BB20160C 670 BB20160D 705
20A 2 BB20200B 670 BB20200C 670 BB20200D 705
25A 2 BB20250B 670 BB20250C 670 BB20250D 705
32A 2 BB20320B 670 BB20320C 670 BB20320D 705
40A 2 BB20400B 1130 BB20400C 1130 BB20400D 1150
50A 2 BB20500B 1130 BB20500C 1130 * *
63A 2 BB20630B 1130 BB20630C 1130 * *

Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
* Available on request

76 L&T, ESP 01.01.2015


Miniature Circuit Breaker (MCB)

Current M.R.P. M.R.P. M.R.P.


Rating Modules B-Curve C-Curve D-Curve
(`) (`) (`)
(In) 1 Mod = 17.5mm Cat. No. Cat. No. Cat. No.
Per Unit Per Unit Per Unit

Three Pole (TP)

0.5A 3 - - BB30E50C 1160 BB30E50D 1180


1A 3 - - BB30010C 1160 BB30010D 1180
2A 3 - - BB30020C 1160 BB30020D 1180
3A 3 - - BB30030C 1160 BB30030D 1180
4A 3 - - BB30040C 1160 BB30040D 1180
6A 3 BB30060B 1080 BB30060C 1080 BB30060D 1100
10A 3 BB30100B 1080 BB30100C 1080 BB30100D 1100
16A 3 BB30160B 1080 BB30160C 1080 BB30160D 1100
20A 3 BB30200B 1080 BB30200C 1080 BB30200D 1100
25A 3 BB30250B 1080 BB30250C 1080 BB30250D 1100
32A 3 BB30320B 1080 BB30320C 1080 BB30320D 1100
40A 3 BB30400B 1680 BB30400C 1680 BB30400D 1700
50A 3 BB30500B 1680 BB30500C 1680 * *
63A 3 BB30630B 1680 BB30630C 1680 * *

Four Pole (FP)

0.5A 4 - - BB40E50C 1665 BB40E50D 1690


1A 4 - - BB40010C 1665 BB40010D 1690
2A 4 - - BB40020C 1665 BB40020D 1690
3A 4 - - BB40030C 1665 BB40030D 1690
4A 4 - - BB40040C 1665 BB40040D 1690
6A 4 BB40060B 1460 BB40060C 1460 BB40060D 1480
10A 4 BB40100B 1460 BB40100C 1460 BB40100D 1480
16A 4 BB40160B 1460 BB40160C 1460 BB40160D 1480
20A 4 BB40200B 1460 BB40200C 1460 BB40200D 1480
25A 4 BB40250B 1460 BB40250C 1460 BB40250D 1480
32A 4 BB40320B 1460 BB40320C 1460 BB40320D 1480
40A 4 BB40400B 2100 BB40400C 2100 BB40400D 2120
50A 4 BB40500B 2100 BB40500C 2100 * *
63A 4 BB40630B 2100 BB40630C 2100 * *

Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP- 4 Nos., FP - 3 Nos.
* Available on request

Auxiliary & Accessories for MCBs


M.R.P.
Description Cat. No. (`)
Per Unit
Auxiliary Contact - 6A (1NO+1NC), 0.5 Mod BZA11006 630
Shunt Release - 240V AC, 1 Mod BZS00240 1675
Trip Alarm Contact - 240V AC, (1NO+1NC), 0.5 Mod BZT11006 735

L&T, ESP 01.01.2015 77


Residual Current Circuit Breaker (RCCB)
Range Highlights
l Conforms to IS 12640 (Part 1) / IEC 61008-1

l RCCBs are available in DP and FP versions from 25 to 100A ratings with 30 mA, 100 mA and 300 mA sensitivity

l Truly current operated - operation even at nominal voltage

l Operates on Core Balance Current Transformer (CBCT) principle

l Operation even in case of neutral failure

l Advanced neutral mechanism

Current M.R.P. Current M.R.P.


