You are on page 1of 14

GREENBUILDINGCOUNCILINDONESIA

GREENSHIPRATINGTOOLS
ForExistingBuilding
VERSION1.0



GREENSHIPEXISTINGBUILDING

Version1.0



BENCHMARKSUMMARY




RATING&TECHNOLOGIESDIVISION
GREENBUILDINGCOUNCILINDONESIA
JANUARY2011

www.gbcindonesia.org

GREENSHIPEXISTINGBUILDINGVersion1.0
BENCHMARKSUMMARY
EVALUATION
POINT
CODE RATING BENCMARK
MAX
POINT
POINT
APPROPRIATESITEDEVELOPMENT 16
Theavailabilityofawrittenstatementcontainingthe
commitmentfromtopmanagementregardingthe
SiteManagement
P1 exteriorbuildingmaintenance,integratedpest P P
Policy
management(IPM),andweedsandalsohabitat
managementaroundthesiteusingnontoxicmaterials.
Theavailabilityofawrittenstatementcontainingthe
commitmentfromtopmanagementtoperformvarious
actionstoachievethereductionofprivatevehicles, P
suchascarpooling,feederbuses,publictransportation
MotorVehicle
P2 vouchersanddiscriminationofparkingfares. P
ReductionPolicy
Theavailabilityofacampaignwhichincludesthe
positiveimpactfromthereductionofprivatevehicles
P
withaminimuminstallationcampaignispermanently
writtenoneveryfloor,suchassticker,poster,email.
1 Thereareatleast5typesofpublicfacilitieswithina
distanceofachievingthemainroadasfaras1500m 1
fromthesite.
2 Providepedestrianfacilitieswhicharesafe,comfortable
andfreefromcrossovervehicleaccesstoconnectat
least3publicfacilitiesaboveand/orbymass 1
transportationstations.
3A Theavailabilityofpublictransportstopsorstations
within300mfromthegateoutsidethebuildingwith
thecalculationexcludepedestrianbridgeandramp. 1
ASD Community
OR 2
1 Accessibility
3B Provideashuttlebusforthebuildinguserstoreachthe
publictransportationstationsorcarpoolingwhichis
integratedwiththeshuttlebus.Minimumnumbersof 1
busare2units.
OR
3C Providepedestrianfacilitieswithinthethebuildingarea
toreachthebusstoporthenearestpublictransport
station,safelyandacomfortablyinaccordancewith 1
MinisterofPublicWorksDecreeNo30/PRT/M/2006
Chapter2B.
Theavailabilityoftheimplementationforoneofthe
ASD MotorVehicle
options:carpooling,feederbuses,publictransportation 1 1
2 Reduction
vouchers,anddiscriminationofparkingfares.

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | i

1 Theavailability of a secure bicycle parking,1 unitper30


buildingusers 1
ASD
Bicycle 2 Ifpoint1aboveismetandprovide 2
3
specialchangingroomandbathroomforbicycleusers 1
forevery25bicycleparkinglots.
1 Thepresenceofvegetationlandscapearea(softscape)
whichisfreefromthepark(hardscape)locatedonthe
uppersurfaceofthelandareaofatleast30%ofthe
totallandarea.Theareacalculatedincludeparkabove
thebasement,roofgarden,terracegardenandwall 1
garden.Formationofplantsinaccordancetothe
ASD MinistryofPublicWorksDecreeNo.5/PRT/M/2008of
SiteLandscaping 3
4 greenopenspaceofArticle2.3.1oftheCriteriaforYard
Vegetation.
2 Additionof1pointforeachadditional10%ofsitearea
fortheuseoflandscapingareas. 12

