PROPOSED PACKAGE CAPACITY: 2.

0 MW (2500KVA)
AGN Technology offers the full and complete 2.0 MW of electricity package as a turnkey solution. The enter
package shall be install and test for client by AGN Technology engineering department.

Package Price for 2.8MW Synchronized Electricity: $1.545m**

Package Price for Grid Connected 2.0 MW Synchronized Electricity: Call For Details Price
**Note: Synchronized 5 generator (Diesel Engine) and through power to one common bas-bar.

Payment Terms:
60% advance along with at the time of contract singing, Balance 30% payment after delivery materials to site
and remaining 10% will be payment at the time of project handover to the client.

Payment Terms for War Zone Countries:


80% advance along with at the time of contract singing, Balance 20% will be payment after delivery
materials to the site.

Civil Construction and Site Preparation:


Project related all civil construction and site preparation is the fully client responsibility.

Material Transportation:
Inside UAE:
Transport all material from AGN Technology warehouse (in UAE) to site location is including with package
price.

Outside UAE:
Transport all material from AGN Technology warehouse (in UAE) to site location is the client responsibility.

Security and AGN Technical Staff Accommodations:


Inside UAE:
A security and AGN technical staff accommodations in UAE is the AGN Technology responsibility.

Outside UAE and War Zone Countries:


Security, Accommodation and Transportations of all AGN technical staff are the sole responsibility of the
client in the war zone countries. It can be discussed in full details once the contract is signed between AGN &
its clients.

Price Change:
All Price are subject to change and alternation without prior notice. Should the prices changes during the
contract, AGN will not change price for existing client contract.

Contract Cancelation Terms:


Once the contract is signed and fully discussed in details, the payment /deposit is for failed and non-
refundable at any circumstance. Delay of payment shall be the same as the cancelation of the project the
time both party agree up on.
LIST OF MATERIALS FOR PROPOSED PACKAGE

S/N Description of materials Quantity Required Remarks


1 Cummins Diesel Engine Generators 5x500=2500KVA
Capacity: 500KVA, 400 Volt & 50Hz
2 Synchronization Control Panel 5 Nos with common
Model: ATSP09 Bus-bar
3 MCCB 5 Nos
Capacity: 1000Amps, 3 pole
Brand: ABB/Schneider
4 Air Circuit Breaker (ACB) 1 No
Capacity:4000 Amps, 3 pole
Brand: ABB/ Schneider
5 Low Voltage Power Cable As per required
Voltage: 400 V
Cable size: 630mm or 400mm
Single core, Copper conductor
Insulation: XLPE
6 Grounding Cable As per required
Size: 95mm, Y/G copper Conductor
7 Grounding Cable As per required
Size: 35mm, Y/G copper Conductor
8 Grounding Cable As per required
Size: 16mm, Y/G copper Conductor
9 Control Cable As per required
10 External Fuel Tank 1 No
Capacity: 10K gallons
11 Fuel Pipes As per required
12 Fuel Filter 5 No
13 Accessories
Options For The Above Package
14 Step-up Power Transformer 1 No As per client
(0.4KV/33KV or 0.4KV/11KV or as per client requirements) demand
Capacity: 2500 KVA, 50Hz
15 SF6 RMU or SF6 Breaker or VCB 1 No As per client
Capacity: 630 Amps with all protection system demand
16 High Voltage or Medium Voltage Power Cable As per required As per client
Cable size: 300mm, Three core, Copper conductor demand
Insulation: XLPE, Armored steel ware insulated
17 20 Container 5 No As per client
demand
Civil constrictions are the client responsibility; AGN should
be to quote, If requested by client.
SINGLE LINE DIAGRAM FOR 2 MW SYNCHRONIZED ELECTRICITY

Sf6 RMU
TO LOAD TO LOAD Capacity: 630A
CT Ratio: 100:1
With Over current &
Earth fault protection

Vacuum Circuit Breaker (VCB)


S1
P1 Capacity: 630A
CT Ratio: 100:1
250A/5A/1A
CT s S2 With Over current &
P2
Earth fault protection

Step-up Power Transformer


0.4KV/20KV or 0.4KV/11KV or
0.4KV/33KV(2500KVA) YNd11

Air Circuit Breaker (ACB)


