IS 5334 (2003): Magnetic Particle Flaw Detection of Welds -


Code of Practice [MTD 21: Non-Destructive Testing]

! $ ' +-
Satyanarayan Gangaram Pitroda
Invent a New India Using Knowledge

! > 0 B


BharthariNtiatakam
Knowledge is such a treasure which cannot be stolen
Indian Standard
MAGNETIC PARTICLE FLAW DETECTION OF
WELDS CODE OF PRACTICE
(Second Revision )

ICS 77.040.20

0 BIS 2003

BUREAU OF INDIAN STANDARDS


MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002
October 2003
Price Group 2
/
Non-destructive Testing Sectional Committee, MTD21

FOREWORD

This Indian Standard ( Second Revision) was adopted by the Bureau of Indian Standards, after the draft finalized
by the Non-destmctive Testing Sectional Committee had been approved by the Metallurgical Engineering Division
Council.

This standard was first published in 1969 and was revised in 1981 giving detailed requirements about the test
procedure and modifiing the requirements for magnetizing the work-piece. While reviewing this standard, the
Committee decided to revise this standard in order to bring it in line with the present practices being followed in
the country.
In this revision following modifications have been carried out:

a) Scope has been modified;

b) Reference clause has been added;

c) Requirement of surface condition has been modified;

d) Requirement of magnetizing current has been modified; and

e) Requirement of qualified personnel has been added to carry out testing.


For the purpose of deciding whether a particular requirement of this standard is complied with the final
value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance
with IS 2: 1960 Rules for rounding off numereicalvalues ( ~evised ). The number of Signiflcantplaces retained
in the rounded off value should be the same as that of the specified value in this standard.
IS 5334:2003

Indian Standard
MAGNETIC PARTICLE FLAW DETECTION OF
WELDS CODE OF PRACTICE
(Second Revision )
1 SCOPE applying magnetic particles to the surface and
observing the particle pattern. The particles retained
1.1 This standard prescribes the recommended on the surface due to the leakage field form patterns
procedure for detection of surface and sub-surface that are characteristic of the type of flaws present.
discontinuities in welds by the magnetic particle This method is suitable for surface and sub-surface
inspection method. The method is applicable only flaws only and is not suitable for deep-seated flaws,
to materials in which the weld metal is ferromagnetic. since the sensitivity decreases sharply with the depth
1.2 Thk standard does not lay down any requirements of location of the flaws.
for the acceptance or rejection of welds which shall S SURFACE CONDIT-ION
be the subject of mutual agreement to between the
contracting parties. This agreement may provide details The surface to be examined shall be clean, dry and
with regard to: free from rust, oil, scale, excessive slag and other
extraneous matter which may interfere with the
a) welds or sections of welds to be inspected, sensitivity of examination. In general, satisfactory
b) techniques to be used, results may be obtained whemthe surface is in the as
welded condition. However, rough surfaces hamper
c) type of discontinuities to be accepted, and
the mobility of magnetic particles due to mechanical
d) re-working and subsequent retesting which trapping which in turn produces false indications. In
may be permissible. such cases, surface preparation by wire brushing,
2 REFERENCES sand blasting, grinding, machining or any other
suitable method is necessary. To reveal fine defects,
The following standards contain provisions which the surfaces to be inspected should be smooth
through reference in this text, constitute provisions machined to at least a 6.3 microns finish. However, a
of this standard. At the time of publication, the thin layer of paint of 0.05 mm maximum thickness does
editions indicated were valid. All standards are not interfere with the formation of indications, but
subject to revision and parties to agreements based must be removed at points where electrical contact
on this standard are encouraged to investigate the is to be made.
possibility of applying the most recent editions of
the standards indicated below: 6 TYPES OF PARTICLES
Magnetic particles used for detection of flaws
1S No. Title
may be of the dry or wet type in either visible ( colour
3415:1980 Glossary of terms used in magnetic contrast ) or fluorescent form.
particle flaw detection ( second
6.1 If dry particles are used as the examination
revision )
medium, they shall be of high magnetic permeability
3703:1980 Code of practice for magnetic particle and low magnetic retentivity and shall be of such size
flaw detection (first revision ) and shape as will produce suitable indications. It is
13805:1993 Guidelines for certification for desirable that the colour be such as to provide adequate
personnel for non-destructive contrast with the background of the surface being
testing examined.

