Professional Documents
Culture Documents
Hyundai's high-fashion design will add
value and beauty to any building
Observation elevators will match to all types of buildings, hotels, shopping centers,
ofce buildings, banks, hospitals and observation towers. The contemporary design of our
elevators reects the latest design trends and client preference and will add aesthetic value
and prestige to your buildings.
SQ-121A SQ-129A
Exterior Design sEXTERIOR PANELS : Painted Steel (P021) Exterior Design sEXTERIOR PANELS : Painted Steel (P016)
sDECORATIVE ILLUMINATIONS : Acrylic / LED Lighting
s(P021)
s(P016)
s / LED
Cage Design s CEILING : CD219A / Painted Steel (P022) / Skylite 10T Cage Design s CEILING : CD251A / Convective Air Sterilization System / Acrylic / Painted Steel (P022)
s WALL : STS Hairline / STS Hairline Etching (SE2302) / Transparent laminated glass (12.76T) s WALL : STS Hairline Etching (SE927) / Transparent laminated glass (12.76T)
s HANDRAIL : STS 1 Pipe s HANDRAIL : STS 1 Pipe
s FLOORING : Polyvinyl Tile s FLOORING : Polyvinyl Tile
sCD219A / (P022) / 10T sCD251A / / / (P022)
s / (SE2302) / (12.76T) s(SE927) / (12.76T)
s 1 s 1
s s
Notes Notes
1. Finished product may vary slightly from these prints. 1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials. 3. Applicable prices will vary per selected optional designs / materials.
6 Observation Elevators 7
1SIDE OBSERVATION ELEVATORS 2SIDE OBSERVATION ELEVATORS
SQ-129B RC-219A
Exterior Design sEXTERIOR PANELS : Painted Steel (P021, G804500) Exterior Design s %84%2)/2 0!.%,3 : Painted Steel (P022)
sDECORATIVE ILLUMINATIONS : Acrylic / LED Lighting s $%#/2!4)6% ),,5-).!4)/.3 : Acrylic / LED Lighting
s(P021, G804500) s(P022)
s / LED s / LED
Cage Design s CEILING : CD429B / Aluminium / Painted Steel (P023) / Acrylic / Sheet / Cage Design s CEILING : CD519D / Aluminum / Convective Air Sterilization System / Indirect Lighting
LED Lighting (Warm White) / Convective Air Sterilization System s WALL : STS Hairline / STS Hairline Etching (SE439) / Transparent laminated glass (12.76T)
s WALL : STS Hairline Etching (SE1029) / STS Mirror Trim / Transparent laminated glass (12.76T) s HANDRAIL : STS 1 Pipe
s HANDRAIL : STS 1 Pipe s FLOORING : Polyvinyl Tile
s FLOORING : Polyvinyl Tile sCD519D / / /
sCD429B / / (P023) / / / LED (Warm White) / s / (SE439) / (12.76T)
s(SE1029) / / (12.76T) s 1
s 1 s
s
Notes Notes
1. Finished product may vary slightly from these prints. 1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials. 3. Applicable prices will vary per selected optional designs / materials.
8 Observation Elevators 9
2SIDE OBSERVATION ELEVATORS 3SIDE OBSERVATION ELEVATORS
SQ-119C HG-132A
Exterior Design sEXTERIOR PANELS : Painted Steel (P011) Exterior Design sEXTERIOR PANELS : Painted Steel (P021)
sDECORATIVE ILLUMINATIONS : LED Signal Panel Decorative Lighting / Down Lighting (LED) sDECORATIVE ILLUMINATIONS : Acrylic Lens / Fluorescent illuminations through milky-white acrylic covers
s(P011) s (P021)
sLED () / (LED) s /
Cage Design s CEILING : CD219A / Painted Steel (P022) / Skylite 10T Cage Design s CEILING : CD524A / Painted Steel (P021) / Indirect Lighting / Down Lighting (LED)
s WALL : STS Dull / STS Dull Etching / Transparent laminated glass (12.76T) s WALL : STS Hairline / STS Hairline Etching / STS Mirror Trim /
s HANDRAIL : STS 1 Pipe Transparent laminated glass (10.76T) or Tempered glass (8T)
s FLOORING : Polyvinyl Tile s HANDRAIL : STS 1 Pipe
s FLOORING : Polyvinyl Tile
sCD219A / (P022) / 10T
s / / (12.76T) sCD524A / (P021) / / (LED)
s 1 s / / /
s (10.76T)(8T)
s 1
s
Notes Notes
1. Finished product may vary slightly from these prints. 1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials. 3. Applicable prices will vary per selected optional designs / materials.
