You are on page 1of 22

Vickers

Flow Controls

Flow Controls
FN, F(C)G, FRG

Released 6/94 685


Table of Contents

FN03/06/10 Model Series


Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

FC/FCG02 Model Series ....


Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Subplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Special Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

FC/FCG03 Model Series


Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Special Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Subplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

FRG03 Model Series


Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Subplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Mounting Adapter Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

2
Introduction

General Data F(C)G Valves (Restrictor) FRG Valves (Bypass)


Vickers temperature and pressure F(C)G valves are pressure and FRG valves are pressure and
compensated flow controls allow precise temperature compensated to provide a temperature compensated to provide a
volumetric control. These valves are precise adjustable flow rate, regardless precise adjustable flow rate regardless of
available with (bypass type) or without of load pressure or temperature load pressure or temperature changes.
(restrictor type) integral relief valves and changes. The valve is adjustable over The valve incorporates an integral relief
are suitable for pressures up to 251 bar the entire flow range. valve with maximum pressure settings of
(3600 psi). 69 bar (1000 psi), 138 (2000 psi), or 207
The optional trim adjustment on the
(3000 psi) and has a flow capacity of 28
FN Valves (Regulator) F(C)G02 size, permits adjustment of
USgpm (106 lpm)
approximately  8% of flow setting
FN valves are ideally suited for a great
when the valve locking device is in a
number of applications requiring flow
locked position. Reverse free flow check
regulation without pressure
option is available.
compensation applications where the
relatively constant nature of the load Tamper resistant adjustment of the
minimizes the need for pressure feed rate is available in the F(C)G02
compensation. They are not intended to size valve.
be used as a shut-off valve.
Valves are suitable for system pressures
up to 248 bar (3600 psi) and cover a
flow range up to 106 lpm (28 USgpm).

3
FN 03/06/10 Model Series Application Data
Functional Symbol Pressure drop for free flow and Fluids and Seals
maximum controlled flow NOTE: 21 and later designs (06 size)
(petroleum oil) approximate and 11 and later designs (10 size)
may be used with a 510%
Model Flow Pressure
concentration of soluble oil in clean
lpm (USgpm) bar (psi) water (not applicable to 03 size). The
15,1 (4) 1,38 (20) oil should be a premium grade soluble
30,3 (8) 2,06 (30) oil designed specifically for heavy duty
FN03 & application. The pH should be
General Information 45,4 (12) 2,76 (40)
FN06 maintained between 8 and 9.5)
The regulator is ideally suited for a great 60,56 (16) 3,79 (55)
number of applications requiring flow 75,7 (20) 4,82 (70) The use of synthetic fire-resistant fluids
regulation without pressure requires a valve with special seals.
38 (10) 0,34 (5) Add the prefix F3 to the model
compensation applications where the 76 (20) 1,03 (15) number when phosphate esters type
relatively constant nature of the load 113,6 (30) 2,4 (35) fluids or its blends are to be used with
minimizes the need for pressure 151,4 (40) 4,13 (60) standard seals.
compensation. It is not intended to be 189,3 (50) 6,89 (100)
used a shut-off valve. FN10 Weights
227,1 (60) 10,3 (150)
265 (70) 13,8 (200) FN03 . . . . . . . . . . . . . . 0,59 kg (1.3 lbs)
To obtain the accurate control required
FN06 . . . . . . . . . . . . . . 1,04 kg (2.3 lbs)
for machine tool feeds and similar 303 (80) 17,2 (250)
FN10 . . . . . . . . . . . . . . . 2.9 kg (6.5 lbs)
applications, pressure and temperature 340,7 (90) 22,4 (325)
compensation is essential. 379 (100) 28,2 (410)
Minimum controlled flow
(approximate) Maximum recommended
Pressure Minimum Flow controlled flow
Diff. FN03 . . . . . . . . . . . 38 lpm (10 USgpm)
cm3/min (in3/min)
bar FN06 . . . . . . . . . 75,7 lpm (20 USgpm)
(psi) Petrol. 5% FN10 . . . . . . . . . . . . 189,3 (50 USgpm)
Oil Soluble
(SAE Oil-in- Max. operating pressure
10W) Water 5% soluble oil-in-water solution
35 410 1638 138 bar (2000 psi)
5% soluble oil-in-water solution
(500) (25) (100)
207 bar (3000 psi)
69 819 2622
(1000) (50) (160)
138 1638 4916
(2000) (100) (300)
207 2458
(3000) (150)

 Applies to 21 and later designs


(06 size) and 11 and later designs
(10 size). Does not apply to 03 size.

