NEMA IP NEMA Definition IP Definition Rating Equivalent
1 IP10 Enclosures constructed for indoor use to 1 = Protected 0 = Not Protected
provide a degree of protection to against solid personnel against incidental contact with foreign objects the enclosed equipment and to provide a of 50mm in degree of protection against falling dirt diameter and greater
2 IP11 Enclosures constructed for indoor used to 1 = Protected 1 = Protected
provide a degree of protection to against solid against vertically personnel against incidental contact with foreign objects falling water drops the enclosed equipment, to provide a of 50mm in degree of protection against falling dirt, diameter and and to provide a degree of protection greater against dripping and light splashing of liquids
3 IP54 Enclosures constructed for either indoor 5 = Protected 4 = Protected
or outdoor used to provide a degree of against dust - against water protection to personnel against incidental Limited to sprayed from all contact with the enclosed equipment; to ingress (no directions - Limited proved a degree of protection against harmful deposit) to ingress falling dirt, rain, sleet, snow, and permitted. windblown dust; and that will undamaged by external formation of ice on the enclosure 3R IP14 Enclosures constructed for either indoor 1 = Protected 4 = Protected or outdoor used to provide a degree of against against water protection to personnel against incidental vertically falling sprayed from all contact with the enclosed equipment; to water drops directions - Limited provide a degree of protection against to ingress falling dirt, rain, sleet, and snow; and permitted. that will be undamaged by external formation of ice on the enclosure
3S IP54 Enclosures constructed for either indoor 5 = Protected 4 = Protected
or outdoor use to provide a degree of against dust - against water protection to personnel against incidental Limited to sprayed from all contact with the enclosed equipment; to ingress (no directions - Limited provide a degree of protection against harmful deposit) to ingress falling dirt, rain, sleet, snow, and permitted. windblown dust; and in which the external mechanism(s) remain operable when ice laden.
4 IP66 Enclosures constructed for either indoor 6 = Totally 6 = Protected
or outdoor use to provide a degree of protected against strong jets protection to personnel against incidental against dust of water from all contact with the enclosed equipment; to directions - Limited provide a degree of protection against to ingress falling dirt, rain, sleet, snow, windblown permitted. dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure 4X IP66 Enclosures constructed for either indoor 6 = Totally 6 = Protected or outdoor use to provide a degree of protected against strong jets protection to personnel against incidental against dust of water from all contact with the enclosed equipment; to directions - Limited provide a degree of protection against to ingress falling dirt, rain, sleet, snow, windblown permitted. dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by thee external formation of ice on the enclosure
5 IP52 Enclosures constructed for indoor use to 5 = Protected 2 = Protected
provide a degree of protection to against dust - against direct personnel against incidental contact with Limited to sprays of water up the enclosed equipment; to provide a ingress (no to 15 from the degree of protection against falling dirt; harmful deposit) vertical. against settling airborne dust, lint, fibers, and flyings; and to provide a degree of protection against dripping and light splashing of liquids. 6 IP67 Enclosures constructed for either indoor 6 = Totally 7 = Protected or outdoor use to provide a degree of protected against the effects protection to personnel against incidental against dust of temporary contact with the enclosed equipment; to immersion provide a degree of protection against between 15cm and falling dirt; against hose-directed water 1m. Duration of and the entry of water during occasional test 30 minutes. temporary submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure.
6P IP67 Enclosures constructed for either indoor 6 = Totally 7 = Protected
or outdoor use to provide a degree of protected against the effects protection to the personnel against against dust of temporary incidental contact with the enclosed immersion equipment; to provide a degree of between 15cm and protection against falling dirt; against 1m. Duration of hose-directed water and the entry of test 30 minutes. water during prolonged submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure
12K knockouts) for indoor use to provide a against dust - against direct degree of protection to personnel against Limited to sprays of water up incidental contact with the enclosed ingress (no to 15 from the equipment; to provide a degree of harmful deposit) vertical. protection against falling dirt; against circulating dust, lint, fibers, and flying; and against dripping and light splashing of liquids 13 IP54 Enclosures constructed for indoor use to 5 = Protected 4 = Protected provide a degree of protection to against dust - against water personnel against incidental contact with Limited to sprayed from all the enclosed equipment; to provide a ingress (no directions - Limited degree of protection against falling dirt; harmful deposit) to ingress against circulating dust, lint, fibers, and permitted. flyings; and against the spraying, splashing, and seepage of water, oil, and noncorrosive coolants.