10 Observation Elevators 11
3SIDE OBSERVATION ELEVATORS SEMI-CIRCLE OBSERVATION ELEVATORS
HG-339A SC-419A
Exterior Design sEXTERIOR PANELS : Painted Steel (E56305) Exterior Design sEXTERIOR PANELS : Painted Steel (P021)
sDECORATIVE ILLUMINATIONS : Acrylic / LED Lighting / Down Lighting (LED) sDECORATIVE ILLUMINATIONS : LED Lighting / Fluorescent illuminations through milky-white
acrylic covers fitted at bottom of the car
s(E56305)
s / LED / (LED) s(P021)
sLED /
Cage Design s CEILING : CD419E / Painted Steel (Dark Gray) / Sheet (CS172) / Acrylic / Down Lighting (LED) Cage Design sCEILING : CD461F / Painted Steel (White) / Fluorescent illuminations through milky-white acrylic covers
s WALL : STS Hairline / STS Hairline Etching / STS Mirror Trim / s WALL : Ti-Black Linen / LED Lighting (Lantern) / Sheet / Transparent laminated glass (10.76T) or
Transparent laminated glass (10.76T) or Tempered glass (8T) Tempered glass (8T)
s HANDRAIL : STS 1 Pipe s HANDRAIL : STS Bar Type
s FLOORING : Polyvinyl Tile s FLOORING : Granite (Po-Cheon)
sCD419E / () / (CS172) / / (LED) sCD461F / (White) /
s / / / s / LED () / / (10.76T)(8T)
(10.76T)(8T) s
s 1 s()
s
Notes Notes
1. Finished product may vary slightly from these prints. 1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials. 3. Applicable prices will vary per selected optional designs / materials.
12 Observation Elevators 13
SEMI-CIRCLE OBSERVATION ELEVATORS KEY-HOLE OBSERVATION ELEVATORS
SC-846A KC-629A
Exterior Design sEXTERIOR PANELS : Painted Steel (G614008) Exterior Design sEXTERIOR PANELS : Painted Steel (P006, P022)
sDECORATIVE ILLUMINATIONS : Fluorescent illuminations through milky-white acrylic covers sDECORATIVE ILLUMINATIONS : Decorative Lighting / Fluorescent illuminations through
fitted at top and bottom of the car milky-white acrylic covers tted at bottom of the car
s(G614008) s(P006, P022)
s s /
Cage Design sCEILING : CD523C / Painted Steel (P021, P022) / Down Lighting (LED) / Indirect Lighting (LED) Cage Design sCEILING : CD599A / Glass / Painted Steel (P021) / Down Lighting (LED) / Indirect Lighting (LED)
sWALL : STS Mirror 3S Vibration / STS Mirror / Transparent laminated glass (10.76T) or sWALL : STS 3S Vibration / STS 3S Vibration Etching / Transparent laminated glass (10.76T) or
Tempered glass (8T) Tempered glass (8T)
sHANDRAIL : STS 1 Pipe sHANDRAIL : STS 1 Pipe
sFLOORING : Visenova (Crema Marfil / Marron Emperador Dark) sFLOORING : Visenova (Rojo Alicante / Crema Marfil / Marron Emperador Dark)
sCD523C / (P021, P022) / (LED) / (LED) sCD599A / / (P021) / (LED) / (LED)
s3S / / (10.76T)(8T) s3S / 3S / (10.76T)(8T)
s 1 s 1
s( /
s( / / )
Notes Notes
1. Finished product may vary slightly from these prints. 1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials. 3. Applicable prices will vary per selected optional designs / materials.