4
Model Code

1 2 3 4 5

1 Special Seals 4 Nominal Valve Size 5 Design Numbers


Omit if not required 03 3/8 11 FN-10
F3 Special seals for use with 06 3/4 20 FN-03
phosphate ester type fluids 10 1-1/4 21 FN-06

Installation dimensions remain


2 Type the same for design numbers
FN Flow control, non-compensated 10 through 19, and 20 through 29,
respectively.

3 Straight Threads
See chart in this catalog under FN
Series Installation Dimensions section.
Omit for NPTF pipe threads

5
Installation Dimensions

Inlet connection for free flow


FN03/06
millimeter (inch)

Inlet connection for regulated flow


A connection
B 2 places
22,1
(0.87)
J J
2,3
(0.09)

D Dia. G

4,6 R
(0.18) H Rad. 88,9
Adjusting screw (3.50)
44,5
(1.75)
F
30 C E

Model No. Connection B C D E F G H J


Size A
FN0320 3/8 NPTF Thd.
73,15
73 15 36,5
36 5 31,75
31 75 33,2
33 2 16,51
16 51 19,05
19 05 31,75
31 75 11,18
11 18
FN8S0320 3/416 Straight (2.88) (1.44) (1.25) (1.31) (0.65) (0.75) (1.25) (0.44)
Thd.
FN0621 3/4 NPTF Thd.
88,9
88 9 44,5
44 5 44,5
44 5 47,8
47 8 23,9
23 9 31,8
31 8 25,4
25 4 15,7
15 7
FN12S0621 11/1612 (3.50) (1.75) (1.75) (1.88) (0.94) (1.25) (1.00) (0.62)
Straight Thd.

 For use with SAE straight thread fittings for 1/2 O.D. tubing.  Not recommended
 For use with SAE straight thread fittings for 7/8 O.D. tubing.

38,9 38,1
FN10 (1.53) (1.50)
Inlet connection
for regulated flow
30,2
(1.19)

Inlet connection
for free flow
Wrench Flats

30,2
(1.19) 76,2
59,4 (3.00)
(2.34)
31,75
30 (1.25)
54,8
100
(2.16)
(3.94)

Connection 2 places
Model No. Connection A
FN1011 1-1/4 NFTF thread
FN20S1011 1-5/812 SAE straight thread
 For use with SAE straight thread fittings
Flow adjusting screw
for 11/4 O.D. tubing.
115,8 22,3  Not recommended
(4.56) (0.88)

6
FG/FCG-02 Model Series Application Data

Functional Symbols Valve Locking Pressure Drop


FG02 A standard key-locking device (2 keys Pressure drop for reverse free flow over
furnished) is supplied with these valves. check valve.
An optional device is also available. Volume lpm Pressure
Instead of using the key, the valve is (USgpm) bar (psi)
A B
removed from its mounting to open the
access hole, which is on the front of the 19 (5) 3 (45)
valve. The valve is then returned to its 38 (10) 8 (120)
mounting and the new setting is made. 57 (15) 12 (175 )
FCG02 Then the access hole can be covered
76 (20) 20 (290)
using a screwdriver in the keyhole and
turning clockwise to trip the lock. 95 (25) 30 (440)

