Professional Documents
Culture Documents
M. S. SAMORA a
mssamora@terra.com.br
A. C. DOS SANTOS a
acds@feciv.ufu.br
L. M. TRAUTWEIN b
leandromt@gmail.com
M. G. MARQUES c
mariliagmarques@outlook.com
Abstract
There are many theories and empirical formulas for estimating the shear strength of reinforced concrete structures without transverse reinforcement.
The security factor of any reinforced concrete structure, against a possible collapse, is that it does not depend on the tensile strength of the concrete
and the formation of any collapse is ductile, thus giving advance warning. The cracking from tensile stress can cause breakage of the concrete and
should be avoided at all cost, with the intent that any such breakage does not incur any type of failure within the structure. In the present research
study, experiments were performed in order to analyze the complementary mechanisms of the shear strength of lattice beams of reinforced concrete
frames without transverse reinforcement. The experimental program entails the testing of eight frames that were subjected to a simple bending pro-
cess. Two concrete resistance classes for analyzing compressive strength were considered on the construction of frames, 20 MPa and 40 MPa . To
resist the bending stresses, the beams of the frames are designed in domain 3 of the ultimate limit states. Different rates and diameters of longitudinal
reinforcement were used, 1.32% and 1.55% with 12.5 mm diameter and 16.0 mm in longitudinal tensile reinforcement. From the obtained results,
an analysis was made of the criteria already proposed for defining the norms pertinent to the portion of relevant contribution for the shear resistance
mechanisms of concrete without the use of transverse reinforcement and the influence of the concrete resistance and longitudinal reinforcement rates
established in the experimental numerical results.
Resumo
H muitas teorias e frmulas empricas que estimam a resistncia ao cisalhamento de estruturas de concreto armado sem armadura transversal.
A segurana de qualquer estrutura de concreto armado, em relao a um possvel colapso, que ela no dependa da resistncia a trao do
concreto, assim, o colapso de forma dctil, com aviso prvio. A fissurao, proveniente de esforos de trao, pode causar a ruptura do con-
creto e deve ser evitada para que no ocorra nenhum tipo de falha na estrutura. Nesta pesquisa foram realizados experimentos para analisar os
mecanismos complementares ao de trelia de resistncia ao cisalhamento em vigas de prticos de concreto armado sem armadura transversal.
O programa experimental consistiu no ensaio de oito prticos e os modelos foram submetidos flexo simples. Foram consideradas duas classes
de resistncias compresso do concreto para a concretagem dos modelos, 20 MPa e 40 MPa. Para resistir os esforos de flexo, as vigas foram
dimensionadas no domnio 3 do estado limite ltimo. Foram usadas duas taxas de armadura, 1,32% e 1,55% com dimetros de 12,5 mm e 16,0
mm de armaduras longitudinais de trao. A partir dos resultados obtidos foram analisados os critrios j propostos por normas para definir a
parcela da contribuio relativa aos mecanismos resistentes de cisalhamento do concreto sem o uso de armadura transversal e a influncia das
resistncias do concreto e taxas de armadura longitudinal nos resultados numricos obtidos experimentalmente.
a
Universidade Federal de Uberlndia (UFU), Uberlndia, MG, Brasil;
b
Departamento de Estruturas da FEC Unicamp, Campinas, SP, Brasil;
c
Universidade Federal de Viosa (UFV), Viosa, MG, Brasil.
Received: 19 Nov 2015 Accepted: 16 May 2016 Available Online: 06 Feb 2017
2017 IBRACON
Experimental analysis of the concrete contribution to shear strength beams without shear reinforcement
Figura 1
Analogia de trelia proposta por Ritter e Morsch [5]
O dimensionamento de peas de concreto armado baseia-
Vc = 0,29 l
'
f c bw d (8) -se na teoria do campo da compresso modificada com o n-
gulo das bielas de compresso = 35. A norma Canaden-
Onde: se CSA A23. 3-04 [16] na seo 11.3.4 determina o valor da
w Taxa de armadura longitudinal;
Figura 2
Detalhe da seo transversal para clculo de Sz, adaptado de [15]
resistncia do concreto ao cisalhamento de acordo com Sze , que permite o tamanho do agregado e valor equivalente
a equao: considerado a S z e depende das caractersticas da armadu-
Vc = fc l b
'
f c bw d v (11) ra longitudinal, onde:
35 S z
Onde:
c = 00,65
,65 Fator de resistncia do concreto;
S ze =
15 + ag (13)
= Fator responsvel pela resistncia do concreto fissurado,
= 0,21 ag = Dimetro mximo nominal do agregado;
= 1,0 = Densidade de concreto normal;
bw = Largura da viga em (mm); S ze 0,85S z
d v = Altura til de cisalhamento em (mm). S z Deve ser tomado como d v ou a distncia mxima entre as
A resistncia compresso do concreto deve ser menor ou igual linhas de distribuio da armadura longitudinal, o que for menor.
a 64 MPa ou Cada linha de camada da armadura longitudinal deve ter uma rea
'
f c 8MPa , 0,9d d v 0,72h e bw 250mm pelo menos de 0,003 bw S z conforme ilustra a Figura 2.