3 TERMINOLOGY 6.2 If wet particles are used, the particles shall be


red, black, grey or yellow, or of fluorescent type when
For the purpose of this standard, the definitions viewed-under ultraviolet illumination. These particles
given inIS3415 shall apply. would be suspended in a liquid medium, the bath
4 PRINCIPLE OF METHOD strength of which shall be as given in IS 3703. The
bath shall be thoroughly stirred and the strength
This method of flaw detection consists of ( concentration) and condition checked at frequent
magnetizing the weld and the heat affected zone, intervals.
1
IS 5334:2003

6.3 The dry powder method is more sensitive than periodically once in a year or immediately after it has
the wet method in the detection of near surface undergone major overhaul to ensure that the equipment
discontinuities, but is less sensitive in detecting has the required sensitivity and delivers the specified
fine surface discontinuities. It is also convenient to current as shown by the ammeter.
use in conjunction with _portable equipment for the
7.1.5 In order to avoid damage as a result of burning
inspection of large areas or for field operation. It is,
and to improve the contact efficiency, both test material
therefore, often used for the examination of heavy
and the tip of the electrode must be kept well ground.
weldments and parts with rough surfaces. In
If necessary, electrodes maybe provided with contact
comparison, wet method is good for parts with rough
pads. Elimination of arcing isvery important for testing
surfaces and for parts which are small in size and tested
high carbon steels and alloy steels as this can cause
with stationary equipment.
hard spots or cracks.
7 METHODS OF MAGNETIZATION
7.1.6 To eliminate arcing, magnetizing current should
A suitable and appropriate means for establishing not be turned on until after the prods have been
the necessary magnetic flux in the job, as described properly positioned in contact with the surface and
below, may be used. the current shall be turned off before the prods are
removed. For this purpose it is further desirable to
7.1 Local Circular Magnetization -( or Prod have a remote control switch built into the prod
Magnetization ) handles.
7.1.1 Local circular magnetization is achieved by 7.1.7 Lead or steel-tipped rather than copper-tipped
the use of portable prod type electrical contacts prods are recommended where the magnetizing
pressed against the surface in the area to be examined voltage is over 25 V,in order to avoid copper penetration.
(see Fig. 1).
7.2 Longitudinal Magnetization (Yoke Method )
7.1.2 The prod spacing is usually kept between
150-200 mm. Shorter spacing may be used to meet 7.2.1 Alternating current electromagnetic yokes shall
the limitation of geometry and dimensions of area be used provided the sensitivity to detect surface cracks
being examined, or to increase the sensitivity, but prod is at least equivalent to that of the prod when a direct
spacing less than 50 mm is not recommended as it or rectified magnetizing current of 25 to 30 A/25 mm
will result into banding of the particles around the of prod spacing is used and the lifting power of yoke
prods. is at least 5 kg with a pole spacing of 75-150 mm.

7.1.3 Alternating or half wave rectified magnetizing 7.2.2 Alternatively direct current electromagnet
current shall be used. The current shall be selected or permanent magnet yoke may be used -if it has
as below depending upon the thickness of the jobs got a lifting power of 20 kg with a pole spacing of
being tested: 75-150 mm, other conditions remaining the same.

Thickness Range Current Requirement per 7.3 A suitable instrument, such as magnetic field
25 mm of Prod Spacing indicator, as shown in Fig. 2 should be used, whenever
necessary, to establishthe adequacy of magnetic field.
Under 20 mm 90 to 110 ampere The indicator should be positioned on the weld being
examined while applying the required current and
20 mm and over 100 to 125 ampere
ferromagnetic particles. The formulation of particles
7.1.4 A suitable instrument shall be used to measure indicates that adequate field strength has been
the current. The equipment shall be calibrated generated in the welding to be examined.