Capacity: 4000A
CT Ratio: 4000/1A/5A
With all metering & protection

4000A/5A
CT
Computerized Synchronization
Control Panel

Computerized
Synchronization MCCB 1000A,4P,50KA
control panel 1000/5A WITH SCC, OC PROTECTION
WITH MOTOR OPERATOR
1000/1A
CT CT CT CT 1000/5A
GEN- 1

GEN- 2

GEN- 5
G EN- 3

GEN- 4

Cummins Diesel Generator


Capacity: 500kVA, 400V, 50Hz

Copyright 1998-2009 agnenegy.com


Please note: All logos, trade marks and any other wording or pictures are used for illustration anddisplay purposes only.
MATERIAL DESCRIPTIONS AND DETAIL TECHNICAL SPECIFICATIONS

Generator Technical Specification

1500 rpm (50 Hz Ratings):


Gross Engine Output Net Engine Output Typical Generator Set Output
Stand by Prime Base Stand by Prime Base Stand by (ESP) Prime (PRP) Base (COP)
KWm/BHP KWm/BHP KWe KVA KWe KVA KWe KVA
500/670 444/595 317/425 477/639 426/571 299/400 440 550 400 500 281 351

Weight & Dimensions:


Length Width Height Weight(dry)
mm mm mm Kg
2269 1332 1669 1658
Fuel Consumption 1500 (50 Hz):
% KWm BPH L/ph US
gal/ph
Standby Power 100 500 670 123.0 32.4
100 444 595 103.0 27.3
Prime Power 75 333 447 78.7 20.8
50 222 298 54.7 14.5
25 111 149 30.0 8
Continues Power 100 317 425 75.7 20 Standby Power
Standby power is defined as the
Engine Specification maximum power available during a
variable electrical power sequence,
Design 4 cycle, in-line, Turbo Charged, Air-cooled under the stated operating conditions,
Bore 137 mm (5.39 in.) for which a
Stroke 169 mm (6.65 in.) generating set is capable of delivering in
Displacement 15 liter (912.3) the event of a utility power outage or
Cylinder Block Cast iron, 6 cylinders under test conditions for up to
500 hours of operation per year under
Battery Capacity 100A/hr
average of 70% load. Overloading is not
Battery Charging Alternator35 amps
permissible.
Starting Voltage 24 volt, negative ground
Fuel System Direct injection
Prime Power
Fuel Filter Spin on full flow filter Prime power is defined as being the
Air Cleaner Type Dry replaceable element with restriction indicator maximum power which a generating set
Lube Oil Filter Spin on fuel filters with water separator is capable of delivering continuously
Type(s) whilst supplying a variable electrical
Standard Cooling 122 F (50 C) ambient radiator load. Average load should be 70%. The
System generator can be overloaded 10% for 1
hour per 12 hours.
Alternator Specification
Design Brushless single Revolving field
bearing
Stator 2/3 pitch
Rotor Single bearing Flexible disc
Insulation System Class H
Standard Temperature 125 - 163 C Stand by
Rise
Exciter Type Self Excited
Phase Rotation A (U), B (V), C (W)
Alternator Cooling Direct drive centrifugal blower fan
AC Waveform Total No load: 1.5%
Harmonic Distortion None distorting balanced linear load: 5%

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
SYNCHRONIZATION CONTROL PANEL SPECIFICATION

ATSP09 SYNCHRONIZATION CONTROL PANEL SPECIFICATIONS

LOAD PROPERTIES:
Automatic and manual synchronization
Can synchronized until 10 generators among
them selves and feed the workload
Load sharing at generators according to power
Automatically start and stop according to load
Automatically balancing work hours (co-aging)

COMMUNICATION PROPERTIES:
Communication over (AQ) bus-bar with
electronic engine control units (optional)
Alarm message with SMS (optional)
Open communication over RS 232 or RS 485 interface
Support Motbus RTU protocol (concordant with scada system)

INDICATOR PROPERTIES:
LCD text indicator
All engine and alternator parameters can be watched
Engine and alternator protection
Keep the records of generator alarms, last 25 records
Expansion modules (in and out)

With LCD screen in ATSP09 synchronization panels you can measure the following rates and with the stated protection,
system reliability put in first place.

