high ambient air-cooled liquid chiller

YAEP
On the cover
Integrated professional services
designed for your unique business
need.

We care about your business and


understand that each business has
its unique requirements. Our
all-encompassing maintenance
package is tailor-made to fit your
every financial and technical need.
It covers from planned routine
equipment inspections and
predictive maintenance routines to
system performance checks and
2 annual shutdowns.
Available Models and Nominal Cooling Capacities

R22 Models - 50 Hertz


1 Circuit Units (2.97 m Footprint) 2 Circuit Units (2.97 m Footprint)
Model YAEP 06RA7C 07RA7C 08TA7C 09TC9C Model YAEP 75UC9C 77UC9C 77WC9C
Capacity kW (Tons) 219 (62) 257 (72) 304 (86) 372 (105) Capacity kW (Tons) 443 (125) 491 (138) 545 (153)

2 Circuit Units (5.07 m Footprint) 3 Circuit Units (9.05 m Footprint)


Model YAEP 97VB7C 99VB7C 99VD9C 99WD9C Model YAEP 997YH7C 999YK9C
Capacity kW (Tons) 626 (176) 701 (198) 749 (211) 794 (223) Capacity kW (Tons) 977 (275) 1188 (334)

4 Circuit Units (6.13 m Footprint) 4 Circuit Units (11.71 m Footprint)


Model YAEP 7575UC9C Model YAEP 9797VB7C 9999VB7C 9999VD9C 9999WD9C
Capacity kW (Tons) 886 (250) Capacity kW (Tons) 1252 (353) 1403 (395) 1498 (422) 1588 (447)

R407C Models - 50 Hertz


1 Circuit Units (2.97 m Footprint) 2 Circuit Units (2.97 m Footprint)
Model YAEP 06RA7B 07RA7B 08TC7B 09TC9B Model YAEP 55UC9B 75UC9B

Capacity kW (Tons) 206 (58) 242 (74) 300 (84) 356 (101) Capacity kW (Tons) 389 (110) 428 (120)

2 Circuit Units 2 Circuit Units 3 Circuit Unit 3 Circuit Units


(4.19 m Footprint) (5.07 m Footprint) (7.46 m Footprint) (9.05 m Footprint)
Model YAEP 77UF7B 77WF7B 97VD7B 99VD7B 99WD9B Model YAEP 777YG7B 997YJ7B 999YK9B
Capacity kW (Tons) 511 (143) 543 (153) 641 (180) 709 (200) 748 (211) Capacity kW (Tons) 829 (233) 1016 (286) 1121 (316)

4 Circuit Units (6.13 m Footprint) 4 Circuit Units (11.71 m Footprint)


Model YAEP 7575UC9B Model YAEP 9797VD7B 9999VD7B 9999WD9B
Capacity kW (Tons) 855 (241) Capacity kW (Tons) 1281 (360) 1418 (399) 1495 (421)

Cooling capacities kW at 7C leaving liquid temperature and 35C ambient.


Cooling capacities (Tons) at 44F leaving liquid temperature and 95F ambient.

3
Available Models and Nominal Cooling Capacities

Nomenclature

Y A E P 9999 W D 9 B 50 P B

YORK Design Level


Air Cooled Starting: P = Part Wind
Export Series 380/400/415 V 3 phase, 50 Hz
P Series Compressor B: R407C C: R22
Compressor 7: Standard 9: High Flow
4 = 4 Cyl. - 4 = 4 Cyl. - Short Stroke
5 = 4 Cyl. - 5 = 4 Cyl. - Long Stroke Condenser: A, B, C, D, F, G, H, I, J, K
6 = 6 Cyl. - 6 = 6 Cyl. - Short Stroke
7 = 6 Cyl. - 7 = 6 Cyl. - Long Stroke Cooler: R, T, U, V, W, Y
8 = 8 Cyl. - 8 = 8 Cyl. - Short Stroke
9 = 8 Cyl. - 9 = 8 Cyl. - Long Stroke

FEATURES BENEFITS

Constructed from heavy gauge baked polyester powder painted Aesthetically pleasing, long life durability, UV stable weather
galvanised steel panels and frame. protection.

Rated to operate in panel temperatures of up to 70C.


High ambient rated electrical components.

Separate power and control compartments with lockable doors


Operator safety and flexablity for installation.
and a choice of power input arrangements.

High ambient fans. Profiled impellor minimising sound levels for high air flow.

Providing alternative fin corrosion protection. Wide pitch


A choice of condenser fin material using 13 fins per inch pitch.
reduces the potential for dust blockage.

1, 2, 3 or 4 Refrigerant circuit models each with dedicated


System stand-by security.
compressor per circuit.

Industrial type serviceable semi-hermetic reciprocating


Long life, site maintainable, reliable compressor(s).
compressor with replaceable cylinder liners.

Manufactured to GB/T18430.1 and safety code JB8654. High standard of quality control.

Each circuit is provisionally set up and factory run tested. Operating quality control.

High ambient double skin control panel (Option). Offers panel protection from solar heat gain.

IP55 control panel. Protects the panel from water and dust infiltration.

4
Specifications

The YAEP range of chillers are designed for water cooling. Housing - The compressor housing is cast iron, and
Units are available with one, two, three or four refrigerant contains: removable cylinder heads with internal muffling,
circuits. discharge service valve, optional suction service valve,
crankcase sight glass and heater, oil and suction strainers,
All units are designed to be located outside on the roof of and internal relief valves.
a building or at ground level.
Crankshaft - The crankshaft is ductile (nodular)
iron, drilled for positive oil distribution, with integral
One and two refrigerant circuit units have one or two counterweights for balancing. The main bearings are insert
compressors and a cooler mounted on a single base with a type, steel-backed babbitt. The thrust bearing is bronze.
single power and control panel mounted at the end of the
unit. Cylinder Assemblies - Suction and discharge valves are
high-quality, non-flexing, stainless steel. The pistons are
Three refrigerant circuit units have three compressors and aluminium alloy with two piston rings. The connecting rods
a cooler mounted on a single base with power and control are aluminium alloy with integral bearing surfaces on both
panels mounted at each end of the unit. ends. Cylinder liners are removable.

Lubrication - The lubrication is force-fed by a reversible


Four refrigerant circuit units are constructed and shipped
oil pump to all crankshaft and bearing surfaces and filtered
in two sections, each having two compressors with a
through a fine mesh stainless steel oil strainer.
cooler and a power and control panel mounted at the end
of the section. Capacity Control - Capacity control is provided by,
solenoid-actuated, capacity control valves which are
Four circuit units require the installation of a two wire controlled by the microprocessor centre. These inject
communication link between control panels and a mixed high pressure oil to lift pins that close the cylinder suction
leaving liquid temperature sensor mounted in the common valves when a load requirement exists. Gas flow is
leaving liquid pipework. sufficient at all times to cool the motor.

Isolation - Each compressor is mounted on isolator pads


to reduce vibration transmission to the structure.
General
Units are completely assembled with all interconnecting
refrigerant piping and internal wiring, ready for field
Cooler(s)
installation. The unit is pressure-tested, evacuated and The single/multi-circuit cooler is the direct- expansion
fully charged with refrigerant and includes an initial oil type, with the refrigerant in the tubes and chilled liquid
charge. After assembly, a full run test is performed, with flowing through the baffled shell.
water flowing through the cooler, to verify that each
refrigeration circuit operates correctly. The design working pressure of the shell is 10.3 bar
(150 psi), and 24.0 bar (350 psi) for the tube side. The
The unit base and frame is of heavy-gauge, galvanised refrigerant side is constructed and tested in accordance
steel, with a baked-on enamel coloured Champagne with GB150 and GB151.
(Munsell No. 9.8YR4.36/1.2).
The water baffles are constructed of galvanised steel to
resist corrosion. The removable heads allow access to
Compressors the internally enhanced, seamless, copper tubes. Vent
and drain connections are included. Standard cooler
The unit has accessible, semi-hermetic, reciprocating connections are Victaulic nozzles.
c o m p re ss o rs . A l l ro t a t i n g p a r t s a re s t a t i c a l l y a n d
dynamically balanced. The cooler is covered with 19mm( inch) UV stable,
flexible, closed-cell, foam insulation. Each circuit is
Motor - The compressor motors are refrigerant gas protected by a relief valve (350 psig).
cooled, with integral temperature-sensing solid state
overload protection in each phase. The terminal boxes An optional cooler heater mat, controlled by a separate
are weather protected. Part Winding starting is fitted as thermostat, provides freeze protection for the cooler down
standard. to -29C ambient.

5
Specifications

Condenser Each panel is divided into sections; with separate power


sections serving each refrigerant circuit, a control section
Coils - The condenser coils are seamless copper tubes,
and a common input section.
arranged in staggered rows, mechanically expanded
into ripple profile aluminium fins. Integral subcooling is
Components are mounted on galvanised steel back plates,
included. The design working pressure of the coil is 31
and enclosed in the relevant section of the galvanised steel
bar (450 psi). Coils are protected by a fuseable plug relief
enclosure.
device.
Separate doors are provided for each section. All doors
The coil mounting frame, end sheets, tube supports and
are hinged, lockable with door stays and are designed to
fan separation plates of the coil mounting frames are
IP55 weather protection. Enclosure and doors are finished
constructed from unpainted galvanised steel sheets.
in zinc phosphate pre-treated baked enamel coloured
Champagne.
F a n s - T h e c o n d e n s e r f a n s a re a l u m i n i u m a l l o y,
acoustically profiled, high efficiency, airfoil-type fan blades
Each Power Section Contains:
directly driven by independent motors, and positioned for
Partwind compressor starting contactors, system fuses, fan
vertical air discharge.
contactors, fan manual motor starters and control interface
relays.
The fan guards are constructed of heavy-gauge wire hot
dipped galvanized coated steel. After construction the fan
The Common Input Section Contains:
deck and cowl are hot dipped galvanized prior to assembly.
Non-fused disconnect switch for customer single point
(Colour co-ordinated paint finish is available as an extra).
power supply connection. Transformer and wiring to allow
All blades are dynamically and statically balanced for
control voltage to be internally derived.
vibration-free operation.
The Control Section Contains:
Motors - The fan motors are Totally Enclosed Air-
microprocessor, power supply and relay boards. The relay
Over, squirrel-cage type, current protected. They feature
board contains the control circuit serving compressor
ball bearings that are double sealed and permanently
solenoids, crankcase heaters and compressor and fan
lubricated.
contactor coils.

Refrigerant Circuits Controls


Unit piping is ACR copper with brazed joints. The liquid
The microprocessor based control system is capable of
line includes: a shut off valve with charging port, sight
multi-circuit control to maintain chilled liquid temperature.
glass with moisture-indicator, thermal expansion valve
Compressor starting/stopping and loading/ unloading
(direct acting, max-operating pressure), solenoid valve,
decisions are performed by the microprocessor to maintain
and filter drier. The entire suction line, the liquid line
leaving water temperature. These decisions are a function
between the expansion valve and the cooler, are insulated
of temperature deviation from setpoint and rate of change
with flexible, UV stable colour coordinated closed-cell,
of temperature.
foam insulation.

Compressor low, high and oil pressure transducers


plus a manual high pressure cut-out are located on the Control System Keypad and Display
compressor and system pipework with Econoseal all (main power and control panel only) The backlit 40
weather electrical connectors. character display (LCD, 2 lines of 20 characters) allows the
operator to view system operating parameters as well as
access programmed information already in memory.
Power And Control Panel(s)
The user friendly keypad is provided for programming
All controls and motor starting equipment necessary for
and accessing setpoints, pressures, temperatures, motor
full unit operation are factory wired and functionally tested.
current, cut-outs, daily schedule, options and fault
One and two refrigerant circuit units have a single power
information.
and control panel and four circuit units have a two power
and control panels (main and auxiliary).

6
Specifications

reset. Settings for liquid temperature set-point reset signal


The standard controls shall include: automatic pump down from YORK ISN or building automation system.
at shutdown and recycling pumpdown, run signal contacts,
demand load limit from external building automation Remote cycling, unloading and chilled water temperature
system input, remote reset liquid temperature reset input, reset can be accomplished by voltage free customer
unit alarm contacts, chilled liquid pump control, automatic contacts.
or manual reset after power failure, automatic system
optimisation to match operating conditions, software
stored in non-volatile memory (EPROM) to eliminate chiller
failure due to AC power failure. Programmed Setpoint shall
be retained in a lithium battery backed RTC memory for a
minimum of 5 years.

For each circuit, the following items shall be displayed in


Metric (C and Bar) or Imperial (F and psi) units :

Leaving chilled liquid and ambient temperature.

Day, date and time. Daily start/stop times. Holiday and


Manual Override status.

Compressor operating hours and starts. Automatic or


manual lead/lag. Lead compressor identification.

Run permissive status. No cooling load condition.


Compressor run status.

Anti-recycle timer and anti-coincident start timer status


per compressor.

System suction, discharge, and oil pressures and


temperatures.

Percent full load compressor motor current. Compressor


capacity control valve input steps.

C u t- o u t s t a t u s a n d s e t- p o i n t s f o r : s u p p l y f l u i d
temperature, low suction pressure, high discharge
pressure, high oil temperature, low and high ambient,
high and low current, and low leaving liquid temperature.

Unloading limit setpoints for high discharge pressure and


compressor motor current.

Out of range message.

Liquid pull-down rate sensitivity (0.3C to 8C/minute in


0.1C increments).

Status of: evaporator heater, condenser fans, chilled


liquid pump.

Up to 3 fault shut down conditions.

The following settings can be programmed by the operator:


high ambient cut-out, low ambient cut-out, high motor
current unload, anti-recycle time (300 - 600 seconds),
local remote control, lead lag control and power failure

7
Accessories and Options

Single Point Power Supply Option - Per Panel Wire Panel Enclosure
Customer single point power supply connection to factory Consists of welded-wire-mesh guards mounted on
fitted terminal block (in lieu of standard non fused disconnect the exterior of the unit. Prevents unauthorized access
switch). Internal wiring to fuses in each power section. and offers coil protection, yet provides free air flow.
Alternative grills for the full unit or the condenser coil face
Multi Point Power Supply Terminal Block Option - only (field fitted option).
Per Circuit
Customer supply connection to terminal block in power Fan Deck Paint Finish
section. A separate control supply is required to the control Paint finish for fan cowl and fan deck in colour coordinated
circuit switch disconnect. Champagne.