Rating Sensitivity Modules Rating Sensitivity Modules
Cat. Nos. (`) Cat. Nos. (`)
(In) 1 Mod = 17.5 mm (In) 1 Mod = 17.5 mm
Per Unit Per Unit
Double Pole (DP) Four Pole (FP)
30 mA 2 BG202503 2400 30 mA 4 BG402503 3050
25A 100 mA 2 BG202510 2460 25A 100 mA 4 BG402510 3090
300 mA 2 BG202530 2460 300 mA 4 BG402530 3090
30 mA 2 BG204003 2690 30 mA 4 BG404003 3160
40A 100 mA 2 BG204010 2730 40A 100 mA 4 BG404010 3200
300 mA 2 BG204030 2730 300 mA 4 BG404030 3200
30 mA 2 BG206303 3400 30 mA 4 BG406303 3555
63A 100 mA 2 BG206310 3440 63A 100 mA 4 BG406310 3600
300 mA 2 BG206330 3440 300 mA 4 BG406330 3600
30 mA 2 BG210003 5950 30 mA 4 BG410003 6300
100A 100 mA 2 BG210010 5995 100A 100 mA 4 BG410010 6370
300 mA 2 BG210030 5995 300 mA 4 BG410030 6370

Isolators
Range Highlights
l Conforms to IEC 60947-3

l Utilization category AC-22A

l Available in DP, TP and FP versions in 40A, 63A, 80A & 100A ratings

Current M.R.P. M.R.P. M.R.P.


Rating Modules Modules Modules
Cat. No. (`) Cat. No. (`) Cat. No. (`)
(In) 1 Mod = 17.5 mm 1 Mod = 17.5 mm 1 Mod = 17.5 mm
Per Unit Per Unit Per Unit
Double Pole (DP) Three Pole (TP) Four Pole (FP)
40A 2 BF204000 415 3 BF304000 740 4 BF404000 940
63A 2 BF206300 535 3 BF306300 840 4 BF406300 970
80A 2 BF208000 690 3 BF308000 915 4 BF408000 1105
100A 2 BF210000 720 3 BF310000 930 4 BF410000 1135

Note: Standard Pack Quantity for Isolator : DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.

78 L&T, ESP 01.01.2015


Other Protection & Control Devices
Modular Indicator Surge Protection Device

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Single Phase Indicator-Red 1 Mod MM1NDV04 590 Type 2 SPDs - (8/20 micro sec)
Single Phase Indicator-Yellow 1 Mod MM1NDW04 590 40kA, 1P+N, 1 Mod LPDA2040P2 7500
Single Phase Indicator-Blue 1 Mod MM1NDX04 590 40kA, 3P+N, 2 Mod LPDA2040P4 15000
Three Phase Indicator-Red, Yellow & Blue 1Mod MM3ND04 800 15kA, 1P+N, 1 Mod LPDA2015P2 6000
15kA, 3P+N, 2 Mod LPDA2015P4 11800
Type 1+2 SPDs are available
For more details please contact nearest L&T branch office.

Analog Time Switch Modular Energy Meter

M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
Time Switch - 1 Mod (1 NO) J6107B204 2450 1-Phase 2-wire 240V, 5-30A W2DLD050600 2200
Time Switch - 3 Mod (1 C/O) J6118B304 2400 3-Phase 4-Wire 240V 10-60A W4DLD100600 5000

Digital Time Switch Single Phase ACCL

Automatic Source Changeover


With Current Limiter

M.R.P. Description M.R.P.


Description Cat. No. (`) Cat. No. (`)
EB/DG (Load)
Per Unit Per Unit
Crono Time Switch 110-240V AC 1 C/O- 2 Mod 67DDT0 1875 30A/1.5A (300W) ACCL113001O 1500
Pulse Time Switch, 110-240V AC 1 C/O- 2 Mod 67DDT9 1825 30A/2.5A (500W) ACCL113002O 1500
30A/3A (600W) ACCL113003O 1500
30A/4A (800W) ACCL113004O 1500
30A/5A (1000W) ACCL113005O 1500
Astronomical Time Switch 30A/6A (1200W) ACCL113006O 1500
30A/8A (1600W) ACCL113008O 1500
30A/10A (1800W) ACCL113010O 1500

M.R.P.
Description Cat. No. (`)
Per Unit
Astronomical Time Switch
T2DDT7 3150
110-240V 1 C/O - 2 Mod

