Purpose:
Checks correct cabling between the tributary ports and the DDF
SDH STM-N
TEST NE Loopback
SET
RX (BER measurement)
NE CONTROL
COMPUTER
DDF
Loopback tributaries
Figure 1
Procedure:
1. Configure NE to perform add-drop function on all installed tributary ports. Associate each
tributary with different VC-12 path within STM-N line signal. Do not enable trail trace
identifier.
2. Configure SDH test set as follows:
a. Set mapping type to VC-12 framed; PRBS test pattern 2x10-15.
b. Transmit test pattern in path under test.
3. Perform BER measurement (use 1min test period). Check that received signal at SDH test set is
error free.
4. Repeat steps 2 and 3 for all paths in the transmitted STM-N line signal.
1
2. Verifying network elements internal clock accuracy
Purpose:
Test the accuracy of the internal timing of the SDH equipment. To be performed in the NE where
external 2 MHz/Mbps clock is to be connected or where external reference clock is available.
SDH STM-N
TEST NE Loopback
SET
RX STM-N line with
frequency offset
2Mhz
clock
NE CONTROL
COMPUTER
DDF
Loopback tributaries
Figure 2
Procedure:
2
3. Verifying protection switching
Purpose:
This is to check if network elements automatic protection switching complies with ITU-T standard of
50ms. To be perform where NMS computer is located.
NE
NE NE
NE
NM
S
SDH TEST SET
Figure 3
Procedure:
1. Connect the test set to the PDH or SDH drop/insert port of the ADM. Loopback at the far end.
Create a VC-12 trail with path protection.
2. Select the transmitter PDH tributary interface rate or SDH tributary interface rate. Select the
required test pattern. Use Manual start/stop gating. Initiate the measurement.
3. Verify that the test set receives no alarms or errors.
4. Activate the protection switch using the NMS of by disconnecting the fiber from the working
section.
5. Measure and record the result for the service disruption time.
3
4. SDH Optical output jitter
Purpose:
SDH
TEST NE
SET STM-N jitter received
Figure 4
Procedure:
4
5. Measuring pointer adjustment jitter
Purpose:
STM-N signal
SDH
TEST NE
SET
2Mhz
clock PDH
TEST
SET
Figure 5
Procedure:
1. Connect the SDH and PDH test set to the network element under test as shown.
2. Configure SDH test set as follows.
a. Set STM-N line rate; mapping type, VC-n test channel, and PRBS test pattern,
b. Set frequency offset of PDH payload to any in range value (0 - 50ppm).
c. Set-up and run G.783 AU/TU pointer sequence A.
3. Configure PDH test set as that of the SDH Tx mapped payload.
a. Set test timing controls to Single, 20 sec.
b. Set receiver to measure UPI-p.
c. Set jitter measurement filter to LP+HP1
4. Verify that no alarms and errors are detected by the PDH receiver.
5. Measure and record peak to peak jitter from 10 consecutive measurement periods.
6. Change filter setting to LP + HP2.
7. Repeat above procedure.
5
6. De-mapping jitter
Purpose:
SDH
TEST NE
SET
2Mhz
clock PDH Measures jitter on the de-mapped
TEST PDH test signal
SET
Figure 6
Procedure:
6
7. Jitter Tolerance Test
STM-N Line
SDH
TEST NE
SET
2Mhz
clock PDH PDH test signal
TEST Error free 2Mbps signal with no
SET offset.
Figure 7
Procedure: