Contents
3 Standby Generator Systems
Description Page
3 Standby Generators
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T3-3
3 Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T3-3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-5
3 Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . . V1-T3-6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-6
3
EGENA20 EGENX27
3
3
3
3
3
3 Product Description Application Description Features, Benefits
and Functions
3 A standby generator system
is a package of equipment
Eatons air-cooled standby
generators offer fully
Standby generator systems
are most often used in Eatons generator systems
specifically designed to automatic operation and residential, agricultural
3 provide substitute electrical provide most homeowners and light commercial
offer a wide range of
features. All systems feature:
power to a residence in the with enough power for applications. Comfort and
3 event of a utility power complete whole house safety are key concerns Powerful engines
outage. These systems are comfort. These units all of many homeowners Reliable Eaton transfer
3 comprised of a generator,
transfer switch and the
operate at ultra quiet
66 dB, or less, sound level.
who are dependent on
an uninterrupted supply
switches and control
systems using switching
3 connections necessary for
installation. Eatons standby Liquid-Cooled Standby
of electricity.
duty rated circuit breakers
Weekly exercise function
generator line consists of Eatons liquid-cooled The increase in our
3 air-cooled and liquid-cooled generators feature automotive dependence on power is
due in part to the popularity of
Automatic transfer
systems feature automatic
models ranging from 9000 style engines that range from
3 home offices and in-home start/stop
watts up to 150,000 watts. 22 to 150 kW of power
output. These units run so health care. Many regions of
Air-Cooled Standby the United States experience
3 Eatons air-cooled generators
quietly that youll forget that
you own a generator until you periodic power outages
Standards and
Certifications
range from 9 to 22 kW and need it. These units are due to extreme weather
3 these units are perfect for available in steel or aluminum conditions such as ice and CSA, cUL and UL 2200
listed and approved
automatically backing up enclosures and are available in snowstorms, heat waves,
3 every circuit within a home single- and three-phase in four tornadoes or hurricanes. SCAQMD (selected
models only)
such as air conditioner units, voltages: 120/240 V, single- Eaton highly recommends
3 refrigerators, lighting, furnace
fans, sump pumps and water
phase; 120/208 V, three-
phase; 240 V, three-phase;
that any generator system
All transfer switches are
UL 67 and UL 1008 listed
be installed by a qualified
3 pumps. and 277/480 V, three-phase. electrician and/or generator
installer.
as Transfer Switches
All generators are
UL 2200 listed
3
3
3
3
3
3
3
V1-T3-2 Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com
Residential Standby Backup Power Solutions
Standby Generators
3.1
Catalog Number Selection
3
Air-Cooled Generators
3
EGEN A 11
3
Type
A = Aluminum
Rated Power
(LP/NG) 3
9 = 9/8 kW
11 = 11/10 kW
16 = 16/16 kW
3
3
20 = 20/18 kW
22 = 22/19.5 kW
3
Liquid-Cooled Generators
3
EGEN X 27 A N A N
3
kW Rating SCAQMD Compliance
EGENX Series kW Rating Enclosure N = No 3
22 36 EGEN Series Voltage Required A = Aluminum Y = Yes
25
27
38
45
70
80
A = Single-phase 120/240 V
G = Three-phase 208 V
Fuel Type
N = Natural gas
3
30 48 100 J = Three-phase 240 V
3
L = Liquid propane
32 60 130 K = Three-phase 480 V
150
3
3
3
3
3
3
3
Product Selection
Air-Cooled Generators
3
EGENA_
Maximum
Rated Main Line
3
Rated Amperes Circuit Sound Limited
Power kW at 240 Vac Breaker Enclosure Engine Number of SCAQMD Emissions Warranty Catalog 3
(LP/NG) (LP/NG) Amperes Material Size Cylinders Fuel Type Compliant (dB at 7 m) (yrs) Number 1