Subplate and Bolt Kits NOTE: The pressures in the pressure drop
A B
Valves, subplates and mounting kits chart give approximate pressure drops (DP)
must be ordered separately. when passing a flow of 100 SSU fluids having
For example: 0.865 specific gravity.
For any other viscosity, the pressure drop
One (1) FG-02-1500-5* Valve
General Information (DP) will change as follows:
One (1) FGM-02-20 Subplate
FG/FCG valves provide precise One (1) FGM-02X-20 Subplate Other Viscosity % of DP from table
adjustable control of flow rates in One (1) BKFG-02-640 Mounting (approx.)
hydraulic circuits. They are pressure Bolt Kit (Bolt length = 2 inch)
and temperature compensated to Maximum recommended mounting bolt 75 93
minimize flow variation resulting from torque: 34,5 Nm (305 lb. in.) 150 111
changes in fluid pressure and Mounting bolts, when provided by a
temperature. They can be used in 200 119
customer, must be SAE grade 7,
meter-in, meter-out and bleed-off or better. 250 126
circuits, and are completely
interchangeable with previous designs. Ratings 300 132
Maximum Flow Capacity (based on oil 350 137
Application Guidance viscosity of 150 SUS @ 100 F)
400 141
Flow Adjustment F*G-02-2300-* * -5
Flow rate is adjusted by rotating the dial. 37690 cm3/min (2300 in3/min) Specific gravity of fluid may be obtained
A lettered (A through E ) indicator F*G-02-1500-* * -5 from its producer. For fire resistant
marks approximately 4 1/2 revolutions, 24580 cm3/min (1500 in3/min) fluids, the value is higher than for oil.
from a fully closed to a fully opened F*G-02-300-* * -5
position. 4916 cm3/min (300 in3/min) Fluids and Seals
Maximum throttle openings may be
limited by addition of spacers to the Nominal Reverse Free Flow The use of synthetic fire-resistant fluids
throttle shaft under the selector dial. FCG-02-*- * * -5 only requires a valve with special seals. Add
56,7 lpm (15 USgpm) the prefix F3 to the model number
Trim Adjustment when phosphate esters type fluids or its
This optional feature permits an Maximum Operating Pressure blends are to be used with standard
adjustment of the flow setting when the 248 bar (3600 psi) seals. Refer to Vickers data sheet 694 ,
valve locking device is in a locked
Minimum Pressure Differential Hydraulic Fluids and Temperature
position. Clockwise rotation increases
Between Inlet and Outlet Ports Recommendations for Industrial
the flow, counterclockwise decreases F*G-02-2300-* * -5 Machinery.
the flow. 12 bar (175 psi)
Range of Adjustment F*G-02-1500-* * -5 Weights
F*G021500 & F*G022300 10 bar (150 psi) Valve . . . . . . . . . . . . . . . 3.8 kg (8.5 lbs.)
 8% of flow setting F*G-02-300-* * -5 Subplate . . . . . . . . . . . 2.27 kg (5.0 lbs.)
F*G02300 7 bar (100 psi)
 3% of flow setting

7
Model Code

1 2 3 4 5 6 7 8

1 Special Seals 4 Flow Range 6 Trim Adjustment Option


Omit if not required 300 (2 to 300 in3/min) Omit if not required
F3 Special seals for use with 1500 (10 to 1500 in3/min)
phosphate ester type fluids 2300 (10 to 2300 in3/min)
7 Design Number

2 5
Subject to change
Type Lock Option
F Flow control Blank Standard Lock Installation dimensions remain
C Integral check L Tamper resistant lock the same for design numbers
G Manifold or subplate mounting 50 through 59.

3 Nominal Valve Size 8 Special Feature


02 1/4 S10 Overspeed control
S32 Tamper resistant flow adjustment

8
Performance Data

Typical Pressure Compensation Flow vs Dial Reading


Flow/min Flow/min
cm3 in3 F*G0230050 cm3 in3
F*G0230050
4900 300 4900 300

3300 200
3300 200

1600 100
1600 100
Range

0 0 69 138 207 bar


0 A B C D E
0 1000 2000 3000 psi
Valve Pressure Drop Dial Reading
Flow/min Flow/min
cm3 in3 cm3 in3
F*G02150050 F*G02150050
25000 1500 25000 1500

16400 1000 16400 1000

8200 500
8200 500
Range

0 0 69 138 207 bar


0 A B C D E
0 1000 2000 3000 psi
Flow/min Valve Pressure Drop Flow/min Dial Reading
cm3 in3 F*G02230050 cm3 in3
F*G02230050
49000 3000 49000 3000

33000 2000
33000 2000

16400 1000
16400 1000

00 69 138 207 278 bar


0 A B C D E
0 1000 2000 3000 4000 psi
Valve Pressure Drop Dial Reading

Low Flow Pressure Compensation (Minimum to 69 bar (1000 psi) valve pressure drop)
Model Flow cm3/min (in3/min) Typical Variation (%) Maximum Variation (%)
F*G02300**5* 33 (2) 5% 15%
164 (10) 3% 10%
F*G021500**5* 164 (10) 8% 15%

Flow Variation with Temperature, 27C to 66C (80F to 150F)


Flow cm3/min (in3/min) Average Variation (%) Maximum Variation (%)
32,8 (2.0) 7.5% 15%
163,8 (10.0) 5.5% 10%
1638,7 (100.0) 3.8% 7%
4916 (300.0) 3.0% 5%
12290,3 (750.0) 3.0% 5%
24581 (1500.0) 3.0% 5%

9
Installation Dimensions

FG/FCG02 Model Series


millimeter (inch)

27,6 79,2
(1.09) (3.12)
25,9
(1.02)
2,3
(.09)

41,1 49,3
(1.62) (1.94)
B A 62,0 80,26
(2.44) (3.16)
7,9 27,7
(0.31) (1.09)
Hex key full out position

47,8
Trim adjustment option for (1.88)
F*G02*****T5* Models Selection Dial
Dia.

