You are on page 1of 15

* * * ALL ORANGE CELLS MUST BE FILLED

(lb/cf)
(lb/cf)
(lb/cf)

Changes in Total Concrete Weigh

(lb)

(lb)
(lb)

Soil and Concrete Weights


(lb)
(lb)
(lb)

(lb)
(lb)

(lb)
Manhole

* * * ALL ORANGE CELLS MUST BE FILLED * * *

Values for f, Ka, and e can be found in Tables 1, 2, and 3 in the accompanying document.

Disclaimer: Use of this calculator does not guarantee the proper function or performance
of any product manufactured in accordance with the date herein. It is the user's
responsibility to ensure their product is designed and manufactured to resist all forces
applied.

Basic Dimensions
Inside Diameter of Manhole (D) 6.00 (feet)
Lid Thickness (L) 12.00 (inches)
Height of Manhole From Top of Base to Top of Lid - This value
includes the height of the lid plus the barrel section, but excludes the 6.00 (feet)
height of the base.
Height of Manhole Barrel Section From Top of Base to Bottom of Lid
5.00 (feet)
(C) - This value is the height of the barrel section.
Depth of Bury (Y) - This measurement extends from the ground
4.00 (feet)
level to the top of the lid.
Wall Thickness (T) 7.00 (inches)
Base Thickness (E) 12.00 (inches)
Lid Diameter - This value is the sum of D and 2*T. 7.17 (feet)
Lid Hole Diameter (H4) 27.00 (inches)
Distance to Groundwater (GW) 9.00 (feet)
(feet)

Customizations
Create Lip:
Extend the base horizontally to create a lip?
12.00 (inches)
If yes, how much? (P) If no, enter a value of 0.
Thickness of lip (E) - This measurement is determined by the value
entered for the base thickness. The lip thickness is equal to that of 12.00 (inches)
the base.
Add Penetrations:
Diameter of Penetration #1 (H1) - Enter a value of 0 if there is no
12.00 (inches)
Penetraion #1.
Diameter of Penetration #2 (H2) - Enter a value of 0 if there is no 12.00 (inches)
Penetraion #2.
Diameter of Penetration #3 (H3) - Enter a value of 0 if there is no 12.00 (inches)
Penetraion #3.

Unit Weights
Unit Weight of Water 62.40 (lb/cf)
Unit Weight of Soil 110.00 (lb/cf)
Unit Weight of Submerged Soil 47.60 (lb/cf)
Unit Weight of Concrete 145.00 (lb/cf)
Unit Weight of Saturated Soil 120.00 (lb/cf)

Changes in Total Concrete Weight Due to


Customizations
Weight of extra concrete due to lip (Weight of extra concrete due to 3720.17 (lb)
P)
Total weight removed due to penetrations in barrel section 341.65 (lb)
Weight of concrete removed due to lid hole 576.53 (lb)

Soil and Concrete Weights


Weight of Soil on Lid 17749.13 (lb)
Weight of Soil on Lip 26621.02 (lb)
Weight of Lid Alone 5272.61 (lb)
Weight of Manhole (Weight of Barrel Section, Lip, and Lid) 23247.10 (lb)

Weight of System Components


Total Weight of Soil 44370.14 (lb)
Total Weight of Concrete 23247.10 (lb)
Total Weight (Manhole and Soil) 67617.25 (lb)

(lb)
(lb)

Ratio of Lateral to Vertical Earth Pressure (Found in Table 2), K a

Uplift Force
Uplift Force 6635.25 (lb)
Safety Factor 2.00
Uplift Force with Safety Factor 13270.51 (lb)
Additional Ballast Required NONE (lb)
(feet)
(inches)

(feet)

(feet)

(feet)
(inches)
(inches)
(feet)
(inches)
(feet)
Soil and Concrete Weights

(lb)
(lb)

(lb)

(lb)

(lb)
2.00
(lb)
(lb)

(lb)

(lb)