9/8 37.5/33.3 40 Aluminum 426 cc 1 Liquid propane/
natural gas
Yes 66 5 EGENA9 3
11/10 45.8/41.7 50 Aluminum 530 cc 2 Liquid propane/
natural gas
Yes 63 5 EGENA11 3
16/16 66.6/66.6 65/55 Aluminum 999 cc 2 Liquid propane/
natural gas
Yes 66 5 EGENA16 3
20/18 83.3/75.0 90 Aluminum 999 cc 2 Liquid propane/
natural gas
Yes 66 5 EGENA20 2
3
22/19.5 91.7/81.2 100 Aluminum 999 cc 2 Liquid propane/
natural gas
Yes 67 5 EGENA22 2
3
Notes
1 Battery to be furnished by others. Recommended size: Group 26R, 12 V, 225 CCA min.
3
3
2 Includes base fascia (No. EGENFASCIA) as standard.
3
Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com V1-T3-3
3.1 Residential Standby Backup Power Solutions
Standby Generators
Liquid-Cooled Generators 12
3 EGENX27ANAN
Catalog Number kW Voltages SCAQMD
Prefix Rating Available Fuel Type 3 Enclosure Compliance 4
3 EGENX22 22 A120/240 V, single-phase NNG/LP field convertible AAluminum NNo
G208 V, three-phase (Default set up for NG)
3 J240 V, three-phase
EGENX25 25 A120/240 V, single-phase NNG/LP field convertible AAluminum NNo
3 G208 V, three-phase (Default set up for NG)
J240 V, three-phase
3 EGENX30 30
J240 V, three-phase
A120/240 V, single-phase NNG/LP field convertible AAluminum NNo
G208 V, three-phase (Default set up for NG)
3 J240 V, three-phase
EGENX32 32 A120/240 V, single-phase NNG/LP field convertible AAluminum NNo
3 G208 V, three-phase (Default set up for NG)
J240 V, three-phase
3 K480 V, three-phase
EGENX36 36 A120/240 V, single-phase NNG/LP field convertible AAluminum YYes
3 G208 V, three-phase
J240 V, three-phase
(Default set up for NG)
NNo
3 EGENX38 38
K480 V, three-phase
A120/240 V, single-phase NNG/LP field convertible AAluminum NNo
G208 V, three-phase (Default set up for NG)
3 J240 V, three-phase
K480 V, three-phase
3 EGENX45 45 A120/240 V, single-phase NNG/LP field convertible AAluminum YYes
G208 V, three-phase (Default set up for NG) NNo
3 J240 V, three-phase
K480 V, three-phase
3 J240 V, three-phase
K480 V, three-phase
EGENX60 60 A120/240 V, single-phase NNatural gas AAluminum NNo
3 G208 V, three-phase LLiquid propane
J240 V, three-phase
3 K480 V, three-phase
EGEN70 70 A120/240 V, single-phase NNatural gas AAluminum YYes
3 G208 V, three-phase
J240 V, three-phase
LLiquid propane NNo
3 EGEN80 80
K480 V, three-phase
A120/240 V, single-phase NNatural gas AAluminum NNo
LLiquid propane
3 G208 V, three-phase
J240 V, three-phase
K480 V, three-phase
3 EGEN100 100 A120/240 V, single-phase NNatural gas AAluminum YYes
G208 V, three-phase LLiquid propane
3 J240 V, three-phase
K480 V, three-phase
3 EGEN130 130 A120/240 V, single-phase
G208 V, three-phase
NNatural gas
LLiquid propane
AAluminum YYes
3 J240 V, three-phase
K480 V, three-phase
3
EGEN150 150 A120/240 V, single-phase NNatural gas AAluminum YYes
G208 V, three-phase LLiquid propane
J240 V, three-phase
3 K480 V, three-phase
3 Notes
1 All liquid-cooled models suitable for optional standby backup power only, as dictated by NEC Article 702/NFPA 70. Not suitable for neither emergency nor legally