14 Observation Elevators 15
FRAMELESS SEMI-CIRCLE OBSERVATION ELEVATORS STANDARD / OPTIONAL DESIGNS
Standard
Optional
Handrail
1R
1DW
Paint Color
Exterior Design sEXTERIOR PANELS : Painted Steel (P021)
sDECORATIVE ILLUMINATIONS : LED Lighting (Blue) / LED Acrylic Lighting / Down Lighting (LED)
s(P021)
s(LED) / (LED) / (LED)
Cage Design sCEILING : Painted Steel (P022) / Skylite 10T / LED Lighting / Down Lighting (LED) / Glass P006 2.5GY 7 / 12
P011 4.1R 4.3 / 12.8
P016 9.9YR 5.0 / 3.1
P017 6.7Y 8.7 / 2.0
Notes Note
1. Finished product may vary slightly from these prints. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials.
16 Observation Elevators 17
GLASS WALLED ELEVATORS
ND-01
Cage Design s CEILING : CD251A / Convective Air Sterilization System / Painted Steel (P022) / Acrylic
s DOOR : STS Hairline / Transparent laminated glass (10.76T) / Semitransparent Sheet
s WALL : STS Hairline / Transparent laminated glass (12.76T)
s HANDRAIL : STS 1 Pipe
s FLOORING : Polyvinyl Tile
s OPB : OPP-D241B / OPP-N241B (For the disabled), STS Hairline Plate
sCD251A / / (P022) /
s / (10.76T) /
s / (12.76T)
s 1
s
sOPP-D241B / OPP-N241B () /
Notes
1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials.
18 Observation Elevators 19
GLASS WALLED ELEVATORS
ND-02
Cage Design s CEILING : CD519D / Aluminum / Convective Air Sterilization System/ Indirect Lighting
s DOOR : STS Hairline / Transparent laminated glass (10.76T) / Semitransparent Sheet
s WALL : STS Hairline / Transparent laminated glass (12.76T)
s HANDRAIL : STS 1 Pipe
s FLOORING : Polyvinyl Tile
s INDICATOR : PI-D600
s OPB : OPP-N241B / STS Hairline Plate
sCD519D / / /
s / (10.76T) /
s / (12.76T)
s1
s
sPI-D600
sOPP-N241B /
Notes
1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials.
20 Observation Elevators 21
FRAMELESS GLASS WALLED ELEVATORS
NDFL-01
Notes
1. Finished product may vary slightly from these prints.
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.
3. Applicable prices will vary per selected optional designs / materials.
22 Observation Elevators 23
1SIDE TYPE, 2SIDE TYPE ELEVATORS Layout Plan
Gearless & Geared Elevators Layout Plan
Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & Reactions
(Unit : mm)
Clear Car M/C Room Pit Reaction (kg)
MX Speed Capacity Hoistway M/C Room Reaction (kg)
Type
Opening
X
(m/min) Internal External
A Suspension Hook
Height (MH)
(By others) Persons kg OP CA CB AB XY MX MY R1 R2 R3(Car) R4(CWT)
M/C Room
Glass Wall
(By others) Cinder
Concrete Min. 150 6 450 800 1400850 14601060 22001400 26002900 5000 2700 6650 5750
(By others)
9 600 800 14001130 14601340 22001600 26003100 5550 3100 7600 6400
R1
R2
B
Y
CB
Overhead (OH)
Machine Room
1-Side
60 11 750 800 14001350 14601560 22001850 26003350 6100 3400 8500 7000
OP Observation 90
1 105 13 900 900 16001350 16601560 24001850 30003350 6800 3750 9550 7750
20 1350 1000 18001700 19001910 28502200 35003700 9000 6650 14100 11400
24 1600 1100 20001750 21001960 30502250 37003750 9850 7050 15500 12300
Glass Enclosure
Min.
