You are on page 1of 4

XARTU / 1 - LDVI/ V2

CHARACTERISTICS
Mul-run conguraons available when using the transductor or XDI
Vercal low-drag index. Simple and bidireconal interface. The XARTU/1-LDVI package is determined depending on the
versions available.
0 8 5 0 3 0

applicaon or the communicaon requirements desired:

API Compable API Chapter 21. Telephone, cellular, radio or satellite communicaon.

Ample availability of pressure ranges (Absolute or Suitable Backup baery depending on the applicaon and
Calibrated). communicaon opon chosen.

Can be packaged with a solar panel of 1 Wa and a 1.2


Planum RTD of 100 Ohms. Ah baery.

0/1 Digital outputs for corrected or uncorrected volumes. Availability for compabe applicaon with coriolis
and Ultrasonics.

How does it work?


Based on the XARTU/1 SBC61 electronic card which has been the heart of the products line of the EAGLE
XA/1 series. Optionally, a low-drag index (LDVI) provides the user with an economically mechanic support
for the electronic device. The volume corrector (VC - LDVI) includes an internal pressure transductor and an
RTD (Resistance Temperature Detector), an external display and a 2400 bps modem in the standard produc-
tion line. The VC-LDVI is compatible with all the internal processes which include the calculation of AGA7,
AGA 8 (Detalied and Thick 1 and 2) and AGA 3. Additional funcionalities allow a greater communication
capacity with ports for the reading of different gas analyzers and allow for correction of values in real time.

The VC-LDVI is a fully funcional flow computer able to make calls by exception, alarm or at predetermined
intervals to Scada centrals, control and monitor the state of the valves, communicate with the centrals
through an infinity of simultaneous communication systems such as cenventional Radio, Trunking, CDPD,
Cellemetry, Satellite, Microburst, Telephone, and others, using proprietary protocol or Modbus.

Can manage different communication systems in Hot Stand By in case of principal system failure. Multiple
analogous inputs and output allow it to monitor additional pressures, temperature, presence of gas sensors,
intrusion detection, etc. Even make corrections to two volumes with independent pulses, pressure and tem-
perature. Eagle Research has been serving the needs and requeriments of the Natural Gas Industry during
the last 25 years with a high range of products.
Technical Specicaons

FUNCTION DESCRIPTION
7-30 VDC. Two baery inputs with MTA connectors. A terminal block type input for energy supply/recharge-
Energy
able baery. A terminal block for solar panel.

Energy Opons Alkaline baery 9Vdc.

Batera de Back Up 3.6Vdc Lithium: 10 year backup for database and historic informaon.

Processor Phillips P51XAS3 16 bit high performance at 22.1184 MHz.

Memory 512 Kx8 remotely programmable of type FLASH 512.x8 RAM with energy supplied through backup
baery. Stores daily and hourly history during 40 days of the basic parameters. It is possible to increase
the capacity to more than 90 days depending on the requirements.

Real Time Clock


Sustained with backup baery, controlled by crystal at +/-1sec/day of accuracy.

Internal Inputs DC Voltage, ambient temperature.

Pulse Inputs Four pulse inputs programmable for soware for form A or C; high or low speed.

Digital Inputs/ Five mulpurpose digital I/O with high funconality such as: pulse inputs and PWM outputs. Two digital
Outputs I/O need an OPTO module for their operaon, and the other three can be used in Form C or A, as outputs
for (solid state relays, maximum 100mA for AC or DC) or state inputs (50V mac., only DC).

Six analogous inputs of general purpose with 12 bit resoluon, analog sampling, and soware calibra-
Analogous Inputs
on. Rated input of 0-5Vdc or when placing a 250 Ohm resistance it can be used as an input of 4-20 mA.

Temperature Inputs Two inputs for RTD with 12 bit resoluon; three compensated shielding ground wires.

A MODEM port with OH detecon. Speed up to 2400 bauds. Two RS-232 ports with RX, TX, RTS, CTS, and
Communicaons
port start or change in protocol signal. Speed congurable up to 115,200 baud. Direct connecon inter-
face with radios, modems, etc. With MTA or terminal block connector. Supports dierent types of proto-
cols by port such as HexAscii, Modbus, Teledyne/GeoTech and Valmet.

State LED A programmable LED to indicate the dierent states.

By installing the electronic elements, it is possible to expand its capacity which would allow to monitor 6
Expansion Capacity
total pressures (or 5 pressures and the odorant level, etc.), low pulse inputs or high frequency of two addi-
onal meters, telephone modem, second RS232 communicaon port. Digital inputs to monitor the state
of the actuators, valves, etc. Digital outputs to control the injecon or control the valves and actuators,
with addional accessories it is possible to monitor a high quanty of pressures, temperatures and 6 addi-
onal RS232 communicaon ports.

Guaranty Four years in all the components fabricated by Eagle Research.

CHARACTERISTICS OF TRANSDUCERS/SENSORS.
Pressure Transducer Accuracy: +_-0.25%FS including all the external eect from 20YF a +140YF. Available ranges 0-1 PSIG,
0-5 PSIG, 0-10PSIG, 0-25PSIG, 0-60PSIG, 0-100PSIG, 0-200PSIG, 0-300PSIG, 0-500PSIG, and 1000PSIG.
Other ranges by order.
Pressure Sensor 2 - 12 bit inputs at 3-wire, precision of +1yf.
Wireless Technologies USA - Witech USA Corp
20283 STATE ROAD 7, SUITE 400
BOCA RATON, FL. 33498
PHONE: (561) 883-8130 - FAX: (561) 883-8129
www.witechusa.com

2013 Wireless Technologies USA - Witech USA corp All rights reserved. The contents of this publicaon are presented for
informaonal purposes only. While every eort has been made to ensure informaonal accuracy, they are not be construed
as warranes or guarantees, express or implied, regarding the products or services described herein or their use or applicabi-
lity. Witech USA reserves the right to modify or improve the designs or specicaons of such products at any me without
noce. All sales are governed by Witech USA terms and condions which are available upon request. Witech USA does not
assume responsibility for the selecon, use or maintenance of any product. Responsibility for proper selecon, use and
maintenance of any Witech product remains solely with the purchaser and end-user.