PROCON JEFFREY - FIELD INSTALLATION

PAGE DESCRIPTION: STEERING MODE SELECTOR VALVE - REPLACEMENT OF HYRAFORCE WITH ARGO-HYTOS
FI-01

The purpose of this document is to outline the steps required to replace the former (HydraForce)
steering mode selector valve with the updated (Argo-Hytos) steering mode selector valve.

STEP 1 - With unit parked on flat stable ground, open


the hood.

STEP 2 - Remove the operator compartment steering valve


cover bolts (x9), and set cover and bolts aside for
reinstallation at a later step. Fig. FI101

Fig. FI103

!
CARE MUST BE TAKEN WHEN DRILLING/CUTTING
TO ENSURE HOSES/CABLES ARE TIED UP AND
ARE OUT OF THE WAY. FAILURE TO DO SO MAY
CAUSE DAMAGE TO HOSE ASSEMBLIES

3
STEP 6 - Mark & drill/cut the 2x 8" and
Fig. FI101 1
1x 1 2 " holes in the operators compartment
as shown: (Fig. FI104)
STEP 3 - Remove the control knob and collar from the
3
HydraForce valve by removing the single pan-head 215 16 in 8 in (2x Typ.)
screw from the knob, and the 2 set screws from the
collar. Discard these parts.
Edge of operator
STEP 4 - Mark/Tag the 4 hydraulic lines as shown for later compartment
connection to Argo-Hytos valve assembly:
(Fig. FI102)
11 2 in
C
DETAIL C

Edge of operator
13 compartment
3 16 in
Fig. FI102
51 2 in
STEP 5 - Detach the hydraulic lines from the valve and
remove the valve/bracket from the operators D
compartment by removing the 2x bolts as
shown: (Fig. FI103)
DETAIL D 11 2 in

REV A JUNE 2013