500
(By others)
Note : Machine room temperature should be maintained below 40C
9 600 800 14001130 14601340 22001600 26003100 5600 3120 7800 6600
with ventilating fan and/or air conditioner (if necessary) and
humidity below 90%.
10 700 800 14001250 14601460 22001750 26003200 5950 3350 8400 7000
Pit Depth (PP)
40C
90%
11 750 800 14001350 14601560 22001850 26003350 6100 3450 8700 7200
2-Side 60
Maintenance Deck
(By others)
Observation 90 13 900 900 16001350 16601560 24001850 30003350 6850 3750 9750 7950
2 105
R4 R3
15 1000 900 16001500 16601710 24002000 30003500 7150 3930 10350 8350
Receptacle Ladder Waterproof Finish
(By others) (By others) (By others)
17 1150 1000 18001500 19001710 28502000 35003500 9000 5400 13000 10700
20 1350 1000 18001700 19001910 28502200 35003700 9100 6700 14250 11600
24 1600 1100 20001750 21001960 30502250 37003750 9950 7100 15700 12500
Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors. Consult Hyundai.
2. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
MX 3. The capacity in persons is calculated at 65kg / person. (EN81=75kg / person)
X 4. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied,
A hoistway size for 1 car should be applied above X1 dimension plus 100mm.
Glass Wall 1.
(By others) 2. CA1600mm
CB1350mm
3. 1100mm
1(X) X + 100mm
Vent Grille (By others)
B
R1
R2
Y
CB
CA
(Unit : mm)
Vent Fan (By others)
Machine Room
Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH)
MY
OP
60 4700 1750 2200
90 4900 1800 2400
Control
Panel 105 5000 2100 2400
Distribution Board
(By others) Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction machine
with double isolation pad.
3. For gearless (1:1 roping) elevators, the minimum machine room height should be 2400mm.
1.
2. 2800mm
3. 1:1
2400mm
24 Observation Elevators 25
3SIDE TYPE ELEVATORS Layout Plan SEMICIRCLE TYPE ELEVATORS Layout Plan
Gearless & Geared Elevators Layout Plan Gearless & Geared Elevators Layout Plan
Plan of Hoistway & Machine Room Section of Hoistway Plan of Hoistway & Machine Room Section of Hoistway
X2, MX2 Suspension Hook X2, MX2 Suspension Hook
(By others) (By others)
550 A 200 A 550
550 A 200 A 550
Glass Enclosure
(By others)
Height (MH)
Height (MH)
M/C Room
M/C Room
Cinder Glass Enclosure (By others) Cinder
Concrete Min.150
Concrete Min. 150
(By others)
(By others)
R2
CB
Y
B
CB
Y
B
CA
R2
R1
R1
CA
S
R1
R1
Overhead (OH)
Overhead (OH)
MY
OP OP
OP OP
Ent. Height(EH)
2100
2100
Control Control
Vent Fan (By others)
Control Control
Vent Fan (By others)
Travel (TR)
Travel (TR)
Concrete (Min. 3600) or
Glass Enclosure
Glass Enclosure
Machine Room Access Door (By others) Machine Room Access Door (By others) 500
500
Min. 900 (W)2100 (H) Min. 900 (W)2100 (H)
(By others)
(By others)
(Unit : mm) (Unit : mm)
Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH) Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH)
Pit Depth (PP)
Clear Car Hoistway M/C Room M/C Room Pit Clear Car Hoistway M/C Room M/C Room Pit
Capacity Reaction (kg) Capacity Reaction (kg) Reaction (kg)
Speed
Opening Internal External 1Car 2Cars Depth 1Car 2Cars Depth Reaction (kg) Speed
Opening Internal External 1Car 2Cars Depth 1Car 2Cars Depth
(m/min) (m/min)
Persons kg OP CA CB AB X1 X2 Y S MX1 MX2 MY R1 R2 R2 R3 R4 Persons kg OP CA CB AB X1 X2 Y S MX1 MX2 MY R1 R2 R2 R3 R4
