Observation Elevators

Moving solutions with safety, reliability and efficiency


OBSERVATION ELEVATORS - We reserve the right to change designs and specifications for the product development without prior notice. Copyright HYUNDAI ELEVATOR CO., LTD. All rights reserved. Printed in Korea.
Catalog code : C-OBE-E1615 / 2012. 3 / Revision 16
Space where you want to stay longer -


The harmony of advanced technology, unique


design and sophisticated atmosphere...

Hyundai observation elevator enriches the


moving experience with spectacular views
and a comfortable atmosphere. The value of a
building will be increased with the inclusion of
a space that bids people to linger around.

With diverse options for an observation window with one,


two, three sides or semicircular or a key hole type window,
Hyundai Elevator brings higher satisfaction to its clients.
A hoistway can be installed outside of a building, thus bypassing
the need to occupy space within the building.
Thanks to Hyundai's propriety core technology, its elevators give a
more comfortable and smooth ride to passengers.

 


 












Hyundai's high-fashion design will add
value and beauty to any building


Observation elevators will match to all types of buildings, hotels, shopping centers,
ofce buildings, banks, hospitals and observation towers. The contemporary design of our
elevators reects the latest design trends and client preference and will add aesthetic value
and prestige to your buildings.

       01 Lotte Department Store


 02 Sam-il Bridge 02 03
03 Beauty Shop
01
04 Hyundai Department Store
05 The Asan Institute for Policy Studies 04 05 06
06 Hyundai Asan Tower
1SIDE OBSERVATION ELEVATORS  1SIDE OBSERVATION ELEVATORS 

SQ-121A SQ-129A

Exterior Design sEXTERIOR PANELS : Painted Steel (P021) Exterior Design sEXTERIOR PANELS : Painted Steel (P016)
sDECORATIVE ILLUMINATIONS : Acrylic / LED Lighting
s(P021)
s(P016)
s / LED

Cage Design s CEILING : CD219A / Painted Steel (P022) / Skylite 10T Cage Design s CEILING : CD251A / Convective Air Sterilization System / Acrylic / Painted Steel (P022)
s WALL : STS Hairline / STS Hairline Etching (SE2302) / Transparent laminated glass (12.76T) s WALL : STS Hairline Etching (SE927) / Transparent laminated glass (12.76T)
s HANDRAIL : STS 1 Pipe s HANDRAIL : STS 1 Pipe
s FLOORING : Polyvinyl Tile s FLOORING : Polyvinyl Tile
sCD219A / (P022) / 10T sCD251A /  / / (P022)
s / (SE2302) / (12.76T) s(SE927) / (12.76T)
s 1 s 1
s s

Notes Notes
1. Finished product may vary slightly from these prints.  1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.  2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials.  3. Applicable prices will vary per selected optional designs / materials. 

6 Observation Elevators 7
1SIDE OBSERVATION ELEVATORS  2SIDE OBSERVATION ELEVATORS 

SQ-129B RC-219A

Exterior Design sEXTERIOR PANELS : Painted Steel (P021, G804500) Exterior Design s%84%2)/20!.%,3 : Painted Steel (P022)
sDECORATIVE ILLUMINATIONS : Acrylic / LED Lighting s$%#/2!4)6%),,5-).!4)/.3 : Acrylic / LED Lighting
s(P021, G804500) s(P022)
s / LED s / LED

Cage Design s CEILING : CD429B / Aluminium / Painted Steel (P023) / Acrylic / Sheet / Cage Design s CEILING : CD519D / Aluminum / Convective Air Sterilization System / Indirect Lighting
LED Lighting (Warm White) / Convective Air Sterilization System s WALL : STS Hairline / STS Hairline Etching (SE439) / Transparent laminated glass (12.76T)
s WALL : STS Hairline Etching (SE1029) / STS Mirror Trim / Transparent laminated glass (12.76T) s HANDRAIL : STS 1 Pipe
s HANDRAIL : STS 1 Pipe s FLOORING : Polyvinyl Tile
s FLOORING : Polyvinyl Tile sCD519D / /  /
sCD429B / / (P023) / / / LED (Warm White) /  s / (SE439) / (12.76T)
s(SE1029) /  / (12.76T) s 1
s 1 s
s

Notes Notes
1. Finished product may vary slightly from these prints.  1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.  2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials.  3. Applicable prices will vary per selected optional designs / materials. 

8 Observation Elevators 9
2SIDE OBSERVATION ELEVATORS  3SIDE OBSERVATION ELEVATORS 

SQ-119C HG-132A

Exterior Design sEXTERIOR PANELS : Painted Steel (P011) Exterior Design sEXTERIOR PANELS : Painted Steel (P021)
sDECORATIVE ILLUMINATIONS : LED Signal Panel Decorative Lighting / Down Lighting (LED) sDECORATIVE ILLUMINATIONS : Acrylic Lens / Fluorescent illuminations through milky-white acrylic covers
s(P011) s(P021)
sLED () / (LED) s /

Cage Design s CEILING : CD219A / Painted Steel (P022) / Skylite 10T Cage Design s CEILING : CD524A / Painted Steel (P021) / Indirect Lighting / Down Lighting (LED)
s WALL : STS Dull / STS Dull Etching / Transparent laminated glass (12.76T) s WALL : STS Hairline / STS Hairline Etching / STS Mirror Trim /
s HANDRAIL : STS 1 Pipe Transparent laminated glass (10.76T) or Tempered glass (8T)
s FLOORING : Polyvinyl Tile s HANDRAIL : STS 1 Pipe
s FLOORING : Polyvinyl Tile
sCD219A / (P022) / 10T
s /  / (12.76T) sCD524A / (P021) / / (LED)
s 1 s /  /  /
s (10.76T)(8T)
s 1
s

Notes Notes
1. Finished product may vary slightly from these prints.  1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.  2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials.  3. Applicable prices will vary per selected optional designs / materials. 

