INTRODUCTION
Evan Multi specialty Hospital and Research
Centre is being set up by enterprising team of
doctors in Muzaffarnagar on a well located plot in
the central part of the city. It is envisaged to have
State of the art facilities in the proposed hospital
having all the facilities of multi-specialty and
research Centre.

Muzaffarnagar is a city and a


municipal board in the Indian State of
Uttar Pradesh.The city was established
in Mughal period by a Sayyid Jagirdar,
Munawar Lashkar Ali, and so named in
honour of his father, Muzaffar Ali Khan.
It is a major steel and sugar
manufacturing hub of northern India[].
Many popular farmer leaders come
from Muzaffarnagar,Late Prime Minister
of India Chaudhary Charan Singh
belongs from Muzaffarnagar.

It is situated midway on Delhi and Dehradun National Highway (NH 58), the city is
also well connected with the national railway network.
THE SITE AND ITS LOCATION

The site is a trapezoidal shape of land having 2053.76 Sq.mt area with roads on its side.
The front of the plot abutting a main road on South, connecting old Delhi road to bypass
road, and the side of the plot touching the colony road on East.

The location also appears in the google map showing the predominantly residential area
in the vicinity but with mixed land use on the main road.

SATELLITE VIEW OF SITE


ROAD NETWORK NEAR SITE
BUILDING REGULATIONS AND BYE-LAWS

The plot of land being part developing area in Muzaffarnagar, the following building
regulations and bye-laws shall prevail:

(a)Permissible FAR = 250

(b)Max Ground Coverage = 30%

(c)Additional Coverage possible = 10%

(d)Set backs = 7 mts for a height of 21 mts

(e)The set back provided = 6 mts on both side and the rear,9

mts on front side.

(g)Basement = for the parking and services

(h) No of floors = 7 floors i.e. (G+6 floors)

(i) Terrace to have some accommodation with temporary sheet roofing.


FACILITIES PROVIDED

S.NO BEDS S.NO FACILITIES

A. BEDS B. OPD REQUIREMENT


PROVIDED
MEDICINE
ICU (MEDICAL & 15 BEDS CARDIOLOGY
SURGICAL)
ORTHOPAEDICS
ICCU 10 BEDS
SURGERY
POST OP 6 BEDS
GYNAECOLOGIST
DIALYSIS UNIT 4 BEDS CHEST & TB PHYSICIAN
POST CATH 4 BEDS NEUROLOGIST & NEURO
SURGERY

POST 4 BEDS CARDIOLOGY&CARDIAC


DELIVERY SURGERY
(GYNAE) NEPHROLOGY &
PAEDIATRIC
PICU 4 BEDS
ENT & EYE
EMERGENCY 6 BEDS
S.NO SPACES
DAY CARE 4 BEDS
WATER STORAGE
PRIVATE 20 BEDS
TANKS
(ATT.TOILET)
TWIN SHARING 20 BEDS
(ATT.TOILET) SOLAR WATER
HEATING
GENERAL 12 BEDS
(ATT.TOILET) FIRE FIGHTING

SUITE 2 NOS. REGISTRATION/PAYM


(ATT.TOILET) ENT COUNTER

TOTAL 111 BEDS WAITING LOBBY


S.NO FACILITIES S.NO FACILITIES

E. REQUIREMENTS
C. OTS REQUIREMENT
MEDICINE STORE
SURGERY GENERAL STORE

ORTHOPAEDICS HOSPITAL KITCHEN &


LAUNDRY
GYNAE
CANTEEN ( GENERAL &
DOCTOR)
NEURO / CARDIAC
CONFERENCE ROOM
MOT WITH
EMERGENCY MORTUARY
PLASTER ROOM(FOR F. ADMINISTRATIVE
ORTHO) REQUIREMENTS

D. DIAGNOSTICS DIRECTORS ROOM (ATT


REQUIREMENTS TOILET)