Multi Point Power Supply Fuse Block Option - Per Handed Evaporator
Circuit Simplifies site layout by offering versatile water connection
Customer supply connection to fuse block in power section. enabling the chillers to be placed in the best orientation to
A separate control supply is required to the control circuit suite the compound.
switch disconnect.
Double Thickness Insulation
Cable Spreader Box The cooler is covered with 38 mm (1 inch) flexible, UV-
To separate cores of large multi-core cable before connection stable colour co-ordinated closed-cell, foam insulation for
to non-fused disconnect switch/terminal block when Single added frost protection.
Point Power Supply is specified.

Multi-unit Sequence Control Cooler Flange Kit


A separate sequencing control centre to manage sequencing Factory fitted weld flanges on cooler water connections to
control of up to eight chillers in parallel based on mixed HG20615(ASMEB 16.5).
leaving liquid temperature (mounting and interconnection/
wiring by others). (Cannot be used when a (BAS) Interface is Companion Flange Kit
supplied). See separate York documentation, 150.00.SG2. Weld flanges to match cooler flange kit ((HG20615(ASMEB
16.5)), supplied loose for field installation by contractor.
Building Automation System (BAS) / Energy Includes all necessary nuts, bolts, gaskets, etc.
Management System (EMS) Interface
Provides a means to reset the leaving chilled liquid Flow Switch
temperature from a BAS/EMS. Switch with 1 inch BSP thread suitable for 10 bar (145
psi) DWP and having gold contacts for low voltage/
Consists of a factory mounted PCB to accept 4 to 20 mA, 0 current, to protect unit from loss of water flow. A
to 10 Vdc, or dry contact closure input from the BAS/EMS. flow switch must be furnished with each unit for field
(Cannot be used when a Multi-unit Sequence Control is installation by contractor.
supplied).

Micro Gateway Added Compressor Capacity Step


Interface to enable communication with building control (Units with 6 and 8 cylinder compressors only)
systems using BACnet or MODBUS protocols. See separate The compressor control system is fitted with an additional
York documentation, BACNET 450.20-04, MOBUS 450.20-01. capacity step to improve part load performance. This option
includes compressor liquid injection cooling.
York Talk Translator
Provides central communication with third party BMS for Sun Shield Kit
monitoring and control of all chillers in the system. See Sun shield kit to provide shade / air gap around the power
separate York documentation, 450.20.506. and control panels to prevent overheating due to solar gain.

Condenser Coil Fin Protection Unit Aesthetic Panels


Gold Epoxy Coated Aluminium Fins Non acoustically lined infill panels manufactured from powder
Offers corrosion resistance in mild coastal locations (ASTM painted galvanised steel to cover the ends of the condenser
287* Test, after 1500 hours 7% weight loss). coil on the opposite end to the control panel.
* ASTM 287 tests are based on Industrial / Coastal locations.

8
Accessories and Options

Suction Service Valves Anti-Vibration Mounts


One ball valve per compressor in the low pressure (suction) Open spring isolator mounts with levelling screws and fixing
pipework. down holes, supplied loose for field installation by contractor.

Mechanical Gauge Kit Lifting Lug Kit


Factory fitted mechanical dial gauges for discharge, suction One set of ISO Mk5 cam locks to enable safe and easy unit
and oil pressure indication in addition to transducer pressure handling.
display.

Refrigerant Flow Diagram

Condenser Coil
Refrigerant
Circuit No 2

Condenser Coil
Refrigerant
Circuit No 1

High Pressure
superheated vapour

Compressor
Fusible
Plug Optional
Suction
Service
High pressure Valve
sub-cooled liquid

Low pressure superheated vapour

Sight TEV
Glass

Filter
Low pressure
Drier Cooler
sub-cooled
liquid/vapour

Refrigerant Circuit No 2

Low pressure liquid refrigerant enters the cooler and is evaporated and superheated by the heat energy absorbed from the
chilled water passing through the cooler shell. Low pressure vapour enters the compressor where pressure and superheat are
increased. Heat is rejected via the air cooled condenser coil and fans. The fully condensed and subcooled liquid refrigerant
then enters the expansion valve where pressure reduction and further cooling takes place before returning to the cooler.

9
Selection Guide

Data Required Cooling Capacity: 537 kW (153 Tons)


To select a YORK YAEP chiller the following information is Water temperature: 12 to 7C (Range = 5 C)
required: 53 to 44 F (Range = 9 F)
Water flow rate: 25.7 l/s (410 gpm)
1. Required cooling capacity. Compressor Power: 173 kW
2. Required refrigerant.
3. Design chilled water entering and leaving temperatures. All values are within the operating limits in Table 1.
4. Design water flow rate if one of the temperatures in item 3 From Pressure Drop Graph (Figure 2). YAEP77WC9C cooler
are unknown. water pressure drop = 30.5 kPa (4.4 psi) at the calculated flow
of 25.7 l/s. (410 gpm)
5. Design condenser entering air temperature. This will
normally be the design summer ambient air temperature
unless location or other factors have an influence. Figure 2 Cooler Water Pressure Drop
6. Altitude above sea level.
180
7. Design cooler fouling factor. 160
140
Note: Items 1, 3 and 4 must be linked by the following 120
formulae: Cooling Capacity (kW) = Range (C) x Flow (litre/ 100 V
sec) x 4.18 Where Range = Entering liquid temperature - U
R Y
Leaving liquid temperature. 80
W
70
60
Selection Method
50
1. Determine the correct size of chiller by selecting the
model which most closely matches the required capacity 40
Pressure Drop (kPa)

at the design conditions of leaving water temperature and


entering air temperature. 30

2. Apply correction factors for fouling factor (Table 2) and


altitude (Table 3) to the capacity and power values from 20
the capacity tables. Ensure the corrected capacity is still
sufficient for requirements. 15

3. Using the corrected capacity of the selected chiller adjust


the design temperature range, or flow rate, to balance the 10
formulae shown in "Data Required".
8
4. Physical and electrical data can now be determined from
Tables 5 and 6. 6 T

5. Always re-check that selections fall within the design 5


limitations specified in Table 1. 4
4 5 6 8 10 15 20 30 40 50 60 70 80 90

Chiller Sample Selection Flow Rate (I/S)

A 50 hertz R22 chiller is required to cool water from 12 to Note: Pressure drop applies to each cooler on 4 Circuit
7 C (53 to 44 F) having a cooling capacity of 525 kW (149 Models (i.e. the total unit flow should be divided by 2 to
Tons) at a design flow rate of 25 l/s (396 gpm). Other design obtain the flow rate through each cooler).
conditions applying are:

Ambient air entering condenser: 35C (95F) Model Pressure Drop Calculation
Fouling Factor: 0.044m C/kW
R Pressure Drop [kPa] = 0.5124 x (Flow Rate [l/s]1.8176)
(0.00025 ftF hr/Btu)
Altitude: Sea level T Pressure Drop [kPa] = 0.2133 x (Flow Rate [l/s]1.7018)

From a cursory examination of capacity Table 4, a model U U Pressure Drop [kPa] = 0.2920 x (Flow Rate [l/s]1.6730)
YAEP77WC9C gives approximately the required capacity: V Pressure Drop [kPa] = 0.2101 x (Flow Rate [l/s]1.6914)

No correction factors apply therefore, after calculating the W Pressure Drop [kPa] = 0.1103 x (Flow Rate [l/s]1.7282)
flow rate, the conditions will be as follows:
Y Pressure Drop [kPa] = 0.0027 x (Flow Rate [l/s]2.4598)

10
Operating Limitations

Table 1
All Models Min. C (F) Max. C (F)

Leaving Chilled Liquid Temperature - R22 Units 4 (39) 12 (54)


Leaving Chilled Liquid Temperature - R407C Units 6 (43) 12 (54)
Chilled Liquid Temperature Difference 3.3 (6) 8 (15)
Air Entering : Standard Units -4 (25) 52 (125)
Electrical Power Supply 380/400/415 V, 3, 50 Hz : V 342 440

1 Circuit Units 2 Circuit Units


55U, 75U,
Model YAEP 06R - 07R 08T - 09T Model YAEP 97V, 99V 77W, 99W
77U
Minimum Cooler Flow l/s (gpm) 4 (64) 6.0 (95) Minimum Cooler Flow l/s (gpm) 7.5 (120) 9.4 (150) 15.8 (250)
Maximum Cooler Flow l/s (gpm) 18 (285) 19 (300) Maximum Cooler Flow l/s (gpm) 36.5 (580) 40.5 (640) 50.7 (805)
Minimum System Volume l (Usg) 1600 (455) 1600 (455) Minimum System Volume l (Usg) 1330 (380) 1620 (460) 2170 (615)

3 Circuit Units 4 Circuit Units


Model YAEP 777Y 997Y 999Y Model YAEP 7575U 9797V, 9999V 9999W

Minimum Cooler Flow l/s (gpm) 25 (400) Minimum Cooler Flow l/s (gpm) 7.5 (120) 9.4 (150) 15.8 (250)
Maximum Cooler Flow l/s (gpm) 36.5 (580) 40.5 (640) 50.7 (805)
Maximum Cooler Flow l/s (gpm) 91 (1445)
Minimum Unit Flow l/s (gpm) 15.0 (242) 18.8 (300) 31.6 (500)
Minimum System Volume l (Usg) 4000 (1140)
Maximum Unit Flow l/s (gpm) 73 (1160) 81 (1280) 101.4 (1610)
Minimum System Volume l (Usg) 2660 (760) 3735 (1065) 6265 (1785)

4 circuit units are fitted with 2 coolers. The table details flow rate for each cooler and total
flow rate for the unit.

Fouling Factors
Table 2
COOLER
Fouling Factor
Capacity Factor Comp. Input Factor
mC/kW ftF hr/Btu
0.018 0.00010 1.000 1.000
0.044 0.00025 0.994 0.998
0.088 0.00050 0.981 0.993
0.176 0.00100 0.958 0.983
0.352 0.00200 0.910 0.960

Altitude Factors
Table 3
Altitude
Capacity Factor Comp. Input Factor
Metres Feet
0 0 1.000 1.000
600 1970 0.987 1.010
1200 3940 0.973 1.020
1800 5905 0.958 1.029
2400 7075 0.943 1.038

11
YAEP R22 Cooling Capacities-Metric Data (C kW/kW)

Table 4a
Leaving Condenser Air Entering Temperature C
Chilled 25 30 35 40 45 46 50
Model
Liquid
C Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
5 225 54 215 57 203 61 193 64 183 67 180 67 172 70
6 233 54 223 58 211 61 201 65 190 68 188 68 179 71
YAEP
7 242 55 232 59 219 62 208 66 198 69 195 69 187 72
06RA7C
10 267 57 256 61 242 65 231 69 220 72 217 73 209 76
12 284 59 273 63 258 67 246 71 234 75 232 75 222 78
5 265 68 253 72 240 76 228 80 216 83 213 84 203 87
6 274 69 263 73 248 77 237 81 224 84 221 85 211 88
YAEP
7 283 70 272 74 257 78 245 82 233 86 230 87 219 90
07RA7C
10 311 73 299 77 284 82 271 86 258 90 255 91 244 94
12 330 75 317 80 302 84 289 89 275 93 272 94 261 98
5 315 79 302 84 287 89 273 94 260 98 257 98 245 102
6 324 80 312 85 295 90 282 95 268 100 266 100 254 104
YAEP
7 335 82 321 87 304 92 291 97 277 102 274 102 263 106
08TA7C
10 363 86 350 91 334 97 319 102 306 107 303 108 292 112
12 383 88 368 94 350 100 334 106 320 111 317 112 306 116
5 382 92 368 99 352 105 339 111 325 116 322 117 310 122
6 393 94 376 100 363 107 349 113 334 118 331 119 319 123
YAEP
7 403 95 388 102 372 108 359 115 344 120 341 121 329 126
09TC9C
10 440 99 426 106 408 113 393 120 378 127 375 128 363 133
12 463 102 449 110 430 117 416 124 399 131 396 132 310 103
5 454 119 438 126 417 132 400 139 383 146 379 147 365 153
6 467 121 451 128 430 135 413 142 395 149 392 150 377 156
YAEP
7 481 123 464 130 443 137 426 145 408 152 404 154 389 160
75UC9C
10 521 129 504 137 482 145 464 153 446 161 442 163 426 169
12 548 134 531 142 508 151 490 159 471 168 467 170 451 177
5 504 138 486 146 417 154 443 162 422 170 418 172 401 178
6 519 141 501 149 476 157 457 165 436 173 432 175 415 182
YAEP
7 534 144 515 152 491 160 471 169 450 177 446 178 429 185
77UC9C
10 579 152 559 161 534 170 513 178 492 187 487 189 469 196
12 609 158 589 167 563 176 541 185 519 194 515 196 496 203
5 569 152 550 160 507 167 481 174 466 180 461 181 442 186
6 584 154 562 162 526 170 498 177 484 184 479 185 459 191
YAEP
7 599 156 575 164 545 173 515 180 502 188 497 190 477 196
77WC9C
10 651 165 626 173 590 182 561 190 550 198 545 200 527 206
12 685 171 660 181 626 190 594 199 581 208 576 210 472 182
5 642 169 617 179 585 189 559 199 531 208 526 210 503 218
6 663 171 638 182 606 192 579 202 551 212 545 214 522 222
YAEP
7 684 174 659 185 626 195 599 206 571 216 565 218 542 226
97VB7C
10 748 183 722 194 688 206 659 216 630 227 624 229 600 238
12 791 189 764 201 729 213 700 224 670 235 664 237 575 216
5 716 198 690 210 657 222 629 234 601 245 595 247 571 256
6 739 201 713 214 679 226 651 238 622 250 616 252 592 261
YAEP
7 762 205 736 218 701 230 673 243 644 254 638 257 613 266
99VB7C
10 832 215 804 229 768 243 739 255 709 268 569 203 549 211
12 878 222 850 237 813 251 783 264 609 208 604 210 583 218

