You are on page 1of 2

Plant Item No.

T-201 P-201 - E-201 C-201 P-203 - - - E-205 - C-202 - - Legend


Caustic s. Caustic s. - Caustic s. Caustic s. Recycle - - - Process s. - Chill water - -
Description storage pump cooler scrubber pump cooler scrubber Stream
100 PAH
Number Alarm
No. Required 1 1 - 1 1 1 - - - 1 - 1 - -
Matl. Of Constr. Mild steel Cast iron - Copper Mild steel Cast iron - - - Copper - Carb steel - -
Control Element
Capacity (m3) 428.7 N/A - 3.517 - - - - 6.765 - - Relief to
P(I)C (I Indicator)
Heat Trans. Area (m2) N/A N/A - 4.819 N/A N/A - - - 31.87 - N/A - - System
Height: - Height: - - - - Height: - - RTS
9.900 5.361 10.31 N
Overall Dimension (m) Utility Code Relief to
Diameter: Diameter: Diameter:
7.425 0.9140 0.9140 Atmosphere
Number of Utility RTA
Operating Temp. (C) 20 20 - 45 45 32 - - - 126 - 44 - - 2-1
Stream
Operating Press. (bar) 4.4 6.0 - 6.0 1.8 6.0 - - - 1.5 - 1.5 - -
Design Press (bar) 4.8 6.5 - 6.5 2.0 6.5 - - - 1.8 - 1.7 - - cxcxczxcvxzvcvxcv
Absorbed Power (kW) N/A 0.5802 - N/A N/A 0.8517 - - - N/A - N/A - - Transmitter
Heat Load (kW) N/A N/A - 23.54 N/A N/A - - - 541.53 - N/A - - TT

80 C Stream Temperature
4.2 bara Stream Pressure

Service Identification Material Abbreviation


Code Service Code Material
N Nitrogen
NG Natural Gas
HP High Pressure Steam
LP Low Pressure Steam
C Condensate
CW Cooling Water
IFW Industrial Fresh Water
BFW Boiler Feed Water
WW Waste Water
E Electricity
Process Notes

There is no pressure drop across heat exchanger E-205. In


reality there should be a pressure drop of 0.2 bar.

Heat exchanger E-201 and pump P-203 should be the other


way around.

Pump P-201 is not in the simulation but is present on the PFD


because Chemcad does not account for feed flow pressure.

Calculated/Drawn By: Vlad Moraru

Date: 15/04/2017 Sheet 1 of 2


Plant section AREA 200
Plant CM-1
Works
University Of Surrey
Department Of Chemical and Process
Engineering
Process Flow sheet / Flow Diagram
Project No. Ser. No. Rev.
Plant Item No. P-202 - E-202 - P-204 C-203 - - E-204 P-205 E-203 D-201 - - Legend
Column - Column - Bottoms Methanol - - Column Reflux Column Reflux - -
Description feed pump preheat pump column reboiler pump condenser drum Stream
100 PAH
Number Alarm
No. Required 1 - 1 - 1 1 - - 1 1 1 1 - -
Matl. Of Constr. Cast iron - Copper - Cast iron Mild steel - - Copper Cast iron Copper Mild steel - -
Control Element
Capacity (m3) - - 12.96 - - 1.158 - - Relief to
P(I)C (I Indicator)
Heat Trans. Area (m2) N/A - 99.97 - N/A N/A - - 35.69 N/A 25.13 N/A - - System
- - Height: - - Length: - - RTS
44.38 2.368 N
Overall Dimension (m) Utility Code Relief to
Diameter: Diameter:
0.6098 0.789 Atmosphere
Number of Utility RTA
Operating Temp. (C) 66 - 112 - 122 112 - - 126 74 86 86 - - 2-1
Stream
Operating Press. (bar) 2.1 - 2.1 - 2.5 2 - - 2.0 2.9 1.7 1.7 - -
Design Press (Bar) 2.5 - 2.5 - 3.0 2.2 - - 2.4 3.5 2.0 2.0 - - cxcxczxcvxzvcvxcv
Absorbed Power (kW) 1.251 - N/A - 0.1594 N/A - - N/A 0.2229 N/A N/A - - Transmitter
Heat Load (kW) N/A - 282.7 - N/A N/A - - 968.1 N/A 910.9 N/A - - TT

80 C Stream Temperature
4.2 bara Stream Pressure

Service Identification Material Abbreviation


Code Service Code Material
N Nitrogen
NG Natural Gas
HP High Pressure Steam
LP Low Pressure Steam
C Condensate
CW Cooling Water
IFW Industrial Fresh Water
BFW Boiler Feed Water
WW Waste Water
E Electricity
Process Notes

Calculated/Drawn By: Vlad Moraru

Date: 15/04/2017 Sheet 2 of 2


Plant section AREA 200
Plant CM-1
Works
University Of Surrey
Department Of Chemical and Process
Engineering
Process Flow sheet / Flow Diagram
Project No. Ser. No. Rev.

You might also like