3
4 South Coast Air Quality Management District (CA and MA). Check your local requirements.
5 For all three-phase ATS requirements, please contact EatonCare.
3 Device
Common
Running Watts Liquid-Cooled Standby
3 Air Conditioner (40,000 btu) 6000 EGENX22 62.00 (1574.8) 29.00 (736.6) 34.00 (863.6) 895 (406.3)
Battery charger (20 amp) 500 EGENX25 63.00 (1600.2) 30.00 (762.0) 35.00 (889.0) 875 (397.3)
3 Circular saw (6-1/2-inch) 8001000 EGENX27 64.00 (1625.6) 31.00 (787.4) 36.00 (914.4) 891 (404.5)
Clothes dryer (electric) 5750 EGENX30 60.00 (1651.0) 32.00 (812.8) 37.00 (939.8) 935 (424.5)
3 Clothes dryer (gas) 700 EGENX32 76.80 (1950.0) 35.00 (889.0) 46.10 (1171.0) 600 (1333.0)
Clothes washer 1150
3
EGENX36 77.00 (1955.8) 34.00 (863.6) 45.00 (1143.0) 1683 (764.1)
Coffee maker 1750 EGENX38 76.80 (1950.0) 35.00 (889.0) 46.10 (1171.0) 600 (1333.0)
3
Compressor (1 hp) 2000
EGENX45 78.00 (1981.2) 35.00 (889.0) 46.00 (1168.4) 1414 (642.0)
Compressor (1/2 hp) 1400
EGENX48 79.00 (2006.6) 36.00 (914.4) 47.00 (1193.8) 1703 (773.2)
3 Compressor (3/4 hp)
Curling iron
1800
700
EGENX60 4 80.00 (2032.0) 37.00 (939.8) 48.00 (1219.2) 1650 (749.1)
EGEN70 4 97.00 (2463.8) 37.00 (939.8) 48.00 (1219.2) 2185 (992.0)
3 Dehumidifier 650
EGEN80 4 115.00 (2921.0) 36.80 (934.7) 79.00 (2006.6) 2010 (912.5)
Electric blanket 400
3 Electric range (per element) 1500
EGEN100 4
EGEN130 4
116.00 (2946.4)
117.00 (2971.8)
36.80 (934.7)
36.80 (934.7)
80.00 (2032.0)
81.00 (2057.4)
2705 (1228.1)
2873 (1304.3)
Electric skillet 1250
3 Freezer 700 EGEN150 4 118.00 (2997.2) 36.80 (934.7) 82.00 (2082.8) 2666 (1210.4)
appliances and motors can usually be found on a decal affixed to the device.
3
Hair dryer 1200 2 If the appliance, tool or motor does not give wattage, multiply 120 volts times the ampere
Hand drill 2501100 rating to determine watts (volts x amps = watts) for single-phase only.
3 Induction motors require about three times more power (in watts) to start up than to run.
3 Iron
Jet pump
1200
800
This surge lasts for only a few seconds. Be sure to take this into account when calculating
the total capacity of the load that will be energized by the backup power system. To correctly
3 Light bulb 100 configure the desired wattage, add the amperage of the inrush of the largest motor to the
total running wattage of all other connected loads.
Microwave oven 7001000 Figure the watts required to start the largest motor.
3 Milk cooler 1100 Add that to the total running watts of all other connected loads.
4 All weights provided for steel enclosures only, if applicable.
Oil burner on furnace 300
3 Oil fired space heater (140,000 btu) 400
Oil fired space heater (30,000 btu) 150
3 Oil fired space heater (85,000 btu) 225
Radio 50200
3 Refrigerator 700
3
Slow cooker 200
Submersible pump (1 hp) 2000
3 Portable Generators
Approx.
3 Engine
Fuel
Tank
Running
Time at
Warranty
Residential/
Running Starting Displacement/ Startup Capacity 1/2 load Battery Outlets Commercial Catalog
3 Watts Watts Type Method (gal) 1 (hrs) Included Configuration (yrs) Number
General Purpose (49-State)
3 EGENP5500 5500 6875 389 cc/OHV Manual 7.2 10 No 1 x 30 A L14-30R (twist lock), 2 x 20 A 5-20R duplex 2/1 Ltd EGENP5500
3
3
3 EGENP6500 6500 8125 389 cc/OHV Manual 7.2 10 No 1 x 30 A L14-30R (twist lock), 2 x 20 A 5-20R duplex 2/1 Ltd EGENP6500
3
3
3 EGENP6500E 6500 8125 389 cc/OHV Manual/ 7.2 10 Yes 1 x 30 A L14-30R (twist lock), 2 x 120 A 5-20R duplex 2/1 Ltd EGENP6500E
3
electric
3
3
EGENP7500E 7500 9375 420 cc/OHV Manual/ 8.0 12 Yes 1 x 30 A L14-30R (twist lock), 2 x 20 A 5-20R duplex 2/1 Ltd EGENP7500E