Power (kW) is for compressors only. Power consumption of all fans running: 06RA7C, 07RA7C, 08TA7C = 8.8 kW; 09TC7C, 75UC9C, 77UC9C, 77WC9C = 15.2 kW; 97VB7C, 99VB7C = 17.6 kW

12
YAEP R22 Cooling Capacities-Metric Data (C kW/kW)

Table 4a
Leaving Condenser Air Entering Temperature C
Chilled 25 30 35 40 45 46 50
Model
Liquid
C Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
5 760 183 735 195 702 207 675 219 647 231 641 233 618 243
6 784 186 759 198 725 211 698 223 669 235 664 238 640 247
YAEP
7 808 189 783 202 749 214 721 227 692 240 686 242 663 252
99VD9C
10 880 198 855 212 820 226 789 239 760 252 754 255 729 266
12 928 204 903 219 867 233 835 247 805 261 799 264 627 206
5 802 189 771 200 738 213 707 227 670 240 662 243 631 253
6 830 192 801 204 766 217 733 231 695 244 687 247 656 257
YAEP
7 857 195 831 208 794 221 760 235 721 248 712 251 680 261
99WD9C
10 932 204 903 217 865 232 831 246 790 261 781 264 605 207
12 974 210 950 225 910 239 873 253 836 267 828 270 646 211
5 1000 268 962 284 914 300 873 316 832 331 823 334 788 346
6 1032 272 994 289 945 305 904 321 862 337 853 340 818 352
YAEP
7 1065 277 1026 294 977 310 936 327 893 343 884 346 849 359
997YH7C
10 1164 290 1124 309 1072 327 1029 344 985 361 976 365 853 344
12 1230 300 1189 319 1135 338 1092 356 1046 373 1037 342 908 355
5 1203 284 1150 300 1111 320 1061 338 1003 360 991 365 943 383
6 1244 287 1201 306 1149 326 1100 345 1043 366 1031 370 983 387
YAEP
7 1285 290 1252 312 1188 332 1139 353 1082 372 1071 376 1024 392
999YK9C
10 1399 306 1355 326 1297 348 1250 369 1181 392 1167 396 1010 376
12 1462 312 1425 338 1364 359 1315 380 1267 404 1257 372 1107 390
5 907 237 875 251 835 265 801 278 766 292 758 295 729 306
6 934 241 902 256 860 270 826 284 791 298 783 301 754 312
YAEP
7 961 245 928 260 886 275 852 289 816 304 808 307 778 319
7575UC9C
10 1042 258 1008 274 964 290 929 307 891 322 884 325 853 337
12 1096 267 1062 284 1017 301 980 318 942 336 934 340 902 354
5 1283 337 1233 357 1171 377 1118 397 1063 416 1051 420 1006 435
6 1326 343 1275 363 1211 384 1158 404 1102 424 1090 428 1044 444
YAEP
7 1368 348 1317 369 1252 391 1198 411 1142 431 1130 435 1084 452
9797VB7C
10 1496 366 1443 388 1375 411 1319 433 1260 454 1248 458 1200 475
12 1581 377 1527 401 1457 425 1400 447 1340 469 1328 474 1150 432
5 1432 396 1380 420 1314 444 1259 468 1201 490 1189 494 1142 512
6 1478 403 1426 428 1358 452 1302 476 1244 499 1232 504 1184 522
YAEP
7 1525 410 1471 435 1403 460 1347 485 1288 508 1276 513 1227 532
9999VB7C
10 1663 430 1609 458 1537 485 1479 511 1418 536 1139 406 1098 422
12 1756 444 1700 474 1626 502 1567 528 1219 416 1208 419 1167 435
5 1520 366 1470 390 1404 414 1350 438 1294 462 1282 467 1235 486
6 1568 372 1518 397 1451 422 1396 446 1339 470 1327 475 1280 495
YAEP
7 1616 378 1566 404 1498 429 1441 454 1384 479 1372 484 1325 504
9999VD9C
10 1760 396 1710 424 1639 451 1579 478 1520 505 1507 510 1458 532
12 1856 408 1806 438 1733 466 1671 494 1610 522 1598 528 1254 413
5 1604 378 1542 400 1477 426 1415 454 1340 480 1324 485 1262 506
6 1659 384 1602 408 1532 434 1467 462 1390 488 1375 493 1311 514
YAEP
7 1714 390 1661 416 1588 442 1519 470 1441 496 1425 501 1360 522
9999WD9C
10 1865 408 1806 434 1729 464 1662 492 1580 522 1562 528 1210 414
12 1949 420 1900 450 1819 478 1747 506 1672 534 1656 540 1292 422

Power (kW) is for compressors only. Power consumption of all fans running: 99VD9C, 99WD9C = 30.4 Kw; 997YH7C = 26.4 kW, 999YK9C = 45.6 kW, 7575UC9C = 30.4 kW; 9797VB7C,
9999VB7C = 35.2 kW; 9999VD9C, 9999WD9C = 60.8 kW.

13
YAEP R22 Cooling Capacities-Imperial Data (FTons/kW)

Table 4b
Leaving Condenser Air Entering Temperature F
Chilled 85 95 100 110 115 120 125
Model
Liquid
F Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW
41 61.4 57 57.8 61 54.6 64 53.0 65 51.3 67 49.5 69 47.8 70
44 65.4 58 61.6 62 58.3 66 56.6 67 54.9 69 53.1 71 51.4 73
YAEP 45 66.6 58 62.7 62 59.4 66 57.7 68 56.0 70 54.2 72 52.5 73
06RA7C 47 69.2 59 65.1 63 61.7 67 60.0 69 58.4 71 56.5 73 54.8 75
50 73.1 61 68.9 65 65.4 69 63.7 71 62.0 73 60.1 75 58.4 77
53 77.1 62 72.7 66 69.0 71 67.2 73 65.3 75 63.3 77 61.4 79
41 72.4 72 68.1 76 64.4 80 62.5 82 60.6 84 58.5 86 56.5 88
44 76.8 73 72.4 78 68.6 82 66.6 84 64.7 86 62.5 88 60.5 90
YAEP 45 78.1 74 73.7 79 69.9 83 67.9 85 65.9 87 63.7 89 61.7 91
07RA7C 47 81.0 75 76.5 80 72.6 84 70.5 86 68.5 88 66.3 91 64.2 93
50 85.4 77 80.7 82 76.7 86 74.7 89 72.6 91 70.3 93 68.2 96
53 89.8 79 85.0 84 80.9 89 78.8 91 76.7 93 74.4 96 72.2 98
41 86.4 83 81.5 89 77.3 94 75.2 96 73.0 98 70.6 101 68.4 103
44 90.8 86 85.7 91 81.6 97 79.4 99 77.3 102 74.9 104 72.8 107
YAEP 45 92.1 86 87.0 92 82.8 98 80.7 100 78.6 103 76.2 105 74.1 108
08TA7C 47 95.2 88 90.1 94 85.8 100 83.7 102 81.6 105 79.3 108 77.1 110
50 100.0 91 94.9 97 90.3 103 88.2 105 86.2 108 83.9 111 81.8 114
53 104.4 93 98.8 99 94.0 106 91.8 109 89.6 111 87.2 114 85.0 117
41 105.2 98 100.1 105 95.9 111 93.6 114 91.4 117 89.0 120 86.8 123
44 109.7 100 105.1 108 100.9 114 98.5 117 96.2 120 93.6 123 91.3 126
YAEP 45 111.4 101 106.5 108 102.3 115 100.0 118 97.7 122 95.1 125 92.8 128
09TC9C 47 115.4 103 110.2 110 105.8 117 103.5 121 101.2 124 98.7 127 96.4 131
50 121.5 105 115.9 113 111.3 121 109.0 124 106.7 128 104.3 132 102.0 135
53 127.2 108 121.3 116 116.7 124 114.2 127 111.7 131 109.0 135 86.2 104
41 124.9 125 118.7 132 113.3 140 110.6 144 107.8 147 104.8 151 102.0 155
44 131.3 129 124.9 137 119.5 145 116.7 149 113.8 153 110.8 157 107.9 161
YAEP 45 133.2 130 126.8 138 121.3 146 118.5 150 115.6 154 112.5 159 109.6 163
75UC9C 47 137.4 132 130.8 141 125.3 149 122.4 153 119.6 158 116.4 162 113.5 167
50 143.8 136 137.1 145 131.5 154 128.6 158 125.6 163 122.5 168 119.5 173
53 150.3 140 143.4 150 137.7 159 134.7 164 131.7 169 128.4 173 125.4 178
41 138.6 145 131.4 154 125.3 163 122.1 167 118.9 172 115.4 176 112.2 181
44 145.7 150 138.4 159 132.1 168 128.8 173 125.6 177 122.0 182 118.8 187
YAEP 45 147.8 152 140.4 161 134.1 170 130.8 175 127.5 179 124.0 184 120.7 188
77UC9C 47 152.4 155 144.9 164 138.5 174 135.2 178 131.9 183 128.3 188 124.9 192
50 159.6 160 151.8 170 145.3 179 141.9 184 138.5 189 134.9 194 131.4 199
53 166.8 165 158.8 175 152.1 185 148.6 190 145.1 195 141.4 200 137.9 205
41 156.8 159 144.1 167 136.4 175 133.8 178 131.2 181 127.1 185 123.3 188
44 163.1 163 153.4 172 144.7 180 142.2 184 139.7 188 135.7 193 131.9 197
YAEP 45 165.1 164 155.8 174 147.2 181 144.8 186 142.5 190 138.6 194 134.9 199
77WC9C 47 170.4 167 160.3 177 152.3 185 150.4 189 148.5 193 145.1 197 141.8 201
50 178.8 172 167.8 182 159.3 191 157.2 195 155.1 200 151.4 204 147.9 209
53 187.0 179 176.5 189 167.2 199 164.8 203 162.4 208 158.3 213 131.2 183

Power (kW) is for compressors only. Power consumption of all fans running: 06RA7C, 07RA7C, 08TA7C = 8.8 kW; 09TC7C, 75UC9C, 77UC9C, 77WC9C = 15.2 kW

14
YAEP R22 Cooling Capacities-Imperial Data (FTons/kW)

Table 4b
Leaving Condenser Air Entering Temperature F
Chilled 85 95 100 110 115 120 125
Model
Liquid
F Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW
41 176.0 178 166.4 189 158.1 199 153.8 205 149.4 210 144.8 215 140.4 221
44 186.2 183 176.3 194 167.8 206 163.4 211 159.0 217 154.2 222 149.7 228
YAEP 45 189.2 184 179.2 196 170.7 207 166.2 213 161.8 218 157.0 224 152.5 230
97VB7C 47 195.8 188 185.6 200 177.0 211 172.5 217 167.9 223 163.1 229 158.5 234
50 205.9 193 195.5 206 186.7 217 182.1 223 177.5 229 172.5 235 142.6 193
53 216.1 198 205.4 211 196.4 224 191.7 230 187.0 236 154.6 194 150.6 198
41 197.0 209 186.8 222 178.1 235 173.6 241 169.1 247 164.2 254 159.6 260
44 208.0 215 197.6 229 188.7 242 184.1 249 179.5 255 174.5 262 169.8 268
YAEP 45 211.2 217 200.7 231 191.9 245 187.2 251 182.6 257 177.6 264 172.9 271
99VB7C 47 218.4 221 207.7 236 198.7 249 194.0 256 189.4 263 184.3 270 145.4 207
50 229.5 228 218.5 243 209.4 257 204.6 264 151.8 196 157.7 209 153.8 214
53 240.5 234 229.3 250 220.0 264 215.1 271 170.3 209 166.0 214 162.1 220
41 209.7 194 199.6 207 191.1 220 186.7 227 182.3 233 177.5 240 173.0 247
44 221.3 200 211.0 213 202.2 227 197.7 234 193.2 241 188.3 248 183.8 255
YAEP 45 224.7 201 214.3 215 205.4 229 200.9 236 196.4 243 191.5 250 186.9 257
99VD9C 47 232.2 205 221.7 219 212.6 233 208.0 241 203.4 248 198.5 255 193.9 262
50 243.8 211 233.0 226 223.6 240 219.0 248 214.3 255 209.3 263 204.5 270
53 255.4 216 244.4 232 234.7 247 230.0 255 225.2 262 178.3 196 174.4 209
41 220.1 199 209.9 213 200.1 228 194.2 235 188.3 243 181.9 250 175.9 257
44 234.4 206 223.4 220 212.6 235 206.5 242 200.4 249 193.8 257 187.6 264
YAEP 45 238.6 207 227.3 222 216.4 237 210.2 245 204.0 252 197.2 259 190.9 267
99WD9C 47 247.2 211 235.5 227 224.6 242 218.1 250 211.5 258 204.3 266 160.1 205
50 257.6 216 245.8 232 235.1 248 228.6 256 222.1 264 174.2 205 168.9 211
53 268.8 222 256.7 238 245.5 253 239.5 261 233.5 269 183.9 208 179.0 214
41 274.5 282 259.8 300 247.2 317 240.6 325 234.0 334 226.8 342 220.2 350
44 290.2 290 275.1 309 262.2 327 255.5 335 248.7 344 241.4 353 234.7 362
YAEP 45 294.8 293 279.6 312 266.6 330 259.8 338 253.1 347 245.7 357 238.9 365
997YH7C 47 304.9 298 289.5 318 276.3 336 269.1 345 261.9 353 252.3 360 243.4 366
50 320.7 307 304.8 327 291.4 346 281.9 352 272.5 358 250.9 348 230.7 338
53 336.3 316 320.1 336 306.4 356 296.7 362 287.0 368 264.5 357 243.4 348
41 328.5 298 315.8 320 300.1 340 291.0 352 281.8 365 272.0 378 262.8 390
44 352.8 308 334.4 330 319.0 352 310.0 363 301.0 374 291.3 386 282.2 397
YAEP 45 359.3 311 340.3 333 324.8 356 315.5 367 306.1 378 296.0 389 286.6 400
999YK9C 47 370.9 317 353.2 340 337.7 363 326.4 375 315.0 386 300.7 395 287.4 403
50 386.4 324 368.7 348 353.4 371 339.8 380 326.1 388 297.8 380 271.4 372
53 403.2 333 385.0 357 369.7 380 358.6 390 347.4 399 320.7 391 295.8 383
41 249.8 250 237.3 265 226.7 279 221.1 287 215.6 295 209.6 303 204.0 310
44 262.7 257 249.8 273 239.0 289 233.4 297 227.7 305 221.5 314 215.8 322
YAEP 45 266.4 260 253.5 276 242.7 292 237.0 300 231.2 308 225.1 317 219.3 325
7575UC9C 47 274.8 265 261.6 282 250.6 298 244.9 307 239.1 315 232.9 325 227.0 333
50 287.7 273 274.2 290 263.0 308 257.1 317 251.3 326 244.9 336 239.0 346
53 300.6 281 286.8 299 275.3 318 269.3 328 263.3 337 256.9 347 250.8 355

Power (kW) is for compressors only. Power consumption of all fans running: 99VD9C, 99WD9C = 30.4kW; 997YH7C = 26.4 kW; 999YK9C = 45.6 kW; 7575UC9C = 30.4kW.

