The P2/P3-145 pump has been number is not included in the pump P2-145-0212-01N or P2-145-0212-
upgraded for improved reliability. ordering code, there are no order code 01V -15 design servo cover and volume
The servo cover to housing interface, changes for the complete pump. stop parts will not be able to be used on
link piston to servo piston interface, a -13 design pump. Once -13 design
and the P3 impeller retention method Current orders are being shipped in stock is depleted, these parts will no
have been modified to increase the the -15 design. The design number is longer be available.
life of our pumps. Since the design identified on the nameplate. There are
no pricing changes associated with Link Piston to Servo Piston
Rear View this design upgrade. Engagement
The link piston to servo piston
Servo Cover to Housing Interface engagement has been changed
Servo The servo cover is the part of the from a coarse thread to a fine thread
Cover
pump where the displacement engagement. The fine thread has more
adjustment is located (See Figure 1). threads per inch giving it a larger
The O-ring groove was relocated holding force. To service, both the
to the servo cover from its current servo piston and link piston need to
location on the housing (See Figure 2). be of the same design. Service kits are
This sealing design is more robust available with both parts included.
Ripple
Chamber than the current design.
Plug
DO NOT
Model code example: P2145R00C1C32
REMOVE Service Information TC 20N70S1A1U Note that when
-15 design servo cover and volume servicing the link piston or servo
Rotation
Arrow
screw will only be available in a max piston of a P2/P3-145 pump that has a
volume kit. torque control, the user needs to know
4 TORQUE 5 Nm
5 (44 in-lbf)
Figure 2
4 1
2
4
3
7
6 5
TORQUE 5 Nm