71,4
(2.81)

0.344 dia thru 0.50 cbore 0.31 deep


4 holes for mounting
6,35 (0.25) rest pin (see subplate for location) 9,7
(see subplate for location) (0.38)
Mounting Surface Revolution indicator Radius

Port B Port A
A

6,35
(0.25) 101,6
(4.00)
Standard lock option
46,7
(1.84)

Unlocked position
38,1
Locked position (1.50)
clearance required to remove key
111,25 95,25
(4.38) (3.75)

Access hole is covered when unit is locked.


To cover access hole, Lock screw is accessible when unlocked. Loosen to
turn clockwise change dial setting.

To uncover access hole, remove cover,compress


spring, and turn counterclockwise

Model No. Port A Port B

FCG-02-*** -5* Inlet connection for regulated flow or outlet Outlet connection for regulated flow or inlet
connection for reversed free flow. connection for reversed free flow.
FG-02-****-5* Inlet connection Outlet connection

10
Subplate

FGM02(X)20
millimeter (inch)

20,6 23,9
(0.81) (0.94)

133,4
(5.25)

114,3
(4.50)

79,5
(3.13)

8,73 (0.344) dia thru 76,2


12,70 (0.50) cbore, (3.00)
0.44 R
7,870 (.31) deep 9,7 22,4
4 places for mounting (0.38) (0.88)

82,55
(3.25) 58,7
(2.31)
101,6
(4.00) 71,4
(2.81) 30,22
0.281 dia. 0.31
(1.19)
deep
for rest pins

System connection D .312518 UNC2B Thd. Thru


Dia. thru 2 holes E 4 holes for mounting valve
NPTF Thd  (from rear)

Subplate D E NPTF
Model Code mm (inch) Thd.
FGM0220 14,27 (0.562) 3/8
FGM02X20 17,48 (0.688) 1/2

 Not Recommended
NOTE:
When the subplate is not used, a machined
pad, as indicated by the shaded area on the
subplate, must be provided for mounting.
The pad must be flat within 0.0005 inch and
smooth within 63 microinch. Mounting bolts,
when provided by the customer, must be SAE
grade 7 or better.

11
Special Features

Over Speed Control, S10 S10 feature adjustment


The flow control hydrostat under zero 62,0 Clockwise rotation
flow conditions is spring offset to its full (2.44) decreases maximum flow
clearance for Counterclockwise rotation
open position. This permits an initial flow increases maximum flow.
greater than the throttle setting, and standard hex key
may result in a momentary over speed 31,75
at the start of the feed cycle. (1.25) 25,9
full out (1.02)
If this condition causes a problem in
position
your application, it can be greatly
reduced with the over speed control
option, S10.
The S10 features a screw which can 27,7
(1.09)
be adjusted to limit the hydrostat
opening to a point just above the
maximum flow requirements of the
system.
Adjust the hydrostat as follows: 22,2 4,78
(0.875) (0.188)
1. Back out the adjusting screw and
hex key
operate the system in the feed mode.
Adjust the throttle setting to the desired
flow rate. Located at right hand side of valve
2. Turn in the adjusting screw until the as you face the dial.
feed rate drops, then back out the
adjusting screw just enough to restore
the original feed rate. The screw will
remain in this position.

Tamper Resistant Flow 6.35 (0.25) Dia. rest pin furnished


Adjustment, S32 Mounting surface
To adjust the flow, the valve must be
removed from its mounting. Install the
valve back on its mounting with the
cover removed using four 5/1618 x 2
long socket head screws (not supplied 84,8
(3.34)
with valve, must be SAE grade 7
max.
or better).
To obtain correct screws, order 5/1618 x 3.25 long
Socket head screw
separately as follows: Four supplied with valve
(1) BKFG02640 mounting bolt kit. Port A
3,05
Loosen set screw in flange of throttle 9,65 R (0.12)
shaft and rotate shaft clockwise to (0.38)
increase flow or counterclockwise to Knurled
decrease flow. When desired flow is set, dial
tighten set screw in flange of throttle.
Port B 82,55
Remove valve from mounting surface,
(3.250)
replace cover and remount valve with Set screw
the four 5/1618 x 3.25 long screw Stop
101,6
provided with the valve. (4.00)

Stop 38,1
(1.50)
76,2
95,25 (3.00)
(3.75)