'
f c em MPa , bw , d v em mm, Vc em ( N ) 2.6 FIB MODEL CODE 2010
O clculo de para seo transversal sem armadura de cisalha-
mento pelo mtodo simplificado dado por: A resistncia ao cisalhamento para peas de concreto sem arma-
a) Se a seo no contm armadura transversal e o tamanho dura de cisalhamento, de acordo com o FIB Model Code 2010 [18]
mximo nominal do agregado no inferior a 20 mm deve pode ser calculada com a equao:
ser tomado como:
230 f ck
b =
(1000 + d v ) (12) VRd ,c = k v bw z (14)
gc
b) Se a seo no contm armadura transversal, o valor de Onde:
pode ser determinado para todos os tamanhos de agregados z = Altura til em (mm);
substituindo o parmetro d v da equao pelo parmetro bw = Espessura da viga em (mm);
Figura 3
Diagrama de carregamento e esforos
Tabela 1
Identificao dos modelos
Armadura
Srie Tipo Modelo fc (MPa) longitudinal Asl (cm2) l (%) a/d
de trao
a
P1 A 4 12,5mm 4,90 1,32 2,83
b
20
a
P2 B 3 16,0mm 6,03 1,55 2,67
b
a
P3 A 4 12,5mm 4,90 1,32 2,83
b
40
a
P4 B 3 16,0mm 6,03 1,55 2,67
b
Figura 4
Dimenses dos prticos cotas em cm
Figura 5
Detalhamento dos prticos, tipos A e B cotas em cm
Tabela 2
Resultados dos ensaios de resistncia compresso do concreto dos prticos
Idade (C) fc (20 MPA) fcm (MPA) fc (40 MPA) fcm (MPA)
8,90 23,24
fc, 7 dias 8,92 22,61
8,94 21,29
12,7 27,72
fc, 14 dias 12,26 28,95
11,82 30,18
17,65 35,87
fc, 28 dias 17,13 36,72
16,62 37,57
21,36 41,05
fc, 56 dias 21,61 40,50
21,86 39,95
Tabela 3
Resultados dos ensaios de mdulo de elasticidade e resistncia trao
fct = 0,9 fct, sup
Concreto Idade (C) fcm (MPA) Ec (GPA) fct, sup (MPA)
(MPA)
fc (20 MPa) 56 dias 21,54 28,79 2,45 2,21
fc (40 MPa) 56 dias 44,13 36,30 3,98 3,58
Tabela 4
Idade dos corpos de prova
Srie Tipo Modelo fc (MPa) Data de concretagem Data do ensaio Idade(dias)
a 07/08/2014 125
P1 A
b 11/07/2014 98
20
a 18/07/2014 105
P2 B
b 04/07/2014 91
04/04/2014
a 16/06/2014 73
P3 A
b 24/07/2014 111
40
a 27/06/2014 84
P4 B
b 01/08/2014 119
Tabela 5
Resistncia compresso provvel estimada para o concreto
Resistncia
Srie Tipo Modelo fc, 28 dias (MPa) fc, 56 dias (MPa) Idade(dias)
provvel estimada
a 125 19,54
P1 A
b 98 19,24
17,13 21,60
a 105 19,33
P2 B
b 91 19,15
a 73 40,39
P3 A
b 111 41,59
36,72 40,50
a 84 40,81
P4 B
b 119 41,76
Figura 6
Posio geral dos extensmetros no prtico
de carga constituda por um cilindro de ao instrumentado com A carga foi aplicada com incrementos de 15 kN. Em cada estgio
extensmetros eltricos de resistncia calibrado at 500 kN, con- de carregamento, foram efetuadas observaes e registrado por
forme ilustra a Figura 7. vdeo o panorama de fissuraes ocorridas no prtico. medida
Figura 7
Vista geral e detalhe do ponto de aplicao da carga
Figura 8
Panorama de fissurao dos prticos e cargas de ruptura
Tabela 7
Valores das resistncias de acordo com as normas
Vc (kN)
Prticos ABNT NBR EN 1992-1-1- CSA A 23.3-04
ACI 318-14 (8) BS 8110-97 FIB CODE 2004
6118:2014 2004 ag = 20mm
P1-A-a
49,22 50,04 36,29 20,63
P1-A-b
66,30 25,31
P2-B-a
52,11 52,97 39,95 21,61
P2-B-b
P3-A-a
79,74 68,52 42,64 28,25
P3-A-b
107,40 34,67
P4-B-a
84,41 72,53 46,90 29,59
P4-B-b
Tabela 8
Comparao dos valores calculados e experimentais
Valores calculados Valores experimentais
Prticos F Vu,exp / Vu,cal
Vu,cal (kN) Mu,cal (kN m) =Vu (kN) Mu,exp (kN m)
2
P1-A-a 65,40 25,00 0,435
150,30 57,34
P1-A-b 70,20 26,80 0,467
P2-B-a 57,93 22,10 0,316
189,60 69,89
P2-B-b 59,92 22,90 0,327
P3-A-a 105,66 40,30 0,623
169,50 64,68
