You are on page 1of 10

PRDIDAS DE CARGA DISTRIBUIDAS EN LAS VLVULAS DE INTERCEPTACIN V1, V2, V3,

V4, V5, V6
COMPARACIN DE PRDIDAS EXPERIMENTALMENTE
1 mmHg = 133.322368421 Pa

Prueba N VLVULA Q (m3/h) Q (m3/s) Q (m6/s2) p Exper.


(mmHg)
01 0.25 6.94E-05 4.82E-09 1
02 0.50 1.39E-04 1.93E-08 2
03 0.75 2.08E-04 4.34E-08 4
04 1.00 2.78E-04 7.72E-08 6
05
V-1 1.25 11
3.47E-04 1.21E-07
06 1.50 4.17E-04 1.74E-07 18
07 1.75 4.86E-04 2.36E-07 26
08 2.00 5.56E-04 3.09E-07 37
01 0.25 6.94E-05 4.82E-09 4
02 0.50 1.39E-04 1.93E-08 28
03 0.75 2.08E-04 4.34E-08 56
04 1.00 2.78E-04 7.72E-08 80
05
V-2 1.25 125
3.47E-04 1.21E-07
06 1.50 4.17E-04 1.74E-07 182
07 1.75 4.86E-04 2.36E-07 260
08 2.00 5.56E-04 3.09E-07 310
01 0.25 6.94E-05 4.82E-09 1
02 0.50 1.39E-04 1.93E-08 2
03 0.75 2.08E-04 4.34E-08 8
04 1.00 2.78E-04 7.72E-08 39
05
V-3 1.25 58
3.47E-04 1.21E-07
06 1.50 4.17E-04 1.74E-07 90
07 1.75 4.86E-04 2.36E-07 130
08 2.00 5.56E-04 3.09E-07 172
01 0.25 6.94E-05 4.82E-09 15
02 0.50 1.39E-04 1.93E-08 64
03 0.75 2.08E-04 4.34E-08 120
04 1.00 2.78E-04 7.72E-08 260
05
V-4 1.25 410
3.47E-04 1.21E-07
06 1.50 4.17E-04 1.74E-07 611
07 1.75 4.86E-04 2.36E-07 0
08 2.00 5.56E-04 3.09E-07 0
01 0.25 6.94E-05 4.82E-09 1
02 0.50 1.39E-04 1.93E-08 2
03 0.75 2.08E-04 4.34E-08 3
04 1.00 2.78E-04 7.72E-08 10
05
V-5 1.25 13
3.47E-04 1.21E-07
06 1.50 4.17E-04 1.74E-07 20
07 1.75 4.86E-04 2.36E-07 24
08 2.00 5.56E-04 3.09E-07 30
01 0.25 6.94E-05 4.82E-09 1

V-6
02 0.50 1.39E-04 1.93E-08 28
03 0.75 2.08E-04 4.34E-08 86
04 1.00 2.78E-04 7.72E-08 154
05
V-6 1.25 234
3.47E-04 1.21E-07
06 1.50 4.17E-04 1.74E-07 364
07 1.75 4.86E-04 2.36E-07 488
08 2.00 5.56E-04 3.09E-07 680
CEPTACIN V1, V2, V3,
COMPARACION DE PERDIDAS DE VALVULAS - Q
ENTE
Pa 100000

p Exper. 90000
(Pa) 80000
133.322368 70000
266.644737 60000
533.289474
p (Pa)
50000
799.934211
40000
1466.54605
2399.80263 30000
3466.38158 20000
4932.92763 10000
533.289474 0
3733.02632 2.17E-19 1.00E-04 2.00E-04 3.00E-04 4.00E-04 5.00E-04 6.00E-04
7466.05263
CAUDAL (m3/s)
10665.7895
16665.2961
24264.6711
34663.8158
41329.9342 COMPARACION DE PERDIDAS DE VALVULAS - Q^2
133.322368
266.644737 100000
1066.57895
90000
5199.57237
7732.69737 80000 V-1
V-2
11999.0132
70000 V-3
17331.9079
V-4
22931.4474 60000 V-5
1999.83553 V-6
p (Pa)