PATHALOGY LAB ACCOUNTS & CLERICAL


STAFF ROOM
BLOOD BBANK
MANAGER ROOM
RADIOLOGY ATTACH TOILET
X RAY RECORD ROOM / STORE
ULTRA SOUND G. OTHER SPACES /
CT/MRI FACILITY

TRAEDEMILL/ECHO PARKING IN BASEMENT

ECG SPACE FOR DG SETS

SLEEP STUDY ROOM SPACE FOR MGPS

PHYSIOTHERAPY SPACE FOR ELECTRIC


UNIT(RAHAB) CONTROL ROOM

CATH LAB LIFTS & STAIRCASE


DESIGN CONCEPT

The proposed Evan Hospital having a


minimum 100 beds requirements and all
other facilities has been planned in such
a way that the efficiency of planning
remains the maximum with total
utilization of every inch of space.

The building is conceived as an iconic


structure with latest eco-friendly material
and finishes which will eventually qualify
for GRIHA 4/5 star rating to establish a
land mark in the field of health care
buildings in an around the
Muzaffarnagar.
.

SYSTEMS ADOPTED
The planning concept is focused
towards having the activities put up in
different floors in a hierarchical
manner by means of keeping higher
traffic centric activities being placed
in the lower levels / floors and the
once having lesser movement are
placed in upper floors.

PHOTOVOLTAIC SOLAR
PANEL ON TERRACE

The ground floor of the building is essentially kept for the patients reception, registration
and help desk which will facilitate the patients interface with the Doctors and Staff on duty to
further direct a patient towards OPD, Diagnostics or some other area of the hospital as the
case may be.
Besides there are souvenir shop, medical
shop, cafeteria and a well equipped
medical emergency set up having 10
bedded ward, Nurses and Doctors on duty
and related facilities. In addition to this
there are two general hospital elevators
and a staircase besides one service
elevator and a fire escape staircase,
strategically located to confirm to the fire
code requirements.

The lift core will have a faade of the Italian


marble and polished granite. The flooring
of public areas shall have granite including
the staircase. The indoor areas will have
the false ceiling of health grade metal false
ceiling.

Basement has provision of a few services


and the parking with Mechanical
ventilation. The basements have direct
connectivity to the upper floors of the
building by means of stairs and lift. Out of
the two lifts provided only one lift shall be
taken to the basement while the other one
shall start from Ground Floor and move
upwards.

Main Entrance on the ground has a


Helpdesk / Reception and waiting area
for the visitors as there shall be Access
Control System for the visitors in order to
better regulate the outsiders movement.

The lift lobby and the stairs are suitably located to effectively save the space for other
functions.
In todays context with growing pace of development
and eminent shortfall between demand and supply of
energy we need to design our buildings to be self
sustainable through massive passive energy systems
such as Solar Panels/ Photo Voltaic.

One of the most


important sources
of energy i.e. the
solar energy can
be collected by
means of solar
energy panels
installed on the
roof terrace of the
building which
can be taken into
account at the
time of design
and the energy
thus retained can
be used in getting
the hot water
supply, cooking
and emergency SSG. ENVISION
lighting etc.
SOLAR GLASS
SOLAR GLASS
Fashioned out of superior
A Solar Glass is a combination of technology, SGG Envision SKN
solar and glass technologies is an advanced Fifth Generation
glass windows coated with a low solar and Thermal Insulation
admittance (low e) coating block glass for Energy Efficient Glazing.
radiant heat transfer this lowers Manufactured by deposition of
the amount of heat that passes specialized metallic oxides, SGG
through a glass .solar glass is Envision SKN is created by using
often used to lower energy costs a magnetically enhanced, Nano -
This empowers SGG ENVISION technology based cathodic
SKN with unique features to sputtering process and is the
enhance interior daylight by high most energy efficient glass in its
light transmission with class & long wave radiation
tremendous control over short (U-Value) which makes it ideally
wave radiation (Solar Factor) suited for Green Buildings.
Heres to a greener planet.
SGG ENVISION SKN is available in
3660mm x 2550mm; 3660mm x
2440mm; 3210mm x 2250mm
dimensions, in 6, 8 and 10mm
thicknesses (12mm available on
request) allowing for large-sized
high-specification units.

