Electrical legend

2 5A,intermediate switch(MEM) 1 x 32W Bowl fitting

5A,1-Gang,1-Way switch flush(MEM) 1x 60w ceiling bowl fitting

5A,2-Gang,1-Way switch flush(MEM) 13A Switch socket outlet

5A,1-Gang,2-Way switch flush(MEM) 15A Switch socket outlet

5A,3-Gang,1-Way switch flush(MEM) Water heater switch

5x20w candelia lights Water heater outlet

cctv camera 1 X 32W Double Decorative Wall bracket

S.M.C Ceiling fan cooker control units Proposed Residential


Development at Plot R6,New
Fan regulator 1 X 20W TWIN 600mm POPULAR RANGE FLUORESCENT FITTING COMPLETE
Market Layout, Egbu Road,
WITH TUBE SUSPENDED WITH CHINA LINK 4.5m HIGH FROM Owerri, Imo State .
Direct line Telephone outlet

Direct line Intercom outlet GENERAL NOTE


T.V
Direct line Television outlet
1. The entire installation work shall be carried out in accordance with the latest edition of the Regulatios, published by
T.V T.V Distribution board the installations, published by the institution of Electrical Engineers London.
Engr CHIKA CHRIS OFOMATA
Distribution board 2. The whole of the Electrical installation and all other equipment connected there shall be earthed inconformity with the
above I.E.E Regulations.
TEL. Telephone distribution board
3. All 13A switch sockets bearing, the same serial number as detailed on the relevant drawings shall be ring main circuit,
wired mounting height for all socket to be 1'-6'(450mm) above finished floor level.
1 x 100w weather proof security light fitting HAMZ Projects & Logistics LTD.
Architecture,Building / Civil Engineering,
4. All Lighting switches shall be mounted as specified on the relevant drawing at height of 4'-6'(1350mm) above finished Property Development.
floor level.
2 x 100w weather proof security light fitting
5. Drawing boxes must be provided for every 30'-0'(900mm) run of conduits or at such places where it will be difficult to PLOT 127 IKENEGBU EXTENSION
OWERRI,IMO STATE
run the cable in condui, all materials specified must be approved type or equal.
cctv display Monitor 07037592537
3,3rd Eweka street,
6. On completion, the entire electrical system shall be inspected and tested in accordance with the I.E.E. Regulations. Benin City, Edo State.