50000
8532.63158 V-1
15998.6842 40000 V-2
34663.8158 V-3
30000 V-4
54662.1711
V-5
81459.9671 20000
V-6
0
10000
0
133.322368 0
266.644737 0.00E+00 5.00E-08 1.00E-07 1.50E-07 2.00E-07 2.50E-07 3.00E-07 3.50E-07
399.967105
CAUDAL (m6/s2)
1333.22368
1733.19079
2666.44737
3199.73684
3999.67105
133.322368
3733.02632
11465.7237
20531.6447
31197.4342
48529.3421
65061.3158
90659.2105
VALVULAS - Q

V-1
V-2
V-3
V-4
V-5
V-6

5.00E-04 6.00E-04

DE VALVULAS - Q^2

V-1
V-2
V-3
V-4
V-5
V-6
V-1
V-2
V-3
V-4
V-5
V-6
DATOS OBTENIDOS DE LABORATORIO
PRDIDAS EN CAUDALIMETROS O MEDIDORES DE CAUDAL

Prueba N Q (m3/h) Q (m3/s) p VENTURI p DIAFRAGMA p PITOT


(mmHg) (mmHg) (mmHg)
01 0.25 6.94E-05 1 1 1
02 0.50 1.39E-04 5 6 6
03 0.75 2.08E-04 12 9 14
04 1.00 2.78E-04 22 17 24
05 1.25 3.47E-04 36 26 38
06 1.50 4.17E-04 54 32 53
07 1.75 4.86E-04 72 55 72
08 2.00 5.56E-04 100 76 98

PRDIDAS DE CARGA EN EL TUBO DE VENTURI


CARACTERSTICAS DEL TUBO COMPA
Tubo VENTURI DIMETRO MXIMO (m) 0.05
1 mmHg = 133.322368421 Pa DIMETRO MNIMO (m) 0.0115
15000
COMPARACIN DEL VALOR EXPERIMENTAL Y TERICO

Prueba N Q (m3/h) Q (m3/s) p Exper. p Exper. (Pa) p Terico (Pa) 10000


(mmHg)

p (Pa)
01 0.25 6.94E-05 1 133.322 222.873
02 0.50 1.39E-04 5 666.612 891.491 5000
03 0.75 2.08E-04 12 1599.868 2005.854
04 1.00 2.78E-04 22 2933.092 3565.963
0
05 1.25 3.47E-04 36 4799.605 5571.817
0.00E+00
06 1.50 4.17E-04 54 7199.408 8023.417
07 1.75 4.86E-04 72 9599.211 10920.762
08 2.00 5.56E-04 100 13332.237 14263.852

PRDIDAS DE CARGA EN EL TUBO DE DIAFRAGMA


CARACTERSTICAS DEL TUBO COMP
Tubo VENTURI DIMETRO MXIMO (m) 0.05
1 mmHg = 133.322368421 Pa DIMETRO MNIMO (m) 0.01458
12000
COMPARACIN DEL VALOR EXPERIMENTAL Y TERICO 10000
Prueba N Q (m3/h) Q (m3/s) p Exper. p Exper. (Pa) p Terico (Pa)
8000

p (Pa)
(mmHg) 6000
01 0.25 6.94E-05 1 133.322 85.878
02 0.50 1.39E-04 6 799.934 343.513
4000
03 0.75 2.08E-04 9 1199.901 772.905 2000
04 1.00 2.78E-04 17 2266.48 1374.054 0
05 1.25 3.47E-04 26 3466.382 2146.959 0.00E+00
06 1.50 4.17E-04 32 4266.316 3091.621
07 1.75 4.86E-04 55 7332.73 4208.039
08 2.00 5.56E-04 76 10132.5 5496.215