ENVISION
EXTRAORDINARY
APPLICATIONS
The superior SGG Envision SKN is best
suited for commercial buildings which
include extensive glazing requirements.

SGG Envision SKN not only conforms


to the exacting norms of Green Building
(LEED) / TERI GRIHA, but also
surpasses the laid down standards. It is
the ideal glazing solution for energy
efficient sustainable green building
design requirements for every season.

SSG INVISION SOLAR GLASS

One of the most important sources


of energy i.e. the solar energy can
be collected by means of solar
energy panels installed on the roof
terrace of the building which can be
taken into account at the time of
design and the energy thus retained
can be used in getting the hot water
supply, cooking and emergency
lighting etc.
WATER AND WASTE
WATER MANAGEMENT
Efficient Water Usage
Reduce landscape water requirement
Reduce building water use
Efficient water use during construction

Recycle, Recharge, and Reuse of Waste-water


Waste-water treatment
Water recycle and reuse (including rainwater)

Rain water harvesting system & storage system


Recharge the surplus water (after reuse) in to
aquifer
RECHARGE PIT

RAIN WATER
HARVESTING
PATH FINDING
Way finding is an environmental design
discipline, it must provide a strategic benefit to
the business of running a hospital in order to be
perceived as having value.

Destination terminology in health-care design


often utilizes numbering, lettering, and symbol
hierarchies to a great extent, along wit d
estimation names. The integration of the various
identification methodologies is crucial to a
workable system.

Universal design approaches Health-care facilities are used by a


large number of people with handicaps, both visual and physical, and
by people with a low proficiency in the national language.

WAY FINDING

3
HOSPITAL PLANNING

1st Floor shall have 14 Nos consultation


chambers to cover all the specialties
including an orthopedic consultation
chamber with plaster room. There are two
pockets of waiting area in the consultation
zone besides there is diagnostic having
pathology, ultrasound, ECG, ECO /
Trademill, Blood bank, X-ray and CT, MRI.
1st Floor shall have 14 Nos consultation
chambers to cover all the specialties
including an orthopedic consultation
chamber with plaster room. There are two
pockets of waiting area in the consultation
zone besides there is diagnostic having
pathology, ultrasound, ECG, ECO /
Trademill, Blood bank, X-ray and CT, MRI.
Second and Third floors are planned as a
typical floor with a combination of Private
wards 12 Nos and General wards 24
beds along with a visitors room near the
lift lobby and Nurses duty room, treatment
room and doctors room.
Fourth floor shall have 12 private
wards along with visitors room,
sleep study room, physiotherapy
unit, conference room, accounts

and clerical staff, manager room


and a Directors office.

Fifth floor hhe provision of


Dialysis Unit along with Dialysis
beds along with visitors room,
Doctors Lounge and canteen
besides ICU of 10 beds and
ICCU of 12 beds.

Sixth Floor being the top functional floor has the


operation theatres (4 Nos) out which 2 shall be
modular OTs along with sterilization, scrub store
and OT store. Before the sterile zone of OTs there
is a semi sterile zone and a change room, nurses
duty room and nurses station.