P3-A-b 96,98 37,00 0,572
P4-B-a 83,11 31,70 0,397
210,00 80,32
P4-B-b
Observao: Os resultados do prtico P4-B-b foram retirados por no obter valores aleatoriamente distribudos em torno de um valor mdio e no
seguir uma tendncia das amostras
que se aumentava o carregamento foi possvel observar a evolu- por mecanismos complementares definidos pelas normas ABNT
o das fissuras que eram marcadas com giz de cera na superfcie NBR 6118:2014 [2], ACI 318-14 [14], BS 8110-97 [15], EN 1992-1-
do concreto, Figura 8. Com o uso de extensmetros eltricos liga- 1-2004 [17], CSA A23. 3-04 [16] e FIB MODEL CODE 2004 [18],
dos ao equipamento aquisitor de dados, foram medidas as defor- Tabela 7.
maes das armaduras e do concreto. Com a armadura longitudinal proposta, o valor terico do momen-
to ltimo para escoamento da armadura longitudinal foi calculado
4. Resultados e discusses conforme as hipteses da ABNT NBR 6118:2014 [2] admitindo-se
a distribuio retangular de tenses de compresso no concreto. A
Foram calculados os valores da parcela de fora cortante resistida este momento fletor corresponde uma fora cortante ltima obtida
com o uso do programa Ftool [20]. A Tabela 8 apresenta os re-
sultados comparativos do valor terico com o valor experimental.
Tabela 9
Variao da resistncia dos mecanismos Vu ,exp
A comparao , dos resultados experimentais em relao
complementares em funo da resistncia Vu ,calc
compresso do concreto
aos valores da fora cortante ltima obtida dos valores calcula-
F dos, nos mostra que os prticos com maior taxa de armadura
Prticos =Vu (kN) (%)
2 l = 1,5 % (P2 e P4) apresentaram relao menor ao com-
parar com a relao dos prticos com menor taxa de armadura
21,60 MPa 1,32% 67,80
49,44 l = 11,32
,32 %% (P1 e P3).
40,50 MPa 1,32% 101,32 Na Tabela 9 apresenta-se o resultado da variao da resistn-
21,60 MPa 1,55% 58,93 cia ao cisalhamento dos mecanismos complementares mantidas
41,03 constantes porcentagem de armadura longitudinal em funo da
40,50 MPa 1,55% 83,11 resistncia compresso do concreto.
Figura 9 Figura 10
Variao da taxa de armadura longitudinal/ Variao da taxa de armadura longitudinal/
resistncia a compresso do concreto 21,6 MPa resistncia a compresso do concreto 40,5 MPa
Observa-se que para as vigas dos prticos sem armadura trans- para o momento fletor, extensmetro L0, Figura 11, observa-se
versal analisadas, com a mesma taxa de armadura longitudinal, que as armaduras no chegaram ao escoamento mximo admiti-
houve um aumento na resistncia ao cisalhamento dos mecanis- do por norma 10 mm/m. O maior valor obtido foi de 0,0013 mm/m
mos complementares ao de trelia, com o acrscimo da resistn- para a viga P1-A-a, confirmando a ruptura das vigas por cisalha-
cia compresso do concreto. mento e no a flexo simples.
Na Figura 9 e Figura 10, apresenta a comparao da carga resis- A Tabela 8 mostra os resultados da comparao dos valores expe-
tente das vigas com a mesma resistncia compresso do con- rimentais da parcela resistente do concreto ao cisalhamento sem
creto, variando a taxa de armadura. Constata-se que as vigas que armadura transversal (Vu ,exp ) em relao aos valores de (Vc ) cal-
possuem menor taxa de armadura para uma mesma resistncia a culados pelas normas [2, 14, 15, 16, 17,18].
compresso do concreto, suportaram maiores cargas. Pode-se verificar que h uma grande variao dos valores calcu-
Ao analisar as deformaes das vigas na posio de maior valor lados pelas normas comparados com os valores experimentais.
