ESS Series Hybrid Charger & Inverter (Single-phase)
Pure sine wave output, output isolated transformer, safe and stable
Description
ESS series single-phase off-grid inverter adopts integrated design of solar controller, inverter and isolated transformer. The
controller adopts MPPT technology and intelligent battery management design which is very efficient and smart; integrated pure
sine wave inverter and low frequency isolated transformer make it with excellent overload performance, suitable for a variety of
electrical appliances. ESS series controller adopts modular design with flexible configuration; the inverter is with output of
10kVA~20KVA, supplying power for the places without city power e.g. remote areas, pastoral areas, islands, communication base
stations, bringing customer the optimized social, economical and environmental benefits. It supports mains/generator input
(optional), take advantages of old diesel generators, saving initial investment and operation maintenance cost.
AC
DC MPPT2
RS485
PV Array2
Remote Monitor
Mains AC
DC
Mains/DG backup
(optional)
AC Load
DG
220VDC Battery Bank
Technical data
Inverter Output
Battery
General Data
Display LCD+LED
PV Control Module
AC Input
Inverter Output
Battery
General Data
Display LCD+LED
PV Control Module
ETS 10K~60K
Features
Built-in MPPT solar controller, maximize the utilization of solar panels, utilization ratio >95%
Solar controller modular design, hot plug function, flexible configuration, easy capacity expansion
Pure sine wave output, output isolated transformer, safe and stable
Complete protections
Description
ETS series three-phase off-grid inverter adapts integrated design of solar controller, inverter and isolated transformer. The
controller adapts MPPT technology and intelligent battery management design which is very efficient and smart; integrated pure
sine wave inverter and low frequency isolated transformer make it with excellent overload performance, suitable for a variety of
electrical appliances, It supports mains/generator input (optional), take advantages of old diesel generators, saving initial
investment and operation maintenance cost.
ETS series controller adapts modular design with flexible configuration; the inverter output covers 10kVA~60kVA, supply power
for places without city power e.g. remote areas, pastoral areas, islands, communication base stations, bring customer the
optimized social, economical and environmental benefits.
ETS Hybrid
Charger & Inverter (Three-phase)
DC
AC
PV Array1
3/N/PE
DC 380/400/415Vac
PV Array4
AC
Mains
DG
Remote Monitor
AC Load
DC DC
AC
Model ETS 10K ETS 20K ETS 30K ETS 40K ETS 50K ETS 60K
DC Input
Rated power (kW) 30 (1~3pcs*10kW solar controller module) 60 (1~4pcs*15kW solar controller module)
AC Input
AC Output
Crest factor 3
Battery
General Parameters
Display LCD+LED
Weight [without PV module (kg)] 210 230 250 320 350 380
Weight (kg) 11
XPI 0.5kVA~7kVA
Features
MPPT controller, maximize utilization of solar panels
Complete protections
Description
XPI series single-phase off-grid inverter consist of 3 functional modules: solar controller, pure sine wave inverter and insolated
transformer. The controller adapts MPPT technology and intelligent battery management design which is very efficient and smart;
integrated pure sine wave inverter and low frequency isolated transformer makes it with excellent overload performance, suitable
for a variety of electrical appliances. It supports mains/generator input, take advantages of old diesel generators, saving initial
investment and operation maintenance cost.
XPI series is mainly applied in remote animal husbandry, fishery area and big family to solve peoples electricity problems.
DC AC
Optional Models:
XPI 0.5kVA-D M L
DG Battery Bank
Technical data
0.5kVA 0.7kVA 1.0kVA 1.5kVA 2.0kVA 3.0kVA 4.0kVA 5.0kVA 6.0kVA 7.0kVA
Output power (kW) 0.4 0.6 0.8 1.2 1.5 2.5 3.0 4.0 5.0 6.0
AC Charger Parameters
Inverter Parameters
Crest factor 3
General Parameters
Display LCD+LED
Display content PV status, battery capacity, AC input voltage, AC output voltage, load, running status
Complete protections DC & AC overload, under-voltage, SPD, short-circuit, overcharge, overdischarge, over-temperature
Australia
Add: 51 Barry Street, Bayswater
Victoria 3153, Melbourne
T: +61 1300 700 788
E: marketingaus@renesola.com
Europe
Add: Lyoner Strae 15
60528 Frankfurt am Main, Germany
T: +49 (0) 69 663 78 69 00
E: services@renesola.com
Africa
Add: Unit 2, Rambo Junction,
400 Roan Crescent, Midrand,
1685, South Africa
T: (+27) 010 006 0200
E: supportza@renesola.com
Americas
Add: 1300 Clay Street, Suite 550,
Oakland, CA 94612
T: +(415) 852 7421
E: marketing.us@renesola.com