L&T, ESP 01.01.2015 79


Selection Chart: Fuse Protected Feeders
TYPE '2' Co-ordination, Iq=50 kA at 415V, 3, 50 Hz as per IS/IEC 60947-4-1 standard
l The Full Load Current (FLC) indicated for 3-phase motors are of 'squirrel-cage Induction motors' at full load.
l Contactors / S-D-Fs indicated are of the minimum ratings. Higher rating of contactors and S-D-Fs can be used.
l Selection chart is for standard 3-phase, squirrel cage motor with average power factor and efficiency.
l Selection is valid only for complete L&T combinations.
l Compliance to Type '2' co-ordination is not assured in case these combinations are changed to accommodate another brand / rating of
products like S-D-F / Fuse etc.
l All S-D-F ratings are AC-23A as per IS/IEC 60947-3, IEC 60947-3 & EN 60947-3
l Normal motor starting time (<=5 Sec) is assumed. Selection for motors with longer starting times can be made available on request.
l For detailed Type 2 charts for fuseless feeders, kindly contact the nearest branch office.

DOL Starter Feeders with Fuse for IE1/IE2 Motors


Motor: 3, 415V, 50 Hz Contactor Overload Relay Nominal Backup fuse
S-D-F
hp kW In (A) Type Type Range (A) Type Rating (A)
0.16 0.12 0.51 MNX 9 MN 2 0.45 - 0.75 HF 2 FN 32
0.25 0.18 0.6 MNX 9 MN 2 0.45 - 0.75 HF 2 FN 32
0.33 0.25 0.8 MNX 9 MN 2 0.6 - 1.0 HF 2 FN 32
0.5 0.37 1.2 MNX 9 MN 2 0.9 - 1.5 HF 4 FN 32
0.75 0.55 1.5 MNX 9 MN 2 1.4 - 2.3 HF 4 FN 32
1 0.75 2 MNX 9 MN 2 1.4 - 2.3 HF 6 FN 32
1.5 1.1 2.7 MNX 9 MN 2 2.0 - 3.3 HF 8 FN 32
1.75 1.3 3 MNX 9 MN 2 2.0 - 3.3 HF 8 FN 32
2 1.5 3.5 MNX 9 MN 2 3-5 HF 10 FN 32
3 2.2 4.9 MNX 9 MN 2 4.5 - 7.5 HF 16 FN 32
4 3 6 MNX 9 MN 2 4.5 - 7.5 HF 16 FN 32
5 3.7 7.5 MNX 9 MN 2 4.5 - 7.5 HF 20 FN 32
5.5 4 8.5 MNX 9 MN 2 6 - 10 HF 20 FN 32
7.5 5.5 11 MNX 12 MN 2 9 - 15 HF 32 FN 32
10 7.5 14.5 MNX 22 MN 2 9 - 15 HF 40 FN 63
12.5 9.3 17.3 MNX 25 MN 2 14 - 23 HF 50 FN 63
15 11 21 MNX 25 MN 2 14 - 23 HF 63 FN 63
17.5 13 24 MNX 25 MN 2 20 - 33 HF 63 FN 63
20 15 29 MNX 40 MN 2 20 - 33 HN, 000* 63 FN 100
25 18.5 35 MNX 40 MN 2 24 - 40 HN, 000* 80 FN 100
30 22 40 MNX 45 MN 5 30 - 50 HN, 000* 80 FN 100
40 30 54 MNX 70 MN 5 45 - 75 HN, 000* 100 FN 100
50 37 68 MNX 80 MN 5 45 - 75 HN, 000 125 FN 125
60 45 81 MNX 95 MN 5 66 - 110 HN, 000 125 FN 125
75 55 94 MNX 95 MN 5 66 - 110 HN, 00# 160 FN 160
100 75 130 MNX 140 MN 12 90 - 150 HN, 0 200 FN 200
110 80 139 MNX 140 MN 12 90 - 150 HN, 0 200 FN 200
120 90 157 MNX 185 MN 12 135 - 225 HN, 1 250 FN 250
150 110 189 MNX 225 MN 12 135 - 225 HN, 1 250 FN 250
170 125 207 MNX 250 MN 12 135 - 225 HN, 1 315 FN 315
180 132 226 MNX 250 MN 12 180 - 300 HN, 1 315 FN 315
200 150 248 MNX 265 MN 12 180 - 300 HN, 2 400 FN 400
215 160 270 MNX 300 MN 12 180 - 300 HN, 2 400 FN 400
240 180 298 MNX 325 MN 12 180 - 300 HN, 2 400 FN 400
270 200 336 MNX 400 MN 12 270 - 450 HN, 3 500 FN 630
300 225 360 MNX 400 MN 12 270 - 450 HN, 3 500 FN 630
335 250 420 MNX 550 MN 12 270 - 450 HN, 3 500 FN 630
370 275 440 MNX 550 MN 12 270 - 450 HN, 3 630 FN 630
425 315 529 MNX 550 MN 12L 340 - 570 HN, 3 630 FN 630
452 335 550 MNX 650 MN 12L 340 - 570 HN, 3 800 FN 800

