You are on page 1of 29

1.

1 YEAST MANAGEMENT: CONCENTRATED SLURRY PROCESS


1.1.1 YEAST SOURCE

1.1.1.1 PAQT OPERATION


Yeast management: Concentrated Slurry process.

1.1.1.2 PAQT PARAMETERS


Yeast Source

1.1.1.3 FREQ OF MEASURE


Every crop.

1.1.1.4 UNIT OF MEASURE


Source batch brand

1.1.1.5 DEFINITION OF MEASURE


Source brew brand.

1.1.1.6 DEFINITION OF TRIGGER EVENTS


None applicable.

1.1.1.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.1.8 FORMULA
None applicable.
1.1.2 YEAST SOURCE GEN

1.1.2.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.2.2 PAQT PARAMETERS


Yeast Source Gen

1.1.2.3 FREQ OF MEASURE


Every crop.

1.1.2.4 UNIT OF MEASURE


Number

1.1.2.5 DEFINITION OF MEASURE


Gen number of source yeast, where Gen refers to the number of commercial
Ferments already produced by the said yeast.

1.1.2.6 DEFINITION OF TRIGGER EVENTS


None applicable.

1.1.2.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.2.8 FORMULA
None applicable.
1.1.3 % YEAST SCRAPPED BEFORE CROPPING

1.1.3.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.3.2 PAQT PARAMETERS


% yeast scrapped before cropping

1.1.3.3 FREQ OF MEASURE


Every crop.

1.1.3.4 UNIT OF MEASURE


Percent

1.1.3.5 DEFINITION OF MEASURE


% of yeast run to waste as a component of total crop, where the total crop is the sum
of the scrapped component and the cropped component.

1.1.3.6 DEFINITION OF TRIGGER EVENTS


This parameter requires the system to record both the quantity (mass or Vol) of yeast
run to waste, and the quantity cropped for re-Pitch. The start and stop times of the
cropping pump can be used to trigger these events. If the yeast is pumped
continuously between these phases then it will be necessary to trigger these events
with the appropriate valves to waste or YCV.

1.1.3.7 CONSTRAINTS OF MEASURE


Variable constraints per brewery difficult to measure, beer flow meters may be
unable to discriminate between beer and yeast, or there may be no Voltric
measurement system, and whilst the crop mass is measured by load cells, the same
may not hold true for scrapped yeast. If such measuring equipment is not available
then use the run times of the cropping pump for both scrapping and cropping the
yeast. Assume the manual gear box ratio is not changed between these two stages.

1.1.3.8 FORMULA
QuantityYeastScrapped 100
PercentageYeastScrapped
QuantityYeastScrapped QuantityYeastCropped
1.1.4 YEAST CROPPING VELOCITY

1.1.4.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.4.2 PAQT PARAMETERS


Yeast cropping velocity

1.1.4.3 FREQ OF MEASURE


Every crop.

1.1.4.4 UNIT OF MEASURE


M/sec

1.1.4.5 DEFINITION OF MEASURE


This refers to the velocity of yeast pumped through the cropping mains.

1.1.4.6 DEFINITION OF TRIGGER EVENTS


The quantity and Time of the yeast cropping phase are required, when the FV outlet
valve is open, the cropping valve into the YCV is open, the cropping pump is running,
and change is detected at the YCV load cells.

1.1.4.7 CONSTRAINTS OF MEASURE


None applicable. Assume 1 hl of yeast = 100 kgs.

1.1.4.8 FORMULA
VolumePumped hl
FluidVeloc ity MetersPerSecond 10


PumpDurationmin 60 Pi PipeRadius mm 10 3
2

1.1.5 YEAST CHILLING (YCV)

1.1.5.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.5.2 PAQT PARAMETERS


Yeast chilling (YCV)

1.1.5.3 FREQ OF MEASURE


every YCV.

1.1.5.4 UNIT OF MEASURE


Celsius

1.1.5.5 DEFINITION OF MEASURE


Temp of yeast 30 minutes after completion of filling Yeast Cropping Vessel.

1.1.5.6 DEFINITION OF TRIGGER EVENTS


The 30 minutes count down time is started when the Yeast Cropping Vessel inlet
valve closes at the end of the cropping phase.

1.1.5.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.5.8 FORMULA
None applicable.
1.1.6 YEAST STORAGE TIME

1.1.6.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.6.2 PAQT PARAMETERS


Yeast storage time

1.1.6.3 FREQ OF MEASURE


every YCV.

1.1.6.4 UNIT OF MEASURE


hours

1.1.6.5 DEFINITION OF MEASURE


Yeast vessel Occup from YCV full to start of Pitch (pitch vessel included if used).

1.1.6.6 DEFINITION OF TRIGGER EVENTS


From when YCV filling/cropping is completed as defined above until the start of
the yeast Pitch pump.