10 Observation Elevators 11
3SIDE OBSERVATION ELEVATORS  SEMI-CIRCLE OBSERVATION ELEVATORS 

HG-339A SC-419A

Exterior Design sEXTERIOR PANELS : Painted Steel (E56305) Exterior Design sEXTERIOR PANELS : Painted Steel (P021)
sDECORATIVE ILLUMINATIONS : Acrylic / LED Lighting / Down Lighting (LED) sDECORATIVE ILLUMINATIONS : LED Lighting / Fluorescent illuminations through milky-white
acrylic covers fitted at bottom of the car
s(E56305)
s / LED / (LED) s(P021)
sLED / 

Cage Design s CEILING : CD419E / Painted Steel (Dark Gray) / Sheet (CS172) / Acrylic / Down Lighting (LED) Cage Design sCEILING : CD461F / Painted Steel (White) / Fluorescent illuminations through milky-white acrylic covers
s WALL : STS Hairline / STS Hairline Etching / STS Mirror Trim / s WALL : Ti-Black Linen / LED Lighting (Lantern) / Sheet / Transparent laminated glass (10.76T) or
Transparent laminated glass (10.76T) or Tempered glass (8T) Tempered glass (8T)
s HANDRAIL : STS 1 Pipe s HANDRAIL : STS Bar Type
s FLOORING : Polyvinyl Tile s FLOORING : Granite (Po-Cheon)
sCD419E / () / (CS172) / / (LED) sCD461F / (White) / 
s /  /  / s / LED () / / (10.76T)(8T)
(10.76T)(8T) s

s 1 s()
s

Notes Notes
1. Finished product may vary slightly from these prints.  1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.  2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials.  3. Applicable prices will vary per selected optional designs / materials. 

12 Observation Elevators 13
SEMI-CIRCLE OBSERVATION ELEVATORS  KEY-HOLE OBSERVATION ELEVATORS 

SC-846A KC-629A

Exterior Design sEXTERIOR PANELS : Painted Steel (G614008)  Exterior Design sEXTERIOR PANELS : Painted Steel (P006, P022) 
sDECORATIVE ILLUMINATIONS : Fluorescent illuminations through milky-white acrylic covers sDECORATIVE ILLUMINATIONS : Decorative Lighting / Fluorescent illuminations through
fitted at top and bottom of the car milky-white acrylic covers tted at bottom of the car
s(G614008) s(P006, P022)
s s / 

Cage Design sCEILING : CD523C / Painted Steel (P021, P022) / Down Lighting (LED) / Indirect Lighting (LED) Cage Design sCEILING : CD599A / Glass / Painted Steel (P021) / Down Lighting (LED) / Indirect Lighting (LED)
sWALL : STS Mirror 3S Vibration / STS Mirror / Transparent laminated glass (10.76T) or sWALL : STS 3S Vibration / STS 3S Vibration Etching / Transparent laminated glass (10.76T) or
Tempered glass (8T) Tempered glass (8T)
sHANDRAIL : STS 1 Pipe sHANDRAIL : STS 1 Pipe
sFLOORING : Visenova (Crema Marfil / Marron Emperador Dark) sFLOORING : Visenova (Rojo Alicante / Crema Marfil / Marron Emperador Dark)
sCD523C / (P021, P022) / (LED) / (LED) sCD599A / / (P021) / (LED) / (LED)
s3S /  / (10.76T)(8T) s3S / 3S  / (10.76T)(8T)
s 1 s 1
s( / 
 s( / / )

Notes Notes
1. Finished product may vary slightly from these prints.  1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size.  2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials.  3. Applicable prices will vary per selected optional designs / materials. 

14 Observation Elevators 15
FRAMELESS SEMI-CIRCLE OBSERVATION ELEVATORS  STANDARD / OPTIONAL DESIGNS 

SC-419B Glass Size

Standard
Optional

Handrail

1C  


1DV  

1R 
1DW  

Paint Color 
Exterior Design sEXTERIOR PANELS : Painted Steel (P021)
sDECORATIVE ILLUMINATIONS : LED Lighting (Blue) / LED Acrylic Lighting / Down Lighting (LED)
s(P021)
s(LED) / (LED) / (LED)

Cage Design sCEILING : Painted Steel (P022) / Skylite 10T / LED Lighting / Down Lighting (LED) / Glass P006 2.5GY 7 / 12
P011 4.1R 4.3 / 12.8
P016 9.9YR 5.0 / 3.1
P017 6.7Y 8.7 / 2.0

sWALL : STS Bead Blast, STS Mirror Trim / Glass


sHANDRAIL : STS 1 Pipe
sFLOORING : Marble (Star Galaxy)
s(P022) / 10T / LED / (LED) /
s /  /
s 1
s() P019 5.1Y 7.6 / 1.1
P020 
P021 
P022 

Notes Note
1. Finished product may vary slightly from these prints.  Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials. 

16 Observation Elevators 17
GLASS WALLED ELEVATORS 

ND-01

Front View Rear View

Cage Design sCEILING : CD251A / Convective Air Sterilization System / Painted Steel (P022) / Acrylic
sDOOR : STS Hairline / Transparent laminated glass (10.76T) / Semitransparent Sheet
sWALL : STS Hairline / Transparent laminated glass (12.76T)
sHANDRAIL : STS 1 Pipe
sFLOORING : Polyvinyl Tile
sOPB : OPP-D241B / OPP-N241B (For the disabled), STS Hairline Plate
sCD251A /  / (P022) / 
s / (10.76T) / 
s / (12.76T)
s 1
s
sOPP-D241B / OPP-N241B () / 

Notes
1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials. 

18 Observation Elevators 19
GLASS WALLED ELEVATORS 

ND-02

Front View Rear View

Cage Design sCEILING : CD519D / Aluminum / Convective Air Sterilization System/ Indirect Lighting
sDOOR : STS Hairline / Transparent laminated glass (10.76T) / Semitransparent Sheet
sWALL : STS Hairline / Transparent laminated glass (12.76T)
sHANDRAIL : STS 1 Pipe
sFLOORING : Polyvinyl Tile
sINDICATOR : PI-D600
sOPB : OPP-N241B / STS Hairline Plate
sCD519D / /  /
s / (10.76T) / 
s / (12.76T)
s1
s
sPI-D600
sOPP-N241B / 

Notes
1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials. 

