You are on page 1of 8

GE Energy

Digital Energy

MDS WiYZ
TM

Intelligent Data Acquisition

Data Acquisition | MDS Mesh, WiFi, Cellular Versatile


GE's MDS WiYZ is an intelligent data acquisition and networking platform combining wireless connectivity Battery or line powered Remotes
for sensors, I/O, instruments and meters with comprehensive network infrastructure solutions for IP/
Single, sensor or multiple analog & digital I/O
Ethernet and serial, machine-to-machine and backhaul communication to host systems and devices.
I/O Extension to regenerate remote signals
Whether your application requires the collection of data from remote, unpowered sensors or deployment
in areas with obstructed communication paths or a bridge for data using the cellular infrastructure to Poll data using Modbus
your enterprise network, MDS WiYZ products provide versatile, reliable and cost-effective solutions. Collect, time-stamp and store data
FTP for transfer data files
Key Benefits Configurable data sampling & transmission rates
Cost effective wireless communication for sensors, instruments and I/O monitoring remote Bridge communication to RTUs, Meters and
assets Controllers
Improved communication reliability and simplified deployment using standards based, self Bridge between wired & multiple WiFi, MDS and
creating, self healing mesh networking cellular wireless options
Reduce wiring, power and integration costs using battery powered, field hardened
components
Automate data collection using any combination of Cellular, WiFi and MDS backhaul options
Reliable
for seamless IP/Ethernet and serial communication to remote devices Rugged NEMA 4X, IP 65 housings
Global unlicensed use in 2.4 GHz spectrum plus GSM and CDMA cellular technology -40 to 70 C temperature ranges
Class 1, Division 2 rated environments
Application Specific Wireless Solution
Self-healing mesh networking
Oil & Gas
Monitor gas well head tubing and casing pressure
Cost Effective
Collect compressor inlet and discharge pressure values
Battery powered Remotes reduce cost

Heavy Industrial Ultra-low power operation reduces solar power


infrastructure cost
Track remote liquid storage inventories and monitor remote assets
Outdoor, hardened components eliminate extra
Monitor holding pond levels and discharge flow for regulatory reporting
enclosure, accessory and integration costs
Self-creating mesh networking reduces path
Water & Wastewater
analysis and deployment costs
Battery powered remotes monitor storage tank levels Multiple sensor and I/O capacity
Collect pollution discharge flow rates for regulatory compliance

Energy Secure
Monitor pole top circuit breakers and report status 128-bit encryption and authentication
Collect inventory data from gas storage facilities Password protected access and lockdown

g
Frequency hopping 2.4 GHz mesh network

imagination at work
MDS WiYZ

Versatile Data Acquisition Connect Sensors and I/O - Battery or Line


Process optimization, quality control, regulatory compliance, improved Powered
productivity, preventive maintenance, safety and security are just a WiYZ Remotes provide true connection flexibility supporting the direct
few of the requirements that drive the need for data acquisition and connection of a single sensor, or multiple I/O signals from external
monitoring solutions. devices. WiYZs battery power option allows you to install it even when
local power is unavailable and lasts up to 5 years depending upon
Delivering remotely collected data cost effectively to local devices
the number and type of devices connected as well as the required
and systems or to Enterprise networks on a regional, national,
sampling rate. WiYZ constantly monitors and reports battery power
even international scale requires new solutions that bridge multiple
levels so depletion is predictable.
communication methods and technologies. MDS WiYZ products
deliver these solutions for both data acquisition and networking.
Enterprise, System and Device Connectivity
The MDS WiYZ platform contains two components. Field hardened The WiYZ Gateway provides unparalleled performance and versatility.
WiYZ Remotes that implement standards-based mesh communication Interface to local controllers, systems or networks using IP/Ethernet or
and optionally operate on battery power connect sensors, transducers serial connections. Select additional options for wireless connectivity
and I/O. Outdoor WiYZ Gateways that provide Cellular, WiFi and MDS to far-away Enterprise networks using CDMA or GSM cellular networks,
private wireless options for connectivity to remote host systems and local plant infrastructure using WiFi and long range MDS wireless for
devices plus wired IP/Ethernet and serial connections for local RTUs private SCADA networks. Use Modbus to interface with sensor and I/O
controllers and systems. data collected from WiYZ Remotes or move time stamped data files to
Operations centers via FTP.