In the vicinity are the post operative wards, PICU,


post labour, preparation / pre-OT and visitors room
besides a Cath lab and Post Cath. The height of
this floor shall be 3.9 mt floor to floor.
CONCEPTS IN
HOSPITAL PLANNING

Healing healthcare environment

Patient focused designed


Adaptability of ever changing demand
Universal patient room

Digital hospital

HORIZONTAL & VERTICAL


MOVEMENT
CONNECTED BY CORRIDOR AND
LIFT/STAIRCASE

Corridors are distinguished using


different material finishes and
colors
Trying to create a stress free &
welcoming entry
Color coordinated, easy signages
for way finding
ANGULAR VIEW
AERIAL VIEW
SITE PLAN
BASEMENT FLOOR PLAN
GROUND FLOOR PLAN
ACCOMODATION
IN ALL FLOORS

Different Floors Having


Different Colors To
Identify The Floors &
Department

Third & second floor


having same colour
Second and third
floors are planned as a
typical floor with a
combination of private
wards 12 nos. and
general wards 24 beds
along with a visitors
room

The top floor i.e. 7th cum terrace floor


has two major activities of mechanical
laundry and hospital kitchen housed in
structure of temporary sheet roofing.
This floor is also connected by a service
lift to all the floors. The remaining area
shall be open for other installations such
as solar water heater, photovoltaic cell
panels and overhead water tank etc.
TEMPORARY SHEET ROOFING

PHOTOVALTAIC CELLS
HOSPITAL SERVICES:
MECHANICAL LAUNDARY
WASHER EXTRACTOR

TUMBLER DRYER

IRONER

VACUUM FINISHING TABLE

SUPPLY & INSTALLATION OF DRY LINEN TROLLEY

SUPPLY & INSTALLATION OF WASH ROOM

TROLLEY
FLAT BED PRESS

SUPPLY & INSTALLATION OF SHELF

TROLLEY

SUPPLY & INSTALLATION OF MOBILE

TABLE

SUPPLY & INSTALLATION OF AIR

COMPRESSOR

SUPPLY & INSTALLATION OF STEAM

BOILER (PHE-25)

WASHING MATTRESS
IRONING TABLE
MACHINE STERILISER
FLOW DIAGRAM : MECHANICAL LAUNDARY
HOSPITAL SERVICES: KITCHEN

COOKING AREA

FOUR BURNER COOKING RANGE CHAPATTI ROLLING TABLE


SIDE TABLE
CHAPATTI PLATE WITH PUFFER
WORK TABLE WITH SINK
CHAPATTI DUMPING TABLE
EXHAUST HOOD WITH S.S FILTER &
CFL LIGHTING SYSTEM WORK TABLE
SHALLOW FRYER
JUICER MACHINE-ALL S.S
RICE BOILER
WATER BOILER- ELECTRIC OPERATED
RICE PREPARATION TABLE
RICE STRAINER-DOUBLE TANK MILK BOILER - ELECTRIC OPERATED
WORK TABLE WITH ONE UNDER
DOUGH MIXER
SHELF
WORK TABLE WITH SINK HEAVY DUTY ATTA

COLD ROOM HOT FOOD CABINET-VERTICAL


FOUR DOOR REFRIGERATOR
MECHANICAL
INSTRUMENTS

AIR FILTRATION SYSTEM AIR COMPRESSOR SYSTEM

BED HEAD PANEL MEDICAL ALARM SYSTEM

VACCUME SYSTEM TECHNICAL UNIT AREA VALVE BOX


HOSPITAL SERVICES: OXYGEN
GENERATION PLANT

OXYGEN GENERATOR PLANT FOR MEDICAL


USE.
COMPRESSED AIR PACKAGE FOR OXYGEN
GENERATION PLANT AND MEDICAL
COMPRESSED AIR .
IMPORTED 4 STAGE AIR FILTRATION
SYSTEM.
PRESSURE REDUCING STATION

LIQUID OXYGEN TANK

OXYGEN GENERATION PLANT OXYGEN ROOM


HOSPITAL SERVICES: MODULAR OPERATION THEATRE
1. Stainless steel prefabricated walls & ceilings