20 Observation Elevators 21
FRAMELESS GLASS WALLED ELEVATORS 

NDFL-01

Front View Rear View

Cage Design sCEILING : STS Hairline / Down Lighting (LED)


sDOOR : STS Hairline / Transparent laminated glass (over 16T) / Semitransparent Sheet
sWALL : STS Hairline / Transparent laminated glass (over 16T)
sHANDRAIL : STS 1 Pipe
sFLOORING : Marble
sINDICATOR : PI-D110
sOPB : OPP-N270A / STS Hairline
s /  LED

s / (16T

s / (16T )
s 1
s
sPI-D110
sOPP-N270A / 

Notes
1. Finished product may vary slightly from these prints. 
2. Number and / or size of ceiling panels and number of lighting fixtures will vary per selected car size. 
3. Applicable prices will vary per selected optional designs / materials. 

22 Observation Elevators 23
1SIDE TYPE, 2SIDE TYPE ELEVATORS Layout Plan  
Gearless & Geared Elevators Layout Plan

Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & Reactions
(Unit : mm)
Clear Car M/C Room Pit Reaction (kg)
MX Speed Capacity Hoistway M/C Room Reaction (kg)
Type 
Opening   
X

(m/min)  Internal External 
A Suspension Hook

Height (MH)
(By others) Persons kg OP CA CB AB XY MX MY R1 R2 R3(Car) R4(CWT)

M/C Room
Glass Wall
(By others) Cinder
Concrete Min. 150 6 450 800 1400850 14601060 22001400 26002900 5000 2700 6650 5750
(By others)

Vent Grille(By others)


8 550 800 14001030 14601240 22001500 26003000 5350 3000 7300 6200

9 600 800 14001130 14601340 22001600 26003100 5550 3100 7600 6400
R1

R2
B
Y

CB

Min. 900 (W)2100 (H)


Access Door (By others)
CA
10 700 800 14001250 14601460 22001750 26003200 5900 3300 8200 6800
Vent Fan (By others)

Overhead (OH)
Machine Room
1-Side

Glass Enclosure (By others)


MY

60 11 750 800 14001350 14601560 22001850 26003350 6100 3400 8500 7000
OP Observation 90
1 105 13 900 900 16001350 16601560 24001850 30003350 6800 3750 9550 7750

Ent. Height (EH)


2100
Control 15 1000 900 16001500 16601710 24002000 30003500 7100 3900 10100 8150
Panel
Distribution Board
17 1150 1000 18001500 19001710 28502000 35003500 8900 5300 12800 10500

Total Height (TH)


(By others)

20 1350 1000 18001700 19001910 28502200 35003700 9000 6650 14100 11400

24 1600 1100 20001750 21001960 30502250 37003750 9850 7050 15500 12300

Concrete (Min. 3600) or


Travel (TR) 8 550 800 14001030 14601240 22001500 26003000 5400 3050 7500 6400

Glass Enclosure
Min.
500

(By others)
Note : Machine room temperature should be maintained below 40C
9 600 800 14001130 14601340 22001600 26003100 5600 3120 7800 6600
with ventilating fan and/or air conditioner (if necessary) and
humidity below 90%.
10 700 800 14001250 14601460 22001750 26003200 5950 3350 8400 7000
Pit Depth (PP)

40C 90%  11 750 800 14001350 14601560 22001850 26003350 6100 3450 8700 7200
  2-Side 60
 Maintenance Deck
(By others)
Observation 90 13 900 900 16001350 16601560 24001850 30003350 6850 3750 9750 7950
2 105
R4 R3
15 1000 900 16001500 16601710 24002000 30003500 7150 3930 10350 8350
Receptacle Ladder Waterproof Finish
(By others) (By others) (By others)
17 1150 1000 18001500 19001710 28502000 35003500 9000 5400 13000 10700

20 1350 1000 18001700 19001910 28502200 35003700 9100 6700 14250 11600

24 1600 1100 20001750 21001960 30502250 37003750 9950 7100 15700 12500

Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors. Consult Hyundai.
2. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
MX 3. The capacity in persons is calculated at 65kg / person. (EN81=75kg / person)
X 4. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied,
A hoistway size for 1 car should be applied above X1 dimension plus 100mm.
Glass Wall 1. 
(By others) 2. CA1600mm CB1350mm 
3. 1100mm 1(X) X + 100mm
Vent Grille (By others)
B

R1

R2
Y

CB

Min. 900 (W)2100 (H)


Access Door (By others)

CA
(Unit : mm)
Vent Fan (By others)

Machine Room

Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH)
MY


OP
60 4700 1750 2200
90 4900 1800 2400
Control
Panel 105 5000 2100 2400
Distribution Board
(By others) Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction machine
with double isolation pad.
3. For gearless (1:1 roping) elevators, the minimum machine room height should be 2400mm.
1. 
2.  2800mm
3. 1:1
 2400mm

24 Observation Elevators 25
3SIDE TYPE ELEVATORS Layout Plan  SEMICIRCLE TYPE ELEVATORS Layout Plan 
Gearless & Geared Elevators Layout Plan Gearless & Geared Elevators Layout Plan

Plan of Hoistway & Machine Room Section of Hoistway Plan of Hoistway & Machine Room Section of Hoistway
X2, MX2 Suspension Hook X2, MX2 Suspension Hook
(By others) (By others)
550 A 200 A 550
550 A 200 A 550
Glass Enclosure
(By others)

Height (MH)
Height (MH)

M/C Room
M/C Room
Cinder Glass Enclosure (By others) Cinder
Concrete Min.150
Concrete Min. 150
(By others)
(By others)
R2

Vent Grille (By others)


Vent Grille (By others)

CB

Y
B

CB

Y
B
CA

R2
R1
R1

CA

S
R1

R1

Overhead (OH)
Overhead (OH)

Glass Enclosure (By others)

Vent Grille (By others)

Glass Enclosure (By others)


Vent Grille (By others)
MY

MY
OP OP
OP OP

Ent. Height (EH)

Ent. Height(EH)
2100

2100
Control Control
Vent Fan (By others)

Control Control
Vent Fan (By others)

Vent Fan (By others)


Panel Panel Panel Panel

Total Height (TH)

Total Height (TH)


Vent Fan (By others)
Distribution Board Distribution Board
(By others) (By others)

Travel (TR)

Travel (TR)
Concrete (Min. 3600) or

Concrete (Min. 3600) or


Min. Min.