11 750 800 14001400 14601610 2450 5100 2000 1200 2900 5100 3500 6150 3450 6900 8700 7150 11 750 800 14001480 14601690 2450 5100 2000 1200 2900 5100 3500 6180 3450 6900 8700 7150
13 900 900 16001450 16601660 2650 5500 2050 1350 3300 5500 3550 6900 3750 7500 9700 7900 13 900 900 16001500 16601710 2650 5500 2050 1350 3300 5500 3550 6930 3750 7500 9700 7900
60 60
15 1000 900 16001570 16601780 2650 5500 2200 1350 3300 5500 3700 7200 3950 7900 10300 8300 15 1000 900 16001650 16601860 2650 5500 2200 1350 3300 5500 3700 7220 3950 7900 10300 8300
90 90
17 1150 1000 18001580 19001790 2850 6100 2200 1600 3500 6100 3700 9100 5450 10900 13150 10900 17 1150 1000 18001650 19001860 2850 6100 2200 1600 3500 6100 3700 9100 5450 10900 13150 10900
105 105
20 1350 1000 18001800 19002010 2850 6100 2400 1600 3500 6100 3900 9150 6750 13500 14550 11850 20 1350 1000 18001900 19002110 2850 6100 2400 1600 3500 6100 3900 9150 6750 13500 14550 11850
24 1600 1100 18002000 19002210 2850 6100 2600 1600 3500 6100 4100 10000 7150 14300 16100 12900 24 1600 1100 18002130 19002340 2850 6100 2600 1600 3500 6100 4100 10050 7190 14380 16100 12900
Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai. Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
2. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied 2. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied
above X1 dimension plus 100mm. above X1 dimension plus 100mm.
3. Consult Hyundai if the capacity is 10 persons and less. 3. Consult Hyundai if the capacity is 10 persons and less.
1. 1.
2. CA1600mm
CB1350mm 2. CA1600mm
CB1350mm
3. 1100mm1 X
X 100mm 3. 1100mm1 X
X 100mm
4. 11 4. 11
26 Observation Elevators 27
MRL ELEVATORS Layout Plan
Machine-Room-Less Elevators Layout Plan
Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & Reactions (Unit : mm)
Capacity Clear Car Hoistway M/C Room Reaction (kg) pit Reaction (kg)
Type Speed
Opening
X Lighting (By others) (m/min) Internal External
A
Hook (By others)
Persons kg OP CA CB AB XY R1 R2 R3 R4 R5 R6
R3 R1
8 550 800 13001090 13601300 21001700 4100 1950 700 1800 7500 6400
CA 9 600 800 13001160 13601370 21001800 4250 1980 750 1830 7800 6600
Top floor
(By others) 10 700 800 13001300 13601510 21001850 4500 2050 800 1900 8400 7000
Traction
CB
Machine 11 750 800 13001400 13601610 21001900 4650 2080 900 1950 8700 7200
Y
1-Side 60
Observation 900 15001400 15601610 23001900
90 13 900 5050 2250 1000 2100 9750 7950
1 930 (HC) 16001350 16601560 24001850
105
15 1000 900 16001400 17601610 24001950 5750 2400 1100 2500 10550 8550
17 1150 1000 18001400 19601610 27002150 6650 3500 1150 3150 13200 10900
Lighting (By others) 20 1350 1000 18001600 19601810 27002450 7730 4850 1400 3500 14450 11800
R4 R2
24 1600 1100 20001700 21601910 29002500 8250 5000 1500 3650 15900
Travel (TR)
OP 12700
Notes : 1. When non-standard capacities and dimensions (including fire protection doors) are required to meet the local code, please consult Hyundai.
Receptacle 2. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances should be made considering the sloping of the hoistways.
(By others) 3. The capacity in persons is calculated at 65kg / person. (EN81=75kg / person)
4. If the height of floor is over 11m, please consult Hyundai as to the needs for emergency exit.
Ladder 5. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied
(By others) above X1 dimension plus 100mm.