3 Theuseoflocalplantsfromlocalnurserywitha
maximumdistanceof1000kmandproductiveplants. 1

1A Usingmaterialswiththeaveragealbedovalueofat
least0.3accordingtothecalculationofareafor 1
pavementcoveredroof
OR
ASD 1B Usingagreenroofat50%ofroofareawhichisnotused
HeatIslandEffect forelectricalmechanical(ME),calculatedfromthe 2
5 1
broadcanopy.
2 Usingmaterialswiththeaveragealbedovalueofat
least0.3accordingtothecalculationofareafor 1
pavementcoverednonroof.
1A Reducingtheloadvolumeofrainwaterrunofffromthe
landareaintothecitydrainagenetworkby50%ofdaily
1
rainfalltotalvolume,calculatedfromthedischargeof
rainwaterinrainymonths.
ASD StormWater
OR 2
6 Management
1B Reducingtheloadvolumeofrainwaterrunofffromthe
landareaintothecitydrainagenetworkby75%ofdaily
2
rainfalltotalvolume,calculatedfromthedischargeof
rainwaterinrainymonths.
1 HavingandapplyingtheSOPcontrolofcroppestsand
1
weedsusingnontoxicmaterials.
ASD
SiteManagement 2 Provisionofnondomesticatedanimalhabitatatleast 2
7 5%ofthetotalbuildingfootprintareabasedonanimal 1
activityareas(homerange).
1 Improving thequalityof communitylife aroundthe
ASD Building buildingbydoingoneofthefollowingactions:improved
sanitation,provisionofplacesofworship,publictoilets, 1 2
8 Neighbourhood
streetvendorsandcommunitydevelopmenttraining.

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | ii

2 Openingthe pedestrian access to atleast 2 orientations


towardstheneighboringbuildingwithoutpassing 1
throughpublicareas.
3 Dedicatingtothepublicinteresteitherrequiredorupon
consciousnessitselfthatpartofthelandisopentosuch
as:publicutilities(electricitysubstation,ventilationand
MEundergroundstation,etc),supportingthegeneral 1
circulationpath(busbay,laybys,dropoff)ortoprivate
greenopenspace.
4 Revitalizationofculturalheritagebuildings. 1
ENERGYEFFICIENCY&CONSERVATION 36

Theavailabilityofawrittenstatementthatincludesa
commitmentfromtopmanagementwhichcovers:the
P
energyaudit,savingstargetsandspecifictermaction
PolicyandEnergy
plansbytheenergyteam.
P1 Management P
Theavailabilityofacampaignwhichincludesthe
Plan
positiveimpactfromenergysavingswithaminimum
P
installationcampaignispermanentlywrittenonevery
floor,suchassticker,poster,email.
1A Showstheintensityofelectricenergyconsumption
duringthelast6monthstolessthanstandardintensity
ofelectricenergyconsumptionwhichisdeterminedby
P
Minimum GBCIndonesia(250kWh/m2.yearforOffice,450
P2 BuildingEnergy kWh/m2.yearformall,andhotelorapartmentof350 P
Performance kWh/m2.year).
OR
1B Showstheenergysavingsof5%ormoreinthelast6
months. P

1A 4Pointsawardediftheintensityof energy consumption


fromthebuildingshowed5%lessthanthe120%
intensityofelectricenergyconsumptionfromthe
48
standardreferenceinthelast6month.Furthermore,
eachmultiplicationwillgetanadditional1pointwitha
maximumof8points.
1B 9Pointsawardediftheintensityofenergyconsumption
Optimized fromthebuildingshowed3%lessthanthe100%
Efficiency intensityofelectricenergyconsumptionfromthe
EEC1 916 16
BuildingEnergy standardreferenceinthelast6month.Furthermore,
Performance eachmultiplicationwillgetanadditional1pointwitha
maximumof16points.
OR
2 Iftheintensityofenergyconsumptionfromthebuilding
showedmorethan120%intensityofelectricenergy
consumptionfromthestandardreference,thenany 13
decreaseof10%withinthelast6monthswillget1
pointwithamaximumof3points.
Testing, 1A Havedonetherecommissioningorretrokomisioningon
EEC2 Recommissioning MVAC(Mechanicalventilationandairconditioning)(eg 1 2
orRetro chillers)majorequipmentintheperiodayearearlier;

