Professional Documents
Culture Documents
MIL-STD-1553
June 2017
3.3V Monolithic Dual Transceivers
39 VDDA
38 VDDA
43 BUSA
42 BUSA
41 BUSA
40 BUSA
37 TXA
36 TXA
44 N/C
35 N/C
34 N/C
transceivers designed to meet the requirements of the
MIL-STD-1553 specification.
N/C 1 33 N/C
The transmitter section of each bus takes complementary RXENA 2 1573PCI 32 N/C
CMOS / TTL Manchester II bi-phase data and converts it to GNDA 3 1573PCT 31 TXINHA
GNDA 4 30 RXA
differential voltages suitable for driving the bus isolation GNDA 5 1573PCM 29 RXA
transformer. Separate transmitter inhibit control signals VDDB 6
VDDB 7
28 N/C
27 N/C
are provided for each transmitter. BUSB 8
1574PCI 26 TXB
BUSB 9 1574PCT 25 TXB
BUSB 10 1574PCM 24 TXINHB
The receiver section of the each bus converts the 1553 bus BUSB 11 23 N/C
bi-phase differential data to complementary CMOS / TTL
data suitable for input to a Manchester decoder. Each
N/C 12
N/C 13
N/C 14
N/C 15
RXENB 16
GNDB 17
GNDB 18
GNDB 19
RXB 20
RXB 21
N/C 22
receiver has a separate enable input, which forces the
receiver outputs to logic "0" (HI-1573) or logic 1 (HI-
1574).
44 Pin Plastic 7mm x 7mm
To minimize the package size for this function, the Chip-scale package (QFN)
transmitter outputs are internally connected to the receiver
inputs, so that only two pins are required for connection to VDDA 1 20 TXA
each coupling transformer. For designs requiring
BUSA 2 1573PSI 19 TXA
independent access to transmitter and receiver 1553
BUSA 3 1573PST 18 TXINHA
signals, please contact your Holt Sales representative.
RXENA 4 1573PSM 17 RXA
GNDA 5 16 RXA
VDDB 6 15 TXB
1574PSI
FEATURES BUSB 7
1574PST 14 TXB
BUSA 2
20 TXA
19 TXA
44- pin plastic chip-scale package (QFN)
1573CDI
! Less than 0.5W maximum power dissipation
BUSA 3 18 TXINHA
1573CDT
RXENA 4 17 RXA
1573CDM
VDDB 6
1574CDI
16 RXA
15 TXB
package options 1574CDT
BUSB 7 1574CDM 14 TXB
GNDB 10 11 RXB
PIN DESCRIPTIONS
PIN
(DIP & SOIC) SYMBOL FUNCTION DESCRIPTION
FUNCTIONAL DESCRIPTION
The HI-1573 family of data bus transceivers contains differ- The receivers differential input stage drives a filter and
ential voltage source drivers and differential receivers. They threshold comparator that produces CMOS data at the
are intended for applications using a MIL-STD-1553 A/B RXA/B and RXA/B output pins. When the MIL-STD-1553
data bus. The device produces a trapezoidal output wave- bus is idle and RXENA or RXENB are high, RXA/B will be
form during transmission. logic 0 on HI-1573 and logic 1 on HI-1574.
TRANSMITTER The receiver outputs are forced to the bus idle state (logic "0
on HI-1573 or logic 1 on HI-1574) when RXENA or RXENB
Data input to the devices transmitter section is from the com- is low.
plementary CMOS inputs TXA/B and TXA/B. The transmit-
ter accepts Manchester II bi-phase data and converts it to dif- MIL-STD-1553 BUS INTERFACE
ferential voltages on BUSA/B and BUSA/B. The transceiver
outputs are either direct- or transformer-coupled to the MIL- A direct-coupled interface (see Figure 2) uses a 1:2.5 ratio
STD-1553 data bus. Both coupling methods produce a nomi- isolation transformer and two 55 ohm isolation resistors
nal voltage on the bus of 7.5 volts peak to peak. between the transformer and the bus. The primary center-
tap of the isolation transformer must be connected to GND.
The transmitter is automatically inhibited and placed in the
high impedance state when both TXA/B and TXA/B are In a transformer-coupled interface (see Figure 2), the
driven with the same logic state. A logic 1 applied to the transceiver is connected to a 1:1.79 isolation transformer
TXINHA/B input will force the transmitter to the high imped- which in turn is connected to a 1:1.4 coupling transformer.
ance state, regardless of the state of TXA/B and TXA/B. The transformer-coupled method also requires two coupling
resistors equal to 75% of the bus characteristic impedence
RECEIVER (Zo) between the coupling transformer and the bus.
The receiver accepts bi-phase differential data from the MIL- Figure 3 and Figure 4 show test circuits for measuring
STD-1553 bus through the same direct- or transformer- electrical characteristics of both direct- and transformer-
coupled interface as the transmitter. coupled interfaces respectively. (See electrical
characteristics on the following pages).
RECEIVER
RXA/B
Receive Input
Logic Filter
RXA/B
RXENA/B Comparator
TXA/B
TXA/B
BUSA/B - BUSA/B
Vin
(Line to Line)
RXA/B (HI-1573)
tRG tRG
RXA/B (HI-1573)
RXA/B (HI-1574)
tRG tRG
RXA/B (HI-1574)
DC ELECTRICAL CHARACTERISTICS
VDD = 3.3 V, GND = 0V, TA = Operating Temperature Range (unless otherwise specified).