PRDIDAS DE CARGA EN EL TUBO DE PITOT


CARACTERSTICAS DEL TUBO
Tubo VENTURI DIMETRO MXIMO (m) 0.014
CO
1 mmHg = 133.322368421 Pa 14000
p (Pa)

COMPARACIN DEL VALOR EXPERIMENTAL Y TERICO 12000


Prueba N Q (m3/h) Q (m3/s) p Exper. p Exper. (Pa) p Terico (Pa) 10000
(mmHg) 8000
01 0.25 6.94E-05 1 133.322 101.754
6000
02 0.50 1.39E-04 6 799.934 407.018
4000
03 0.75 2.08E-04 14 1866.513 915.789
04 1.00 2.78E-04 24 3199.737
2000
1628.07
05 1.25 3.47E-04 38 5066.25 2543.86
0
06 1.50 4.17E-04 53 7066.086 3663.158 0.00E+
07 1.75 4.86E-04 72 9599.211 4985.965
08 2.00 5.56E-04 98 13065.592 6512.28
COMPARACION DEL VALOR EXPERIMENTAL Y TEORICO -TUBO VENTURI
15000

10000
p (Pa)

p Exper. (Pa)
5000 p Teor. (Pa)

0
0.00E+00 1.00E-04 2.00E-04 3.00E-04 4.00E-04 5.00E-04 6.00E-04
CAUDAL (m3/s)

COMPARACION DEL VALOR EXPERIMENTAL Y TEORICO - TUBO DIAFRAGMA


12000
10000
8000
p (Pa)

6000 p Exper. (Pa)


4000 p Teor. (Pa)
2000
0
0.00E+00 1.00E-04 2.00E-04 3.00E-04 4.00E-04 5.00E-04 6.00E-04

CAUDAL (m3/s)

COMPARACION DEL VALOR EXPERIMENTAL Y TEORICO - TUBO PITOT


14000
p (Pa)

12000
10000
8000
p Exper. (Pa)
6000
4000 p Terico (Pa)
2000
0
0.00E+00 1.00E-04 2.00E-04 3.00E-04 4.00E-04 5.00E-04 6.00E-04
CAUDAL (m3/s)
INSTRUMENTOS EN LOS TUBOS VENTURI, DIAFRAGMA Y PITOT
p Exper. p Exper. (Pa)
INSTRUMENTOS Prueba N Q (m3/h) Q (m3/s)
(mmHg)
01 0.25 6.94E-05 1 133.322
02 0.50 1.39E-04 5 666.612
03 0.75 2.08E-04 12 1599.868
04 1.00 2.78E-04 22 2933.092
Venturi
05 1.25 3.47E-04 36 4799.605
06 1.50 4.17E-04 54 7199.408
07 1.75 4.86E-04 72 9599.211
08 2.00 5.56E-04 100 13332.237
01 0.25 6.94E-05 1 133.322
02 0.50 1.39E-04 6 799.934
03 0.75 2.08E-04 9 1199.901
04 1.00 2.78E-04 17 2266.48
Diafragma
05 1.25 3.47E-04 26 3466.382
06 1.50 4.17E-04 32 4266.316
07 1.75 4.86E-04 55 7332.73
08 2.00 5.56E-04 76 10132.5
01 0.25 6.94E-05 1 133.322
02 0.50 1.39E-04 6 799.934
03 0.75 2.08E-04 14 1866.513
04 1.00 2.78E-04 24 3199.737
Pitot
05 1.25 3.47E-04 38 5066.25
06 1.50 4.17E-04 53 7066.086
07 1.75 4.86E-04 72 9599.211
08 2.00 5.56E-04 98 13065.592
COMPARACION DE PERDIDA DE CARGAS EN LOS TUBOS, VENTURI, DIAFRAGMA Y PITOT

14000
12000
10000
8000 Venturi
p (Pa)

6000 Diafragma
4000 Pitot

2000
0
0.00E+00 1.00E-04 2.00E-04 3.00E-04 4.00E-04 5.00E-04 6.00E-04
CAUDAL (m3/s)
PITOT

Venturi
Diafragma
Pitot