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | iii

commissioning OR
1B Thepresenceofperiodiccontinuouscommissioning
1
withinamaximumof3years.
2 Ifthe points above aremet then thereareadditional
pointsfortesting,recommissioningorretrokomisioning
1
onMVACSystem(AHU,pumps,coolingtower)asa
whole.
EEC31LightingControl 2
1 Conductsaving(Economize)byusingalampwhichhas
20%moreefficientlightingpower,comparedtothe
lightingpowerlistedinthe2003IndonesiaNational 1
Standards(SNI)No61972000onEnergyConservation
inLightingSystems*.
2A Using aminimumof 50%of highfrequencyballasts
1
(electronic)inthegeneralworkspace.
OR
2B Usingaminimumof80%ofhighfrequencyballasts
2
(electronic)inthegeneralworkspace.
*SNIRefertoattachment1
EEC32MechanicalVentilationAirConditioning(MVAC) 10
Efficiencyinequipmentthatusesairconditioning
SystemEnergy systemoperatedwithelectricity,thentheminimum
EEC3 12
Performance efficiencyaccordingtoGBCINDONESIAanditssavings
businessareasfollows:

AC Typeofequipment Minimum 2pointsforevery


System Efficiency savingsefforts*
(kW/TR)
Water Recip/screwchiller 0.881 0.03
cooled Centrifugalchiller 0.656 0.03
Aircooled Recip/screwchiller 1.270 0.05
Unitary Split 1.436 0.02
VRV 1.034 0.03

*foreachsavingseffortswithimprovedefficiency
savingsforeachnumber"savingefforts"whichis
specified,willget2pointswithamaximumof10points

Note:AuthenticationisdonebyanactualSite

PerformanceTest.
1A ProvisionofkWhmeterwhichincludes:
Systemofair,
Systemslightingandsockets, 1
Energy Systemforotherexpenses,
EEC4 Monitoring& Spacewhichisnotexcludedorconditioned 3
Control 1B Thepresence ofmonthlyroutinerecord whichconsistof
resultsfrommonitoringanddatacollectiononthekWh
1
meters.Therecordingismadeduringthelast6months
minimum.

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | iv

1C AppreciatetheuseofenergyintheformofEnergy
Displayplacedinpublicareasbydisplayinginformation
inbargraph;onthecomparisonoftotalenergyuse 1
within12monthsofthepreviousyearwithtotalenergy
usageintheyeartookplaceinyeartodate.
OR
2 Applyingtechnologicalsupportforbuildingequipment
monitoringandcontrolling 3

1 Operationandmaintenancemanualforthewholeair
conditioningsystem(chiller,AirHandlingUnits,cooling 1
tower).
2 Ifpoint1ismet,thenaddedwiththeoperationand
maintenancemanualonaregularbasisforthewhole
Operationand otherequipmentsystems(transportationsystemsin 1
EEC5 3
Maintenance buildings,cleanandsoiled(pump)waterdistribution
systemandpowerbackup.
3 Monthly reports for aminimumof thelast6monthsfor
thebuildingsystemsoperationandmaintenance
1
activities,inaccordancewiththeformatspecifiedinthe
operationandmaintenancemanual.
1 If0.25%ofthemaximumpowerdemandgeneratedby
renewableenergyor2kWpofinstalledrenewable 1
energy*
OR
2 If0.5%ofthemaximumpowerdemandgeneratedby
renewableenergyor5kWpofinstalledrenewable 2
energy*
OR
3 If1,0%ofthemaximumpowerdemandgeneratedby
renewableenergyor10kWpofinstalledrenewable 3
OnSite energy*
EEC6 Renewable OR 5B
Energy 4 If1,5%ofthemaximumpowerdemandgeneratedby
renewableenergyor20kWpofinstalledrenewable 4
energy*
OR
5 If2,0%ofthemaximumpowerdemandgeneratedby
renewableenergyor40kWpofinstalledrenewable 5
energy*
*tomeeteachoftheabovebenchmarks,the
representativeofthebuildingareaskedtochoosea

higherratebetweenthepercentageoramountofkWp
renewableenergyinstalled
CO2EmissionReductionMeasures
1A 0.25%CO reductionfromtheoriginalemission, 1
2
LessEnergy
EEC7 OR 3B
Emission
1B 0.5%CO reductionfromtheoriginalemission, 2
2
OR