15
YAEP R22 Cooling Capacities-Imperial Data (FTons/kW)

Table 4b
Leaving Condenser Air Entering Temperature F
Chilled 85 95 100 110 115 120 125
Model
Liquid
F Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW
41 352.1 355 332.8 377 316.2 399 307.5 409 298.9 420 289.5 431 280.8 441
44 372.4 365 352.6 389 335.6 411 326.8 422 318.0 433 308.4 445 299.5 456
YAEP 45 378.4 369 358.4 392 341.3 415 332.5 426 323.6 437 313.9 449 305.0 460
9797VB7C 47 391.5 375 371.2 400 353.9 423 344.9 434 335.9 445 326.1 457 317.0 469
50 411.9 386 391.1 411 373.3 435 364.1 447 354.9 458 344.9 471 285.2 386
53 432.2 397 410.9 423 392.8 447 383.4 459 374.0 471 309.2 388 301.2 396
41 393.9 418 373.6 444 356.2 470 347.2 482 338.2 494 328.4 507 319.2 519
44 416.0 430 395.1 458 377.5 485 368.2 498 359.0 510 349.0 524 339.7 536
YAEP 45 422.5 434 401.5 462 383.7 489 374.5 502 365.2 515 355.1 528 345.7 541
9999VB7C 47 436.8 443 415.4 471 397.5 499 388.1 512 378.7 525 368.5 539 290.8 414
50 458.9 456 437.0 485 418.7 513 409.2 527 303.6 391 315.3 417 307.5 428
53 481.0 469 458.6 499 440.0 528 430.2 542 340.6 417 332.1 429 324.1 439
41 419.3 388 399.2 414 382.2 440 373.3 454 364.5 467 354.9 481 346.0 494
44 442.6 399 421.9 427 404.3 454 395.3 468 386.4 482 376.6 496 367.5 510
YAEP 45 449.4 402 428.6 430 410.8 458 401.8 472 392.8 486 383.0 501 373.9 514
9999VD9C 47 464.4 410 443.3 439 425.1 467 416.0 481 406.9 495 397.0 510 387.7 524
50 487.6 422 466.1 451 447.3 481 437.9 495 428.6 510 418.5 526 409.1 540
53 510.9 433 488.8 464 469.5 494 460.0 510 450.5 525 356.6 391 348.7 417
41 440.2 398 419.8 426 400.2 457 388.3 471 376.5 485 363.7 500 351.8 514
44 468.8 411 446.7 440 425.3 470 413.0 485 400.8 499 387.6 514 375.3 528
YAEP 45 477.3 415 454.7 444 432.9 475 420.4 489 407.9 504 394.4 519 381.9 533
9999WD9C 47 494.5 423 471.0 454 449.3 485 436.1 500 422.9 516 408.7 532 320.3 411
50 515.2 431 491.6 464 470.3 495 457.3 512 444.3 528 348.4 409 337.8 421
53 537.7 445 513.4 476 490.9 507 479.0 522 467.0 538 367.7 416 357.9 427

Power (kW) is for compressors only. Power consumption of all fans running: 9797VB7C, 9999VB7C = 35.2 kW; 9999VD9C, 9999WD9C = 60.8 kW.

16
YAEP R407C Cooling Capacities-Metric Data (C kW/kW)

Table 4c
Leaving Condenser Air Entering Temperature C
Chilled 25 30 35 40 45 48 50
Model
Liquid
C Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
6 54 212 58 198 61 186 64 173 66 165 68 124 47 243
7 232 55 220 59 206 62 193 65 181 68 173 69 130 48
YAEP
8 240 56 228 60 214 63 201 66 188 69 180 71 137 49
06RA7B
10 257 58 245 62 230 66 217 69 204 72 196 74 149 51
12 273 60 261 64 246 68 233 72 220 75 212 78 161 54
6 263 70 249 73 233 77 219 80 205 83 196 84 148 58
7 272 71 259 74 243 78 228 81 213 84 204 86 155 60
YAEP
8 282 72 268 76 252 80 237 83 222 86 213 88 161 61
07RA7B
10 302 75 288 79 270 83 255 87 240 90 230 92 175 64
12 321 77 307 82 289 86 273 90 257 94 248 96 188 67
6 324 77 309 83 290 87 273 92 256 96 246 99 193 75
7 335 79 318 84 300 88 283 94 265 98 254 101 200 77
YAEP
8 345 80 329 86 309 90 293 96 275 100 264 103 208 79
08TC7B
10 366 83 349 89 330 94 312 100 294 105 282 108 222 82
12 387 86 371 92 350 98 332 104 312 109 300 112 237 86
6 382 94 366 100 347 106 330 112 312 117 302 120 238 91
7 393 96 376 102 356 108 340 114 322 119 312 122 247 93
YAEP
8 402 98 387 104 367 110 349 116 332 122 322 125 255 95
09TC9B
10 422 101 407 108 386 115 369 121 351 127 340 131 269 100
12 443 105 427 112 407 119 388 126 371 133 291 102 285 104
6 414 104 398 110 377 116 356 122 337 127 325 130 187 67
7 428 106 412 112 389 119 368 125 349 130 337 133 194 69
YAEP
8 442 108 425 115 402 122 381 128 361 133 349 136 201 71
55UC9B
10 470 112 452 120 428 128 406 134 386 140 374 143 216 74
12 498 116 479 125 454 134 432 140 411 146 253 76 230 78
6 459 127 439 133 413 139 393 145 305 120 294 123 144 63
7 474 129 454 136 428 142 407 148 316 124 305 126 149 64
YAEP
8 490 132 469 139 442 146 421 152 326 127 315 130 154 66
75UC9B
10 521 138 500 145 471 153 448 160 348 133 336 137 164 69
12 553 144 530 151 501 160 476 167 370 140 357 143 174 73
6 533 140 515 146 488 152 460 158 431 165 413 169 293 117
7 559 143 539 149 511 156 482 162 453 169 435 174 309 120
YAEP
8 584 146 563 152 534 159 505 166 475 174 457 178 325 123
77UF7B
10 636 151 611 159 579 167 556 174 519 182 496 187 351 129
12 687 157 658 165 625 174 595 182 563 191 544 196 387 136
6 582 145 554 152 524 159 499 166 466 174 446 179 316 124
7 602 148 574 156 543 163 517 170 484 178 464 183 329 127
YAEP
8 622 151 594 159 562 167 534 174 502 183 481 188 341 130
77WF7B
10 663 157 633 166 600 174 570 183 537 191 516 197 367 136
12 704 163 673 173 638 182 605 191 572 200 551 205 392 142
6 679 165 650 175 617 185 588 193 558 202 539 207 405 151
7 701 168 672 178 641 188 609 197 576 206 555 211 417 154
YAEP
8 723 171 695 181 664 192 629 201 594 210 572 215 429 158
97VD7B
10 767 177 740 88 710 199 670 209 629 219 604 225 452 165
12 811 183 786 195 756 207 712 217 666 228 637 234 476 171

Power (kW) is for compressors only. Power consumption of all fans running: 06RA7B, 07RA7B, 08TC7B = 8.8 kW; 09TC9B, 55UC9B, 75UC9B = 15.2 kW; 77UF7B, 77WF7B = 13.2 kW; 97VC7B,
99VD7B = 17.6 kW.

17
YAEP R407C Cooling Capacities-Metric Data (C kW/kW)

Table 4c
Leaving Condenser Air Entering Temperature C
Chilled 25 30 35 40 45 48 50
Model
Liquid
C Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
6 754 195 724 208 687 220 655 230 623 242 602 249 465 191
7 777 199 747 212 709 224 677 235 645 247 624 254 483 194
YAEP
8 799 202 769 216 731 229 699 239 667 252 646 259 500 198
99VD7B
10 845 210 814 223 775 237 743 249 711 261 690 269 534 205
12 890 217 858 231 820 246 788 258 611 203 595 209 569 213
6 792 193 763 205 725 217 694 230 638 237 603 241 470 183
7 815 197 786 209 748 222 716 235 660 242 625 246 488 187
YAEP
8 838 200 809 213 770 226 738 239 682 247 648 252 506 191
99WD9B
10 884 208 856 222 814 236 781 249 726 257 692 262 542 199
12 930 215 903 230 858 245 825 258 770 267 596 204 578 207
6 884 213 841 223 798 234 760 244 713 256 684 262 518 182
7 915 217 873 228 829 239 787 250 740 262 711 269 539 186
YAEP
8 946 221 904 233 860 244 814 256 767 268 738 275 560 191
777YG7B
10 1007 229 967 242 922 255 869 267 821 281 791 288 601 200
12 1069 237 1030 252 984 266 923 279 875 293 844 301 643 209
6 1077 266 1035 281 982 297 937 312 891 327 862 335 674 246
7 1109 271 1068 287 1016 303 969 319 922 334 894 343 700 251
YAEP
8 1142 276 1101 292 1049 309 1000 325 952 341 922 350 721 256
997YJ7B
10 1212 286 1169 304 1116 321 1063 339 840 355 703 365 488 267
12 1277 296 1234 315 1183 333 1125 352 888 369 536 273 516 278
6 1188 290 1144 308 1088 326 1042 345 990 363 958 374 759 286
7 1222 295 1179 314 1121 332 1074 352 1023 371 991 382 786 292
YAEP
8 1257 300 1214 320 1154 339 1107 359 1056 378 1025 390 813 298
999YK9B
10 1326 311 1284 332 1221 353 1172 373 1122 393 1091 405 867 310
12 1395 323 1348 345 1287 368 1237 387 1185 407 842 312 916 317
6 918 253 878 265 826 277 786 289 610 241 589 247 287 125
7 949 259 908 271 855 284 813 296 631 247 610 253 297 128
YAEP
8 980 265 938 277 884 291 841 304 653 254 630 260 307 132
7575UC9B
10 1043 276 1000 290 943 305 897 319 696 266 672 273 328 139
12 1107 288 1061 302 1002 319 953 334 740 279 714 286 348 146
6 1359 330 1299 350 1235 369 1176 386 1115 403 1078 413 810 302
7 1402 336 1345 356 1281 376 1217 394 1151 411 1110 422 834 309
YAEP
8 1446 342 1390 363 1327 384 1258 402 1187 420 1143 431 857 316
9797VD7B
10 1534 353 1481 176 1420 398 1341 418 1259 437 1208 449 904 329
12 1621 365 1572 389 1513 413 1424 434 1331 455 1274 468 951 343
6 1508 390 1448 416 1374 440 1311 460 1245 484 1205 498 930 381
7 1553 397 1493 424 1418 448 1355 469 1289 494 1249 508 965 389
YAEP
8 1599 405 1538 431 1462 457 1399 478 1333 503 1293 518 1000 396
9999VD7B
10 1690 419 1627 446 1551 474 1487 497 1421 522 1381 538 1069 411
12 1781 434 1717 462 1639 492 1575 516 1222 407 1189 418 1138 426
6 1583 386 1525 410 1451 434 1389 460 1276 474 1207 482 939 366
7 1630 393 1572 418 1495 443 1432 469 1320 484 1251 493 975 374
YAEP
8 1676 400 1619 426 1539 452 1476 478 1364 494 1295 503 1012 382
9999WD9B
10 1768 415 1713 443 1628 471 1562 497 1452 514 1384 524 1084 398
12 1861 430 1806 460 1716 490 1649 516 1540 534 1193 409 1156 414

Power (kW) is for compressors only. Power consumption of all fans running: 99WD9B = 30.2 kW; 777YG7B = 22kW 997YJ7B = 26.4 kW 999YK9B = 45.6 kW 7575UC9B = 30.2 KW; 9797VD7B,
9999VD7B = 35.2 kW; 9999WD9B = 60.4 kW.