Glass Enclosure

Glass Enclosure
Machine Room Access Door (By others) Machine Room Access Door (By others) 500
500
Min. 900 (W)2100 (H) Min. 900 (W)2100 (H)

(By others)

(By others)
(Unit : mm) (Unit : mm)

Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH) Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH)
Pit Depth (PP)

Pit Depth (PP)


 
Maintenance Deck Maintenance
60 4800 1800 2200 (By others) 60 4800 1800 2200 Deck
(By others)
90 5000 2050 2400 R4 R3 90 5000 2050 2400 R4 R3
105 5100 2050 2400 Receptacle Ladder Waterproof Finish 105 5100 2050 2400 Receptacle Ladder Waterproof Finish
(By others) (By others) (By others) (By others) (By others) (By others)
Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways. allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction Note : Machine room temperature should be maintained 2. The minimum machine room height should be 2800mm in case of the traction Note : Machine room temperature should be maintained
machine with double isolation pad. below 40C with ventilating fan and / or air conditioner machine with double isolation pad. below 40C with ventilating fan and/or air conditioner
3. Above dimentions are changeable according to the car exterior design. (if necessary) and humidity below 90%. 3. Above dimentions are changeable according to the car exterior design. (if necessary) and humidity below 90%.
1.  40C 90%  1.  40C 90% 
2. 2800mm   2. 2800mm  
3.    3.   

Standard Dimensions & Reactions (Unit : mm)


Standard Dimensions & Reactions (Unit : mm)

Clear Car Hoistway  M/C Room  M/C Room Pit Clear Car Hoistway  M/C Room  M/C Room Pit
Capacity Reaction (kg) Capacity Reaction (kg) Reaction (kg)
Speed 
Opening Internal External 1Car 2Cars Depth 1Car 2Cars Depth Reaction (kg) Speed 
Opening Internal External 1Car 2Cars Depth 1Car 2Cars Depth
(m/min)          (m/min)       
 

Persons kg OP CA CB AB X1 X2 Y S MX1 MX2 MY R1 R2 R2 R3 R4 Persons kg OP CA CB AB X1 X2 Y S MX1 MX2 MY R1 R2 R2 R3 R4



11 750 800 14001400 14601610 2450 5100 2000 1200 2900 5100 3500 6150 3450 6900 8700 7150 11 750 800 14001480 14601690 2450 5100 2000 1200 2900 5100 3500 6180 3450 6900 8700 7150
13 900 900 16001450 16601660 2650 5500 2050 1350 3300 5500 3550 6900 3750 7500 9700 7900 13 900 900 16001500 16601710 2650 5500 2050 1350 3300 5500 3550 6930 3750 7500 9700 7900
60 60
15 1000 900 16001570 16601780 2650 5500 2200 1350 3300 5500 3700 7200 3950 7900 10300 8300 15 1000 900 16001650 16601860 2650 5500 2200 1350 3300 5500 3700 7220 3950 7900 10300 8300
90 90
17 1150 1000 18001580 19001790 2850 6100 2200 1600 3500 6100 3700 9100 5450 10900 13150 10900 17 1150 1000 18001650 19001860 2850 6100 2200 1600 3500 6100 3700 9100 5450 10900 13150 10900
105 105
20 1350 1000 18001800 19002010 2850 6100 2400 1600 3500 6100 3900 9150 6750 13500 14550 11850 20 1350 1000 18001900 19002110 2850 6100 2400 1600 3500 6100 3900 9150 6750 13500 14550 11850
24 1600 1100 18002000 19002210 2850 6100 2600 1600 3500 6100 4100 10000 7150 14300 16100 12900 24 1600 1100 18002130 19002340 2850 6100 2600 1600 3500 6100 4100 10050 7190 14380 16100 12900
Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai. Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
2. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied 2. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied
above X1 dimension plus 100mm. above X1 dimension plus 100mm.
3. Consult Hyundai if the capacity is 10 persons and less. 3. Consult Hyundai if the capacity is 10 persons and less.
1.  1. 
2. CA1600mm CB1350mm  2. CA1600mm CB1350mm 
3. 1100mm1 X
X 100mm 3. 1100mm1 X
X 100mm
4. 11 4. 11

26 Observation Elevators 27
MRL ELEVATORS Layout Plan 
Machine-Room-Less Elevators Layout Plan

Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & Reactions (Unit : mm)

Capacity Clear Car Hoistway M/C Room Reaction (kg) pit Reaction (kg)
Type Speed 
Opening   
X Lighting (By others) (m/min)  Internal External

A
Hook (By others)
Persons kg OP CA CB AB XY R1 R2 R3 R4 R5 R6
R3 R1
8 550 800 13001090 13601300 21001700 4100 1950 700 1800 7500 6400
CA 9 600 800 13001160 13601370 21001800 4250 1980 750 1830 7800 6600
Top floor
(By others) 10 700 800 13001300 13601510 21001850 4500 2050 800 1900 8400 7000
Traction
CB

Machine 11 750 800 13001400 13601610 21001900 4650 2080 900 1950 8700 7200
Y

1-Side 60
Observation 900 15001400 15601610 23001900
90 13 900 5050 2250 1000 2100 9750 7950
1 930 (HC) 16001350 16601560 24001850
105

Over head (OH)


Lighting(By others)
R4 R2 15 1000 900 16001400 16601610 23001950 5400 2350 1050 2200 10300 8350
OP
17 1150 1000 18001400 19001610 26002150 5750 3450 1100 2800 13000 10700
20 1350 1000 18001600 19001810 26502450 6800 4800 1350 3150 14300 11600
24 1600 1100 20001600 21001810 28502500 7350 4950 1450 3300 15700 12500