MEASUREMENTS:

DIRECT MEASURES:
Oil pressure
Coolant temperature
Fuel level (optional)
Oil temperature (optional)
Accumulator voltage
Engine circulation
Generator frequency
Generator phase-neutral voltage
Generator inter-phase voltage
Generator phase current
Generator earth current (optional)
Generator phase sequence

EXPANDABLE MEASUREMENTS:
Generator total active power (KW)
Generator total visible power (KVA)
Generator total reactive power (KVAr)
Generator average power factor (cos)
HIDDEN MEASUREMENTS:
Actual time
Left time for the next (maintenance)
Generator positive KWh
Generator negative KWh
Generator KVAh
Generator KVArh
Number of starter
Maximum positive vector slide
Maximum negative vector slide

PROTECTION SYSTEM:

ENGINE PROTECTION:
Low oil pressure
High coolant water temperature
High oil temperature (optional)
Low/high frequency cycle
Battery charger rectifier error
Low/high accumulator voltage
Low/high fuel level (optional)

ALTERNATOR PROTECTION:
Low/high voltage
Low/high frequency
Extreme voltage
Earthling error (optional)
Reverse power
Wrong phase rotation of alternator
Excitation loss

CIRCUIT BREAKER PROTECTION:


Generator switching off error
Generator switching on error

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
MCCB TECHNICAL SPECIFICATION

Brand Name ABB


Capacity 1000Amps
P Pole Three
Frequency 50Hz
Design Compact
Serial number 034798
NS 100N
Vi 750
Uimp 8KV
Icu 50
(V) 380/415~KA 50
Vc-389/240 440~50
500/525 ~ 40
690 ~ 30
660 Ics 75% Icu
Icw 25 KA/.5s Cat-B
Generator switching off error
Generator switching on error
Protection system Over load

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
AIR CIRCUIT BREAKER SPECIFICATION

Brand name ABB


Model E4S/f
Rated uninterrupted current (at 40 C) Iu [A] 4000
Number of poles 4
Rated service voltage Ue [V ~] 690
Rated ultimate short-circuit breaking capacity Icu
220/230/380/400/415 V ~ [kA] 80
440 V ~ [kA] 80
500/660/690 V ~ [kA] 75
Rated short-time withstand current Icw 80
(1s) [kA] 75
(3s) [kA]
Rated short-circuit making capacity (peak value) Icm [kA] 176
Application category (in accordance with IEC 60947-2) B
Isolation behavior (in accordance with IEC 60947-2)

Fixed: H = 418 mm - D = 302 mm L [mm] 746


Withdraw able: H = 461 - D = 396.5 mm L [mm] 774
Overall Dimensions Weights (circuit-breaker complete with releases and CT, not including accessories)
Fixed [kg] 120 Withdraw able (including fixed part) [kg] 170 250

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
STEP- UP POWER TRANSFORMER SPECIFICATION

Capacity of power transformer 2500kVA


1 Duty Continuous to suit Max. Ambient
50C
2 Type Oil immersed Conservator type
3 Cooling ONAN
4 Primary Voltage 0.4KV
5 Secondary Voltage 33kV or 20KV or 11 KV or as per
client demand
6 Frequency 50 Hz
7 No. of phase 3
8 Winding Cu wound
9 Vector Group YNd11
10 Primary Connection Delta
11 Secondary Connection Star
12 Tapping 7.5% in steps of 2.5%
13 Insulation class of winding Class A
14 Temperature rise Deg. C
Top oil 50 C
Winding 55 .C
15 % Impedance 7.5% +IEC TOL.
16 No load losses 4.5 KW + IEC TOL.
17 HV termination Side mounted cable box
18 LV termination Side mounted cable box
19 Applicable Standards IEC 60076
20 Over all dimension 1350*1500*1500 mm
21 Total Weight 7312 KG
22 Accessories Terminal marking plates
Tap Switch (Off- load)
Rating Plate
Cooling fan/Radiators
2 Nos earthling terminals
Lifting lugs
Oil level gauge
Drain valve
Top filling hole & plug
Thermometer with max. pointer
Pressure relief device
OTI, WTI, Bucholz Relay