18
YAEP R407C Cooling Capacities-Imperial Data (FTons/kW)

Table 4d
Leaving Condenser Air Entering Temperature F
Chilled 85 95 100 110 115 120 125
Model
Liquid
F Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW
43 60.8 57 56.5 61 50.6 65 49.6 66 48.6 67 47.1 68 35.0 48
44 62.2 58 57.9 62 51.9 66 50.9 67 49.9 68 48.4 69 36.0 48
YAEP 45 63.4 58 59.0 62 53.0 67 52.1 68 51.1 69 49.5 70 36.9 49
06RA7B 47 65.9 60 61.5 64 55.5 69 54.5 70 53.5 70 52.0 72 38.8 50
50 69.9 61 65.4 66 59.3 71 58.3 72 57.3 73 55.8 74 41.6 52
53 73.8 63 69.3 68 63.2 74 62.1 75 61.1 76 59.6 77 44.5 54
43 71.5 73 66.6 77 59.8 82 58.7 82 57.6 83 55.9 85 41.6 59
44 73.1 74 68.2 78 61.4 83 60.2 84 59.1 84 57.3 86 42.7 60
YAEP 45 74.5 74 69.5 78 62.6 84 61.5 85 60.3 85 58.6 87 43.6 61
07RA7B 47 77.5 76 72.4 80 65.4 86 64.2 87 63.1 88 61.3 89 45.7 62
50 82.2 78 76.9 83 69.7 89 68.5 90 67.3 91 65.5 92 48.9 65
53 86.8 81 81.4 85 74.0 92 72.8 93 71.5 94 69.6 96 52.1 67
43 87.9 82 82.4 87 77.6 92 74.8 95 71.9 98 68.9 102 54.1 77
44 89.8 83 84.4 88 79.6 93 76.6 96 73.6 99 70.5 104 55.4 78
YAEP 45 91.2 84 85.7 89 81.0 94 77.9 97 74.9 101 71.7 105 56.4 79
08TC7B 47 94.5 86 88.8 91 84.0 96 81.0 100 77.9 103 74.8 108 58.8 81
50 99.4 88 93.7 94 88.7 100 85.6 103 82.4 107 79.1 112 62.2 84
53 104.3 91 98.3 97 93.2 103 89.9 107 86.6 110 83.2 116 65.5 86
43 104.3 100 98.6 106 93.7 112 90.7 115 87.8 119 84.7 124 66.8 92
44 106.2 101 100.5 108 95.6 113 92.7 117 89.8 120 86.7 126 68.4 94
YAEP 45 107.6 102 101.9 109 97.0 114 94.1 118 91.2 122 88.2 127 69.5 95
09TC9B 47 110.9 104 105.2 111 100.1 117 97.2 121 94.2 125 91.2 130 71.9 98
50 115.8 108 109.8 115 104.8 121 101.8 125 98.7 130 95.6 136 75.4 101
53 120.4 111 114.5 118 109.2 125 106.2 130 103.2 134 81.0 105 79.0 105
43 113.3 110 107.1 116 101.1 122 97.8 126 94.6 129 91.2 134 52.3 68
44 116.0 112 109.6 118 103.6 124 100.3 128 97.0 131 93.6 136 53.7 69
YAEP 45 117.9 113 111.5 120 105.4 126 102.1 129 98.8 133 95.4 138 54.7 70
55UC9B 47 122.1 116 115.5 123 109.3 129 106.0 133 102.7 136 99.2 142 57.0 72
50 128.7 120 121.7 128 115.5 134 112.1 138 108.7 142 105.1 147 60.4 75
53 134.8 124 127.5 133 121.2 139 117.8 143 114.4 147 57.2 75 63.7 78
43 124.9 132 117.4 139 111.2 144 98.4 133 85.7 122 82.7 127 40.2 64
44 127.9 134 120.3 141 113.9 147 100.9 136 87.8 125 84.7 129 41.2 65
YAEP 45 130.1 136 122.4 143 115.9 148 102.6 137 89.3 126 86.2 131 41.9 66
75UC9B 47 134.8 139 127.0 147 120.2 153 106.4 141 92.7 130 89.4 135 43.5 68
50 142.2 145 134.0 153 126.9 159 112.4 147 97.9 135 94.4 141 45.9 70
53 149.2 150 140.7 158 133.2 165 118.0 153 102.7 141 99.1 147 48.2 73
43 146.7 146 138.7 152 130.6 158 125.8 163 120.9 168 115.9 175 82.1 119
44 151.4 148 143.3 155 135.1 161 130.2 166 125.3 171 120.2 178 85.2 121
YAEP 45 154.8 150 146.5 156 138.3 163 133.3 168 128.4 173 123.3 181 87.4 123
77UF7B 47 162.2 153 153.6 160 145.5 167 140.4 173 135.2 178 129.8 186 92.0 126
50 173.8 158 164.7 167 157.9 174 151.7 180 145.5 185 139.0 193 98.3 131
53 184.6 164 175.1 173 166.7 181 161.2 187 155.7 193 150.0 202 106.5 137

Power (kW) is for compressors only. Power consumption of all fans running: 06RA7B, 07RA7B, 08TC7B = 8.8 kW; 09TC9B, 55UC9B, 75UC9B = 15.2 kW; 77UF7B, 77WF7B = 13.2 kW; 97VD7B,
99VD7B = 17.6 kW.

19
YAEP R407C Cooling Capacities-Imperial Data (FTons/kW)

Table 4d
Leaving Condenser Air Entering Temperature F
Chilled 85 95 100 110 115 120 125
Model
Liquid
F Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW
43 157.6 152 149.1 159 141.7 166 136.2 172 130.7 177 125.0 185 88.4 126
44 161.6 154 152.8 162 145.3 169 139.7 175 134.2 180 128.4 189 90.9 128
YAEP 45 164.4 156 155.5 164 147.8 171 142.2 177 136.7 183 130.9 191 92.7 130
77WF7B 47 170.6 160 161.5 168 153.3 176 147.7 181 142.2 187 136.4 196 96.7 133
50 180.2 166 170.6 174 161.9 183 156.3 189 150.7 195 144.9 204 102.7 138
53 189.3 171 179.2 180 169.9 189 164.3 196 158.7 202 152.7 210 108.4 143
43 184.9 175 175.5 185 167.0 193 161.9 199 156.8 205 151.5 213 113.5 153
44 189.4 177 180.1 187 171.1 196 165.7 202 160.2 208 154.6 217 115.8 156
YAEP 45 192.6 179 183.4 189 174.0 198 168.4 204 162.7 210 156.8 219 117.4 157
99VD7B 47 199.7 167 190.7 193 180.5 202 174.3 209 168.2 215 161.8 224 121.0 161
50 210.7 90 201.9 199 190.4 209 183.5 216 176.6 223 169.4 232 126.6 167
53 221.0 173 212.5 205 199.8 216 192.2 223 184.5 230 176.6 240 131.9 173
43 206.1 208 195.3 220 186.1 230 180.6 239 175.1 247 169.4 259 133.6 193
44 210.5 210 199.7 223 190.5 233 185.0 242 179.5 250 173.8 262 137.1 196
YAEP 45 213.7 212 202.8 225 193.6 236 188.1 244 182.6 253 176.9 265 139.6 198
99VD7B 47 220.7 216 209.7 230 200.6 241 195.0 249 189.5 258 183.7 270 145.0 202
50 231.5 223 220.4 237 211.2 249 205.7 258 200.1 266 155.5 209 153.5 208
53 241.7 229 230.5 244 221.3 256 194.7 231 168.1 206 163.5 215 161.4 215
43 217.0 205 206.3 217 197.1 230 187.6 235 178.1 240 168.2 247 131.5 187
44 221.6 208 210.7 220 201.4 233 192.0 238 182.5 243 172.7 251 135.1 190
YAEP 45 225.0 210 213.8 223 204.5 236 195.1 241 185.6 246 175.8 253 137.6 192
99WD9B 47 232.3 214 220.7 228 211.3 241 201.9 246 192.5 252 182.8 260 143.2 196
50 243.6 221 231.4 236 221.8 249 212.5 255 203.2 260 193.5 269 151.8 203
53 254.3 228 241.5 243 231.7 256 222.5 262 213.2 269 162.9 208 159.9 210
43 241.3 222 227.8 234 208.0 252 204.4 255 200.8 258 195.3 263 145.8 185
44 246.7 225 233.1 237 212.6 256 209.0 259 205.4 262 199.8 267 149.2 188
YAEP 45 251.1 228 237.5 240 216.4 259 212.8 262 209.2 265 203.6 270 152.1 190
777YG7B 47 260.9 233 247.2 246 224.9 266 221.2 269 217.6 272 212.0 277 158.5 195
50 276.1 241 262.2 255 238.0 276 234.3 280 230.6 283 224.9 288 168.4 203
53 291.3 249 277.2 264 251.1 286 247.3 290 243.6 294 237.8 299 178.3 211
43 296.5 280 280.2 297 258.7 322 255.2 326 251.6 330 246.1 336 189.6 250
44 302.0 283 286.0 301 264.1 326 260.5 330 256.9 334 251.4 340 193.8 253
YAEP 45 306.7 286 290.7 304 268.4 330 264.8 334 261.3 338 255.7 344 197.1 256
997YJ7B 47 317.1 292 301.2 311 273.0 338 267.3 342 261.5 346 264.7 352 192.2 262
50 333.5 302 317.4 321 260.3 349 243.2 354 226.1 358 199.8 365 136.7 271
53 349.4 312 333.6 331 273.2 361 255.2 366 237.2 370 159.5 287 143.3 281
43 327.5 306 310.3 326 287.4 358 283.5 362 279.5 367 273.4 375 213.2 291
44 333.5 310 316.0 330 293.0 362 289.1 367 285.1 372 279.1 379 217.8 294
YAEP 45 338.4 313 320.7 334 297.7 366 293.8 371 289.8 376 283.8 383 221.6 297
999YK9B 47 349.4 320 331.0 341 308.0 374 304.1 379 300.2 384 294.2 392 229.9 304
50 366.4 330 347.1 353 323.8 386 320.0 392 316.2 397 310.3 405 242.8 314
53 382.0 341 363.2 365 339.2 398 335.2 403 331.2 408 250.0 326 254.4 321

Power (kW) is for compressors only. Power consumption of all fans running: 99WD9B = 30.2 kW; 777YG7B = 22 kW 997YJ7B = 26.4 kW 999YK9B = 45.6 kW 7575UC9B, = 30.2 KW; 9797VD7B,
9999VD7B = 35.2 kW; 9999WD9B = 60.4 kW.

20
YAEP R407C Cooling Capacities-Imperial Data (FTons/kW)

Table 4d
Leaving Condenser Air Entering Temperature F
Chilled 85 95 100 110 115 120 125
Model
Liquid
F Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power Cool Power
Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW Tons kW
43 249.7 265 234.9 277 222.4 288 196.9 266 171.4 245 165.3 254 80.4 127
44 255.8 269 240.7 282 227.9 293 201.7 271 175.6 249 169.5 259 82.4 129
YAEP 45 260.1 272 244.8 285 231.8 297 205.2 275 178.7 252 172.4 262 83.8 131
7575UC9B 47 269.7 279 254.0 293 240.4 305 212.9 282 185.3 260 178.8 270 87.0 135
50 284.5 289 268.1 305 253.9 318 224.8 294 195.7 271 188.9 282 91.9 141
53 298.4 299 281.4 316 266.5 330 236.0 306 205.4 281 198.3 293 96.4 146
43 369.8 350 351.1 369 334.1 386 323.8 398 313.6 410 302.9 427 227.0 307
44 378.8 354 360.3 374 342.2 392 331.3 404 320.5 416 309.2 433 231.5 312
YAEP 45 385.2 357 366.9 378 348.0 396 336.7 408 325.4 420 313.6 438 234.8 315
9797VD7B 47 399.4 335 381.3 386 360.9 405 348.6 417 336.3 430 323.6 448 242.1 322
50 421.4 179 403.8 398 380.8 418 367.0 432 353.1 445 338.8 465 253.2 334
53 442.1 347 424.9 410 399.5 431 384.3 445 369.1 460 353.2 480 263.8 345
43 412.2 415 390.6 440 372.3 460 361.3 477 350.2 494 338.7 518 267.1 387
44 421.1 421 399.4 446 381.0 467 370.0 484 359.0 500 347.5 525 274.1 392
YAEP 45 427.4 425 405.7 450 387.3 472 376.3 488 365.2 505 353.8 530 279.1 396
9999VD7B 47 441.4 433 419.5 460 401.1 482 390.0 499 379.0 516 367.5 541 290.0 404
50 463.1 445 440.9 474 422.4 498 411.3 515 400.3 532 311.0 418 307.0 417
53 483.4 458 461.1 488 442.5 513 389.4 462 336.2 411 326.9 431 322.8 429
43 434.0 410 412.5 434 394.2 460 375.2 470 356.2 480 336.5 494 263.1 374
44 443.3 415 421.3 440 402.9 467 383.9 477 365.0 487 345.3 501 270.1 379
YAEP 45 449.9 419 427.6 445 409.1 471 390.2 482 371.3 492 351.7 507 275.2 384
9999WD9B 47 464.6 428 441.4 455 422.6 482 403.9 492 385.1 503 365.6 519 286.3 393
50 487.2 443 462.8 471 443.6 498 425.0 509 406.4 521 387.1 538 303.5 407
53 508.6 456 483.0 486 463.4 513 444.9 525 426.5 537 325.9 416 319.7 420

Power (kW) is for compressors only. Power consumption of all fans running: 99WD9B = 30.2 kW; 777YG7B = 22 kW 997YJ7B = 26.4 kW 999YK9B = 45.6 kW 7575UC9B, = 30.2 KW; 9797VD7B,
9999VD7B = 35.2 kW; 9999WD9B = 60.4 kW.