3 electric
3
3
3 Note
1 Requires gasoline as fuel to operate.
3
3
3
3
3
V1-T3-8 Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com
Residential Standby Backup Power Solutions
Portable Generators
3.2
Portable Generators, continued
Approx.
3
Fuel Running Warranty
Engine Tank
Running Starting Displacement/ Startup Capacity
Time at
1/2 load Battery Outlets
Residential/
Commercial Catalog
3
3
Watts Watts Type Method (gal) 1 (hrs) Included Configuration (yrs) Number
General Purpose (49-State), continued
EGENP15000E 15000 22500 992 cc/OHVI Manual/ 16.0
electric
12 Yes 1 x 50 A 14-50R, 1 x 30 A L14-30R (twist lock),
2 x 30 A L5-30R (twist lock), 1 x 20 A 5-20R duplex,
2/1 Ltd EGENP15000E 3
3
1 x 20 A GFCI 5-20R duplex
3
EGENP17500E 17500 26250 992 cc/OHVI Manual/ 16.0 10 Yes 1 x 50 A 14-50R, 1 x 30 A L14-30R (twist lock), 2/1 Ltd EGENP17500E 3
electric 1 x 30 A L5-30R (twist lock),1 x 20 A 5-20R duplex,
1 x 20 A 5-20R GFCI duplex
3
3
XG Series
3
EGENP7000EX 7000 8750 407 cc/OHVI Manual/ 9
electric
10 Yes 1 x 30 A L14-30R (twist lock), 2 x 20 A GFCI 5-20R duplex 2/1 Ltd EGENP7000EX
3
3
3
EGENP8000EX 8000 10000 407 cc/OHVI Manual/ 10 10 Yes 1 x 30 A L14-30R (twist lock), 2 x 20 A GFCI 5-20R duplex 2/1 Ltd EGENP8000EX 3
electric
3
3
EGENP10000EX 10000 12500 530 cc/OHVI Manual/ 10 10 Yes 1 x 50 A 14-50R, 1 x 30 A L14-30R (twist lock), 2/1 Ltd EGENP10000EX
3
electric 1 x 30 A L5-30R (twist Lock), 2 x 20 A GFCI 5-20R duplex
3
3
3
EGENP5500CA
CARB 2 Compliant (Required in California Only)
5500 6875 389 cc/OHV Manual 7.2 10 No 1 x 30 A L14-30R (twist lock), 2 x 20 A GFCI 5-20R duplex 2/1 Ltd EGENP5500CA
3
3
3
3
EGENP6500CA 6500 8125 389 cc/OHV Manual 7.2 10 No 1 x 30 A L14-30R (twist lock), 2 x 120 A 5-20R duplex 2/1 Ltd EGENP6500CA
3
3
3
Notes
1 Requires gasoline as fuel to operate.
3
2 California Air Resources Board.
3
3
Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com V1-T3-9
3.2 Residential Standby Backup Power Solutions
Portable Generators
Dimensions
3 Approximate Dimensions in Inches (mm)
3 Portable Generators
3 Catalog
Number Length Width Height
Weight
Lbs (kg)
3 EGENP7000EX
EGENP7500E
31.00 (787.4)
27.25 (692.2)
25.50 (647.7)
27.00 (685.8)
28.00 (711.2)
25.00 (635.0)
245.0 (111.2)
191.5 (86.9)
3
EGENP17500E 48.50 (1231.9) 31.00 (787.4) 39.50 (1003.3) 390.0 (177.1)
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V1-T3-10 Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com
Residential Standby Backup Power Solutions
Automatic Transfer Switches
3.3
Contents
Residential Automatic Transfer Switches
Description Page
3
Automatic Transfer Switches 3
Standards and Certifications . . . . . . . . . . . . . . V1-T3-12
Catalog Number Selection . . . . . . . . . . . . . . . . V1-T3-12 3
Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T3-13
ATS Ready Loadcenter . . . . . . . . . . . . . . . . V1-T3-14 3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-15
3
3
3
3
3
3
Product Description Application Description 3
50, 100, 150, 200 and 400 A Green Line of Automatic 50, 100, 150, 200 and 400 A 3
Fully Automatic Transfer Switches Switches
All Eaton automatic transfer With the rising cost of 100, 200 and 400 A switches 3
switches (ATS) monitor utility commodities and fuel are capable of whole house
and generator voltages and
will automatically connect to
in todays economy,
consumers are concerned
power transfer in residential/
small business applications.