WiYZ Application Advantages

Operation Center
lar
Cellu

Ethernet Private Network

Serial MDS entraNET SCADA Master


Local Display RTU/PLC
WiFi
WiYZ Gateway

WiYZ Remote WiYZ Remote 3rd party devices


Connect: Connect: Enable:
- Instruments - Sensors - Instruments
- Devices - Switches - Meters
- Meters - Transducers - Transducers

Sensors and I/O Signals System Communication Gateway Connectivity


Use WiYZ Remotes with level, pressure, Interface data to host systems using Enterprise connectivity using public
flow and temperature sensors to Modbus cellular communication
remotely monitor important parameters Transfer data files to Enterprise systems Connect multiple WiYZ networks to
Connect digital signals for status using FTP or SFTP SCADA systems using MDS point-to-
monitoring and control Bridge IP/Ethernet and serial multipoint wireless
Regenerate signals from sensors and communication to remote controllers and Connect to your plant's WiFi
I/O to RTUs and controllers multi-variable transmitters infrastructure

GEDigitalEnergy.com
MDS WiYZ

MDS WiYZ Remote MDS WiYZ Gateway


MDS WiYZ Remotes are packed with features and functionality to The WiYZ Gateway is a powerful and flexible device facilitating wired
match up with a diverse range of remote monitoring and control and wireless connectivity to host systems and Enterprise networks.
requirements. Each Remote accommodates 2 Analog Inputs, 2 Analog The WiYZ Gateway supports up to 4 wireless connectivity options
Outputs, 2 Digital Inputs and 2 Digital Outputs. One RS232 port is for bridging communication between Mesh, Cellular, WiFi and MDS
used for configuration. A second RS232/RS485 port is available for wireless.
connection to an external device.
The WiYZ Gateway establishes and maintains the ISA100 mesh
Configurable sample periods allow remotes to periodically sample network. It also collects data from WiYZ Remotes. Data can be
sensor and I/O data, and transmit back to the gateway at specified locally stored on the gateway in between transmissions to Enterprise
intervals, conserving battery power and reducing network traffic. networks resulting in significant savings in cellular communication
Condition-based data transmission allows remote to transmit data costs. Alternatively, the gateway supports Modbus for direct polling of
only when there is a change of state for a Digital Input sensor and I/O data in real time.

I/O extension can be implemented to regenerate sensor and I/O The WiYZ Gateway operates as a multi-device hub and bridges IP/
signals between devices Ethernet and serial communication (either wired or wireless) anywhere,
between remotes, controllers and PLCs and host systems.
The WiYZ Remote is housed in a NEMA 4X. IP 65 enclosure for harsh
outdoor environments and includes convenient mechanical and Configurable data transmission periods
electrical connection options. The WiYZ Remote also includes an Storage of time stamped data in between data transmissions
omnidirectional antenna plus options for a remote mounted antenna.
Security implementation including encryption and password access
Surface mount , pole mount and conduit mount options simplify
installation. The WiYZ Remote is Class 1 Division 2 approved for use in
The WiYZ Gateway manages the ISA100 mesh network and
hazardous locations.
implements the local user interface. It has a capacity for up to 50 WiYZ
No power? No problem. The WiYZ Remote can be battery powered so remotes. It also implements the cyber security layer for the entire
users can implement monitoring solutions at important locations that network.
have been impractical before. The ultra low power WiYZ Remote drives
The WiYZ Gateway is housed in a NEMA 4X, IP65 enclosure for
lower cost options for solar power equipment when the application
installation in harsh outdoor environments and general safety or Class
exceeds the capacity of the internal battery pack. The battery pack
1 Division 2 approvals for hazardous locations.
can still be used as emergency backup for both solar and line powered
applications.

Mesh Antenna Rugged outdoor Cellular Antenna


Connectivity housing Connectivity

Enclosed
Wiring
Terminations

Conduit Hub
and Cable Gland
Connections. WiFi Antenna MDS Wireless Antenna
Connectivity Connectivity

Industrially Hardened Data Acquisition

Class 1 Div. 2
for hazardous locations Nema 4X, IP 65 housings 40oC to 70oC

GEDigitalEnergy.com
MDS WiYZ

MDS Mesh Networking In the MDS mesh network, all devices can be peers that allow wireless
communication to be routed automatically to the desired destination
The MDS WiYZ implements the ISA100.11a standard for mesh network
even when a direct line of sight path to the Gateway is unavailable.
communication between Remotes and the Gateway. ISA100.11a is an
The mesh network self-forms upon power up, automatically creating
open mesh network standard developed by the International Society
the wireless network and eliminating the cost and effort associated
of Automation (ISA).
with path planning and analysis. Moreover, the mesh network
Mesh networks provide significant benefits in network design, automatically establishes alternate communication paths to the
deployment and reliability versus traditional point to multipoint Gateway and between remotes re-routing communication around
networks. In conventional multipoint networks each remote device obstructions or device failures. The ISA100.11a standard is extremely
must establish a direct, unobstructed wireless path to the network's robust and deterministic. It was designed specifically for the rigors
Access Point or Master. This requires careful upfront planning, path and demands for process automation as well as to coexist with other
analysis and design. wireless solutions that may be in use. It operates in the unlicensed 2.4
GHz spectrum for global use.