6. In case the emergency stop switch is applied to the counter weight, consult Hyundai.
7. If the car is heavier than 1000kg because of interior decoration in case of elevator for 15 persons (1000kg), consult Hyundai.
Lighting 1.
6.
105 5000 2100 630
28 Observation Elevators 29
FRAMELESS GLASS WALLED ELEVATORS Layout Plan
Gearless & Geared / MRL Elevators Layout Plan
Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & ReactionsGearless & Geared Elevators (Unit : mm)
Clear Car M/C Room Pit
Speed Capacity Hoistway M/C Room Reaction (kg) Reaction (kg)
Type
Opening
Lighting (By others) (m/min) Internal External
Hook (By others)
Persons kg OP CA CB AB XY MX MY R1 R2 R5 R6
8 550 800 14001030 15601240 23001500 27003000 5450 3035 7800 6700
Gearless & Geared
MX 9 600 800 14001130 15601340 23001600 27003100 5640 3150 8200 7000
Traction 10 700 800 14001250 15601460 23001750 27003200 6010 3370 8750 7350
X
Machine 45
Frameless 11 750 800 14001350 15601560 23001850 27003350 6180 3480 9300 7800
A
Glass walled 60
13 900 900 16001350 17601560 25001850 31003350 6930 3795 10350 8550
90
15 1000 900 16001500 17601710 25002000 31003500 7220 3970 11050 9050
CA 20 1350 1000 18001700 19601910 28902200 36003700 9144 6760 15300 12600
24 1600 1100 20001750 21601960 30902250 38003750 10020 7190 16800 13600
R1
R2
CB
Notes : 1. The machine room reactions are changeable according to the size of hoistway and
Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH) center of car weight.
MY
2. The same dimension of passenger elevators apply to the others except the above.
Machine Room
45 4500 1500 2200 3. For NDFL-01 type, consult Hyundai Elevator since hoistway dimension and machine
room reactions for NDFL-01 type are changeable under different conditions.
Travel (TR)
Standard Dimensions & ReactionsMRL Elevators (Machine-Room-Less) (Unit : mm)
Receptacle
(By others) Capacity Clear Car Hoistway M/C Room Reaction (kg) Pit
Type Speed
Opening
Reaction (kg)
Ladder
(m/min) Internal External
(By others)
Persons kg OP CA CB AB XY R1 R2 R3 R4 R5 R6
8 550 800 13001100 14601310 21301750 4295 1870 660 1960 8150 7050
Gallery Window Lighting Lighting 9 600 800 13001190 14601400 21301800 4515 1910 740 2010 8500 7300
Pit Depth (PP)
Speed (m/min) Persons Overhead (OH) Pit (PP) Speed (m/min) Persons Overhead (OH) Pit (PP)
CB
Control
Panel
OP CP Max.15 4200 1500 45 4850
R4 R2
(*) 45, 60 1600
17 4200 1600 60 4850
OP 20, 24
90 4300 1800 90 5000 1800
Max.17
105 4400 2000 105 5000 2100
Note : The lighting of hoistway should be installed less than Notes : 1. The machine room reactions are changeable according to the size of hoistway and center of car weight.
500mm from above the ceiling of hoistway and within 2. The same dimension of passenger elevators apply to the others except the above.
500mm above the bottom of the pit. (By others) 3. For NDFL-01 type, consult Hyundai Elevator since hoistway dimension and machine room reactions for NDFL-01 type are changeable under different conditions.
500mm 1.
500mm
2.
3. NDFL-01
30 Observation Elevators 31
WORKS TO BE DONE BY OTHER CONTRACTORS SPECIAL NOTES ON PLANNING THE INSTALLATION
The following works are not included in the elevator contract, and shall be done by other contractors In planning the installation of observation elevators, the architect as well as the product designer should
in accordance with the Hyundai Elevator's drawings and the applicable codes and regulations. consider the unique design features and special requirements of observation elevators. These special
The reference rules shown are from Code ANSI. notes should be carefully considered for both building construction and product engineering.
