You are on page 1of 1

A B C D E F G H I J K

1 10.74b
2 To solve, enter or change the data shown in red.
3
4 Run Goal Seek (Data tab, What-If Analysis)
5
6 Set cell F40 to zero by changing one of the following: D, Q, L, p, Wpump
7
8
9 Enter the Fluid Viscosity and Roughness, Property SI Engr
10 length 5 16.4 ft
11 n (ft2/s) e (inches) e/D Density (lbm/ft3 density 8.60.E+02 53.7 lbm/ft3
12 1.69.E-06 1.97E-02 2.50E-02 53.7 dyn vis 1.35E-04 9.07E-05 lbm/ft s
13 kin vis 1.69E-06 ft2/s
14 Enter Pipe Length, Diameter, Flow Rate, and Pressure Drop mdot 0.5 1.01 lbm/s
15 (Enter a guess for the one you do not know.) Qdot 9.21 gpm
16 dia 2 0.787 in
17 L (ft) D (in) Q (gpm) p1-p2 (psi)
18 16.40 0.79 9.21 0.00 roughness 0.50 0.0197 in
19
20 z -z (ft)
1 2 Ki (nondim) W pump (hp)
21 0.00 0.00 0.0153
22
23 for 100 pipes 1.5323484928 hp
24 1142.66 w
25
26 Friction Factor Calculations:
27
28 V (ft/s) Re f
29 6.07E+00 2.36.E+05 5.34.E-02
30
31
32 Energy Balance per Unit Mass:
33
34 Energy Added (ft2/sec2): p W 246.24 (LHS)
( Z ) g hp
35 Q
36 2
S Energy Loss (ft2/sec2): L V2 V 246.24 (RHS)
37
38
f
D 2

2
K
i
i

39
40 Difference between LHS & RHS: 0.00
41
42
43
44
45
46

You might also like