Entrance Height (EH)


X
8 550 800 13001090 14601300 22001700 4250 2000 750 1940 7700 6600
A 9 600 800 13001160 14601370 22001800 4450 2030 800 1980 8000 6800
R3 R1 10 700 800 13001300 14601510 22001850 4750 2100 850 2080 8600 7200
11 750 800 13001400 14601610 22001900 4900 2150 950 2100 8900 7400
2-Side 60

Total Height (TH)


CA
Top floor 900 15001400 15601610 24001900
Observation 90 13 900 5400 2300 1050 2300 9950 8150
(By others)
2 930 (HC) 16001350 16601560 25001850
105
CB
Y
B

15 1000 900 16001400 17601610 24001950 5750 2400 1100 2500 10550 8550
17 1150 1000 18001400 19601610 27002150 6650 3500 1150 3150 13200 10900
Lighting (By others) 20 1350 1000 18001600 19601810 27002450 7730 4850 1400 3500 14450 11800
R4 R2
24 1600 1100 20001700 21601910 29002500 8250 5000 1500 3650 15900

Travel (TR)
OP 12700

Notes : 1. When non-standard capacities and dimensions (including fire protection doors) are required to meet the local code, please consult Hyundai.
Receptacle 2. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances should be made considering the sloping of the hoistways.
(By others) 3. The capacity in persons is calculated at 65kg / person. (EN81=75kg / person)
4. If the height of floor is over 11m, please consult Hyundai as to the needs for emergency exit.
Ladder 5. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied
(By others) above X1 dimension plus 100mm.
6. In case the emergency stop switch is applied to the counter weight, consult Hyundai.
7. If the car is heavier than 1000kg because of interior decoration in case of elevator for 15 persons (1000kg), consult Hyundai.
Lighting 1.  

Pit Depth (PP)

(By others) 2. 


Waterproof Finish
3. CA1600mm CB1350mm
4. 11m
(By others)
5. 
R5 R6 6. 1100mm 1 X
X 100mm
7.http:/www.hyundaielevator.co.kr   
8. 
9. 
10.15
Distribution Board
(By others)
(Unit : mm)
Notes : 1. Above dimensions are applied for car height of 2500mm (car internal height is 2300mm), For
Speed Overhead Pit Control Panel other applicable dimensions, consult Hyundai.
Control Person (m/min) (OH) (PP) (CP) 2. The minimum hoistway dimensions are shown on the above table. Therefore, some
Panel
 allowances should be made considering the sloping of the hoistways.
OP CP
3. When face to face arrangement is required, partitioning work for hoistway is required. (EN81)
(*) 60 4250 1750 4. If the hoistway is glass, consult Hyundai as it needs to finish joining glass. (EN81)
5. The lighting should be installed at the top and bottom of hoistway.
8 ~ 15 90 4350 1800 530
6. When non-standard capacities and dimensions are required to meet the local code, please
105 4400 2000 consult Hyundai Elevator.
60 4250 1800
Note : The lighting of hoistway should be installed less than
500mm from above the ceiling of hoistway and within 17 90 4350 1900 530 1. 2500mm 2300mm
 
500mm above the bottom of the pit. (By others) 105 4400 2000 2. 
3. 
60 4850 1800 530 4. 
500mm
20 ~24 90 5000 1900 630 5. 
500mm 

6. 
105 5000 2100 630

28 Observation Elevators 29
FRAMELESS GLASS WALLED ELEVATORS Layout Plan 
Gearless & Geared / MRL Elevators Layout Plan

Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & ReactionsGearless & Geared Elevators (Unit : mm)
Clear Car M/C Room Pit
Speed Capacity Hoistway M/C Room Reaction (kg) Reaction (kg)
Type 
Opening  
Lighting (By others) (m/min) Internal External  


Hook (By others)
Persons kg OP CA CB AB XY MX MY R1 R2 R5 R6
8 550 800 14001030 15601240 23001500 27003000 5450 3035 7800 6700
Gearless & Geared
MX 9 600 800 14001130 15601340 23001600 27003100 5640 3150 8200 7000

Traction 10 700 800 14001250 15601460 23001750 27003200 6010 3370 8750 7350
X
Machine 45
Frameless 11 750 800 14001350 15601560 23001850 27003350 6180 3480 9300 7800
A
Glass walled 60
13 900 900 16001350 17601560 25001850 31003350 6930 3795 10350 8550
 90
15 1000 900 16001500 17601710 25002000 31003500 7220 3970 11050 9050

Over head (OH)


105

Vent Fan (By others)


17 1150 1000 18001500 19601710 27502000 36003500 9100 5440 13650 11350
Vent Grille (By others)

CA 20 1350 1000 18001700 19601910 28902200 36003700 9144 6760 15300 12600
24 1600 1100 20001750 21601960 30902250 38003750 10020 7190 16800 13600
R1

R2

Entrance Height (EH)


Y

CB

Min. 900 (W)2100 (H)


Access Door (By others)

Notes : 1. The machine room reactions are changeable according to the size of hoistway and
Speed (m/min) Overhead (OH) Pit (PP) M/C Room Height (MH) center of car weight.
MY


2. The same dimension of passenger elevators apply to the others except the above.
Machine Room

45 4500 1500 2200 3. For NDFL-01 type, consult Hyundai Elevator since hoistway dimension and machine
room reactions for NDFL-01 type are changeable under different conditions.