Building Work 14. Hoisting beams, trap doors, and other means of access to machine room
for maintenance and equipment removal purposes. (Rule 101.3d)
Observation Glass at Car & Hoistway Air-Conditioning & Ventilation
Hoistway 15. Cable guards in the machine room or secondary level. (Rule 104.1) Glass Window on Car The in-car temperature of the observation elevator can be highly increased
1. Clear, plumb hoistway with re resistant hatch walls as required by the The glass used for the car windows shall be 8mm thick tempered glass. Each because of the solar radiation heat, this factor should be considered in
applicable code. (Rule 100.1a) 16. Supports for machine and sheave beams and reactions including wall glass window shall not be over 1,250mm wide and 1,800mm high. planning the hoistway layout.
pockets and patching after beams are set in place. (Rule 105.1 to 105.5)
2. 75 bevel guards on all projections, recesses, or setbacks over 50mm For the passengers safety, the glass window shall be 500mm above car oor When required by the building, the air-conditioner can be installed on the
except on side used for loading or unloading. (Rule 100.6) unless it is especially required. observation elevator. When the air-conditioner is installed, a water drain is
required in the pit.
3. Venting of the hoistway as required by the applicable code or responsible For the passengers safety, the handrail shall be installed along the glass
authority. (Rule 100.4) Electrical Work window. The hoistway and the machine room should be properly ventilated to
prevent excessive temperature rise.
4. Supports for rail brackets at each oor, roof, and machine room. (Rule 200.9) Hoistway
Maximum allowable vertical spacing of rail supports without backing.
1. Light outlet for each elevator, in center of hoistway (or in machine room)
Glass Wall at Hoistway
(Rule 200.4 and 301.1) Divider beams 100mm between hoistway at each The glass used for the hoistway wall shall be safety-wired glass or
as indicated by Hyundai Elevator Company.
oor and roof, for guide rail bracket supports. (Rule 200.4, 200.9 and 301.1) tempered glass
2. Convenience outlet and light xture in pit with switch located adjacent to Hoistway Structures & Others
5. Recesses supports and patching as required to accommodate hall button To prevent excessive temperature rise in the hoistway, the hoistway glass
the access door. (Rule 106.1e)
boxes, signal xtures, etc. shall be radiant-heat absorbent glass. To facilitate the inspection, maintenance and cleaning of the car exteriors,
3. Wiring and piping work of emergency bell, interphone, etc. outside the an access hole and min. 500mm wide maintenance deck with a glass or
6. All barricades either outside elevator hoistways or between inside hoist- To enable the cleaning of the hoistway glass, the distance between the car concrete enclosure should be provided at the bottom of the hoistway (usu-
hoistway and the machine room.
ways as required. exterior and the glass wall shall be within the range of 200~300mm. ally at the basement level).
7. Dry pit reinforced to sustain normal vertical forces from rails and buffers. The glass wall shall be designed to prevent rain, moisture or dusts from To prevent the breakage of the hoistway glass from the outside, 1.8 meters
(Rule 106.1b and 109) Consult Hyundai Elevator Company for rail forces Machine Room entering the hoistway. high concrete enclosure shall be provided at ground level.
and buffer impacts. Where there is space below the pit oor that can be 4. Lighting, convenience outlets, ventilation, heating of machine room, and
occupied, consult Hyundai Elevator Company for special requirements. machinery space. (Rule 101.5) When the hoistway glass is directly exposed to the public, a fence should
(Rule 300.4) Cylinder hole, casings under the pit as required, and backlling be installed at min. 1.5 meters distance from the hoistway to prevent
around the cylinder casings when direct plunger type is to be installed. 5. Temperature should be maintained below 40C by a ventilating fan and /
access.
or air conditioner, if necessary, and humidity below 90%. Exterior Lighting
8. Where access to the pit is by means of the lowest hoistway entrance, When any especially-designed car top & bottom is required, the pit depth
vertical iron ladder extending 1060mm minimum above sill of access door. 6. A fused disconnect switch or circuit breaker for each elevator and light
The lamps used for the exterior illumination shall be designed for long life and overhead requirement may change.