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
SF6 RMU TECHNICAL DETAILS
2 nos of 630Amp triple pole, single break, 3- position (ON, OFF and
EARTH) ring main switches, each with independent manually charged
spring mechanism and fully rated earth switch with provision for earth
and test of the cable.
2 nos of air insulated cable boxes and cable clams suitable for a 3 core
cable up to 300mm.
1 no 250 Amps triple pole, vacuum circuit breaker, with independent
manually charged spring mechanism and fully rated earth switch with
provision for earth and test of the cable.
1 no air insulated cable box and clamp suitable for a 3- core cable up to
185mm.
1 no mimic diagram on front panel, complete with status indicator.
1 set of positive standard mechanical interlocks.
1 set of current transformer for relay protection.
1 no ABEVA make self powered relay type: MICOM P124 for O/C & E/F
protection.
1 no 24V DC shunt trip coil for remote tripping of circuit breaker.
1 set of fully interlocked test access cover.
2 nos of neon indicator lamps /phase comparator sockets for each ring
switch.
1 no stud for earthling connection.
1 no pressure indicator and SF6 recharging facility.
1 no PULL TO TRIP mechanism (Suitable shrouded).
1 set of auxiliary terminal.
1 no operating handle.
1 no earth fault indicator, electrical Auto reset (240V AC), complete with
solid core current transformer.

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
VACUUM CIRCUIT BREAKER (VCB) TECHNICAL SPECIFICATIONS

DESCRRIPTION UNIT SPECIFICATION


Rated voltage KV 20
Service voltage KV 20
Rated frequency HZ 50
Rated insulation level (one KV rms 28
min. 50Hz withstand voltage)
Impulse withstand voltage KV peak 75
(1.2/50 micro-sec. wave) KV
peak
3 second withstand current KA rms 20
Peak withstand current KA peak 63
Internal arc withstand KA rms 25
current (IEC 60298 app. A)
(1 second)
Bus-bar rated current A 630
Auxiliary voltage
for spring loading 220V 50HZ
For protective relays, control, 24V 50 HZ
signaling
For heating 220V 50HZ
Current transformer (CT) 3 150/5A(for metering) and
No. ring type (Multiple CT) 150/1A(for protection)
Potential Transformer (PT) 2 20/0.4KV (Class0.5,50 VA)
No.
Earth fault relay
Over Current relay for 3
phase (RED, YELLOW,
BLUE)
Protection system Master trip relay (VAJ
relay)
Trip current supervision
relay

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
LOW VOLTAGE CABLE TECHNICAL DETAILS

1 Cable Type Low voltage cable


2 Size of cable(Core*Area in 1*630
mm)
3 Applicable Standard IEC60502
4 Suitable of earthed/Unearthed Earthed/unearthed
system system
5 Voltage grade (KV) KV 0.6/1 KV
6 Maximum rated conductor C 105 C
temperature
7 Max. Allowed conductor C 250 C
temperature during short
current
8 Continuous current carrying
capacity when Load In
In Air 745
In Ground 1050
In Duct 1050
9 Conductor
Material Annelid copper
Shape Standard circular
conductor
Cross section area 630
10 Insulation
Materials XLPE compound, as per
ISO7098
Normal thickness of insulation mm 2.00
11 Outer Sheath
Materials PVC
Extruded or Wrapped Extruded
Thickness of sheath (Min.) mm 2.10
Color of sheath Black
12 Overall diameter of cable mm 37.0
13 Approx. Net Weight of cable Kg/K 3869.0
m
14 Overall quantity tolerance % 5%
15 Recommended minimum mm 740
bending radius
16 Max. DC resistance at 20C Ohm 0.047
/Km
17 Max. AC resistance at 70C Ohm
/Km

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
FUEL TANK DESIGN SPECIFICATION

Capacity 10,000 Gallons


Shape Cylindrical
Thickness 8mm
Port Inlet, Outlet (For Overflow)
Bottom stand 1000mm Ht.
Material Grade A-36, Mild Steel
The fuel tank shall be light in color to
minimize heating of the fuel by radiant
Painting System heat sources. Any plating or paint materials
shall not be degraded by contact with the
fuel
Fuel drain (The fuel drain assembly shall be
constructed at the bottom side of the fuel
tank)
Accessories Fuel Gauge
Man hole
Air Vent
Ladder
Walking Platform at the top

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE
standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without
notice and all information given is subject to the AGN Technology current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

You might also like