Primary Alternate Primary Alternate

Oil & Gas Application - Wireless I/O Extension


Use the MDS WiYZ I/O Extension feature to regenerate I/O signals at meters, RTUs and controllers when direct wiring is too expensive or impractical.
Gas wellhead pressure values can be monitored by a WiYZ remote located at the wellhead and regenerated by another WiYZ remote into an RTU or
Flow meter.

Analog Inputs
Analog Outputs
EFM/RTU

Use WiYZ to measure pressures at a gas wellhead


Connect pressure instruments or transducers directly to
a WiYZ Remote
Transmit pressure values to a WiYZ remote at RTU or
Flow meter
Regenerate the pressure values as 0-5 V or 0-20 mA
signals to RTU
Connect 1-2 Analog and 1-2 Digital signals per remote
Use WiYZ Remotes internal battery power at locations
without power
Eliminate need to run signal wire between wellhead and
meter site

EFM/RTU
Pressure Inputs Analog Outputs

GEDigitalEnergy.com
MDS WiYZ

Heavy Industrial Application - Remote Data Collection & Networking


Collect process data from remote assets using IP/Ethernet to local PLC or controller for monitoring and control applications where it is cost prohibitive
to run signal wire or when power is unavailable. Use WiYZ to directly connect sensors, transducers or I/O from instruments and meters. WiYZ
Remotes automatically form a mesh network around obstructions to the WiYZ Gateway.

Use WiYZ to automatically create a mesh data acquisition


network for remote assets
Collect level, pressure and status data from remote
devices and send to Gateway
Remote Remote Remote Gateway
Connect PLC or Controller to WiYZ serial or IP/Ethernet
Pressure IP/Ethernet or Serial port
Use Modbus to poll data collected at WiYZ Gateway
Use WiYZ Remote battery power at locations without
power or DC power at both Remote and Gateway
Use WiYZ to power transducers and instruments
Remote Remote
PLC (Control)

Tank Level

Heavy Industrial Application - Cellular or MDS eNET Backhaul


When Operations centers and Enterprise networks need long range access to remote sites, use the Cellular infrastructure or MDS eNET option. The
WiYZ Gateway operates not only as the access point to the MDS Mesh network, but also supports WiFi for local drive-up data access.

Analog Inputs

or
Cellular or
GE MDS eNET
Ethernet
Operation Center SCADA Master

PLC/RTU
Analog Inputs Collect data from WiYZ gateway using Modbus TCP
polling
Analog Inputs
Transfer data that is logged and timestamped in the
Gateway via ftp to host systems.
Use the WiYZ Gateway to create a local IP/Ethernet
network for other metering devices and controllers
WiFi Use GSM/EDGE or CDMA2000 1xRTT to communicate
with remote WiYZ networks
Use WiYZ for drive up WiFi access to remote data and
Ethernet
network

Analog Inputs PLC/RTU

GEDigitalEnergy.com
MDS WiYZ

Utility Application Substation Network Infrastructure


When a utility uses WiFi at a substation to collect data from IEDs or RTUs and monitor status/condition information the WiYZ Gateway can operate
as the WiFi access point to bridge wireless Ethernet and serial data onto the Cellular network or private MDS eNET network. The WiYZ Gateway also
supports wired Ethernet and serial connectivity to interface other devices and systems.

Use the WiYZ Gateway to bridge WiFi enabled IEDs or


Cellular or controllers onto cellular infrastructure or IP/Ethernet hub
GE MDS eNET or
Optionally connect Ethernet and serial devices to the WiYZ
Operation Center SCADA Master Gateway
Use WiYZ Remotes to monitor other substation status
points
Use GE MDS eNET to monitor other devices remote from
the substation

WiFi WiFi

PLC (Control) PLC (Control) PLC (Control)

Heavy Industrial Application Facility Data Acquisition and Networking


When process facilities need to automate data collection from remote assets, metering devices and controllers WiYZ has the versatility not only to
form a mesh network around obstructions and interference but also to provide wireless serial and IP/Ethernet connectivity. The WiYZ Gateway can
operate as a WiFi station for connection to an existing WiFi network or create a MDS eNET network for a comprehensive network infrastructure.