Total Height (TH)


OP
60 4700 1500 2200
1. 
90 4900 1800 2400 2. 
3. NDFL-01
Control Distribution Board 105 5000 2100 2400 
Panel (By others)

Travel (TR)
Standard Dimensions & ReactionsMRL Elevators (Machine-Room-Less) (Unit : mm)
Receptacle
(By others) Capacity Clear Car Hoistway M/C Room Reaction (kg) Pit
Type Speed 
Opening  
Reaction (kg)
Ladder
(m/min)  Internal External 

(By others)
Persons kg OP CA CB AB XY R1 R2 R3 R4 R5 R6
8 550 800 13001100 14601310 21301750 4295 1870 660 1960 8150 7050
Gallery Window Lighting Lighting 9 600 800 13001190 14601400 21301800 4515 1910 740 2010 8500 7300
Pit Depth (PP)

MRL (By others)


(Machine-Room-Less)
(By others) (By others)
10 700 800 13001300 14601510 21301850 4820 2030 840 2100 9050 7650
X Waterproof Finish
45
(By others) Frameless 11 750 800 13001400 14601610 21301900 4975 2030 910 2110 9450 7950
A
Glass walled 60
R5 R6 13 900 900 15001400 16601610 23301900 5480 2240 1010 2350 10500 8700
 90
15 1000 900 16001400 17601610 24301900 5840 2385 1077 2521 11150 9150
R3 R1 105
17 1150 1000 18001400 19601610 27002150 6745 3220 1154 3185 13750 11450
20 1350 1000 18001600 19601810 27502350 7810 4515 1310 3530 15650 12950
CA
Distribution Board 24 1600 1100 20001700 21601910 29502400 8345 4650 1480 3720 16850 13650
(By others)
Y

Speed (m/min) Persons Overhead (OH) Pit (PP) Speed (m/min) Persons Overhead (OH) Pit (PP)
CB

Control
Panel
OP CP Max.15 4200 1500 45 4850
R4 R2
(*) 45, 60 1600
17 4200 1600 60 4850
OP 20, 24
90 4300 1800 90 5000 1800
Max.17
105 4400 2000 105 5000 2100

Note : The lighting of hoistway should be installed less than Notes : 1. The machine room reactions are changeable according to the size of hoistway and center of car weight.
500mm from above the ceiling of hoistway and within 2. The same dimension of passenger elevators apply to the others except the above.
500mm above the bottom of the pit. (By others) 3. For NDFL-01 type, consult Hyundai Elevator since hoistway dimension and machine room reactions for NDFL-01 type are changeable under different conditions.
500mm 1. 
500mm 
2. 
3. NDFL-01

30 Observation Elevators 31
WORKS TO BE DONE BY OTHER CONTRACTORS SPECIAL NOTES ON PLANNING THE INSTALLATION

The following works are not included in the elevator contract, and shall be done by other contractors In planning the installation of observation elevators, the architect as well as the product designer should
in accordance with the Hyundai Elevator's drawings and the applicable codes and regulations. consider the unique design features and special requirements of observation elevators. These special
The reference rules shown are from Code ANSI. notes should be carefully considered for both building construction and product engineering.

Building Work 14. Hoisting beams, trap doors, and other means of access to machine room
for maintenance and equipment removal purposes. (Rule 101.3d)
Observation Glass at Car & Hoistway Air-Conditioning & Ventilation
Hoistway 15. Cable guards in the machine room or secondary level. (Rule 104.1) Glass Window on Car The in-car temperature of the observation elevator can be highly increased
1. Clear, plumb hoistway with re resistant hatch walls as required by the The glass used for the car windows shall be 8mm thick tempered glass. Each because of the solar radiation heat, this factor should be considered in
applicable code. (Rule 100.1a) 16. Supports for machine and sheave beams and reactions including wall glass window shall not be over 1,250mm wide and 1,800mm high. planning the hoistway layout.
pockets and patching after beams are set in place. (Rule 105.1 to 105.5)
2. 75 bevel guards on all projections, recesses, or setbacks over 50mm For the passengers safety, the glass window shall be 500mm above car oor When required by the building, the air-conditioner can be installed on the
except on side used for loading or unloading. (Rule 100.6) unless it is especially required. observation elevator. When the air-conditioner is installed, a water drain is
required in the pit.
3. Venting of the hoistway as required by the applicable code or responsible For the passengers safety, the handrail shall be installed along the glass
authority. (Rule 100.4) Electrical Work window. The hoistway and the machine room should be properly ventilated to
prevent excessive temperature rise.
4. Supports for rail brackets at each oor, roof, and machine room. (Rule 200.9) Hoistway
Maximum allowable vertical spacing of rail supports without backing.
1. Light outlet for each elevator, in center of hoistway (or in machine room)
Glass Wall at Hoistway
(Rule 200.4 and 301.1) Divider beams 100mm between hoistway at each The glass used for the hoistway wall shall be safety-wired glass or
as indicated by Hyundai Elevator Company.
oor and roof, for guide rail bracket supports. (Rule 200.4, 200.9 and 301.1) tempered glass
2. Convenience outlet and light xture in pit with switch located adjacent to Hoistway Structures & Others
5. Recesses supports and patching as required to accommodate hall button To prevent excessive temperature rise in the hoistway, the hoistway glass
the access door. (Rule 106.1e)
boxes, signal xtures, etc. shall be radiant-heat absorbent glass. To facilitate the inspection, maintenance and cleaning of the car exteriors,
3. Wiring and piping work of emergency bell, interphone, etc. outside the an access hole and min. 500mm wide maintenance deck with a glass or
6. All barricades either outside elevator hoistways or between inside hoist- To enable the cleaning of the hoistway glass, the distance between the car concrete enclosure should be provided at the bottom of the hoistway (usu-
hoistway and the machine room.
ways as required. exterior and the glass wall shall be within the range of 200~300mm. ally at the basement level).
7. Dry pit reinforced to sustain normal vertical forces from rails and buffers. The glass wall shall be designed to prevent rain, moisture or dusts from To prevent the breakage of the hoistway glass from the outside, 1.8 meters
(Rule 106.1b and 109) Consult Hyundai Elevator Company for rail forces Machine Room entering the hoistway. high concrete enclosure shall be provided at ground level.
and buffer impacts. Where there is space below the pit oor that can be 4. Lighting, convenience outlets, ventilation, heating of machine room, and
occupied, consult Hyundai Elevator Company for special requirements. machinery space. (Rule 101.5) When the hoistway glass is directly exposed to the public, a fence should
(Rule 300.4) Cylinder hole, casings under the pit as required, and backlling be installed at min. 1.5 meters distance from the hoistway to prevent
around the cylinder casings when direct plunger type is to be installed. 5. Temperature should be maintained below 40C by a ventilating fan and /
access.
or air conditioner, if necessary, and humidity below 90%. Exterior Lighting
8. Where access to the pit is by means of the lowest hoistway entrance, When any especially-designed car top & bottom is required, the pit depth
vertical iron ladder extending 1060mm minimum above sill of access door. 6. A fused disconnect switch or circuit breaker for each elevator and light
The lamps used for the exterior illumination shall be designed for long life and overhead requirement may change.
(Rule 106.1d) switch located per the applicable code and where practicable located
and easy replacement.
adjacent to the door of the machine room. (Rule 210.5 and 306.7) When an outdoor type observation elevator is required for application in an
9. Entrance walls and nished oor are not to be constructed until after door The electric power requirements may vary per elevator models and illumi- outside openhoistway, special engineering is required for protection from
frames and sills are in place. Door frames are to be anchored to walls and 7. Feeder and branch wiring to the controller, including main-line switch
nation designs, however the proper power source required is AC 1, 220V, water, corrosion, ice, wind, dusts, etc.
properly grouted in place to maintain legal re rating. and convenience outlets.
20-30A range.
10. For application as indoor or outdoor observation elevator, a glass enclosure 8. Suitable power feeder and branch wiring circuits as required for
of at least 3.6m in height at the bottom landing is recommended for safety. elevators with power-operated doors, including disconnect switch or
circuit breaker.
For use as an outdoor observation elevator, a full-height glass enclosure is Heat Emission of Machine Room
required.
Emergency Provisions Q : (kcal/H)=W x V x F x N
W : Capacity (kg) N : Number of cars
Machine Room 9. Elevator remans and other emergency services wiring and interconnec-
V : Speed (m/min) F : Factor (1/40 - VVVF)
tions to automatic sprinkler systems or heat and smoke sensing devices
11. Enclosed and protected machine room. (Rule 101.1) furnished by others and installed to terminal points on the elevator
12. Access to the machine room and machinery space as required by the ap- controllers.
plicable code or responsible authority. (Rule 101.3) 10. When emergency power operation of elevators is required, the electrical
13. Reinforced concrete machine room oor slab or grating, as specied, which contractor should coordinate with Hyundai Elevator Company or local
distributor for operation requirements.
Data Required for Elevator Estimation
must not be placed over the hoistway until elevator machinery is set in
position. (Rule 100.3 for Traction Elevator) 11. Elevator remans and other emergency service requirements may differ
Clear access above ceiling or trench in oor, for oil line and wiring duct from each country. Consult Hyundai Elevator Company or local distributor Project Name and Location Machine Location (Overhead or Basement)
from machine room, if machine room is remote from elevator hoistway. (For for other local requirements.
Hydraulic Elevator) Applicable Code (ANSI, BS, JIS, CEN, etc.) Travel, Overhead & Pit Depth
Cutout through machine room wall, for oil line and wiring duct as required 12. When provisions for earthquake protection are required, consult Hyundai Required Delivery Hoistway width, Depth and Elevation
by Hyundai Elevators shop drawings. (For Hydraulic Elevator) Elevator Company for special requirements. Type & Units in System Door Width & Height
Capacity Car & Entrance Design
Speed Signal Fixtures
Control / Operation System Special Features Required
Landings & Openings (Front & Rear) Power Supply