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | v

1C 1.0%CO reductionfromtheoriginalemission, 3
2

WATERCONSERVATION 20
Theavailabilityofawrittenstatementthatincludesa
commitmentfromtopmanagementwhichcovers:
P
wateraudit,savingtargetsandspecifictermsaction
Water
plansbywaterconservationteam.
P1 Management P
Theavailabilityofacampaignwhichincludesthe
Policy
positiveimpactfromwaterconservationwitha
P
minimuminstallationcampaignispermanentlywritten
oneveryfloor,suchassticker,poster,email.
Theavailabilityofsubmeterwaterconsumptioninthe
WAC WaterSub
systemofpublicareas,commercialareasandutility 1 1
1 Metering
buildings.
Theavailabilityofstandardoperatingproceduresandits
implementationforthemaintenanceandperiodic
inspectionofplumbingsystemtopreventleakageand 2
Water
WAC wastageofwaterbyshowingthewaterbalanceinthe
Monitoring 2
2 last6monthsforinitialcertification*.
Control
(*)Forthe following certification,reports every6
monthsinthelast3yearsbasedonannualreportsare
required.
Thisassessmentis only for buildings that have
maximumwaterconsumption20%greaterthan
NationalStandard(SNI0370652005onProceduresof
PlumbingSystemImplementation*.

WAC FreshWater 1 Forbuildingswithwaterconsumption20%abovethe


SNI,eachreductionof10%receives1pointtoreachthe 8
3 Efficiency 12
SNIwithamaximumof2points.
2 Ifpoint1isfulfilled,thenanyefforttoreducewater
consumptionby3%fromtheSNIgets1point.Maximum 38
valueis6points.
*SNIRefertoattachment2
Showing thelast6months oflaboratory evidencefor
primarysourcesofwaterinaccordancewiththecriteria
1
ofcleanwateratleastoncewithin6monthsforinitial
WAC certification*.
WaterQuality (*)Forthe following certification,reports every6 1
4
monthsinthelast3yearsbasedonannualreportsare
required.

*RegulationRefertoattachment3
1A Usingrecycledwaterwithsufficientcapacityforthe
needsofmakeupwatercoolingtowers.Benchmark
1
appliesonlytobuildingsthatuseacoolingtoweronthe
WAC refrigerationsystem.
RecycledWater 5
5 OR
1B 100%irrigation needs is notoriginating fromthe
primarywatersourceofthebuilding(LocalWater 1
Enterprise/PDAMandgroundwater).

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | vi

2 Using recycledwater with sufficientcapacityforthe


needsofflushingtoilets,inaccordancewithWHO
2
standardsformediumcontact(<100fecalcoliform/100
ml).
3 Havingawaterrecyclingsystemwheretheoutputis
equivalenttothestandardofcleanwaterinaccordance
totheMinisterofHealthDecreeNo.416/1990ofWater 2
QualityRequirementsandMonitoringtomeetthe
needsofofcleanwater.
Usingafiltrationsystemthatproducesdrinkingwaterin
accordancewithMinisterofHealthDecreeNo.
WAC
PotableWater 492/2010ofDrinkingWaterQualityRequirements* 1 1
6
Minimumineverykitchenorpantry.
*RegulationRefertoattachment4
1A Consumptionofwaterwhichusedeepwellwitha
maximumof20%ofoverallwaterconsumption. 1
WAC DeepWell OR 2
7 Reduction
1B Consumptionofwaterwhichusedeepwellwitha
maximumof10%ofoverallwaterconsumption. 2

1A 50%useoftapwaterinapublicareausingtheauto
stopfeature. 1
WAC WaterTap
OR 2B
8 Efficiency
1B 80%useoftapwaterinapublicareausingtheauto
stopfeature. 2