WiFi
Private Network

Remote Remote Gateway MDS or WiFi Gateway Remote


Access Point
Current Tank Level
Remote

Remote Remote PLC (Control)

Pressure SCADA Remote

Collect data from multiple WiYZ Gateways and Remote clusters monitoring status, pressure level and temperature parameters
Provide IP/Ethernet and serial communication to remote controllers
Bridge remote data onto facility WiFi networks
Use GE MDS eNET to for license free communication to plant control and monitoring systems

GEDigitalEnergy.com
MDS WiYZ

MDS WiYZ Device Manager MDS WiYZ Starter Kits


Use the web based WiYZ Device Manager for convenient, intuitive MDS WiYZ Starter Kits simplify ordering for the Gateway and up to 5
configuration and maintenance of WiYZ devices. Device Manager is Remotes. Each contains a Gateway and the necessary antennas and
resident in the WiYZ Gateway and can be accessed via the Ethernet accessories for installation. Kits are available for 2, 3 and 5 remotes.
port or over the air via any of the backhaul options. The WiYZ Device
Manager provides a comprehensive set of tools and utilities such as
configuration wizards, device profiles for repetitive configuration tasks
and utilities for saving device configurations and upgrading firmware.

Access over-the-air or using Gateway Ethernet port


Device profiles simplify repetitive setup tasks x2 x3 x5
Built-In Wizards guide users through multi-step configuration
processes
View I/O Data and Status information from WiYZ Remotes or other
devices on the WiYZ network Comprehensive Network Management
View data logged on Gateway in trend graph formats Manage WiYZ using PulseNETTM NMS. PulseNET is purpose-built for
View device status and performance information industrial communications and includes sophisticated and meaningful
pre-built workflows along with intuitive graphical representations of
Simple Maintenance Menus for firmware upgrade and saving radio
the network at your fingertips.
configuration
Menus for broadcasting firmware upgrades to all Remotes
Network Configuration Features
Setup bridging over multiple wireless option
Monitor network status and health

Power Consumption
WiYZ Gateway Power Consumption
12 VDC Power 24 VDC Power

Rx Tx Rx Tx

Base Gateway 211 mA 212 mA 106 mA 106 mA

Cellular Modem 32 mA 168 mA 16 mA 84 mA

eNET 117 mA 562 mA 58 mA 281 mA

WiFi 138 mA 298 mA 69 mA 149 mA

Sensor Kits and Accessories WiYZ Remote Power Consumption

WiYZ Sensor kits are available for typical monitoring applications 12 VDC Power 24 VDC Power

involving pressure, level and temperature. They are optimized Sleep Rx Tx Sleep Rx Tx
whenever practical to take advantage of
111 A 12 mA 110 mA 55 A 6 mA 53 mA
WiYZ low power battery operation. A full
array of important accessories such as
antennas, lightning protection and cabling
are available for convenient ordering for any
WiYZ installation.