AGNETIZING
CURRENT

FIG. 1 PROD MAGNETIZATION

2
IS 5334:2003

.
NON-FERROUS HANDLE
OF CONVENIENT LENGTH

1
{

J)

/
8CARBON STEEL
SECTIONS BRAZED
BRAZED WELOED OR MECHANICALLY
ATTACHED NON-FERROUS TRUNIONS
TOGETHER
1 rCOPPER SHEET OF ABOUT 0.25mm THICKNES5

FIG.2 MAGNETICFIELDINDICATOR

When a clearly defined pattern of particles is not the job. An applicator may be used for rapid and
formed, or not formed in the desired direction, the uniform application of dry powder and any excess
magnetizing technique shall be changed or adjusted powder may be removed with a gentle air stream. The
to obtain it. air system should not disturb or remove lightly held
particle patterns. In order to recognize the broad,
7.4 Direction of Magnetization
fuzzy indication it is essential to observe carefully
Since proper indications are obtained when the the formation of indications, while the particles are
discontinuities are perpendicular to the direction of being applied and also while any excess is being
magnetic field, at least two seperate examinations shall removed. Proper lighting will facilitate the observation
be carried out on each area. The prod or yoke shall of these patterns. The temperature of the dry particles
be placed such that the magnetic field during one case and of the surface of the -part shall not exceed the
is approximately perpendicular to that during the other. Curie temperature 315C.

7,5 Examination shall be done by the continuous 9 EXAMINATION


method, that is, the magnetization current must remain
9.1 Discontinuities are indicated by retention of the
on while the examination medium is applied and while
magnetic particles.
excess of examination medium is being removed.
Residual method shall be used only if approved by 9.2 The lighting used for the purpose shall be adequate
the purchaser. without creating shadows and highlights. When using
7.6 Examination shall be conducted with sufficient fluorescent powders, the inspection area should be
overlap to ensure cent percent coverage. darkened. Black light provided with filter to pass
mainly near ultraviolet rays of ( 3300-3900 ~ ) and
7.7 For the examination of wslds, care must be taken having the strength to discriminate the fluorescent
on the following items: magnetic particle indications shall be used.
a) When the heat treatment is done on a welded 9.3 A low powered optical magnifier is a desirable
part after welding, the examination for the inspection aid, particularly when very small flaws are
determination of acceptance or otherwise shall to be examined.
be conducted after heat treatment; and
9.4 Flaws requiring repair or investigation should be
b) The magnetic particle examination after heat
marked out clearly using grease, pencil, coloured
t~eatment of welded part, of afier completion
crayon or paint.
of pressure test of pressure vessel shall, as
a rule, be of yoke type. 9.5 A permanent record maybe made by photographs
or transfer. Transfer of any indication may easily be
8 APPLICATION OF MAGNETIC PARTICLES
made by carefully pressing transparent pressure
The magnetic particles shall be applied immediately sensitive tape down over the indication. The tape is
prior to the application of magnetizing current or while then removed with the indication adhering to it. This
the magnetizing current is on by sp~aying the liquid may then be placed on a piece ~f white paper, or directly
suspension, or by lightly dusting dry powder over on a sketch or report to form a permanent record.
3
IS 5334:2003

10 ASSESSMENT OF FLAWS arc-welding operations, or with structures, such as


aircraft, where sensitive electrical instruments may
10.1 If the indication is caused by the surface
be affected by the residual magnetic field.
discontinuities, the particles are usually tightly held
to the surface by a relatively strong magnetic field. 11.2 Demagnetization, if required, shall be clearly
The line of particles shall be sharp and well defined. specified in drawing/purchase orders. The level of
But, if the indication is caused by sub-surface residual magnetism and the measuring method shall
discontinuity, the particles are held in a broad fuzzy also be specified.
accumulation rather than in sharp and well defined
patterns. 12 PROTECTION