1.1.6.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.6.8 FORMULA
None applicable.
1.1.7 STORAGE YEAST TEMP INCREASE

1.1.7.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.7.2 PAQT PARAMETERS


Storage yeast Temp increase

1.1.7.3 FREQ OF MEASURE


every Pitch.

1.1.7.4 UNIT OF MEASURE


Celsius

1.1.7.5 DEFINITION OF MEASURE


Delta between Yeast chilling Temp and yeast Pitch Temp

1.1.7.6 DEFINITION OF TRIGGER EVENTS


None applicable. Yeast chilling Temp as defined above, Pitch Temp ditto.

1.1.7.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.7.8 FORMULA
None applicable.
1.1.8 YEAST SLURRY VELOCITY

1.1.8.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.8.2 PAQT PARAMETERS


Yeast slurry velocity

1.1.8.3 FREQ OF MEASURE


Every Pitch.

1.1.8.4 UNIT OF MEASURE


m/sec

1.1.8.5 DEFINITION OF MEASURE


This refers to the velocity of yeast during Pitch.

1.1.8.6 DEFINITION OF TRIGGER EVENTS


Pitch pump running, yeast injection valve open.

1.1.8.7 CONSTRAINTS OF MEASURE


Derive Vol from mass, assume yeast density = 100kg per hl.

1.1.8.8 FORMULA
VolumePumped hl
FluidVeloc ity MetersPerSecond 10


PumpDurationmin 60 Pi PipeRadius mm 10 3
2

1.1.9 YEAST PITCH TIME

1.1.9.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.9.2 PAQT PARAMETERS


Yeast Pitch Time

1.1.9.3 FREQ OF MEASURE


Every Pitch.

1.1.9.4 UNIT OF MEASURE


Percent

1.1.9.5 DEFINITION OF MEASURE


% Time of yeast Pitch relative to Time of wort collection, both measured in minutes.

1.1.9.6 DEFINITION OF TRIGGER EVENTS


Both Time of Pitch and wort cooling are defined above.

1.1.9.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.9.8 FORMULA
DurationOf YeastPitching 100
YeastPitchingDuratio n
DurationOf WortCooling
1.1.10 CIP OF VESSELS

1.1.10.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.10.2 PAQT PARAMETERS


CIP of Vessels

1.1.10.3 FREQ OF MEASURE


After every successful CIP.

1.1.10.4 UNIT OF MEASURE


Number

1.1.10.5 DEFINITION OF MEASURE


Date and time of Yeast room vessel/s CIP on completion of successful CIP

1.1.10.6 DEFINITION OF TRIGGER EVENTS


On completion of a successful CIP a message is sent from the control system to
InSQL/RSBatch/InBatch.

1.1.10.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.10.8 FORMULA
None applicable.
1.1.11 CIP OF YEAST MAINS

1.1.11.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.11.2 PAQT PARAMETERS


CIP of Yeast Mains

1.1.11.3 FREQ OF MEASURE


After every successful CIP.

1.1.11.4 UNIT OF MEASURE


Number

1.1.11.5 DEFINITION OF MEASURE


Date and time of Yeast mains CIP on completion of successful CIP

1.1.11.6 DEFINITION OF TRIGGER EVENTS


On completion of a successful CIP a message is sent from the control system to
InSQL/RSBatch/InBatch.

1.1.11.7 CONSTRAINTS OF MEASURE


None applicable.

1.1.11.8 FORMULA
None applicable.
1.1.12 YEAST PITCH TEMP (AVE, MAX, MIN, STD DEV)

1.1.12.1 PAQT OPERATION


Yeast management: Concentrated Slurry process

1.1.12.2 PAQT PARAMETERS


Yeast Pitch Temp

1.1.12.3 FREQ OF MEASURE


every Pitch.

1.1.12.4 UNIT OF MEASURE


Celsius

1.1.12.5 DEFINITION OF MEASURE


Temp of wort measured in line during yeast Pitch.

1.1.12.6 DEFINITION OF TRIGGER EVENTS


During wort cooling, the start trigger is when the yeast Pitch valve is open and
the Pitch pump is running. The stop trigger ir when the valve is closed and the
pump is stopped.

1.1.12.7 CONSTRAINTS OF MEASURE


The Temp must be recorded in InSQL at least once per minute.

1.1.12.8 FORMULA
Ave, Max, Min, Std Dev are all required.
1.2 YEAST MANAGEMENT: DILUTED SLURRY PROCESS
1.2.1 YEAST SOURCE

1.2.1.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.1.2 PAQT PARAMETERS


Yeast Source

1.2.1.3 FREQ OF MEASURE


Every crop.

1.2.1.4 UNIT OF MEASURE


Source batch

1.2.1.5 DEFINITION OF MEASURE


Source brew brand.

1.2.1.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast process.

