I i -Interactor System
Standard configuration:
1 i-Cam
2 i-Pen
3 USB cable
4 Manual and driver CD
5 Hosting bracket
Option List:
1) Long i-pen
Hoisting Operation
1 Metal strap
2 Connection bolt
3 Metal bracket
Nomal Hoisting As shown in left above figure, wrap the metal strap around the
projector steeve and connect with the bolt.
Upside down Hoisting: As shown in right above figure, remove the i Cam screw
firstly. Upsidedown the i Cam. Install the screw again and the other operation is
same with normal hoisting.
Operation Mode
Touching operation: Touch the penpoint on normal board freely.
Touchless operation: Press the penpoint with finger, make sure the penpoint is
visible to i Cam. Well working within a distance 10 cm to the screen or wall.
IV i -Interactor Control Panel Instructions
1.Calibration
Open the i -Interactor Control Panel adjust the i-cam position, and make sure it can
see the entire projection field as shown in following example picture.
Auto Calibration
Note:Please make sure the projection picture full and in the same level,do not block the
projection field when doing calibration.When the system is calibrated ready.Do not mov
e i-Cam or projector.Otherwise,you have to re-calibrate the system.We recommand mo
unt i-Interactor with projector together on the ceiling,it can get better calibration.
Manual Calibration
When the Auto Calibration procedure failed, please use the Manu function instead by
pressing . In this procedure, the projector will display 9 Red points sequentially.
The user is required to click these points centers one by one with the pen. When all the
points have been clicked, the system is calibrated.
If you want to check system debug, please click , the interface of the program will
expand and show the camera picture.
The Status contains: current frame rate, the pens coordinate, status of left mouse key and
the speckle size, etc.
Noteplease click to close the camera picture when system is running, or the
speed of system will be reduced
3. Advanced Settings
Camera Select: If your PC connects with more than one camera, please select the camera
of i Cam.
Exposure Time: Control the exposure time of i Cam. Smaller value gets darker picture
and vice versa. Default value is -6. When the value is changed, re-calibration is required.
Image Flip: The output image of some camera is axisymmetric with the real world scene.
You can flip the image through this combobox and make it correspondent to the scene.
ThresholdAutomatically set, if it needs to be adjusted manually, the suggestion adjust
range is 120-200,default value is 180.
Speckle size (min): Minimum size of the IR speckle size (in pixel) that the system can
detect. Smaller value can improve the system sensitivity but also increases the
possibility of ambient light disturbance. Default value is 5.
Speckle size (max): Maximum size of the IR speckle size (in pixel unit) that the system
can detect. It is designed to filter some big high reflection region. Default value is 1000.
Tolerance: Improving this value can increase the stability of the system, but also
decreases its sensitivity. Default value is 5.
Auto-code: When the pen is pressed down, it will send an authentication code to the i-
Cam, this function is closed in default.
Multi-P: In the Screen Pen software, you can use several i-Pens to draw at the same
time. If you want to do so, click this checkbox.
H-Speed: Some particular i-Cams support the high speed mode, and in this mode, the
frame rate of the camera is set to 60FPS.
W-Cam: Some i-Cams equipped with a wide-range lens, if your i-Cam is such a device,
please check this box to compensate the distortion caused by wide-range lens.
Auto run at startup: when the computer runs, the i-Interactor runs automatically.
directory.
9. Open the soft keyboard.
10. Open the help document.
11. Quit.
VI. FAQ
Condition 1: there is webcam on your own laptop, could not get computer
projection when calibrating.
Solution:
Open i-Interactor control panel, click setting, and choose i-cam from Selecting
camera.
the control panel, press on the screen with i-Pen, it will show .
As the figure shown, when i-Pen works well, you can see there is a thin circle
out of the white point. If not, there is no circle.
(4) Page up and page down keys on i-Pen can not be used.
Exit i-Interactor control panel, unplug the USB cable, wait for 30-60 seconds,
and reconnect to calibrate.
3. Long i-Pen does not work after the success of Auto Calibration
(1) Check that the batteries are correctly installed. As shown in the figure,
positive towards the pointer tip direction to install the battery.
(2) Please press and hold the yellow button on the pen body when writing.