* : Only size '000' fuses to be used with FN 100 S-D-F.


# : Only size '00' fuses to be used with FN 160 S-D-F.

80 L&T, ESP 01.01.2015


Selection Chart: Fuse Protected Feeders
Star Delta Starter Feeders with Fuse for IE1/IE2 Motors
R

Fuse

Note : It is recommended that Star Delta configuration is used


along with Star-Delta Timer with Pause Time and not On-Delay
Timer. Recommended timer Cat No is 12SDT0.

Line Delta Star


Contactor Contactor Contactor

Relay

V1
U1 W1

3 Motor
V2 U2
W2

Ratings at 3, 415V, 50 Hz
Contactor Overload Relay Nominal Back up fuse
Current, In (A) S-D-F
hp kW
Line Phase Star Line Delta Type Range (A) Type Rating (A)
1 0.75 2 1.2 MNX 9 MNX 9 MNX 9 MN 2 0.9 - 1.5 HF 4 FN 32
1.5 1.1 2.7 1.6 MNX 9 MNX 9 MNX 9 MN 2 1.4 - 2.3 HF 4 FN 32
1.75 1.3 3 1.7 MNX 9 MNX 9 MNX 9 MN 2 1.4 - 2.3 HF 4 FN 32
2 1.5 3.5 2.0 MNX 9 MNX 9 MNX 9 MN 2 1.4 - 2.3 HF 6 FN 32
3 2.2 4.92 2.8 MNX 9 MNX 9 MNX 9 MN 2 2 - 3.3 HF 8 FN 32
4 3 6 3.5 MNX 9 MNX 9 MNX 9 MN 2 3-5 HF 8 FN 32
5 3.7 7.5 4.3 MNX 9 MNX 9 MNX 9 MN 2 3-5 HF 10 FN 32
5.5 4 8.5 4.9 MNX 9 MNX 9 MNX 9 MN 2 3-5 HF 16 FN 32
7.5 5.5 11 6.4 MNX 9 MNX 9 MNX 9 MN 2 4.5 - 7.5 HF 16 FN 32
10 7.5 14.5 8.4 MNX 9 MNX 9 MNX 9 MN 2 6 - 10 HF 20 FN 32
12.5 9.3 17.3 10.0 MNX 9 MNX 12 MNX 12 MN 2 9 - 15 HF 32 FN 32
15 11 21 12.0 MNX 9 MNX 12 MNX 12 MN 2 9 - 15 HF 32 FN 32
17.5 13 24 13.9 MNX 12 MNX 18 MNX 18 MN 2 9 - 15 HF 32 FN 32
20 15 29 16.7 MNX 12 MNX 22 MNX 22 MN 2 14 - 23 HF 40 FN 63
25 18.5 35 20.2 MNX 18 MNX 25 MNX 25 MN 2 14 - 23 HF 50 FN 63
30 22 40 23.1 MNX 18 MNX 25 MNX 25 MN 2 20 - 33 HF 63 FN 63
40 30 54 31.2 MNX 32 MNX 32 MNX 32 MN 2 20 - 33 HN, 000* 63 FN 100
50 37 68 39.3 MNX 32 MNX 45 MNX 45 MN 5 30 - 50 HN, 000* 80 FN 100
60 45 81 46.8 MNX 45 MNX 70 MNX 70 MN 5 30 - 50 HN, 000* 100 FN 100
75 55 94 54.3 MNX 45 MNX 70 MNX 70 MN 5 45 - 75 HN, 000* 100 FN 100
100 75 130 75.1 MNX 80 MNX 95 MNX 95 MN 5 66 - 110 HN, 00# 160 FN 160
110 80 139 80.3 MNX 80 MNX 95 MNX 95 MN 5 66 - 110 HN, 00# 160 FN 160
120 90 157 90.6 MNX 80 MNX 95 MNX 95 MN 5 66 - 110 HN, 00# 160 FN 160
150 110 189 109 MNX 95 MNX 110 MNX 110 MN 5 66 - 110 HN, 0 200 FN 200
170 125 207 120 MNX 95 MNX 140 MNX 140 MN 12 90 - 150 HN, 1 250 FN 250