2. Imported antibacterial / antifungal paint

3. Imported conductive tile flooring : ESD-control tile flooring

4. Imported air ceiling management system (complete)

5. Imported clean-room luminaries with RGB and frame inside OT.

6. Door and frames : hermetically sealed sliding automatic door

TYPICAL PLAN VIEW OF OT

ULTRA MODERN O.T. LIGHTS &


OTHER EQUIPMENTS

GENERAL ARRANGEMENT OF
LIGHTS & EQUIPMENTS
SPECIFICATION OF 150 KLD STP (MODULAR
TYPE) FOR 150 BEDDED HOSPITAL
INTRODUCTION

The FMR technology is a single tank design unit;


incorporating

1.A bar screen,


2. A specially designed tank with synthetic media,
3.A lamella settler, and
4.A chlorine contact tank.

The FMR process refers to the operation of activated


sludge tanks in various configurations in a combination of

1) Suspended biomass,
2) MLSS (mixed liquid suspended solids) and
3) Attached biomass, which is attached to the FMR
media.
SPECIFICATION OF 150 KLD STP

(MODULAR TYPE) FOR 150 BEDDED

HOSPITAL
Advantages using FMR
Significant reduction in space requirement due to high
surface area & loading rate of FMR media.

Reduced power and operating costs


No Sludge recycle
No moving parts, less maintenance

FMR is best suitable when

Designing a new waste water treatment plants when


operating cost & space are constraints
Upgrading of existing waste water treatment plants
Operate plants in low temperature areas
Reduce bulking problems in existing treatment plants
FMR (FLUSHED MEDIA REACTOR ) TECHNOLOGY
SPECIFICATIONS AND PROVISIONS
S.No DESCRIPTION AREA TO BE PROVIDED
.

FLOORING
1 GRANITE FLOORING ENT. STEPS, ENT. LOBBY, RECEPTION, WAITING
AREAS,CORRIDORS
1.1 VITRIFIED TILES(600 OFFICE AREAS
X 600) FULL BODY
NANO FINISH
1.2 VITRIFIED TILES(600 ALL WARD BLOCKS , (EXCEPT CLINICAL
X 600) FULL BODY AREAS), COMMON & ATTACH TOILETS
UNPOLISHED

1.3 ANTISKID PAVEMENT PORCH, RAMP / LANDSCAPE COURTYARD


/CHEQURED TILES
1.4 KOTA STONE STORES, AHUS, ELECTRICAL ROOMS ETC,
1.5 BRICK COBA WITH ACCESSIBLE & NON ACCESSIBLE TERRACE
RUSTIC CERAMIC
TILES

DADO/SKIRTING

2 ITALIAN MARBLE LIFT FAADE WORK


WITH LAMINATED
GLASS
2.1 GRANITE STAIRCASE
2.2 VITRIFIED TILES 2100 MM HIGH IN STAIRCASE,FULL HIGHT IN
TOILET
2.3 WALL PANELLING OFFICE CORRIDOR
WITH BOARD
LAMINATES

DOORS
3 MAIN ENTRANCE SENSOR SLIDING DOORS
3.1 OTHERS DOORS OF POWDER COATED ALUMINIUM FRAME WITH
ROOMS SHUTTER & CLEAR GLASS.
3.2 TOILETS DOORS PVC SOLID CORE FRAME & SHUTTER
WINDOWS
4 ALL WINDOWS POWDER COATED ALUMINIUM SLIDING WINDOW
WITH SOLAR DOUBLE GLASS
4.1 GLAZINGS STRUCTURAL GLAZING OF SOLAR DOUBLE
GLASS
RAILING
5 STAINLESS STEEL STAIRCASES & OTHER AREAS
RAILING
FINISHING
6.1 EXTERNAL CEMENT PLASTERED SURFACE TEXTURE AND
ACP CLADDING WITH STRUCTURAL GLAZING &
WINDOW
6.2 INTERNAL FALSE CEILING IN ALL AREAS, CORRIDORS &
OTHER AREAS
PLASTIC EMULSION PAINT ON WALLS & OTHER
REQUIRED AREAS