GTP-10

(to be filled in and signed by the tenderer)


GUARANTEED TECHNICAL PARTICULARS AND DETAILS FOR STATION
TRANSFORMER (100KVA, 33/0.433KV)
Sr. Particulars/Details required to be given
No by the tenderer
1. Name of the Manufacturer
2. Normal full load three phase output with
temperature rise as specified in the
Specification.
H.V. Winding (KVA)
L.V. Winding (KVA)
3. Continuous three phase output under
site conditions as specified in the
Specification (after supplying derating
factor, if any)
H.V. Winding (KVA)
L.V. Winding (KVA)
4. Type of cooling and corresponding normal
full load output
H.V. Winding (KVA)
L.V. Winding (KVA)
5. Overload capacity (for 2 hrs) starting from
full load and with temperature as
specified in the Specification (KVA)
6. Normal ratio of transformation
7. Connections : (including vector group
reference No. & symbol
a) High voltage winding
b) Low voltage winding
8. Type of core construction
i) Temperature rise in oil by
thermometer.
ii) Hot spot temperature over Specified
ambient temperature (Deg.C.)
9. Limit for hot spot temperature for which
the transformer is designed (Deg. C)
10. i) Guaranteed no load loss at normal
ratio, rated frequency at 75 Deg. C
average winding temperature KW.
ii) Tolerance, if any applicable to above
11. i) Guaranteed total losses at normal
ratio, rated output rated voltage dated
frequency at 75 Deg. C average
including auxiliary losses at rated
output-KW
ii) Tolerance, if any applicable to above
12 Earthing current and power factor (L.V.
side)
i) At normal voltage and frequency.
ii) At maximum voltage and normal,
frequency (110%)
13. Efficiency at 75% unity P.F.
i)on 100% load (%)
ii)on 75% load (%)
iii)on 50% load (%)
iv) on 25% load (%)
14. Efficiency at 75 Deg. C. 0.8. p.f., (Lag)
i) on 100% load (%)
ii) on 75% load (%
iii) on 50% Load (%)
v) on 25% load (%)
15. Load at which maximum efficiency occurs
(% of full load)
16. Maximum efficiency (%)
17. a) Percentage reactance at rated current
and frequency (%)
b) Percentage impedance at rated
current and frequency at 75%
i. Positive sequence (%)
ii. Zero sequence (%)
c) Range of variation +/- offered in items
of clause 1.17
d) Tolerance, applicable if any.
18. Impedance voltage drop at normal ratio
at 75 Deg. C expressed voltage on full
load (%)
19. Regulation on full load at unity p.f. at 75
Deg.C expressed as a percentage of
normal voltage (%)
20. Regulation on full load at 0-8 p.f. lagging
at 750 C expressed as a percentage of
normal voltage (%).
21. Maximum current density in the winding:-
i) H.V. (Amps/Sq.cm.)
ii) L.V. (Amps/Sq.cm.)
22. Minimum flux density in the core
(Lines/Sq.c.m.)
23. Core joints (butt or interleaved)
24. Type of winding
i) H.V.
ii) L.V.
25. Type of radial supports
i) H.V. winding
ii) L.V. winding
26. Insulation of higher voltage winding
27. Insulation of lower voltage winding
28. Insulation of core bolts
29. Insulation of core bolts washers
30. Insulation of core and plates

31. Insulation of core Laminations


32. Thickness of transformer tank plates
i) Sides (mm)
ii) Bottom (mm)
iii) Cover (mm)
iv) Tube radiators (mm)
33. Test Voltages
A. Power frequency High voltage Test
i) Test voltage for l min with
stand test on line end of high
voltage winding (KVRMS)
ii) Test voltage for l1 min,
withstand test on neutral end of
the high voltage winding (KVRMS)

iii) Test voltage or 1 min.


withstand test on both line and
neutral ends of low voltage
winding (KVRMS)
B. Impulse Tests:
i) Test voltage for 1.2/50 micro
second full wave withstand
test on huge voltage winding
( KV crest)

ii) Test voltage for 1.2/50 micro


second full wave withstand
test on high voltage
winding(KV crest)
34. Inter-turn Insulation
i) Extent of end turns reinforcement
(%)
ii) Extent of reinforcement of turns
adjacent to tapings (%)
iii) Test voltage for 1 min. 50 HZ
inter-turn insulation test on
(i) (above) (KV RMS)
iv) Test voltage for 1 min. 50 HZ.
Inter-turn insulation test on (ii)
above(KV RMS)
V) Test voltage for 1 min. 50 HZ.
Inter-turn insulation test on main
body of the winding (KV RMS)
35. Type of winding temperature indication.
36. Maximum continuous ratings
i)at 50C ambient air temp. at site
(KVA)
ii)at 40C ambient air temp. at site
(KVA)
iii)at 30C ambient air temperature at
site (KVA)
iv) at 25C ambient air temp. at site
(KVA)
37. Power taken by heater in conservator
tank in watts at 240 volts single phase or
at 400 volts, three phase.
38. Width of track gauge (meters)
39. Bushing Particulars
i) Type of high voltage bushing and
creepage distance in mm.
ii) Weight of high voltage bushing in kgs.
iii) Quantity of oil in one high voltage
bushing insulator in liters
iv) Dry 1 min. power frequency
withstand test voltage value of high
voltage bushing in KV.
v) Wet 10 second power frequency test
voltage value of high voltage
bushing in KV
vi) Impulse withstand test voltage value
with 1.2/50 micro second full wave
of high voltage bushing in KV
vii)Type of low voltage bushing and
creepage distance in mm.

viii) Weight of low voltage bushing


insulator in Kgs.
ix) Quantity of oil in one low voltage
bushing insulator in liters.
x)Dry 1 min-power frequency withstand
test voltage value of low voltage
bushing in KV
xi) Wet 10 second power frequency
withstand test voltage value of
low voltage bushing in KV
xii) Impulse withstands test voltage value
with 1.2/50 micro second full wave
of low voltage bushing in KV.
Xiii) Whether the bushing are
hermetically sealed or not.
40. Clearances
a) Minimum clearances between phases
(mm)
i) In oil
ii) Out of oil
b) Minimum clearances high voltage to
earth in oil (mm)
c) Minimum clearance high voltage to
tank in oil (mm)
41. Net weight of the core (Kgs.)
42. Net weight of copper:-
a) HV (Kgs)
b)LV (Kgs)
c) Total (Kgs)
43. Weight of core and windings(Kgs)
44. Weight of fittings and parts detached for
transport (Kgs.)
45. Net un tanking weight (Kgs)
46. Weight of tank and cover (Kgs)
47. Weight of tank and cover (Kgs)
48. Weight of oil in transformer (including
bushings) (Kgs)
49. Weight of complete transformer with all
fittings and oil (Kgs.)
50. Weight of complete transformer with all
fittings but without oil (Kgs.)
51. Weight of the heaviest shipment package
(Kgs)l and dimensions
52. Dimensions of the transform
i) Maximum height to top of bushings (mm)
iii) Overall length (mm)
iv) Overall width (mm)
53. Minimum clear height for lifting core and winding from tank
in meters.
54. Any other particulars which need a mention.
55 Colour & Marking as per clause 23.0 &
24.0 resp. of chapter 3 in Tech. spec.

Place: Signature
Date: Name
Status
Whether authorized attorney
of the Tendering Company