180 132 226 130 MNX 110 MNX 140 MNX 140 MN 12 90 - 150 HN, 1 250 FN 250
200 150 248 143 MNX 110 MNX 185 MNX 185 MN 12 135 - 225 HN, 1 250 FN 250
215 160 270 156 MNX 140 MNX 225 MNX 225 MN 12 135 - 225 HN, 1 315 FN 315
240 180 298 172 MNX 140 MNX 225 MNX 225 MN 12 135 - 225 HN, 1 315 FN 315
270 200 336 194 MNX 250 MNX 265 MNX 265 MN 12 135 - 225 HN, 2 400 FN 400
300 225 360 208 MNX 250 MNX 265 MNX 265 MN 12 135 - 225 HN, 2 400 FN 400
335 250 420 242 MNX 265 MNX 325 MNX 325 MN 12 180 - 300 HN, 3 500 FN 630
370 275 440 254 MNX 265 MNX 325 MNX 325 MN 12 180 - 300 HN, 3 500 FN 630
425 315 529 305 MNX 325 MNX 550 MNX 550 MN 12 270 - 450 HN, 3 630 FN 630
452 335 550 318 MNX 400 MNX 550 MNX 550 MN 12 270 - 450 HN, 3 630 FN 630
475 355 589 340 MNX 400 MNX 550 MNX 550 MN 12 270 - 450 HN, 3 630 FN 630
502 375 615 355 MNX 400 MNX 550 MNX 550 MN 12 270 - 450 HN, 3 630 FN 630
535 400 674 389 MNX 550 MNX 650 MNX 650 MN 12 340 - 570 HN, 3 800 FN 630

* : Only size '000' fuses to be used with FN 100 S-D-F.


# : Only size '00' fuses to be used with FN 160 S-D-F.

L&T, ESP 01.01.2015 81


Selection Chart: MPCB DOL Starters
DOL Starter Feeders with MPCB for IE1 Motors
R
Motor Rating: 3, 415V, 50 Hz Contactor MPCB Y
Type B
hp kW FLC, In (A) Type Range (A)

0.16 0.12 0.51 MO 9 MOG-S1 / MOG-H1 0.4 - 0.63


0.25 0.18 0.6 MO 9 MOG-S1 / MOG-H1 0.4 - 0.63
0.33 0.25 0.8 MO 9 MOG-S1 / MOG-H1 0.63 - 1
0.5 0.37 1.2 MO 9 MOG-S1 / MOG-H1 1 - 1.6
MPCB
0.75 0.55 1.5 MO 9 MOG-S1 / MOG-H1 1 - 1.6
Overload + Short
1 0.75 2 MO 9 MOG-S1 / MOG-H1 1.6 - 2.5
circuit protection
1.5 1.1 2.7 MO 12 MOG-S1 / MOG-H1 2.5 - 4
1.75 1.3 3 MO 12 MOG-S1 / MOG-H1 2.5 - 4
2 1.5 3.5 MO 12 MOG-S1 / MOG-H1 2.5 - 4
3 2.2 4.9 MO 18 MOG-S1 / MOG-H1 4 - 6.3
4 3 6 MO 18 MOG-S1 / MOG-H1 4 - 6.3
5 3.7 7.5 MO 25 MOG-S1 / MOG-H1 6.3 - 10
5.5 4 8.5 MO 25 MOG-S1 / MOG-H1 6.3 - 10 Contactor
7.5 5.5 11 MO 25 MOG-S1 / MOG-H1 9 - 13
10 7.5 14.5 MO 25 MOG-H1 11 - 16
12.5 9.3 17.3 MO 32 MOG-H1 14 - 20
No separate
15 11 21 MO 32 MOG-H1 19 - 25
overload relay
17.5 13 24 MO 45 MOG-H1 24 - 32
20 15 29 MO 45 MOG-H1 24 - 32
25 18.5 35 MO 50 MOG-H2 28 - 40
30 22 40 MO 50 MOG-H2 35 - 50 Motor
40 30 54 MO 80 MOG-H2 45 - 63