12
FG/FCG-03 Model Series Application Data

Functional Symbols Valve Locking NOTE: The pressures in the pressure


FCG03 A standard key-locking device (2 keys drop chart give approximate pressure
furnished) is supplied with these valves. drops (DP) when passing a flow of 100
Gauge Gauge SSU fluids having 0.865 specific gravity.
An optional device is also available.
Instead of using the key, the valve is For any other viscosity, the pressure
removed from its mounting to open the drop (DP) will change as follows:
Inlet Outlet access hole, which is on the front of the
valve. The valve is then returned to its Other Viscosity % of DP from table
(approx.)
mounting and the new setting is made.
Then the access hole can be covered 75 93
using a screwdriver in the keyhole and
FG03 150 111
Gauge Gauge
turning clockwise to trip the lock.
200 119
Ratings
250 126
Inlet Outlet Maximum Flow Capacity (based on oil
viscosity of 100 SUS @ 49 C (100 F) 300 132
106 lpm, 8833 ft3/min 350 137
(28 USgpm, 6468 in3/min)
400 141
Nominal Reverse Free Flow
General Information FCG-032822 For any other specific gravity
FC/FCG valves provide precise 5 bar @ 114 lpm (65 psi @30 USgpm) (G1) the pressure drop (DP1 ) will be
adjustable control of flow rates in approximately: DP1 = DP (G1/G).
hydraulic circuits. They are pressure Maximum Operating Pressure
and temperature compensated to 207 bar (3000 psi) Fluids and Seals
minimize flow variation resulting from Maximum Throttle Adj. Torque Req. The use of synthetic fire-resistant fluids
changes in fluid pressure and Adjusting Torque Proportional to Outlet requires a valve with special seals. Add
temperature. They can be used in Pressure the prefix F3 to the model number
meter-in, meter-out and bleed-off 2,26 Nm @210 bar when phosphate esters type fluids or its
circuits. (20 in. lbs. @ 3000 psi) blends are to be used with standard
seals. Refer to Vickers data sheet 694,
Application Guidance Pressure Drop Information Hydraulic Fluids and Temperature
Flow Adjustment Pressure Drop for reverse free flow over Recommendations for Industrial
Flow rate is adjusted by rotating the dial. check valve. Machinery.
A lettered ( A through E ) indicator Pressure Volume
marks approximately 4 1/2 revolutions, bar (psi) lpm (USgpm) Subplate and Bolt Kits
from a fully closed to a fully opened Valves, subplates and mounting kits
3 (45) 19 (5)
position. must be ordered separately.
Maximum throttle openings may be 8 (120) 38 (10) For example:
limited by the addition of spacers to the 12 (175 ) 57 (15) One (1) F(C)G-03-2822 Valve
throttle shaft under the selector dial. One (1) FGM-03SZ-10 Subplate
20 (290) 76 (20)
Spacers are available from Vickers for One (1) BKFG-03-645 Bolt Kit
installation by the user. 30 (440) 95 (25) (Bolt length = 3 inch)
Maximum recommended mounting bolt
Number of Spacers % of Maximum Flow torque: 40 Nm (350 lb. in.)
3 1520 Mounting bolts, when provided by a
customer, must be SAE grade 7,
2 3545 or better.
1 6575
Weights
Use spacers Part No. 211026 Valve . . . . . . . . . . . . . . . . 8.2 kg (18 lbs.)
Subplate . . . . . . . . . . . . 4.5 kg (10 lbs.)

13
Model Code

1 2 3 4 5 6

1 Special Seals 4 Flow Range 6 Special Feature


Omit if not required 28 106 lpm (28 USgpm) S10 Overspeed control
F3 Special seals for use with
phosphate ester type fluids
5 Design Number

2
Subject to change
Type
F Flow control Installation dimensions remain
C Integral check (omit if not required) the same for design numbers
G Manifold or subplate mounting 50 through 59.

3 Nominal Valve Size


03 3/8

Over Speed Control (S10) Dimensions


millimeterm (inch)
The flow control hydrostat under zero
flow conditions is spring offset to its full
open position. This permits an initial flow
greater than the throttle setting, and 38,1
may result in a momentary over speed (1.5)
at the start of the feed cycle. Full out position 15,24
If this condition causes a problem in (0.6)
your application, it can be greatly
reduced with the over speed control
option (S10).
The S10 features a screw which can be 30,2
adjusted to limit the hydrostat opening to (1.19)
a point just above the maximum flow
requirements of the system. S10 feature located
at right hand side of
Adjust the hydrostat as follows: valve as you face dial
1. Back out the adjusting screw and
operate the system in the feed mode.
Adjust the throttle setting to the desired S10 feature adjustment
flow rate. Turn clockwise to decrease maximum flow,
Turn counterclockwise to increase maximum flow
2. Turn in the adjusting screw until the
feed rate drops, then back out the
adjusting screw just enough to restore
the original feed rate. The screw will
remain in this position.