1.2.1.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.1.8 FORMULA
None applicable.
1.2.2 YEAST SOURCE GEN

1.2.2.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.2.2 PAQT PARAMETERS


Yeast Source Gen

1.2.2.3 FREQ OF MEASURE


Every crop

1.2.2.4 UNIT OF MEASURE


Number

1.2.2.5 DEFINITION OF MEASURE


Gen number of source yeast

1.2.2.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.2.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.2.8 FORMULA
None applicable.
1.2.3 % YEAST SCRAPPED BEFORE CROPPING

1.2.3.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.3.2 PAQT PARAMETERS


% yeast scrapped before cropping

1.2.3.3 FREQ OF MEASURE


Every crop

1.2.3.4 UNIT OF MEASURE


Percent

1.2.3.5 DEFINITION OF MEASURE


% of yeast run to waste as a component of total crop

1.2.3.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.3.7 CONSTRAINTS OF MEASURE


As above for concentrated yeast.

1.2.3.8 FORMULA
None applicable.
1.2.4 YEAST CROPPING VELOCITY

1.2.4.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.4.2 PAQT PARAMETERS


Yeast cropping velocity

1.2.4.3 FREQ OF MEASURE


Every crop

1.2.4.4 UNIT OF MEASURE


m/sec

1.2.4.5 DEFINITION OF MEASURE


As above for concentrated yeast.

1.2.4.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.4.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.4.8 FORMULA
VolumePumped hl
FluidVeloc ity MetersPerSecond 10


PumpDurationmin 60 Pi PipeRadius mm 10 3
2

1.2.5 YEAST DIL WATER TEMP

1.2.5.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.5.2 PAQT PARAMETERS


Yeast Dil water Temp

1.2.5.3 FREQ OF MEASURE


every YCV

1.2.5.4 UNIT OF MEASURE


Celsius

1.2.5.5 DEFINITION OF MEASURE


Temp of water in YCV prior to yeast Add

1.2.5.6 DEFINITION OF TRIGGER EVENTS


Measure Temp of water in YCV as the inlet valve opens for the yeast crop.

1.2.5.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.5.8 FORMULA
None applicable.
1.2.6 YEAST RESIDENCE TIME IN YCV

1.2.6.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.6.2 PAQT PARAMETERS


Yeast residence time in YCV

1.2.6.3 FREQ OF MEASURE


every YCV

1.2.6.4 UNIT OF MEASURE


hours

1.2.6.5 DEFINITION OF MEASURE


Yeast vessel Occup from YCV full to start of Pitch (pitch vessel included if used)

1.2.6.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.6.7 CONSTRAINTS OF MEASURE


As above for concentrated yeast.

1.2.6.8 FORMULA
None applicable.
1.2.7 YEAST TEMP INCREASE IN YCV

1.2.7.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.7.2 PAQT PARAMETERS


Yeast Temp increase in YCV

1.2.7.3 FREQ OF MEASURE


every Pitch

1.2.7.4 UNIT OF MEASURE


Celsius

1.2.7.5 DEFINITION OF MEASURE


Delta Temp of yeast/water slurry from end of cropping to start of Pitch. This must
be measured initially in YCV, and later in the batching/Pitch vessel, if used.

1.2.7.6 DEFINITION OF TRIGGER EVENTS


The start trigger is the end of cropping, when the inlet valve to YCV is closed, and
the end trigger is the start of Pitch, when the Pitch valve is open and the Pitch pump
is running.

1.2.7.7 CONSTRAINTS OF MEASURE


None.

1.2.7.8 FORMULA
YeastTemperatureIncreaseInYcv YeastTempAfterCropping YeastTempAtPitching
1.2.8 YPV CONTENTS LEVEL

1.2.8.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.8.2 PAQT PARAMETERS


YPV Contents level

1.2.8.3 FREQ OF MEASURE


Every YPV

1.2.8.4 UNIT OF MEASURE


Yes/No

1.2.8.5 DEFINITION OF MEASURE


This is the attainment of a pre-determined liquid level in YPV. Each filling of YPV
must achieve a predetermined level, such that effective cooling control and yeast
Pitch Time can be achieved. This is achieved by topping up each YPV with yeast Dil
water. Either level switch or manual input.

1.2.8.6 DEFINITION OF TRIGGER EVENTS


Determine whether predetermined level was reached once cropping has been
completed (as above).

1.2.8.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.8.8 FORMULA
None applicable.
1.2.9 CHILLING RATE IN YPV

1.2.9.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.9.2 PAQT PARAMETERS


Chilling rate in YPV

1.2.9.3 FREQ OF MEASURE


Every YPV

1.2.9.4 UNIT OF MEASURE


Yes/No

1.2.9.5 DEFINITION OF MEASURE


Each filling of YPV must achieve a predetermined level, such that effective cooling
control and yeast Pitch Time can be achieved. This is achieved by topping up each
YPV with yeast Dil water. Either level switch or manual input. This is time dependent.