DOL Starter Feeders with MPCB for IE2 Motors

Motor Rating: 3, 415V, 50 Hz Contactor MPCB


Type
hp kW FLC, In (A) Type Range (A)

0.16 0.12 0.51 MO 9 MOG-S1 / MOG-H1 0.4 - 0.63


0.25 0.18 0.6 MO 9 MOG- S1 / MOG-H1 0.63 - 1
0.33 0.25 0.8 MO 9 MOG-S1 / MOG-H1 0.63 - 1
0.5 0.37 1.2 MO 9 MOG- S1 / MOG-H1 1 - 1.6
0.75 0.55 1.5 MO 9 MOG-S1 / MOG-H1 1 - 1.6
1 0.75 2 MO 9 MOG- S1 / MOG-H1 1.6 - 2.5
1.5 1.1 2.7 MO 12 MOG-S1 / MOG-H1 2.5 - 4
1.75 1.3 3 MO 12 MOG- S1 / MOG-H1 2.5 - 4
2 1.5 3.5 MO 12 MOG-S1 / MOG-H1 2.5 - 4
3 2.2 4.9 MO 18 MOG- S1 / MOG-H1 4 - 6.3
4 3 6 MO 25 MOG-S1 / MOG-H1 6.3 - 10
5 3.7 7.5 MO 25 MOG- S1 / MOG-H1 6.3 - 10
5.5 4 8.5 MO 25 MOG-S1 / MOG-H1 6.3 - 10
7.5 5.5 11 MO 25 MOG- S1 / MOG-H1 9 - 13
10 7.5 14.5 MO 25 MOG - H1 11 - 16
15 11 21 MO 32 MOG - H1 19 - 25
17.5 13 24 MO 45 MOG - H1 24 - 32
20 15 29 MO 50 MOG - H2 28 - 40
25 18.5 35 MO 50 MOG - H2 35 - 50
30 22 40 MO 60 MOG - H2 35 - 50

82 L&T, ESP 01.01.2015


Air Insulated MV Switchgear
Type tested indoor MV Panel upto 36 kV system voltage
Complete range from 630A to 4000A
Short time rating upto 40 kA for 3sec
Metal clad, fully compartmentalised panel
Floor mounted VCB
Internal Arc compliant as per IEC 62271-200
In-built comprehensive safety interlocks
N e w
Discontinued Products/Suggested Alternate Products
The following products have been discontinued :

Product Group Discontinued Products Suggested Alternate Products

ET 100 ST100

MN0 AC MO0 AC

Controlgear MCX 11-11 Mechanically interlocked contactor (factory fitted) MCX 11 contactor can be ordered with separate MIL kit

MCX 12-12 Mechanically interlocked contactor (factory fitted) MCX 12 contactor can be ordered with separate MIL kit

MCX 13-13 Mechanically interlocked contactor (factory fitted) MCX 13 contactor can be ordered with separate MIL kit

Starter MH0 1 Phase Starter MU-2P DOL Starter

Air Circuit Breakers 3200A & 4000A - H0 Range 3200A & 4000A - H2 Range

FAC100 S-D-F & Accessories FN100


S-D-F
FFO32/FF63 & Accessories FN32 / FN63

FN1000H Switch Disconnector C-Line 1000A Switch Disconnector


S-D
FG Switch Disconnectors : 1250A to 3150A & Accessories C-Line Switch Disconnectors : 1250A to 2000A