3
the appropriate source of
power. Eaton offers two
with maximizing the value
of their purchases. 3
types of automatic transfer 50 AIndoor InstallationSelected Load Pre-Wired
switches to suit your personal Electrical loads are now
Meter 50 A
3
backup power needsthe intelligently managed with
Indoor Transfer
standard ATS EGSX series Eatons Green Line of
automatic transfer switches.
Standby
Generator
Switch 3
with load shedding 100/200 A
The active load management
capabilities and the Green
ATS EGSU series that inside each Green ATS allows
Service Panel 3
the consumer to use 100% of
provides a truly active load
management solution. the power rated output of the Sound 3
generator and/or use a Attenuated
smaller generator, reducing
upfront installation costs and
Enclosure
3
Fuel Supply
saving on ongoing fuel
consumption costs.
(NG or LP)
3
As a part of Eatons
commitment to quality,
Air Conditioner 3
every Green ATS, at no
extra cost, will ship with a
100/200 AOutdoor InstallationWhole House Pre-Wired 3
CHSPT2ULTRA whole surge
protector, which will help
Standby
Service
Disconnect
Meter
3
prevent potential damage
to valued electronics caused
Generator
100/200 A 3
by power surges in the Outdoor Transfer Switch
utility line.
Sound Low Voltage
3
3
Attenuated Disconnect
Enclosure
Fuel Supply
(NG or LP) 3
100/200 A 3
Air Conditioner Service Panel
3
Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com V1-T3-11
3.3 Residential Standby Backup Power Solutions
Automatic Transfer Switches
Standards and
3 Certifications
3
UL 1008 listed
UL 67 listed
3
3
3 Catalog Number Selection
3 Standard Automatic Transfer SwitchesEGSX Series
3 EGSX 200 NSEA
3
Service Entrance Rated
3 Type
EGSX = Eaton EGSX transfer
Ampere
Rating
Loadcenter
(CH Type, Integral)
NSEA = Service entrance
(normal source only)
switch series 50 = 50 A Blank = None A = Non-service entrance
3 100 = 100 A L12 = 12 circuits N1
150 = 150 A L12R = 12 circuits N3R
3 200 = 200 A
400 = 400 A
L24R = 24 circuits N3R
3
Green Automatic Transfer SwitchesEGSU Series
3
EGSU 200 NSE ACA
3
3
Load Management
Type Ampere ACA = Active load management
Service Entrance Rated
EGSU = Eaton EGSU Green universal Rating Loadcenter
3 transfer switch series 100 = 100 A
150 = 150 A
(CH Type, Integral)
NSE = Service entrance
(normal source only)
Blank = None Blank = Non-service entrance
3
200 = 200 A L24 = 24 circuits
400 = 400 A
3
3
3
3
3
3
3
3
3
3
3
3
3
V1-T3-12 Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com
Residential Standby Backup Power Solutions
Automatic Transfer Switches
3.3
Product Selection
3
EGSX50L12R Standard Automatic Transfer Switches 1 3
Service
No. of
Load Contactor No. of Withstand No. of Most Common 3
