You are on page 1of 3

MIRA Contactors and Overload Relays

Control Coil Specifications

MIRA 4 Pole
Contactor Coils
Frame size 18AF 22AF/40AF 85AF

MRC-50A/4
MRC-9A/4 MRC-22A/4
Contactor Model Number MRC-65A/4
MRC-12A/4 MRC-32A/4
MRC-75A/4
MRC-18A/4 MRC-40A/4
MRC-85A/4

Contactor coil

AC 50/60Hz VAC 24, 48, 120, 220, 240, 380V


Control
voltage,
Uc
AC 60Hz VAC 208, 277, 480, 600V

Pick-up
Voltage limit, Uc 85 ~110%
Drop-out
Coil consumption at 68F (20 C)

AC 220V Inrush VA 70 95 220


50/60 Hz Holding VA 9 9 17
Power Consumption W 2.3 2 5

Operating Closing ms 15~30 10~17 16~25


time Opening ms 4~9 6~9 8~15

www.franklin-controls.com | 1.800.962.3787
4-pole contactors

Control Coil Specifications

MIRA 4 Pole
Contactor Coils
Frame size 225AF 400AF 800AF

Contactor Model Number MRC-185A MRC-330A MRC-630A


MRC-225A MRC-400A MRC-800A

Contactor coil
24~25 / 24 - -
AC 50/60Hz / DC V 48~50 / 48 - 100~127 / 100~110
Control 100~240 / 100~220 100~240 / 100~220 200~240 / 200~220
voltage,
Uc 265~347 265~347 265~347
AC 50/60 Hz V 380~450 380~450 380~450
440~575 440~575 440~575

Pick-up
Voltage limit, Uc 85 ~110%
Drop-out
Coil consumption at 68F (20 C)

AC 220V Inrush VA 380 571 1000


50/60 Hz Holding VA 11.6 14 29
Power Consumption W 4.7 5 7.8

Operating Closing ms 70 55 75
time Opening ms 70 55 75
MIRA Contactors and Overload Relays

MIRA Replacement Coils:

4 Pole Contactor Replacement Coils - MRC-9A/4~MRC-85A/4


VAC 50/60 Hz VAC 60 Hz
Contactor
Coil Voltages Coil Part # Coil Voltages Coil Part #
24VAC MC-9A-18A/4P 24VAC 208VAC MC-9A-18A/4P 208VAC
48VAC MC-9A-18A/4P 48VAC 277VAC MC-9A-18A/4P 277VAC
MRC-9A/4 120VAC MC-9A-18A/4P 120VAC 480VAC MC-9A-18A/4P 480VAC
MRC-12A/4
MRC-18A/4 220VAC MC-9A-18A/4P 220VAC 600VAC MC-9A-18A/4P 600VAC
240VAC MC-9A-18A/4P 240VAC - -
380VAC MC-9A-18A/4P 380VAC - -
24VAC MC-22A-40A/4P 24VAC 208VAC MC-22A-40A/4P 208VAC
48VAC MC-22A-40A/4P 48VAC 277VAC MC-22A-40A/4P 277VAC
MRC-22A/4 120VAC MC-22A-40A/4P 120VAC 480VAC MC-22A-40A/4P 480VAC
MRC-32A/4
MRC-40A/4 220VAC MC-22A-40A/4P 220VAC 600VAC MC-22A-40A/4P 600VAC
240VAC MC-22A-40A/4P 240VAC - -
380VAC MC-22A-40A/4P 380VAC - -
24VAC MC-50A-85A/4P 24VAC 208VAC MC-50A-85A/4P 208VAC
48VAC MC-50A-85A/4P 48VAC 277VAC MC-50A-85A/4P 277VAC
MRC-50A/4
MRC-65A/4 120VAC MC-50A-85A/4P 120VAC 480VAC MC-50A-85A/4P 480VAC
MRC-75A/4 220VAC MC-50A-85A/4P 220VAC 600VAC MC-50A-85A/4P 600VAC
MRC-85A/4
240VAC MC-50A-85A/4P 240VAC - -
380VAC MC-50A-85A/4P 380VAC - -

4 Pole Contactor Replacement Coils MRC-100A/4~MRC-800A/4


VAC 50/60 Hz / VDC VAC 50/60Hz
Contactor
Coil Voltages Coil Part # Coil Voltages Coil Part #
300VAC
24V (24~25VAC) MC-100A-225A/4P 300VAC
MC-100A-225A/4P 24V (265~347VAC)
24V (24VDC) - -
MRC-100A/4
MRC-130A/4 400VAC
48V (48~50VAC) MC-100A-225A/4P 400VAC
MRC-150A/4 MC-100A-225A/4P 48V (380~450VAC)
MRC-185A/4 48V(48VDC) - -
MRC-225A/4
500VAC
100V (100~240VAC) MC-100A-225A/4P 500VAC
MC-100A-225A/4P 100V (440~575VAC)
100V (100~120VDC) - -
300VAC
100V (100~240VAC) MC-330A-400A/4P 300VAC
(265~347VAC)
MC-330A-400A 100V
MRC-330A 400VAC
100V (100~220VDC) MC-330A-400A/4P 400VAC
MRC-400A (380~450VAC)
500VAC
- - MC-330A-400A/4P 500VAC
(440~575VAC)
300VAC
100V (100~127VAC) MC-630A-800A/4P 300VAC
(265~347VAC)
MC-630A-800A 100V
400VAC
MRC-630A 100V (100~110VDC) MC-630A-800A/4P 400VAC
(380~450VAC)
MRC-800A 500VAC
200V (200~240VAC) MC-630A-800A/4P 500VAC
MC-630A-800A 200V (440~575VAC)
200V (200~220VDC) - -

www.franklin-controls.com | 1.800.962.3787