Size A1 Bolted Fuse Links : 2A to 32A


Fuses
Size C3, 630A Bolted Fuse Link

Changeover Switches FGC Changeover Switches : 1250A, 1600A & Accessories C-Line Changeover Switches : 1250A, 1600A

DU125 DU250 (125A)

DU160/DU200/DH200 DU250 (160A, 200A)

Moulded Case Circuit Breakers DH160 DU250 (160A) / DN1-250 (160A)

DH250 dsine DN2-250D

DH400/DH630 dsine DN3B-400D/DN3-630D

MC31A MC31AnX

Protective Relays MC61A MC61AnX

MC61C MC61CnX

L&T, ESP 01.01.2015 85


All prices are on maximum retail price basis inclusive of
Excise Duty and VAT / Sales Tax as applicable.

General Prices are subject to revision without notice.

Terms

All the products listed in the price list carry a warranty,


against manufacturing defects for a period of 18* months
from the date of purchase.

Warranty Should the product prove to be defective due to faulty


workmanship or otherwise, we will remedy the defect or

Policy replace the faulty parts or the whole product at our


discretion, as soon as possible, free of cost.

The warranty is however subject to the provision of proper


usage, efficient maintenance and does not cover defects
arising out of fire, accident, inefficient maintenance, faulty
operation and willful or accidental damage. It also does not
cover damage to power electronic components like
thyristors & IGBTs, which fail predominantly due to over-
temperature & over-voltage. The user needs to take
adequate precautions to eliminate these conditions. The
manufacturer shall not be liable for any consequential loss,
injury or damages attributable to defect or failure of
its products.

L&T has over five decades of experience in providing


after sales service for low voltage distribution systems in
every type of industry & commercial complex in India.

Comprehensive L&T offers the following services, partnering you


in your maintenance of low voltage distribution products :

Service Support
Regular Maintenance
Preventive Maintenance Programme
On Call
Annual Maintenance Contract
Product Support for Managing Obsolescence -
Retrofitting & Upgradation of your switchgear products.

86 L&T, ESP 01.01.2015


Touching Lives, Spreading Smiles
Family Welfare, Health, Education & Skill-building help transform lives across the nation.
Electrical Standard Products (ESP) Offices:

HEAD OFFICE Khairasol, Degaul Avenue L&T Business Park,


L&T Business Park, Durgapur 713 212 Tower 'B' / 5th Floor
Tower 'B' / 3rd Floor Tel: 2559848, 2559849, 2559844 Saki Vihar Road, Powai
Saki Vihar Road, Powai Fax: 0343-2553614 Mumbai 400 072
Mumbai 400 072 e-mail: esp-dgp@LNTEBG.com Tel: 022-67052874 / 2737 / 1156
Tel: 022-67053229 Fax: 022-67051112
Fax: 022-67051112 5, Milanpur Road, Bamuni Maidan e-mail: esp-bom@LNTEBG.com
e-mail: cic@LNTEBG.com Guwahati 781 021
Tel: +91 8876554410 / 8876554417 12, Shivaji Nagar
BRANCH OFFICES Fax: 361-2551308 North Ambajhari Road
501, Sakar Complex I e-mail: esp-ghy@LNTEBG.com Nagpur 440 010
Opp. Gandhigram Rly. Station Tel: 0712-2260012 / 6606421
Ashram Road II Floor, Vasantha Chambers Fax: 2260030 / 6606434
Ahmedabad 380 009
5-10-173, Fateh Maidan Road e-mail: esp-nag@LNTEBG.com
Tel: 079-66304006-11
Hyderabad 500 004
Fax: 079-66304025
e-mail: esp-ahm@LNTEBG.com Tel: 040-67015052 32, Shivaji Marg
Fax: 040-23296468 P. O. Box 6223
38, Cubbon Road, P. O. Box 5098 e-mail: esp-hyd@LNTEBG.com New Delhi 110 015
Bangalore 560 001 Tel: 011-41419514 / 5 / 6
Tel: 080-25020100 / 25020324 Monarch Building, 1st Floor Fax: 011-41419600
Fax: 080-25580525 D-236 & 237, Amrapali Marg e-mail: esp-del@LNTEBG.com
e-mail: esp-blr@LNTEBG.com Vaishali Nagar
Jaipur 302 021 L&T House
131/1, Zone II Tel: 0141-4385914 to 18 P. O. Box 119
Maharana Pratap Nagar Fax: 0141-4385925 191/1, Dhole Patil Road
Bhopal 462 011 e-mail: esp-jai@LNTEBG.com Pune 411 001
Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Tel: 020-66033395 / 66033279
Fax: 0755-3080502 Akashdeep Plaza, 2nd Floor Fax: 020-26164048 / 26164910
e-mail: esp-bho@LNTEBG.com P. O. Golmuri e-mail: esp-pnq@LNTEBG.com
Jamshedpur 831 003
Plot No. 559, Annapurna Complex Jharkhand Crystal Tower,
Lewis Road Tel: 0657-2312205 / 38 4th Floor, G. E. Road
Bhubaneswar 751 014 Fax: 0657-2341250 Telibandha
Tel: 0674-6451342, 2436690, 2436696 e-mail: esp-jam@LNTEBG.com Raipur - 492 006
Fax: 0674-2537309 Tel: 0771-4283214
e-mail: esp-bsr@LNTEBG.com Skybright Bldg; M. G. Road e-mail: esp-raipur@LNTEBG.com
Ravipuram Junction, Ernakulam
Aspire Towers, 4th Floor Kochi 682 016 3rd Floor
Plot No. 55, Phase-I Tel: 0484-4409420 / 4 / 5 / 7 Vishwakarma Chambers
Industrial & Business Park Fax: 0484-4409426 Majura Gate, Ring Road
Chandigarh-160 002
e-mail: esp-cok@LNTEBG.com Surat 395 002
Tel: 0172-4646840 / 41 / 42 / 46 / 53
Fax: 0172-4646802 Tel: 0261-2473726
Email: esp-chd@Lntebg.com 3-B, Shakespeare Sarani Fax: 0261-2477078
Kolkata 700 071 e-mail: esp-sur@LNTEBG.com
L&T Construction Campus Tel: 033-44002572 / 3 / 4
TC-1 Building, II Floor Fax: 033-22821025 / 7587 Radhadaya Complex
Mount-Poonamallee Road e-mail: esp-ccu@LNTEBG.com Old Padra Road
Manapakkam Near Charotar Society
Chennai 600 089 A28, Indira Nagar, Faizabad Road Vadodara 390 007
Tel: 044-2270 6800 Lucknow 226 016 Tel: 0265-6613610 / 1 / 2
Fax: 044-22706940 Tel: 0522-4929905 / 04 Fax: 0265-2336184
e-mail: esp-maa1@LNTEBG.com Fax: 0522-2311671 e-mail: esp-bar@LNTEBG.com
e-mail: esp-Lko@LNTEBG.com
67, Appuswamy Road Door No. 49-38-14/3/2, 1st floor,
Post Bag 7156 No: 73, Karpaga Nagar, 8th Street NGGO's Colony, Akkayyapalem,
Opp. Nirmala College K. Pudur Visakhapatnam - 530 016
Coimbatore 641 045 Madurai 625 007 Phone : 0891 2791126, 2711125
Tel: 0422-2588120 / 1 / 5 Tel: 0452-2537404, 2521068 Fax.: 0891 2791100
Fax: 0422-2588148 Fax: 0452-2537552 Email: esp-viz@LNTEBG.com
e-mail: esp-cbe@LNTEBG.com e-mail: esp-mdu@LNTEBG.com

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

Larsen & Toubro Limited, Electrical Standard Products


Powai Campus, Mumbai 400 072
Customer Interaction Center (CIC)
BSNL / MTNL (toll free) : 1800 233 5858
Reliance (toll free) : 1800 200 5858
Tel : 022 6774 5858, Fax : 022 6774 5859
E-mail : cic@LNTEBG.com / Website : www.LNTEBG.com
CIN : L99999MH1946PLC004768

SP 50494 L

You might also like