GEDigitalEnergy.com
MDS WiYZ

Specifications
GENERAL CELLULAR OPTIONS I/O SPECIFICATIONS
Gateway Power 10-30 vDC CDMA 1xRTT (Verizon) ANALOG INPUTS
Remote Power 7-30 vDC GSM/GPRS EDGE (AT&T) Types 0-100 mV, 0-22 mA, 0-5 V
Temperature -40C to 70C WIFI OPTION Accuracy .1% of Span
-30C to +60C w/ cellular 802.11b/g Access Point, Station, Ad Hoc A/D Resolution 12 bit
Housing Die-cast Aluminum Carrier Power 0.1 watts (20 dBm) ANALOG OUTPUTS
Area Approval Class 1, Division 2, Groups A, B, 900 MHZ OPTION Types 0-22 mA, 0-5 VDC
C, D for hazardous locations Data Rate 106 kbps Accuracy .1% of Span
WIYZ GATEWAY Frequency 902-928 MHz ISM band Isolation 1400 V output to power
Size 8.0 H x 11.75 W x 3.0 D in. Mode Frequency Hopping D/A resolution 12 bits
20.3 H x 29.8 W x 7.6 D cm.
Range Up to 25 miles DIGITAL INPUTS
Weight 5 Lbs (2.9 kg)
System Gain 136 dB Type 5-36 vDC
Antenna(s) N-female
Carrier Power 0.1 To 1.0 watts (20 to 30 dBm) Isolation 1,500 V to chassis ground
Ethernet Port One RJ45 10/100BaseT
Receiver Sensitivity -106 dBm (1 x 10-6 BER) DIGITAL OUTPUTS
Serial Port Two DB9, RS232, 1.2 to 115.2
2.4 GHZ OPTION Type FET relay
kbps
Data Rate 106 kbps Capacity 36 vDC
LAN Protocols 802.3 (Ethernet),
802.1D(Spanning Tree), TCP/ Frequency 2.4016 2.4778 GHz ISM Load 2A continuous (per output)
IP, DHCP, ICMP, SFTP, FTP, UDP, Mode Frequency Hopping Isolation 1,500 V to chassis ground
SNMP v1,/v2/v3, NTP, HTTPS Channels Selectable 80 to 128 APPROVALS
Security Encryption, Password Access, Range FCC/IC Up to 15 miles FCC Part 15, SubpartC
MAC Address block list Range ETSI Up to 1200 meters / 3900 feet IC Industry RSS-Gen Issue 2/RSS 210 Issue 7
VPN IPSEC, Open VPN System Gain 131 dB Canada
MESH SPECIFICATIONS Carrier Power 0.1 To 0.5 watts (20 to 27 dBm) ETSI /CE
Frequency 2.4 to 2.4835 GHz Carrier Power-ETSI 0.01 to 0.1 watts (10 to 20 dBm) UL General ITE, Class 1 Division 2
Range 1500 ft. Receiver Sensitivity -104 dBm (1 x 10-6 BER) PROTOCOLS
Carrier Power 13 dBm WIYZ REMOTE Modbus TCP
Carrier Power - 0.01 to 0.1 watts I/O Capacity 2 AI, 2 AO, 2 DI, 2 DO Modbus RTU
ETSI (10 to 20 dBm)
Size 5.5 H x 6.0 W x 3.5 D in. FTP/SFTP
Receiver Sensitivity -95 dBm (1 x 10-6 BER) 14 H x 15.2 W x 8.9 D cm.
Weight 3.7 lbs (1.7 kg)
Housing Die-cast Aluminum

Remote Ordering
WiYZR- M * 4 * A * * N * * * * WiYZ Remote Nema 4X, IP 65, MDS Mesh
N General UL Order Code Example
2 Class I Division 2 WiYZR-M24FAF1NNP1FN
F FCC/IC
E ETSI/CE Class 1 Division 2
E 7-30 VDC NEMA 4X Housing
F Internal 14 AH, 10 V Battery Bracket FCC/IC Approval
1 2 AI (0-5 VDC), 2 AO (0-5 VDC), 2 DI, 2 DO ISA100.11a Mesh
2 2 AI (0-100 mV), 2 AO (0-5 VDC), 2 DI, 2 DO Battery Powered
3 2 AI (0-20 mA), 2 DI, 2 DO 0-5 VDC AI, 0-5 VDC AO, DI, DO
4 2 AO (0-20 mA), 2 DI, 2 DO No prewiring
G Cable Gland - Left Connector Inch NPT Left Connector
N Inch NPT Left Connector Blank Plug Right Connector
M NPT-Metric - Left Connector Omni Antenna
P Blank Plug Left Connector Surface Mounting Bracket
X None
G Cable Gland Right Connector
N Inch NPT Right Connector
M NPT-Metric - Right Connector
P Blank Plug Right Connector
X None
1 Omni Antenna
N N Connector
F Surface Mounting
P Pole Mounting
Gateway Ordering
WiYZG- M N * * * * * D 0 * N * N WiYZ Gateway
F FCC/IC Order Code Example
C Australia
WiYZG-MNFAZ1WD01NFN
E ETSI/CE
A ISA100 Mesh Radio FCC/IC Approval
N No Mesh Radio ISA100.11a Mesh
A GSM/GPRS EDGE (AT&T) Verizon Cellular
Z CDMA 1xRTT (Verizon) 900 MHz entraNET
N No Cellular WiFi
1 900 MHz MDS entraNET 10-30 VDC Power
2 2.4 GHz MDS entraNET Modbus Protocol, FTP
3 900 MHz MDS entraNET - Australia General UL Peripheral Connections
N No MDS Radio Surface Mount Brackets
W 802.11b/g WiFi Radio
N No WiFi Radio
1 Standard Peripheral Connections
2 Class 1 Division 2 Peripheral Connections
F Surface Mounting Brackets
P Pole Mounting Brackets

Buy MDS WiYZ online at GEDigitalEnergy.com/onlinestore

060811-v14
GEDigitalEnergy.com