10.2 Relevant indications are those which results Since the weld had been cleaned prior to magnetic
from mechanical discontinuities. particle inspection, it is liable to rusting unless
protected. Temporary corrosion protective may be
10.3 Non-relevant indications are caused by distortion applied over the component after magnetic particle
of magnetic field resulting from magnetic writing, cold inspection.
working, hard and soft spots, boundaries of heat
affected zones, abrupt change of section, etc. Care 13 RECORD OF TEST DATA
shall be taken to identify and eliminate them, as they
Magnetic particle flaw detection of welds shall be
may mask the actual defects.
carried out by qualified personnel ( see IS 13805 ).
10.4 Any indication suggested to be non-relevant
13.1 The following data shall be recorded at the time
is to be considered relevant till it is proved otherwise.
of each test for further reference:
10.5 Broad areas of particle accumulation which
could mask indications of discontinuities are a) Name and reference number of the part;
unacceptable and these areas shall be cleaned and b) Material sectional thickness, type of weld;
re-examined. .C) Method used, dry or wet;
10.6 Linear indications are those in which the length d) Type of magnetization;
is more than three times the width. e) Type of current;
10.7 Rounded indications are those which are circular o Amount of current;
or elliptical with the length less than three times the Location and nature of defects;
g)
width.
h) Details of the machine;
11 DEMAGNETIZATION Name and certification level of the operator
J)
11.1 Demagnetization is unnecessary unless the conducting the test; and
residual field interferes with subsequent machining, k) Other information, if necessary.

4
Bureau of Indian Standards

BIS is a statutory institution established under the Bureau OJ Indian Standards Act, 1986 to promote
harmonious development of the activities of standardization, marking and quality certification of goods and
attending to connected matters in the country.

Copyright

BIS has the copyright of all its publications. No part of these publications maybe reproduced in any form without
the prior permission in writing of BIS. This does not preclude the free use, in the course of implementingthe
standard, of necessary details, such as symbols and sizes, type or grade designations. Enquiries relating to
copyright be addressed to the Director (Publications), BIS.

Review of Indian Standards

Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed
periodically; a standard along with amendments isreaffirmed when such review indicates thatno changes are
needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards
should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue
of BIS Catalogue and Standards : Monthly Additions.

This Indian Standard has been developed from Doc : No. MTD 21 ( 3610 ).

Amendments Issued Since Publication

Amend No. Date of Issue Text Affected

BUREAU OF INDIAN STANDARDS


Headquarters:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002 Telegrams: Manaksanstha
Telephones: 23230131,23233375,2323 9402 ( Common to all offices)
Regional Offices: Telephone
Central: Manak Bhavan, 9 Bahadur Shah Zafar Marg 23237617
NEW DELHI 110002 { 23233841

Eastern: 1/14 C. 1.T. Scheme VI-IM, V. L P. Road, Kankurgachi 23378499,23378561


KOLKATA 700054 { 23378626,23379120
Northern: SCO 335-336, Sector 34-A, CHANDIGARH 160022 603843
{ 609285
Southern: C. I. T. Campus, IV Cross Road, CHENNA1 600113 22541216,22541442
{ 22542519,22542315
Western : Manakalaya,.E9 MIDC, Marol, Andheri (East) 28329295,28327858
MUMBAI 400093 { 28327891,28327892

Branches : AHMEDABAD. BANGALORE. BHOPAL. BHUBAN-ESHWAR. COIMBATORE.


FARIDABAD. GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR.
LUCKNOW. NAGPUR. NALAGARH.PATNA. PUNE. RAJKOT. THIRWANANTHAIWMM.
VISAKHAPATNAM.
Printed at New India Printing Press, Khurja, India

You might also like