32 Observation Elevators 33
WORKS TO BE DONE BY OTHER CONTRACTORS SPECIAL NOTES ON PLANNING THE INSTALLATION 

  




   

  



   

 
 

 

  


   
  

 
 


 
 



 N   
  
  

 
  

   
 
  6.8mm 

    

   

6.8mm  

 
 5mm
 



 12mm NN

 

 
(Sash) 
     N
NN  16mm    

  
 N

 
'FODF
  
0WFSIFBE

    
 

  2 LDBM)
87'/

  8 LH
  / N 0QFOUZQF 
 7 NNJO
  '(1/40 - VVVF)    

 _  

(60Hz, 380v) $BS


/'#   /'#  
"
L7"


"
L7"



LH
NNJO
LX
LH
NNJO
LX

               
"$ 7 _"
60 5.5 20 30 4 7 4 6 4 4 60 11 30 50 9 15 6 16 4 6 
6 90 7.5 20 30 6 10 4 6 4 6 15 90 15 40 75 13 23 10 25 6 10
(450) 105 7.5 20 40 7 12 4 10 4 6 (1000) 105 15 40 75 15 27 10 25 6 10
120 11 30 50 8 14 6 16 4 6 120 18.5 50 100 17 31 16 35 6 10
60 5.5 20 30 5 9 4 6 4 4 60 11 30 50 10 18 6 16 4 6
8 90 7.5 20 30 7 13 4 6 4 4 17 90 15 40 75 15 27 10 25 6 10
(550) 105 11 30 50 8 15 6 16 4 6 (1150) 105 18.5 50 100 17 31 16 35 6 10
120 11 30 50 9 17 6 16 4 6 120 22 60 100 20 36 16 35 6 10
60 5.5 20 30 5 9 4 6 4 4 60 15 30 60 12 21 6 16 4 6
9 90 11 30 50 8 14 6 16 4 6 20 90 18.5 50 100 17 31 16 35 6 10 
(600) 105 11 30 50 9 16 6 16 4 6 (1350) 105 22 50 100 20 37 16 35 6 10
120 11 30 60 10 19 6 16 4 10 120 30 75 125 23 42 16 35 10 16
60 7.5 20 40 6 11 4 10 4 6 60 15 40 75 14 25 10 25 6 10

10 90 11 30 50 9 16 6 16 4 6 24 90 22 50 100 21 37 16 35 6 10 
(700) 105 11 30 60 11 19 6 16 4 10 (1600) 105 22 60 125 24 43 16 35 10 16 
120 15 40 75 12 22 10 25 6 10 120 30 75 125 28 50 25 35 10 16  
60 7.5 20 40 6 12 4 10 4 6