MATERIALRESOURCESANDCYCLE 12
1A UsingnonCFCrefrigerantandcleanermaterialsthat
haveasmallvalueofOzoneDepletingPotential(ODP), P
<1
OR
Fundamental 1B IfstillusingtheCFCsasarefrigerant,itisnecessaryto
P1 P
Refrigerant conductauditandphaseoutplanfortheuseofCFCsas
refrigerantsinthenext3yearsandreduceconsumption
ofCFCsfromrefrigerationleaksanddamagessetforth P
intheRefrigerantManagementSystemorRMSPlan
Plan.
The availabilityof awrittenstatement that includestop
managementpolicieswhichprioritizeexpenditures/use
forgreenmaterialsinthelistbelow:
a.Regionalproduction
b.CertifiedSNI/ISO/Ecolabel
c.Materialsthatcanberecycled(recycable)
Material d.UsedMaterials(reused)
P2 P
PurchasingPolicy e.Renewablematerial(renewable)
f.Modularorprefabricatedmaterial
g.Certifiedwood
h.Lightsthatdonotcontainmercury
i.Insulationthatdoesnotcontainstyrene
j.Plafondorpartitionthatdoesnotcontainasbestos
k.Compositewoodproductsandlowformaldehyde

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | vii

emissionagrifiber
l.PaintproductsandlowVOCemittingcarpet
Theavailabilityofawrittenstatementthatincludestop
managementpoliciesregulatingwastemanagement
basedonthesegregationbetween:
P
a.Organicwaste,
Waste b.Inorganicwaste,and
P3 Management c.Hazardouswaste P
Policy Theavailability ofacampaignwhichincludesthe
positiveimpactfromwastemanagementbasedonthe
segregationwithaminimuminstallationcampaignis P
permanentlywrittenoneveryfloor,suchassticker,
poster,email.
MRC Usingtheentireairconditioningsystemwithrefrigerant
NonODSUsage 2 2
1 materialsthathaveODP=0(nonCFCandnonHCFC).
Listofenvironmentallyfriendlymaterial:
a.80%ofregionalproductionbasedonthetotal
expenditurestheoverallmaterial
b.30%SNI/ISO/Ecolabelcertified,basedonthetotal
expenditurestheoverallmaterial
c.5%recycledmaterial,basedonthetotalexpenditures
theoverallmaterial
d.10%reusedmaterial,basedonthetotalexpenditures
theoverallmaterial
e.2%RenewableMaterials,basedonthetotal
expenditurestheoverallmaterial
f.30%modularorprefabricatedmaterialsbasedonthe
totalexpenditurestheoverallmaterial
g.100%Woodcertifiedwoodmaterialsbasedontotal
expendituresoverallwoodmaterial
h.2.5%lightsdonotcontainmercury,oftotal
Material expenditureslampunits
MRC i.Insulationthatdoesnotcontainstyrene
Purchasing 3
2 j.Plafondorpartitionthatdoesnotcontainasbestos
Practice
k.Compositewoodproductsandlowformaldehyde
emissionagrifiber
l.LowVOCemittingcarpetandpaintproducts
1A Theavailabilityofdocumentswhichexplainthe
expendituresofmaterialaccordingtothepoliciesinthe
prerequisite2;atleast3ofthematerialspecifiedinthe
1
listofenvironmentallyfriendlymaterialswiththe
purchaseamountasmentionedinthe"purpose"inthe
last6monthsforinitialcertification*.
OR
1B Theavailabilityofdocumentswhichexplainthe
expendituresofmaterialaccordingtothepoliciesinthe
prerequisite2;atleast5ofthematerialspecifiedinthe
2
listofenvironmentallyfriendlymaterialswiththe
purchaseamountasmentionedinthe"purpose"inthe
last6monthsforinitialcertification*.
G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A |
viii

OR
1C Theavailabilityofdocumentswhichexplainthe
expendituresofmaterialaccordingtothepoliciesinthe
prerequisite2;atleast7ofthematerialspecifiedinthe
3
listofenvironmentallyfriendlymaterialswiththe
purchaseamountasmentionedinthe"purpose"inthe
last6monthsforinitialcertification*.
(*)Forthefollowingcertification,reportsevery6
monthsinthelast3yearsbasedonannualreportsare
required.
1 Theavailabilityofstandardoperatingprocedures,
trainingandreportstocollectandsortthewastebased
onorganicandinorganictypes,inthelast6monthfor
1
theinauguralcertification*.

