You are on page 1of 8

DISEO DE COLUMNAS

Columna 60 cm x 60 cm DATOS:

P (Ton) V (Ton) M (Ton-m) fc= 280


Peso Propio 67.12 1.64 2.62 fy= 4200
Carga muerta 56.96 1.12 1.8 A= 60
Carga viva 17.94 0.78 1.24 B= 60
Carga viva de techo 1.82 0 0 L= 5.00
Sismo 16.48 10.04 28.84 Hc= 3.00
= 2%
P (Ton) V (Ton) M (Ton-m) re= 4
CM 124.08 2.76 4.42 estribo= 0.95
CV 19.76 0.78 1.24 1" 2.54
SISMO 16.48 10.04 28.84 7/8" 2.22

RESISTENCIA REQUERIDA

P (Ton) V (Ton) M (Ton-m)


1.4CM+1.7CV 207.30 5.19 8.30
0.9CM+1.25EQX 131.45 14.53 38.59
0.9CM-1.25EQX 91.90 -9.56 -30.63
1.25(CM+CV)+EQX 196.28 14.47 35.92 DISEO
1.25(CM+CV)-EQX 163.32 -5.62 -21.77
0.9CM+EQX 128.15 12.52 32.82
0.9CM-EQX 17.78 0.70 1.12

ACERO N VARILLAS ACERO


COLUMNA= Ast= 72.00 18 41" 5.07
147/8" 3.88

DIAGRAMA DE INTERACCION CON FACTOR DE DISEO


Pu= Pn = 0.65 ESTRIBADOS
Mu= Mn = 0.70 ZUNCHOS

Ast= 74.6
As1= 25.66
As2= 7.76
As3= 7.76
As4= 7.76
As5= 25.66
x= 7.23

FALLA POR CARGA AXIAL PURA

Pno= 921892.16 kg 921.89


Puo= 599229.90 kg 599.23 tn por el factor de diseo

FALLA BALANCEADA 1= 0.85 Yo= 30

Cb= 31.64 cm

ab= 26.89 cm

fs1= 4.82 = 4.2 tn/cm^2


fs2= 3.16 tn/cm^2
fs3= 0.31 tn/cm^2
fs4= -2.53 tn/cm^2
fs5= -4.20 tn/cm^2

Cs1= 107.77 tn
Cs2= 24.48 tn
Cs3= 2.41 tn
Ts4= -19.67 tn
Ts5= -107.77 tn
Cc= 383989.20 kg 383.99 tn

Pnb= 391.21 tn
Pnb= 254.29 tn por el factor de diseo

Mnb= 12144.88 tn/cm 121.45 tn/m


Mnb= 78.94 tn/m por el factor de diseo
e= 0.310 m

FALLA FRAGIL CCb

C= 40 cm

a= 34 cm

fs1= 5.07 = 4.2 tn/cm^2


fs2= 3.75 tn/cm^2
fs3= 1.50 tn/cm^2
fs4= -0.75 tn/cm^2
fs5= -2.07 tn/cm^2

Cs1= 107.77 tn
Cs2= 29.10 tn
Cs3= 11.64 tn
Ts4= -5.82 tn
Ts5= -53.04 tn
Cc= 485520.00 kg 485.52 tn

Pnf= 575.17 tn
Pnf= 373.86 tn por el factor de diseo

Mnf= 10659.65 tn/cm 106.60 tn/m


Mnf= 69.29 tn/m por el factor de diseo
e= 0.185 m

FALLA DUCTIL CCb

C= 25 cm

a= 21.25 cm

fs1= 4.51 = 4.2 tn/cm^2


fs2= 2.40 tn/cm^2
fs3= -1.20 tn/cm^2
fs4= -4.80 tn/cm^2 -4.2 tn/cm^2
fs5= -6.91 tn/cm^2 -4.2 tn/cm^2

Cs1= 107.77 tn
Cs2= 18.62 tn
Ts3= -9.31 tn
Ts4= -32.59 tn
Ts5= -107.77 tn
Cc= 303450.00 kg 303.45 tn

Pnd= 280.17 tn
Pnd= 182.11 tn por el factor de diseo

Mnd= 11773.22 tn/cm 117.73 tn/m


Mnd= 76.53 tn/m por el factor de diseo
e= 0.420 m

FALLA POR FLEXION PURA

C= 6 cm
a= 5.1 cm

fs1= -0.22 =
fs2= -9.00 tn/cm^2 -4.2 tn/cm^3
fs3= -24.00 tn/cm^2 -4.2 tn/cm^4
fs4= -39.00 tn/cm^2 -4.2 tn/cm^2
fs5= -47.78 tn/cm^2 -4.2 tn/cm^2

Cs1= -5.65 tn
Cs2= -32.59 tn
Ts3= -32.59 tn
Ts4= -32.59 tn
Ts5= -107.77 tn
Cc= 72828.00 kg 72.83 tn

Pnp= 0.00 tn
Pnp= 0.00 tn por el factor de diseo

Mnp= 4427.70 tn/cm 44.28 tn/m


Mnp= 37.64 tn/m por el factor de diseo

CALCULO DE DISEO CALCULO TEORICO

Pno= 599.23 Mno= 0.00 Pno= 921.89


Pnf= 373.86 Mnf= 69.29 Pnf= 575.17
Pnb= 254.29 Mnb= 78.94 Pnb= 391.21
Pnd= 182.11 Mnd= 76.53 Pnd= 280.17
Pnp= 0.00 Mnp= 37.64 Pnp= 0.00

DIAGRAMA DE INTERACCIN
1000.00
900.00
800.00
700.00
CARGA AXIAL P

600.00 Column C
500.00 DIAGRMA D
DIAGRAMA
400.00
300.00
200.00
100.00
0.00
-40.00 -20.00 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00
MOMENTO Mn
300.00
200.00
100.00
0.00
-40.00 -20.00 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00
MOMENTO Mn
kg/cm2
kg/cm2
cm
cm
m
m
0.02
cm
cm
cm
cm

cm^2
cm^2

cm^2
cm^2 d1= 6.22 cm
cm^2 d2= 15 cm
cm^2 d3= 30 cm
cm^2 d4= 45 cm
cm^2 d5= 53.78 cm
Mno= 0.00
Mnf= 106.60
Mnb= 121.45
Mnd= 117.73
Mnp= 44.28

Column C
DIAGRMA DE DISEO
DIAGRAMA TEORICA

40.00
40.00