14
Installation Dimensions

FG/FCG03 Model Series


millimeter (inch)

129
(5.08)

75,4 132,6
(2.97) (5.22)

61,9 101,6
(2.44) (4.00)
85,9 6,35
(3.38) 84,6 (.25)
(3.33) Dia.

Inlet port P
129 6,35
(5.08) (.25)
Dia.
.406 Dia. Thru 15 (.59)
50 Cbore 7,9 (.31) Deep
(1.97) 4 places for mounting

Outlet port C
Two keys furnished
Revolution Indicator Access hole covered when unit is locked.
Upon turning key, lock screw is accessible.
Loosen to change dial setting.

47,8
(1.88)

71,3
(2.81) 63,5
(2.50) Outlet pressure gauge test connection
1/2 NPT

Mounting surface
(Seals furnished)
Two rest pins furnished.
See subplate for locations.

Model No. Port P Port C


FCG-03-2822 Inlet connection for regulated flow or outlet Outlet connection for regulated flow or inlet
connection for reversed free flow. connection for reversed free flow.
FG-032822 Inlet connection Outlet connection

15
Subplate

FGM03SZ10
Installation Dimensions
millimeter (inch)
168,0
(6.62)

0.281 Dia. 0.31 deep


for rest pins 2 places
103,12
(4.06)
10,3 (0.406) dia. thru
15,0 (0.59) cbore, 9,7 (0.38) deep
4 places for mounting 0.76 Inlet connection
(0.03)

124,0 101,6
(4.88) 90,4 (4.0)
15,0 84,0
73,2 (3.56)
(0.59) (3.31)
(2.88)

21,3
(0.84)

20,6
(0.81)
.37516 UNC2B thd.
4 places 74,9
(2.95)

101,6
(4.00)

146,1
(5.75)

38,1
(1.50)
20,6
(0.81)

NOTE: When the subplate is not used, a ma-


chined pad, as indicated by the shaded area on
the subplate, must be provided
for mounting. The pad must be flat within
0.0127mm (0.0005 inch) and smooth within 63
microinch. Mounting bolts, when provided by the
customer, must be SAE grade 7 or better.

16
FRG Model Series Application Data

Functional Symbol Pressure Adjustment Pressure Drop Information


Adjust overload relief pressure by Minimum metered flow rates
turning the screw on the side of the
valve. Clockwise rotation increases Operating Approximate
pressure; counterclockwise rotation Pressure Minimum Flow
decreases pressure. bar (psi) cm3/min (in3/min)
Proper adjustment will prevent 35 (500) 82 (5)
excessively high working pressure upon
69 (1000) 164 (10)
pump or other equipment.
103 (1500) 246 (15)
Tank Connection
General Information Connect to tank. Any pressure at this 138 (2000) 327 (20)
This valve is used as a meter-in flow connection must be added to the 172 (2500) 409 (25)
control. It permits the pump to operate pressure setting.
at load pressure and provides precise, 207 (3000) 491 (30)
adjustable control of flow rates in Valve Locking
hydraulic circuits. Some typical uses A locking screw prevents the selected Subplate and Bolt Kits
include controlling the speed of work flow rate setting from being inadvertently
Valves, subplates and mounting kits
spindles, and rates of travel of tool changed.
must be ordered separately.
heads or slides For example:
Interchangeability
The valve is temperature and pressure One (1) FRG03B282* Valve
compensated to reduce flow variation The FRG03*282* can be mounted
One (1) FRGM03Y10 Subplate
with changes in oil temperature and in in place of the FRG03*282*
One (1) BKFG-03-645 Bolt Kit
models.
pressure. An integral, adjustable relief (Bolt length = 3 inch)
valve protects the system against Ratings When a subplate is not used, a
overloads. machined pad (as indicated by the
Maximum Flow Capacity (based on oil
Pump unloading can be accomplished viscosity of 100 SUS @ 49C (120F) subplate shaded area) must be flat
by opening the vent connection to tank, within 0.0127mm (0.0005 inch) and
or by closing the throttle provided that 106 lpm, 8833 ft3/min
smooth within 63 microinch. Mounting
oil under pressure is not trapped in the (28 USgpm, 6468 in3/min)
bolts, when provided by the customer,
outlet port. must be SAE grade 7 or better.
Maximum Relief Valve Pressure
Application Guidance FRG-03B282* . . . 69 bar (1000 psi) Maximum recommended mounting bolt
FRG-03C282* . . 138 bar (2000 psi) torque: 40 Nm (350 lb. in.)
Flow Adjustment Mounting bolts, when provided by a
FRG-03F282* . . 207 bar (3000 psi)
Adjust flow rate by rotating the dial. A customer, must be SAE grade 7,
lettered (A through E) indicator marks Maximum Throttle Adjusting Torque or better.
approximately four revolutions from full Required
closed to fully opened. Weight
Adjusting Torque Proportional to Outlet
Maximum flow may be limited by the Pressure . . . . . . . . . 2,26 Nm @210 bar Valve . . . . . . . . . . . . . . . . 7,7 kg (17 lbs.)
addition of spacers to the throttle shaft (20 in. lbs. @ 3000 psi) Subplates
under the selector dial. FRGM03Y10 . . . . . . . . . . . . . 3,1 (7.0)
NOTE: For consistent, satisfactory,
regulation of flow, minimum pressure at FRGM03Z10 . . . . . . . . . . . . . 4,5 (10)
Number of Limit of Max. Flow
Spacers lpm (USgpm) the outlet port should be 6,2 bar (90
psi), and some fluid should always be
3 6879 (1821) passing across the integral relief valve
2 3849 (1013) to tank. The pump capacity should
therefore be slightly greater than the
1 1722,7 (4.56) maximum flow required. If 106 l/min (28
Use spacers Part No. 211026 USgpm) of regulated flow is needed, the
pump capacity should be at least 125
l/min (33 USgpm), (19 l/min (5 USgpm)
to tank). For lesser maximum flows,
reduce the 19 l/min (5 USgpm) flow to
tank in proportion to the reduction in
maximum flow.