(Rule 106.1d) switch located per the applicable code and where practicable located
and easy replacement.
adjacent to the door of the machine room. (Rule 210.5 and 306.7) When an outdoor type observation elevator is required for application in an
9. Entrance walls and nished oor are not to be constructed until after door The electric power requirements may vary per elevator models and illumi- outside openhoistway, special engineering is required for protection from
frames and sills are in place. Door frames are to be anchored to walls and 7. Feeder and branch wiring to the controller, including main-line switch
nation designs, however the proper power source required is AC 1, 220V, water, corrosion, ice, wind, dusts, etc.
properly grouted in place to maintain legal re rating. and convenience outlets.
20-30A range.
10. For application as indoor or outdoor observation elevator, a glass enclosure 8. Suitable power feeder and branch wiring circuits as required for
of at least 3.6m in height at the bottom landing is recommended for safety. elevators with power-operated doors, including disconnect switch or
circuit breaker.
For use as an outdoor observation elevator, a full-height glass enclosure is Heat Emission of Machine Room
required.
Emergency Provisions Q : (kcal/H)=W x V x F x N
W : Capacity (kg) N : Number of cars
Machine Room 9. Elevator remans and other emergency services wiring and interconnec-
V : Speed (m/min) F : Factor (1/40 - VVVF)
tions to automatic sprinkler systems or heat and smoke sensing devices
11. Enclosed and protected machine room. (Rule 101.1) furnished by others and installed to terminal points on the elevator
12. Access to the machine room and machinery space as required by the ap- controllers.
plicable code or responsible authority. (Rule 101.3) 10. When emergency power operation of elevators is required, the electrical
13. Reinforced concrete machine room oor slab or grating, as specied, which contractor should coordinate with Hyundai Elevator Company or local
distributor for operation requirements.
Data Required for Elevator Estimation
must not be placed over the hoistway until elevator machinery is set in
position. (Rule 100.3 for Traction Elevator) 11. Elevator remans and other emergency service requirements may differ
Clear access above ceiling or trench in oor, for oil line and wiring duct from each country. Consult Hyundai Elevator Company or local distributor Project Name and Location Machine Location (Overhead or Basement)
from machine room, if machine room is remote from elevator hoistway. (For for other local requirements.
Hydraulic Elevator) Applicable Code (ANSI, BS, JIS, CEN, etc.) Travel, Overhead & Pit Depth
Cutout through machine room wall, for oil line and wiring duct as required 12. When provisions for earthquake protection are required, consult Hyundai Required Delivery Hoistway width, Depth and Elevation
by Hyundai Elevators shop drawings. (For Hydraulic Elevator) Elevator Company for special requirements. Type & Units in System Door Width & Height
Capacity Car & Entrance Design
Speed Signal Fixtures
Control / Operation System Special Features Required
Landings & Openings (Front & Rear) Power Supply
32 Observation Elevators 33
WORKS TO BE DONE BY OTHER CONTRACTORS SPECIAL NOTES ON PLANNING THE INSTALLATION
13 90 15 40 60 12 21 10 16 6 10 50
(900) 105 15 40 75 14 24 10 25 6 10 195
120 18.5 50 100 15 28 16 35 6 10 3
34 Observation Elevators 35
INTERNATIONAL SALES & SERVICE NETWORK
KAZAKHSTAN
AZERBAIJAN
ITALY MONGOLIA
TURKMENISTAN
KOREA
SEOUL
TURKEY SYRIA CHINA
TUNISIA
ICHEON JAPAN
LIBYA JORDAN IRAQ IRAN
ALGERIA BANGLADESH
EGYPT KUWAIT MEXICO
MOROCCO BAHRAIN QATAR PAKISTAN
U.A.E. MYANMAR
INDIA GUATEMALA
VIETNAM CUBA
SAUDI ARABIA OMAN PHILIPPINES
THAILAND PANAMA VENEZUELA
SUDAN COLOMBIA
ECUADOR
KENYA PERU
INDONESIA
BOLIVIA
36 Observation Elevators 37