-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Primary switched-mode powe r
supply units, slim desig n

MINI POWE R
The wide-range input of 85-264 V A C
and an international approvals portfoli o
provide ideal conditions for worldwid e
use .
Thanks to high operationa l
reliability, Mini Power provides the ful l
output power for more than 20 ms in th e
event of a power cut in complex globa l
networks . 22 .5 67 . 5
With Power Boost, the power reserve ,
reliable startup of heavy loads wit h MINI 24 V DC/1 A MINI 24 V DC/100 W
high inrush currents succeeds. 1 AC_ '" c%l 1 AC NEC Class 2 C)'' Gnus
A preventive function monitoring i s
professionally ensured through an activ e
transistor switching output . CI MI Elm : +
DC OK
L ( .0

N (-)

DC O K

Conn . (IEC) rigid flexible Conn . (IEC) rigid flexible


data [mm2 ] solid stranded AWG data [mm 2 ] soli d strande d AWG
Input 0 .2-2 .5 0.2-2 .5 24-14 M3 Input 0 .2-2.5 0 .2-2 .5 24-14 M3
Output 0 .2-2 .5 0.2-2 .5 24-14 M3 Outpu t 0 .2-2.5 0 .2-2 .5 24-14 M3
Signal 0 .2-2 .5 0.2-2 .5 24-14 M3 Signal 0 .2-2.5 0 .2-2 .5 24-14 M3

Description Type Pcs. Pcs.


Order No . Type Order No.
Pkt . Pkt .

Power supply,
primary switched mod e MINI-PS-100-240AC/24DC/1 29 38 84 0 1 MINI-PS-100-240AC/24DC/C2LPS 28 66 33 6

Technical dat a
Input data
Input nominal voltage rang e 100-240 V A C 100-240 V A C
Input voltage rang e 85-264 V AC / 90-350 V D C 85-264 V AC / 90-350 V D C
Frequency rang e 45-65 Hz / 0 H z 45-65 Hz / 0 H z
Current consumption (with nominal load ) Approx . 0 .5 A (at 120 V AC) / 0 .2 A (at 230 V AC ) Approx . 1 .3 A (at 120 V AC) / 0 .8 A (at 230 V AC)
Inrush current limitation at 25 C Typ. <15 A Typ. < 15 A
Mains buffering (typ . ) >20 ms (at 120 V AC)/> 110 ms (at 230 V AC ) > 20 ms (at 120 V AC) / > 100 ms (at 230 V AC)
Turn-on time after applying the mains voltag e <1 s <1 s
Input fus e Internal 1 .25 AT Internal 3.15 AT
Output data
Nominal output voltage U N/toleranc e 24 V DC 1 % 24VDC1 %
Setting range of the output voltage 22 .5 -28 .5 V D C 22 .5 -26 V D C
Nominal output current I N (up to 60C) / with Power Boost (Boost 1 A/1 .3 A 3.8 A / -
Can be connected in paralle l For redundancy and increased capacit y For redundancy and increased capacit y
Max. power dissipation (idling/nominal load) / efficiency (typ . ) 0.9 W / 4.5 W/> 80 % 2 .5W / 12W / >88 %
Residual ripple / peak switching volt . (20 MHz) with nominal loa d < 100 mVp p < 100 mV p p
Signaling
DC OK (active : U00t> 0 .9 x UN - High signal ) +24 V signal / max. 20 m A +24 V signal / max . 20 m A
LED (Uout < 0 .9 x U N 0 LED flashes ) LED gree n LED green L
Dimensions / weight
Dimensions W x H x D 22 .5 x 99 x 114,5 m m 67 .5 x 99 x 114,5 m m E
Weigh t Approx. 0 .2 k q Approx . 0 .4 kg