Ampere Entrance Shed Wire Size Cables Current (rms) Circuits Frequency Enclosure Generator Catalog
Rating Voltage Rated Contacts Range(s) per Phase at 240 Vac Included 2 (Hz) Type Sizes (kW) 2 Number
3
50 120/240 No 2 #14#6 1 5000 12 50/60 NEMA 1 9, 11 EGSX50L12
(indoor)
3
50 120/240 No 2 #14#6 1 5000 12 50/60 NEMA 3R 9, 11 EGSX50L12R
(outdoor)
3
100 120/240 No 2 #14#2/0 1 10,000 50/60 NEMA 3R 9, 11, 16 EGSX100A
3
(outdoor)
150 120/240 Yes 2 #4300 kcmil 1 10,000 50/60 NEMA 3R 16, 20, 22 EGSX150NSEA
(outdoor)
200 120/240 No 2 #4300 kcmil 1 10,000 50/60 NEMA 3R 16, 20, 22 EGSX200A 3
(outdoor)
200 120/240 Yes 2 #4300 kcmil 1 10,000 50/60 NEMA 3R 16, 20, 22 EGSX200NSEA 3
(outdoor)
400 120/240 Yes 2 750 kcmil2 1/2 35,000 50/60 NEMA 3R >22 EGSX400NSEA 3
300 kcmil1/0 (outdoor)
3
EGSU200NSEACA Green Automatic Transfer Switches 4Featuring Active Load Management Technology 3
Service Contactor No. of Withstand No. of Most Common
Ampere Entrance
Rating Voltage Rated
Wire Size
Range(s)
Cables
per Phase
Current (rms) Circuits
at 240 Vac Included 2
Frequency
(Hz)
Enclosure
Type
Generator
Sizes (kW) 3
Catalog
Number 5
3
100 120/240 No #14#2/0 1 10,000 50/60 NEMA 3R
(outdoor)
9, 11, 16 EGSU100ACA 3
100 120/240 Yes #14#2/0 1 10,000 50/60 NEMA 3R
(outdoor)
9, 11, 16 EGSU100NSEACA
3
100 120/240 No #14#2/0 1 10,000 24 50/60 NEMA 3R
(outdoor)
9, 11, 16 EGSU100L24RACA
3
150 120/240 Yes #4300 kcmil 1 10,000 50/60 NEMA 3R
(outdoor)
16, 20, 22 EGSU150NSEACA
3
3
200 120/240 No #4300 kcmil 1 10,000 50/60 NEMA 3R 16, 20, 22 EGSU200ACA
(outdoor)
200 120/240 Yes #4300 kcmil 1 10,000 50/60 NEMA 3R 16, 20, 22 EGSU200NSEACA
(outdoor) 3
400 120/240 Yes 750 kcmil2 1/2 35,000 50/60 NEMA 3R >22 EGSU400NSEACA
300 kcmil1/0 (outdoor) 3
3
Notes
1 Standard ATS EGSX Series compatible with Eaton generators only.
2 Uses CH type circuit breakers.
3 For reference only. Generator size must be determined with proper/actual load calculations.
4 UNIVERSAL ATS: compatible with any single-phase, 120/240 V generator brand.
3
5 Whole house surge Cat. No. CHSPT2ULTRA included in every Green ATS EGSU Series.
3
3
3
3
3
3
Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com V1-T3-13
3.3 Residential Standby Backup Power Solutions
Automatic Transfer Switches
hurricanes and snow/ice electrical contractors the single-phase MCB air-cooled generators
storms, to the increasing flexibility to install a generator 36-circuit loadcenter
3 CH cover included
power outage concerns and ready system or to install a 50 A ATS EGSX type kit
an aging electrical loadcenter and easily add an
Lifetime warranty on CH
for factory or field
3 infrastructure, backup power
is more important than ever.
