CONVEYOR SYSTEM

1-1 INCOMNG POWER SUPPLY

a) SINGLE PHASE, AC 240V, 50/60HZ .

1-2 MACHINE POWER ON

a) MEASURE THAT THE VOLTAGE SUPPLIED IS AC240V.


b) MAKE SURE ALL SENSORS, REED SWITCHES, VALVES, RELAY ARE
FUNCTIONING.
c) TURN ON THE MAIN AND SUB BREAKER.
d) PRESS POWER ON ILUMINATED PUSH BUTTON.
e) POWER ON ILP LAMP WILL ON.
f) THE PLC UNIT AND OTHER ELECTRICAL COMPONENTS WILL ON.
g) PLEASE DOUBLE CONFIRM THAT ALL ELECTRICAL COMPONENTS
ARE GOOD IN CONDITION.
h) PLEASE TURN OFF THE MACHINE THERE ARE ANY
ABNORMALITIES.

1-3 MAIN PAGE

TOUCH PANEL WILL SHOW MAIN PAGE AFTER THE MACHINE POWER ON

GOT 4 SELECTION
1. MANUAL CHOOSE MANUAL MODE
2. AUTO - CHOOSE AUTO MODE
3. ALARM GOTO ALARM PAGE

---
4. COUNTER GOTO COUNTER PAGE
5. MESSAGE WILL SHOW CURRENT MESSAGE/ALARM

1-5 MANUAL MODES

SELECT MAN ON MAIN PAGE, TOUCH PANEL CHANGE TO MANUAL PAGE.


IN THIS MODE, WE ARE ALLOWED TO CONTROL MACHINE PARTS
INDIVIDUALLY

SELECT NEXT BUTTON, TOUCH PANEL WILL CHANGE TO MAIN


OPERATION/AUTO PAGE. ON THIS PAGE WE CAN SELECT MANUAL BUTTON

,EX. OR THEN ALL PARTS WILL MOVE INDIVIDUALLY

SELECT ,

,, FOR ON/OFF
CONVEYOR
INDIVIDUALLY
PRESS STATION,
LAST UPPER,
UPPER, MIDDLE
AND LOWER
CYCLINDER

SELECT MANUAL
MODE

---
1-6 SETTING PAGE

SELECT ON OPERATION PAGE WHEN MACHINE NOT IN AUTO


MODE, TOUCH PANEL CHANGE TO SETTING PAGE. IN THIS PAGE WE CAN
CHANGE SETTING FOR AUTO MODE DELAY TIME FOR EVERY PARTS

FOR CHANGE ANY SETTING,TOUCH ANY SETTING NO THEN KEYPAD


WILL APPEARE, THEN KEY-IN NEW VALUE..

1-7 ALARM PAGE

IF ABNORMAL HAPPEN ON ANY PARTS/SEQUENCE MACHINE WILL STOP,

RED TOWER LIGHT ON, AND BUZZER ON.SELECT TO RESET THE

BUTTON AND SELECT ON MAIN PAGE OR ON


OPERATION TO CHANGE TO ALARM PAGE

---
1-8 AUTO MODE

WHEN MACHINE HAS NO ALARM, SELECT ON MAIN PAGE OR

ON OPERATION PAGE, MACHINE WILL CHANGE TO AUTO MODE.

THEN SELECT ON OPERATION PAGE, MACHINE WILL RUNNING ON

AUTO SEQUENCE. SELECT TO STOP THE MACHINE.DURING

MACHINE AUTO RUN, BUTTON AND ON OPERATION PAGE


WILL ON.

1-9 COUNTER PAGE

SELECT TOUCH PANEL WILL CHANGE TO COUNTER PAGE

---
ELECTRICAL

DRAWING

---

You might also like