You are on page 1of 2

Diseo de lnea de conduccin

Datos de diseo
Q Diseo = Q max.Diario = 13.78 . . . = 0.137793 / = 4.8660 3 / 5 3 /

0.137793 35.3147 3
( )( ) = 4.8660 3 /
3
CRP de Mampostera = 0+800
VEAS

0+400
1+200
1+600
VEA = 2
D1 = 56.23m
D2= 53.04m
DT= 110m
L1= 800m
L2= 1000m
LT=1800m
Nivel caja rompedora= 1612.4m
Clculos
1.
56.23
1 = = 0.070288
800
53.04 3
2 = = 0.050040
1000

2.
0.070288
1 = = 3.70
(0.13779)2
0.050040
2 = = 2.64
(0.13779)2

3.
k10 = 1.54 Tramo 1
k8 = 5.07
k10 = 1.54 Tramo 2
k8 = 5.07
4.
10" = (0.13779)2 (1.54) = 0.029239
8" = (0.13779)2 (5.07) = 0.096259

5.

56.23 (800)(0.096259)
10" = = 310.02
0.096259 0.029239
56.23 (800)(0.029239
8" = = 481.98
0.096259 0.029239
= 800

2
50.04 (1000)(0.096259)
10" = = 689.63
0.096259 0.029239
50.04 (1000)(0.029239
8" = = 310.37
0.096259 0.029239
= 1000

6.
1
10" = (0.13779)2 (1.54)(310.02) = 9.06
8" = (0.13779)2 (5.07)(489.98) = 47.17
= 56.23

2
10" = (0.13779)2 (1.54)(609.63) = 20.16
10" = (0.13779)2 (5.07)(310.37) = 29.88
= 50.04

7.
0.13779
10" = = 2.72 /
0.050645
0.13779
8" = = 4.25 /
0.050645


1(10")
10" = = 4"
3
1(8")
8" = = 3"
3