You are on page 1of 10

Skip to Navigation

Skip to Content

Choose your preferred country site here

Light

Pump

Power

Support

Home
About
Products
Parts
Service
Contact

Home > Products > Pumps > Himax High Head > HH160i

HH160i Features:
The High Head range of pumpsets are fully automatic priming and designed to meet the stringent
demands of the mining, construction and rental industries.

Boasting one of the best shaft stiffness ratios of any automatic priming pump on the market, the
Sykes High Head range provides the reliability to meet market expectations.

In addition the pump can run dry for extended periods due to the mechanical seal assembly
which allows priming with long suction hoses and suction lifts of up to 9m (28 feet).

As fluid levels fluctuate, the pump will snore until the liquid is available for the pump to fully
reprime itself automatically.

Get a Quote

> Check stock availability

Download brochure > Locate Dealer > Enquire about this product

Share this
Tech specs
Pump Curves
Optional equipment
Gallery
Pump Monitoring
Product Support
About Sykes

Pump at a glance
Maximum Suction:
9m/29'
Connections:
200x150
Max Flow l/sec:
188
Maximum Head:
140
Solids Handling:
65
Priming System:
Compressor

Pumpset dimensions
Width:
2010mm/6' 7"
Length:
5100mm/16' 8"
Height:
2396mm/7' 10"
Dry weight:
5600kg

Materials of construction
Pump Casting:
S.G. IRON 400/12
Suction Cover:
S.G. IRON 400/12
Air Seperation Tank:
S.G. IRON 400/12
Bearing Bracking:
S.G. IRON 400/12
Pump Shaft:
431 Stainless Steel
Impeller:
316 Stainless Steel
Wear Plates:
316 Stainless Steel
Mechanical Seal:
Silicon Carbide
N.R.V:
S.G. IRON 400/12

Design details
Pump Description:
End suction type, 2 vane semi open impeller
Suction Flange mm:
200
Delivery Flange mm:
150
Nominal Casting Thickness mm:
20
Solids Handling Size mm:
65
Operating Speed:
MIN: 1400rpm MAX: 2000rpm
Maximum Head m:
140
Maximum Capacity l/sec:
186 L/sec
Engine:
Perkins

Fuel consumption
Fuel Capacity Ltrs/US Gal:
1200 Ltrs
Fuel Consumption:
17 L/hr @ BEP 1400rpm WMR
Useful links

Related products

HH80
HH130i
HH220i

Privacy | Disclaimer | Warranty | Terms and Conditions | Site Map

> About
> Company History
> Mission, Vision & Values
> Careers
> Science of Lighting
> Pump Priming Solutions
> Pump Selector
> Pump Monitoring

> Products
> Lighting Towers
> Pumps
> Generators
> Diesel Engines
> Parts
> Engine Repower - Lighting
> Parts Service Kit
> Parts Enquiry
> Parts Order
> Support Network

> Service
> Maintenance & Service
> Service Booking
> Service Enquiry
> Troubleshooting - Pumps
> Troubleshooting - Lights

> Contact
> Branch Locator
> Media

Perth
12 Hoskins Road, Landsdale
Tel: +61 (0)8 9302 7000

Brisbane
28 Gassman Drive, Yatala
Tel: +61 (0)7 3442 1122

Newcastle
42 Munibung Road, Cardiff
Tel: +61 (0)2 4954 1400

Melbourne
2832 Ventura Pl, Dandenong
Tel: +61 (0)3 8795 6801


Skip to Navigation
Skip to Content

Choose your preferred country site here

Light

Pump

Power

Support

Skip to Navigation Skip to Content AllightSykes Choose your preferred country site here
LightLight WaterPump PowerPower SupportSupport Australia Home About Products Parts
Service Contact Home > Products > Pumps > Himax High Head > HH160i Sykes HH160i
Features: AllightSykes Sykes HH160i Himax Pump The High Head range of pumpsets are fully
automatic priming and designed to meet the stringent demands of the mining, construction and
rental industries. Boasting one of the best shaft stiffness ratios of any automatic priming pump
on the market, the Sykes High Head range provides the reliability to meet market expectations.
In addition the pump can run dry for extended periods due to the mechanical seal assembly
which allows priming with long suction hoses and suction lifts of up to 9m (28 feet). As fluid
levels fluctuate, the pump will snore until the liquid is available for the pump to fully reprime
itself automatically. Get a Quote > Check stock availability Download brochure > Locate Dealer
> Enquire about this product Share this Tech specs Pump Curves Optional equipment Gallery
Pump Monitoring Product Support About Sykes Pump at a glance Maximum Suction: 9m/29'
Connections: 200x150 Max Flow l/sec: 188 Maximum Head: 140 Solids Handling: 65 Priming
System: Compressor Pumpset dimensions Width: 2010mm/6' 7" Length: 5100mm/16' 8" Height:
2396mm/7' 10" Dry weight: 5600kg Materials of construction Pump Casting: S.G. IRON 400/12
Suction Cover: S.G. IRON 400/12 Air Seperation Tank: S.G. IRON 400/12 Bearing Bracking:
S.G. IRON 400/12 Pump Shaft: 431 Stainless Steel Impeller: 316 Stainless Steel Wear Plates:
316 Stainless Steel Mechanical Seal: Silicon Carbide N.R.V: S.G. IRON 400/12 Design details
Pump Description: End suction type, 2 vane semi open impeller Suction Flange mm: 200
Delivery Flange mm: 150 Nominal Casting Thickness mm: 20 Solids Handling Size mm: 65
Operating Speed: MIN: 1400rpm MAX: 2000rpm Maximum Head m: 140 Maximum Capacity
l/sec: 186 L/sec Engine: Perkins Fuel consumption Fuel Capacity Ltrs/US Gal: 1200 Ltrs Fuel
Consumption: 17 L/hr @ BEP 1400rpm WMR Useful links Related products HH80
AllightSykes Sykes HH80 Himax Pump HH130i AllightSykes Sykes HH130i Himax Pump
HH220i AllightSykes Sykes HH220i Himax Pump AllightSykes Privacy | Disclaimer | Warranty
| Terms and Conditions | Site Map > About > Company History > Mission, Vision & Values >
Careers > Science of Lighting > Pump Priming Solutions > Pump Selector > Pump Monitoring >
Products > Lighting Towers > Pumps > Generators > Diesel Engines > Parts > Engine Repower -
Lighting > Parts Service Kit > Parts Enquiry > Parts Order > Support Network > Service >
Maintenance & Service > Service Booking > Service Enquiry > Troubleshooting - Pumps >
Troubleshooting - Lights > Contact > Branch Locator > Media Perth 12 Hoskins Road,
Landsdale Tel: +61 (0)8 9302 7000 Brisbane 28 Gassman Drive, Yatala Tel: +61 (0)7 3442 1122
Newcastle 42 Munibung Road, Cardiff Tel: +61 (0)2 4954 1400 Melbourne 2832 Ventura Pl,
Dandenong Tel: +61 (0)3 8795 6801 Allight FG Wilson Perkins Sykes Skip to Navigation Skip
to Content AllightSykes Choose your preferred country site here LightLight WaterPump
PowerPower SupportSupport Australia

You might also like