General data
Installation position On horizontal DIN rail NS 35 in acc . with EN 60 71 5
Assembly instruction s Can be aligned : - vertical with spacing % 5 c m
- horizontal with zero spacin g
Connection type COMBICON screw/plug connectio n
Degree of protection / Protection class IP20 / Class 2 (in an enclosed control cabinet )
MTBF (Mean Time Between Failure ) > 500 Th . h in acc . with IEC 1709 (SN 29 500 )
Type of housin g Polyamide PA, color : green
Climatic data
Ambient temperature (operation/storage ) -25"C to +70C (> +60C derating) / -40C to +85 C
Humidity Up to 95% at 25C, no condensation
1 Ratings / standard s
Insulation voltage input/outpu t 2 kV (routine test) / 4 kV (type test )
Electrical safety, safety transforme r EN 60 950 / VDE 0805 (SELV), EN 61 558-2-1 7
Electronic equipm . for electrical power installations EN 50 178 / VDE 0160 (PELV)
Safe isolatio n DIN VDE 0100-410, DIN VDE 0106-101 0
UL approvals (AC input voltage / up to +60'C ) UL/C-UL listed UL 508
UL/C-UL recognized UL 60 95 0
Limitation of output powe r NEC Class 2 (MINI 24 V/100 W )
Limitation of mains and harmonic currents In acc . with EN 61 000-3-2
Electromagneticcompatibility CE compliance with EMC directive 89/336/EEC

374 Phoenix Contact



MINI 24 V DC/4 A MINI 1015 V DC/2 A MINI 1015 V DC/8 A


1AC us

L(+ )
6( .0 . =
Nc 0 1-- 2.71_ LS
NC O l/ O +
N(-)

Conn . (IECI rigi d flexible K,i Conn . (IEC) rigid flexibl e Conn. (IECI rigid flexible
AWG data [mm ] solid stranded AW G
data [mm2] soli d stranded AW G data [me] solid stranded
24-14 M3 Input 0 .2-2 .5 0 .2-2 .5 24-14 M 3 Input 0.2-2 .5 0 .2-2 .5 24-14 M 3
Input 0.2-2 .5 0 .2-2 . 5
24-14 M3 Output 0 .2-2 .5 0 .2-2 .5 24-14 M 3 Output 0.2-2 .5 0 .2-2 .5 24-14 M 3
Output 0.2-2 .5 0 .2-2.5
24-14 M3 Signal 0 .2-2 .5 0.2-2 .5 24-14 M3 Signal 0.2-2 .5 0 .2-2 .5 24-14 M 3
Signal 0.2-2 .5 0 .2-2.5
i I
Pcs . Pcs . Pcs.
Type Order No . Type Order No. Type Order No.
Pkt . Pkt. Plot .
I I,

1 MINI-PS-100-240AC/10-15DC/2 29 38 75 6 MINI-PS-100-240AC/10-15DC/8 ' 28 66 29 7 1


M IN I-P S-100-240AC/24 DC/4 2938837

100-240 V A C 100-240 V AC 100-240 V AC


15-264 V AC / 90-350 V D C 85-264 V AC / 90-350 V DC 85-264 V AC / 90-350 V D C
'45. 65 Hz/0H z 45-65 Hz / 0 Hz 45-65 Hz / 0 Hz
Approx. 1 .3 A (at 120 V AC) / 0 .8 A (at 230 V AC) Approx . 0 .4 A (at 120 V AC) / 0.2 A (at 230 V AC) Approx . 1 .3 A (at 120 V AC) / 0 .8 A (at 230 V AC )
Typ .<15 A Typ . < 15 A Typ.<15 A
> 20 ms (at 120 V AC) / > 100 ms (at 230 V AC ) 20 m s > 20 ms (at 120 V AC) / > 20 ms (at 230 V AC )
<1 s <1 s <1 s
Internal 3.15 AT Internal 2 AT Internal 3 .15 AT

24VDC-a1 % 12 V DC J . 1 % 12VDCa1 %
22.5-28 .5 V D C 1-15 V D C 10-15 V DC
4A/5 A 2A/2 .3 A 8 A (10-12 V DC), 6 .6 A (15 V DC)
For redundancy and increased capacit y For redundancy and increased capacit y
For redundancy and increased capacit y
Approx . 2 .5W/12W>88% Approx . 1 W / 7 W > 86% Approx. 2 .5 W / 12 W > 88%
<100 mV, < 100 mV p p <100mV pp

+24 V signal / max. 20 mA + 12 V signal / max . 20 m A


LED green LED green LED gree n

67.5 x 99 x 114 .5 mm 45 x 99 x 114 .5 mm 67 .5 x 99 x 114 .5 m m


Aron .0 -- Approx .0.2kg Approx_0 .4kg
.4k----