21
Physical data - YAEP R22 Units

Table 5a
1 Circuit 2 Circuit
YAEP
06RA7C 07RA7C 08TA7C 09TC9C 75UC9C 77UC9C 77WC9C 97VB7C 99VB7C 99VD9C 99WD9C
Nom. Capacity @ 7C/35C kW 219 257 304 372 443 491 545 626 701 749 794
Unit No. of Capacity Steps (Std.) 2 2 3 3 4 4 4 5 6 6 6
No. of Capacity Steps (Opt.) 3 3 4 4 5 6 6 7 8 8 8
Number of Compressors 1 1 1 1 2 2 2 2 2 2 2
Comp. Cylinders per Compressor 6 6 8 8 6/4 6 6 8/6 8 8 8
Oil Capacity per Comp. l 11 11 11 11 11 11 11 11 11 11 11
NumberofCoolers 1 1 1 1 1 1 1 1 1 1 1
Cooler RefrigerantCircuits(each) 1 1 1 1 2 2 2 2 2 2 2
Water Capacity (each) l 61 61 90 90 135 135 205 150 150 150 205
Face Area m2 11.9 11.9 11.9 11.9 11.9 11.9 11.9 23.8 23.8 23.8 23.8
Cond. Quantity 4 4 4 4 4 4 4 8 8 8 8
and
Fans Power (each) kW 2.2 2.2 2.2 3.8 3.8 3.8 3.8 2.2 2.2 3.8 3.8
3
Total Airflow m /s 30 30 30 35 35 35 35 61 61 70 70
Refrigerant Charge Systems 1 kg 61 61 62 63 32 32 46 47 47 54 61
Refrigerant Charge Systems 2 kg 32 32 46 47 47 54 61
Refrigerant Charge Systems 3 kg
Refrigerant Charge Systems 4 kg
Ship (Main) kg 2314 2314 2881 3132 3875 3958 4465 4929 5176 5582 5895
Alumini
Ship (Aux.) kg
um Fins
Operating kg 2375 2375 2971 3222 4010 4093 4670 5079 5326 5732 6100
Weight
Ship (Main) kg 2501 2501 3071 3422 4165 4248 4755 5309 5556 6162 6475
Copper
Ship (Aux.) kg
Fins
Operating kg 2562 2562 3161 3512 4300 4383 4960 5459 5706 6312 6680
Length mm 2969 2969 2969 2969 2969 2969 2969 5703 5703 5703 5703
Dims. Width mm 2241 2241 2241 2241 2241 2241 2241 2241 2241 2241 2241
Height mm 2490 2490 2490 2490 2490 2490 2490 2490 2490 2490 2490
Sound Power Level dBA 100 100 100 102 100 104 104 104 104 106 106

22
Physical data - YAEP R22 Units

3 Circuit 4 Circuit
YAEP
997YH7C 999YK9C 7575UC9C 9797VB7C 9999VB7C 9999VD9C 9999WD9C
Nom. Capacity @ 7C/35C kW 977 1188 886 1252 1403 1498 1588
Unit No. of Capacity Steps (Std.) 8 9 8 10 12 12 12
No. of Capacity Steps (Opt.) 11 12 10 12 16 16 16
Number of Compressors 3 3 4 4 4 4 4
Comp. Cylinders per Compressor 8/8/6 8 6/4 8/6 8 8 8
Oil Capacity per Comp. l 11 11 11 11 11 11 11
NumberofCoolers 1 1 2 2 2 2 2
Cooler RefrigerantCircuits(each) 3 3 2 2 2 2 2
Water Capacity (each) l 530 530 135 150 150 150 205
Face Area m2 35.7 35.7 23.8 47.6 47.6 47.6 47.6
Cond. Quantity 12 12 8 16 16 16 16
and
Fans Power (each) kW 2.2 3.8 2.2 2.2 2.2 3.8 3.8
3
Total Airflow m /s 90 105 61 122 122 139 139
Refrigerant Charge Systems 1 kg 60 67 32 47 47 54 54
Refrigerant Charge Systems 2 kg 60 67 32 47 47 54 54
Refrigerant Charge Systems 3 kg 65 71 32 47 47 54 54
Refrigerant Charge Systems 4 kg 32 47 47 54 54
Ship (Main) kg 8317 9424 3379 4929 5176 5582 5895
Alumini
Ship (Aux.) kg 3379 4929 5176 5582 5895
um Fins
Operating kg 8841 9948 7028 10157 10652 11463 12200
Weight
Ship (Main) kg 9408 10818 4165 5310 5556 6162 6475
Copper
Ship (Aux.) kg 4165 5310 5556 6162 6475
Fins
Operating kg 9932 11342 8600 10920 11412 12623 13360
Length mm 8901 8901 6128 11705 11705 11705 11705
Dims. Width mm 2241 2241 2241 2241 2241 2241 2241
Height mm 2490 2490 2490 2490 2490 2490 2490
Sound Power Level dBA 107 107 107 107 107 109 109

23
Electrical Data - YAEP R22 Units

Table 6a
Single Point Input (to each panal) - Connection to Disconnect Switcth (Std.) or Terminal Block (Opt.)

YAEP Supply for Panel KW Panel Nominal Amps Panel Maximum Amps Panel Max Start Amps
Model Panel(s) Nom. Max. 380 V 400 V 415 V 342 V 380 V 400 V 415 V 380 V 400 V 415 V
06RA7C Main 71 91 131 131 130 184 156 155 154 458 482 508
07RA7C Main 87 115 167 167 166 231 212 211 209 549 575 600
08TA7C Main 101 125 194 194 193 244 225 225 224 689 721 752
09TC9C Main 123 150 230 228 225 297 274 271 267 689 721 752
75UC9C, 7575UC9C Main & Auxiliary 153 195 287 284 281 387 354 349 343 698 724 742
77UC9C Main 175 219 328 325 321 451 394 405 399 746 780 799
77WC9C Main 187 227 350 345 341 451 410 405 399 754 780 799
97VB7C, 9797VB7C Main & Auxiliary 213 259 400 398 395 515 477 474 470 901 936 961
99VB7C, 9999VB7C Main & Auxiliary 248 288 457 454 450 568 529 526 522 953 988 1,013
99VD9C, 9999VD9C Main & Auxiliary 250 300 461 456 450 594 549 542 534 963 996 1,019
99WD9C, 9999WD9C Main & Auxiliary 244 300 457 446 438 594 549 542 534 963 996 1,019
Main 248 288 457 454 450 528 529 526 522 953 988 1,013
997YH7C
Auxiliary 89 115 171 171 170 231 212 212 209 549 578 600
Main 252 300 461 456 450 594 549 542 534 963 996 1,019
999YK9C
Auxiliary 126 150 230 228 225 297 274 271 267 689 725 752

Note:
Panel = Power required for each panel with a single power input, data includes compressors and asociated fans.
System 1 or 1 & 2 = Main Panel. System 3 or 3 & 4 = Auxillary Panel. System = Each Independent (system) refrigerant circuit.
One and two circuit units have a one panel, three and four circuit units have two panels each requiring a separate power supply.
Panel maximum start amps includes 1 compressor and all associated fans running plus second compressor starting.

Multi Point Input to each system - Connection to Fuse Block (Opt.) or Terminal Block (Opt.)

YAEP Supply for System KW System Nominal Amps System Maximum Amps Parts Wind Inrush
Model System(s) Nom. Max. 380 V 400 V 415 V 342 V 380 V 400 V 415 V 380 V 400 V 415 V
06RA7C 1 71 91 131 131 130 184 156 155 154 458 482 508
07RA7C 1 87 115 167 167 166 231 212 211 209 549 575 600
08TA7C 1 101 125 194 194 193 244 225 225 224 689 721 752
09TC9C 1 123 150 230 228 225 297 274 271 267 689 721 752
1, & 3 88 114 164 162 161 226 205 202 200 549 578 600
75UC9C, 7575UC9C
2, & 4 66 82 123 121 119 162 149 146 142 356 376 390
77UC9C 1&2 88 110 164 162 160 226 197 202 199 549 578 600
77WC9C 1&2 94 114 175 172 170 226 205 202 199 549 578 600
1, & 3 124 144 228 227 225 284 264 263 261 689 725 752
97VB7C, 9797VB7C
2, & 4 89 115 171 171 170 231 212 211 209 549 578 600
99VB7C, 9999VB7C 1 & 2, 3 & 4 124 144 228 227 225 284 264 263 261 689 725 752
99VD9C, 9999VD9C 1 & 2, 3 & 4 125 150 230 228 225 297 274 271 267 689 725 752
99WD9C, 9999WD9C 1 & 2, 3 & 4 122 150 228 223 219 297 274 271 267 689 725 752
1&2 124 144 228 227 225 264 264 263 261 689 725 752
997YH7C
3 89 115 171 171 170 231 212 212 209 549 578 600
1&2 126 150 230 228 225 297 274 271 267 689 725 752
999YK9C
3 126 150 230 228 225 297 274 271 267 689 725 752

Note:
System = Power required for each individual system (refrigerant circuit including compressor and asociated fans)
Data for models 75UC9C, 7575UC9C, 97VB7C, 9797VB7C, 997YH7C 997YH7C, 999YK9C is given in two rows, with largest system first.
Part wind inrush is the compressor starting.

24
Electrical Data - YAEP R22 Units

Total Unit Data 3 & 4 Circuit Models only (Refer to Single Point Input for 1 and 2 Circuit Unit Data)

YAEP Total Supply for Unit KW Unit Nominal Amps Unit Maximum Amps Unit Max Start Amps
Model systems Nom. Max. 380 V 400 V 415 V 342 V 380 V 400 V 415 V 380 V 400 V 415 V
997YH7C 1,2 & 3 336 402 628 624 619 759 741 737 730 1,166 1,200 1,222
999YK9C 1,2 & 3 376 451 691 683 675 892 823 812 801 1,238 1,267 1,286
7575UC9C 1, 2, 3 & 4 306 390 575 568 562 774 709 698 686 1,053 1,073 1,085
9797VB7C 1, 2, 3 & 4 425 517 800 795 789 1030 954 947 939 1,378 1,409 1,430
9999VB7C 1, 2, 3 & 4 495 575 914 907 899 1136 1,058 1,051 1,043 1,482 1,513 1,534
9999VD9C 1, 2, 3 & 4 501 601 922 911 899 1189 1,098 1,083 1,067 1,512 1,537 1,552
9999WD9C 1, 2, 3 & 4 489 601 914 891 875 1189 1,098 1,083 1,067 1,512 1,537 1,552

Note:
Unit = Total power required for both panels with single power inputs, data includes compressors and asociated fans.
Unit maximum start amps includes 2 or 3 compressors and all associated fans running plus last compressor starting.

Power Factor Information - All Units

YAEP Supply
Model 380 V 400 V 415 V
06RA7C 0.83 0.79 0.76
08TA7C 0.83 0.80 0.75
09TC9C 0.84 0.79 0.78
75UC9C, 7575UC9C 0.84 0.80 0.77
07RA7C, 77UC9C 0.84 0.80 0.77
77WC9C 0.85 0.82 0.79
97VB7C, 997YH7C, 9797VB7C 0.84 0.80 0.78
99VB7C, 9999VB7C 0.85 0.81 0.79
99VD9C, 999YK9C, 9999VD9C 0.84 0.79 0.78
99WD9C, 9999WD9C 0.84 0.81 0.78

25
Physical data - YAEP R407C Units

Table 5b
1 Circuit 2 Circuit
YAEP
06RA7C 07RA7C 08TC7B 09TC9B 55UC9B 75UC9B 77UF7B 77WF7B 97VD7B 99VD7B 99WD9B
Nom. Capacity @ 7C/35C kW 206 242 300 356 389 428 511 543 641 709 748
Unit No. of Capacity Steps (Std.) 2 2 3 3 4 4 4 4 5 6 6
No. of Capacity Steps (Opt.) 3 3 4 4 5 6 6 7 8 8
Number of Compressors 1 1 1 1 2 2 2 2 2 2 2
Comp. Cylinders per Compressor 6 6 8 8 4 6/4 6 6 8/6 8 8
Oil Capacity per Comp. l 11 11 11 11 11 11 11 11 11 11 11
NumberofCoolers 1 1 1 1 1 1 1 1 1 1 1
Cooler RefrigerantCircuits(each) 1 1 1 1 2 2 2 2 2 2 2
Water Capacity (each) l 61 61 90 90 135 135 135 205 150 150 205
Face Area m2 11.9 11.9 11.9 11.9 11.9 11.9 17.8 17.8 23.8 23.8 23.8
Cond. Quantity 4 4 4 4 4 4 6 6 8 8 8
and
Fans Power (each) kW 2.2 2.2 2.2 3.8 3.8 3.8 2.2 2.2 2.2 2.2 3.8
3
Total Airflow m /s 30 30 30 35 35 35 46 45 61 61 70
Refrigerant Charge Systems 1 kg 56 56 58 60 30 32 37 45 51 51 57
Refrigerant Charge Systems 2 kg 30 32 37 45 51 51 57
Refrigerant Charge Systems 3 kg
Refrigerant Charge Systems 4 kg
Ship (Main) kg 2314 2314 2881 3132 3785 3875 4426 4887 5071 5204 5895
Alumini
Weight Ship (Aux.) kg
um Fins
Operating kg 2375 2375 2971 3222 3920 4010 4561 5088 5221 5354 6100
Length mm 2969 2969 2969 2969 2969 2969 4193 4193 5703 5703 5703
Dims. Width mm 2241 2241 2241 2241 2241 2241 2241 2241 2241 2241 2241
Height mm 2490 2490 2490 2490 2490 2490 2490 2490 2490 2490 2490
Sound Power Level dBA 100 100 100 102 102 104 103 103 104 104 106

26
Physical data - YAEP R407C Units

3 Circuit 4 Circuit
YAEP
777YG7B 997YJ7B 999YK9B 7575UC9B 9797VD7B 9999VD7B 9999WD9B
Nom. Capacity @ 7C/35C kW 829 1016 1121 855 1281 1418 1495
Unit No. of Capacity Steps (Std.) 6 8 9 8 10 12 12
No. of Capacity Steps (Opt.) 9 11 12 10 14 16 16
Number of Compressors 3 3 3 4 4 4 4
Comp. Cylinders per Compressor 6 8/8/6 8 6/4 8/6 8 8
Oil Capacity per Comp. l 11 11 11 11 11 11 11
NumberofCoolers 1 1 1 2 2 2 2
Cooler RefrigerantCircuits(each) 3 3 3 2 2 2 2
Water Capacity (each) l 524 524 524 135 150 150 205
Face Area m2 29.7 35.7 35.7 23.8 47.6 47.6 47.6
Cond. Quantity 10 12 12 8 16 16 16
and
Fans Power (each) kW 2.2 2.2 3.8 3.8 2.2 2.2 3.8
3
Total Airflow m /s 75 90 105 70 122 122 139
Refrigerant Charge Systems 1 kg 51 63 63 30 51 51 57
Refrigerant Charge Systems 2 kg 51 63 63 30 51 51 57
Refrigerant Charge Systems 3 kg 51 61 67 30 51 51 57
Refrigerant Charge Systems 4 kg 30 51 51 57
Ship (Main) kg 7105 8474 9323 3875 5071 5204 5895
Alumini
Weight Ship (Aux.) kg 3875 5071 5204 5895
um Fins
Operating kg 7629 8998 9865 8020 10442 10708 12200
Length mm 7682 8901 8901 6128 11705 11705 11705
Dims. Width mm 2241 2241 2241 2241 2241 2241 2241
Height mm 2490 2490 2490 2490 2490 2490 2490
Sound Power Level dBA 106 107 107 107 107 107 109