(*)Forthe following certification,reports every6
monthsinthelast3yearsbasedonannualreportsare
required.
2 Iftheorganicandinorganicwastehasbeenseperated,
conductorganicwasteprocessingindependentlyorin
1
cooperationwithofficialagenciesoforganicwaste
treatment.
3 Iftheorganicandinorganicwastehasbeenseperated,
Waste conductinorganicwasteprocessingindependentlyorin
MRC
Management cooperationwithofficialagenciesofinorganicwaste 1 4
3
Practice treatmentwhohasprinciplesof3R(Reduce,Reuse,
Recycle).
4 EffortsofPackagingwastereductionwhicharemadeof
Styrofoamandnonfoodgradeplastic. 1

5 Aneffortfordealingwithwastefromrenovationactivity
toathirdpartyatleast10%fromthethetotal
renovationbudgetinthelast6monthsforinitial
certification*.
1
(*)FortheFollowingcertification,reportsevery6
monthsinthelast3yearsbasedonannualreportsare
required.

1 Theavailabilityofstandardoperatingprocedures,
trainingandmanagementofhazardouswaste
managementsuchas:lamps,batteries,printerinkand 2
MRC HazardousWaste packagingfromcleaningmaterialsinthepast6months
forinitialcertification*. 2
4 Management
(*)Forthefollowingcertification,reportsevery6
monthsinthelast3yearsbasedonannualreportsare
required.
Theavailabilityofstandardoperatingproceduresand
reportforthedistributionofuseditemswhichstillcan
MRC Managementof
berecoveredsuchasfurniture,electronicsandspare 1 1
5 UsedGood
partsthroughdonationsorsecondhandgoodsmarketin
thelast6monthsforinitialcertification*.

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | ix

(*)Forthe following certification,reports every6


monthsinthelast3yearsbasedonannualreportsare
required.
INDOORHEALTHANDCOMFORT 20
Theavailability of awrittenstatement containingthe
commitmentfromtopmanagementtoperformvarious
P
actionstoachievethereductionofsmokingactivity
insidethebuilding.
NoSmoking
P1 Theavailability ofanonsmokingcampaignwhich p
Campaign
includesthenegativeimpactfromthesmokingtous
andtheenvironmentwithaminimuminstallation P
campaignispermanentlywrittenoneveryfloor,such
assticker,poster,email.
Indoorairqualitywhichshowsaminimumintroduction
ofoutsideairbasedonSNINo0365722001of
OutdoorAir
IHC1 ProceduresforVentilationandAirConditioning 2 2
Introduction
SystemsinBuildingsbuilding*.
*SNIrefertoattachment5Aand5B
Smokingisprohibitedinallareasofthebuildingand
doesnotprovidesmokingareawithinthebuilding.If
smokingareasareprovidedoutsidethebuilding,it
Environmental
mustbelocatedminimum5mfromtheentrance,
IHC2 TobaccoSmoke 2 2
wheretheentryoffreshairandwindowopenings;
Control
withafollowupmonitoringprocedures,
documentationandresponsivesystemtowards
smokingprohibition.
1A Forroomswithhighdensity(suchasballroom/
multipurposeroom,publicmeetingrooms,general
office,supermarket)equippedwithgassensors
installationofcarbondioxide(CO2),whichhasa
mechanismtoregulatetheamountofoutsideair 2
ventilationsothattheCO2concentrationinsidethe
roomisnomorethan1,000ppm.Thesensorisplaced
CO2andCO 1.5mabovethefloornearthewaterreturngrille.
IHC3 2
Monitoring OR
1B Forclosedparkingspacesinsidethebuilding,is
equippedwithgassensorsinstallationofcarbon
monoxide(CO)whichhasamechanismtoregulatethe
amountofoutsideairventilationsothatthe 2
concentrationofCOinsidetheroomisnomorethan
23ppm.Thesensorisplaced50cmabovethefloor
neartheexhaustgrille.
Indoorairqualitymeasurementsperformedrandomly,
withthesamplepointsinthemainlobby,workspace
Physicaland oraroomrentedbytenants.Measurementsaretaken