17
Model Code

1 2 3 4 5 6

1 Special Seals 4 Adjustable Relief Valve Setting 6 Design Number


Omit if not required B 70 bar (1000 psi) Subject to change. Installation
F3 Special seals for use with C 138 bar (2000 psi) dimensions remain as shown for desig
phosphate ester type fluids F 210 bar (3000 psi) numbers 20 through 29

2 Type 5 Maximum Flow Capacity


F Flow control 28 106 lpm (28 USgpm)
R Integral pressure control
G Manifold or subplate mounting

3 Nominal Valve Size


03 3/8

18
Installation Dimensions

FRG03 Model Series


millimeter (inch)

Clearance to remove key


124 132,6
(4.88) (5.22)
85,9
101,6
Revolution Indicator (3.38)
(4.00)
11,1R 61,9 6,35
(0.44) (2.44) 84,6 (.25)
(3.33) Dia.

Inlet port P

124 6,35
(4.88) Tank port T (.25)
Dia.
50
(1.97)
.41 Dia. Thru 15 (.59) 30,2
Outlet port C Cbore 7,9 (.31) Deep (1.19)
4 places for mounting
Vent port Access hole covered 53,8
(Leave vent connection plugged when unit is locked. (2.12)
except when necessary to drop Upon turning key, lock Two keys furnished
system pressure and circulate screw is accessible.
pump delivery to the tank). Loosen to change dial
setting.
153,2
(6.03)
fully extended
47,8
(1.88)
Flow
l/min US gpm Max. Flow,
Flow vs Revolution Indicator/Dial Position
No spacer
106 28

71,3
(2.81) 63,5 91 24
(2.50)

76 20
6,35 Mounting surface
(0.25) (Seals furnished)
61 16 Max. Flow,
6,35 1 spacer
(0.25)
Outlet pressure gauge 45 12
test connection
1/2 NPT Max. Flow, 2 spacers
30 8
Two rest pins furnished.
See subplate for locations.
15 4
Max. Flow, 3 spacers

0
A B C D E
Revolution Indicator
Example: With 3 spacers, indicator will read A
and dial maximum will read between 5 and 9

19
Subplate

FRGM03Y10 Subplate 168,0


(6.62)
Installation Dimensions
103,12
millimeter (inch) Inlet connection P
10,3 (0.406) dia thru (4.06)
15,0 (0.59) c bore
0.76 0.44 R
9,6 (0.38) deep
(0.03) 7,1 (0.28) dia. 7,8 (0.31) deep
4 places for mounting 2 places for rest pins

Outlet connection C
23 (0.91) dia.
through 3/4 NPTF thd. 101,6
(from rear) 3 places 124,0 14,2 88,1
73,2 (3.47) (4.0)
(4.88) (0.56)
(2.88)