27
Electrical Data - YAEP R407C Units

Table 6b
Single Point Input (to each panal) - Connection to Disconnect Switcth (Std.) or Terminal Block (Opt.)
YAEP Supply for Panel KW Panel Nominal Amps Panel Maximum Amps Panel Max Start Amps
Model Panel(s) Nom. Max. 380 V 400 V 415 V 342 V 380 V 400 V 415 V 380 V 400 V 415 V
06RA7B Main 71 91 131 131 130 184 156 155 154 458 482 508
07RA7B Main 87 115 167 167 166 219 214 212 209 549 578 600
08TC7B Main 97 121 188 188 187 238 224 224 223 689 725 752
09TC9B Main 123 150 227 225 222 302 274 271 265 689 725 752
55UC9B Main 137 163 248 245 241 333 298 293 285 506 522 532
75UC9B, 7575UC9B Main & Auxiliary 151 188 271 268 265 362 339 331 326 681 706 727
77UF7B Main 167 225 323 321 319 426 417 411 405 757 784 803
77WF7B Main 179 225 331 329 327 426 417 411 405 757 784 803
97VD7B, 9797VD7B Main & Auxiliary 197 250 365 364 362 508 454 448 443 879 912 936
99VD7B, 9999VD7B Main & Auxiliary 242 288 449 448 446 578 529 522 518 953 986 1011
99WD9B, 9999WD9B Main & Auxiliary 252 300 465 460 454 604 549 538 530 963 994 1017
Main 177 225 331 329 327 426 417 411 405 757 784 803
777YG7B
Auxiliary 87 115 167 167 166 219 214 212 209 549 578 600
Main 244 288 449 448 448 578 529 522 518 953 986 1011
997YJ7B
Auxiliary 85 115 167 167 166 219 214 212 209 549 578 600
Main 252 300 465 460 454 604 549 538 530 963 994 1017
999YK9B
Auxiliary 126 150 232 230 227 302 274 269 265 689 752 752
Note:
Panel =Power required for each panel with a single power input, data includes compressors and asociated fans.
One and two circuit units have a one panel, three and four circuit units have two panels each requiring a separate power supply.
System = Each Independent (system) refrigerant circuit. System 1 or 1 & 2 = Main Panel. System 3 or 3 & 4 = Auxillary Panel.
Panel maximum start amps includes 1 compressor and all associated fans running plus second compressor starting.

Multi Point Input - Connection to Fuse Block (Opt.) or Terminal Block (Opt.)
YAEP Supply for System KW System Nominal Amps System Maximum Amps Part Wind Inrush
Model System(s) Nom. Max. 380 V 400 V 415 V 342 V 380 V 400 V 415 V 380 V 400 V 415 V
06RA7B 1 71 91 131 131 130 184 156 155 154 458 482 508
07RA7B 1 87 115 167 167 166 219 214 212 209 549 578 600
08TC7B 1 97 121 188 188 187 238 224 224 223 689 725 752
09TC9B 1 123 150 227 225 222 302 274 271 265 689 725 752
55UC9B 1&2 69 82 124 122 120 167 149 146 142 357 376 390
1, & 3 91 114 164 162 160 214 207 203 199 549 578 600
75UC9B, 7575UC9B
2, & 4 60 74 107 106 105 148 132 128 127 356 376 390
77WF7B 1&2 90 113 165 165 164 213 208 206 203 549 578 600
77UF7B 1&2 84 113 161 161 160 213 208 206 203 549 578 600
1, & 3 121 144 224 224 223 289 264 261 259 689 725 752
97VD7B, 9797VD7B
2, & 4 76 106 141 140 139 219 190 187 184 549 578 600
99VD7B, 9999VD7B 1 & 2, 3 & 4 121 144 224 224 223 289 264 261 259 689 725 752
99WD9B, 9999WD9B 1 & 2, 3 & 4 126 150 232 230 227 302 274 269 265 689 725 752
1&2 89 113 165 165 164 213 208 206 203 549 578 600
777YG7B
3 87 115 167 167 166 219 214 212 209 549 578 600
1&2 122 144 224 224 224 289 264 261 259 689 725 752
997YJ7B
3 85 115 167 167 166 219 214 212 209 549 578 600
1&2 126 150 232 230 227 302 274 269 265 689 725 752
999YK9B
3 126 150 232 230 227 302 274 269 265 689 752 752
Note:
System = Power required for each individual system (refrigerant circuit including compressor and asociated fans)
Data models 75UC9B, 997YJ7B, 7575UC9B, 97VD7B, 9797VD7B, 777YG7B, 997YJ7B, 999YK9B given in two rows, with largest system first. Part wind inrush is the compressor starting.

28
Electrical Data - YAEP R407C Units

Total Unit Data 3 & 4 Circuit Models only Refer to Single Point Input for 1 and 2 Circuit Unit Data

YAEP Total Supply for Unit KW Unit Nominal Amps Unit Maximum Amps Unit Max Start Amps
Model systems Nom. Max. 380 V 400 V 415 V 342 V 380 V 400 V 415 V 380 V 400 V 415 V
777YG7B 1, 2 & 3 264 340 498 496 493 645 631 623 614 972 995 1011
997YJ7B 1, 2 & 3 328 402 616 614 613 797 743 733 726 1168 1198 1220
999YK9B 1, 2 & 3 379 451 697 689 680 907 823 806 794 1238 1263 1282
7575UC9B 1, 2, 3 & 4 301 375 542 537 531 723 678 663 653 1020 1037 1053
9797VD7B 1, 2, 3 & 4 394 500 731 728 724 1016 909 896 886 1333 1360 1379
9999VD7B 1, 2, 3 & 4 483 575 898 895 891 1156 1058 1043 1035 1482 1507 1528
9999WD9B 1, 2, 3 & 4 505 601 930 919 907 1208 1098 1075 1059 1512 1531 1546

Note:
Unit = Total power required for both panels with single power inputs, data includes compressors and asociated fans.
Unit maximum start amps includes 2 or 3 compressors and all associated fans running plus last compressor starting.

Power Factor Information - All Units

YAEP Supply
Model 380 V 400 V 415 V
08TC7B 0.83 0.80 0.75
09TC9B 0.83 0.79 0.75
55UC9B 0.84 0.82 0.80
06RA7B 0.83 0.79 0.76
75UC9B, 7575UC9B 0.84 0.81 0.79
07RA7B, 77UF7B, 777YG7B 0.85 0.82 0.79
77WF7B 0.84 0.81 0.78
97VD7B, 997YJ7B, 9797VD7B 0.82 0.80 0.78
99VD7B, 999YK9B, 9999VD7B 0.80 0.79 0.78
99WD9B, 9999WD9B 0.80 0.79 0.78

29
Power Supply Connections
(Main Panel on 1 Circuit Units and Auxiliary Panel on 3 Circuit Units)

YAEP 06R-09T (Main Panel), Common Input Section Power Section


777Y, 997Y, 999Y (Auxiliary Panel Only) Control Circuit Switch
Disconnect / Emergency
Stop Device

Control
Section

Power
Section 1

Common
Input
Section

Protective
Earth
Standard Single Point Power Supply
One supply to master non-fused disconnect switch (QCSISD) Non-Fused
with internal power distribution to control supply to non- Disconnect Switch
fused disconnect switch (QCSD/ESD) derived internally.

1 PS System Fuses,
or Terminal Block Protective
CIS Earth
F F F
QCSISD
U V W

PE 3 4
Multi Point Power Supply Options
One supply to fuse/terminal block with separate control
supply to non-fused disconnect switch. (QCSD/ESD)
APB

1 PS
AMB ARB
PE
L1 L2 L3 QRESB
CS
3 50 Hz 380/400 V Fuses
CIS or Terminal
3
4 Blocks
Designation Description F F F

QCSD/ESD PE
AMB Microprocessior Board PE

APB Power Supply Board


ARB Relay Board
CS Control Section
CIS Common Input Section
F Fuse
PE Protective Earth
QRESB
PS Power Section
QCSD/ESD Control Circuit Switch Disconnect/Emergency Stop Device
PE PE
QCSISD Common Supply Input Switch Disconnect L1 L3 L1 L2 L3
2 50Hz 3 50Hz
QCSITB Common Supply Input Terminal Block 380/400V 380/400V
QRESB Remote Emergency Stop Button

30
Power Supply Connections
(Main Panel on 2, 3 and 4 Circuit Units and Auxiliary Panel on 4 Circuit Units)

YAEP 55U-77W (Main Panel Only) Common Input Section Power Section
7575U (Main & Auxiliary Panels)
Control Circuit Switch
Disconnect / Emergency
Control Stop Device
Section
Power Power
Section 1 Section 2
Common
Input
Section

YAEP 97V-99W (Main Panel Only)


777Y, 997Y, 999Y (Main Panel Only) System Fuses,
9797V, 9999W (Main & Auxiliary Panels) or Terminal
Block

Protective
Control
Non-Fused Protective Earth
Section Disconnect Switch Earth
Power Power
Section 1 Section 2
Common
Input
Section Designation Description
AMB Microprocessior Board
APB Power Supply Board
ARB Relay Board
CS Control Section
Standard Single Point Power Supply CIS Common Inpuut Section
F Fuse
1 PS 2 PS
CIS PE Protective Earth
F F F F F F PS Power Section
QCSISD
U V W
QCSD/ESD Control Circuit Switch Disconnect/Emergency Stop Device
PE 3 4 QCSISD Common Supply Input Switch Disconnect
QCSITB Common Supply Input Terminal Block
One supply per panel QRESB Remote Emergency Stop Button
to master non-fused
disconnect switch (QCSISD)
with internal power
distribution to fuses,
Multi Point Power Supply Options
L1 L2 L3
PE
QRESB
control supply to non-fused
APB

3 50 Hz 380/400 V disconnect switch (QCSD/ 1 PS 2 PS


ESD) derived internally. AMB ARB

CS
Fuse Block Fuse Block
Single Point Power Supply Option Terminal CIS or Terminal
3
Block 4 Block
F F F F F F
1 PS 2 PS QCSD/ESD PE
CIS PE PE
F F F F F F
QCSITB
U V W

PE 3 4
Two supplies per
One supply per panel to panel to circuit
a common terminal block fuse/terminal block
(QCSITB) with internal with separate QRESB
power distribution to fuses, control supply
control supply to non-fused to non-fused
PE
L1 L2 L3
PE
QRESB
disconnect switch (QCSD/ disconnect switch
PE
L1 L2 L3 L1 L3 PE
L1 L2 L3
2 50Hz
3 50 Hz 380/400 V ESD) derived internally. (QCSD/ESD).
3 50Hz
380/400V
3 50Hz
380/400V 380/400V

31
Control Connections
(Main Panel on 1, 2, 3 & 4 Circuit Units and Auxiliary Panel on 3 & 4 Circuit Units)

YAEP 06R-09T (Main Panel) YAEP 55U-77W (Main Panel Only) YAEP 97V, 99W (Main Panel Only)
777Y, 997Y, 999Y (Auxiliary Panels Only) 7575U (Main & Auxiliary Panels) 777Y, 997Y, 999Y (Main Panel Only)
9797V-9999W (Main & Auxiliary Panels)

Control Control Control


Section Section Section
Power Power Power Power Power
Section 1 Section 1 Section 2 Section 1 Section 2
Common Common Common
Input Input Input
Section Section Section

Control Section

Designation Description
AMB Microprocessior Board
APB Power Supply Board
ARB Relay Board
CS Control Section
Communications Link Cable
to be field run and CIS Common Inpuut Section
connected to Main Panel PS Power Section
TB7 during Installation

Chilled Liquid Flow Switch

Note 1: Fit link bettween terminals 14 and 15 and connect a voltage free contact to terminals 11 and 14
for combined Remote Start/Stop of systems 1/2 (2 circuit units) and systems 3/4 (4 circuit units)

32
Dimensions

06RA7C, 07RA7C, 08TA7C, 09TC9C, 06RA7B, 07RA7B, 08TC7B, 09TC9B

for cable entry


extention box
Optional
520

446
System 1

2 1 7 2 AVM CL
Control
Panel

2 2 41
1 48
840
1990
Inlet

1 9 1 1 AVM CL

2 89 7
B
2969

Outlet

A
49 3 AVM

2490
9 46

Model A B C Cooler Connections


06RA7C, 06RA7B, 07RA7C, 07RA7B 450 1880 310 4" (100 mm)
08TA7C, 08TC7B, 09TC9C, 09TC9B 500 1778 335 6" (150 mm)

33
34
Model

77WC9C
Dimensions

75UC9C, 77UC9C, 55UC9B, 75UC9B


A
2160
2108
2969
75UC9C, 77UC9C, 77WC9C, 55UC9B, 75UC9B

B
Control

423
449
Outlet Inlet Panel
System 1 System 2
Optional
supply cable

2490
spreader box
Compressor
Compressor
System 2
System 1
C

C
382
446
2 2 41 49 3 1 9 1 1 AVM CL 7 02
A B 2 1 7 2 AVM CL

2 89 7

6" (150 mm)


8" (200 mm)
Cooler Connections
Model
77UF7B
77WF7B
77UF7B, 77WF7B
Dimensions

1631
1605
4250

2241

B
2160
2108
Control
Panel
Outlet Inlet System 1 System 2

2490

C
382
446
C

312 1676 AVM CL 1707 AVM CL 493 Compressor Extension Box Compressor
System 1 option for use with System 2
A B common supply
702
4187
2166 AVM C
L

6" (150 mm)


8" (200 mm)
Cooler Connections

35
36
Dimensions

1800
5700

Model
221

99WD9C, 99WD9B
97VB7C, 99VB7C, 99VD9C, 97VD7B, 99VD7B
8" (200 mm) 8" (200 mm)
1153

Outlet Inlet

2490
124

446
407
838

C
97VB7C, 99VB7C, 99VD9C, 99WD9C, 97VD7B, 99VD7B, 99WD9B

634 2108 702


2166 AVM C
L Compressor
System 2
199 AVM 2438 AVM CL 1220 AVM C
L 1257 AVM CL 292 AVM
2241
5407 System 1 Compressor
removed for drawing clarity
777YG7B

221
Main
Panel
Dimensions

1800
7682 Compressor Compressor
System 1 System 2

Main Unit Auxiliary Unit 2241

Inlet Outlet Aux.


