Analysis of Typical Connection Details:

Minimum Capacities of Detail 2A and 1A

Bolt Size = 16 mm Shear Capacity = 50.2 kN

No. of bolts = 2 nos Axial Capacity = 60.2 kN


This document is the exclusive property of ANE Consultants Ltd, and must be returned on demand. The document must only be used for the purpose for which it is issued.
The contents of this document are strictly confidential and must not in any circimstances be copied, shown, published or otherwise transmitted to any third party without
the authorisation of ANE consultants Ltd
PROJECT Calc No. SHEET 1 of 2
AREA BY SC CHK DT
TITLE Typical Connection details. DATE 8/8/2015 DATE 8/8/2015

Maximum Load from the structure

Maximum FtEd = 25 kN UR = 0.6579 OK

Axial Capacity FtRd = 38 kN

Maximum FvEd = 30 kN UR = 0.5976 OK

Shear CapacityFvRd = 50.2 kN

Combined Capacity FvEd + FtEd < 1.4


FvRd FtRd

30 + 25 = 1.26 < 1.4


50.2 38

By inspection the connection is OK.

Provide 12 mm thick plate and 6mm fillet weld all around.