.37516 UNC2B Thd. 15,0


20,6 (0.59)
4 Places 22,4 (0.81) 6,35
(0.88) (0.25)
50,8 Tank connection T
(2.00)
77,7
(3.06) Vent connection 7,9 (0.31) dia
thru 1/4 NPTF thd from rear
101,6
(4.00)
20,6
146,1 (0.81)
(5.75)
23,9
(0.94)

FRGM03Z10

81,0
(3.19)

21,3
17,0
(0.84)
(0.67) 23,1
(0.91) dia
81,0 1 inch NPTF thd. (from rear) 3 places
(3.19)

38,1
(1.5)

NOTE:
When the subplate is not used, a machined pad, as indicated by the shaded area on the subplate, must be provided for mounting.
The pad must be flat within 0.0127mm (0.0005 inch) and smooth within 63 microinch. Mounting bolts, when provided by the customer, must
be SAE grade 7 or better.

20
Mounting Adapter Plate

FGAM03
This adapter plate and the As shown, the valve and the adapter
F(C)G03282* flow control valve can plate are mounted on subplate
be used in place of the FG06**1* FGM0610 or the equivalent customer
flow control valve where flows of the machined pad, or manifold.
existing installation do not exceed the
106 lpm (28 USgpm) flow rating of the
F(C)G0030282* size valve, or where
pressures so not exceed the rating of
the existing system.

Installation Dimensions
millimeter (inch)

FG03282* Valve

FGAM0310 Adapter plate

Subplate FGM061* or equivalent machined mounting pad


16,7 (0.656) dia
24,6 (0.969) dia cbore
15,7 (0.62) deep
4 holes 46,0
146,05 (1.81)
(5.75)
Inlet

133,6 165,1
(5.25) (6.50)

9,7 Outlet
22,4 15,7 All holes in this face correspond
(0.38) 24,5
(0.88) (0.62) to those in face of FG06**1*
R (1.12)
NOTE: As FRG03282*
177,8 models have a different porting
(7.00) arrangement, they cannot be
 All holes except 4 corner Mounting screws and O ring
adapted to the FRG06 inter-
holes on this side correspond to those in face of seals are furnished with this
face using this adapter plate.
F(C)0328* adapter plate.

21
Fluid Information

Fluid Cleanliness contacting Vickers, Incorporated. Vickers products, as any components,


Proper fluid condition is essential for Recommendations on filtration and the will operate with apparent satisfaction in
long and satisfactory life of hydraulic selection of products to control fluid fluids with higher cleanliness codes than
components and systems. Hydraulic condition are included in 561. those described. Other manufacturers
fluid must have the correct balance of will often recommend levels above
cleanliness, materials, and additives for Recommended cleanliness levels, using those specified. Experience has shown,
protection against wear of components, petroleum oil under common conditions, however, that life of any hydraulic
elevated viscosity, and inclusion of air. are based on the highest fluid pressure component is shortened in fluids with
levels in the system and are coded in higher cleanliness codes than those
Essential information on the correct the chart below. Fluids other than listed below. These codes have been
methods for treating hydraulic fluid is petroleum, severe service cycles, or proven to provide a long, trouble-free
included in Vickers publication 561 temperature extremes are cause for service life for the products shown,
Vickers Guide to Systemic adjustment of these cleanliness codes. regardless of the manufacturer.
Contamination Control available from See Vickers publication 561 for exact
your local Vickers distributor or by details.

System Pressure Level


bar (psi)
Product <70 (<1000) 70-210 (1000-3000) 210+ (3000+)
Vane Pumps Fixed 20/18/15 19/17/14 18/16/13
Vane Pumps Variable 18/16/14 17/15/13
Piston Pumps Fixed 19/17/15 18/16/14 17/15/13
Piston Pumps Variable 18/16/14 17/15/13 16/14/12
Directional Valves 20/18/15 20/18/15 19/17/14
Pressure/Flow Control Valves 19/17/14 19/17/14 19/17/14
CMX Valves 18/16/14 18/16/14 17/15/13
Servo Valves 16/14/11 16/14/11 15/13/10
Proportional Valves 17/15/12 17/15/12 15/13/11
Cylinders 20/18/15 20/18/15 20/18/15
Vane Motors 20/18/15 19/17/14 18/16/13
Axial Piston Motors 19/17/14 18/16/13 17/15/12
Radial Piston Motors 20/18/14 19/17/13 18/16/13

Fluids and Seals


Flourocarbon seals are standard and
are suitable for use with phosphate
ester type fluids or their blends, water
glycol, water-in-oil emulsion fluids and
petroleum oil.

22

You might also like