Figura 11
Deformao na armadura longitudinal (L0) para os pilares da srie P1-A e P2-B
Tabela 10
Comparao entre valores experimentais e calculados das normas
Vu,exp / Vc
Prticos CSA A23.3.04 FIB CODE
ABNT NBR 6118:2014 ACI 318-14 (8) BS 8110-97 EN 1992-1-1:2004
ag=20mm 2014
P1-A-a 1,328 1,307 1,802 0,986 3,170 2,584
P1-A-b 1,426 1,403 1,934 1,059 3,403 2,774
P2-B-a 1,112 1,094 1,450 0,874 2,681 2,289
P2-B-b 1,149 1,131 1,500 0,904 2,773 2,368
P3-A-a 1,325 1,542 2,469 0,984 3,740 3,048
P3-A-b 1,216 1,415 2,274 0,903 3,433 2,797
P4-B-a 0,985 1,146 1,772 0,774 2,809 2,390
P4-B-b
Vu,exp / Vc 1,216 1,307 1,802 0,904 3,170 2,584
A ABNT NBR 6118:2014 e o ACI 318-14 so as que mais se con- 6. Referncias bibliogrficas
vergem os valores calculados com diferena aproximada de 10%,
Tabela 10. [1] FUSCO, Pricles Brasiliense. Estruturas de concreto: Solicita-
es Tangenciais. So Paulo: Editora Pini Ltda., 2008. 328 p.
5. Concluses [2] ASSOCIAO BRASILEIRA DE NORMAS TCNICAS.
NBR 6118:2014. Projeto de estruturas de concreto Proce-
Este trabalho objetivou-se apresentar as anlises dos resultados
dimento. Rio de Janeiro, 2014.
experimentais sobre a parcela de fora cortante Vc , em vigas dos
[3] Ritter W. Die bauweise hennebique. Schweizerische Bauzei-
prticos engastados, com a variao da resistncia caracterstica
tung 1899;33:4161.
do concreto e taxa de armadura longitudinal. Conclui-se que:
[4] ASCE-ACI Committee 445 on Shear and Torsion. Recent
1) Com a menor taxa de armadura longitudinal, mantidas cons-
approaches to shear design of structural concrete. ASCE, J
tantes as resistncias caractersticas do concreto, houve
Struct Eng 1998;124(12):1375417.
um aumento da resistncia dos mecanismos complemen-
[5] K. De Wilder, P. Lava, D. Debruyne, Y. Wang, G. De Roe-
tares ao de trelia frente ao cisalhamento. Com base nas
ck, L. Vandewalle. Experimental investigation on the shear
tenses de trao e compresso aplicadas ao concreto por
capacity of prestressed concrete beams using digital image
uma barra de ao sob ao de uma fora a ser transferida
correlation.
pelo efeito de pino, a mxima fora transferida pelo efeito de
[6] ACI Committee 318. 318-11: Building code requirements for
pino foi afetado negativamente com o aumento do dimetro
structural concrete and commentary. ACI; 2011. p. 503. [3]
das barras;
2) Com o aumento da resistncia caracterstica do concreto CEN European Committee for Standardization.
compresso, mantidas constantes as taxas de armadura lon- [7] Eurocode 2. Design of concrete structures general rules
gitudinal da viga, os resultados experimentais mostraram um and rules for buildings. EN 1992-1-1, Brussels, Belgium;
aumento da resistncia dos mecanismos complementares ao 2004. p. 225.
de trelia frente ao cisalhamento, evidenciando assim maior [8] M. Fernndez Ruiz, A. Muttoni, J. Sagaseta. Shear streng-
mobilizao pelo engrenamento dos agregados. th of concrete members without transverse reinforcement:
3) Em relao aos valores obtidos experimentalmente compara- A mechanical approach to consistently account for size and
dos aos valores de clculo das normas, os resultados que mais strain effects. Engineering Structures, Volume 99 (2015)
se aproximaram dos experimentais so do EUROCODE: 2004; 360372.
4) Os valores fixados da norma ABNT NBR 6118: 2014 so me- [9] WALRAVEN, Joost Cornelis.AGGREGATE INTERLOCK:
nores em aproximadamente 21,6% com relao aos valores A theoretical and experimental analysis.1980. 202 f. Tese
obtidos experimentalmente das resistncias do concreto ao ci- Doutorado - Curso de Engenharia Civil, Delft University Of
salhamento. A frmula de clculo da parcela de fora cortante Technology, Holanda do Sul, 1980.
resistida por mecanismos complementares ao modelo de treli- [10] KIM, Jin-keun; PARK, Yon-dong. Prediction of Shear Streng-
a Vc = 0,6 f ctd bw d na flexo simples o fator multiplicador th of Reinforced Concrete Beams without Web Reinforce-
dos termos da equao poderia ser igual a 0,7296 a conside- ment.ACI Materials Journal,Estados Unidos, v. 93, n. 3,
rar os resultados dessa pesquisa. p.213-222, maio 1996.