ATS in the future. Backup
power had never been that
installation (compatible
loadcenter and breakers
NEMA 1 design
with Eaton generators only)
3 Eatons ATS Ready loadcenter versatile before. UL Listed
3
3
3
3
3
3
CHEGSX50KIT ATS EGSX kit for ATS Ready loadcenter CHEGSX50KIT
3 Field-installable automatic transfer switch kit
ATS Ready loadcenter CH36B200EGP must be ordered separately
Intuitive, easy installation
3 Compatible with Eaton generators only
3
3
3
CH36B200EGPK ATS Ready LC with factory-installed ATS kit CH36B200EGPK
3 Factory assembled
Compatible with Eaton generator only. Generator needed to complete backup power system
Contents
3 All Panels are Manufactured in the USA and Meet UL 1008
Description Page
3 Manual Transfer Switches
Standards and Certifications . . . . . . . . . . . . . . V1-T3-17
3 Reference Information . . . . . . . . . . . . . . . . . . V1-T3-17
Product Selection . . . . . . . . . . . . . . . . . . . . . . V1-T3-18
3 Technical Data and Specifications . . . . . . . . . . V1-T3-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-19
3 Learn
3
Online
3
3
3
3
3 Product Description Application Description Features, Benefits and Functions
3 A manual transfer switch is a
device that is mounted next
Manual transfer switches
are most often used in
Eaton offers two manual
transfer switch backup power
to the loadcenter (distribution residential, agricultural solutions:
3 panel) in the home or small and light commercial
business. The manual applications. Comfort and
Manual transfer switches
3 transfer switch is used in safety are key concerns Generator panels
conjunction with a portable of many homeowners
Manual Transfer Switches
3 backup power generator and
serves the purpose of turning
who are dependent on
an uninterrupted supply Panel and components
sold separately
3 selected circuits on and off
during a power outage. The
of electricity.
Hardwired generator
transfer switch panel allows The increase in our connection
3 the owner to start up a dependence on power is
due in part to the popularity
Ideal for new construction/ Manual Transfer Switch
generator to restore power to larger loads Indoor Design
3 critical circuits when utility of home offices and in-home
health care. Various heavily Sturdy copper bus
power is not available. construction
populated regions of the
3 The owner designates which United States experience Uses CH and CHT circuit
circuits are critical, such as periodic power outages breaker types (sold
3 the refrigerator and certain due to extreme weather separately)
lights. Sometimes called conditions, such as ice and Mechanically interlocked
3 emergency power panels or
emergency generator panels,
snowstorms, heat waves,
tornadoes or hurricanes.
main disconnects to
prevent paralleling of
3 manual transfer switch
panels provide the
These regions that include
the Pacific Northwest,
normal and emergency
power source
homeowner or small Atlantic Coast and the Gulf
3 business owner with a safe Coast are the strongest
Indoor and outdoor
designs available
and easy way to continue markets for portable Manual Transfer Switch
3 using electrical appliances generators and manual Indoor/Outdoor Design
when the utility power transfer switches.
3 is unavailable temporarily.
3
3
3
3
3
V1-T3-16 Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com
Residential Standby Backup Power Solutions
Manual Transfer Switches
3.4
Standards and Certifications
UL 67 listed
3
Generator Panels
Mechanically interlocked
UL 1008 listed
3
main disconnects prevent
paralleling of normal and
emergency power source
3
Panel and components
sold separately
3
Reference Information
Integral plug-in generator
connection (power inlet
3
box)