11 90 11 30 50 10 17 6 16 4 6 Full Load5%
(750)   Max.50m50m 
105 11 30 60 11 20 10 16 4 10
120 15 40 75 13 23 10 25 6 10    
60 11 30 50 8 14 6 10 4 6  N





13 90 15 40 60 12 21 10 16 6 10  50 
(900) 105 15 40 75 14 24 10 25 6 10   195

120 18.5 50 100 15 28 16 35 6 10  3

34 Observation Elevators 35
INTERNATIONAL SALES & SERVICE NETWORK

Anywhere in the world,


You can nd the advanced service of Hyundai Elevator RUSSIA

KAZAKHSTAN
AZERBAIJAN
ITALY MONGOLIA
 TURKMENISTAN
KOREA
SEOUL
TURKEY SYRIA CHINA
TUNISIA
ICHEON JAPAN
LIBYA JORDAN IRAQ IRAN
ALGERIA BANGLADESH
EGYPT KUWAIT MEXICO
MOROCCO BAHRAIN QATAR PAKISTAN
U.A.E. MYANMAR
INDIA GUATEMALA
VIETNAM CUBA
SAUDI ARABIA OMAN PHILIPPINES
THAILAND PANAMA VENEZUELA

SUDAN COLOMBIA
ECUADOR
KENYA PERU
INDONESIA

BOLIVIA

DOMESTIC NETWORK GLOBAL NETWORK


v
HEAD OFFICE & FACTORY ALGERIA EGYPT KAZAKHSTAN PAKISTAN THAILAND
San 136-1, Ami- ri, Bubal-eup, Icheon-si, Gyeonggi-do 467-734, Korea Tel : 213-21-203785/87 Tel : 20-2-2262-4092 Tel : 7-727-240-47-08 Tel : 92-21-432-0604 Tel : 66-2348-8047
Tel : 82-2-3670-0653 / 0665 Fax : 82-2-3672-8763~4 Fax : 213-21-216444 Fax : 20-2-2262-4097 Fax : 7-727-240-47-08 Fax : 92-21-454-7405 Fax : 66-2240-3127

AZERBAIJAN GUATEMALA KENYA PANAMA TUNISIA
SEOUL OFFICE(INTL SALES DIV.) Tel : 994-12-418-0106 Tel : 502-2388-0000 Tel : 254-722-667984 Tel : 507-230-3166 Tel : 216-70-853-231
Fax : 994-12-567-18-77 Fax : 502-2388-0044 Fax : 254-722-667984 Fax : 507-230-3187 Fax : 216-71-754-361
9F East Bldg, Hyundai Group Bldg.,1-7 Yeonji-dong Jongno-gu, Seoul 110-754, Korea
Tel : 82-2-3670-0653 / 0665 Fax : 82-2-3672-8763~4 BAHRAIN INDIA KUWAIT PERU TURKEY
Tel : 973-17-702-468 Tel : 91-20-3250-2190 Tel : 965-2457925 Tel : 51-1-472-6868 Tel : 90-216-488-8000
Fax : 973-17-702-643 Fax : 91-20-2747-0568 Fax : 965-2423510 Fax : 51-1-472-6898 Fax : 90-216-488-9191
BANGLADESH INDONESIA LIBYA PHILIPPINES TURKMENISTAN

Tel : 880-1711-533047 Tel : 62-21-631-8444 Tel : 218-09173-5745 Tel : 632-716-0905 Tel : 993-12-2287-93
 02-3670-0560/055302-3670-096902-3670-0960 Fax : 993-12-3295-66
Fax : 880-2-8851045 Fax : 62-21-632-6288 Fax : 218-09173-5745 Fax : 632-714-8896
 031-273-0831  053-741-8064 BOLIVIA IRAN MEXICO QATAR UAE
 032-505-0430  051-512-6809 Tel : 591-3-339-9490 Tel : 98-21-8869-8727~36 Tel : 52-55-5379-7418 Tel : 974-436-6689 Abu Dhabi
 033-647-2601  052-272-2104 Fax : 591-3-339-9490 Fax : 98-21-8855-3741 Fax : 52-55-5663-2982 Fax : 974-436-6689 Tel : 971-2-671-1779
 042-536-1045  055-255-6354 Fax : 971-2-443-8822
CHINA IRAQ MONGOLIA RUSSIA Dubai
 063-278-3126  064-744-9619 Tel : 86-21-6485-8600 Tel : 964-79-01-336499 Tel : 976-1132-4414 Tel : 7-495-258-1521
Tel : 971-4-294-4475
 062-361-1633 Fax : 86-21-6485-3511 Fax : 964-1-7196892 Fax : 976-1132-4414 Fax : 7-495-514-0032 Fax : 971-4-294-4476
COLOMBIA ITALY MOROCCO SAUDI ARABIA VENEZUELA
467-734136-1 Tel : 574-444-9297 Tel : 39-045-630-4558 Tel : 212-2244-7900 Tel : 966-2-652-9000 Tel : 58-212-232-8263
110-7541-789 Fax : 574-444-9297 Fax : 39-045-790-3371 Fax : 212-2230-3714 Fax : 966-2-652-9090 Fax : 58-212-232-7178
CUBA JAPAN MYANMAR SUDAN VIETNAM
www.hyundaielevator.co.kr
Tel : 537-699-3412 Tel : 81-3-3436-5117 Tel : 95-1-385-3404 Tel : 249-183-230-383 Tel : 84-43-572-4588
Fax : 537-699-3431 Fax : 81-3-3436-5198 Fax : 95-1-250-485 Fax : 249-183-230-364 Fax : 84-43-572-4699
SYRIA
ECUADOR JORDAN OMAN
Tel : 593-2-2568-370 Tel : 962-79-5526-713 Tel : 968-9286-4334 Tel : 963-933-234134

1 5 7 7 - 0 6 0 3 Fax : 593-2-2553-761 Fax : 962-6-5699-014 Fax : 968-2449-9307 Fax : 963-114-469-8666

36 Observation Elevators 37