AC ELECTRICAL CHARACTERISTICS
VDD = 3.3 V, GND = 0V, TA =Operating Temperature Range (unless otherwise specified).
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
RECEIVER (Measured at Point AT in Figure 4)
Receiver Delay tDR From input zero crossing to RXA/B or RXA/B 500 ns
Note 3
Receiver gap time tRG Spacing between RXA/B and RXA/B pulses 60 430 ns
Note 1 Note 2
Receiver Enable Delay tREN From RXENA/B rising or falling edge to
40 ns
RXA/B or RXA/B
TRANSMITTER (Measured at Point AD in Figure 3)
Driver Delay tDT TXA/B, TXA/B to BUSA/B, BUSA/B 150 ns
Rise time tr 35 ohm load 100 300 ns
Fall Time tf 35 ohm load 100 300 ns
Inhibit Delay tDI-H Inhibited output 100 ns
tDI-L Active output 150 ns
Note 1. Measured using a 1 MHz sinusoid, 20 V peak to peak, line to line at point AT (Guaranteed but not tested).
Note 2. Measured using a 1 MHz sinusoid, 860 mV peak to peak, line to line at point AT (100% tested).
Note 3. Measured using a 1 MHz sinusoid, 860 mV peak to peak, line to line at point AT. Measured from input zero crossing point.
MIL-STD-1553
BUS A
(Direct Coupled)
Isolation
Transformer 55W
BUS A
Transceiver A MIL-STD-1553
55W BUS A BUS B
(Transformer Coupled)
1:2.5
MIL-STD-1553
Stub Coupler
Isolation
Transformer BUS B 52.5W
Transceiver B
BUS B 52.5W
1:1.79 1:1.4
HI-1573 / HI-1574
VDD
Each Bus
Isolation
Transformer 55W BUS A/B
TXA/B
TXA/B MIL-STD-1553 35W
RXA/B Transceiver 55W BUS A/B
RXA/B
1:2.5
GND
Figure 3. Direct Coupled Test Circuit
VDD
Each Bus
Isolation
Transformer
TXA/B BUS A/B
TXA/B MIL-STD-1553 70W
RXA/B Transceiver
BUS A/B
RXA/B
1:1.79
GND
Figure 4. Transformer Coupled Test Circuit
HEAT SINK - ESOIC & CHIP-SCALE The heat sink is electrically isolated and may be soldered to
PACKAGE any convenient power or ground plane.
THERMAL CHARACTERISTICS
JUNCTION TEMPERATURE
PART NUMBER PACKAGE STYLE CONDITION JA
TA=25C TA=85C TA=125C
Heat sink
HI-1573PSI / T / M 20-pin Thermally 54C/W 52C 112C 152C
unsoldered
enhanced plastic SOIC
(ESOIC) Heat sink
HI-1574PSI / T / M 47C/W 49C 109C 149C
soldered
HI-1573CDI / T / M 20-pin Ceramic
Socketed 62C/W 56C 116C 156C
HI-1574CDI / T / M side-brazed DIP
HI-1573PCI / T / M 44-pin Plastic chip- Heat sink
49C/W 50C 110C 150C
HI-1574PCI / T / M scale package (QFN) unsoldered
ORDERING INFORMATION
HI - 157x xx x x (Plastic)
PART PACKAGE
NUMBER DESCRIPTION
Blank Tin / Lead (Sn / Pb) Solder
F 100% Matte Tin (Pb-free RoHS compliant)
PART PACKAGE
NUMBER DESCRIPTION
PC 44 PIN PLASTIC CHIP-SCALE PACKAGE QFN (44PCS)
PS 20 PIN PLASTIC ESOIC, Thermally Enhanced Wide SOIC w/Heat Sink (20HWE)
HI - 157xCD x (Ceramic)
PART TEMPERATURE BURN LEAD
NUMBER RANGE FLOW IN FINISH
I -40C TO +85C I No Gold (Pb-free, RoHS compliant)
T -55C TO +125C T No Gold (Pb-free, RoHS compliant)
M -55C TO +125C M Yes Tin / Lead (Sn / Pb) Solder
RECOMMENDED TRANSFORMERS
The HI-1573 and HI-1574 transceivers have been transformers. Holt recommends the Premier Magnetics
characterized for compliance with the electrical require- parts as offering the best combination of electrical
ments of MIL-STD-1553 when used with the following performance, low cost and small footprint.
REVISION HISTORY
0.215 0.115
(0.008 0.005) 7.495 0.385
12.80 (0.295 0.015)
BSC
(0.504)
See Detail A
0.419 0.109
(0.016 0.004)
Electrically isolated heat
2.181 0.131 sink pad on bottom of
(0.086 0.005) package
Connect to any ground or
power plane for optimum
1.27 0 to 8 thermal dissipation
BSC 0.200 0.100
(0.50) (0.008 0.004)
0.835 0.435
(0.033 0.017)
BSC = Basic Spacing between Centers Detail A
is theoretical true position dimension and
has no tolerance. (JEDEC Standard 95)
1.000 .010
(25.400 .254)
.310 .010
(7.874 .254)
.050 TYP.
(1.270 TYP.)
.300 .010
.200 .085 .009 (7.620 .254)
(5.080)
max (2.159 .229)
0.50 BSC
(0.0197)
0.400 0.050
1.00 Electrically isolated heat (0.016 0.002)
max 0.200 typ sink pad on bottom of
(0.039)
(0.008) package
Connect to any ground or
power plane for optimum
BSC = Basic Spacing between Centers thermal dissipation
is theoretical true position dimension and
has no tolerance. (JEDEC Standard 95)