All circuit breakers are
Cross-Reference
Catalog Number
3
Number Ampere
includedswitching
duty rated
Watts of Circuits Rating Eaton Gen/Tran 1 EmerGen 1 Square D Generac 2
3
5000 48 30 CH48GEN3060R QO48M30DSGP
Includes dual wattmeters
for load balancing 15,000 816 60 CH816GEN6060 QO48M60DSGP 3
Indoor and outdoor 5000 6 20 CH6EGEN2060 20216 6-5000
designs available 5000 6 20 CH6EGEN2060R R20216 6-5000 + RTE657 3
5000
5000
6
6
20
20
CH6EGEN2060SU
CH6EGEN2060RSU
3
7500 10 30 CH10EGEN3060 302110-20 10-7500 3
7500 10 30 CH10EGEN3060R R30211-20 10-7500 + RTE1075
7500 10 30 CH10EGEN3060SUR 3
7500 10 30 CH10EGEN3060RSU
7500 10 30 CH10GEN5030SN
3
7500 10 30 CH10GEN5030RSN
3
12,000 10 50 CH10GEN5050SN
Generator Panel
12,000 10 50 CH10GEN5050RSN 3
Indoor Design
3
Notes
1 Gen/Trans device is not supplied with a power cord.
2 Generac device is 7200 maximum watts on six-circuit device and 12,000 maximum watts on 10-circuit device.
3
3
3
3
3
Generator Panel
Outdoor Design
3
3
3
3
3
3
3
3
3
Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com V1-T3-17
3.4 Residential Standby Backup Power Solutions
Manual Transfer Switches
Product Selection
3
3 Manual Transfer Switches and Generator Panels Selection
3 NEMA 3R
NEMA 1
5000
10,000
48
816
30
60
Provision
Provision
Provision
Provision
None
None
CH48GEN3060R
CH816GEN6060
3 Generator Panel
NEMA 1 5000 6 20 60/20 51P1511P20 None CH6EGEN2060
3 NEMA 3R 5000 6 20 60/20 51P1511P20 None CH6EGEN2060R
NEMA 1 5000 6 20 60/20 51P1511P20 Two-pole surge protector CH6EGEN2060SUR
3 NEMA 3R 5000 6 20 60/20 51P1511P20 Two-pole surge protector CH6EGEN2060RSU
3 NEMA 1
NEMA 3R
7500
7500
10
10
30
30
60/30
60/30
61P1521P2012P30
61P1521P2012P30
None
None
CH10EGEN3060
CH10EGEN3060R
3
NEMA 1 7500 10 30 50/30 61P15, 21P20, 12P30 None CH10GEN5030SN
NEMA 3R 7500 10 30 50/30 61P15, 21P20, 12P30 None CH10GEN5030RSN
and ground
Power inlet box must be connected to a circuit breaker for
3
generator protection
3
Installation Diagrams
3
Manual Transfer SwitchesIndoor Installation Diagram Generator PanelsIndoor Installation Diagram 3
Eaton
Manual Transfer Switch Utility
Generator Panel Utility
Power
3
Power Feed
Power
Feed
Power
Inlet
Existing
3
Inlet Box*
3
Existing Main
Box* Main Power
Power Power Power Panel
Cord* Panel
(Loadcenter)
Cord* (Loadcenter)
3
Two-Pole, 60 A Breaker*
to Feed the Emergency
Two-Pole, 60 A Breaker*
to Feed the Emergency 3
Power Panel From Your Generator Panel From
Hardwired
Existing Main Power Panel
(Loadcenter)
Your Existing Main
Power Panel (Loadcenter) 3
Generator* Electrical
Connection*
* Not Included Generator* Electrical Wiring
or Power Cord*
Prewired Connector
for Faster Installation
3
- Included * Not Included
3
Manual Transfer SwitchesOutdoor Installation Diagram Generator PanelsOutdoor Installation Diagram 3
3
Two-Pole, 60 A Generator Panel
Eaton Breaker* to Feed
Manual Transfer Switch Utility the Emergency
Power Feed
Power Existing
Generator Panel
From Your 3
Inlet Main Existing Main
3
Box* Power Panel Prewired
Power
Power Panel
(Loadcenter) Connector
Cord* for Faster
Installation - 3
Two-Pole, 60 A Breaker* Included
to Feed the Emergency
Power Panel From Your
Utility
Power 3
Existing Main Power Panel Feed
(Loadcenter)
3
3
Generator* Hardwired Electrical Connection* * Not Included Power Cord*
Generator*
*Not Included
3
Dimensions 3
Approximate Dimensions in Inches (mm)
3
Manual Transfer Switch Generator Panel
3
Enclosure Weight Enclosure Weight Lbs (kg)
Type Height Width Depth Lbs (kg) Type Height Width Depth 6-Circuit 10-Circuit 3
NEMA 1 16.75 (425.5) 14.31 (363.5) 3.88 (98.5) 25 (11) NEMA 1 13.23 (336.0) 11.41 (289.8) 4.10 (104.1) 24 (11) 26 (12)
NEMA 3R 13.00 (330.2) 11.00 (279.4) 3.56 (90.4) 14 (6) NEMA 3R 17.12 (434.8) 9.45 (240.0) 7.16 (181.9) 29 (13) 31 (14) 3
3
3
Volume 1Residential and Light Commercial CA08100002EJanuary 2017 www.eaton.com V1-T3-19