10" (250 mm) 10" (250 mm) Panel

1153

2490
837
496

3048 Compressor
2057
System 3
386 1278 1221 1730 1148 1210
2170
AVM CL AVM CL AVM CL AVM CL AVM CL AVM CL AVM CL
7359

37
38
221
Main
Panel
Dimensions

1800
8901 Compressor Compressor
997YH7C, 999YK9C, 997YJ7B, 999YK9B

System 1 System 2

Main Unit Auxiliary Unit 2241

Inlet Outlet Aux.


10" (250 mm) 10" (250 mm) Panel

1153
2490
838
496

3070 2057
Compressor
1263 System 3
402 1220 2527 1572 1191
AVM CL AVM CL AVM CL AVM CL AVM CL AVM CL
8578 2170
AVM CL
Dimensions

7575UC9C, 7575UC9B

6232

2241
Auxiliary Unit Main Unit

Inlet Outlet Outlet Inlet


6" (150 mm) 6" (150 mm) 6" (150 mm) 6" (150 mm) System 1 System 2
1150

2490
840

382

Compressor Extension Box Compressor


1911 AVM CL 493 493 1911 AVM C
L System 1 option for use with System 2
common supply
423 2160 2160 423

2172 AVM C
L
2897 2897
300

39
40
Multi Point Single Point Single Point Multi Point
Cable entry Cable entry Cable entry Cable entry
System 3 System 3 & 4 System 1 & 2 System 2
Dimensions

1800
Multi Point Cable entry System 4 Multi Point Cable entry System 1

221
11700

Compressors 8" (200 mm) 8" (200 mm) Compressors


System 3, 4 Inlet Outlet System 1, 2

1153

2490
Compressors
838

System 2, 3

446
702
292 1257 AVM 1220 AVM 2438 AVM Postions 699 1257 AVM 292 2166 AVM Postions

2241
292 2664 2108 1568 2664 292
System 1 & 4 Compressors
5407 5407 removed for drawing clarity

Distance between
300
cooler outlets Dimensions and AVM positons are
9797VB7C, 9999VB7C, 9999VD9C, 9999WD9C, 9797VD7B, 9999VD7B, 9999WD9B

Distance to cooler Inlet identical for both sections-refer to


Cooler Inlet to Outlet 2108 mm other section for details
Weight Distribution, AVM Data

YAEP R22 Units with Aluminium Fins


Aluminium Fins 06RA7C 07RA7C 08TA7C 09TC9C 75UC9C 77UC9C 77WC9C
F1 kg 565 565 544 670 929 949 1072
AVM Colour OR OR GN GY WH WH GD
F2 kg 658 658 1041 1041 1076 1098 1263
AVM Colour GN GN WH WH GD GD GD
F3 kg 618 618 679 814 1076 1098 1263
AVM Colour GN GN GY GY GD GD GD
F4 kg 533 533 707 698 929 949 1072
AVM Colour OR OR GY GY WH WH GD
Total kg 2375 2375 2971 3222 4010 4093 4670

Aluminium Fins 97VB7C 99VB7C 99VD9C 99WD9C 997YH7C 999YK9C 7575UC9C 9797VB7C 9999VB7C 9999VD9C 9999WD9C
F1 kg 476 454 513 599 763 823 929 476 454 513 599
AVM Colour OR GN GN GY GY GY WH OR GN GN GY
F2 kg 599 721 781 846 513 818 1076 599 721 781 846
AVM Colour GN GY GY WH GN GY GD GN GY GY WH
F3 kg 603 735 786 818 519 538 1076 603 735 786 818
AVM Colour GN GY GY GY GN GN GD GN GY GY GY
F4 kg 911 753 786 786 525 525 929 911 753 786 786
AVM Colour WH GY GY GY GN GN WH WH GY GY GY
F5 kg 658 753 786 786 1047 1029 929 658 753 786 786
AVM Colour GN GY GY GY WH WH WH GN GY GY GY
F6 kg 658 735 786 818 1053 1241 1076 658 735 786 818
AVM Colour GN GY GY GY WH GD GD GN GY GY GY
F7 kg 655 721 781 846 1053 1241 1076 655 721 781 846
AVM Colour GN GY GY WH WH GD GD GN GY GY WH
F8 kg 518 454 513 599 1047 1029 929 518 454 513 599
AVM Colour OR GN GN GY WH WH WH OR GN GN GY
F9 kg 525 525 518 454 513 599
AVM Colour GN GN OR GN GN GY
F10 kg 519 538 655 721 781 846
AVM Colour GN GN GN GY GY WH
F11 kg 513 818 658 735 786 818
AVM Colour GN GY GN GY GY GY
F12 kg 763 823 658 753 786 786
AVM Colour GY GY GR GY GY GY
F13 kg 911 753 786 786
AVM Colour WH GY GY GY
F14 kg 603 735 786 818
AVM Colour GN GY GY GY
F15 kg 599 721 781 846
AVM Colour GN GY GY WH
F16 kg 476 454 513 599
AVM Colour OR GN GN GY
Total kg 5079 5326 5732 6100 8841 9948 7028 10157 10652 11463 12200

Refer to AVM location diagram for AVM positions.

41
Weight Distribution, AVM Data

YAEP R407 Units with Aluminium Fins


Aluminium Fins 06RA7B 07RA7B 08TC7B 09TC9B 55UC9B 75UC9B
F1 kg 565 565 544 670 907 929
AVM Colour OR OR GN GY WH WH
F2 kg 658 658 1041 1041 1053 1076
AVM Colour OR OR WH WH WH GD
F3 kg 618 618 679 814 1053 1076
AVM Colour OR OR GY GY WH GD
F4 kg 533 533 707 698 907 929
AVM Colour OR OR GY GY WH WH
Total kg 2375 2375 2971 3222 3920 4010

Aluminium Fins 77UF7B 77WF7B 97VD7B 99VD7B 99WD9B 777YG7B 997YJ7B 999YK9B 7575UC9B 9797VD7B 9999VD7B 9999WD9B
F1 kg 383 519 496 464 599 508 758 814 929 496 464 599
AVM Colour GN GN OR GN GY OR GY GY WH OR GN GY
F2 kg 887 777 618 725 846 624 513 809 1076 618 725 846
AVM Colour WH GY GN GY WH GN GN GY GD GN GY WH
F3 kg 1010 1248 618 739 818 615 522 531 1076 618 739 818
AVM Colour WH GD GN GY GY GN GN GN GD GN GY GY
F4 kg 1010 1248 925 749 786 603 538 522 929 925 749 786
AVM Colour WH GD WH GY GY GN GN GN WH WH GY GY
F5 kg 887 777 674 749 786 590 1078 1023 929 674 749 786
AVM Colour WH GY GN GY GY GN WH WH WH GN GY GY
F6 kg 383 519 674 739 818 874 1090 1233 1076 674 739 818
AVM Colour GN GN GN GY GY GY WH GD GD GN GY GY
F7 kg 674 725 846 874 1090 1233 1076 674 725 846
AVM Colour GN GY WH GY WH GD GD GN GY WH
F8 kg 543 464 599 590 1078 1023 929 543 464 599
AVM Colour OR GN GY GN WH WH WH OR GN GY
F9 kg 603 538 522 543 464 599
AVM Colour GN GN GN OR GN GY
F10 kg 615 522 531 674 725 846
AVM Colour GN GN GN GN GY WH
F11 kg 624 513 809 674 739 818
AVM Colour GN GN GY GN GY GY
F12 kg 508 758 814 674 749 786
AVM Colour OR GY GY GN GY GY
F13 kg 925 749 786
AVM Colour WH GY GY
F14 kg 618 739 818
AVM Colour GN GY GY
F15 kg 618 725 846
AVM Colour GN GY WH
F16 kg 496 464 599
AVM Colour OR GN GY
Total kg 4561 5088 5221 5354 6100 7629 8998 9865 8020 10443 10708 12200

Refer to AVM location diagram for AVM positions.

42
AVM Locations - All Models

4 3

CONTROL PANEL
06RA7C, 07RA7C, 08TA7C,
09TC9C, 75UC9C, 77UC9C,
77WC9C, 06RA7B, 07RA7B,
08TC7B, 09TC9B, 55UC9B,
75UC9B
1 2

6 5 4
CONTROL PANEL

77UF7B, 77WF7B

1 2 3

8 7 6 5
CONTROL PANEL

97VB7C, 99VB7C, 99VD9C, 99WD9C,


97VD7B, 99VD7B, 99WD9B

1 2 3 4

12 11 10 9 8 7
MAIN CONTROL PANEL
AUX CONTROL PANEL

997YH7C, 999YK9C,
997YJ7B, 999YK9B

1 2 3 4 5 6

6 5 4 3
MAIN CONTROL PANEL
AUX CONTROL PANEL

7575UC9C, 7575UC9B

7 8 1 2

12 11 10 9 8 7 6 5
AUX CONTROL PANEL

CONTROL PANEL

9797VB7C, 9999VB7C, 9999VD9C, 9999WD9C,


9797VD7B, 9999VD7B, 9999WD9B

13 14 15 16 1 2 3 4

43
Johnson Controls is the global leader that creates
smart environments bringing ingenuity to the
places where people live, work and travel.
Johnson Controls Building Efficiency business enables safe, comfortable,
energy efficient and sustainable facilities.
We are a single source of integrated heating/cooling, controls, lighting, fire, security and wireless
infrastructure products for buildings and industrial plants. And our comprehensive life-cycle
approach to in-building technology and operations includes planning and design, installation
and integration optimization and maintenance as well as integrated real estate and facility
management services.

To us, sustainability matters at every level. Our triple bottom line - Economic Prosperity,
Environmental Stewardship and Social Responsibility - and every facet of our operations and
community involvement are geared to the efficient use of resources to benefit the planet and
people all over the world.

For example, in conjunction with the US Energy Association, Johnson Controls helped to launch
the Annual Energy Efficiency Forum. We are also a lead technology and energy-efficiency
partner for the Clinton Climate Initiative and its ambitious C40 Large Buildings Retrofit Program.
And, building on our unparalleled expertise in LEED (Leadership in Energy Environment Design)
rating and certification, Johnson Controls is supporting a growing number of green building
projects across Asia.

Today Johnson Controls solutions are playing a key role in the regions LEED-certified buildings,
including Indias ITC Green Centre and Nokias Greater China headquarters complex in Beijing.
They can also be found in some of the worlds tallest buildings - Taipei 101, Shanghai World
Finance Center and Petronas Towers, Kuala Lumpur.

Our network of more than 150 sales and support centers with more than 10,000 dedicated
professionals located in 15 countries and regions has made us the partner of choice for some of
the most recognizable structures in Asia and the Pacific, including many of the iconic stadiums
used in the 2008 Beijing Olympics.

Asia Headquarters
20/F, Tower 1, 2 & 3, Enterprise Square 1,
9 Sheung Yuet Road, Kowloon Bay, Kowloon,
Hong Kong
Tel : +852 2590 0012
Fax: +852 2516 5648

Australia China (Shanghai) Hong Kong India


Tel : +61 (2) 9805 8300 Tel : +86 (21) 6276 6509 Tel : +852 2590 0012 Tel : +91 (22) 3082 0391
Fax: +61 (2) 9247 7750 Fax: +86 (21) 6277 3543 Fax: +852 2516 5648 Fax: +91 (22) 3088 1592

Indonesia Japan Korea Macau


Tel : +62 (21) 626 3535 Tel : +81 (3) 5738 6100 Tel : +82 (2) 554 5935 Tel : +853 2875 1820
Fax: +62 (21) 659 8875 Fax: +81 (3) 5738 6298 Fax: +82 (2) 554 5739 Fax: +853 2875 1821

Malaysia New Zealand Philippines Singapore


Tel : +60 (3) 7628 4300 Tel : +64 (9) 444 6434 Tel : +63 (2) 706 1420-22 Tel : +65 6748 0202
Fax: +60 (3) 7874 1180 Fax: +64 (9) 444 2092 Fax: +63 (2) 706 1486 Fax: +65 6284 3473

Taiwan Thailand Vietnam


Tel : +886 (2) 2657 5568 Tel : +66 (2) 717 0751 Tel : +84 (8) 526 1205
Fax: +886 (2) 2657 6388 Fax: +66 (2) 717 0750 Fax: +84 (8) 526 1206

Asia Factories: Guangzhou & Wuxi, China Pune, India


Asia Engineering Centre: Wuxi, China
Asia Centre of Excellence in Engineering (CoEE): Beijing, China Mumbai & Pune, India
Asia Centre of Engineering & Tech nology (CET): Hong Kong
Asia Parts & Product Hub: Shanghai, China
China Refrigeration, Project Engineering Center: Shanghai, China

2009 Johnson Controls, Inc. www.johnsoncontrols.com PUBL-5156 (0309)

Printed on recycled paper