1.2.9.6 DEFINITION OF TRIGGER EVENTS


Level sensor energised, or Vol metered to set point.

1.2.9.7 CONSTRAINTS OF MEASURE


This requires a level probe or Vol metering system in the YPV.

1.2.9.8 FORMULA
None.
1.2.10 MIN STORAGE TEMP IN YPV

1.2.10.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.10.2 PAQT PARAMETERS


Min storage Temp in YPV

1.2.10.3 FREQ OF MEASURE


Every YPV

1.2.10.4 UNIT OF MEASURE


Celsius

1.2.10.5 DEFINITION OF MEASURE


This is the lowest emperature measured in YPV.

1.2.10.6 DEFINITION OF TRIGGER EVENTS


Start trigger = closing of YPV inlet valve after transfer, until commencement of
yeast Pitch as above.

1.2.10.7 CONSTRAINTS OF MEASURE


The Temp must be recorded in InSQL at least once per minute.

1.2.10.8 FORMULA
Record Min Temp.
1.2.11 YEAST STORAGE TIME

1.2.11.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.11.2 PAQT PARAMETERS


Yeast storage time

1.2.11.3 FREQ OF MEASURE


Every YCV & YPV

1.2.11.4 UNIT OF MEASURE


Hours

1.2.11.5 DEFINITION OF MEASURE


Time measured from when YCV is full to the end of Pitch.

1.2.11.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.11.7 CONSTRAINTS OF MEASURE


As above for concentrated yeast.

1.2.11.8 FORMULA
None applicable.
1.2.12 YEAST PITCH VELOCITY

1.2.12.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.12.2 PAQT PARAMETERS


Yeast Pitch velocity

1.2.12.3 FREQ OF MEASURE


M/sec

1.2.12.4 UNIT OF MEASURE


Every Pitch

1.2.12.5 DEFINITION OF MEASURE


As above for concentrated yeast.

1.2.12.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.12.7 CONSTRAINTS OF MEASURE


As above for concentrated yeast.

1.2.12.8 FORMULA
VolumePumped hl
FluidVeloc ity MetersPerSecond 10

PumpDurationmin 60 Pi PipeRadius mm 10 3


2
1.2.13 YEAST PITCH TIME

1.2.13.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.13.2 PAQT PARAMETERS


Yeast Pitch Time

1.2.13.3 FREQ OF MEASURE


every Pitch

1.2.13.4 UNIT OF MEASURE


% Time of wort collection

1.2.13.5 DEFINITION OF MEASURE


As above for concentrated yeast.

1.2.13.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.13.7 CONSTRAINTS OF MEASURE


As above for concentrated yeast.

1.2.13.8 FORMULA
As above for concentrated yeast.
1.2.14 CIP OF VESSELS

1.2.14.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.14.2 PAQT PARAMETERS


CIP of Vessels

1.2.14.3 FREQ OF MEASURE


After every successful CIP.

1.2.14.4 UNIT OF MEASURE


Number

1.2.14.5 DEFINITION OF MEASURE


Date and time of Yeast room vessel/s CIP on completion of successful CIP.

1.2.14.6 DEFINITION OF TRIGGER EVENTS


On completion of a successful CIP a message is sent from the control system
to InSQL/RSBatch/InBatch.

1.2.14.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.14.8 FORMULA
None applicable.
1.2.15 CIP OF YEAST MAINS

1.2.15.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.15.2 PAQT PARAMETERS


CIP of Yeast Mains

1.2.15.3 FREQ OF MEASURE


After every successful CIP.

1.2.15.4 UNIT OF MEASURE


Number

1.2.15.5 DEFINITION OF MEASURE


Date and time of Yeast mains CIP on completion of successful CIP.

1.2.15.6 DEFINITION OF TRIGGER EVENTS


On completion of a successful CIP a message is sent from the control system to
InSQL/RSBatch/InBatch.

1.2.15.7 CONSTRAINTS OF MEASURE


None applicable.

1.2.15.8 FORMULA
None applicable.
1.2.16 YEAST PITCH TEMP

1.2.16.1 PAQT OPERATION


Yeast Management: Diluted Slurry process

1.2.16.2 PAQT PARAMETERS


Yeast Pitch Temp

1.2.16.3 FREQ OF MEASURE


every Pitch

1.2.16.4 UNIT OF MEASURE


Celsius

1.2.16.5 DEFINITION OF MEASURE


As above for concentrated yeast.

1.2.16.6 DEFINITION OF TRIGGER EVENTS


As above for concentrated yeast.

1.2.16.7 CONSTRAINTS OF MEASURE


As above for concentrated yeast.

1.2.16.8 FORMULA
As above for concentrated yeast.

You might also like