IHC4 Chemical withaminimumof1samplepointper1000m2orthe 6
Pollutants maximumnumberofsamplesis25pointforasingle
building.
Sumberpencemarudaradariluarruangan:

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | x

1 Ifthemeasurementresultsforindoorairqualitymeets
thestandardsofpollutantgasesinTable1:

Table1.GasPollutionfortheOfficeWorkplace

No Parameter MaximumConcentration
mg/m3 ppm
1 SulfideAcid (H2S) 1
2 Ammonia(NH3) 17
3 Carbonmonoxide 8
(CO)
4 Nitrogen 5.6 3
dioxide(NO2)
5 Sulfurdioxide(SO2) 5.2 2
Source:MinisterofHealthDecreeNo1405/Menkes/SK/XI/2002of
EnvironmentalHealthStandardsintheOfficeandIndustrialWork.
(AnnexI,Chapter3,A.3.Pollutiongases)GovernorofJakarta
RegulationNo.54/2008ofIndoorAirQualityStandards
2
2 ConcentrationofTotalDustisbasedon Ministerof
HealthDecreeNo1405/Menkes/SK/XI/2002of
1
EnvironmentalHealthStandardsintheOfficeand
IndustrialWork.(AnnexI,Chapter3,A.2.TotalDust)*.
Indoorairpollutionsources:
3 ConcentrationVolatileOrganicCompound(VOC)is
basedonSNI1902322005ofThresholdLimitValues 1
forChemicalSubstancesinWorkplaceAir*.
4 Ifpoints1,2and3aremet;andtheconcentrationof
formaldehydeinaccordancewithSNI1902322005*. 1

5 Ifpoints1,2and3aremet;andtheconcentrationof
asbestosinaccordancewithMinisterofHealthDecree 1
No.1405/Menkes/SK/XI/2002*.
*SNIandRegulationrefertoattachment6.
1 Cleaningfilters,coolingcoilandVAC(ventilationand
airconditioning)toolsinaccordancewiththeschedule
ofregularmaintenancetopreventtheformationof
1
moldandfungusasthegrowingplacefor
microorganisms.Schedulemaintenanceisbasedonthe
standardfactoryguidelines.
Biological
IHC5 2 Takemeasurementsfornumberofbacterias,witha 3
Pollutant
maximumamountofbacteriacolonyof700/m3air
andfreeofpathogenicgermsintheroomwhichis
determinedbyGBCINDONESIA(basedonMinisterof 2
HealthDecreeNo1405/Menkes/SK/XI/2002of
EnvironmentalHealthStandardsintheOfficeand
IndustrialWork)
Themeasurementresultsshowtheleveloflighting
(illumination)ineveryworkspaceinaccordancewith
IHC6 VisualComfort theSNINo0361972000ofEnergyConservationin 1 1
LightingSystems*.
*SNIrefertoattachment7

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | xi

Themeasurementresults show thesoundlevelin


workspaceinaccordancewiththeSNINo036386
2000ofSpecificationforSoundLevelandTimeofhum
forBuildingandHousing(RecommendedDesign
Criteria)*.
Measurementsaretakenrandomly,asmanyasfive
IHC7 AcousticLevel pointsaminimumeveryonespacepertwofloors. 1 1
Soundleveldependsonthetypeofoccupancy.
Measurementsaretakenwhenitisunoccupiedandin
aconditionofbuildingequipment(suchasventilation
systems,elevators,plumbingandlightingsystem)is
operating.
*SNIrefertoattachment8
1 Conductbuildingusercomfortsurveyswhichinclude
airtemperature,lightinglevels,soundcomfort,and
1
buildinghygienepestcontrol.Minimumrespondents
are30%fromthetotalusersofthebuilding.
2A Meetpoint1,andiftheresultsofthesurveystated
that60%ofthetotalrespondentsarecomfortable. 1

