You are on page 1of 5

HV 350

Product description
HV350 series mini design frequency inverter is upgrade
version of HV850 series frequency inverter. Using advanced
current vector control algorithm and better hardware
platform HV350 can be widely used in plenty of applications
which need tiny installation space. With the advanced
design, high quality and reliability, HV350 series inverter will
bring the users a whole new experience for industrial micro
applications. New design concept for expansion keyboard
makes customers more options to meet separate installation
H from cabinet to machine.

At a glance

Advanced motor control technology


Sensorless Vector control and V/F control with different input
voltage(220V single phase/220V 3 phase/400V 3 phase)
High starting torque characteristics
Rich and flexible I/O accesses and field bus options

Additional information Customer benefits


Product description............K-01
At a glance........................ K-01
Customer benefits..............K-01
Specificaiton..................... K-02
Model Definition.................K-03
Mini design housing suitable for micro automation such as
Dimensional Drawing......... K-04
Connection Diagram.......... K-05
packaging machine, labeling machine, conveyor belt etc.
Upgrade IO can meet more simple application requirement
without controller(PLC)
Programmable DI/DO/AI/AO as well as RS485 Modbus RTU
make easy communication with other devices

www.hncelectric.com/HV350
For more information, please enter the link or scan the code via mobile devices and get direct
access to technical date,manual,application examples and much more.

K-01 www.hncelectric.com subject to change without notice


HV 350

Specificaiton

Items Description
Three phase 380V, 220V (Max output voltage is equal
Rated Output Voltage
to input voltage)
Output Max continuous current 100% rated output current
150% rated current for 1minutes,
Overload ability
180% rated current for 2 seconds
Output frequency 0Hz~400Hz

Rated input voltage Three phase: 380V20%, Single phase 220V20%,


Input
50~60Hz5%

AVR Function When AVR function is enableoutput voltage is


stable under input voltage fluctuation
Modulation modes Optimized space voltage vector PWM modulation
Control mode Sensorless Vector control; V/F control.
Running command input modes Panel control, external terminal control, control by
serial port of host computer
Ten kinds of main frequency setting modes, five
Control performance kinds of Auxiliary frequency setting modes. Several
Speed setting mode
combination kinds of main frequency setting modes

Speed setup resolution


and Auxiliary frequency setting modes.
Digital setting: 0.01Hz
H
Analog setting: highest frequency0.1%
Voltage/Frequency characteristic Rated voltage: 50-100%,adjustable, Base frequency
50Hz, adjustable, five type V/F curves
Acc/dec characteristic 0.1seconds~3600 seconds
Braking torque >20% rated torque
Reference voltage output 1 channel, +10V, 50mA
Control voltage output 24V, 200mA
1 channel, 0~20mA DC10 bit;
Analog input
1 channel, 0~10 V DC10 bit
1 channel, 0~10V, output programmable, various
Analog output
output selectable

Control I/O signal 6 programmable channels, 30 kinds of functions can


be selected, such as Run forward/reverse, Jog
Programmable terminal input
forward/reverse, multi-step speed selection, multi-
step Acc/Dec time, free run to stop, voltage/current
switch, etc.

Open collector output 1 channel, 20 optional running states, the maximum


output current is 50mA

Programmable relay output 1 channel, 20optional running states, contact


capacity: 250V AC /3A or 30V DC /1A
Serial port RS-485 port
Current limit, torque boost, speed trace, DC
braking, restart after power failure, slip
compensation, auto fault reset, high/low limit
frequency, starting frequency, jump frequency,
Standard function frequency gain, Carrier frequency adjustment,
Acc/Dec mode selection, voltage meter output,
current meter output, multi-frequency operation,
programming operation, traverse operation, PI
close loop operation, proportional control, remote
control, FWD/REV dead time, etc.

subject to change without notice www.hncelectric.com K-02


HV 350

Items Description
Over voltage, low voltage, over current, current limit,
Protection function overload, over heat, electronic thermal overload
relay, over voltage stall, data protection, etc.
15 kinds of parameters, such as frequency setting,
output frequency, output voltage, output current,
Display 4-digit display (LED) motor speed, output torque, digital value terminals,
program menu parameters and 33kinds of Fault
codes
Indicator (LED) Parameter unit, RUN/STOP state, etc.
Inside, low than 1000m, free from dust, corrosive gas
Environment and direct sunlight
Operating environment -10+40 (bare machine: -10~+50), 20%
Ambient temperature
90%RH, no condensing
Vibration Lower than 0.5g
Storage temperature -25~+65
Installation Wall mounted

Protection class Ip20


0.75 kW and below: enclosed self-cooling
Cooling
H Others: forced cooling.

Model Definition

HV 350 - R75 G3
Code Voltage
G1 single phase 220V
G2 3 phase 220V
G3 3 phase 380V

Code Matching motor


R75 0.75kW
2R2 2.2kW

HV 350 Series Inverter

Frequency Inverter Rated Output Rated Input Rated Output Motor power
Model Input Voltage Power(kW) Current (A) Current (A) kW
HV350-R40G1 0.4 5.5 2.6 0.4
HV350-R75G1 single-phase220V 0.75 9.2 4.5 0.75
HV350-1R5G1 15% 1.5 14.5 7.5 1.5
HV350-R40G2 0.4 5.5 2.6 0.4
HV350-R75G2 three-phase220V 0.75 9.2 4.5 0.75
HV350-1R5G2 15% 1.5 14.5 7.5 1.5
HV350-R75G3 0.75 3.5 2.5 0.75
three-phase380V
1.5 3.8 1.5
HV350-1R5G3 15% 6.2
HV350-2R2G3 2.2 9.2 5.5 2.2

K-03 www.hncelectric.com subject to change without notice


HV 350

Dimensional Drawing

Outline and mounting dimension (mm) Approximate weight


Voltage class Inverter model
(kg)

HV350-R40G1
W D H W1 D1 H1 d
H
single phase 220V HV350-R75G1 2.0
HV350-1R5G1
HV350-R40G2
three phase 220V HV350-R75G2 2.0
101 126.5 152 89 120 140 4.8
HV350-1R5G2
HV350-R75G3
three phase 400V HV350-1R5G3 2.0
HV350-2R2G3

Product outline, mounting dimension, and weight

subject to change without notice www.hncelectric.com K-04


HV350

Connection Diagram

Braking resistor

B
Circult braker
R U Morotr
AC
Three phase AC S V M
power supply
T W
Mortor grounding
Power grounding Main
Main circult
circult

Multi function input 1


Control
Controlcircult
circult
X1 (DC (DC 0 AO1
~ 10V)
0~10V)AO1
Multi function input 2 Analog output 1
X2 GND
GND
H Multi function input 3

Multi function input 4


X3
X4
Multi function input 5
X5
Multi function input 6
X6
GND
1
A1
Relay output
cC1
1 250V AC/1A
B1 30V DC/1A
B1

+10V
+10VAnalog
A input reference voltage

10k AI1 (DC0~10


0
~ 10V)
P
GND
MO1
MO 1

Analog inputP AI2(


AI2DC0~20
0
~ 20mA ) Open collector output
Analog inputP MCM
MCM
485 terminal resistor selecting switchCM
CM
485
ON
Modbus 485+
P
communicationP
communication
485-
RS485 OFF
GND

Shielding
P Twisted shielding
cable cable

K-05 www.hncelectric.com subject to change without notice