BuildingUser OR
IHC8 3
Survey 2B Meetpoint1,andiftheresultsofthesurveystated
that80%ofthetotalrespondentsarecomfortable. 2

3 Ifpoint1ismet,andtheresultsofthefirstsurvey
claimedlessthan60%ofrespondentsarecomfortable,
butdofollowtheimprovementsandthenconducta 1
secondsurveywhichresultatleast80%oftotal
respondentsarecomfortable.
BUILDINGENVIRONMENTMANAGEMENT 13
Thepresenceofoperation&maintenanceplanwhich
supportsthegoalfortheachievementofGREENSHIP
EBrating,whichfocusedon:mechanical&electrical
systems,plumbingsystemsandwaterquality,exterior
Operation&
&interiormaintenance,purchasingandwaste
P1 Maintenance P P
management
Policy
Includes:
Organizationalstructure,StandardOperating
Proceduresandtraining,workprograms,budgets,
periodicreportsatleastevery3months.
1 Applicationofinnovationwiththebuildingquality
improvementquantitatively,forexample:ASD4,EEC
1,WAC3,andIHC4sothereisanincreasein 12
efficiencywhichexceedsthelimitsetintherelevant
BEM
Innovations rating. 5
1
2 Applicationofinnovationwiththemanagement
approach,suchasbehaviourchangesencouragement,
13
forexamplesinASDASD2and8andMRC2,3and4,
resultinginincreasedefficiencyinotherratings.

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A | xii

1 Availabilityof Design Intent document andOwner's


Project,alsofollowingthechangeswhichoccurred 1
duringtheperiodofrevitalizationandoperational.
2 Availabilityof As Built Drawing (aminimumofsingle
DesignIntent&
BEM linedrawings)document,technicalspecificationsand
Owner'sProject 2
2 manualsforoperationandmaintenanceofequipment
Requirement
(generators,transportationinbuildings,air 1
conditionersandcoolingtowers),alsofollowingthe
changeswhichoccurredduringtheperiodof
revitalizationandoperational.
1 Thepresenceofanintegratedstructureinsidethe
operationalstructureofthebuildingthatisincharge
GreenOperational 1
BEM ofmaintainingtheapplicationofsustainability/green
&Maintenance buildingprinciples. 2
3
Team
2 AminimumofoneGreenshipProfessionalsinvolvedin
operational&maintenancewhoworksfulltime 1

1A Forcommercialbuildings:aLeaseAgreementcontains
clausesthattheTenantwillmeetaminimumof1
2
criteriainGREENSHIPEBforeachcategoryofASD,
EEC,WAC,IHCandtheMRC.
BEM Green
OR 2
4 Occupancy/Lease
1B Forbuildingswhichisusedpersonally,has theSOPand
Trainingwhichincludestheeffortstomeetthese
2
criteriainGREENSHIPEBwithaminimumof1ratingin
eachcategoryofASD,EEC,WAC,IHCandtheMRC.
1 Theavailabilityofminimumperiodicscheduleevery6
monthsandtrainingprogramsintheoperationand
maintenanceforsite,energy,water,materialsand 1
Operationand HSES(HealthSafetyEnvironmentalandSecurity).
BEM
Maintenance 2
5 2 Evidenceofoperation andmaintenance training
Training
implementationforsite,energy,water,materialsand
1
programsalongwithevaluationfromtheHSES
training.
TOTAL 117

G R E E N S H I P E x i s t i n g B u i l d i n g V e r s i o n 1 . 0 G B C I N D O N E S I A |
xiii